Gebruiksaanwijzing /service van het product 1000M van de fabrikant Nortel
Ga naar pagina of 458
Nortel Commu nication Serve r 1000 Nortel Commu nication Server 1000 Release 5 .5 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Document Number: NN43021-310 Document Release: Standard 02.01 Date: December 2007 Y ear Publish FCC TM Cop yright © 2007, Nor tel Networks.
.
Page 3 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 10 Contents Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 New in this release . . . . . . . . . . . . . . . . . . . . .
Page 4 of 456 Contents NN43021-310 Standard 0 2.01 December 2007 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Overview .
Contents Page 5 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Installing overhead cable tray kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 Installing DC power . . . . . . . . . . . . .
Page 6 of 456 Contents NN43021-310 Standard 0 2.01 December 2007 Connecting a system terminal or modem . . . . . . 171 Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171 About the system terminal .
Contents Page 7 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Cabling Common Equipment in a Multi Group system . . . . . . . . . . . . . . . . . . . . . . . . . 207 Contents . . . . . . . . . . . . . . . .
Page 8 of 456 Contents NN43021-310 Standard 0 2.01 December 2007 Cabling lines and trunks . . . . . . . . . . . . . . . . . . . . 261 Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 261 Overview .
Contents Page 9 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Installing seismic bracing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 344 Drilling concrete floors . . . . . . . . .
Page 10 of 456 Contents NN43021-310 Standard 0 2.01 December 2007.
Page 11 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 12 New in this release Features There are no new features in th is NTP for CS 1000 Release 5.5. Other Revision History Decem ber 20 07 Standard 02.01.
Page 12 of 456 New in this relea se NN43021-310 Standard 0 2.01 December 2007 April 2006 Standard 4.00. This document is up-issued with corrections from CR Q01311083. The correctio ns appear in the “Configuring the System Monitor' section ( page 153 to page 157 ).
Page 13 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 18 List of Procedures Procedure 1 Preparing the equipment for installation . . . . . . . . . . . . . . . . . . . . . 62 Procedure 2 Placing the fo urth module on a col umn .
Page 14 of 456 NN43021-310 Standard 0 2.01 December 2007 Procedu re 13 Installing a PF TU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148 Procedu re 14 Connecting trunks and telephones . . . . . . . . . . . . . . . .
Page 15 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Procedu re 29 Connecting the Core mo dule to a LAN . . . . . . . . . . . . . . . . . . . . . . . 205 Procedu re 30 Cabling the Core/Net modul e backplane .
Page 16 of 456 NN43021-310 Standard 0 2.01 December 2007 Procedu re 45 Cabling an IPE Module (NT8D37) or Media Gateway . . . . . . . . . . . 264 Procedu re 46 Connecting lin es and trunks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 266 Procedu re 47 Installing th e Security Device .
Page 17 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Procedu re 61 Sysload test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 339 Procedu re 62 Testing system term inal and system monitor .
Page 18 of 456 NN43021-310 Standard 0 2.01 December 2007 Procedu re 77 Connecting an HP DL 320-G4 Signaling Server . . . . . . . . . . . . . . . . 398 Procedu re 78 Installing Signali ng Server software . . . . . . . . . . . . . . . . . . . . . . . . .
Page 19 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 20 How to get help This section explains how to get help for Nortel products and services. Getting help from the Nortel Web site The best way to get technical support for Nortel product s is from the Nortel Technical Support Web site: www.
Page 20 of 456 How to get he lp NN43021-310 Standard 0 2.01 December 2007 Outside North America, go to the following Web site to obtain the phone number for your region: www.
Page 21 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 22 Finding the latest updates on the Nortel web site The content of this documentation was current at the time the product was released. T o check for updates to the latest documentation and software for CS 1000 Release 5.
Page 22 of 456 Finding the latest upd ates on the Nortel web site NN43021-310 Standard 0 2.01 December 2007.
Page 23 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 30 System information This document is a global document. Co ntact your system supplier or your Nortel representative to verify that th e hardware and software described are supported in your area.
