
flash is fired. The high energy of the flash light will burn the material or
interval of at least 10 minutes after 15 flashes, otherwise the flash unit
damage the reflector screen if this is not observed.
will be overloaded.
However, we recommend that you study these Operating Instructions before-
It is only natural that you should want to use your flash unit straight away.
This flash unit is compatible with analog Minolta “Dynax” and “Maxxum”
cameras and digital “Dimage” cameras (see Table 1). It cannot be used for
We congratulate you on purchasing this flash unit and thank you for your
hand to be able to fully exploit and utilize all the capabilities offered.
Please also open the back cover with the illustrations.
lead to severe visual disorders - even blindness!
cameras made by other manufacturers.
light and cause an accident!
confidence in Metz products.
Foreword

Dynax 9xi Dynax 7xi Dynax 5xi Dynax 3xi / 4 Dynax Spxi Dynax 8000i, Maxxum 8700i Dynax 7000i, Maxxum 7700i Dynax 5000i, Maxxum 5700i Dynax 3000i, Maxxum 3700i Vectis S-1 Dimage 7, 7i Dimage 5
Dynax 7 Dynax 5 Dynax 800si Dynax 700si Dynax 650si Dynax 600si Dynax 505si super, Maxxum XTsi Dynax 505si, Maxxum HTsi Dynax 500si super, Maxxum 500si Dynax 500si, Maxxum 400si Dynax 404si Dynax 303si
Correct exposure confirmation in camera viewfinder
Multi-zone flash metering (preflash metering)
Flash-ready indication in camera viewfinder
Automatic motor zoom reflector control
Manual TTL flash exposure correction
Automatic flash sync speed control
Maximum flash range indication
Programmed auto flash mode
AF measuring beam control
TTL fill-in flash control

2.2.2 Replacing batteries (Fig. 1) The batteries are exhausted if the recycling time (elapsing from the triggering
of a full-power flash, e.g. in the M mode, to the moment the flash ready indi-
that the batteries are of the same brand and type and have the same
destroy the flash unit! Replace all batteries at a time and make sure
2.3 Switching the flash unit on and off The flash unit is switched on with the main switch on top of the battery com-
2.4 Auto-OFF for mecablitz (Fig. 2) To save battery power and prevent inadvertent battery discharge, the meca-
blitz is factory-set to automatically switch-over to standby mode (Auto-OFF),
When loading batteries ensure correct polarity, as indicated by the
symbols in the battery compartment. Mixed up battery poles may
Exhausted batteries must not be thrown in the dustbin! Help protect
To turn off the flash unit push the main switch down to its bottom position.
If your mecablitz is not going to be used for an extended period of
while flash readiness and the LC display are simultaneously switched off,
the environment and dispose of exhausted batteries at the appro-
time, we recommend to switch it off with the main switch and to
partment cover. In the upper „ON“ position, the mecablitz is on.
cator lights up again) exceeds 60 seconds.
remove the power sources (batteries).
priate collecting points.
approx. 3 minutes after:
Remove the batteries from the mecablitz if it is not going to be used
2.1.1 Mounting the mecablitz on the camera Turn off the camera and the mecablitz by their main switch!
2.1.2 Removing the mecablitz from the camera Turn off the camera and the mecablitz by their main switch!
2.2.1 Suitable batteries The mecablitz can be operated with any of the following batteries:
for an extended period of time.
2.1 Mounting the mecablitz
environment (no cadmium).
2.2 Power supply
capacity!

tronic control circuit within the camera transmits a stop signal to the mecablitz
instantly interrupting the flash. The advantage of this flash mode is that all fac-
focal length with zoom lenses, extensions for close-ups, etc.) are automatically
nic system automatically determines the correct amount of flash light required.
