NL
Metz logo
Officiële handleiding

Metz 44 AF-3M

108 pagina's·1.3 MB·Digitale camera·PDF·ENJA
Metz 44 AF-3M
Inhoudsopgave 12 secties 1. Safety instructions · Foreword · 2. Preparing the mecablitz for use · 4. Operating modes of the mecablitz · … TonenVerbergen
Page 1 of the Metz 44 AF-3M user manual — 1. Safety instructions
Pagina 1 · klik om te vergroten
Pagina 1

  • Never place material that is impervious to light in front of, or directly on, the reflector screen. The reflector screen must be perfectly clean when a
  • Never disassemble the flashgun! DANGER: HIGH VOLTAGE! There are no components inside the flashgun that can be repaired by a layman.
  • When taking a series of flash shots at full light output and fast recycling times as provided by NiCad battery operation, make sure to observe an
  • Do not expose the flash unit or battery charger to dripping or splashing water!
  • Protect the flash unit from excessive heat and humidity! Do not store the flash unit in the glove compartment of a car!

flash is fired. The high energy of the flash light will burn the material or

  • Do not touch the reflector screen after a series of flash shots. Danger of burns!

interval of at least 10 minutes after 15 flashes, otherwise the flash unit

  • Quick changes in temperature may cause condensation. Therefore give the flashgun time to acclimatize!
  • The mecablitz may only be used in combination with a camera’s flash unit if the latter can completely be folded out!

damage the reflector screen if this is not observed.

will be overloaded.

However, we recommend that you study these Operating Instructions before-

  • Never fire a flash in the immediate vicinity of the eyes! Flash fired directly in front of the eyes of a person or animal can damage the retina and
  • Exhausted batteries should be immediately removed from the flash unit! Lye leaking out of spent batteries will damage the unit.

It is only natural that you should want to use your flash unit straight away.

This flash unit is compatible with analog Minolta “Dynax” and “Maxxum”

cameras and digital “Dimage” cameras (see Table 1). It cannot be used for

  • Never take flash shots of car, bus or train drivers, or of motorcycle and bicycle riders, whilst they are travelling. They could be blinded by the

We congratulate you on purchasing this flash unit and thank you for your

  • The flash unit is exclusively intended and approved for photographic use!
  • Never fire a flash in the vicinity of flammable gases or liquids (petrol, solvents, etc.)! DANGER OF EXPLOSION!
  • Only use the approved power sources listed in the Operating Instructions!
  • Do not expose batteries to excessive heat, sunshine, fire and the like!

hand to be able to fully exploit and utilize all the capabilities offered.

Please also open the back cover with the illustrations.

lead to severe visual disorders - even blindness!

  • Never throw exhausted batteries on to a fire!

cameras made by other manufacturers.

  • Never recharge dry-cell batteries!

light and cause an accident!

confidence in Metz products.

1. Safety instructions

Foreword

Page 2 of the Metz 44 AF-3M user manual —
Pagina 2 · klik om te vergroten
Pagina 2

Dynax 9xi Dynax 7xi Dynax 5xi Dynax 3xi / 4 Dynax Spxi Dynax 8000i, Maxxum 8700i Dynax 7000i, Maxxum 7700i Dynax 5000i, Maxxum 5700i Dynax 3000i, Maxxum 3700i Vectis S-1 Dimage 7, 7i Dimage 5

  • x x
  • x x

Dynax 7 Dynax 5 Dynax 800si Dynax 700si Dynax 650si Dynax 600si Dynax 505si super, Maxxum XTsi Dynax 505si, Maxxum HTsi Dynax 500si super, Maxxum 500si Dynax 500si, Maxxum 400si Dynax 404si Dynax 303si

  • Dynax 9 / 9 Titan
  • x x
  • x x
  • x x
  • x x
  • = Dedicated function is supported x = Dedicated function is performed by the camera, or must be set on the camera.
Table 1Overview of dedicated functions

Correct exposure confirmation in camera viewfinder

Multi-zone flash metering (preflash metering)

Flash-ready indication in camera viewfinder

Automatic motor zoom reflector control

Manual TTL flash exposure correction

Automatic flash sync speed control

Maximum flash range indication

Programmed auto flash mode

AF measuring beam control

TTL fill-in flash control

Show 7 more labels / short text on this page
Camera type · Second curtain synchronization · Dedicated functions · Triggering control · Wake-up function · TTL flash control · ADI flash control
Page 3 of the Metz 44 AF-3M user manual — 2. Preparing the mecablitz for use
Pagina 3 · klik om te vergroten
Pagina 3

2.2.2 Replacing batteries (Fig. 1) The batteries are exhausted if the recycling time (elapsing from the triggering

of a full-power flash, e.g. in the M mode, to the moment the flash ready indi-

  • Slide the battery compartment cover in the direction of the arrow and fold open.
  • Insert the batteries lengthwise in conformity with the indicated battery symbols and close the battery compartment cover.

that the batteries are of the same brand and type and have the same

destroy the flash unit! Replace all batteries at a time and make sure

2.3 Switching the flash unit on and off The flash unit is switched on with the main switch on top of the battery com-

2.4 Auto-OFF for mecablitz (Fig. 2) To save battery power and prevent inadvertent battery discharge, the meca-

blitz is factory-set to automatically switch-over to standby mode (Auto-OFF),

When loading batteries ensure correct polarity, as indicated by the

symbols in the battery compartment. Mixed up battery poles may

Exhausted batteries must not be thrown in the dustbin! Help protect

To turn off the flash unit push the main switch down to its bottom position.