Page 24 of 456 System information NN43021-310 Standard 0 2.01 December 2007 For this document, the CP PIV proce ssor is assumed in the cas e of the CS 1000M SG, Meridian 1 PBX 61C, CS 1000M M G, and Meridian 1 PBX 81C. If you are installin g a system with a CP PII processor, please refer to the CS 1000 Release 5 .
System information Page 25 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning • Meridian 1 Optio n 51 • Meridian 1 PBX 51C • Meridian 1 PBX 61C • Meri.
Page 26 of 456 System information NN43021-310 Standard 0 2.01 December 2007 understand the Communicatio n Server 10 00M and Meridian 1: Large System Overview (NN43021-110) befo re you install a system.
System information Page 27 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Related information This section lists informatio n sources that relate to this docum ent.
Page 28 of 456 System information NN43021-310 Standard 0 2.01 December 2007 • CS 1000M and Meridian 1 61C CP PII to CS 1000M MG CP PIV FNF Upgrad e (NN43021-465) • CS 1000M and Meridian 1 CS1000M .
System information Page 29 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Online To access Nortel documentation online, click the Technical Documentation link under Sup port & Training on the Nortel home page: www.
Page 30 of 456 System information NN43021-310 Standard 0 2.01 December 2007.
Page 31 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 36 Introduction Contents This section contains infor mation on the following topics: Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Page 32 of 456 Introduction NN43021-310 Standard 0 2.01 December 2007 Whenever possible, install external power equi pment be fore the system installation. If reserve power equipmen t is used, install it according to the manufacturer’s instructions.
Introduction Page 33 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Summary of procedures 1 Prepare equipment for installation; go to “Preparing the equipment for installation” on page 62 .
Page 34 of 456 Introduction NN43021-310 Standard 0 2.01 December 2007 11 Connect a system terminal (or mo dem); go to “Connecting a syst em terminal or modem ” on page 171 . 12 Install cabling: — To cable Common Equipmen t, go to “Cabling Common Equipment in a Single Group system” on page 18 7 .
Introduction Page 35 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Ta b l e 2 List of tasks in subsections T a sk Go to page Prepar ing f or installation.
Page 36 of 456 Introduction NN43021-310 Standard 0 2.01 December 2007.
Page 37 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 64 Preparing for installation Contents This section contains infor mation on the following topics: Requirements . . . . . . . . . . . . . . . . . . . .
Page 38 of 456 Preparing for installation NN43021-310 Standard 0 2.01 December 2007 Before system equipment is delivered to the installation site, you must consider these requirements: • Fire protec.
Preparing for install ation Page 39 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning • A System Monitor checks the colu mn’s cooling and power system s. • A blower unit (accessible from the fr ont of the pedestal) forces air up through the modules to cool the circuit cards.
Page 40 of 456 Preparing for installation NN43021-310 Standard 0 2.01 December 2007 • A red LED in the front of the cap’s exhaust grill that lights if the system overheats or if a power outage occurs. • Ladder racks for routing cables can also be fitted to the top caps.
Preparing for install ation Page 41 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 2 Example of Large System column row UEMs are identifi ed by function Each UEM contains a specialized set of equipment to dig italize, process, and route phone calls and voice messages (see Figure 3 on page 42 ).
Page 42 of 456 Preparing for installation NN43021-310 Standard 0 2.01 December 2007 Figure 3 UEMs identified by function Card cage Inside each UEM is a metal card cage. This card cage holds the circuit cards, power card, and related equi pment for that module.
Preparing for install ation Page 43 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Core/Net module Large Systems feature the NT4N41 Core /Net module. The Core/Net module provides a unified hardware plat form for single group and multi-g roup configurations.
Page 44 of 456 Preparing for installation NN43021-310 Standard 0 2.01 December 2007 Figure 4 NT4N41 Core/Net shelf fanout panel (backplane) j3 slot 9 por t 0 j4 slot 9 por t 0 Group 0 Group 1 Group 2 .
