charger! Never insert an adapter into an outlet socket on its own !
teries and may result in fire or explosions !
the battery charger or the battery pack !
batteries with this charger !
cause burning or bleaching of the material or may damage the reflector.
concerned and result in an accident.
lead to blindness.
ventilated !

ries to a suitable collection centre !
other manufacturers ! · car !

TTL flash mode (Standard-TTL) Preflash measuring beam with TTL control (e.g. for Olympus and Sony) Red-eye reduction preflash Manual TTL flash exposure correction Canon E-TTL flash mode Canon FE flash exposure lock Nikon matrix-controlled fill-in flash Nikon 3D multi-sensor fill-in flash Nikon D-TTL / D-TTL-3D flash mode Nikon i-TTL / i-TTL-BL flash mode Nikon flash exposure lock Minolta TTL preflash mode / ADI Automatic flash mode Manual flash mode with partial light output settings Slave mode with simultaneous optical triggering with SCA 3083 digital Slave mode with preflash suppressions with SCA 3083 digital Slave mode in cordless Metz Remote System with SCA 3083 digital Manual / automatic aperture setting Manual / automatic ISO setting AF measuring beam control with connecting cable SCA 3045 Flash readiness indication in camera’s viewfinder or camera display Correct exposure indication in camera’s viewfinder or camera display Automatic flash sync speed control 1st/2nd curtain synchronisation (REAR; 2nd curtain)) Slow synchronisation (Slow) High-speed synchronisation (HSS)
Standard foot SCA 301 or
SCA SCA 300 - System
SCA 3002 - System
Availability depends on the given camera system (camera manufacturer), the specific type of camera and the SCA adapter. For more detailed information ple- ase refer to the SCA Survey Table or the respective SCA Adapter Operating Instructions.
A multitude of additional functions become available when the mecablitz 45CL- 4 digital is operated with an SCA adapter of the SCA 3002 or SCA 300 sys- tem. This requires the connecting cable SCA 3045 (SCA 3002 and SCA 300 adapter) or the connecting cable SCA 300A (only SCA 300 adapter) as an optional accessory!
Synch cable 45-47

above). Warranty claims for faults and damage to the flash unit arenot
Do not use lithium cells! Their higher voltage would damage the flash
Press the two locking keys of the battery holder (optional extra) and pull the
holder out of the flash unit (Fig 4a). To return the battery holder insert it into
the flash unit’s handle-mount grip and press it until it audibly locks in place.
Press together the two smooth locking keys of the dismantled battery holder
(optional extra) and remove the lid (Fig. 4b). Insert new batteries in confor-
mity with the polarity symbols indicated on the bottom of the holder. Return
Mixed up battery poles may destroy the flash unit.. Replace all batte-
ries at a time and make sure that the batteries are of the same brand
thrown into the domestic waste! Help keep the environment clean and
We therefore recommend that you store the battery pack at a temperature
unit’s electronic system. Only use the permitted power sources (see
accepted if they were caused by the use of accessories from other
and type and have the same capacity! Spent batteries must not be
4.1.1 Battery notes • The battery pack must be charged before it is used for the first time.
discard spent batteries at corresponding collecting points.
4.1 Operation with NiMh Battery Pack 45-56
destroy the battery pack.
the lid and lock in again.
manufacturers.
Be sure to switch off the flash unit by its main switch prior to mounting
or removing the connecting components! Before mounting or removing
The flash unit can be attached to the camera and operated with:
the flash unit, switch off both the camera and the flash unit!
- an SCA 3xx2 adapter 1) and a synch cable SCA 3045 1).
- a standard foot 301 1) and a synch cable SCA 300A 1)
- an SCA 3xx adapter 1) and a synch cable SCA 300A 1)
Attaching the flash unit to the camera
the 70-35 bracket (optional extra).
The flash unit can be operated with:
Mounting the flash unit:
- a synch cable 45-47.
Exchanging the batteries · Battery replacement

