Gebruiksaanwijzing /service van het product Industio CP-114 Series CP-114 Series van de fabrikant Moxa Technologies
Ga naar pagina of 55
Industio CP-114 Series User ’ s Manual 3 in 1 RS-232/422/485 Industrial Serial Board for PCI Bus Fourth Edition, November 2004 www.moxa.com/product Moxa Technologies Co., Ltd. Tel: +886-2-8919-1230 Fax: +886-2-8919-1231 Web: www.moxa.com MOXA Technical Support Worldwide: support@moxa.
Industio CP-114 Series User’s Manual The product described in this manual is furnished under a license agreement and may be used only in accordance with the terms of the agreements. Copyright Notice Copyright 2004, Moxa Technologies Co., Ltd. All rights reserved.
MOXA Internet Services Customer satisfaction is our number one concern, and to ensure that customers receive the full benefit of our products, Moxa Internet Services has been set up to provide technical support, driver updates, product information, and user’s manual updates.
About This Manual This manual is composed of six chapters and one appendix. Th is manual is written for installer, system administrator and software programmer. If you are a first-time installer and system administrato r, we recommend you to go through the whole manual except Chapter 4.
Table of Contents Chapter 1 Introduction ............................................................................................. 1-1 Overview ................................................................................................ 1-1 Features .
.
Industio CP-114 User's Manual 1-1 1 1 1 Introduction Overview Industio - Industrial Multiport Async Solutions for PCI The term Industio stands for smart multiport serial I/O solution for industrial applications.
1-2 Industio CP-114 User's Manual Operating System Support Support for Windows NT, Windows 95/98 and DOS with user-friendly installation, configuration and performance. MOXA Serial Comm Tools For application development, MOXA provides an easy-to-use serial communication library under Windows NT, Windows 95/98 ( PComm ) and DOS ( API-232 ).
Introduction Industio CP-114 User's Manual 1-3 Check List Upon unpacking the Industio CP-114 Series, you should find items in the package: " Industio CP-114 Series 4 ports serial board × 1 .
1-4 Industio CP-114 User's Manual.
Industio CP-114 User's Manual 2-1 2 2 2 Hardware Installation The installation of the Industio CP-114 Series consists of hardware and software installation. The respective sections of the operating systems in the next chapter deal with the software installation.
2-2 Industio CP-114 User's Manual ! S2 Data Mode Selection Switch for Port 1/2/3/4: (Valid if JP5/6 is Left and S1 is ON) ON* Set the RS-485 port to Automatic Data Direction Control Mode.
Industio CP-114 User's Manual 3-1 3 3 3 Software Installation In this chapter, the software driver installation, configuration and driver update/removal procedures are described for various operating systems, including Windows NT, Windows 95/98 and DOS.
3-2 Industio CP-114 User's Manual 5. Select “MOXA Smartio/Industio Family multiport board” in the “Select OEM Option” dialog box, and click [OK] to enter the “Moxa Sm artio/Industio Configuration Panel” dialog box to start the installation.
Software Installation Industio CP-114 User's Manual 3-3 6. In the “ Moxa Smartio/Industio Configuration Panel ” dialog box, click [ Add ] to enter “ Property ” dialog box to add the Industio CP-114 Series board. Select the “ CP-114 Series ” in the “Board Type” field.
3-4 Industio CP-114 User's Manual Rx FIFO trigger levels, at 1, 4, 8 or 14 bytes, are available, and the default value is 14 bytes. ! Tx FIFO Size Tx FIFO sizes from 1 to 16 bytes are available, and the default value is 16 bytes.
Software Installation Industio CP-114 User's Manual 3-5 Note ! Once the board and the driver are installed and the driver restarts successfully, you can start to develop applications with the PComm library (See “Serial Programming Tools”) or the Microsoft Win32 API.
3-6 Industio CP-114 User's Manual Removing Driver To remove the driver for the Industio CP-114 board, 1. Open the [ Control Panel ], click on the [ Network ] icon, and select the [ Adapters ] tab.
Software Installation Industio CP-114 User's Manual 3-7 The following flow chart illustrates the driver installation stages of the Industio CP-114 Series boards.
Industio CP-114 User's Manual 3-8.
Software Installation Industio CP-114 User's Manual 3-9 Windows 95 Windows 98 2. Click on the [Other Locations] button. 2. Select “Display a list...” and click [Next>]. 3. Type “ A:Windows.95 ” in the Location field, and click [OK] button.
3-10 Industio CP-114 User's Manual 5. Type “A:Windows.95” and click [ OK ] button. The system will start reading the files from the diskette. 6. Click [Next>] button. 7. Click [Next>] button. Port Configuration Stage This stage displays the “CP-114 Series Installation” dialog box for the port configuration.