Preparing for install ation Page 45 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning System options The procedures in this document apply to the following s.
Page 46 of 456 Preparing for installation NN43021-310 Standard 0 2.01 December 2007 Figure 5 Meridian 1 PBX 61C s tacked configuration Figure 6 Meridian 1 PBX 61C side-by-side configuration Main colum.
Preparing for install ation Page 47 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Meridian 1 PBX 81C and CS 1000M MG These systems feature a dual Pentiu m Processor with standby processing capability, two Core/ Net modules installed side-by-sid e, and two or more network groups.
Page 48 of 456 Preparing for installation NN43021-310 Standard 0 2.01 December 2007 Figure 8 Three-tier mu lti-group system CP PIV A Call Processor Penti um IV (CP PI V) Large System processor was introduced for CS 1000 Release 4.
Preparing for install ation Page 49 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning New system types There are two new system types for CP PIV: • 3521 (M.
Page 50 of 456 Preparing for installation NN43021-310 Standard 0 2.01 December 2007 Figure 9 CP PIV call processor card (side) 512 MBytes DDR memory Fixed Media Drive (FMD) Removable Media Driv e (RMD.
Preparing for install ation Page 51 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 10 CP PIV call processor card (front) Removab le Media Drive ( R.
Page 52 of 456 Preparing for installation NN43021-310 Standard 0 2.01 December 2007 Signaling Server CS 1000M systems use a Sign aling Server. The Signaling Server provides a central processor to drive the si gnaling for IP Phones and IP Peer Networking.
Preparing for install ation Page 53 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 11 CS 1000M Large System Engineering rules Each system is defined using the follow ing assumptions and general engineering rules.
Page 54 of 456 Preparing for installation NN43021-310 Standard 0 2.01 December 2007 6 Sending and receiving cables must be of equal lengths and as short as possible. 7 In order to optimize network FIJI cabling, mou nt the NTD35 network modules in pairs in th e same column, one module on top of the other in the middle tiers.
Preparing for install ation Page 55 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 1 2 Cable routi ng troughs – front view of module A typical ro.
Page 56 of 456 Preparing for installation NN43021-310 Standard 0 2.01 December 2007 Since all faceplate to I/O panel cables are the same length and card positions in the card cage vary, a cable can co ntain excess slack.
Preparing for install ation Page 57 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 2 Vertically on the sides of the module 3 Vertically in the corner chan.
Page 58 of 456 Preparing for installation NN43021-310 Standard 0 2.01 December 2007 Figure 1 5 180° cable connector Equipment handling precauti ons To avoid personal injury and equ ipment damage, review the following guidelines before h andling the equipm ent.
Preparing for install ation Page 59 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Working with power supplies There are no user-repairable componen ts in the power supply. If a power supply fails, the complete unit must be replaced.
Page 60 of 456 Preparing for installation NN43021-310 Standard 0 2.01 December 2007 Figure 1 6 Static discharge points Wrist strap connection point Bare metal strip 553-5000 Wrist strap connection poi.
Preparing for install ation Page 61 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning DenAn regulatory notice for Japan.
Page 62 of 456 Preparing for installation NN43021-310 Standard 0 2.01 December 2007 Preparing the equipment for installation Use the equipment room floor plan to position equipment. See Communication S erver 100 0M and Meridian 1: Larg e System Plan ning and Engineering (NN43021-220) to prepare the eq uipment room and floor plan.
Preparing for install ation Page 63 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning a. With a flat blade screwdriver, turn the lock clockwi se on the two locking latches (see Figure 17 on page 63 ). Figure 1 7 Locking latches on the module cover b.
Page 64 of 456 Preparing for installation NN43021-310 Standard 0 2.01 December 2007 Figure 1 8 Removing the pe destal grill 4 Make sure all of the items on th e system order form are on the pac king slip that comes with the equipment. 5 Inspect all equipment for physical dama ge.
