Report No. 050-S-15c-5 INST ALLA TION AND OPERA TION MANUAL Direct-V ent Gas Fireplace Inserts Retain These Instructions For Future Reference W ARNINGS • Hot! Do not touch! The glass and surfaces of this appliance will be hot during operation and will retain heat for a while after shutting off the appliance.
2 C autions & s afety FOR YOUR SAFETY do not install or operate your Ravenna™ gas insert without first reading & under - standing this manual. Any installation or operation of the appliance deviating from that which is stated in this manual WILL void the warranty & may be hazardous.
3 T able of Contents C autions & s afety ..................................................................................... 2 o rifiCe s ize / a l titude a djustment .................................................................... 4 f ireplaCe r equirements .
4 Orifice Size/Altitude Adjustment For altitudes above 2,000 feet (In Canada 4,500 FT/1370 M),the orifice should be de-rated by 4% for ever y 1,000 feet to maintain the proper ratio of gas to air . Improper orifice sizing may result in damage and unsafe conditions.
5 Inspection The state or local gas inspector of the side wall horizontally vented gas fuel ed equi pme nt shal l not app rove the insta lla tion unless, upon ins pect ion, the inspector obser ves carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.
6 Pre-Installation f ea tures Installation Options Manufactured (Mobile) Home Natural Gas Or Propane (LP) Bedrooms Optional Wall-mounted Or Remote Thermostat Electrical The standard fan motor requires 120 Volts AC for operation. The fireplace is not dependent on the fan or an outside elec - trical supply to operate.
7 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. i nsert d imensions m inimum f ireplaCe o pening r equired A = 29-3/4” (756mm) Front Opening B = 19-1/2” (495mm) Height C = 19” (483mm) Rear Width D = 16” (406mm) Fireplace Depth * T op air duct will need to be removed for short ZC applica - tions.
8 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Note: Hearth protection to be min. 3/8” (10mm) thick non- combustible or equivalent, with a k factor of .84. i nsert l eveling At each front and rear corner of the insert is an adjustable leg provided to level the insert should the hearth of the fireplace be uneven.
9 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. v ertiCal v enting The vent pipes must be connected to the proper collars on the unit and the exhaust vent pipe must be connected to the termination cap or the unit will not operate. The combustion air vent pipe can be connected to the termination cap or it can terminate inside the chimney .
10 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. z ero C learanCe f ireplaCe i nst allation This insert may be installed in a masonr y or factor y built/zero clearance (ZC) fireplace. When installing in a ZC fireplace, the ZC grate must be removed and the ZC damper must be removed or secured open.
11 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 4. Install a light layer of rockwool directly over the ports. - A light layer will give a more constant rear flame. - A heavy layer will give more glow , but will need to be adjusted after light up.
12 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Gas Line Installation After leveling, position the insert in the fireplace - holding it about six inches out from its final location. Caution: Specific hearth requirements apply (see Clear - ances to Combustibles).
13 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Operating Instructions p re -l ighting C heCklist Be sure to check these items before the initial lighting of the insert: c The insert gas label corresponds to the gas supply avail- able - that is "natural gas" for natural gas or "LP gas" for LP gas.
14 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. W ARNINGS • Improper installation, adjustment, alteration, service or maintenance can cause injur y or property damage. For assistance or additional infor mati on, consult a qualifi ed installer , service agency or your gas supplier .
15 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Flame Color & Behavior Y our Ravenna™ gas insert is designed for maximum heat- ing efficiency . Therefore, upon lighting of the main burner the flames will be semi-transparent or “bluish.
16 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. o pera ting o ptions The rocker switch on your Ravenna™ gas insert is used to turn the burner on and off while the pilot is on. The rocker switch can be installed in the hole in the right side of the top surround panel or in the hole in the panel to the left of the igniter button.
17 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Maintenance & Ser vicing m aintenanCe C heCklist The following should only be performed by a qualified service technician. Caution: Label all wires prior to disconnection when servicing controls.
18 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Fan Snap Switch Fan Speed Control White Ground (Green) Black Blower Black (Hot) White (Neutral) Power Source Blower Wiring Schematic g lass d oor r emov al Caution: Do not slam or strike glass door or damage may occur .
19 SYMPTOM PROBABLE CAUSE CORRECTIVE ACTION Thin black coating (soot) forms on the viewing glass, logs, or firebox Improper log or ember placement Improper air shutter setting Not enough combus- tion air See Brick Panel and Log Set Installation on Pages 10 & 11 .
20 Replacement Parts Ravenna™ 33/40 (RDV33/40) Part Number Description H3132 Cassette Assembly NG 33,000 BTU (if LP , also requires H5433 Conversion Kit) H3045 Cassette Assembly NG 40,000 BTU (if LP.
21 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Fi nis h P ane l s / fr ont Su ppo rts Ca t. No. De scr ipt ion 75 2 5 2 "Z C L o w er F in i s h P a ne l /B ay F ac e Su p p or t *R e q.
22 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. MINIMUM CLEARANCES TO COMBUSTIBLES RDV40 RDV33 E = T op Facing to Bottom of Insert 35.5”(902mm) 31.5”(800mm) F = Cent er of G las s to Si de F aci ng o r S id e W al l 25.5”(648mm) 25.5” (648mm) *J = 10.
23 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. CAUT ION : YOU R CO UNT R Y G AS APPLIA NCE MUS T AL WA YS B E O PER A TE D W ITH GLA SS DOO R IN PL ACE . STO P! Rea d t he s afe ty info rma tio n a bove be for e pr oce edi ng. 1. Ope n t he l owe r d oor .
Printed in U.S.A. © Lennox Hearth Products 2007 P/N 775,218M REV . B 12/2007 Lennox™ reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information.
Een belangrijk punt na aankoop van elk apparaat Lennox RAVENNA RDV33\40 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Lennox RAVENNA RDV33\40 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Lennox RAVENNA RDV33\40 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Lennox RAVENNA RDV33\40 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Lennox RAVENNA RDV33\40 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Lennox RAVENNA RDV33\40 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Lennox RAVENNA RDV33\40 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Lennox RAVENNA RDV33\40 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.