If your mecablitz is not going to be used for an extended period of

while flash readiness and the LC display are simultaneously switched off,

the environment and dispose of exhausted batteries at the appro-

time, we recommend to switch it off with the main switch and to

partment cover. In the upper „ON“ position, the mecablitz is on.

cator lights up again) exceeds 60 seconds.

  • Turn off the mecablitz by its main switch.

remove the power sources (batteries).

priate collecting points.

approx. 3 minutes after:

  • Firing a flash
  • Switch-on
  • Turn the knurled nut against the mecablitz housing until the stop point is reached. The locking device in the adapter shoe is now fully retracted into the housing.
  • 4 nickel-metal-hydride batteries, type IEC HR6 (size AA). They have a significantly higher capacity than NiCad batteries and are less harmful to the
  • Turn the knurled nut against the camera body as far as possible, thereby clamping the mecablitz.
  • 4 NiCad batteries, type IEC KR 15/51 (KR6, size AA). They permit very fast recycling and are economical in use because they are rechargeable.

Remove the batteries from the mecablitz if it is not going to be used

  • Turn the knurled nut against the mecablitz housing until the stop point is reached.
  • 4 alkaline-manganese dry-cell batteries, type IEC LR6 (size AA/AM3). Maintenance-free power source for moderate power requirements.
  • 4 lithium batteries, type IEC FR6 L91 (size AA). Maintenance-free highcapacity power source with a low self-discharge rate.
  • Slide the mecablitz foot completely into the cameras’s accessory shoe.

2.1.1 Mounting the mecablitz on the camera Turn off the camera and the mecablitz by their main switch!

2.1.2 Removing the mecablitz from the camera Turn off the camera and the mecablitz by their main switch!

2.2.1 Suitable batteries The mecablitz can be operated with any of the following batteries:

  • Withdraw the mecablitz from the camera’s accessory shoe.

2. Preparing the mecablitz for use

for an extended period of time.

2.1 Mounting the mecablitz

environment (no cadmium).

2.2 Power supply

capacity!

Page 4 of the Metz 44 AF-3M user manual —
Pagina 4 · klik om te vergroten
Pagina 4

tronic control circuit within the camera transmits a stop signal to the mecablitz

instantly interrupting the flash. The advantage of this flash mode is that all fac-

focal length with zoom lenses, extensions for close-ups, etc.) are automatically

nic system automatically determines the correct amount of flash light required.

Set your camera to Program “P” or a Subject Program Mode (such as Land-

the camera. Please refer to the camera’s operating instructions for the setting

Please observe the hints given for PA and PS program control in sec-

which measures the light reaching the film through the camera lens. The elec-

as soon as the film has been exposed by the correct amount of light, thereby

taken into account. You need not worry about the flash, the camera’s electro-

For the maximim flash range please observe the distance given in the LC dis-

scape, Portrait, Sports, etc.). Select the autofocus mode “Single-AF (S)” on

Use a tripod for the „Night Shots Program“ to avoid the danger of

Some cameras automatically switch the mecablitz to TTL flash mode

Having completed the above settings, problem-free flash photography can

4.1 TTL flash mode (Fig. 3) For the digital cameras Dimage 5, 7 and 7i please refer to the hints

The TTL flash mode is a very simple way to achieve excellent flash shots. In

tors influencing correct exposure of the film (filters, change of aperture and

this mode exposure readings are taken by a sensor built into the camera,

commence as soon as the mecablitz indicates flash readiness (see 5.1).

camera shake in connection with slow shutter speeds!

when in Program “P” or a Subject Program Mode.

4. Operating modes of the mecablitz

Set the „TTL“ mode on the mecablitz (see 4.1).

given in section 4.2 and 4.3.

Settings on the flash unit

Settings on the camera

tion 6.1.

procedure.

  • The setting becomes immediately effective. The LC display returns to normal display after approx. 5 sec.
  • The setting becomes immediately effective. The LC display returns to its normal state after approx. 5 sec.

In Programmed Auto Flash Mode the camera controls the aperture and shut-

vated merely by depressing the „Mode“ or „Zoom“ key or by touching the

The mecablitz should always be turned off by the main switch if it is

  • Continue depressing the key combination „Select“ (= „Mode“ key + „Zoom“ key) until the mecablitz LC display indicates „3m“ (= 3 minutes).
  • Continue depressing the „Zoom“ key until „OFF“ flashes on the mecablitz LC display.
  • Continue depressing the key combination „Select“ (= „Mode“ key + „Zoom“ key) until the mecablitz LC display indicates „3m“ (= 3 minutes).
  • Continue depressing the „Zoom“ key until „ON“ flashes on the mecablitz LC display.

ter speed, as well as the mecablitz, automatically so that optimal results are

After automatic switch-off the last-used settings are retained and instantly

available when the flash unit is switched on again. The flash unit is reacti-

3. Programmed Auto Flash Mode (Full Auto Mode)

always assured in most photographic situations, including fill-in flash.

