MELSEC System Q Progr ammab le Logic Controllers User's Manual De viceNet Master -Sla ve Module QJ71DN91 GX Configurator -DN INDUSTRIAL AUTOMATION MIT SU BI S HI ELE C TRI C MI T SU BI S HI ELE C TRI C Art.
A - 1 A - 1 • SAFETY PRECAUTIONS • (Always read these instruct ions before using this equipment. ) Before using this product, please read t his manual and the relevant manuals introduced in this ma nual carefully and pay full attention t o safety to handle the product correctly.
A - 2 A - 2 [INSTALLATI ON PRECAUTI ONS] ! CAUTION • Use the PLC in an env ironment t hat meets the general specificat ions contain ed in t he CPU User's Manual to use.
A - 3 A - 3 [CAUTIONS ON STA RTUP AND MAINTENANCE] ! DANGER • Alw ays turn off all external power supply phases before touching any terminals. Failure to do this may result in malfunction. • Alw ays turn of all external pow er supply phases before cleaning or tightening the t ermina l screws.
A - 4 A - 4 REVI SION S The manual number is given on the bottom left of the back cover. Pri nt Da te Manual Num ber Revision Dec., 2000 SH (NA)-0 80143- A Firs t Prin ting Jun., 2001 SH (NA)-0 80143-B Addition Section 2 .3, 2.4 Delete Section 2 .2.1, 2.
A - 5 A - 5 INTRODUCT ION Thank you for purc hasing the M ELSEC-Q s eries PLC. Before us ing t he equipm ent. pl ease re ad this m anual caref ull y to develo p full fam iliarit y with th e functi ons and perf ormanc e of the Q s eries PLC you h ave pur chased, s o as to ensure cor rect us e.
A - 6 A - 6 4 SETUP AN D PROC ED URE S BEFO RE OP ERAT ION 4- 1 to 4- 14 4.1 Set up a nd Pr ocedures bef ore O perat ion ...................................................................................... .......... 4- 1 4.1.1 W hen using th e m aster f uncti on .
A - 7 A - 7 7 PROGRA MMING W HEN EXECUTING T HE MAST ER FUNCT ION 7- 1 to 7- 12 7.1 Pr ecaut ions o n Pro gram ming ................................................................................................. ................. 7- 1 7.2 S ystem Configur atio n .
A - 8 A - 8 Conform ation to the EMC Dir ect ive and Lo w Volt age Instr ucti on For deta ils on m ak ing Mitsub ishi PL C confor m to the EMC d irective and l ow vol tage ins tructio n when installin.
A - 9 A - 9 Product Conf ig urati on The f ollowing is a lis t of th e com ponents in th is pro duct c onfigur ation. Model n ame Product name Quantit y QJ71DN91 DeviceN et m aster- slave m odule 1 Te.
1 - 1 1 - 1 MELSEC-Q 1 OVERVIE W 1 1 OVERVIEW This manua l ex plains th e spec if icatio ns and nam e of eac h com pone nt of the QJ71D N91 D evic eNe t mas ter/s lav e modu le, whic h is us ed in com bina tion wit h the MELS EC -Q Series PLC CPU. Ple a se see Device Ne t Sp e ci fic atio n Ma nu al (Rel ea se 2.
1 - 2 1 - 2 MELSEC-Q 1 OVERVIE W 1 (4) W hen the m odule f unct ions as a m aster node of D evice Net, I/O com m unicatio n and m essage com munic ati on with a De viceNet sl ave node a re possi ble. (5) W hen the m odule f unc tions as a m ast er no de of Devic eNet, the m odu le ca n communi ca t e with a maxi mu m of 63 slav e no de s.
2 - 1 2 - 1 MELSEC-Q 2 SYSTEM CONFIGURATION 2 2 SYSTEM CONFIGURATION This chapt er ex pla ins th e s ystem confi gurat ion of De vic eNet. 2.1 Overal l Configur ati on A tot al of 6 4 m odules incl udin g a m aster node , s lave n odes and a m aster/sl ave node can be con necte d.
2 - 2 2 - 2 MELSEC-Q 2 SYSTEM CONFIGURATION 2 (1) Net work specif ication The f ollow ing ex plai ns t he ne twork spec ific atio ns of De viceN et t hat us es th e QJ71D N91. (a) C omm unic ation s pee d The c omm unicat ion s peed can b e sel ected f rom 125k baud , 250k baud , or 500k baud us ing t he m ode s witc h of the QJ 71D N91.
2 - 3 2 - 3 MELSEC-Q 2 SYSTEM CONFIGURATION 2.2 Applicable Sy stems This sect ion d escri bes th e sys tem conf igur atio n for t he Q J71DN 91. (1) Appli cabl e modul e and th e nu mber o f modules t.
2 - 4 2 - 4 MELSEC-Q 2 SYSTEM CONFIGURATION (4) Software packag es suppor ted Corres pond ence b etwe en sys tem s whic h us e QJ7 1DN91s a nd sof twar e pack ages ar e as s how n belo w.
2 - 5 2 - 5 MELSEC-Q 2 SYSTEM CONFIGURATION (2) How to check the GX Configuration-DN software v ers ion The GX Conf igura tor-D N sof tware vers ion c an b e chec ked in GX Dev elo per's "Prod uct inf orm ation" screen .
2 - 6 2 - 6 MELSEC-Q 2 SYSTEM CONFIGURATION 2.5 About Additional Functi on The a dd ed func ti on is de scr i bed bel ow . Function Serial No. Function Outline Reference Section Addition of Each Node Communicat ion Error Status (addresses 01C0 H to 01C3 H /448 to 451) First five digits of serial No.
3 - 1 3 - 1 MELSEC-Q 3 SPECIFICATIONS 3 SPECIFICATIONS 3.1 Performance S peci fications This sect ion ex pla ins th e per form anc e spec ific at ions f or QJ 71D N91, I /O s igna ls f or PLC CP U an d sp e cifi c at io n s for bu ffe r me mory . See t he PLC CPU User's Ma nual t o be used f or the gene ra l spec ific ati ons for QJ71D N91.
