© Copyright, 2003, all rights reserved • Securitron Magnalock Corp., 550 Vista Blvd., Sparks NV 89434, USA Tel: (775) 355-5625 • (800) MAGLOCK • Fax: (775) 355-5636 • Website: www.securitron.com An ASSA ABLOY Group company PN# 500-10420 Rev. A.
Rev. A.5, 8/03 SECTION 3. ELECTRICAL INSTALLATION -----------------------------------------------Page 14 SECTION 3.1 GENERAL ELECTRICAL CHARACTERISTICS -----------------------Page 14 This section explains technically the Magnalock's electrical characteristics as a load and is for reference.
Rev. A.5, 8/03 Use of the Magnalock (or any lock) can lead to an unsafe condition within the building if it is controlled in a manner that improperly restricts passage through certain doors. The most important area of concern is to insure that building evacuation is not impeded in the event of a fire or other emergency condition.
Rev. A.5, 8/03 Page- 1 SECURITRON 32, 34, 62 AND 82 SERIES MAGNALOCK INSTALLATION INSTRUCTIONS 1. DESCRIPTION Securitron’s Magnalock family repres ents the state of the art in electric locking. Three different size models are available: The Model 32 and Model 34 series with a holding force of 600 lbs.
Rev. A.5, 8/03 Page- 2 FIG. 1: STEPS IN MOUNTING THE STRIKE Step four is to insert roll pins furnished with the stri ke. The pins are hammered into the strike but be careful not to hit them too hard as it is possible to raise dents on the strike surface by over driving the pins which degrades strike flatness and therefore holding force.
Rev. A.5, 8/03 Page- 3 FIG. 2: STANDARD MAGNET DIMENSIONS AND ASSEMBLY Blind Nut PN# BN-250 or PN# BN-6MM (Metric) (Pack of 40 with tool) Gold Washer PN# FW-1 (Pack of 24) Tamper Cap PN# FC-1 (Pack of 24) Length Width Depth 32 8" 1.88 1.5 (mm) 203 47.
Rev. A.5, 8/03 Page- 4 FIG. 3: STRIKE DIMENSIONS AND ASSEMBLY Once a solid flat surface has been prepared for the magnet, it must be positioned so that its face is parallel and centered to the strike plat e. When the magnet ha s been experimentally positioned this way, it's ready for mounting.
Rev. A.5, 8/03 Page- 5 FIG. 4: COLLAPSING THE BLIND NUTS HEADER TOOL BLIND NU T NUT AS SHOWN PRESS IN BLIN D COLLAPSES WHEN CAP SCREW IS T URN E D W IT H A LLE N W RE NC H WH IL E TO O L IS H E LD FAS.
Rev. A.5, 8/03 Page- 6 sheet rock do not constitute a secure mounting s ubstrate). Note that when the roll pin bushings are used, they protrude through the Z bracket and interfere with the Z bracket cover. If a Senstat lock is being employed, the roll pin bushings must be used to provide insulation.
Rev. A.5, 8/03 Page- 7 FIG. 7: F MAGNALOCK MOUNTING Sex Bolt Drill 1/2" (12.7mm) hole Washer Stack Header T-Nut requires 3/8" (9.5mm) Dia hole in bracket and accepts strike mounting screw Roll pin plastic bushing require 1/2" (12.7mm) holes and must be shortened to work in Z bracket.
Rev. A.5, 8/03 Page- 8 method is to space the magnet down so as to cl ear the blade stop. This generally requires 1/2” of spacing (12.7mm) and Securitron offers bra ckets of the appropriate width with pre-drilled clearance holes for the Magnet mounting screws.
Rev. A.5, 8/03 Page- 9 FIG. 9: USE OF THE UMB BRACKET WITH THE MODEL 34 MAGNALOCK STOP HEADER DOOR STRI KE MAGNET BLA DE UMB BRACKET ALUMINUM DOOR A ND FRAME WITH BL ADE STOP STOP HEADER DOOR STRI KE .