The Auto-OFF function can be deactivated whenever required:

  • Switching off the camera’s exposure metering system.

not going to be used for an extended period!

shutter release (wake-up function).

Turning off the Auto-OFF function

Turning on the Auto-OFF function

  • Actuating the shutter release

Page 5 of the Metz 44 AF-3M user manual —
Pagina 5 · klik om te vergroten
Pagina 5

light reflection by the subject (average amount of light reflected by flash-shot

between subject and background! The correction value is set on the camera.

groundNegative correction value (approx. 1 to 2 f-stops). Correction

Exposure correction by changing the lens diaphragm is not possible because

underexposed. The shot will then have to be repeated with the next smaller f-num-

ber (e.g. f/8 instead of f/11) or the flash-to-subject distance or reflecting surface

light, or a bright background that reflects a great deal of light, can result in

situation. The actual extent of correction depends on the contrast prevailing

Please refer to the camera’s operating instructions for details concerning set-

value settings can change the maximum flash range indicated on the

After the exposure do not forget to reset the TTL flash exposure cor-

must be reduced (e.g. with bounce flash). Please note the maximum flash range

4.1.2 Manual TTL flash exposure correction The TTL auto flash mode of most cameras is matched to a 25 % degree of

cameras to manually match the TTL flash exposure with the photographic

value (approx. 1 to 2 f-stops). Light subject in front of a dark back-

If „o.k.“ is not displayed after the exposure, then this means that the shot was

subjects). Consequently, a dark background that absorbs a great deal of

A dark subject in front of a bright background: Positive correction

To offset this effect (see Table 1) a correction value can be set on some

mecablitz LC display and match it to the given correction value

the camera’s automatic exposure system will automatically regard the

4.1.3 Correct exposure indication in TTL flash mode (Fig. 4) „o.k.“ correct exposure confirmation only appears on the mecablitz LC

display if the shot was correctly exposed in TTL flash mode!

changed diaphragm as the normal working aperture.

rection back to the normal value on the camera!

indicated on the mecablitz LC display (see 5.4.1).

(depends upon the camera model)!

under or over exposure, respectively.

play of the mecablitz (see 5.4). If flash exposure was correct, the LC display of

selecting the film please check whether limits regarding maximum film

  • The setting becomes immediately effective. The LC display returns to its normal state after approx. 5 sec.

The TTL flash mode is supported by all camera modes (such as Program “P”,

  • Continue depressing the „Mode“ key until „TTL“ flashes on the LC display.

Pronounced differences in contrast, e.g. a dark subject in snow, may make it

camera’s operating instructions) when in Program “P” or a Subject Program

balanced exposure between subject and background with contre-jour shots.

Ensure that the contre-jour light source does not shine directly into the

In this instance there is no setting or display on the mecablitz for TTL fill-in flash.

speed or ISO value (e.g. maximum ISO 1000) are applicable to the

Aperture Priority Mode “A”, Shutter Priority Mode “S”, Subject Program

To test the TTL function a film must be loaded in the camera. When

Various cameras automatically activate TTL flash operation on the

4.1.1 Automatic TTL fill-in flash in daylight (Fig. 5 and 6) Most cameras automatically activate the fill-in flash mode in daylight (see

Fill-in flash overcomes troublesome dense shadows and produces a more

The camera’s computer-controlled metering system sets the most suitable

given camera when in TTL mode (refer to the camera’s operating

mecablitz when in Program “P” or a Subject Program Mode.

combination of shutter speed, working aperture and flash output.

lens as this will mislead the camera’s TTL metering system!

the mecablitz indicates „o.k.“ for about 3 sec. (see 4.1.3).

necessary to correct the exposure settings (see 4.1.2).

Modes, Manual Mode “M”, etc.).

Setting procedure for TTL mode

Mode.

tings! · instructions)!

Page 6 of the Metz 44 AF-3M user manual —
Pagina 6 · klik om te vergroten
Pagina 6

confirmation given on the mecablitz LC display in the manual flash mode!

Select the aperture and shutter speed (with „M“) on the camera according to

  • Continue depressing the „Mode“ key until „MLo“ flashes on the LC display.

when in Program “P” or in one of the Subject Program Modes. Manual

Set „Av“ aperture priority or the „M“ or „X“ manual modes on the camera.

4.4.1 Manual flash mode M with full light output In this mode the mecablitz always fires uncontrolled flashes at full light out-

put. Adaptation to the given photographic situation is only by adjusting the

indicate the flash-to-subject distance that has to be maintained for a correct

  • The setting becomes immediately effective. The LC display is returned to its normal state after approx. 5 sec.