3 - 2 3 - 2 MELSEC-Q 3 SPECIFICATIONS 3.2 Functions This sect ion ex pla ins th e func tions of th e QJ 71DN9 1. 3.2.1 Master function (I/O communication f unction) The I/O c om munic atio n func tion ex ecut es t he I/O dat a comm unic atio n wit h each sla ve node.
3 - 3 3 - 3 MELSEC-Q 3 SPECIFICATIONS (2) W hen the se quenc e pro gram is used The f ollowi ng exp lains the I/O c omm unicat ion f unct ion whe n the s equ ence progr am is used.
3 - 4 3 - 4 MELSEC-Q 3 SPECIFICATIONS (3) Overview of each connection ty pe The f ollowi ng exp lains an overv iew of each connec tion type use d dur ing t he I/O communi cation.
3 - 5 3 - 5 MELSEC-Q 3 SPECIFICATIONS (b) Bit strobe As sh own in th e fo llowin g dia gr am, the com m unicati on m etho d b y whic h the com m unicati on with eac h sl ave no de is rep eate d, as descr ibed f rom 1) to 4), is th e bit stro be c omm unicat ion.
3 - 6 3 - 6 MELSEC-Q 3 SPECIFICATIONS (c) Change-of-state As sh own in th e fo llowin g dia gr am, the com m unicati on m etho d tha t execu tes th e com munic ation of [ 1] an d [2] as th e I/O data c ha nges is t he change- of- state c omm unic atio n, an d the c onn ection that uses this comm unic ation is t he cha nge- of-s tate c onnec ti on.
3 - 7 3 - 7 MELSEC-Q 3 SPECIFICATIONS (d) C y clic As sh own in th e fo llowin g dia gr am, the com m unicati on m etho d tha t regul arl y repea ts the com m unicati on of [1] and [2] is the c yclic comm unic ation, and t he c onnec tio n tha t uses this com m unicati on is the cycli c con nec tion .
3 - 8 3 - 8 MELSEC-Q 3 SPECIFICATIONS 3.2.2 Master function ( Messag e communi cati on function) The m ess age com m unicat ion func tion is us ed t o ge t and s et t he at tribu te da ta of a slav e no de .
3 - 9 3 - 9 MELSEC-Q 3 SPECIFICATIONS (2) Setting attributes Attribut e Attribut e PLC CPU QJ71 D N91 Slave n ode (MAC ID) SET Y12 X02 Message communication request 1) 2) Message commun ication comman.
3 - 10 3 - 10 MELSEC-Q 3 SPECIFICATIONS (3) Readi ng the communi cati on err or i nformation PLC CP U QJ 71DN91 Slave node ( MAC ID) SET Y12 X02 FROM Message commu nication re qu es t 1) 2) 5) Message.
3 - 11 3 - 11 MELSEC-Q 3 SPECIFICATIONS 3.2.3 Slave function (I/O commu nication function) The I/O c om munic atio n func tion ex ecut es t he com m unicati on of the I/O da ta with the mas ter node using the pol ling m ethod.
3 - 12 3 - 12 MELSEC-Q 3 SPECIFICATIONS (2) W hen the sequence program i s used The f ollowi ng exp lains the I/O c omm unicat ion f unct ion wh en th e se quenc e progr am is used.
3 - 13 3 - 13 MELSEC-Q 3 SPECIFICATIONS 3.3 I/O Signals for the PLC CPU This sect ion ex pla ins th e inpu t/out put s igna ls for the PLC C PU of the Q J71D N91. 3.3.1 I/O signal list The I /O sign al list fo r the QJ71 DN 91 is show n in Table 3 .2.
3 - 14 3 - 14 MELSEC-Q 3 SPECIFICATIONS 3.3.2 Details of the I/O signals The f ollowi ng d escrib es t he ON/O FF tim ings an d co nditio ns of th e I/O s igna ls. (1) W atc hdog T imer E rror: X0 0 This is tur ned O N when a n err or oc curs in th e QJ 71DN91 .
3 - 15 3 - 15 MELSEC-Q 3 SPECIFICATIONS (b) W hen the a uto st art is se t 1) The mod ul e ready ( X0 F ) is turn ed ON wh en th e pow e r i s tu rn ed ON, and t he pa ram eter c heck is ex ecut ed a utom atica ll y. 2) If the param eter c heck is s uccess ful, the I/O c omm unicat ion st arts and the I/O comm unic ating (X01) is turne d ON .
3 - 16 3 - 16 MELSEC-Q 3 SPECIFICATIONS (3) I/O Communicating : X 01, I/O Communication Req uest: Y11 (when the slave function is used) These s ign als ar e used to s tart t he I/O com munic ation of .
3 - 17 3 - 17 MELSEC-Q 3 SPECIFICATIONS (4) Message Communi cation C ompl etion: X 02, M essag e Communication Er ror Si g nal : X05, M essag e C ommunicati on Request: Y 12 Thes e sign als ar e us ed to ex ecut e th e m essage c omm unic ation.
3 - 18 3 - 18 MELSEC-Q 3 SPECIFICATIONS (5) Master Functi on For Error Set Sig nal : X03, Master Function For Error Rese t Re quest : Y13 Thes e sign als ar e us ed to i ndic ate a n err or wh ile ex ecutin g t he m aster f unct ion and to r eset the error c ode.
3 - 19 3 - 19 MELSEC-Q 3 SPECIFICATIONS (7) Savin g Param ete r To Flash ROM: X06 , Save P aram ete r To Fla sh ROM Compl etion: X 07, Sav e Parameter To Flash ROM Req uest: Y17 (w hen the master func.
3 - 20 3 - 20 MELSEC-Q 3 SPECIFICATIONS POINT (1) E ven if the s ave p aram eter to f lash RO M req uest (Y17) is turne d ON while the I/O com munic at ing (X0 1) is ON, save param eter to flas h RO M com plet ion (X07) is not tur ned ON .
3 - 21 3 - 21 MELSEC-Q 3 SPECIFICATIONS W hen the par am eter ch eck fails : I/O Co mmunica tio n Request (Y11) I/O Communicating (X01) Save Parameter To Flash ROM request (Y17) Save Parameter To Flas.