pack). The charging operation starts automatically. The status of the
> LED lights with green light: the battery pack has been fully charged
connecting and disconnecting the connecting cable or the Power Pack!
4.2 Operation with Power Pack P50 or P76 If the number of flashes and recycling times are not sufficient for your given
application, then the flash unit can be powered with the Power Pack P50 or
socket with the V50 or V76 connecting cable (optional extra). This does
A loaded battery holder or battery pack can remain in the flash unit.
To connect the Power Pack or the connecting cable V50 or V76 to the flash
unit the main switch of the flash unit must be pushed down into its lower
The flash unit will then be switched on and off with the switch on the Power
To protect the flash unit from overheating when it is operated with a
intensive use! Ensure that all affected devices are switched off before
P76 (optional extra). The Power Pack is connected to the flash unit via the
Power Pack, a monitoring circuit lengthens the recycle time during
> LED lights with red light: the battery pack is being charged.
not require the use of the battery holder 45-39 or the NiMh Battery
move the ribbed slide on the battery cover to the black position.
move the ribbed slide on the battery cover to the white position.
and the charger has switched to trickle-charge mode.
battery charger is indicated by a two-colour LED.
Pack (see Operating Instructions for the Power Pack).
Identifying a fully charged battery pack 45-56:
shorter for a partially discharged battery pack.
Identifying a discharged battery pack 45-56:
Pack 45-56 inside the flash unit.
position (OFF).
the mains socket, release the currently installed adapter by pressing the key a
separately. If it is charged in the flashgun, the flashgun must be switched off !
the flash unit! The battery must only be charged with the original Metz
The charging operation is monitored by a microcontroller in the battery char-
nated automatically and the battery charger switches to trickle-charge mode.
the battery pack for a long period, you should disconnect it from the
4.1.2 Connecting the charger to the mains The charger is supplied complete with interchangeable adapters for different
socket with the aid of a mains cable (not included) which is inserted into the
DO NOT switch on the flash unit while the battery is being charged in
The battery pack is exhausted if the recharging time after a full-power flash
ger. When the battery pack is fully charged, the charging operation is termi-
You can leave the battery pack connected to the charger in order to
charging and the charging time is also limited by a timer. The charging time
mains sockets (Fig. 5). To change the adapter, disconnect the charger from
ensure continuous readiness. However, if you do not intend to use
For safety reasons, the temperature of the battery pack is monitored during
is about 2.5 hours for a fully discharged battery pack and correspondingly
With no adapter fitted, the battery charger can be connected to a mains
battery charger envisaged for this purpose! DO NOT use any other
4.1.3 Charging the batteries The NiMH battery pack 45-56 can be charged either in the flashgun or
(e.g. in manual flash mode M) exceeds about 60 seconds.
and at the same time pull off the adapter y (Fig. 6).
integrated mains connection socket (Fig. 7).
of 2 °C to 8 ° C (e.g. in a refrigerator).
charger.
charger!

range. The subject should be located in the middle third of the indicated ran-
the flash unit when the latter is operated with an adapter from the SCA 3002
The automatic setting range for ISO extends from ISO 6 to ISO 6400.
6.1 Automatic flash mode In the automatic flash mode A the sensor measures the light reflected by
We recommend the camera mode aperture priority (A, Av) or manual
The aperture and ISO sensitivity of the camera can be automatically set on
The maximum flash range can be read off the setting mark of the selector
disk. The shortest shooting distance is approx. 10% of the maximum flash
The automatic setting range for the aperature extends from f/1.0 to
the subject. The flashlight is turned off by the flash unit’s electronic circuit
f/45 (at ISO 100 / 21°), including all the in-between values.
when the amount of light is adequate for the given exposure.
ge to give the electronic circuit leeway for compensation.
Automatic setting of the ISO value and aperture
(M).
system:
depends on the adjusted parameters (ISO / aperture / partial light output).
The adjusted flash mode is indicated on the display window. The flash rea-
diness indicator lights up when the flash unit is ready for operation. The
secondary reflector is turned off when the switch is in the bottom position.
being used the camera will automatically switch over to flash synch speed
the given camera and SCA adapter). The setting is made with the “Mode”
Push the switch into the top position. When in the middle position the
adapter is used a corresponding indication is given in the camera’s view-
flash unit is switched off when the main switch is in the lower position.
secondary reflector will only emit approx. 50% of its light intensity. The
automatic flash mode or with manual partial light output the flash fired
key . The adjusted flash mode is indicated on the indicator window.
ture, TTL mode or M manual mode, or a manual partial light output.
finder or on the camera display, depending on the camera type.
should this be necessary.
Setting procedure