Page 65 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 70 Placing the fourth module on a column Contents This section contains infor mation on the following topics: Overview . . . . . . . . . . . . . . . .
Page 66 of 456 Placing the fourth module on a column NN43021-310 Standard 0 2.01 December 2007 Procedure 2 Placing the f ourth module on a col umn 1 Position and secure the fourth module. a. Locate the positioni ng guides on t he third module (see Fig ure 19).
Placing the fourth module on a column Page 67 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 1 9 Module positio ning guides Positioning guides Rear.
Page 68 of 456 Placing the fourth module on a column NN43021-310 Standard 0 2.01 December 2007 Figure 2 0 Module mount ing bolts 2 Connect the module-to-module pow er and system monitor cables. a. Connect the power co nnectors between the modules (see Figure 21 on page 69 ).
Placing the fourth module on a column Page 69 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 2 1 Power and system monitor conn ections 3 Reinstall the I/O safety panel in each module. 4 Replace the module covers.
Page 70 of 456 Placing the fourth module on a column NN43021-310 Standard 0 2.01 December 2007.
Page 71 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 76 Positioning and leveling equipment Contents This section contains infor mation on the following topic: Positioning and leveling the equipment . . .
Page 72 of 456 Positioning and leveling equipment NN43021-310 Standard 0 2.01 December 2007 c. Position a level across the top mod ule cover on the front of the column. d. Loosen the locking nuts on the feet. e. Adjust the feet on each pedesta l up or down to level the column.
Positioning and leveling eq uipmen t Page 73 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 2 2 Positioning spacer gaskets f. Attach a spacer to one side of e ach module, except the en d column (see Figures 23 and 24).
Page 74 of 456 Positioning and leveling equipment NN43021-310 Standard 0 2.01 December 2007 Figure 2 3 Spacer positioning Spacer Screw Stand-off 553-A0130 Rear Spacer.
Positioning and leveling eq uipmen t Page 75 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 2 4 Column positi onin g with spacers End of Procedure .
Page 76 of 456 Positioning and leveling equipment NN43021-310 Standard 0 2.01 December 2007.
Page 77 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 88 Installing AC power Contents This section contains infor mation on the following topics: AC-powered systems. . . . . . . . . . . . . . . . . . . . .
Page 78 of 456 Installing AC power NN43021-310 Standard 0 2.01 December 2007 Systems that u se reserve power plug i nto the UPS, which in turn plugs in to the power source (associated batteries can be located within the UPS or installed externally). Con sult th e UPS documentation for receptacle requirements.
Installing AC power Page 79 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Multiple-column sy stems use an insulated ground bus as the point where the logic return wires from di fferent columns are conso lidated before connecting to the single-point ground.
Page 80 of 456 Installing AC power NN43021-310 Standard 0 2.01 December 2007 Figure 2 6 Multiple colu mn – ground and logic return distribution AC input Service panel 120 V receptacle IG or ACEG Cor.
Installing AC power Page 81 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 27 Multiple column, mu ltiple r ow – gro und and lo gic return distrib.
Page 82 of 456 Installing AC power NN43021-310 Standard 0 2.01 December 2007 Installing safety ground /protective earth and logic return wiring Follow Procedur e 4 to install sa fety ground/prot ective earth and logic return wiring.
Installing AC power Page 83 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 2 8 PDU ground lug lo cations 4 Connect the safety groun d/protecti ve earth wire (insulated ground wire must be used for syst em grounding).
Page 84 of 456 Installing AC power NN43021-310 Standard 0 2.01 December 2007 5 Place a warning tag on the connecti on at the ground source. The warning tag should read WARNING—TEL EPHONE SYSTEM GROUND CONNECTION—DO NOT DISCONNECT.
Installing AC power Page 85 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Installing UPS ground cabling Use the manufacturer’s documents to inst all and cable a UPS. If the UPS does not contain an integral byp ass switch, add one externally duri ng initial U PS wiring.
