Part Number 900-448 Revision A September 2006 UDS2100 User Guide.
UDS2100 User Guide 2 Copyright & Trademark © 2006, Lantronix. All rights reserved. No par t of the contents of this book may b e transmitted or reproduced in any form or by any means without the written permissi on of Lantronix. Printed in the United States of America.
UDS2100 User Guide 3 Contents 1: Using This Guide 7 Purpose and Audience _______________________________________________ 7 Chapter Summary ___________________________________________________ 7 Additio.
UDS2100 User Guide 4 Serial Port Connection ___________________________________________ 36 Exiting Setup Mode _________________________________________________ 37 6: Setup Mode: Server Configuration 3.
UDS2100 User Guide 5 Disable TFTP Firmware Up date ____________________________________ 58 Disable Port 77FE (Hex) __________________________________________ 58 Disable Web Server ____________________.
UDS2100 User Guide 6 D: Compliance and Disclaimer 81 Index 83 Figures Figure 2-1. Serial Tunneling Example _____________________________________ 10 Figure 2-2. Direct TCP/IP or Redirector Configuratio n ________________________ 10 Figure 2-3. Sample Hardware Address ____________________________________ 12 Figure 3-1.
UDS2100 User Guide 7 1 1 : : U U s s i i n n g g T T h h i i s s G G u u i i d d e e Purpose and Audience This guide provides the informatio n needed to configure, use, and update the UDS2100 device se rver. It is for system administrators and those responsible fo r installing and maintaining the UDS.
1: Using This Guide UDS2100 User Guide 8 Chapter Description 13: Technical Specifications Lists technical specifications for th e UDS. A: Alternative Ways to Assi g n an IP Address Provides detailed informati on about using DHCP, AutoIP, BOOTP ARP, and Telnet to assign an IP address.
UDS2100 User Guide 9 2 2 : : I I n n t t r r o o d d u u c c t t i i o o n n The UDS2100 is a 2-port device server that provide s a quick, simple, and cost- effective way to bring the advantages of data accessibility and remo te management to devices not currently connected to a network.
2: Introduction UDS2100 User Guide 10 Figure 2-1. Serial Tunneling Example The Com Port Redirector software inclu ded on the product CD sim plifies the integration process by extending the fu nctionality of COM-port-based Win dows™ applications.
2: Introduction UDS2100 User Guide 11 Protocol Support The UDS uses the Internet Protocol (IP) for network communications and the Transmission Control Protocol (TCP ) to assu re that no data is lost or duplicated and that everything sent to the connection arrives correctly at the target.
2: Introduction UDS2100 User Guide 12 Product Information Label The product information label on the under side of the unit contains the following information about your specific unit: Bar code .
UDS2100 User Guide 13 3 3 : : G G e e t t t t i i n n g g S S t t a a r r t t e e d d This chapter describe s how to get your UDS up and running in the shortest possible time. Package Contents Verify and inspect the contents of the UD S2100 package using the following li st.
3: Getting Started UDS2100 User Guide 14 Installing the UDS Figure 3-1. UDS2100 Conn ected to Serial Device and Netwo rk To install the unit: To install the unit, complete the following steps in ord er. Refer to the numbers in the previous figure. 1. Connect a serial device to your unit.
3: Getting Started UDS2100 User Guide 15 Required Information Before configuring the UDS, have t he following information available: Hardware Address Take note of the unit’s hardware addre ss (also known as the Ethernet or MAC address).
3: Getting Started UDS2100 User Guide 16 Assigning the IP Address: DeviceInstaller This chapter covers the steps for getti ng the UDS2100 device server online and for viewing its current configuration. Note: DeviceInstaller onlin e Help provides more detai led inform ation on using DeviceI nstaller.
3: Getting Started UDS2100 User Guide 17 7. Select the device from the main window list and select Ping from the Tools menu. The Ping Device dialog box shows the IP address of the selected u nit. 8. From the Tools menu, click the Ping button. The results display in the Status window.
3: Getting Started UDS2100 User Guide 18 Table 3-1. Current Configura tion Setting Description Name Configurable field. A name that identifies the UDS21 00. Double-click the field, type in the value, and press Enter to complete. This name is not v isible on other PCs or laptops using Dev iceInstaller.