camera’s electronic system is via an adapter from the SCA 3002 system. The
Many modern camera models, but particularly many digital cameras,
established with one or more preflashes prior to exposure and evaluated by
the camera’s electronic circuit. The distance data from the camera’s AF sys-
Minolta ADI, Nikon D-TTL, Nikon iTTL etc.). These are further develop-
ments of the standard TTL flash mode which is not supported by these
6.3 TTL flash mode with preflash In TTL flash mode with preflash the reflective properties of the subject are
cameras. For further details please refer to the camera’s operating
tem can be additionally taken into account. Light output control by the
only support the TTL flash mode with preflash (e.g. Canon E-TTL,
preflash mode is selected with the ‘”Mode” key .
instructions.
flash unit automatically takes over the data for the aperture and ISO setting
indicator window. When the camera’s shutter release is lightly touched the
from the camera. The values for auto working aperture and ISO manually
For manual adjustment of the ISO and aperture (e.g. with fill-in flash)
continue depressing the “Mode” key until only “A” is displayed on
of the SCA 300 system can be connected to the flash unit with the connec-
The maximum flash range can be read off directly from the aperture calcula-
manually set on the flash unit. The shortest shooting distance is approx. 10%
third of the indicated range to give the electronic circuit leeway for compen-
The aperture or ISO value does not have to be set on the flash unit for
light reflected by the subject. This means that light measurement also takes
mounted filters into account. When an adequate amount of light has been
reached the camera’s electronic circuit switches off the flash by way of the
In TTL flash mode the camera’s sensor measures through-the-lens (TTL) the
of the maximum flash range. The subject should be located in the middle
tor under the f-stop when the ISO value of the camera or film has been
ting cable SCA 3045 or the connecting cable SCA 300A.
adjusted on the flash unit are irrelevant in this context.
the TTL flash mode to function!
the display window.
6.2 TTL flash mode
SCA adapter.
sation.
Setting procedure · Setting procedure

(M). The adjusted aperture must be corrected when a wide-angle diffu-
ser is used. The setting centre on the flash head automatically takes the
50 MZ5, 54 MZ-..., 70 MZ-..., 76 MZ-...) on the camera provides cordless control of light output of one or more slave units in TTL or automatic flash
TTL flash modes with preflash (ADI, E-TTL, D-TTL, i-TTL etc.) are not sup-
Please note that the mecablitz 45 CL-4 digital only supports the remote
We recommend the camera mode aperture priority (A, Av) or manual
6.5 Slave mode in the cordless Metz Remote System When in the cordless Metz Remote System a controller flash unit (40 MZ-...,
The mecablitz 45 CL-4 digital supports the slave mode in the cordless Metz
Remote System. For this purpose, the flash unit must be equipped with a sla-
ve adapter SCA 3083 digital (optional extra). The slave adapter is connec-
channel “Ad1” of the controller! For further details relating to the sla-
ve mode please refer to the operating instructions for the slave adap-
The scale of the aperture calculator indicates, above the given lighting dis-
ted to the flash unit with the connecting cable SCA 3045 (optional extra).
the flash unit. “M” lights up on the indicator window of the flash unit.
flashes additionally when flash readiness is reached.
tance, the aperture that has to be set on the camera.
mounted wide-angle diffuser into account.
ported for system-inherent reasons!
mode.
The maximum flash range can be read off directly from the aperture calcula-
manually set on the flash unit. The shortest shooting distance is approx. 10%
third of the indicated range to give the electronic circuit leeway for compen-
The aperture or ISO value does not have to be set on the flash unit for
the TTL flash mode with preflash to function! All flash modes, with the
exception of high-speed synchronisation (HSS), are also supported by
6.4 Manual flash mode M The flash unit emits the full uncontrolled amount of light in the manual mode
situation may then be achieved with a corresponding aperture setting on the
if no partial light output has been selected. Adaptation to the photographic
Adapter Camera system Flash modes Display panel
TTL BL
TTL BL
of the maximum flash range. The subject should be located in the middle
tor under the f-stop when the ISO value of the camera or film has been
TTL
TTL
SCA 3402 Nikon „Matrix-controlled fill-in flash“
SCA 3302 Minolta “Preflash control” / “ADI“
SCA 3402 Nikon „3D multi-sensor-fill-in flash“
SCA 3402 Nikon i-TTL BL / D-TTL-3D
SCA 3102 Canon E-TTL / E-TTL II
SCA 3202 Olympus TTL with preflash
SCA 3402 Nikon i-TTL / D-TTL
the secondary reflector of the flash unit.
sation.
camera.