Page 86 of 456 Installing AC power NN43021-310 Standard 0 2.01 December 2007 Procedure 5 Installing the UPS gr ound cab ling 1 Make sure the safety grou nd/protec tive earth wire is connected on all Large System columns. 2 Daisy-chain ground cables to each UPS (see Figure 32) using #6 AWG wire.
Installing AC power Page 87 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 3 2 UPS grounding diagram 0 Column frame grounds UPS frame grounds Bypas.
Page 88 of 456 Installing AC power NN43021-310 Standard 0 2.01 December 2007.
Page 89 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 92 Installing overhead cable tray kits Contents This section contains infor mation on the following topic: Installing overhead cable tray kits . . . .
Page 90 of 456 Installing ove rhead cable tray kits NN43021-310 Standard 0 2.01 December 2007 Procedure 6 Installing the overhead cable tra y kits 1 Remove air exhaust grills at the front and rear of the top ca p. Pull forward on the two clips underneath the front edge of each grill and lift up to remove the grill (see Figure 33).
Installing overhead cable tray kits Page 91 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 3 4 Overhead cable tray kit 3 Install the front an d rear air exhau st grills that come with the ki t.
Page 92 of 456 Installing ove rhead cable tray kits NN43021-310 Standard 0 2.01 December 2007.
Page 93 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 132 Installing DC power Contents This section contains infor mation on the following topics: DC-powered systems. . . . . . . . . . . . . . . . . . . .
Page 94 of 456 Installing DC power NN43021-310 Standard 0 2.01 December 2007 Note: The procedures in this chap ter apply to the global power distribution uni t (PDU). Throughout th is document, th e global PDU is referred to as the NT4N49AA PDU. To install reserve power equipment (b atteries), fol low the instructions provided with the equipmen t.
Installing DC powe r Page 95 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Both Large and Small Candeo systems provide “plug and walk-away” installation and setup. The platfo rm can be reconfigured or expand ed while it remains online.
Page 96 of 456 Installing DC power NN43021-310 Standard 0 2.01 December 2007 Note 2: The Large Candeo system generally requires one input receptacle for each rectifier, within 1.8 m (6 ft) of each rectifier. The commercial power receptacles requi red are determined by the number and type of rectifiers used.
Installing DC powe r Page 97 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Large Candeo modules The Candeo platform uses a comb ination of modules or building bl ocks to deliver custom configurat ions.
Page 98 of 456 Installing DC power NN43021-310 Standard 0 2.01 December 2007 System Manage r Module The System Manager is the main co ntrol element of the Large Candeo system. The System Manager’s local and remote system management capabilities provide total cont rol over the power system.
Installing DC powe r Page 99 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Distribution Module features include: • Wide selection of di stribution elem.
Page 100 of 456 Installin g DC power NN43021-310 Standard 0 2.01 December 2007 Large Candeo sample configurations Example configuration #1 • 1.05 m (42 in.) Frame with battery kit, LVD and distributi on 500 (with 20 breaker positions). • 17 mid trip breakers (30 A), one GMTX fuse block (tak es up 3 breaker positions).
Installing DC power Page 101 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Small Candeo modules The Candeo platform uses a comb ination of modules or building bl ocks to deliver custom configurat ions.
Page 102 of 456 Installin g DC power NN43021-310 Standard 0 2.01 December 2007 capacity of the supplementary shelf is 180 A (six rectifiers de livering 30 A each), but the sixth rectifier is for N+1 redundancy and kicks in only if one of the other rectifiers fail s.
Installing DC power Page 103 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning • remote or local access (PSTN, GSM, EEM, TCP/IP, SNMP) • local and remote.
Page 104 of 456 Installin g DC power NN43021-310 Standard 0 2.01 December 2007 Enclosure, an enclosed shelf for use in Candeo racks. Each battery shelf can accommodate two modules, for a total of eight batteries.
Installing DC power Page 105 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Example configuration #2 A 300 A system: • initial power shelf equipped with.
