Ga naar pagina of 14
INVERTER FR-D700 Safety stop function instruction manual CONTENTS 1. General d escrip ti on ............................................................................ 1 2. Inst allat i on and wirin g .................................................
Compliance with the EU Machinery Directi ve – Functional Safety WARNING Any m isuse of safet y function cou ld lead to person al in jur y or de ath, prop erty dam age, or econom ic loss. To ens ure that the s ystem com plies f ully with r equirem ent of safet y, mak e a s y stem -level r isk as sessm ent.
1 1. General description Features Mitsubishi F R-D70 0 safet y stop func tion pre vents a drive f rom supplying rotati onal ener gy to m otors . Dual saf ety channels ‘ S1’ a nd ‘S2’ cut off the gate-drive po wer for IGBT to turn off.
2 2. Inst allation and wiring CA UTION The f ollowing inform ation is m erely a guid e for proper i nstal lation. Mitsubis hi Electr ic Co. ca nnot ass um e responsibi lit y for the com pliance or the nonc om pliance to any code , national, local or other wise for the prop er inst allat ion of this equ ipment.
3 Wiring The s afety relat ed term inal s are desc ribed i n T able.2 a nd T able.3 T able.2 T he safet y related t erm inals T erm inal Sy m bol Descrip tion Rating S1 For input of s afety stop cha nnel1. S1-SC is Open: In saf ety stop mode. Short: Non sa fety stop mode.
4 T able.3 Truth table of Safet y relate d signa ls Input power S1-SC S2-SC Internal safety circuit faul t *1 SO (SAFE) RUN or A-C (SAFE2) *2 *3 Drive st ate OFF - - - OFF(Open) OFF(Open) Drive shutof.
5 3. Example of safety system configuration Example 1 S2 S1 SC FR-D700 ST ART +24V K1 A(SAFE2) CPU X0 X1 COM0 COM1 24G Internal Safety Circuit XS0 XS1 Z1 0 Z00 Z20 Z11 Z0 1 Z21 K2 DC24V RY B C QS90SR2.
6 START +24V K1 X0 X1 COM0 COM1 24G Internal Safety Circuit XS0 XS1 Z10 Z00 Z20 Z11 Z01 Z21 K2 DC24V QS90SR2SN-Q MITSU BISHI MEL SEC Safety rel ay module S2 S1 SC FR-D 700 A(SAFE2) CPU RY B C U V W Ga.
7 • Example when using multiple FR-D700 inverters manufactured in December 2010 or before ST ART Emergency stop button +24V K1 X0 X1 COM0 COM1 24G Internal Safety Circuit XS0 XS1 Z10 Z00 Z20 Z11 Z01.
8 Example 2 S2 S1 SC FR-D 700 ST ART +24V K1 CPU X0 X1 COM0 COM1 24G Internal Safety Circuit XS0 XS1 Z10 Z00 Z20 Z11 Z01 Z21 K2 DC24V RUN (SAFE2) QS90SR 2SN-Q MITSUB ISHI MEL SEC Safety r elay module Gate Driver Gate Driver SE STF STOP STF STOP PC* +24V +24V GG * If the control logic is SINK logic, the common terminal is terminal SD.
9 4. T est and checking fai lure CA UTION T o avoid syst ematic faults , a te st even for fa ulty demands of t he safety funct ion has to b e performed in order to check the correct fu nction of the mon itor signal.
10 5. Safety p arameters of FR-D700 FR-D700 saf et y related I/O status obe ys the foll owing tr uth table. T able.6 S afet y parameters of FR-D 700 Parameter V alue PFD AV G 2.
11 REVISI ONS Print Dat e Manual Num ber Revision Aug. 2009 BCN-A211508-000-C First edit ion Dec. 2009 BCN-A211508- 000-D Change Example of Saf ety stop conne ction Jan. 2010 BCN-A211508- 000-E Addition Diode specif ication for multiple connection Jul.
HEAD OFF ICE: TOKYO BUILDING 2-7-3, MARUN OUCHI, CHIYODA -KU, TOKYO 100- 8310, JAP AN MITSUBISHI ELECTRIC EUROPE EUROPE B.V . German Branch Gothaer Straße 8 D-408 80 Rat ingen Phon e: +49 (0) 21 02 / 486- 0 Hotline: +49 21 02 180 5 000- 765 /-766 Fax: + 49 (0) 21 02 / 4 86-1 12 0 e mail: megfa-mail@m eg.
Een belangrijk punt na aankoop van elk apparaat Mitsubishi Electronics FR-D700 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Mitsubishi Electronics FR-D700 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Mitsubishi Electronics FR-D700 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Mitsubishi Electronics FR-D700 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Mitsubishi Electronics FR-D700 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Mitsubishi Electronics FR-D700 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Mitsubishi Electronics FR-D700 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Mitsubishi Electronics FR-D700 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.