3 - 22 3 - 22 MELSEC-Q 3 SPECIFICATIONS (9) Slave Functi on For Error Set Si g nal: X08, Sl ave Functi on For Error Reset Request: Y18 Thes e sign als n otif y an err or oc curr ence d ur ing ex ecuti on of the s lave f unct ion and ar e use d to res et the er ror c ode.
3 - 23 3 - 23 MELSEC-Q 3 SPECIFICATIONS (12) Auto Config ur ation Ex ecuting: X14, Auto Configur ati on Compl eti on: X15, Auto Config urati on R eq uest: Y 15 Thes e sign als ar e us ed in order to se arch the s lav e nodes tha t are c onnec ted to the net work an d create par am eters autom atic all y.
3 - 24 3 - 24 MELSEC-Q 3 SPECIFICATIONS 3.4 Buffer Memory The buf fer m em or y transfers data bet ween t he QJ 71DN9 1 and the PLC C PU. The FR OM a nd T O instr uct ions of t he PLC CPU are us ed to rea d an d writ e th e buf fer me mory d at a in th e Q J71 DN9 1.
3 - 25 3 - 25 MELSEC-Q 3 SPECIFICATIONS Table 3.3 Buff er m emor y list ( 2/2) Address Usability Hexadecim al Decimal Item Des cri ptio n Mast er functi on Slave functi on W rite from the PLC CPU allowed? Reference se ction 05FC H 1532 Prese nt Li nk S can Time Displ ays the cu rren t link sca n tim e (modul e: ms).
3 - 26 3 - 26 MELSEC-Q 3 SPECIFICATIONS 3.4.2 Buffer mem or y detai l s This sectio n expla ins the det ails of the buf fer m emor y. (1) Message communication comm and (addresses 0110 H to 011F H /272 to 2 87) Use the TO instr uct ion to writ e the m es sage c omm unicat ion comm and.
3 - 27 3 - 27 MELSEC-Q 3 SPECIFICATIONS (c) T o re ad the c om munic ation error infor mati on of the slave no de 1) Us e the T O i nstruct ion to set the c omm and d ata in the "m essage communi ca tion co mman d" area . 2) Us e the s eque nce program to t urn O N th e mes sage c omm unica tion reques t (Y1 2).
3 - 28 3 - 28 MELSEC-Q 3 SPECIFICATIONS (2) Message communicati on resul t ( addresses 0120 H to 012F H /288 to 303) Once t he pr ocess ing b y th e "m essa ge com m unicat ion c omm and" is.
3 - 29 3 - 29 MELSEC-Q 3 SPECIFICATIONS Table 3.13 Res ult d ata f or o ther m es sage c omm unica tions Buffe r mem or y addr ess (hex adecim al ) Item Descri ptio n 0120 H Command numbe r FE H : Re fe r to De v iceN et Co mmon Serv i ce for .
3 - 30 3 - 30 MELSEC-Q 3 SPECIFICATIONS (c) Reading communication e rror informati on The c omm unicat ion error inf orm ation t hat was re ad is stor ed.
3 - 31 3 - 31 MELSEC-Q 3 SPECIFICATIONS 2) The De vic eNet gener al error co de l ist is sho wn in Tabl e 3. 15. Table 3.15 De viceNet gener al er ror c ode list Erro r code Hexadecim al Decimal Erro .
3 - 32 3 - 32 MELSEC-Q 3 SPECIFICATIONS (4) Master Function C ommunicati on Status ( address 01B0 H /432) The h igher and lower b ytes in dicate the f ol lowing m aster c omm unica tion status : (a) Higher b yte This byte indic ates the I/O com m unicat ion st atus of t he QJ 71DN 91 m aster functi on.
3 - 33 3 - 33 MELSEC-Q 3 SPECIFICATIONS (5) Maste r Functio n Fo r Erro r Inf orma tion (a ddre ss 01B1 H /433) The c omm unicat ion er ror c ode t hat was de tect ed is s tore d.
3 - 34 3 - 34 MELSEC-Q 3 SPECIFICATIONS [Bit O N tim ing] (a) W hen I/O com m unicat ion is star ted 1) If aut omatic star t has not b een s et W hen I /O C om m unic ati on Re quest (Y11) is turne d ON, pa rameter che ck is m ad e.
3 - 35 3 - 35 MELSEC-Q 3 SPECIFICATIONS (10) Each Node C ommu ni cation Er r or Status ( addr esses 1C 0 H to 1C3 H /448 to 451) Thes e addr esses s tore whet her an I/O comm unic ation err or has occ.
3 - 36 3 - 36 MELSEC-Q 3 SPECIFICATIONS (12) Dow n Node D etection D i sabl e Status (addr esses 01C C H to 01CF H /460 to 463) These ad dre sse s set wh et h er or no t the I/ O sign al , "sl av.
3 - 37 3 - 37 MELSEC-Q 3 SPECIFICATIONS Table 3.22 Param eter setti ng data ( 1/2) Buffe r mem or y addr ess (hex adecim al ) Item Descri ptio n 01D4 H to 01D6 H U s e pr ohib i ted — 01D7 H Consta nt scan Spec ifies to make th e link s can time constant .
3 - 38 3 - 38 MELSEC-Q 3 SPECIFICATIONS Table 3.22 Param eter setti ng data ( 2/2) Buffe r mem or y addr ess (hex adecim al ) Item Descri ptio n 0248 H to 024F H 1 5th no de set t ing Same as th e 1st.
3 - 39 3 - 39 MELSEC-Q 3 SPECIFICATIONS POINT (1) Wr ite "0" in the un nec essar y param eter are a when cr eating a param eter. Other wise, an err or m a y occur if th e pre vious data rem ains.
3 - 40 3 - 40 MELSEC-Q 3 SPECIFICATIONS (14) Auto con figur ati on operati on setti ng ( address 03F0h/1008) The au to conf ig uratio n t ype and the m ax imum detec tion n ode num bers ar e set as fol lows: 1) Hi gher byte Sets t he au to conf ig uratio n typ e.