3: Getting Started UDS2100 User Guide 19 Setting Description Gateway Displays the UDS2100’s current gatew ay. To change the gateway, see Assigning an IP Address on page 16. Number of Ports Displays 2, the number of ports on th e UDS2100. TCP Keepalive Displays the UDS2100’s TCP keepali ve value.
3: Getting Started UDS2100 User Guide 20 3. Continue with step 4 in 5: Configuration via Telnet o r Serial Port (S etup Mode) . Assigning the IP Address: Serial Port Login To assign the IP address and other net work settings using a serial connection : 1.
UDS2100 User Guide 21 4 4 : : C C o o n n f f i i g g u u r r a a t t i i o o n n U U s s i i n n g g W W e e b b M M a a n n a a g g e e r r You must configure the unit so it can communi cate on a network with your serial device.
4: Configuration Using Web Manag er UDS2100 User Guide 22 Figure 4-1. Lantronix Web Manager The main menu is in the left pane of the Web Manage r window. Network Configuration The unit’s network values display when you sel ect Network from the main menu.
4: Configuration Using Web Manag er UDS2100 User Guide 23 Figure 4-2. Netw o rk Settings Automatic IP Address Configuration An IP address can be assigned automat ically. You then enter related network settings. To assign an IP address automatically : 1.
4: Configuration Using Web Manag er UDS2100 User Guide 24 4. When you are finished, click the OK button. 5. On the main menu, click Apply Settings . Static IP Address Configuration You can manually assign an IP address to the unit and enter related network settings.
4: Configuration Using Web Manag er UDS2100 User Guide 25 Server Configuration The unit’s server values display when you sele ct Server from the main menu. The following sections descri be the configurable parameters on th e Server Settings page. Figure 4-3.
4: Configuration Using Web Manag er UDS2100 User Guide 26 Monitor Mode @ Bootup Select Disable to disa ble entry into the mo nitor mode using the yyy or xx1 key se q uence at startup.
4: Configuration Using Web Manag er UDS2100 User Guide 27 Figure 4-4. Hostlist Settings 2. Enter or modify the following fields: Retry Settings Retry Counter Enter the v alue for the number of times the UDS2 100 should attempt to retry connecting to the host list.
4: Configuration Using Web Manag er UDS2100 User Guide 28 Figure 4-5. Channel Se rial Settings 2. In the available fields, enter the following information: Channel 1 Disable Serial Port When selected , disables communication through the serial port. The serial port is enabled by de fault.
4: Configuration Using Web Manag er UDS2100 User Guide 29 Stop Bits The stop bit follo ws the data and parity bits in seria l communication. It ind icates the end of transmission. The default setting is 1. Pack Control Enable Packing Select to enable packing on the UDS21 00.
4: Configuration Using Web Manag er UDS2100 User Guide 30 Flush Output Buffer (N et work to Seri al) With Active Connect Select Yes to clear the ou tput buffer with a connection that is initiated from the dev i ce to the network. The default setting is No.
4: Configuration Using Web Manag er UDS2100 User Guide 31 2. In the available fields, enter or modify the following information: Connect Protocol Protocol From the drop-down menu, se lect TCP. Connect Mode: Passive Connection Accept Incoming Select Yes to accept incoming co nnections.
4: Configuration Using Web Manag er UDS2100 User Guide 32 by default. Remote Port Enter the remote port number. Remote Host Enter the IP add ress o f th e remote device. Common Options Telnet Mode This field is a vailable for config uration only when Active Connect is set to None.
4: Configuration Using Web Manag er UDS2100 User Guide 33 3. When you are finished, click the OK button. 4. On the main menu, click Apply Settings . Connection Settings - UDP To configure a channel’s UDP settin gs: 1. On the main menu, click Connection .
4: Configuration Using Web Manag er UDS2100 User Guide 34 Accept Incoming Select Yes to accept incoming UDP d atagram s. T he default setting is Yes. Endpoint Configuration Local Port Enter the local port number. Remote Port Enter the port num ber of the remote device.
UDS2100 User Guide 35 5 5 : : C C o o n n f f i i g g u u r r a a t t i i o o n n v v i i a a T T e e l l n n e e t t o o r r S S e e r r i i a a l l P P o o r r t t ( ( S S e e t t u u p p M M o o d d e e ) ) You must configure the unit so it can communi cate on a network with your serial device.
5: Configuration via Telnet or Serial Port (Setup Mode) UDS2100 User Guide 36 To establish a Telnet connection: 1. From the Windows Start menu, click Run and type the following command, where x.x.x.x is the IP address, and 9999 is the unit’s fixed network configuration port number: Windows: telnet x.