4.4.2 Manual flash mode MLo with partial light output In this mode the flash unit always fires uncontrolled flashes at 1/8th (Low) of

corresponding aperture setting on the camera. The mecablitz LC display will

  • The setting becomes immediately effective. The LC display is returned to its normal state after approx. 5 sec.

4.4 Manual flash mode Various cameras automatically switch the mecablitz to TTL flash mode

flash operation is then no longer possible. There is no correct exposure

the given photographic situation (see the camera’s operating instructions).

aperture setting on the camera accordingly. The mecablitz LC display will

  • Continue depressing the „Mode“ key until „M“ flashes on the LC display.

full light output. Adaptation to the photographic situation is by selecting a

indicate the flash-to-subject distance that must be maintained for correct

Setting procedure for the manual flash mode MLo

Setting procedure for the manual flash mode M

exposure (see also 5.4.2).

exposure (see also 5.4.2).

tering) is a modern variant of TTL flash operation. The cameras do not

When the camera’s shutter release is pressed for picture shooting a preflash

is fired to measure the subject’s reflection. With the aid of its exposure system

electronics captures the light reflected by the subject and determines the opti-

mal weighting for the 4 segments of flash exposure metering on the basis of

The mecablitz must be set to TTL mode. Multi-zone flash exposure metering is

not specifically set or displayed on the mecablitz. For the setting procedure of

multi-zone flash metering on the camera and other details please refer to the

displayed on the mecablitz. Please refer to the camera manual for the setting

Dimage 7 and 7i! Multi-zone flash exposure metering (preflash me-

and the 14-segment honeycomb pattern multi-zone metering, the camera’s

the measured light distribution and the information given by the AF system.

4.3 ADI flash control (Advanced Distance Integration) For system-induced reasons, only possible with Dimage 5, 7 and 7i!

ADI flash control is a modern variant of TTL flash operation. The ca-

4.2 Multi-zone flash exposure metering (preflash metering) For system-induced reasons only possible with Minolta Dimage 5,

meras do not permit standard TTL flash operation without preflash.

ADI flash control is a multi-zone flash metering system (preflash metering)

The mecablitz must be set to TTL mode. ADI flash control is not specifically

The subsequent main flash and the consequent exposure are performed

Also see section 5.3 for the display of exposure symbols in the

permit standard TTL flash operation without preflash.

according to the results obtained by preflash metering.

procedure of ADI flash control and other details.

expanded by additional guide number control.

camera’s viewfinder.

camera manual.

Page 7 of the Metz 44 AF-3M user manual —
Pagina 7 · klik om te vergroten
Pagina 7

for parallax error. For this purpose depress the unlocking button of the reflec-

For close-ups it is necessary to ensure that certain minimum lighting distances

between 1/30th sec. and 1/125th sec. (see the camera’s operating instructions). No

mode) triggering the mecablitz by the end of the exposure time. Second-cur-

speeds (slower than 1/30 s) or when shooting moving objects that have their

instead of building up in front of it, as is the case when the flash is synchron-

4.5.2 Close-ups / Macrophotography The flash reflector can be swivelled down by an angle of -7° to compensate

The minimum lighting distance is approx. 10 per cent of the maximum flash

4.6.1 Normal synchronisation (Fig. 7) In normal synchronisation the mecablitz is triggered at the beginning of the shutter

time (1st curtain synchronisation). Normal synchronisation is the standard mode on

all cameras, and is suitable for most flash shots. Depending upon the given mode,

the camera is changed over to the camera’s sync speed, the customary ones being

The REAR function is set on the camera (see operating instructions of

indicated on the LC display when the reflector is swivelled down, then be

guided by the maximum flash range indicated by the mecablitz when the

settings have to be made on the mecablitz, nor is there any display for this mode.

tain synchronisation is particularly advantageous when using slow shutter

own source of light. Second-curtain synchronisation gives a more realistic

impression of movement because the light streaks behind the light source

range indicated on the LC display. Since the maximum flash range is not

4.6.2 REAR - Second-curtain synchronisation (Fig. 8) Some cameras offer the facility of second-curtain synchronisation (REAR

ised with the 1st shutter curtain! Depending on its operating mode, the

the camera). It is not displayed on the mecablitz.

camera uses shutter speeds slower than its sync speed.

are maintained to avoid overexposure.

tor and swivel down the reflector.

reflector is in its normal position!

4.6 Flash synchronisation

4.5.1 Bounce flash Photos shot with full frontal flash are easily recognized by their harsh, dense

both the subject and the background. For this situation the reflector is turned

The reflector can be turned verticall up to 90°. The reflector head is mechani-

cally interlocked in its basic position. Press the pushbutton to unlock and turn

by a sufficiently wide angle so that direct light can no longer fall on the sub-

The light bounced off the reflecting surfaces produces a soft and uniform illu-

tral colour, and it must not be structured (e.g. wooden beams in a ceiling) as

these might cause shadows. For colour effects just select the reflective surface

Take into account that the maximum flash range is considerably dimi-

nished when bouncing the flash. The following rule of thumb will help

you determine the maximum flash range for a room of normal height:

ground to the background. This phenomenon can be avoided with bounce

flash because the diffused light will produce a soft and uniform rendition of

When turning the reflector vertically, it is essential to ensure that it is moved

ject. Consequently, always turn the reflector at least to the 60° lock-in posi-

mination of the subject. The reflecting surface must be white or have a neu-

shadows. This is often associated with a sharp drop in light from the fore-

in such a manner that the flash is bounced off a suitable reflective surface

tion. The distance readings on the LC display will disappear. The flash-to-

subject distance via the ceiling or wall is an unknown magnitude.

guide number Maximum flash range = flash-to-subject distance x 2

(e.g. ceiling or wall of the room).