3 - 41 3 - 41 MELSEC-Q 3 SPECIFICATIONS (15) Master Function For IO Addr ess Area (addresses 0500 H to 05FB H /1280 to 1531) The he ad a ddres ses and s izes ( in wor d m odule) of the " inpu t d.
3 - 42 3 - 42 MELSEC-Q 3 SPECIFICATIONS (19) Slave Functi on C ommunicati on Stat us ( addr ess 0600 H /1536) Thes e addr esses indic at e the I/O c omm unica tion s tatus of th e QJ7 1DN9 1 sla ve functi on. T he val ues list ed in T able 3.24 are s tore d acc ord ing to the s tatus of communi cation.
3 - 43 3 - 43 MELSEC-Q 3 SPECIFICATIONS (20) Slave Functi on For Err or Information ( address 060 1 H /1537) The com munic ati on error c ode when th e sla ve funct ion is us ed is stor ed.
3 - 44 3 - 44 MELSEC-Q 3 SPECIFICATIONS (22) Model N ame Di spl ay ( addr esses 0620 H to 0624 H /1568 to 1572) "QJ71 DN9 1" is sto red in AS CII co de .
3 - 45 3 - 45 MELSEC-Q 3 SPECIFICATIONS (25) H/ W Test Item Display Ar ea ( addr ess 062E H /1582) The tes t item num bers curr entl y in oper atio n dur ing t he ha rdwar e t est an d communi ca tion te st ar e sto red .
3 - 46 3 - 46 MELSEC-Q 3 SPECIFICATIONS Table 3.29 Co ntents of com m unicat ion tes t res ult Error cod e Co ntent s Detail ed c onte nts H andli ng m eth od 0001 H N ode n umb er duplic ate e rror There i s anothe r nod e i n th e netw ork whic h has th e same node num be r as the loc al node.
3 - 47 3 - 47 MELSEC-Q 3 SPECIFICATIONS (29) Master Function R eceiv e Data (addresses 0700 H to 07FF H /1792 to 2047) The da ta th at was rece ived f rom each sla ve node is store d. T he da ta ass ignm ent is sh own b elow. T he data is st ored in the wor d boun dar ies of the slav e no des.
3 - 48 3 - 48 MELSEC-Q 3 SPECIFICATIONS (30) Master Function Transmi t D ata (addr esses 0900 H to 09FF H /2304 to 2559) The da ta to be tr ansm itted to eac h sla ve no de is wri tten by t he TO instr uctio n. The da ta ass ignm ent is shown bel ow. The da ta is s tor ed i n the word boun daries of t he s lave nodes.
3 - 49 3 - 49 MELSEC-Q 3 SPECIFICATIONS (31) Slave Functi on R eceiv e D ata ( addresses 0B00 H to 0B3F H /2816 to 2879) The da ta rec eive d from the m aster n ode is st ored. T he da ta of the size that is s et by the "set ti ng area o f th e n u mbe r of slav e fun cti on recept io n by te s" be co mes val id.
3 - 50 3 - 50 MELSEC-Q 3 SPECIFICATIONS 3.5 Communicati on Per formance 3.5.1 Scan time The s can tim e re pres ents the tim e t o wait f or r espo nses f rom all no des after the QJ71D N91 st arts s endi ng req uests in th e po lling or bi t strob e com munic ation .
3 - 51 3 - 51 MELSEC-Q 3 SPECIFICATIONS 3.5.2 Communication cy cl e The c omm unicat ion c ycle is th e tim e inter val bet ween the m oment a poll ing or a bit stro be r eques t is s ent to a s lave node and the m om ent another requ est is se nt to th e sam e nod e.
4 - 1 4 - 1 MELSEC-Q 4 SETUP AND PROCED UR ES BEFOR E OPERATION 4 4 SETUP AND PROCEDURES BEFO RE OPERATION This c hapt er des cribes th e proc edur es up to s ystem star tup us ing th e QJ7 1DN9 1. 4.1 Setup and Procedur es be for e Operati on 4.1.1 When using the master function Start Perform a hardware test (mode 9) .
4 - 2 4 - 2 MELSEC-Q 4 SETUP AND PROCED UR ES BEFOR E OPERATION 4 4.1.2 When using the sl av e function Start Perform a hardware t est (mode 9). Set t o mode 3 to 5 . Use GX Configurator-DN? Set "auto com munication start settings" using GX C onfigurator-DN and load it to the QJ71DN91.
4 - 3 4 - 3 MELSEC-Q 4 SETUP AND PROCED UR ES BEFOR E OPERATION 4.1.3 When using both the master function and slav e function Start Perform a hardware t est (mode 9). Set t o mode 0 to 2 . Use GX Configurator-DN? Set "auto communication start settings" using GX Configurator-DN and load it t o the QJ71DN91.
4 - 4 4 - 4 MELSEC-Q 4 SETUP AND PROCED UR ES BEFOR E OPERATION 4.2 Loading and Inst al l ation The f ollowi ng sec tio n exp lains the pr ecaut ions when hand ling t he QJ 71DN 91 fr om the time the y are unpac ked un til th e y ar e inst alled .
4 - 5 4 - 5 MELSEC-Q 4 SETUP AND PROCED UR ES BEFOR E OPERATION 4.3 Component Nam es and S etti ng s The f ollowi ng sec tio n desc ribes th e com pone nt nam es of the QJ 71 DN91, the meanin gs of th e LED d ispl ays, a nd t he sett ing proc edure of th e switc hes .
4 - 6 4 - 6 MELSEC-Q 4 SETUP AND PROCED UR ES BEFOR E OPERATION 4.3.1 Meanings of th e LED di spl ay s The f ollowi ng exp lains the nam es and m eanings of t he LEDs loc ated on t he top surf ace of t he QJ 71DN 91 when t he mod e is set t o 0 t o 8.
4 - 7 4 - 7 MELSEC-Q 4 SETUP AND PROCED UR ES BEFOR E OPERATION 4.3.2 Node number setti ng sw it ch The f ollowi ng exp lai ns the nod e num ber se ttin g s witch of the QJ71 DN91 .