The aperture f/5.6 has been set on the camera. The aperture f/4 is manually
correction value of approx. 1 f-stop is set on the camera for the flash during
Exposure correction in TTL flash mode must be set on the camera (see opera-
An f-stop which differs from the camera aperture is set manually on the flash
Dark subject against a bright background: Set on the flash unit an f-stop that
Bright subject against a dark background: Set on the flash unit an f-stop that
the camera during automatic data transfer (ISO, aperture). An additio-
With an adapter from the SCA 3002 system and an appropriate camera a
Extreme contrast differences between subject and background can confuse
the automatic exposure system of the camera or flash unit. This can be com-
with a corresponding camera, the correction value for flash is set on
automatic data transfer (ISO, aperture). An additional setting on the flash
When an adapter from the SCA 3002 system is used in conjunction
unit for Exposure correction in automatic flash mode.
nal setting on the flash unit is then unnecessary!
Positive correction value (approx. +1 to +2 f-stops).
Negative correction value (approx. -1 to -2 f-stops).
Dark subject against a bright background:
Bright subject against a dark background:
pensated by manual exposure correction.
ting instructions for the given camera):
set on the flash unit for fill-in flash.
unit is then not necessary!
on the flash unit f/5.6.
on the flash unit f/2.8.
Example:
Bounce flash illuminates the subject more softly and dense shadows are dimi-
The main reflector of the flash unit can be swivelled horizontally and verti-
cally for bounce flash. To avoid colour cast bounce the flash off a colour-neu-
The main reflector and the secondary reflector cover focal lengths as of
tem is being used then manual aperture setting must be selected on the
tral or white surface. The secondary reflector can be additionally activa-
35mm. The wide-angle diffuser (45-42) (included with the flash unit) widens the illumination of the main reflector for focal lengths as of 28mm (35 mm
in Program or Auto Mode. Various camera models additionally feature spe-
cial TTL fill-in flash programmes that can be activated on the camera (see the
Av) or in manual mode M. When an adapter from the SCA 3002 sys-
nished. Moreover, the physically conditioned decline of light from the fore-
format in all cases). The wide-angle diffuser diminishes the guide number,
and thus the maximum flash range, by approx. 30%. This is automatically
9.1 TTL fill-in flash Most camera models automatically support the TTL fill-in flash control when
9.2 Automatic fill-in flash When in automatic fill-in flash mode the auto working aperture of the flash
unit is opened by approx. one stop increment further than the f-stop set on
We suggest setting the camera in the aperture priority mode (e.g. A,
Please note that bounce flash reduces the maximum flash range!
flash unit if corrections cannot be entered on the camera!
operating instructions for the given camera and SCA adapter).
adapted by the aperture calculator on the flash head.
ted with the switch for fill-in frontal lighting.
ground to the background is reduced.
8. Illumination
9. Fill-in flash
the camera.

When using an SCA adapter from the SCA 3002 system in conjunction with
lighting conditions. A strip pattern is projected onto the subject to enable the
modes, then switch off the flash unit for about 10 seconds by its main switch.
The red-eye effect becomes apparent when a person is looking straight into
the camera, the ambient lighting is poor and the flash unit is located in the
immediate vicinity of the camera. Under these circumstances the pupils are
the red-eye effect. This function is set on the camera (see operating instruc-
approx. 0.7 m and 6 to 9 m (for further details please refer to the operating
Check the camera settings and find out if the SCA adapter or the flash unit’s
To set high-speed synchronisation continue depressing the “Mode” key
One or more preflashes induce the pupils to close down, thereby reducing
given camera model, the AF measuring beam function is activated in poor
The flash unit must operate properly when it is switched on again. Contact
the SCA 3045 connecting cable (optional extra), and depending on the
AF system to focus the camera lens. The distance range depends on the
speed of the lens. With a standard lens the effective range is between
Should, for example, the flash unit not work properly in the individual
Replace the old batteries or rechargeable battery packs by new ones.
wide open so that the flash illuminates the red retina of the eyes.
foot is correctoy mounted in the camera’s accessory shoe.
instructions of the given camera and SCA adapter).
tions for the given camera and SCA adapter).
until “HSS” appears in the indicator window.
your local dealer should this not be the case.
camera and SCA adapter).
exposure time for a more “natural” rendition of the exposure situation in con-
setting has to be selected on the flash unit if a correction value cannot be set
11.1 Normal synchronisation With normal synchronisation the flash unit is fired at the beginning of the expo-
11.3 Slow synchronisation Slow synchronisation can be selected on many cameras when an SCA adap-
ambient light conditions so that in darkness greater emphasis will be placed
speeds faster than the flash synch speed. For instance, HSS makes it possible
background. HSS is supported in TTL flash mode and/or manual flash mode
M, depending on the camera model (see operating instructions for the given
When an adapter from the SCA 3002 system is used the manual aperture
junction with slow shutter speeds (>1/30 s) and moving light sources. The
light traces in the exposure then follow the light source. The setting is made
on the camera. For further details please refer to the operating instructions
11.4 High-speed synchronisation HSS In conjunction with an adapter from the SCA 3002 system, some cameras
sure time (synchronisation with the first shutter curtain). This is the standard
mode with all cameras. A corresponding setting is therefore not necessary.
11.2 2nd curtain synchronisation Many cameras support 2nd curtain synchronisation (rear, 2nd curtain) in
conjunction with an SCA adapter. The flash unit is fired at the end of the
ter is used. The camera will then adapt the shutter speed to the prevailing
on the background. The setting is made on the camera. For further details
selecting a wide open aperture to clearly contrast the portrait against the
to minimize the depth-of-field in portraiture with bright ambient light by
will support high-speed synchronisation (HSS) for flash shots at shutter
refer to the operating instructions for the camera and SCA adapter.
for the given camera and SCA adapter.
on the camera!

