NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 1 36" Wood Burning Fireplaces P/N 850,005M REV. F 01/2007 COL-3629 COL-3629H MODELS RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE WH Report No.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 2 TABLE OF CONTENTS Safety Rules .................................... page 2 Tools and Building Supplies ............ page 2 Precautions ..................................... page 3 Introduction .......
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 3 Figure 1 TYPICAL INSTALLATION *Construction Materials: • framing materials • paneling • particle board • flooring • dry wall • etc. • plywood PRECAUTIONS Note: These fireplace systems are not difficult to install.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 4 Figure 2 LOCATION OF FIREPLACE Carefully select the proper location for heat circulation, aesthetics, chimney obstructions and clearance to side wall(s). With proper pre- planning, a slight adjustment of a few inches can save considerable time and expense later during construction and assembly.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 5 DO NOT permanently place furniture or other items such as decorative pillows within 60" of the fireplace front face. ASSEMBLY STEPS Note: The following steps represent the normal sequence of installation.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 6 Step 3. Refer to fireplace drawings and specifi- cations on pages 6 and 7 for framing dimensions and details.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 7 Note: The framed depth, 28 ¹ ³ ⁄ ₁ ₆ " (732 mm) from a framed wall, must always be measured from a finished surface. If a wall covering such as drywall is to be attached to the rear wall, then the framed depth must be measured from the drywall sur- face.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 8 Step 5. Fireplace should be secured to side framing members using the full length nailing tabs at the top and bottom of the fireplace front face.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 9 Step 4. Note: Chimney sections are constructed with a unique locking tab design, which en- sures an immediate, tight assembly between sections. Plan your chimney requirements care- fully before assembly as chimney is difficult to disassemble after installation.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 10 Locking Band Mastic Roof Ridge 120 ° Step 8. The standard Security Chimneys FTF10 roof flashing assemblies include a storm collar. Slide the storm collar over outer chimney, rest on flashing spacers and align with top surface of flashing.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 11 MULTIPLE TERMINATIONS If more than one termination is located in the same chase or within the same general proxim- ity, we suggest they should be se.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 12 Figure 38 Figure 40 OFFSET CALCULATIONS Step 1. Use Offset Chart to determine amount of horizontal offset (A) and height (B) for various chimney section assemblies.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 13 397 ¹⁄₄ 33 1 ¹⁄₄ 20 1 1 403 ¹⁄₄ 33 7 ¹⁄₄ 11 1 1 411 34 3 0 0 12 421 ¹⁄₄ 35 1 ¹⁄₄ 10 1 2 427 ¹⁄₄ 35 7 ¹⁄₄ 01 .
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 14 Return Elbow Figure 41 Note: The return elbow assembly performs the same function as a stabilizer. Consider this when determining the need for a stabilizer. Note: Do not apply excessive pressure to any subsequent chimney section following return elbow assembly when installing.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 15 Outside combustion air ducting may be run upwards or vertically through framing and ceil- ing joists, with the hood installed through an outside wall and 3' (914 mm) below the termi- nation.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 16 Fireplace Opening T ypical Installation 6 ⁹⁄₁₆ " (167mm) 12" (305mm) Min. Combustible Mantel and T rim Spacer Noncombustible Wall Covering Finished Wall 12" (305mm) Max.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 17 Answer - The minimum required thickness of the Micore 160 is .417”, therefore round up to nearest standard thickness available which is 1/2”.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 18 Locking Band 63L60 FLB Figure 50 FINISH TO YOUR TASTE There are a wide variety of “finished looks” for these fireplaces, from formal wall decor with elaborate mantels to rustic wood paneling or warm brick facings.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 19 63L16 FTF10-12 63L17 FTF10-18 63L18 FTF10-36 62L94 FTF10-18C Chimney Section 62L95 FTF10-36C Storm Collar 63L59 FSC 63L40 F10F6 Flashing 63L41 F10F1.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 20 The manufacturer reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information.
Een belangrijk punt na aankoop van elk apparaat Linksys COL-3629 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Linksys COL-3629 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Linksys COL-3629 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Linksys COL-3629 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Linksys COL-3629 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Linksys COL-3629 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Linksys COL-3629 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Linksys COL-3629 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.