4 - 8 4 - 8 MELSEC-Q 4 SETUP AND PROCED UR ES BEFOR E OPERATION 4.4 Hardw are Test The har dwar e tes t ch eck s whether or not t he sta ndal one m odul e op erates norm all y. It perform s a ROM c heck , RAM chec k, s elf-lo op tes t, etc. Be sur e to p erf orm the har dwar e test bef ore c onfigur in g a s ystem .
4 - 9 4 - 9 MELSEC-Q 4 SETUP AND PROCED UR ES BEFOR E OPERATION 4.5 Connecting the C omm uni cation C abl es to the QJ7 1DN 91 (1) Connecti ng the communi cation cabl es The f ollowi ng exp lains the conn ection m ethod of the comm unica tion cabl es to t he QJ71D N91.
4 - 10 4 - 10 MELSEC-Q 4 SETUP AND PROCED UR ES BEFOR E OPERATION 4.6 Communicati on Test The tra nsm iss ion test and rece ptio n test ar e perf orm ed by c onnec tin g the Q J71D N9 1 and ot her D evic eNet dev ices with a c om munic atio n cab le. T here is n o res tricti on on the nod e num ber s ett ing of the c omm unica tion count erpar t.
4 - 11 4 - 11 MELSEC-Q 4 SETUP AND PROCED UR ES BEFOR E OPERATION 4.7 Instructions for Connecti ng the N etw o rk Power Supply This sect ion ex pla ins th e ins truc tio ns for conn ect ing th e net work power su ppl y.
4 - 12 4 - 12 MELSEC-Q 4 SETUP AND PROCED UR ES BEFOR E OPERATION 4.7.2 Calculati ng netw ork power supply unit installation position and curr ent capacity This sectio n expla ins th e calcu latin g networ k power suppl y unit insta llat ion pos ition an d current capa city .
4 - 13 4 - 13 MELSEC-Q 4 SETUP AND PROCED UR ES BEFOR E OPERATION (3) Remedy f or insufficient netw ork power supply curr ent capacity If the netw ork po wer su ppl y unit is c onnec ted t o a t hick -cab le ne twork , as s ho wn below. Master stat ion 1.
4 - 14 4 - 14 MELSEC-Q 4 SETUP AND PROCED UR ES BEFOR E OPERATION (4) Mix ed tr unk line and dr op l ine The c urrent c ap acit y is c alcu lated as s hown belo w when the net work p ower suppl y unit is c onnec ted to a net work with 200 m of thick -c able tru nk line and 6 m of t hin-cabl e drop li ne.
5 - 1 5 - 1 MELSEC-Q 5 PARAMETER SETTINGS 5 5 PARAMETER SETTINGS This chapt er ex plains th e sett ing item s of the par am eters th at ar e re quire d to r un t he QJ71D N91. The fo ll ow ing t h ree met h od s a re avai la bl e to set th e pa ra met e rs.
5 - 2 5 - 2 MELSEC-Q 5 PARAMETER SETTINGS 5 5.1.2 Parameters for the sl av e function The fo ll owin g e xpla i ns th e sett in g it e ms of th e pa ra met e rs fo r the slav e fu n cti on.
5 - 3 5 - 3 MELSEC-Q 5 PARAMETER SETTINGS 5.3 Setting Us ing the Auto Configuration Function The A uto C onfigur at ion f uncti on a utomat ica lly cr eates par ameter s b y detect ing a sla ve node i n a D evice Net n etwork , which is a s upp lem entar y funct ion f or cre ating param eters.
5 - 4 5 - 4 MELSEC-Q 5 PARAMETER SETTINGS (2) Descripti on of auto con figur ati on setti ng s Table 5.1 lists t he i tems that ar e au tom atical ly det ect ed and s et with th e Au to Configur at ion fu ncti on. To chan ge th e con tents of settin gs, us e th e seq uence progr am .
5 - 5 5 - 5 MELSEC-Q 5 PARAMETER SETTINGS Table 5.1 Items set by auto configuration ( 2/3) Buffe r memory address (hexadecim al) Item Descr iption 0210 H to 0 2 17 H 8th node setting Sam e as the 1st .
5 - 6 5 - 6 MELSEC-Q 5 PARAMETER SETTINGS Table 5.1 Items set by auto configuration ( 3/3) Buffe r memory address (hexadecim al) Item Descr iption 0388 H to 038F H 55th node sett ing Same as the 1st n.
6 - 1 6 - 1 MELSEC-Q 6 UTILITY PAC KAGE ( GX C onfig ur ator -DN) 6 6 UTILITY PACKAGE (GX Configurator-DN) 6.1 Fun ctions of the Utility Packa ge Table 6.
6 - 2 6 - 2 MELSEC-Q 6 UTILITY PAC KAGE ( GX C onfig ur ator -DN) 6 6.2 Installing and Uninstalling the Utility Package See "M etho d of ins talli ng the M ELSOFT Ser ies" attac hed with t he u tilit y pack age regar ding t he i nsta ll an d un insta ll o perat ion f or t he ut ilit y pack age.
6 - 3 6 - 3 MELSEC-Q 6 UTILITY PAC KAGE ( GX C onfig ur ator -DN) (6) About the number o f par ameter s that ca n be set i n GX Configurator -DN The num ber of p aram eters th at ca n be s et b y the .
6 - 4 6 - 4 MELSEC-Q 6 UTILITY PAC KAGE ( GX C onfig ur ator -DN) 6.2.2 Operating env i r onment The op erati ng e nvir onment of t he per son al com puter wher e the GX Config ura tor-DN is used is exp laine d.
6 - 5 6 - 5 MELSEC-Q 6 UTILITY PAC KAGE ( GX C onfig ur ator -DN) 6.3 Explanation of Utility Package Operation 6.3.1 How to perform common utility package operations (1) Avail able contr ol key s Speci al k eys th at can be us ed duri ng oper ation of t he ut ilit y pack age and th eir appl i cat io n s are show n in the ta ble bel ow.