Set your camera to Program “P” or a Subject Program Mode (such as Land-
the camera. Please refer to the camera’s operating instructions for the setting
Please observe the hints given for PA and PS program control in sec-
which measures the light reaching the film through the camera lens. The elec-
as soon as the film has been exposed by the correct amount of light, thereby
taken into account. You need not worry about the flash, the camera’s electro-
For the maximim flash range please observe the distance given in the LC dis-
scape, Portrait, Sports, etc.). Select the autofocus mode “Single-AF (S)” on
Use a tripod for the „Night Shots Program“ to avoid the danger of
Some cameras automatically switch the mecablitz to TTL flash mode
Having completed the above settings, problem-free flash photography can
4.1 TTL flash mode (Fig. 3) For the digital cameras Dimage 5, 7 and 7i please refer to the hints
The TTL flash mode is a very simple way to achieve excellent flash shots. In
tors influencing correct exposure of the film (filters, change of aperture and
this mode exposure readings are taken by a sensor built into the camera,
commence as soon as the mecablitz indicates flash readiness (see 5.1).
camera shake in connection with slow shutter speeds!
when in Program “P” or a Subject Program Mode.
Set the „TTL“ mode on the mecablitz (see 4.1).
given in section 4.2 and 4.3.
Settings on the flash unit
Settings on the camera
tion 6.1.
procedure.
In Programmed Auto Flash Mode the camera controls the aperture and shut-
vated merely by depressing the „Mode“ or „Zoom“ key or by touching the
The mecablitz should always be turned off by the main switch if it is
ter speed, as well as the mecablitz, automatically so that optimal results are
After automatic switch-off the last-used settings are retained and instantly
available when the flash unit is switched on again. The flash unit is reacti-
always assured in most photographic situations, including fill-in flash.
The Auto-OFF function can be deactivated whenever required:
not going to be used for an extended period!
shutter release (wake-up function).
Turning off the Auto-OFF function
Turning on the Auto-OFF function

light reflection by the subject (average amount of light reflected by flash-shot
between subject and background! The correction value is set on the camera.
Exposure correction by changing the lens diaphragm is not possible because
underexposed. The shot will then have to be repeated with the next smaller f-num-
ber (e.g. f/8 instead of f/11) or the flash-to-subject distance or reflecting surface
light, or a bright background that reflects a great deal of light, can result in
situation. The actual extent of correction depends on the contrast prevailing
Please refer to the camera’s operating instructions for details concerning set-
value settings can change the maximum flash range indicated on the
After the exposure do not forget to reset the TTL flash exposure cor-
must be reduced (e.g. with bounce flash). Please note the maximum flash range
4.1.2 Manual TTL flash exposure correction The TTL auto flash mode of most cameras is matched to a 25 % degree of
cameras to manually match the TTL flash exposure with the photographic
value (approx. 1 to 2 f-stops). Light subject in front of a dark back-
If „o.k.“ is not displayed after the exposure, then this means that the shot was
subjects). Consequently, a dark background that absorbs a great deal of
A dark subject in front of a bright background: Positive correction
To offset this effect (see Table 1) a correction value can be set on some
mecablitz LC display and match it to the given correction value
the camera’s automatic exposure system will automatically regard the
4.1.3 Correct exposure indication in TTL flash mode (Fig. 4) „o.k.“ correct exposure confirmation only appears on the mecablitz LC
display if the shot was correctly exposed in TTL flash mode!
changed diaphragm as the normal working aperture.
rection back to the normal value on the camera!
indicated on the mecablitz LC display (see 5.4.1).
(depends upon the camera model)!
under or over exposure, respectively.
play of the mecablitz (see 5.4). If flash exposure was correct, the LC display of
selecting the film please check whether limits regarding maximum film
The TTL flash mode is supported by all camera modes (such as Program “P”,
Pronounced differences in contrast, e.g. a dark subject in snow, may make it
camera’s operating instructions) when in Program “P” or a Subject Program
balanced exposure between subject and background with contre-jour shots.