4.5 Flash techniques

in the desired colour.

the reflector head.

Page 8 of the Metz 44 AF-3M user manual —
Pagina 8 · klik om te vergroten
Pagina 8

Dimage 5, 7 and 7i. These cameras permit flash shots to be taken at all shut-

5.3.2 Dimage 5, 7, 7i The below symbols are only displayed in the camera’s LCD monitor when the

Shutter speeds slower than the flash sync speed can be set, depending upon

The symbols indicated in your camera’s viewfinder may deviate from

those given in the above table, since some symbols are only possible

on specific cameras. For more details regarding viewfinder informa-

Flash symbol lights constantly or flashes slowly: The mecablitz is

the given camera model and the selected flash synchronisation (see also

ter speeds. Shutter speeds faster than 1/125 sec. should not be used for

system. They are not displayed in playback mode (e.g. right after picture

There is no automatic flash sync speed control with the digital cameras

shooting situations where full light output of the mecablitz is required.

A flash is fired when the camera’s shutter release is pressed.

shutter release is lightly touched for activation of the camera’s metering

tion please refer to the operating instructions of your camera.

The existing shooting situation requires the use of flash.

5.3 Displays in the camera’s viewfinder or LCD monitor

Symbol flashes rapidly after shooting:

The picture was correctly exposed.

Correct exposure confirmation:

5.3.1 Dynax / Maxxum Symbols in viewfinder: Meaning:

Flash readiness indication:

ready for firing.

Symbol flashes:

4.6.2 and 4.6.3).

shooting).

setting will give added prominence to the background at lower ambient light

Accordingly, shutter speeds that are slower than the camera’s sync speed are

automatically adjusted by the camera. Some cameras automatically activate

5.1 Flash readiness indication The flash readiness symbol lights up on the mecablitz when the flash capa-

citor is charged, thereby indicating that flashes can be fired for the next shot.

Flash readiness is also transmitted to the camera for corresponding display in

incorrect if the camera has changed over to flash sync speed in the meantime

Shutter speeds faster than the camera sync speed cannot be adjusted or they

Various cameras have a sync speed range, e.g. 1/30th sec. to 1/125th

sec. (see the camera’s operating instructions). The actual sync speed set

„Av“ aperture priority, night shots program, etc.). No settings are made on

If a picture is shot before flash readiness is signalled in the camera’s view-

finder, then the flash unit will not be triggered so that the exposure may be

5.2 Automatic flash sync speed control Depending upon the camera model and camera mode, the shutter speed is

changed to flash sync speed when flash readiness is reached (see camera’s

by the camera depends upon the camera mode, the ambient light and

4.6.3 Slow synchronisation / SLOW Various cameras feature slow flash synchronisation in certain modes. This

levels. This is achieved by matching the shutter speed to the ambient light.

SLOW synchronisation in connection with certain camera programs (e.g.

Use a tripod to avoid camera shake with slow shutter speeds!

are automatically changed to the camera’s sync speed.

the mecablitz nor is there any display for this mode.

5. mecablitz and camera functions

the focal length of the lens used.

the viewfinder (see 5.3).

operating instructions).

(see 5.2).

Page 9 of the Metz 44 AF-3M user manual —
Pagina 9 · klik om te vergroten
Pagina 9

avoid overexposure, the minimum flash-to-subject distance should not be less

either in meter (m) or feet (ft). To change between the two, proceed in the fol-

  • Keep the „Select“ key combination depressed (= „Mode“ key + „Zoom“ key).

than 10 % of the indicated value. Adaptation to the given photographic si-

5.4.2 Maximum flash range indication in the manual flash modes M and MLo

The mecablitz LC display indicates the distance to be maintained for correct

5.4.4 Blanking out the maximum flash range display The mecablitz LC display does not indicate any distances when the reflector

exposure of the subject. Adaptation to the given photographic situation is

achieved by changing the aperture setting on the lens and selecting either

In this example the maximum flash range extends from 0.6 m to 6.2 m.

Ideally, the subject should be located within a distance range of approx.

This example shows that the principal subject should be at a distance of

ISO 6400) and large aperture openings. An arrow or triangle after the

5.4.5 Meter-Feet changeover (m - ft) The maximum flash range indicated by the mecablitz LC display can be

5.4.3 Exceeding the display range The mecablitz can indicate a maximum range of 199 m or 199 ft. This

display range can be exceeded in the event of high ISO values (e.g.

„M“ for full light output or „MLo“ for partial light output (see 4.2).

distance value indicates that the display range has been exceeded.

tuation is possible by changing the aperture setting on the lens.

head is swivelled up or down out of its normal position!