6 - 6 6 - 6 MELSEC-Q 6 UTILITY PAC KAGE ( GX C onfig ur ator -DN) (2) Data to b e created with the utility packa ge The da ta a nd fil es sh own b elow t hat ar e cre ated with the ut ilit y pack age are a lso process ed using GX D eve loper oper ation .
6 - 7 6 - 7 MELSEC-Q 6 UTILITY PAC KAGE ( GX C onfig ur ator -DN) <Flash ROM data> (a) T he data s et with f las h ROM se ttin gs is ca lled th e flas h ROM dat a, wh ich can be sa ved in a des ire d dir ect or y diff erent from the G X De velo per proj ect.
6 - 8 6 - 8 MELSEC-Q 6 UTILITY PAC KAGE ( GX C onfig ur ator -DN) 6.3.2 Overv i ew of operation GX Developer screen [Tools] - [Intelligent function u tility] - [Start] Scr e en fo r intellig ent func tion module parameter setti ng module select Enter "Start I/O No.
6 - 9 6 - 9 MELSEC-Q 6 UTILITY PAC KAGE ( GX C onfig ur ator -DN) [Online] - [Mon itor/test] Select monitor/te st module Monitor/Test screen See Section 6.5. Enter "Start I/O No.," then select "Package name" and "Module model name.
6 - 10 6 - 10 MELSEC-Q 6 UTILITY PAC KAGE ( GX C onfig ur ator -DN) 6.3.3 Starting the in telligent f unctio n modu le utility [Purpose of Setting] By st artin g the intel ligent func tion m odu le uti lit y from the G X D evelo per, d ispla y th e Param eter Setti ng M odule S elec tio n scr een.
6 - 11 6 - 11 MELSEC-Q 6 UTILITY PAC KAGE ( GX C onfig ur ator -DN) (3) Menu bar (a) File items W ith file operat ion , the param eters of the int ell igen t func tion m odul e for the project ope ned with the GX De velo per c an b e mani pul ated. [Open fil e] : Read s th e pa ra mete r file.
6 - 12 6 - 12 MELSEC-Q 6 UTILITY PAC KAGE ( GX C onfig ur ator -DN) 6.4 Auto Refresh Setting s [Purpose of Setting] Set s th e QJ71DN 91 ' s bu ffe r me mory that is au to mat i c al l y refre she d. For t he auto ref resh setti ng it em s, see Secti on 6 .
6 - 13 6 - 13 MELSEC-Q 6 UTILITY PAC KAGE ( GX C onfig ur ator -DN) [Explanati on of items] (1) Descripti on of the screen display Buff er si ze on m odu le s ide : Displa ys the buff er m emor y size of the se ttin g it em . Number of tr ansf er words on modu le s ide : Displ ays th e num ber of words t o be trans ferr ed.
6 - 14 6 - 14 MELSEC-Q 6 UTILITY PAC KAGE ( GX C onfig ur ator -DN) 6.5 Monitor/Test [Purpose of Setting] Buff er m emor y monitor ing/te st ing and I/ O sign al m onitor ing/t est ing ar e star ted from this screen. [Startup procedure] Selec t m onitor/ test modul e scr een " Start I /O No.
6 - 15 6 - 15 MELSEC-Q 6 UTILITY PAC KAGE ( GX C onfig ur ator -DN) 1) Each Node Configurati on Status Monitor Each Node Communication Status Monitor Each Node Communication Error Status Monitor 2 ) E.
6 - 16 6 - 16 MELSEC-Q 6 UTILITY PAC KAGE ( GX C onfig ur ator -DN) 2) Message Communication Area Mon itor/ T est Master Function For IO Address Area M onitor 3 ) Master Function Receive Dat a Monito .
6 - 17 6 - 17 MELSEC-Q 6 UTILITY PAC KAGE ( GX C onfig ur ator -DN) 3) Slave Function Receive Data Monito r Slave Function Transmit Data Monitor/ Test Auto Configuration 4) Master Function Transmit Da.
6 - 18 6 - 18 MELSEC-Q 6 UTILITY PAC KAGE ( GX C onfig ur ator -DN) Parameter Backup 4) Parameters saved i n a file can be edited wi th "Flash ROM setting".
6 - 19 6 - 19 MELSEC-Q 6 UTILITY PAC KAGE ( GX C onfig ur ator -DN) [Explanati on of items] (1) Description of screen di splay Setti ng i te m : Display s the I/O sign al and bu ffe r me mory names. Current value : Monitor s th e I/O s igna l status a nd pres ent b uff er m emory value.
6 - 20 6 - 20 MELSEC-Q 6 UTILITY PAC KAGE ( GX C onfig ur ator -DN) 6.6 Flash ROM Setting s [Purpose of Setting] The c ontents of flash ROM s etti ngs ar e ed ited off line. The ed ited param eters can b e writt en int o the m odule on t he "Par am eter Back up" screen of "Mon itor/T est".
6 - 21 6 - 21 MELSEC-Q 6 UTILITY PAC KAGE ( GX C onfig ur ator -DN) [Explanati on of items] (1) Description of screen di splay Sett ing item : Disp lays th e param eter nam es . Sett ing ( value) : En ter or sel ect t he va lue t o be set in th e flas h RO M.
7 - 1 7 - 1 MELSEC-Q 7 PROGRAMMING W HEN EXECUTING THE MASTE R FUNCTION 7 7 PROGRAMMING WHEN EXECUTING THE MASTE R FUNCTION This chapt er ex plains pro gramm ing when the m aster func tion is ex ecut ed. 7.1 Precautions on Prog ramming This sectio n expla ins the pr ecaut ions whe n creat ing a pr ogram .
7 - 2 7 - 2 MELSEC-Q 7 PROGRAMMING W HEN EXECUTING THE MASTE R FUNCTION 7 7.2 System Config ur ati on The pro gram s ex plains in t his chapt er are bas ed o n the fol lowing s ystem conf igura tion: .