Page 106 of 456 Installin g DC power NN43021-310 Standard 0 2.01 December 2007 Figure 3 6 Small Candeo 300 A system with sup plementary distribu tion panel Installation re ference guide The Candeo system is easy to install.
Installing DC power Page 107 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Installati on Manual (P7000289) fo r the Small Candeo system. The installation manuals cover the follow ing topics. Large Candeo 1 Site Preparation — Overview, tools a nd test equipment, precautions, and receiving materials.
Page 108 of 456 Installin g DC power NN43021-310 Standard 0 2.01 December 2007 3 Cabling and connecting — Basic rule s, specifications for connecting lugs, torqu e values for bolted lug to bu s bar .
Installing DC power Page 109 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 8 Abbreviations an d Acronyms 9 Technical Service Assistance Small Candeo 1 In.
Page 110 of 456 Installin g DC power NN43021-310 Standard 0 2.01 December 2007 To eliminate potential of system pro blems and ensure the best grounding method possible is used, obtain th e servi ces of a certified power contractor or auditor prior to system instal lation or cutover.
Installing DC power Page 111 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Note 1: In some equipment sites, dep ending on the gro unding topology and the size of the building, the flo or ground bar (FGB) and the building principal ground (BPG) may be the same bu sbar.
Page 112 of 456 Installin g DC power NN43021-310 Standard 0 2.01 December 2007 Note 1: The frame ground collector cable is normally sized according to its length (distance between the m ain DC distribution cabinet and the FGB or BPG) as well as the maximum fuse or circuit breaker size that can be provided in the power pl ant.
Installing DC power Page 113 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Procedure 7 Installing and connecting the power plant frame gr ound leads 1 Us.
Page 114 of 456 Installin g DC power NN43021-310 Standard 0 2.01 December 2007 2 Connect the other end of the cable to th e FG collector with a parallel tap connector, as shown in the left side illustration of Figure 37 on page 114 . Continue with step 4.
Installing DC power Page 115 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 38 Connection of the frame ground lead inside the frame 553-AAA0759.
Page 116 of 456 Installin g DC power NN43021-310 Standard 0 2.01 December 2007 Figure 39 Ground and logic return distri bution – Large and Small Candeo power sy stems AC input Service panel IG or AC.
Installing DC power Page 117 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Four-Feed PDU The Four-Feed PDU (NT4N49AA) suppor ts independent power feeds to each of four modules in a stack if requ ired.
Page 118 of 456 Installin g DC power NN43021-310 Standard 0 2.01 December 2007 The four breakers (one for each module) in the existing DC PDU (NT4N50AA) are rated at 18 A each. Th e same breakers in the four-feed PDU are rated at 28 A. Figure 41 Optional four -feed wiring A readily accessible disconnect de vice for input power is required.
Installing DC power Page 119 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 4 2 PDU circuit protectio n NT4N49AA PDU T er minal bloc k - 48 V sourc.
Page 120 of 456 Installin g DC power NN43021-310 Standard 0 2.01 December 2007 A maximum loop drop of 2 V is allowe d between the pedestal, or junction box, and the external power equipment.
Installing DC power Page 121 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning The following equipment is located in the rear of each pedestal (see Figure 43) in Large System columns. • The PDU distributes powe r to the entire column.
Page 122 of 456 Installin g DC power NN43021-310 Standard 0 2.01 December 2007 With the NT4N49AA PDU, the safety ground/ protective ear th wires and all wiring to the terminal blo ck in the PDU must be neatly routed within the cable-tie saddles and under the cable rest raint bar at the base of the pedestal (see Figure 44 on page 122 ).
Installing DC power Page 123 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Installing the Four-Feed PDU Installing the NT4N 49AA PDU is a two-step process.
Page 124 of 456 Installin g DC power NN43021-310 Standard 0 2.01 December 2007 next as illustrated in Figure 45, connecting all of the columns together (or run a #6 AWG wire fr o m the ground source to each column indivi dually). Note 1: Use only insulated ground wire for system grounding.
