Installation Instructions and Homeowner ’ s Manual 20012253 10/09 Rev . 7 Builder Direct V ent Models: 36CDVXRRN (Rear V ent) 36CDVXTRN (T op V ent) DO NOT ST ORE OR USE GASOLINE OR OTHER FLAMMABLE V APORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
2 CDVX Series Direct Vent Gas Fireplace 20012253 PLEASE READ THE INST ALLA TION & OPERA TING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a MHSC fireplace. IMPORT ANT : Read all instructions and warnings carefully before starting installation.
3 CDVX Series Direct Vent Gas Fireplace 20012253 This gas appliance should be installed by a qualified installer , preferably NFI or WETT (Canada) certified, in accordance with local building codes and with current CSA-B149.1 Installation codes for Gas Burning Appliances and Equipment.
4 CDVX Series Direct Vent Gas Fireplace 20012253 Requirements for the Commonwealth of Massachusetts All gas fitting and installation of this heater shall only be done by a licensed gas fitter or licensed plumber .
5 CDVX Series Direct Vent Gas Fireplace 20012253 7 6 ” (187 mm) 16 6 ” (422 mm) 36 56M ” (921 mm) Minimum Rough Opening Width Minimum Rough Opening Height Minimum Rough Opening Dep.
6 CDVX Series Direct Vent Gas Fireplace 20012253 7 6 ” (187 mm) 16 6 ” (422 mm) 36 56M ” (921 mm) Minimum Rough Opening Width Minimum Rough Opening Height Minimum Rough Opening Depth.
7 CDVX Series Direct Vent Gas Fireplace 20012253 T op of Unit to Ceiling ............................... 36” (914 mm) Front of Unit to Combustibles .................. 36” (914 mm) Appliance T op ....................................................
8 CDVX Series Direct Vent Gas Fireplace 20012253 A hearth is not mandatory but is recommended for aesthetic purposes. We recommend a noncombustible hearth which projects out 12” (305 mm) or more from the front of the fireplace.
9 CDVX Series Direct Vent Gas Fireplace 20012253 Gas Specifications Max. Min. Inp ut Input Mo del Fuel Gas Control BTU/h BTU/h 36CD VXRRN Nat Milli volt 21, 000 14,700 36CDVXRR P* Prop Millivolt 21,0 0 0 1 5,750 36CDVXTRN Nat Millivolt 21,000 14,700 36CDVXTRP* Prop Millivolt 21,000 15,750 *Using conversion kit Installation 1.
10 CDVX Series Direct Vent Gas Fireplace 20012253 The fireplace, when installed, must be electrically connected and grounded in accordance with local codes or , in the ab- sence of local codes, with the current CSA C22.1 Canadian Electrical Code. For USA installations follow local codes and the national electrical code ANSI/ NFP A No.
1 1 CDVX Series Direct Vent Gas Fireplace 20012253 V V V V V V V X X X D E B B B C B M B A J K F L VENT TERMINA TION AIR SUPPL Y INLET AREA WHERE TERMINAL IS NOT PERMITTED H I Ýi` Ãi` Operable Operable Fixed Closed V B CFM145a DV T ermin Location 5/01/01 Rev .
12 CDVX Series Direct Vent Gas Fireplace 20012253 General Information Assembling V ent Pipes Canadian Installations: V enting system must be installed in accordance with the current CSA-B149.1 installation code. USA Installations: The venting system must conform with local codes and/ or the current National Fuel Gas code ANSI Z223.
13 CDVX Series Direct Vent Gas Fireplace 20012253 The vent chart should be read in conjunction with the following vent installation instructions to determine the relationship of the vertical and horizontal dimensions of the vent system. 1. Determine the height of the center of the horizontal vent pipe exiting through the outer wall.
14 CDVX Series Direct Vent Gas Fireplace 20012253 • Minimum clearances between vent pipe and com- bustible materials are as follows: T op - 1” (25 mm) Sides - 1” (25 mm) Bottom - 1” (25 mm) .
15 CDVX Series Direct Vent Gas Fireplace 20012253 FP1005 Side View V ent T ermination 1/25/00 djt 22” (559 mm) C L Finished W all Secure with Screw V ent T ermination Firestop FP1005a Fig.