Ensure that the contre-jour light source does not shine directly into the
In this instance there is no setting or display on the mecablitz for TTL fill-in flash.
speed or ISO value (e.g. maximum ISO 1000) are applicable to the
Aperture Priority Mode “A”, Shutter Priority Mode “S”, Subject Program
To test the TTL function a film must be loaded in the camera. When
Various cameras automatically activate TTL flash operation on the
4.1.1 Automatic TTL fill-in flash in daylight (Fig. 5 and 6) Most cameras automatically activate the fill-in flash mode in daylight (see
Fill-in flash overcomes troublesome dense shadows and produces a more
The camera’s computer-controlled metering system sets the most suitable
given camera when in TTL mode (refer to the camera’s operating
mecablitz when in Program “P” or a Subject Program Mode.
combination of shutter speed, working aperture and flash output.
lens as this will mislead the camera’s TTL metering system!
the mecablitz indicates „o.k.“ for about 3 sec. (see 4.1.3).
necessary to correct the exposure settings (see 4.1.2).
Modes, Manual Mode “M”, etc.).
Setting procedure for TTL mode
Mode.
tings! · instructions)!

confirmation given on the mecablitz LC display in the manual flash mode!
Select the aperture and shutter speed (with „M“) on the camera according to
when in Program “P” or in one of the Subject Program Modes. Manual
Set „Av“ aperture priority or the „M“ or „X“ manual modes on the camera.
4.4.1 Manual flash mode M with full light output In this mode the mecablitz always fires uncontrolled flashes at full light out-
put. Adaptation to the given photographic situation is only by adjusting the
indicate the flash-to-subject distance that has to be maintained for a correct
4.4.2 Manual flash mode MLo with partial light output In this mode the flash unit always fires uncontrolled flashes at 1/8th (Low) of
corresponding aperture setting on the camera. The mecablitz LC display will
4.4 Manual flash mode Various cameras automatically switch the mecablitz to TTL flash mode
flash operation is then no longer possible. There is no correct exposure
the given photographic situation (see the camera’s operating instructions).
aperture setting on the camera accordingly. The mecablitz LC display will
full light output. Adaptation to the photographic situation is by selecting a
indicate the flash-to-subject distance that must be maintained for correct
Setting procedure for the manual flash mode MLo
Setting procedure for the manual flash mode M
exposure (see also 5.4.2).
exposure (see also 5.4.2).
tering) is a modern variant of TTL flash operation. The cameras do not
When the camera’s shutter release is pressed for picture shooting a preflash
is fired to measure the subject’s reflection. With the aid of its exposure system
electronics captures the light reflected by the subject and determines the opti-
mal weighting for the 4 segments of flash exposure metering on the basis of
The mecablitz must be set to TTL mode. Multi-zone flash exposure metering is
not specifically set or displayed on the mecablitz. For the setting procedure of
multi-zone flash metering on the camera and other details please refer to the
displayed on the mecablitz. Please refer to the camera manual for the setting
Dimage 7 and 7i! Multi-zone flash exposure metering (preflash me-
and the 14-segment honeycomb pattern multi-zone metering, the camera’s
the measured light distribution and the information given by the AF system.
4.3 ADI flash control (Advanced Distance Integration) For system-induced reasons, only possible with Dimage 5, 7 and 7i!
ADI flash control is a modern variant of TTL flash operation. The ca-
4.2 Multi-zone flash exposure metering (preflash metering) For system-induced reasons only possible with Minolta Dimage 5,
meras do not permit standard TTL flash operation without preflash.
ADI flash control is a multi-zone flash metering system (preflash metering)
The mecablitz must be set to TTL mode. ADI flash control is not specifically
The subsequent main flash and the consequent exposure are performed
Also see section 5.3 for the display of exposure symbols in the
permit standard TTL flash operation without preflash.
according to the results obtained by preflash metering.
procedure of ADI flash control and other details.
expanded by additional guide number control.
camera’s viewfinder.
camera manual.