Installing DC power Page 125 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Connecting power from th e power plant to the PDU Note 1: It is good installation practice to fully wire out a pe destal, even if only one or two columns are being installed at first.
Page 126 of 456 Installin g DC power NN43021-310 Standard 0 2.01 December 2007 c. Connect the wires to the ma tching conne ctions on the terminal block on the junction box. i. Connect the red wires to – BAT 0, – BAT 1, – BAT 2, and – BAT 3. ii.
Installing DC power Page 127 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 10 Replace the metal safety cover over the terminal bl ock on the PDU. a. Lower the front panel over th e mounting screws on the PDU.
Page 128 of 456 Installin g DC power NN43021-310 Standard 0 2.01 December 2007 Figure 46 PDU to Large Candeo connections End of Procedure 553-AAA0760.
Installing DC power Page 129 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Connecting UK power to the Four-Feed PDU To connect the external power system to the pedestal, use t he following procedure for each column (this procedure gives the connections for a four-module col umn).
Page 130 of 456 Installin g DC power NN43021-310 Standard 0 2.01 December 2007 4 Connect the black BATRTN (+ 48 V) wires. a. At the 8B/2R or 8B/4R master power cabin et, connect wires to the +ve bus. b. At the PDU, connect the wires to the terminal block: i.
Installing DC power Page 131 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 47 UEM to 8B/2R or 8B/4R mast er power cabinet connections TB1 in P owe.
Page 132 of 456 Installin g DC power NN43021-310 Standard 0 2.01 December 2007.
Page 133 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 144 Planning and designating a Main Distribution Frame Contents This section contains infor mation on the following topics: About terminations . . . .
Page 134 of 456 Planning and designating a Main Distribution Frame NN43021-310 Standard 0 2.01 December 2007 This chapter describes how to install and connect a CS 1 000M system using the BIX or Krone Test Jack Fram e (UK) cross-connect terminals. Note: The examples shown here are BIX and Krone cross-connect systems.
Planning an d designating a Mai n Distri bution F rame Page 135 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Pr ocedure 11 Installing the BIX cr oss-connect terminal 1 Refer to the equipment layout plan to determine where to place the cross-connect terminal .
Page 136 of 456 Planning and designating a Main Distribution Frame NN43021-310 Standard 0 2.01 December 2007 Figure 4 9 BIX module Connector Designation strip 553-3097.
Planning an d designating a Mai n Distri bution F rame Page 137 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 5 0 Recommended layout fo r NT8D37 I.
Page 138 of 456 Planning and designating a Main Distribution Frame NN43021-310 Standard 0 2.01 December 2007 Installing the Krone cros s-connect system (UK) In the Krone cross-connect system, one termi nating strip holds ten pairs of cable.
Planning an d designating a Mai n Distri bution F rame Page 139 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 5 1 IPE module car d allocati on –.
Page 140 of 456 Planning and designating a Main Distribution Frame NN43021-310 Standard 0 2.01 December 2007 Figure 5 2 CE/PE modul e card allo cation – Krone cross- connect sy stem Labels Terminating strips on the Krone cross-c onnect must be labeled if they contain wiring.
Planning an d designating a Mai n Distri bution F rame Page 141 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning There are two types of mandatory labels: th ose with safety warnings and those without.
Page 142 of 456 Planning and designating a Main Distribution Frame NN43021-310 Standard 0 2.01 December 2007 Figure 5 4 Label for Analog Tie T runk Card Figure 5 5 Label for Data Access Line Card (NT .
Planning an d designating a Mai n Distri bution F rame Page 143 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 5 6 Label for Power Failure Transfer Unit Figure 5 7 Label for Digital Line Card (NT8D02) SAFETY WARNING SEE INSTRUCTIONS FOR USE POWER FAIL TRANSFER UNIT CABLE J1.
Page 144 of 456 Planning and designating a Main Distribution Frame NN43021-310 Standard 0 2.01 December 2007 Figure 5 8 Label for Exchan ge Line Trunk Card (NT5K 18) Figure 5 9 Label for Direc t Dial Inward Trun k Card (NT5K17) 553-6466 EXCHANGE LINES LOOP.