7 - 3 7 - 3 MELSEC-Q 7 PROGRAMMING W HEN EXECUTING THE MASTE R FUNCTION The f ollowi ng sho ws t he re lations hips am ong t he PLC CPU, mas ter nod e buf fer mem or y an d eac h slave nod e. PLC CPU QJ71DN91 master node Remote I/O (Nod e No. 1) 8-point input 700 H X100 to X 107 Node No.
7 - 4 7 - 4 MELSEC-Q 7 PROGRAMMING W HEN EXECUTING THE MASTE R FUNCTION 7.3 Setting Par ameters This sect ion ex pla ins exam pl es of pr ogr am for s etting p aram eters . If GX Confi gurat or-DN is used, th e pro gram s descri bed in Sec tio n 7.3.1 thr ough Secti on 7.
7 - 5 7 - 5 MELSEC-Q 7 PROGRAMMING W HEN EXECUTING THE MASTE R FUNCTION Comm and for se tting the p arame ters for t he master f unction Sets t he node number o f the third slave no de to 4 and the message gro up to 3. Sets th e connecti on type of th e third slave no de to pol ling.
7 - 6 7 - 6 MELSEC-Q 7 PROGRAMMING W HEN EXECUTING THE MASTE R FUNCTION 7.3.2 Creating par ameter s using auto conf igur ation The f ollowi ng ex plai ns a m etho d for crea ting param eter s us ing auto c onfi gurat ion.
7 - 7 7 - 7 MELSEC-Q 7 PROGRAMMING W HEN EXECUTING THE MASTE R FUNCTION 7.4 I/O Communication w ith Slave Nodes This sect ion ex pla ins an exam ple of a s eque nce progr am tha t per form s I/O communi cation. If GX Configur at or-DN is us ed, the F ROM an d TO instr ucti ons ar e not r eq uired.
7 - 8 7 - 8 MELSEC-Q 7 PROGRAMMING W HEN EXECUTING THE MASTE R FUNCTION 7.5 Performing Message Communication This sect ion ex pla ins an exam ple of a s eq uence progr am that perfor ms mes sage communi cation.
7 - 9 7 - 9 MELSEC-Q 7 PROGRAMMING W HEN EXECUTING THE MASTE R FUNCTION 7.5.2 Example o f messag e commu nication write The f ollowi ng sho ws a n exam ple of a sequ ence progr am that writes attri butes to n ode number 3.
7 - 10 7 - 10 MELSEC-Q 7 PROGRAMMING W HEN EXECUTING THE MASTE R FUNCTION 7.6 O btain ing Erro r Inf orm ation This sect ion ex pla ins an exam ple of a s eque nce progr am tha t obt ains the error inform ation f or the m aster funct ion . Err or reset Reads the error cod e from t he buf fer memory .
7 - 11 7 - 11 MELSEC-Q 7 PROGRAMMING W HEN EXECUTING THE MASTE R FUNCTION 7.7 Allocating Transmissi on/R eception D ata Storag e Devices for Future Expansion If the tr ansm is sion/rec ept ion da ta o.
7 - 12 7 - 12 MELSEC-Q 7 PROGRAMMING W HEN EXECUTING THE MASTE R FUNCTION The f ollow ing ex plai ns an exam ple of t he seq uenc e pr ogram us ed in t his c ase. Parameter setting program (See Section 7.3.) Star ts I/O comm u n i c ation. Reads th e I/ O ad dres s area infor matio n.
8 - 1 8 - 1 MELSEC-Q 8 PROGRAMMING W HEN EXECUTING THE SLAVE FUNCTION 8 8 PROGRAMMING WHEN EXECUTING THE SLAVE FUNCTION This chapt er ex plains pro gramm ing when the s lave f unc tion is exec ute d.
8 - 2 8 - 2 MELSEC-Q 8 PROGRAMMING W HEN EXECUTING THE SLAVE FUNCTION 8 8.2 Setting Par ameters Us i ng the Seq uence Pr og r am This sect ion ex pla ins an ex ample of a s eq uence pro gram for s ettin g par am eters.
8 - 3 8 - 3 MELSEC-Q 8 PROGRAMMING W HEN EXECUTING THE SLAVE FUNCTION 8.3 I/O Communication with the M aster Node This sect ion ex pla ins an exam ple of a s eque nce progr am tha t per form s I/O communi ca ti on wi th th e mast e r no de .
8 - 4 8 - 4 MELSEC-Q 8 PROGRAMMING W HEN EXECUTING THE SLAVE FUNCTION 8.4 O btain ing Erro r Inf orm ation This sect ion ex pla ins an exam ple of a s eque nce progr am tha t obt ains the error inform ati on for the s lave f unct ion. Error r eset Error ha ndlin g program Reads the e rror co de from the buffer memory .
9 - 1 9 - 1 MELSEC-Q 9 TROUBLESHOOTING 9 9 TROUBLESHOOTING This chapt er ex plains the c ont ents of err ors t hat m a y occur while using the Q J71D N91 as wel l as t heir tr oub lesho oting pr oce dures . This chapt er co nsists of the f ollo wing two s ecti ons: Secti on 9.
9 - 2 9 - 2 MELSEC-Q 9 TROUBLESHOOTING 9 9.1 Items to Check W hen an Error Occur s This sect ion ex pla ins th e it em s to check when a n err or occ urs a nd its tr oubles hoot ing proce dure: 9.
9 - 3 9 - 3 MELSEC-Q 9 TROUBLESHOOTING 9.1.2 When communication w ith all slave nodes cannot be per f ormed (usi ng the master function) Communic a tion wit h all slave nodes cannot be performe d (the.
9 - 4 9 - 4 MELSEC-Q 9 TROUBLESHOOTING 9.1.3 When communication w ith a specific slave node cannot be p er for med ( using the master function) Commu nication with a speci fic slave node cannot b e pe.
9 - 5 9 - 5 MELSEC-Q 9 TROUBLESHOOTING 9.1.4 When communication w ith the master node cannot be per formed (using the slav e function) Communication with the master node cannot be performed (when the .
9 - 6 9 - 6 MELSEC-Q 9 TROUBLESHOOTING 9.2 Error C odes This sect ion ex pla ins th e cont ents of err or co des and ac tio ns to be tak en. Error c odes are c lass ifie d int o th e comm unic atio n err or co des a nd th e exec uti on err or codes duri ng m ess age com m unicatio n.