16 CDVX Series Direct Vent Gas Fireplace 20012253 &0 REARFLEXV ENT Fig. 21 Bend flex pipe up 90° as close to fireplace as pos- sible. FP1604 &0 REARVIEWFLEXVEN T Do Not Exceed 45° Bend Corner Framing T ermination FP1606 Fig.
17 CDVX Series Direct Vent Gas Fireplace 20012253 needs to have an immediate rise before going hori- zontal. NOTE: Be careful not to distort the outer flex as this will affect the performance of the fireplace. 6. Secure the collar to the firestop by bending the tab out on the firestop and running a screw through the tab and collar .
18 CDVX Series Direct Vent Gas Fireplace 20012253 1 2 3 4 1 + 2 + 3 + 4 = 270 o CFM132 Insert Rear V ent Sidewall 2/26/01 sta CFM132 Fig. 29 Maximum number of elbows.
19 CDVX Series Direct Vent Gas Fireplace 20012253 STEP 6 Support the horizontal pipes every 36” (914 mm) with metal pipe straps. Make sure that the horizontal vent pipe is installed on a level horizontal plane. STEP 7 Re-check the fireplace to make sure that it is levelled, properly positioned, and nailed or screwed to the floor .
20 CDVX Series Direct Vent Gas Fireplace 20012253 Do not back fill around snorkel. A clearance of at least 4” (102 mm) must be maintained between the snorkel and the soil. BG401 Snorkel 2/10/99 djt Foundation Recess Snorkel W all Screws Recess Brackets W atertight Seal Around Pipe Sheet Metal Screws BG401 Fig.
21 CDVX Series Direct Vent Gas Fireplace 20012253 CFM100 Firestop-V ertical 09/20/00 1 1" 1 1" Joist Joist Firestop Spacer Nails (4) Upper Floor Attic Insulation Shield Ceiling Installation CFM100 Fig. 38 Place firestop spacer(s) and secure.
22 CDVX Series Direct Vent Gas Fireplace 20012253 How to Use the V ent Graph The vent chart should be read in conjunction with the following vent installation instructions to determine the relationship of the vertical and horizontal dimensions of the vent system.
23 CDVX Series Direct Vent Gas Fireplace 20012253 Since it is very important that the vent- ing system maintain its balance between the combustion air intake and the flue gas exhaust, certain limitations as to vent configurations apply and must be strictly adhered to.
24 CDVX Series Direct Vent Gas Fireplace 20012253 1 2 3 4 Example: Elbow 1 = 90° Elbow 2 = 45° Elbow 3 = 45° Elbow 4 = 90° T otal angular variation = 270° 1 + 2 + 3 + 4 = 270° FP1239 Fig. 48 Maximum number of elbow degrees. STEP 2 Place fireplace into position.
25 CDVX Series Direct Vent Gas Fireplace 20012253 FP1242 Fig. 51 Through the wall. FP1243 Fig. 52 Apply high temperature sealant to collars or termina- tions. Below Grade Installations When it is not possible to meet the required vent ter- minal clearances of 12” (305 mm) above grade level a snorkel vent kit is recommended.
26 CDVX Series Direct Vent Gas Fireplace 20012253 BG402a T op V ent Below grade installation 1/26/00 djt Firestop 7” Pipe 7TDVSNORK (Snorkel) 4” (102mm) Clearance Min.
27 CDVX Series Direct Vent Gas Fireplace 20012253 1 2 3 4 Max. 8' (2.4m) FP1245 through the roof 90 & 45 degree 12/02 1 + 2 + 3 + 4 = 270° FP1245 Fig.
28 CDVX Series Direct Vent Gas Fireplace 20012253 V enting Components 584G V enting Components Firestop spacer 2/25/99 djt 584H V enting components attic insulation shield 2/25/99 djt 584I vent compon.
29 CDVX Series Direct Vent Gas Fireplace 20012253 Only glass approved by MHSC should be used on this fireplace. The top louvre panel is removed by lifting the panel vertically and pulling it away from the appliance. (Fig. 61) The lower access door is removed in the same manner .
