Datalogger ™ DataLogger and DataPulse Software Instruction Manual Febuary 2005 © Copyright 2005 Magnetek.
Impulse DataLogger Series 3 Instruction Manual 2/1/05 1 of 16 ©2005 ELECTROMOTIVE SYSTEMS All rights reserved. This noti ce applies to all copyri ghted mate rials included with this product , including, but not li mited t o, this manual and software embodied wit hin the product.
Impulse DataLogger Series 3 Instruction Manual 2/1/05 2 of 16 Section 1: Overview The DataLogger Series 3 was designed to simplify troubleshooting and provide for detailed operational histories that are necessary for genuine preventive maintenance.
Impulse DataLogger Series 3 Instruction Manual 2/1/05 3 of 16 How data logging works: The DataLogger is a device which polls the Drive via the RS232 CN1 port. Once connected, the logger will r ead the Inverter Status and U1 parameters. From the Inve rter Status, the logger can detect when the drive is running or when a fault or alarm occurs.
Impulse DataLogger Series 3 Instruction Manual 2/1/05 4 of 16 Logging of Run, Fault, Alarm and Trace Data All Data collection is automatic, viewing data is per the various screens, and the roadmap of functions per the diagram on the Menu Navigation on page 6.
Impulse DataLogger Series 3 Instruction Manual 2/1/05 5 of 16 14912, 14920, 14940, 14960, 14961, 14962, 14964, 14965, and 14980. For connection to Series 3 drives, simply replace the keypad with the data logger. The DataLogger will automatically begin logging after a 2 second boot up.
Impulse DataLogger Series 3 Instruction Manual 2/1/05 6 of 16 DATALOGGER MENU NAVIGATION -Main Menu- Monitor Fault History Alarm History Run History Upload from VFD Download from VFD Clear Data Settin.
Impulse DataLogger Series 3 Instruction Manual 2/1/05 7 of 16 The Monitor Mode provides for Real-Time di splay of Inverter operation. It also indicates the total number of Run events, Alarm and Fault events.
Impulse DataLogger Series 3 Instruction Manual 2/1/05 8 of 16 The Fault History provides the data for reviewing recorded faults and information on each fault occurrence. -FAULT HISTORY - Flt: 1 OF 6 Run: 5 Ext Fault S7 01/16/04 02:37 01/28/04 08:44:13 - FAULT HISTORY - U2-03: 030.
Impulse DataLogger Series 3 Instruction Manual 2/1/05 9 of 16 The Alarm History provides the data for reviewing recorded alarms and information on each alarm occurrence. -ALARM HISTORY - Alm: 1 OF 26 Run: 1369 Upper Limit1 Err 01/16/04 15:14 01/28/04 08:44:13 Date & Time: Used to time stamp all history and trace data.
Impulse DataLogger Series 3 Instruction Manual 2/1/05 10 of 16 The Run History provides the data for reviewing information on each time the drive receives a run command or a change in direction. -RUN HISTORY - Run: 220 OF 260 Forward 01/16/04 15:14 Duration: 40 Secs 01/28/04 08:44:13 Date & Time: Used to time stamp all history and trace data.
Impulse DataLogger Series 3 Instruction Manual 2/1/05 11 of 16 Introduction to DataPulse Series 3 software DataPulse is a user friendly, Windows based, DataLogger communication software that will allow the viewing of logger data in a spreadsheet format.
Impulse DataLogger Series 3 Instruction Manual 2/1/05 12 of 16 Navigating DATAPULSE Series 3 MENU Upload data from Datalogger View parameter data View Run data View Alarm data View Fault data Uploadin.
Impulse DataLogger Series 3 Instruction Manual 2/1/05 13 of 16 Viewing parameter sets Selecting the button will display the parameter sets that are stored in the logger. Double click on the parameter set of inte rest and the parameter information is displayed.
Impulse DataLogger Series 3 Instruction Manual 2/1/05 14 of 16 Displaying Drive History Data Selecting the button will display the fault history window. Selecting the button will display the alarm history and selecting the button will display the run history window.
Impulse DataLogger Series 3 Instruction Manual 2/1/05 15 of 16 Select the data that you want to di splay by selecting in the check box..
Impulse DataLogger Series 3 Instruction Manual 2/1/05 16 of 16 PRINTING It is best to print only the desired informati on from the thousands of pieces of data stored in the logger. To edit and print this information, you would save the file as a *.CSV file which is a “comma separated variable” file.
Een belangrijk punt na aankoop van elk apparaat Magnetek Series 3 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Magnetek Series 3 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Magnetek Series 3 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Magnetek Series 3 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Magnetek Series 3 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Magnetek Series 3 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Magnetek Series 3 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Magnetek Series 3 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.