9 - 7 9 - 7 MELSEC-Q 9 TROUBLESHOOTING Detection time period Error code (HEX. ) Error de te ct i on Descrip tion Corre c tiv e ac tion Mast er functi on Slave functi on 07 H QJ71 DN91 No slav e nod e has been set . • Set at least on e s la ve node .
9 - 8 9 - 8 MELSEC-Q 9 TROUBLESHOOTING (3) wh en th e err or-d etected no de n umber (lo wer b yte of error inf orm ation) is oth er than FF H and FE H Detection time period Error code (HEX.
9 - 9 9 - 9 MELSEC-Q 9 TROUBLESHOOTING 9.2.2 Execution er r or codes of messag e commu ni cation ( usi ng the master function onl y ) The ex ecut ion error c odes ar e stor ed in buff er m emor y addr ess 0121 H .
9 - 10 9 - 10 MELSEC-Q 9 TROUBLESHOOTING Error code (Dec. ) Error detecti on Descr ip t ion Corre c tiv e ac tion 19 Slave no de Suf fi c ient dat a to ex ecut e th e sp ec i fie d o pera t ion wa s no t provi ded. • Check that the sp ecifie d MAC ID, cla ss ID, instan ce ID and attr ib ut e I D are co rre c t.
9 - 11 9 - 11 MELSEC-Q 9 TROUBLESHOOTING 9.3 Verifying the QJ71DN91 Status on the GX Dev el oper Sy stem M onitor W hen the QJ71DN9 1 deta iled inf orm ation is selec ted on th e GX Deve loper system monitor , t he err or c odes and L ED i llum inat ion st atus ca n be v erifi ed.
9 - 12 9 - 12 MELSEC-Q 9 TROUBLESHOOTING (c) H/W LED Inform ation Displ ays th e LED illum inati on stat us of the Q J71DN 91. (0 : of f, 1: on) ERR: Indica tes the " ERR" LED on s tatus. MS RE D: In di cat e s the "MS red" LED on statu s.
App - 1 Ap p - 1 MELSEC-Q APPENDIX App. APPENDIX Appendix 1 Ex ternal Dimension Diagr am The f ollowi ng f igure s hows an exter nal dim ens ion d iagr am of the Q J71D N91: QJ71DN91 RUN MS NS ERR.
App - 2 Ap p - 2 MELSEC-Q APPENDIX App. Appendix 2 D i fferences betw een the QJ71D N 91 and t he AJ71D N 91/A1SJ 71D N 91 The fo ll ow ing t abl e list s th e di ffe re n c es be twe en th e QJ7 1DN9.
App - 3 Ap p - 3 MELSEC-Q APPENDIX Appendix 3 Par ameter Setting Sheet (For the Master Function) Ite m Set ting range Bu f f e r me mo ry addres s Remark Setting value Cons ta nt scan 0 ms to 655 35 ms 01D7 H Setting to make the li nk sc an tim e co nstant.
App - 4 Ap p - 4 MELSEC-Q APPENDIX Appendix 4 Par ameter Setting Sheet (For the Slav e Functi on) Ite m Setti ng range Bu f fer m e mory addres s Remark Setting val ue Settin g ar ea f or t he numbe r of slav e functi on inp ut poi nts 0 to 128 by tes 060 E H S e t s the I /O data rec ep t io n s ize fo r th e s lave fun c t ion par a mete rs .
App - 5 Ap p - 5 MELSEC-Q APPENDIX Appendix 5 Li st of Communi cati on Par a meter s o f Slav e Nodes Manufactured by Var i ous Manufacturers The fol lowing table l ists an exam pl e of param eter set ting va lues in order to comm unicate wit h sla ve n odes m anuf actur ed b y vari ous m anuf actur ers.
App - 6 Ap p - 6 MELSEC-Q APPENDIX Appendix 6 ED S Fi le of the QJ71DN91 The f ollowi ng s hows t he E DS f ile of the QJ 71D N91. T he E DS f ile is st ored in t he CD- ROM of GX Co nfig urator -DN.
App - 7 Ap p - 7 MELSEC-Q APPENDIX MEM O.
Index - 1 I ndex - 1 Ind. INDEX [A] Auto c onfigur at ion com plet ion ...................... 3- 23 Auto c omm unicat ion s tart s etti ng.................. 3- 46 Auto c onfigur at ion ex ecuti ng......................... 3-23 Auto c onfi gurat ion operat ion s etting .
Index - 2 I ndex - 2 Ind. [M] Model nam e disp la y ...................................... 3-44 Module read y ................................................. 3-22 [N] Node num ber ................................................. 3-44 [O] Obtainin g e rror info rmati on (m aster f unction) .
WARRANT Y Please confirm the follow ing product w arranty details before starting use. 1. Gratis W arranty Term and Grati s W arranty Rang e If any faults or defects (hereinafter "Fail ure").
Micr osoft, W indows, W indows NT are r egist ered trad emar ks of Micr osoft C orp orati on in t he U nite d St ates and oth er co untri es. Pent ium is a re gis tered tradem ar k of Intel Corpor atio n in t he U nite d St ates a nd o ther coun tries .
INDUSTRIAL AUTOMATION MI T SU BI S HI ELE C TRI C MIT SU BI S HI ELE C TRI C Gothaer Strasse 8 Phone: +49 2102 486-0 Fax: +49 2102 486-7170 www.mitsubishi-automation.de D-40880 Ratingen Hotline: +49 1805 000-765 megfa-mail@meg.mee.com www.mitsubishi-automation.
Een belangrijk punt na aankoop van elk apparaat Mitsubishi Electronics QJ71DN91 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Mitsubishi Electronics QJ71DN91 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Mitsubishi Electronics QJ71DN91 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Mitsubishi Electronics QJ71DN91 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Mitsubishi Electronics QJ71DN91 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Mitsubishi Electronics QJ71DN91 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Mitsubishi Electronics QJ71DN91 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Mitsubishi Electronics QJ71DN91 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.