  • Turn off the mecablitz by its main switch.

6.2 m from the mecablitz.

2.5 m and 4.3 m.

lowing manner:

Example:

Example:

number and the transmitted values. Flash mode, maximum flash range, aper-

(blue) The shot was correctly exposed. This symbol may only briefly be

ture and zoom reflector position are all indicated in the mecablitz LC display.

If the mecablitz operates without having received data from the camera (e.g.

reflector position and „M.Zoom“ are indicated. Aperture and maximum flash

Always observe the maximum flash range indicated by the mecablitz LC dis-

exposure correction to the mecablitz which automatically adapts its settings

accordingly. It calculates the maximum flash range on the basis of its guide

range are only displayed if the camera transmits the corresponding data to

Some cameras suppress the maximum flash range indication on the

mecablitz LC display in the event of high ISO values (e.g. ISO 6400)

or flash exposure corrections.The aperture is not indicated in the LC

5.4.1 Maximum flash range indication in TTL flash mode The mecablitz LC display indicates the maximum flash range. The indicated

play. The subject should be within approx. 40 % and 70% of the indicated

value. This gives the electronic circuit sufficient scope for compensation. To

5.4 Information in the LC display The cameras transmit the ISO sensitivity, the focal length (mm), f-stop and

applies to most photographic situations. Pronounced deviations from this

reflection factor, e.g. highly reflective or poorly reflecting objects, can in-

Please also refer to the hints given in the operating instructions of your

when the camera is switched off), then only the selected flash mode, the

display of the mecablitz when the digital cameras Dimage 5 and

value relates to a factor of 25 % of light reflection by the subject, which

(red) The mecablitz is switched on but not yet ready for firing.

(white) The mecablitz is switched on and ready for firing.

fluence the maximum flash range of the mecablitz.

indicated after shooting.

Dimage7, 7i are used.

the mecablitz.

camera.

Page 10 of the Metz 44 AF-3M user manual —
Pagina 10 · klik om te vergroten
Pagina 10

reflector does not have a 24 mm position. Manual focal length setting

If manual adjustment of the zoom reflector results in a setting in which

then the reflector position indicated on the mecablitz display will start

  • A reflector position of 70 mm has been manually adjusted on the mecablitz („M.Zoom“ is displayed).
  • „70 mm“ for zoom position will start to flash on the mecablitz LC display because the shot will not be fully illuminated right out to the image corners.

(comparable to the extended zoom mode described in section 5.6.3).

In the wide-angle setting of the zoom lens, this will cause the 28 mm

indication to flash in the LC display of the mecablitz because its zoom

The mecablitz LC display indicates „M.Zoom“ for manual zoom setting and

the current zoom position (mm). The setting becomes instantly effective. The

stance to achieve specific lighting effects (e.g. hot-spot, etc.). Repeated de-

pression of the „Zoom“ key on the mecablitz will successively select the fol-

the shot will not be fully illuminated right out to the image corners,

5.6.2 Manual zoom mode „M.Zoom“ The position of the zoom reflector can also be manually changed, for in-

  • Continue pressing the „Zoom“ key on the mecablitz until „Auto Zoom“ appears on the display. The setting becomes instantly effective. The LC

display is switched back to its normal state after approx. 5 sec.

display is switched back to its normal state after approx. 5 sec.

28 mm - 35 mm - 50 mm - 70 mm - 85 mm - 105 mm

There are various ways to return to „Auto Zoom“:

  • You are using a lens focal length of 50 mm.

on the reflector is not necessary.

to flash as a warning.

lowing reflector positions:

Example:

the mecablitz LC display illumination. The LC display illumination is switched

5.6 Motor zoom reflector The reflector of the mecablitz provides full light coverage for lenses of 28 mm

to the flash unit, then the zoom reflector position will be automatically adapted

to the focal length of the lens. When the mecablitz is turned on, the LC display

length. If a focal length shorter than 28 mm is used, then the „28“ indicated

on the LC display will start to flash as an indication that the mecablitz cannot

camera positions the reflector so that the flash coverage is larger than

necessary in order to guarantee a complete illumination of the picture

5.5 LC display illumination Keep the „Mode“ or „Zoom“ key depressed for approx. 10 sec. to activate

The settings on the mecablitz are not changed when the above keys

If the shot was correctly exposed in TTL flash mode, then the LC display illu-

5.6.1 „Auto-Zoom“ If the mecablitz is operated with a camera that transmits the focal length data

A wide-angle diffuser (optional extra, see section 7) can be used for

cameras Dimage 5, 7, or 7i, the focal length position of the reflector

can deviate from the focal length set on the lens. This is because the

reflector of the mecablitz is automatically controlled by the digital

  • Release the „Select“ key combination (= „Mode“ key + „Zoom“ key).

lenses as of 20 mm focal length. In cases where the motor zoom

Automatic reflector adaptation commences with lenses of 28 mm focal

  • The flash range indication changes from m to ft or from ft to m.

mination will be activated during „o.k.“ display (see 4.1.3).

will indicate „Auto Zoom“ and the current reflector position.

fully illuminate the shot right out to the image corners.

focal length and longer (35 mm format).

are pressed for the first time!

off when a flash is triggered.