for parallax error. For this purpose depress the unlocking button of the reflec-
For close-ups it is necessary to ensure that certain minimum lighting distances
between 1/30th sec. and 1/125th sec. (see the camera’s operating instructions). No
mode) triggering the mecablitz by the end of the exposure time. Second-cur-
speeds (slower than 1/30 s) or when shooting moving objects that have their
instead of building up in front of it, as is the case when the flash is synchron-
4.5.2 Close-ups / Macrophotography The flash reflector can be swivelled down by an angle of -7° to compensate
The minimum lighting distance is approx. 10 per cent of the maximum flash
4.6.1 Normal synchronisation (Fig. 7) In normal synchronisation the mecablitz is triggered at the beginning of the shutter
time (1st curtain synchronisation). Normal synchronisation is the standard mode on
all cameras, and is suitable for most flash shots. Depending upon the given mode,
the camera is changed over to the camera’s sync speed, the customary ones being
The REAR function is set on the camera (see operating instructions of
indicated on the LC display when the reflector is swivelled down, then be
guided by the maximum flash range indicated by the mecablitz when the
settings have to be made on the mecablitz, nor is there any display for this mode.
tain synchronisation is particularly advantageous when using slow shutter
own source of light. Second-curtain synchronisation gives a more realistic
impression of movement because the light streaks behind the light source
range indicated on the LC display. Since the maximum flash range is not
4.6.2 REAR - Second-curtain synchronisation (Fig. 8) Some cameras offer the facility of second-curtain synchronisation (REAR
ised with the 1st shutter curtain! Depending on its operating mode, the
the camera). It is not displayed on the mecablitz.
camera uses shutter speeds slower than its sync speed.
are maintained to avoid overexposure.
tor and swivel down the reflector.
reflector is in its normal position!
4.6 Flash synchronisation
4.5.1 Bounce flash Photos shot with full frontal flash are easily recognized by their harsh, dense
both the subject and the background. For this situation the reflector is turned
The reflector can be turned verticall up to 90°. The reflector head is mechani-
cally interlocked in its basic position. Press the pushbutton to unlock and turn
by a sufficiently wide angle so that direct light can no longer fall on the sub-
The light bounced off the reflecting surfaces produces a soft and uniform illu-
tral colour, and it must not be structured (e.g. wooden beams in a ceiling) as
these might cause shadows. For colour effects just select the reflective surface
Take into account that the maximum flash range is considerably dimi-
nished when bouncing the flash. The following rule of thumb will help
you determine the maximum flash range for a room of normal height:
ground to the background. This phenomenon can be avoided with bounce
flash because the diffused light will produce a soft and uniform rendition of
When turning the reflector vertically, it is essential to ensure that it is moved
ject. Consequently, always turn the reflector at least to the 60° lock-in posi-
mination of the subject. The reflecting surface must be white or have a neu-
shadows. This is often associated with a sharp drop in light from the fore-
in such a manner that the flash is bounced off a suitable reflective surface
tion. The distance readings on the LC display will disappear. The flash-to-
subject distance via the ceiling or wall is an unknown magnitude.
guide number Maximum flash range = flash-to-subject distance x 2
(e.g. ceiling or wall of the room).
4.5 Flash techniques
in the desired colour.
the reflector head.

Dimage 5, 7 and 7i. These cameras permit flash shots to be taken at all shut-
5.3.2 Dimage 5, 7, 7i The below symbols are only displayed in the camera’s LCD monitor when the
Shutter speeds slower than the flash sync speed can be set, depending upon
The symbols indicated in your camera’s viewfinder may deviate from
those given in the above table, since some symbols are only possible
on specific cameras. For more details regarding viewfinder informa-
Flash symbol lights constantly or flashes slowly: The mecablitz is
the given camera model and the selected flash synchronisation (see also
ter speeds. Shutter speeds faster than 1/125 sec. should not be used for
system. They are not displayed in playback mode (e.g. right after picture
There is no automatic flash sync speed control with the digital cameras
shooting situations where full light output of the mecablitz is required.