5: Configuration via Telnet or Serial Port (Setup Mode) UDS2100 User Guide 37 Exiting Setup Mode To exit setup mode: You have two options: To save all changes and reboot the device, sel ect option 9 Save and exit from the Change Setup menu. All values are stored in nonvolatile memo ry.
UDS2100 User Guide 38 6 6 : : S S e e t t u u p p M M o o d d e e : : S S e e r r v v e e r r C C o o n n f f i i g g u u r r a a t t i i o o n n This chapter explains how to configure the network settings. Note: Current values display in parenth eses.
6: Setup Mode: Server Configuration UDS2100 User Guide 39 default setting is N (No), meaning the gateway address has not been set. To set the gateway address, type Y and enter the address.
6: Setup Mode: Server Configuration UDS2100 User Guide 40 There are three methods for assi gning DHCP names to the unit. Default DHCP Name : If you do not change the DHCP name, and you are using an IP of 0.0.0.0, then the DHCP name defaults to XX.
UDS2100 User Guide 41 7 7 : : S S e e t t u u p p M M o o d d e e : : C C h h a a n n n n e e l l C C o o n n f f i i g g u u r r a a t t i i o o n n This chapter explains how to configu re the serial ports. Notes: Current valu es display in par enthesis.
7: Setup Mode: Channel Configuration UDS2100 User Guide 42 I/F (Interface) Mode The Interface (I/F) Mode is a bit-coded byte entered in hexadecimal notation.
7: Setup Mode: Channel Configuration UDS2100 User Guide 43 Use the following table to select flow control option s: Table 7-3. Flo w Control Opt ions Flow Control Option Hex No flow control 00 XON/XOF.
7: Setup Mode: Channel Configuration UDS2100 User Guide 44 Table 7-5. Connect Mod e Op tion s Connect Mode Option 7 6 5 4 3 2 1 0 a) Incoming Connection Never accept incoming 0 0 0 Accept wi th DTR Ac.
7: Setup Mode: Channel Configuration UDS2100 User Guide 45 a) Incoming Connection Never Accept Incoming Rejects all external conn ectio n attempts. Accept with DTR Active Accepts external con nection requests only when the DT R input is asserted. Cannot be used with Modem Mode.
7: Setup Mode: Channel Configuration UDS2100 User Guide 46 If a partial IP address is presented in a command string, it is interpreted to be the least significant bytes of th e IP add ress and uses the internally stored remo te IP address to provide the most significant bytes of the IP address.
7: Setup Mode: Channel Configuration UDS2100 User Guide 47 Figure 4-7. Hostlist Option To enable the hostlist: 1. Enter a Connect Mode of 0x20 ( 2 X), where X is 1-5. 1=sta rt with any character, 2=with active DTR, 3=with carriage re turn, 4=manual connection, 5=autos tart.
7: Setup Mode: Channel Configuration UDS2100 User Guide 48 e) Modem Mode In Modem (Emulation) Mode, the unit presents a mod em interface to the attached serial device. It accepts AT-style mode m comma nds and handle s the modem signals correctly. Normally, there is a modem connected to a local PC and a modem connected to a remote machine.
7: Setup Mode: Channel Configuration UDS2100 User Guide 49 Table 4-11. Modem Mod e Mess ages Message Meaning Full Verbose OK Command was executed w ithout error. CONNECT A network connection has been established. NO CARRIER A network connection has been closed.
7: Setup Mode: Channel Configuration UDS2100 User Guide 50 Table 7-6. Modem Mode Co mmands Modem Mode Command Function ATDTx.x.x.x,pppp or ATDTx.x.x.x/pppp Makes a connection to an IP ad dress (x.x.x.x) and a remote port number (pppp). ATDTx.x.x.x Makes a connection to an IP ad d ress (x.
7: Setup Mode: Channel Configuration UDS2100 User Guide 51 Remote IP Address This is the destination IP addres s used with an outgo ing connection. Remote IP Address : (000) (000) (000) (000)_ Note: This option does not displ ay when Hostlist is enabled from the ConnectMode prom pt (see Connect Mo de on page 43 for more information).
7: Setup Mode: Channel Configuration UDS2100 User Guide 52 (3) The TCP connection closes even if the remote site does not acknowledge the disconnection. (4) When there is a network connection to or fr o m the serial port, the state LED turns off instead of blinking.