Returning to „Auto-Zoom“

Page 11 of the Metz 44 AF-3M user manual —
Pagina 11 · klik om te vergroten
Pagina 11

  • Continue depressing the „Zoom“ key until „OFF“ flashes on the LC display.

metering area on cameras that feature several AF sensors (please refer to the

mecablitz will not be activated. In such instances some cameras will use their

  • The setting becomes instantly effective. The LC display is switched back to its normal state after approx. 5 sec.

After storage in the memory, the „Ex“ symbol for extended zoom mode will

beam projects a striped pattern on to the subject, and the camera uses this

pattern to focus automatically. The AF beam has a range of approx. 6 m to

If a decentral AF sensor is manually selected by the photographer, or auto-

matically by the camera, then the emitter of the AF measuring beam on the

ambient lighting conditions are insufficient for automatic focusing. The AF

9 m (with a 50 mm/f/1.7 standard lens). Parallax error between lens and AF red light emitter limits the close-up range of the AF measuring beam to

beam can be activated by the camera. The AF mode „Single AF“ or

„ONE-SHOT AF“ must be set on the camera (see the camera’s ope-

The striped pattern of the AF measuring beam only supports the camera’s

central AF sensor. We therefore recommend to activate only the central AF

5.7 AF measuring beam The AF measuring beam is activated by the camera electronics when the

The camera lens must be switched to AF so that the AF measuring

rating instructions). Zoom lenses with a lower initial aperture can

  • Continue depressing the „Select“ key combination (= „Mode“ key + „Zoom“ key) until „Ex“ appears on the LC display.

significantly reduce the range of the AF measuring beam!

no longer be indicated on the mecablitz LC display.

operating instructions of the given camera).

built-in AF illuminator (see camera manual).

Turning off the extended zoom mode

approx. 0.7 m - 1 m.

on the LC display, thereby warning the user that the required 24 mm reflector

The focal length set on the camera lens is 35 mm. The extended zoom mode

focal length setting of 35 mm and longer. Since the start position of the zoom

reflector is 28 mm, a focal length of less than 35 mm will cause „28“ to flash

Shots with a 28 mm to 35 mm focal length of the lens will be correctly

  • Continue depressing the „Zoom“ key until „ON“ flashes on the LC display.

5.6.3 Extended zoom mode The extended zoom mode (Ex) reduces the focal length setting of the meca-

sets a 28 mm reflector position on the mecablitz even though 35 mm conti-

The extended zoom mode is only possible in the „Auto Zoom“ mode with a

  • The setting becomes instantly effective. The LC display is switched back to its normal state after approx. 5 sec.

After the setting procedure, the „Ex“ symbol for extended zoom mode will

Please note that the wider illumination coverage in extended zoom

blitz by one step compared with the focal length of the camera’s lens! The

resulting wider light coverage inside rooms provides additional stray light

illuminated right out to the image corners by the mecablitz also in

  • Briefly turn off the mecablitz by its main switch. When the flash unit is turned on again the mecablitz display will indicate „Auto Zoom“.
  • Continue depressing the „Select“ key combination (= „Mode“ key + „Zoom“ key) until „Ex“ appears on the LC display.

mode results in a diminished maximum flash range!

continue to be indicated on the mecablitz LC display!

position for extended zoom mode cannot be set.

(reflections) to achieve softer flash illumination.

nues to be indicated on the LC display!

Turning on the extended zoom mode

Example of extended zoom mode:

Or:

extended zoom mode!

Page 12 of the Metz 44 AF-3M user manual —
Pagina 12 · klik om te vergroten
Pagina 12

detail all camera-specific capabilities, settings, displays, etc. For more details

The multitude of camera models and their peculiarities make it impossible to

6.1.2 High-speed synchronisation (HSS) For system-induced reasons, high-speed synchronisation is not supported by

duction. This function only supports the flash unit integrated in the camera. It

concerning the operation of a flash unit please refer to the corresponding

  • The creative program control cannot be activated when the flash unit is switched on.

6.1.3 Cordless REMOTE flash control For system-induced reasons the cordless REMOTE flash control is not sup-

6.1.4 Preflash function for red-eye reduction Various cameras offer the possibility to activate a preflash for red-eye re-

6.1.1 Creative PA and PS program control Various cameras feature a creative PA and PS program control (shiftable

Please refer to the operating instructions of the given camera.

6.1 Special functions that are not supported in flash mode

  • No flash unit can be used in the camera’s P A and P S modes.

6. Special remarks concerning the cameras

chapters in the operating instructions for the given camera!

does not support external flash units, such as the mecablitz.

aperture/shutter program).

ported by the mecablitz.

the mecablitz.