Software Installation Industio CP-114 User's Manual 3-11 In the “ CP-114 Series Installation ” dialog box, select the desired port in the port list and click [ Port Setting ] to enter the individual “ Port # ” setting dialog box to change the port number mappings or FIFO settings.
3-12 Industio CP-114 User's Manual Board and Port Ready Stage Click [ OK ] for all the dialog boxes to finish the configuration and exit the “ CP-114 Series Installation ” dialog box. In this last stage, you will complete the driver installation.
Software Installation Industio CP-114 User's Manual 3-13 Configuring Board and Port If you already have installed the driver and want to re-configure the COM number for the ports under Windows 95/98, follow this procedure.
3-14 Industio CP-114 User's Manual Updating Driver This section explains how to update the driver. 1. In the [ Control Panel ], click on the [ System ] icon, select the [ Device Manager ] tab and select [ MOXA Smartio/Industio multiport board ]. 2.
Software Installation Industio CP-114 User's Manual 3-15 Removing Driver This section explains how to remove the Industio CP-114 Series board driver. 1. Open [Control Panel] icon, double click [Add/Remove Programs] icon, and then select [Install/Uninstall] tab.
Industio CP-114 User's Manual 3-16 DOS MOXA DOS API-232 is a software package that assi sts users to develop and/or debug programs for serial communications. This section will show you how to install the package, how to setup up the driver, and how to load or unload driver.
Software Installation Industio CP-114 User's Manual 3-17 Driver Setup The following are steps for setting up the Industio CP-114 Series driver. Note that it is not intended to illustrate all the convenient functions of the setup programs when configuring the boards.
3-18 Industio CP-114 User's Manual Note ! Up to now you have completed the setup for Industio CP-114 Series board. You may skip this step and go directly to the next step 5 if you need not change any setting or configure any board. 3. 3. You may now enter/modify each port’s configurati on.
Software Installation Industio CP-114 User's Manual 3-19 refer to the port by its port number (ID). Duplicated port number is not allowed. That is, each MOXA serial port is referred to as port number in terms of serial programming.
3-20 Industio CP-114 User's Manual Loading Driver Having completed the setup, you can load the driver, "BINDP-DRV.EXE" , at the DOS prompt. The driver will detect the Industio CP-114 Seri es board automatically. If the board(s) is(are) detected, a message similar to below will show: Smartio/Industio Family DOS driver Version 1.
Industio CP-114 User's Manual 4-1 4 4 4 Serial Programming Tools Moxa supports some easy but powerful serial programming libraries and communication troubleshooting utilities under Windows NT and Windows 95/98. You will save a lot of developing time with the MOXA Serial Programming Tools.
4-2 Industio CP-114 User's Manual Utilities Following are short descriptions of each utility. For details, please see the on-line help on the diskette. Diagnostic (for MOXA boards only) A convenient diagnostic program that provides internal and external testing, such as IRQ, TxD/RxD, UART, CTS/RTS, DTR/DSR, DTR/DCD testing, et c.
Serial Programming Tools Industio CP-114 User's Manual 4-3 Monitor (for MOXA boards under Windows NT Only) A useful port status monitoring program that a llows you to watch the selected MOXA COM ports’ data transmitting/receiving throughput and communication line status which are updated and displayed on the screen at time intervals.
4-4 Industio CP-114 User's Manual Terminal Emulator The Terminal Emulator features multi-windows and supports terminal types of VT100 and ANSI. You can transfer data interactively, send pattern periodically or transfer file using ASCII, XMODEM, YMODEM, ZMODEM and KERMIT protocols.
Serial Programming Tools Industio CP-114 User's Manual 4-5 DOS Installing API-232 API-232 Library is the professional serial programming tool for DOS. It is installed automatically along with the MOXA DOS drivers. The installation is detailed in Chapter "Software Installation".
4-6 Industio CP-114 User's Manual Data Scope The Data Scope, BINSCOPE.EXE , is a suite of utility programs that can help users with system troubleshooting and serial communication debugging. There are three major functions in Data Scope utility: 1.
Serial Programming Tools Industio CP-114 User's Manual 4-7 RS-485 Programming If you intend to do RS-485 communication with Indus tio CP-114 Series, please follow the RS-485 programming guide below and also refer to the chapter, “ Connection Cable and Cable Wiring” , for more RS-485 operation details.
4-8 Industio CP-114 User's Manual There are 2 solutions to control RS-485 2-wire transmission. Solution 1 The following model is common in RS-485 2-wire transmission. sio_SetWriteTimeouts(port, 0); /* Set sio_write() into block mode if for Windows NT and Windows 95/98 */ sio_RTS(port, 1); /* Turn on RTS signal.