A flash is fired when the camera’s shutter release is pressed.
shutter release is lightly touched for activation of the camera’s metering
tion please refer to the operating instructions of your camera.
The existing shooting situation requires the use of flash.
5.3 Displays in the camera’s viewfinder or LCD monitor
Symbol flashes rapidly after shooting:
The picture was correctly exposed.
Correct exposure confirmation:
5.3.1 Dynax / Maxxum Symbols in viewfinder: Meaning:
Flash readiness indication:
ready for firing.
Symbol flashes:
4.6.2 and 4.6.3).
shooting).
setting will give added prominence to the background at lower ambient light
Accordingly, shutter speeds that are slower than the camera’s sync speed are
automatically adjusted by the camera. Some cameras automatically activate
5.1 Flash readiness indication The flash readiness symbol lights up on the mecablitz when the flash capa-
citor is charged, thereby indicating that flashes can be fired for the next shot.
Flash readiness is also transmitted to the camera for corresponding display in
incorrect if the camera has changed over to flash sync speed in the meantime
Shutter speeds faster than the camera sync speed cannot be adjusted or they
Various cameras have a sync speed range, e.g. 1/30th sec. to 1/125th
sec. (see the camera’s operating instructions). The actual sync speed set
„Av“ aperture priority, night shots program, etc.). No settings are made on
If a picture is shot before flash readiness is signalled in the camera’s view-
finder, then the flash unit will not be triggered so that the exposure may be
5.2 Automatic flash sync speed control Depending upon the camera model and camera mode, the shutter speed is
changed to flash sync speed when flash readiness is reached (see camera’s
by the camera depends upon the camera mode, the ambient light and
4.6.3 Slow synchronisation / SLOW Various cameras feature slow flash synchronisation in certain modes. This
levels. This is achieved by matching the shutter speed to the ambient light.
SLOW synchronisation in connection with certain camera programs (e.g.
Use a tripod to avoid camera shake with slow shutter speeds!
are automatically changed to the camera’s sync speed.
the mecablitz nor is there any display for this mode.
the focal length of the lens used.
the viewfinder (see 5.3).
operating instructions).
(see 5.2).

avoid overexposure, the minimum flash-to-subject distance should not be less
either in meter (m) or feet (ft). To change between the two, proceed in the fol-
than 10 % of the indicated value. Adaptation to the given photographic si-
5.4.2 Maximum flash range indication in the manual flash modes M and MLo
The mecablitz LC display indicates the distance to be maintained for correct
5.4.4 Blanking out the maximum flash range display The mecablitz LC display does not indicate any distances when the reflector
exposure of the subject. Adaptation to the given photographic situation is
achieved by changing the aperture setting on the lens and selecting either
In this example the maximum flash range extends from 0.6 m to 6.2 m.
Ideally, the subject should be located within a distance range of approx.
This example shows that the principal subject should be at a distance of
ISO 6400) and large aperture openings. An arrow or triangle after the
5.4.5 Meter-Feet changeover (m - ft) The maximum flash range indicated by the mecablitz LC display can be
5.4.3 Exceeding the display range The mecablitz can indicate a maximum range of 199 m or 199 ft. This
display range can be exceeded in the event of high ISO values (e.g.
„M“ for full light output or „MLo“ for partial light output (see 4.2).
distance value indicates that the display range has been exceeded.
tuation is possible by changing the aperture setting on the lens.
head is swivelled up or down out of its normal position!
6.2 m from the mecablitz.
2.5 m and 4.3 m.
lowing manner:
Example:
Example:
number and the transmitted values. Flash mode, maximum flash range, aper-
(blue) The shot was correctly exposed. This symbol may only briefly be
ture and zoom reflector position are all indicated in the mecablitz LC display.