30 CDVX Series Direct Vent Gas Fireplace 20012253 , ' #$68LOGS Logs The 36CDVX logs are shipped in place. If a log is broken, refer to the replacement parts list for a replace- ment. Figure 63 shows where the logs are secured to the fireplace.
31 CDVX Series Direct Vent Gas Fireplace 20012253 3. Open control access panel. 4. Push in gas control knob slightly and turn clock- wise to “OFF”. Do not force. 5. Close control access panel. 1. ST OP! Read the safety information above. 2. T urn off all electrical power to the fireplace.
32 CDVX Series Direct Vent Gas Fireplace 20012253 Lighting and Operating Instructions For Fireplaces equipped with SIT822 Gas V alve (EN or EP) A. This fireplace is equipped with an ignition device which automatically lights the pilot. DO NOT try to light the pilot by hand.
33 CDVX Series Direct Vent Gas Fireplace 20012253 W ARNING: BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE GLASS FRONT . SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION 1. Spark ignitor will not light A. Defective or misaligned Using a match, light pilot.
34 CDVX Series Direct Vent Gas Fireplace 20012253 The conversion of this appliance from one gas to another must be carried out by an authorized service provider . 1. Disconnect power to the unit and shut of f the gas sup- ply . 2. Remove window frame assembly .
35 CDVX Series Direct Vent Gas Fireplace 20012253 Fig. 74 Nova SIT820 Gas V alve. D E F FC108 SIT regulator conversion 10/03 O F F P I L O T O FC107 SIT820 valve conversion 10/03 A B C O F F P I L O T O FC107/108 V alve Regulator Conversion SIT 820 NOV A Gas Control V alve (Fig.
36 CDVX Series Direct Vent Gas Fireplace 20012253 Burner and Burner Compartment It is important to keep the burner and the burner compartment clean. At least once per year the logs and lava rock/ember material should be removed and the burner compartment vacuumed and wiped out.
37 CDVX Series Direct Vent Gas Fireplace 20012253 MHSC reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. CDVX 16 14a,b 13 20 2 6a,b 7 10 1 1 12 15 17 21 22 23 3 8 19 1a 1b 18 12253 CDVX parts 2/07 26 25 Ref.
38 CDVX Series Direct Vent Gas Fireplace 20012253 CDVX (continued) 15. Flexible Gas Line w/ON/Off Shut-Of f V alve 20002500 16. Fan Assy (FK12 Option) ZA1 1 10 17. Electrical Cord (6 ft.) 51865 18. Door Assy 20010207 19. Frame Window 20010320 20. Clamp Frame Window 10000949 21.
39 CDVX Series Direct Vent Gas Fireplace 20012253 FK12 This auxiliary fan system increases the efficiency of the circulation of the heating air . The FK12 Fan Assembly is a fixed speed fan system and does not allow for variable speed control. Specifications 1 15 V olts / 60 Hz / 56 W atts.
40 CDVX Series Direct Vent Gas Fireplace 20012253.
41 CDVX Series Direct Vent Gas Fireplace 20012253.
42 CDVX Series Direct Vent Gas Fireplace 20012253.
43 CDVX Series Direct Vent Gas Fireplace 20012253 Lifetime W arranty The following components are warranted for life to the original owner , subject to proof of purchase: Firebox, Combus- tion Chamber , Heat Exchanger , Grate and Stainless Steel Burners.
Efficiency Ratings Model EnerGuide Ratings Steady State (%) D.O.E. Fireplace Efficiency (%) Fan-OFF Fan-ON (AFUE%) 36CDVXRRN 66.9 76 76.5 63 36CDVXRRP 66.9 77 78 63 36CDVXTRN 57 76 76.5 63 36CDVXTRP 57 77 78 63 MHSC 149 Cleveland Drive • Paris, Kentucky 40361 www .
Een belangrijk punt na aankoop van elk apparaat Monessen Hearth 36CDVXTRN (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Monessen Hearth 36CDVXTRN heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Monessen Hearth 36CDVXTRN vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Monessen Hearth 36CDVXTRN leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Monessen Hearth 36CDVXTRN krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Monessen Hearth 36CDVXTRN bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Monessen Hearth 36CDVXTRN kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Monessen Hearth 36CDVXTRN . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.