* approx. 200 with NiMh batteries 45-56 * approx. 170 with high-capacity alkaline manganese batteries * approx. 300 with Power Pack P50 * approx. 400 with Power Pack P76 (all at full light output)
* approx. 4 sec. with high-capacity alkaline manganese batteries * approx. 4 sec. with NiMh batteries 45-56 * approx. 3 sec. with Power Pack P50 / P76 (all at full light output)
... with wide angle diffuser, as of 28 mm (35 mm format)
Swivelling ranges and locking positions of main reflector
ISO 6 to ISO 6400 for automatic setting (SCA 3002)
Secondary reflector, as of 35 mm (35 mm format)
Main reflector, as of 35 mm (35 mm format)
upwards 15° 30° 45° 60° 75° 90°
ISO 25 to ISO 1000 for manual setting
Dimensions approx. in mm (w x h x d)
Flash unit 92 x 247 x 102
Number of flashes:
Recycling time:
Sensitivity:
Weight:
The flash capacitor incorporated in the flash unit undergoes a physical chan-
ge when the flash unit is not switched on for prolonged periods. For this rea-
son it is necessary to switch on the flash unit for approx. 10 minutes every 3
TTL, TTL modes with preflash (see Table 1), Auto Mode A, Manual Mode M,
Remove any grime and dust with a soft, dry or silicon-treated cloth. Never
months. The batteries must supply sufficient power for flash readiness to be
f1.0 to f45 (at ISO 100 / 21°) including in-between values (SCA 3002)
indicated within 1 minute after the flash unit was switched on.
* approx. 1/125 ... 1/20000 sec. * in M mode approx. 1/125 sec. with full light output * with 1/2 light output approx. 1/800 sec. * with 1/4 light output approx. 1/2000 sec. * with 1/8 light output approx. 1/3500 sec. * with 1/16 light output approx. 1/6000 sec. * with 1/32 light output approx. 1/10000 sec Coverage of sensor: approx. 25°
use detergents – they may damage plastic parts.
f2.8 – f4 – f5,. – f8 – f11 – f16 at ISO 100 / 21°
Manually adjustable auto apertures:
Guide numbers at ISO 100/21°:
Automatic aperture setting range
Forming the flash capacitor
Flash durations:

accessories from other manufacturers are not covered by our guaran-
Instructions. Connecting cable SCA 300A (Order No. 0000930) or con-
Malfunctions and damage caused to the flash unit due to the use of
the SCA functions. Extended functional features compared with the SCA
camera-triggered flash. Responds also to infrared light beam. Does not
300 system. The SCA 3045 connecting cable is additionally required.
necting cable SCA 3045 are additionally required.
require batteries.
coloured foil.
operation.
tee.!
Flash unit, camera bracket, battery pack 45-56, charger, synch cable 45-47,
wide-angle diffuser 45-42, operating instructions.
These table does not apply to bounced flash.
Battery charger 970 · Battery pack 45-56 · Included

country. Please return only fully discharged batteries. Normally, batteries are
To ensure short-circuit safety please cover the battery poles with adhesive
Please return spent batteries to collecting points should they exist in your
Do not dispose of spent batteries with domestic rubbish.
fully discharged if:
tape.
gives your pictures a marvellous soft appearance, while the tone of skin is
rendered faithfully. The maximum working range is diminished by the fac-
Remote System, for optical simultaneous triggering and optical triggering
with preflash suppression for digital cameras. The SCA 3045 connecting
flashes). To connect the P 76, the V76 connecting cable (Order No.
Coiled synch lead 45-54 for hot shoe (Order No: 000045542)
Synch extension lead 60-54 (5 m) (Order No: 000060541)
cable is additionally required (Order No. 0030450).
Synch lead 45-48, 1 m (Order No: 000045480)
tor 2 in conformity with the loss of light.
0000376) is additionally required.
cameras with hot shoe contact.
angle shots.
Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.
Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.