Gebruiksaanwijzing /service van het product Run Indicator Module RIM100 van de fabrikant Maretron
Ga naar pagina of 17
Revision 1.0 Page i ® ® RIM100 Run Indicator Module User’s Manual Revision 1.0 Copyright © 2008 Maretron, LLP All Rights Reserved Maretron, LLP 9014 N.
RIM100 User's Manual Page ii Revision 1.0 Revision History Revision Description 1.0 Original document.
Revision 1.0 Page iii ® ® Table of Contents 1 Introduc tion .................................................................................................................. ......... 1 1.1 Firmware Revi sion ...........................
.
Revision 1.0 Page 1 ® ® 1 Introduction Congratulations on your purchase of the Maretron Run Indicator Module (RIM100). Maretron has designed and built your RIM100 to the hi ghest standards for years of dependable and accurate service.
RIM100 User's Manual Page 2 Revision 1.0 3. Mount the RIM100 (Section 2.3 ) 4. Connect the RIM100 (Section 2.4 ) 5. Configure the RIM100 (Section 2.
Revision 1.0 Page 3 ® ® 2.3 Mounting the RIM100 Attach the RIM100 securely to the vessel usi ng the included stainle ss steel mounting screws or other fasteners as shown in Figure 1 below .
RIM100 User's Manual Figure 2 – NMEA 2000 ® Connector Face Views 2.4.2 Monitored Load Connections The RIM100 monitored load connections are made by connecting to the 12-pin terminal strip on the top of the unit. First, remove the four screws at the co rners of the unit detaching the splash guard from the unit.
® ® WARNING: The voltages present on AC circui ts can cause electrocution. Before making any electrical connections to the RIM100, ensure that power is removed from all AC circuits that will be connected to the RIM100. Only restore AC power after all connections have been made to the RIM100 and the splash guard has been re-installed.
RIM100 User's Manual Power Switch RIM100 Screw Terminals Monitored DC Load + To DC - Breaker Panel Fuse Fuse User-Supplied Components 1 2 5 4 3 6 7 8 9 10 11 12 V1+ V2- V2+ V1- V3+ V3- V4+ V4- V5+ V5- V6+ V6- Figure 4 – DC Load Connection Diagram 2.
Revision 1.0 Page 7 ® ® 2.5.2 Channel #1 - #6 Mode You must configure the RIM100 as to whether a particular ch annel should be enabled. The allowable values for this parameter are as follows: • “Enable” (default) – Use this value if t he channel is being used to monitor a load.
RIM100 User's Manual Page 8 Revision 1.0 • Check the security of the c able connected to the NMEA 2000 ® co nnector, and tighten if necessary. • Check the security of all of the load connections on t he top of the unit and tighten if necessary.
Revision 1.0 Page 9 ® ® 5 Technical Specifications As Maretron is constantly impr oving its products, all specificat ions are subject to change without notice.
RIM100 User's Manual Page 10 Revision 1.0 Environmental Parameter Value IEC 60945 Classification Exposed Degree of Protection IP64 Operating Temperature -25°C to 55°C Storage Temperature -40°C to 70°C Relative Humidity 93%RH @40° per IEC60945-8.
® ® 7 Installation Template Please check the dimensions before using the fo llowing diagram as a template for drilling the mounting holes because the printing proc ess may have distorted the dimensions. Figure 5 – Mounting Surface Template Revision 1.
RIM100 User's Manual Page 12 Revision 1.0 8 Maretron (2 Year) Limited Warranty Maretron warrants the RI M100 to be free from defects in m aterials and workm anship for t wo (2) years from the date of original purchase.
Revision 1.0 Appendix A – NMEA 2000 Interfacing Page A1 ® ® Appendix A – NMEA 2000 ® Interfacing RIM100 NMEA 2000 ® Periodic Data Transmitted PGNs PGN 127501 – Binary Switch Bank Status The .
Een belangrijk punt na aankoop van elk apparaat Maretron Run Indicator Module RIM100 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Maretron Run Indicator Module RIM100 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Maretron Run Indicator Module RIM100 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Maretron Run Indicator Module RIM100 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Maretron Run Indicator Module RIM100 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Maretron Run Indicator Module RIM100 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Maretron Run Indicator Module RIM100 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Maretron Run Indicator Module RIM100 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.