Industio CP-114 User's Manual 5-1 5 5 5 Connection Cable and Cable Wiring In serial data communications, the term DTE is for Data Terminal Equipment, like PC COM1/2, serial printers and terminals. The term DCE is for Data Communication Equipment, like modems.
5-2 Industio CP-114 User's Manual Type 1: To connect the Industio CP-114 Series to a DTE device. PC CO M2 po rt, Ser ial Pr inter , Terminal, or any DT E Device CP-114 CP-114 DTE Device DB9 Male .
Connection Cable and Cable Wiring Industio CP-114 User's Manual 5-3 Type 2: To connect Industio CP-114 Series to a DCE device. Modem or any DCE Device CP-114 CP-114 DCE Device DB9 Male DB25 Femal.
5-4 Industio CP-114 User's Manual RS-422 Cable Wiring The RS-422 standard uses a balanced voltage digital interface to allow 9600 bps communication over cables of up to 400 ft (1.2 km) in length. Ten receivers can be connected to any one driver for broadcasting systems.
Connection Cable and Cable Wiring Industio CP-114 User's Manual 5-5 RS-485 Cable Wiring The RS-485 standard is an enhanced version of the RS-422 balanced line standard. It allows multiple drivers and receivers in a multidrop systems. As many as 32 drivers and 32 receivers can be put on any multidrop system.
5-6 Industio CP-114 User's Manual Impedance Matching and Termination Resistors For RS-422/485 serial communications, when an electrical signal travels through two different resistance junctions in a transmission line, the impedance mismatch will sometimes cause signal reflection.
Connection Cable and Cable Wiring Industio CP-114 User's Manual 5-7 DB37 Connector The following lists the pin assignments of the Industio CP-114 Series DB37 connector on the bracket. With this information, you may fabricate a ny type of fan-out cables, such as DB37 to DB9 x 4 or DB37 to DB25 x 4.
.
Industio CP-114 User's Manual 6-1 6 6 6 Troubleshooting Common Industio CP-114 Series problems and possible solutions are listed below. If you still have problems, contact your dealer or Moxa for help. Or use the “Problem Report Form” at the end of this manual to report problems to your dealer at once for faster technical support.
6-2 Industio CP-114 User's Manual This indicates that the MOXA board is found, but the IRQ is conflicting with another adapter. Please make sure there is no conflict with other adapter’s IRQ. Check the PCI BIOS IRQ settings first. Make sure that an IRQ is available.
Industio CP-114 User's Manual A-1 A A A Technical Reference Specification " Bus interface: 32-bit PCI (Spec 2.1) " Number of ports: 2 (RS-232 or RS-422/485), 2 (RS-422/485) " I/O address: Assigned by BIOS " IRQ: Assigned by BIOS " Data bits: 5, 6, 7, 8 " Stop bits: 1, 1.
A-2 Industio CP-114 User's Manual The UART chip, 16C550C , is an intelligent asynchronous controller capable of supporting one full duplex channel that simultaneously transfers data at 921.
Problem Report Form Industio CP-114 Series Customer name: Company: Tel: Fax: Email: Date: 1. Moxa Product : CP-114 Series Model : $ CP-114 $ CP-114I $ CP-114S $ CP-114IS Serial Number : ________________ 2. Moxa Driver Version : ________________ 3. Moxa Hardware Settings : PCI slot number ________________________ 4.
Return Procedure For product repair, exchange or refund, you must: " Provide evidence of original purchase. " Fill out the Problem Report Form (PRF) as detailed as possible for shorter product repair time. " Obtain a Return Merchandise Authorization (RMA) number from the sales representative or dealer.
Revision History Document Edition Revision Date Revision Details 3 rd January 27, 2004 1. Update the edition of this manual on the title page. 2. p. 5-5: Changed RS-422 Broadcasting figure. 4 th November 8, 2004 1. Updated Moxa logo. 2. Corrected errors in Chap.
Een belangrijk punt na aankoop van elk apparaat Moxa Technologies Industio CP-114 Series CP-114 Series (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Moxa Technologies Industio CP-114 Series CP-114 Series heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Moxa Technologies Industio CP-114 Series CP-114 Series vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Moxa Technologies Industio CP-114 Series CP-114 Series leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Moxa Technologies Industio CP-114 Series CP-114 Series krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Moxa Technologies Industio CP-114 Series CP-114 Series bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Moxa Technologies Industio CP-114 Series CP-114 Series kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Moxa Technologies Industio CP-114 Series CP-114 Series . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.