5.8 Triggering control The camera prevents the triggering of a flash if the ambient light level is suffi-

Mode and in the Shutter Priority Mode “S” (see operating instructions for the

camera). The triggering control can be deactivated on some camera models:

played in the camera’s viewfinder when the shutter release is lightly touched.

cient for an exposure in the normal mode. The exposure is then completed

with the shutter speed given in the display or viewfinder of the camera. The

viewfinder is extinguished. In this event no flash is fired when the camera’s

On the Dynax 800si, triggering control is activated by the individual

function “5” (see camera manual). When a Dynax 7 camera is used,

triggering control is activated when the flash-ready signal in the camera’s

On various cameras the triggering control only works in the Program “P”

To do so, press and hold down the flash button on the camera during

The camera selects a suitable shutter speed/aperture combination and a

5.9 Return to basic setting The mecablitz is returned to its basic setting when the „Mode“ key is kept

shooting (see camera manual). The flash-ready signal will again be dis-

triggering control is only possible in the camera’s Full Auto Mode

  • The „Auto-OFF“ (3m ON) function is activated
  • The “Ex” extended zoom mode is cancelled.
  • The automatic zoom mode „Auto-Zoom“

flash is fired when a picture is shot.

depressed for at least three seconds.

The following settings are adjusted:

(green P symbol).

  • The „TTL“ flash mode

shutter is tripped.

Page 13 of the Metz 44 AF-3M user manual — 7. Optional extras
Pagina 13 · klik om te vergroten
Pagina 13

for about 10 seconds by its main switch. Check the camera settings and find

out if the flash unit’s foot is correctly mounted in the camera’s accessory shoe.

The flash capacitor incorporated in the flash unit undergoes a physical change

reason it is necessary to switch on the mecablitz for approx. 10 minutes every

Should the LC display indicate meaningless information or should the flash

unit not work properly in the individual modes, then switch off the flash unit

when the flash unit is not switched on for prolonged periods of time. For this

3 months (see 2.4!). The batteries must supply sufficient power for flash readi- ness to be indicated within 1 minute after the mecablitz was switched on.

The flash unit must operate properly when it is switched on again. Contact

Remove any grime and dust with a soft, dry or silicon-treated cloth. Never

use detergents that could damage plastic parts.

your local dealer should this not be the case.

8. Advice in the event of a fault

9. Maintenance and care

Forming the flash capacitor

Consists of 4 colour filters to achieve special lighting effects, plus a clear fil-

No guarantee is given for malfunctions and damage to the mecablitz

For full illumination in conjunction with lenses of 24 mm and up. The range

A diffuser to achieve soft illumination in the simplest possible manner. The

effect is very impressive because the pictures are given a very soft atmos-

phere. Facial colours are rendered more naturally. However, loss of light

is reduced by the factor 1.4 due to the corresponding loss of light.

caused by the use of accessories from other manufacturers!

The soft directed light diminishes dense shadows.

ter to hold colour foils in any colour.

halves the maximum flash range.

  • 24mm wide-angle diffuse r (Item No. 000044217)

7. Optional extras

  • Colour filter set 44-32 (Item No. 00004432A)
  • Mecabounce 44-90 (Item No. 000044900)
  • Bounce diffuser 54-23 (Item No. 000054236)
Page 14 of the Metz 44 AF-3M user manual —
Pagina 14 · klik om te vergroten
Pagina 14

Errors excepted. Subject to changes!

Swivelling range and locking positions of flash head:

Flash unit with power sourcesapprox. 400 g
Upwards / downwards60°, 75°, 90° / -7°

Flash unit, Operating Instructions

Dimensions approx. in mm:

75 x 125 x 108 (WxHxD)

Weight:

Included:

(at full light output)

(at full light output)

approx. 240 with high-capacity alkaline manganese batteries

approx. 5 s with high-capacity alkaline manganese batteries

In the metric system44; In the imperial system: 144

Maximal guide number at ISO 100/21°, 105 mm zoom:

Approx. 1/200th to 1/20,000th sec. (in TTL mode)

In M mode approx. 1/200th sec. at full light output

approx. 205 with NiMH batteries (1600 mAh)

approx. 85 with NiCad batteries (600 mAh)

In MLo mode approx. 1/5,000th sec.

approx. 370 with lithium batteries

approx. 4 s with NiCad batteries

approx. 4 s with NiMH batteries

approx. 6s with lithium batteries

10. Technical data

Colour temperature:

ISO 6 to ISO 6400

Number of flashes:

Flash durations:

approx. 5600 K

Synchronisation:

Recycling time:

Film speed:

Low-voltage ignition

Page 15 of the Metz 44 AF-3M user manual — Disposal of batteries
Pagina 15 · klik om te vergroten
Pagina 15

- The device they powered switches itself off and indicates "Spent Batteries".

Please return spent batteries to collecting points should they exist in your

To ensure short-circuit safety please cover the battery poles with adhesive

Do not dispose of spent batteries with domestic rubbish.

- They no longer function properly after prolonged use.

Please return only fully discharged batteries.

Normally, batteries are fully discharged if:

Disposal of batteries

tape.

country!

Vraag stellen over de Metz 44 AF-3M

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Metz 44 AF-3M

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Metz 44 AF-3M handleiding-pdf

108 pagina's·1.3 MB·Digitale camera·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…