7: Setup Mode: Channel Configuration UDS2100 User Guide 53 Note: All bit positions in the table that ar e blank represent “don’ t care” bits for that particular option, which can be set to either a 0 or 1 valu e.
7: Setup Mode: Channel Configuration UDS2100 User Guide 54 DisConnTime (Inactivity Timeout) Use this parameter to set an inactivity ti meout. The unit drops the connection if there is no activity on the serial line before the se t time expires. Enter time in the format mm:ss, where m is the number of minutes an d s is the number of seconds.
UDS2100 User Guide 55 8 8 : : S S e e t t u u p p M M o o d d e e : : A A d d v v a a n n c c e e d d S S e e t t t t i i n n g g s s Expert Settings (Option 5) Note: You can change the se settings using Telnet or serial conne ctions only, not on the Web Manager.
8: Setup Mode: Advanced Settings UDS2100 User Guide 56 ARP Cache timeout in seconds Whenever the unit communicate s with another device on the network, it adds an entry into its ARP table. The ARP Cache timeout option allows you to define ho w many seconds (1-600) the unit will wait bef ore timing out this table.
8: Setup Mode: Advanced Settings UDS2100 User Guide 57 Security Settings (Option 6) You can change secu rity settings by means of Telnet or serial conn ections only, not on the Web Manager. We reco mmend that you set security over the dedicated network or over the serial setup to preve nt eavesdropping.
8: Setup Mode: Advanced Settings UDS2100 User Guide 58 Disable TFTP Firmware Update This setting defaults to the N (No) option. The Y (Yes) option disables the use of TFTP to perform network firmware u pgrades. With this option, you can d ownload firmware upgrades over the serial p ort using DeviceIns taller’s Recover Firm ware procedure.
8: Setup Mode: Advanced Settings UDS2100 User Guide 59 Default Settings (Option 7) Select 7 to reset the unit’s Channel 1 co nfiguration and expert settings to the def ault settings. The server configuration setting s for IP address, gateway IP address, and netmask remain unchanged.
8: Setup Mode: Advanced Settings UDS2100 User Guide 60 Disable Web Setup No Disable ECHO ports Yes Enable Enhanced Passw ord No.
UDS2100 User Guide 61 9 9 : : F F i i r r m m w w a a r r e e U U p p g g r r a a d d e e s s Obtaining Firmware You can obtain the most up-to-date firmware an d release notes for the unit from the Lantronix web site ( www.lantronix.com ) or by using anonymous FTP ( ftp.
9: Firmware Upgrades UDS2100 User Guide 62 Figure 9-1. TFTP Wi ndow After the firmware has been loaded and stor e d, which takes approximately 8 seconds to complete, the unit performs a power reset. Using TFTP: Command Line Interface To download new firmware from a computer: 1.
9: Firmware Upgrades UDS2100 User Guide 63 5. For Device Model , be su re the appropriate device (e.g., UDS2100) displays. 6. For Firmware File , click the Bro wse button and go to the location where the firmware file resides. Note : Make sure the UDS2100 on whi ch you are recovering firm wa re is connected to this selected port on your PC.
UDS2100 User Guide 64 1 1 0 0 : : M M o o n n i i t t o o r r M M o o d d e e Monitor Mode is a command-line inte rface used for diagno stic purposes. There are two ways to enter Monitor Mode: locally using the seri al port or remotely using the network.
10: Monitor Mode UDS2100 User Guide 65 Table 10-1. Monitor Mode Commands Command Command Name Function VS x.x.x.x Version Queries software header reco rd (16 bytes) of unit with IP address x.x. x.x. GC x.x.x.x Get Configuration Gets configura tion of unit with IP address x.
UDS2100 User Guide 66 1 1 1 1 : : T T r r o o u u b b l l e e s s h h o o o o t t i i n n g g a a n n d d C C o o n n t t a a c c t t I I n n f f o o r r m m a a t t i i o o n n This chapter discusses ho w you can diagnose and fix erro rs quickly without having to contact a dealer or Lantronix.
11: Troubleshooting and Contact Information UDS2100 User Guide 67 Figure 11-1. Diagnos tic, Power, and Serial Port LEDs Table 11-1. UDS2100 LEDs LEDs Meaning Power/Diagnostic (Blue) Steady On = Power .