If the mecablitz operates without having received data from the camera (e.g.
reflector position and „M.Zoom“ are indicated. Aperture and maximum flash
Always observe the maximum flash range indicated by the mecablitz LC dis-
exposure correction to the mecablitz which automatically adapts its settings
accordingly. It calculates the maximum flash range on the basis of its guide
range are only displayed if the camera transmits the corresponding data to
Some cameras suppress the maximum flash range indication on the
mecablitz LC display in the event of high ISO values (e.g. ISO 6400)
or flash exposure corrections.The aperture is not indicated in the LC
5.4.1 Maximum flash range indication in TTL flash mode The mecablitz LC display indicates the maximum flash range. The indicated
play. The subject should be within approx. 40 % and 70% of the indicated
value. This gives the electronic circuit sufficient scope for compensation. To
5.4 Information in the LC display The cameras transmit the ISO sensitivity, the focal length (mm), f-stop and
applies to most photographic situations. Pronounced deviations from this
reflection factor, e.g. highly reflective or poorly reflecting objects, can in-
Please also refer to the hints given in the operating instructions of your
when the camera is switched off), then only the selected flash mode, the
display of the mecablitz when the digital cameras Dimage 5 and
value relates to a factor of 25 % of light reflection by the subject, which
(red) The mecablitz is switched on but not yet ready for firing.
(white) The mecablitz is switched on and ready for firing.
fluence the maximum flash range of the mecablitz.
indicated after shooting.
Dimage7, 7i are used.
the mecablitz.
camera.

reflector does not have a 24 mm position. Manual focal length setting
If manual adjustment of the zoom reflector results in a setting in which
then the reflector position indicated on the mecablitz display will start
(comparable to the extended zoom mode described in section 5.6.3).
In the wide-angle setting of the zoom lens, this will cause the 28 mm
indication to flash in the LC display of the mecablitz because its zoom
The mecablitz LC display indicates „M.Zoom“ for manual zoom setting and
the current zoom position (mm). The setting becomes instantly effective. The
stance to achieve specific lighting effects (e.g. hot-spot, etc.). Repeated de-
pression of the „Zoom“ key on the mecablitz will successively select the fol-
the shot will not be fully illuminated right out to the image corners,
5.6.2 Manual zoom mode „M.Zoom“ The position of the zoom reflector can also be manually changed, for in-
display is switched back to its normal state after approx. 5 sec.
display is switched back to its normal state after approx. 5 sec.
28 mm - 35 mm - 50 mm - 70 mm - 85 mm - 105 mm
There are various ways to return to „Auto Zoom“:
on the reflector is not necessary.
to flash as a warning.
lowing reflector positions:
Example:
the mecablitz LC display illumination. The LC display illumination is switched
5.6 Motor zoom reflector The reflector of the mecablitz provides full light coverage for lenses of 28 mm
to the flash unit, then the zoom reflector position will be automatically adapted
to the focal length of the lens. When the mecablitz is turned on, the LC display
length. If a focal length shorter than 28 mm is used, then the „28“ indicated
on the LC display will start to flash as an indication that the mecablitz cannot
camera positions the reflector so that the flash coverage is larger than
necessary in order to guarantee a complete illumination of the picture
5.5 LC display illumination Keep the „Mode“ or „Zoom“ key depressed for approx. 10 sec. to activate
The settings on the mecablitz are not changed when the above keys
If the shot was correctly exposed in TTL flash mode, then the LC display illu-
5.6.1 „Auto-Zoom“ If the mecablitz is operated with a camera that transmits the focal length data
A wide-angle diffuser (optional extra, see section 7) can be used for
cameras Dimage 5, 7, or 7i, the focal length position of the reflector
can deviate from the focal length set on the lens. This is because the
reflector of the mecablitz is automatically controlled by the digital
lenses as of 20 mm focal length. In cases where the motor zoom
Automatic reflector adaptation commences with lenses of 28 mm focal
mination will be activated during „o.k.“ display (see 4.1.3).
will indicate „Auto Zoom“ and the current reflector position.
fully illuminate the shot right out to the image corners.
focal length and longer (35 mm format).
are pressed for the first time!
off when a flash is triggered.