Rev. A.5, 8/03 Page- 10 2.5.4 DOUBLE DOOR MOUNTING Several possibilities exist for this application. In some cases, one of the door leaves is pinned so that only one leaf is used and this is secured by a single Magnalock. If both leaves are to be active, two Magnalocks can be used.
Rev. A.5, 8/03 Page- 11 FIG. 12: WOOD FRAME AND CONCRETE HEADER BRACKET S P L I C E C H A M B E R MA G NE T S C R E WS IN TO 4 OUTSIDE TAPPED HOLES 1/2" SHEET METAL SCREWS HEADER USED FOR C ONCR .
Rev. A.5, 8/03 Page- 12 alignment, side alignment and twisting. The Magnalo ck is also fully sealed and waterproof so it is generally unaffected by tough environments.
Rev. A.5, 8/03 Page- 13 The drawings and descriptions, show conceptual in stallation concepts for different types of gate security applications. Note that the model 62 and model 82 are most commonly used in gate installations.
Rev. A.5, 8/03 Page- 14 compatibility. Dress covers are available in clear aluminum, satin black aluminum, polished stainless and polished brass finishes. Double dress covers are also available for insta llations on double doors. In this case, the cover fits over two locks so long as they are not separated by more than 2" (50mm).
Rev. A.5, 8/03 Page- 15 wires, while observing correct pol arity. The lock, however, automatically detects whether it is receiving 12 or 24 volts and draws the correct amount of current for that voltage (the current is twice as high when the lock is re ceiving 12 volts than when it is receiving 24 volts).
Rev. A.5, 8/03 Page- 16 installations, the calculation can become quite complex so refer to Appendix B for a more complete discussion. Distance Gauge 12V Gauge 24V Distance Gauge 12V Gauge 24V 80 FT 20 GA 24 GA 800 FT 10 GA 16 GA 200 FT 17 GA 22 GA 1500 FT.
Rev. A.5, 8/03 Page- 17 3.7 DOUBLE DOOR CONTROL SWITCHING It’s common to control two locks from a single access and/or exit switch on double doors or on an installation where two locks ar e mounted on a single door.
Rev. A.5, 8/03 Page- 18 MAGNACARE ® LIMITED LIFETIME WARRANTY SECURITRON MAGNALOCK CORPORATION wa rrants that it will replace at cu stomer’s request, at any time for any reason, products manufac tured and branded by SECURITRON.
Rev. A.5, 8/03 Page- i APPENDIX A TROUBLESHOOTING PROBLEM -- No magnetic attraction betw een magnet and strike plate. First be sure the lock is being correctly powered with DC voltage. This includes connecting the power wires with correct polarity. Positive must go to red and negative to bla ck.
Rev. A.5, 8/03 Page- ii PROBLEM -- Apparent electronic noise interference w ith the access control system. Electric locks, being inductive devices, return voltage spikes on their power wires and also emit microwave radiation when switched. This can interfere with acce ss control electronics causing malfunctions.
Rev. A.5, 8/03 Page- iii Note that a Magnalock operating on 12 vo lts has 1/4th the resistance of a uni t operating on 24 VDC. This means that wire voltage drops are 4 times more significant in a 12 volt system than in a 24 volt system. In any job that has wire runs long enough to be of concern, alw ays use 24 volts.
Rev. A.5, 8/03 Page- iv attackers will not be familiar with it. Expecting a conv entional lock which secures between the door and frame, the attacker will employ the crowbar in an attempt to spread the door edge from the frame to clear the securing latch rather than to pry the door open against t he strength of the Magnalock.
Een belangrijk punt na aankoop van elk apparaat Assa Abloy 32 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Assa Abloy 32 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Assa Abloy 32 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Assa Abloy 32 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Assa Abloy 32 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Assa Abloy 32 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Assa Abloy 32 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Assa Abloy 32 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.