11: Troubleshooting and Contact Information UDS2100 User Guide 68 Problems and Error Messages Table 11-2. Problems an d Error Messages Problem/Message Reason Solution When you issue the ARP –S command in W indows, the " ARP entry addition failed: 5" message displays.
11: Troubleshooting and Contact Information UDS2100 User Guide 69 Problem/Message Reason Solution When you try to assign an IP with DeviceInstaller, you get the following : "No response from dev ice! Verify the IP, Hardware Address and Netwo rk Class.
11: Troubleshooting and Contact Information UDS2100 User Guide 70 Problem/Message Reason Solution The device ser ver appear s to be set up correctly , but you are not communicating with y our device attached to the de vice ser ver across the netw ork.
UDS2100 User Guide 71 1 1 2 2 : : C C o o n n n n e e c c t t i i o o n n s s a a n n d d P P i i n n o o u u t t s s UDS2100 Serial Ports The UDS2100 has two male DB9 DTE serial ports that suppo rt RS-232C/RS-422 (4- wire)/RS-485 (2-wire) serial standards up to 230 Kbps (and up to 921 Kbps if high performance i s selected).
12: Connections and Pinouts UDS2100 User Guide 72 Network Port The unit's back panel cont ains a 9-30VDC power plu g and an RJ45 (10/100) Ethernet port. Figure 12-3. Netw ork Interface Reset Button You can reset the unit to factory defaults, including cle aring the network settings (IP address, gateway, and netmask are set to 00s).
UDS2100 User Guide 73 1 1 3 3 : : T T e e c c h h n n i i c c a a l l S S p p e e c c i i f f i i c c a a t t i i o o n n s s Table 13-1. UDS2100 Tech nical Specifications Category Description CPU Lan.
13: Technical Specifications UDS2100 User Guide 74 Category Description Installable Industrial Protocols ModBus TCP, ModBus ASCII/RTU, DF1 Multi-Master (IAP version only) Management Internal web serve.
13: Technical Specifications UDS2100 User Guide 75 Category Description transient over voltages Ethernet Port: 1500 VAC isolation shielded with shield connecte d to chassis ground for signal integrity.
UDS2100 User Guide 76 A A : : A A l l t t e e r r n n a a t t i i v v e e W W a a y y s s t t o o A A s s s s i i g g n n a a n n I I P P A A d d d d r r e e s s s s Earlier chapters describe how to a ssign a static IP address usin g DeviceInstaller, Web Manager, and Setup Mode (th rough a Telnet or serial co nnection).
A: Alternative Ways to Assign an IP Address UDS2100 User Guide 77 BOOTP Similar to DHCP, but for smaller networks. Automatically assign s the IP address for a specific duration of time.
UDS2100 User Guide 78 B B : : B B i i n n a a r r y y t t o o H H e e x x a a d d e e c c i i m m a a l l C C o o n n v v e e r r s s i i o o n n s s Many of the unit’s configuration procedures require a ssembling a series of options (represented as bits) into a complete co mmand (represented as a byte).
B: Binary to He xad ecimal Conve rsi ons UDS2100 User Guide 79 Scientific Calculator Another simple way to convert bina ry to hex adecimals is to use a scientific calcula tor, such as the one available on Win dow s’ operating systems. For example: 1.
UDS2100 User Guide 80 C C : : W W a a r r r r a a n n t t y y Lantronix warrants each Lantronix product to be free from defe cts in material and workmanship for a period of TWO YEARS after the date of shipm ent.
UDS2100 User Guide 81 D D : : C C o o m m p p l l i i a a n n c c e e a a n n d d D D i i s s c c l l a a i i m m e e r r Manufacturer’s Name & Address Lantronix 15353 Barranca Parkway, Irvine, .
D:Compliance and Disclai mer UDS2100 User Guide 82 Disclaimer and Supplementary Information This product has been designed to com ply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against such interference when operating i n a commercial environment.
UDS2100 User Guide 83 Index Applications, 9 ARP and Telnet, 77 AutoIP, 15, 76 Binary to hexadecimal conversions, 78 BOOTP, 15, 77 Channel settings , 41 Command line interface, 35 Configuration methods.
Een belangrijk punt na aankoop van elk apparaat Lantronix UDS2100 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Lantronix UDS2100 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Lantronix UDS2100 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Lantronix UDS2100 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Lantronix UDS2100 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Lantronix UDS2100 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Lantronix UDS2100 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Lantronix UDS2100 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.