Returning to „Auto-Zoom“

metering area on cameras that feature several AF sensors (please refer to the
mecablitz will not be activated. In such instances some cameras will use their
After storage in the memory, the „Ex“ symbol for extended zoom mode will
beam projects a striped pattern on to the subject, and the camera uses this
pattern to focus automatically. The AF beam has a range of approx. 6 m to
If a decentral AF sensor is manually selected by the photographer, or auto-
matically by the camera, then the emitter of the AF measuring beam on the
ambient lighting conditions are insufficient for automatic focusing. The AF
9 m (with a 50 mm/f/1.7 standard lens). Parallax error between lens and AF red light emitter limits the close-up range of the AF measuring beam to
beam can be activated by the camera. The AF mode „Single AF“ or
„ONE-SHOT AF“ must be set on the camera (see the camera’s ope-
The striped pattern of the AF measuring beam only supports the camera’s
central AF sensor. We therefore recommend to activate only the central AF
5.7 AF measuring beam The AF measuring beam is activated by the camera electronics when the
The camera lens must be switched to AF so that the AF measuring
rating instructions). Zoom lenses with a lower initial aperture can
significantly reduce the range of the AF measuring beam!
no longer be indicated on the mecablitz LC display.
operating instructions of the given camera).
built-in AF illuminator (see camera manual).
Turning off the extended zoom mode
approx. 0.7 m - 1 m.
on the LC display, thereby warning the user that the required 24 mm reflector
The focal length set on the camera lens is 35 mm. The extended zoom mode
focal length setting of 35 mm and longer. Since the start position of the zoom
reflector is 28 mm, a focal length of less than 35 mm will cause „28“ to flash
Shots with a 28 mm to 35 mm focal length of the lens will be correctly
5.6.3 Extended zoom mode The extended zoom mode (Ex) reduces the focal length setting of the meca-
sets a 28 mm reflector position on the mecablitz even though 35 mm conti-
The extended zoom mode is only possible in the „Auto Zoom“ mode with a
After the setting procedure, the „Ex“ symbol for extended zoom mode will
Please note that the wider illumination coverage in extended zoom
blitz by one step compared with the focal length of the camera’s lens! The
resulting wider light coverage inside rooms provides additional stray light
illuminated right out to the image corners by the mecablitz also in
mode results in a diminished maximum flash range!
continue to be indicated on the mecablitz LC display!
position for extended zoom mode cannot be set.
(reflections) to achieve softer flash illumination.
nues to be indicated on the LC display!
Turning on the extended zoom mode
Example of extended zoom mode:
Or:
extended zoom mode!

detail all camera-specific capabilities, settings, displays, etc. For more details
The multitude of camera models and their peculiarities make it impossible to
6.1.2 High-speed synchronisation (HSS) For system-induced reasons, high-speed synchronisation is not supported by
duction. This function only supports the flash unit integrated in the camera. It
concerning the operation of a flash unit please refer to the corresponding
6.1.3 Cordless REMOTE flash control For system-induced reasons the cordless REMOTE flash control is not sup-
6.1.4 Preflash function for red-eye reduction Various cameras offer the possibility to activate a preflash for red-eye re-
6.1.1 Creative PA and PS program control Various cameras feature a creative PA and PS program control (shiftable
Please refer to the operating instructions of the given camera.
6.1 Special functions that are not supported in flash mode
chapters in the operating instructions for the given camera!
does not support external flash units, such as the mecablitz.
aperture/shutter program).
ported by the mecablitz.
the mecablitz.
