Solenoid Valve Replacement for 1030/1031 Compressor INTRODUCTION KEISER CORPORATION has always taken pride in designing and engineering the highest quality equipment on the market. This means that you will receive years of low maintenance and minimal repairs from every one of our machines.
10-5508 Rev A Service Department (800) 888-7009 2 Solenoid Valve Replacement for 1030/1031 Compressor * WARNING: Unplug compressor before beginning. Before replacing valve, draw all of the air out of the compressor by pressing both the + and – buttons on the exercise equipment.
10-5508 Rev A Service Department (800) 888-7009 3 Step Two: Remove hoses After the screws have been removed, take the ½ inch open-ended wrench, and loosen the nut that connects the hose to the valve by turning it counter-clockwise, and remove the hose.
10-5508 Rev A Service Department (800) 888-7009 4 Next, remove the lid to the computer control system box by unscrewing the screw on either side. remove two screws on lid Then remove the rubber grommet by using the needle nose pliers to carefully pop it out of the hole.
10-5508 Rev A Service Department (800) 888-7009 5 1030 Circuit Board Diagrams Rev A, B, C Rev D - Current.
10-5508 Rev A Service Department (800) 888-7009 6 push on board, pull on wire Pull each of the four wires back out the hole one by one. Save the rubber grommet.
10-5508 Rev A Service Department (800) 888-7009 7 Step One: Adjust and mount new valve First, make sure that the valve is open. Try to turn the pet-cock on the valve counter- clockwise. If you cannot turn it further counter-clockwise, it is open. open valve counter-clockwise The new valve allows you to rotate its housing for easy mounting.
10-5508 Rev A Service Department (800) 888-7009 8 Next, remove the compression nut that connects the hose to the valve. Replace it with the original compression nut, attach the hose, and tighten the compression nut finger tight. Take the ½ inch wrench and rotate the nut ½ to ¾ turn.
10-5508 Rev A Service Department (800) 888-7009 9 Left side valve Right side valve Repeat the process under Step One to mount the second valve. Step Two: Install single to double adapter and electrical wires Take all four electrical wires and insert them, one by one, through the rubber grommet, and then through the hole.
10-5508 Rev A Service Department (800) 888-7009 10 Step Two: Install single to double adapter and electrical wires Take all four electrical wires and insert them, one by one, through the rubber grommet, and then through the hole. Pull all of the slack into the computer system control box.
10-5508 Rev A Service Department (800) 888-7009 11 Take the single to double adapter and turn it so that the two top prongs are pointing to the left hand side of the box. The bent portion with these two prongs should be over the fuse. Replace the connector with the single to double adapter in L1.
10-5508 Rev A Service Department (800) 888-7009 12 Step Three: Secure and tie wires and replace lid Make sure that all of the slack is inside the computer control system box. Use a zip tie to bind the wires and hoses on the outside of the box. Use the wire cutters to cut off the excess.
10-5508 Rev A Service Department (800) 888-7009 13 feel for air flow After the flow of air has stopped, wait thirty seconds. Slowly lower the air in the compressor to approximately 95 PSI and the compressor should start. Open the valve by turning the handle counter-clockwise to allow the air to reach the equipment.
10-5508 Rev A Service Department (800) 888-7009 14 2470 S. Cherry Ave. Fresno, CA 93706 1(800) 888-7009 Fax: (559 )256-8100 e-mail: info@keiser.com www.
Een belangrijk punt na aankoop van elk apparaat Keiser 1030 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Keiser 1030 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Keiser 1030 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Keiser 1030 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Keiser 1030 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Keiser 1030 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Keiser 1030 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Keiser 1030 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.