Gebruiksaanwijzing /service van het product FR-D700 van de fabrikant Mitsubishi Electronics
Ga naar pagina of 11
INVERTER FR-D700 Safety stop function instruction manual CONTENTS 1. General description ............................................................................. 1 2. Inst allation and wiring ......................................................
Compliance with the EU Machinery Directive – Functional Safety DANGER Any misuse of safety function could lead to personal injury or death , property damage, or economic loss. To ensure that the system complies full y with require ment of safety, make a system-level ri sk assessment.
1 1. General description Features Mitsubishi FR -D700 safety stop function prevent s a drive from supplying rot ational energy to motors. Dual safety channels ‘S1’ and ‘S2’ cut of f the gate-drive power for IGBT to turn off.
2 2. Inst allation and wiring ATTENTION The following information is merely a guide for prope r installation. Mitsubishi Electric Co. cannot assu me responsibility for the compliance or the noncomplia nce to any code, national, local or otherwise for the pro per installation of this equipment.
3 Wiring The safety related terminals are d escribed in T able.2 and T able.3 T able.2 The safety related terminals T able.3 T ruth table of Safety related signals Input power S1-SC S2-SC Failure SO-S.
4 Wire and ferrule specification T able.4 wire and ferrule specification Wire size (mm 2 ) Ferrule with insulation collar * Crimping tool * 0.3 / 0.5 AI 0,5-10WH 0.75 AI 0,75-10GY 1 AI 1-10RD 1.25 / 1.5 AI1,5-10BK 0.75 (combined 2 wire) AI TWIN 2 X 0,75-10GY CRIMPFOX ZA3 *Ferrules and tools are dist ributed by Phoenix Conta ct.
5 3. Example of safety system configuration Example 1 Fig.3 Safety system example 1 – STOP asynchronous with EM and fault detecti on through A-C output. For safety stop, configure the wiring as shown in Fig.3 above. Note: the above wiring is configured to prevent resta rt in case of a fault.
6 * When connecting multiple i nverters, use a diode on the eac h safety input terminal to preve nt a malfunction due to undesirable current. Fig.4 Example of multiple inverters connected to a safety .
7 Example 2 Fig.5 Safety system example 2 – STOP synchronous with EM and fault detectio n through RUN output. For safety stop, configure the wiring as shown in Fig.4 above. Note: the above wiring is configured to prevent resta rt in case of a fault.
8 4. T est and checking failure ATTENTION T o avoid systematic faults, a test even for faulty demands of the safety function has to be performed in order to check the correct function of the monitor signal. This test shall be carried out at system installation, any software changes, parameterization changes, and/or at least once per year .
REVISIONS Print Date Manual Number Revision Aug. 2009 BCN-A211508-000- C First edition Dec. 2009 BCN-A211508- 000-D Change Example of Safety stop conne ction.
Een belangrijk punt na aankoop van elk apparaat Mitsubishi Electronics FR-D700 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Mitsubishi Electronics FR-D700 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Mitsubishi Electronics FR-D700 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Mitsubishi Electronics FR-D700 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Mitsubishi Electronics FR-D700 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Mitsubishi Electronics FR-D700 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Mitsubishi Electronics FR-D700 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Mitsubishi Electronics FR-D700 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.