5.8 Triggering control The camera prevents the triggering of a flash if the ambient light level is suffi-
Mode and in the Shutter Priority Mode “S” (see operating instructions for the
camera). The triggering control can be deactivated on some camera models:
played in the camera’s viewfinder when the shutter release is lightly touched.
cient for an exposure in the normal mode. The exposure is then completed
with the shutter speed given in the display or viewfinder of the camera. The
viewfinder is extinguished. In this event no flash is fired when the camera’s
On the Dynax 800si, triggering control is activated by the individual
function “5” (see camera manual). When a Dynax 7 camera is used,
triggering control is activated when the flash-ready signal in the camera’s
On various cameras the triggering control only works in the Program “P”
To do so, press and hold down the flash button on the camera during
The camera selects a suitable shutter speed/aperture combination and a
5.9 Return to basic setting The mecablitz is returned to its basic setting when the „Mode“ key is kept
shooting (see camera manual). The flash-ready signal will again be dis-
triggering control is only possible in the camera’s Full Auto Mode
flash is fired when a picture is shot.
depressed for at least three seconds.
The following settings are adjusted:
(green P symbol).
shutter is tripped.

for about 10 seconds by its main switch. Check the camera settings and find
out if the flash unit’s foot is correctly mounted in the camera’s accessory shoe.
The flash capacitor incorporated in the flash unit undergoes a physical change
reason it is necessary to switch on the mecablitz for approx. 10 minutes every
Should the LC display indicate meaningless information or should the flash
unit not work properly in the individual modes, then switch off the flash unit
when the flash unit is not switched on for prolonged periods of time. For this
3 months (see 2.4!). The batteries must supply sufficient power for flash readi- ness to be indicated within 1 minute after the mecablitz was switched on.
The flash unit must operate properly when it is switched on again. Contact
Remove any grime and dust with a soft, dry or silicon-treated cloth. Never
use detergents that could damage plastic parts.
your local dealer should this not be the case.
9. Maintenance and care
Forming the flash capacitor
Consists of 4 colour filters to achieve special lighting effects, plus a clear fil-
No guarantee is given for malfunctions and damage to the mecablitz
For full illumination in conjunction with lenses of 24 mm and up. The range
A diffuser to achieve soft illumination in the simplest possible manner. The
effect is very impressive because the pictures are given a very soft atmos-
phere. Facial colours are rendered more naturally. However, loss of light
is reduced by the factor 1.4 due to the corresponding loss of light.
caused by the use of accessories from other manufacturers!
The soft directed light diminishes dense shadows.
ter to hold colour foils in any colour.
halves the maximum flash range.

Errors excepted. Subject to changes!
Swivelling range and locking positions of flash head:
Flash unit, Operating Instructions
Dimensions approx. in mm:
75 x 125 x 108 (WxHxD)
Weight:
Included:
(at full light output)
(at full light output)
approx. 240 with high-capacity alkaline manganese batteries
approx. 5 s with high-capacity alkaline manganese batteries
Maximal guide number at ISO 100/21°, 105 mm zoom:
Approx. 1/200th to 1/20,000th sec. (in TTL mode)
In M mode approx. 1/200th sec. at full light output
approx. 205 with NiMH batteries (1600 mAh)
approx. 85 with NiCad batteries (600 mAh)
In MLo mode approx. 1/5,000th sec.
approx. 370 with lithium batteries
approx. 4 s with NiCad batteries
approx. 4 s with NiMH batteries
approx. 6s with lithium batteries
Colour temperature:
ISO 6 to ISO 6400
Number of flashes:
Flash durations:
approx. 5600 K
Synchronisation:
Recycling time:
Film speed:
Low-voltage ignition

- The device they powered switches itself off and indicates "Spent Batteries".
Please return spent batteries to collecting points should they exist in your
To ensure short-circuit safety please cover the battery poles with adhesive
Do not dispose of spent batteries with domestic rubbish.
- They no longer function properly after prolonged use.
Please return only fully discharged batteries.
Normally, batteries are fully discharged if:
tape.
country!
Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.
Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.