Page 145 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 150 Installing Power Failure Transfer Units Contents This section contains infor mation on the following topics: PFTU configurations . . . . . . . . .
Page 146 of 456 Installin g Power Fai lure Transfer Units NN43021-310 Standard 0 2.01 December 2007 5 Designated telephones (DTMF or rotary dial types) 6 Central office trunks Figure 60 MDF terminations for ty pical PFTU op eration Figure 61 on page 147 shows detail view of the PFTU alarm connections.
Installing Power Failure Transfer Uni ts Pag e 147 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 61 Typical PFTU co nnection to the MDF and the Ma.
Page 148 of 456 Installin g Power Fai lure Transfer Units NN43021-310 Standard 0 2.01 December 2007 Installing a PFTU Use the following procedure and any in structions provided with the Power Failure Transfer Unit (PFTU) to install and connect PFTUs. Pr ocedure 13 Installing a PFTU 1 Install a PFTU according to the manufacturer’s in structions.
Installing Power Failure Transfer Uni ts Pag e 149 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning c. Connect a #24 (or larger) AWG wire from the ground (GND) connection on the auxi liary power supply to th e PFTU termination area on the MDF.
Page 150 of 456 Installin g Power Fai lure Transfer Units NN43021-310 Standard 0 2.01 December 2007 2 For each trun k assigned to the PFTU. • Connect the tip and ring of the CO card to the third pair of the assigned PFTU. • Connect the tip and ri ng of the trunk to the fourth p air of the assigned PFTU.
Page 151 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 170 Configuring the system monitor Contents This section contains infor mation on the following topics: System monitor cabling . . . . . . . . . . . .
Page 152 of 456 Configuring the system monitor NN43021-310 Standard 0 2.01 December 2007 Figure 6 2 System monitor to system m onitor serial link cabling Power failure transfer control The system monitor can be cabled to the MDF to provide power f ailure transfer control or additional alarms .
Configuring the system monitor Page 153 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Configuring the System Monitor The master System Monitor (NT8D22) in terfaces with a Serial Data Interface (SDI) port in the colum n with CPU 0.
Page 154 of 456 Configuring the system monitor NN43021-310 Standard 0 2.01 December 2007 with CPU 1 as slave unit 1. Number the slaves sequen tially wherever possible.
Configuring the system monitor Page 155 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 4 on on on off on on 36 off on on off on on 5 on on on off on off 3.
Page 156 of 456 Configuring the system monitor NN43021-310 Standard 0 2.01 December 2007 Ta b l e 1 1 SW2 on slaves —total unit number for the slaves (Part 1 of 2) Slave unit address Switch po sitio.
Configuring the system monitor Page 157 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning End of Procedure Cabling the System Monitor The System Monitor (NT8D22) is used to monitor the temperature, power supplies, and blow er unit in a colum n.
Page 158 of 456 Configuring the system monitor NN43021-310 Standard 0 2.01 December 2007 Figure 6 3 System monitor modu le-to-module cabling Follow the steps in Procedu re 16 to cable the NT8D22 System Monitor. Pr ocedure 16 Cabling the System Monitor (NT8D22) 1 Remove the I/O safety panel in the rear of the module with CPU 0.
Configuring the system monitor Page 159 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 3 Connect the master system monito r to slave unit 1 with an NT8D46AS cable.
Page 160 of 456 Configuring the system monitor NN43021-310 Standard 0 2.01 December 2007 Figure 6 5 Cabling CS 1000M SG or Meridian 1 PBX 61C, single column with stacked Core/Net modul es – cable master system monitor to SDI port 5 Daisy-chain slave system monitors to the m aster.
Configuring the system monitor Page 161 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 66 Multiple-column syste m monitor connections 6 For PFTU or external alarm cablin g, connect a system monitor to MDF cable.
Page 162 of 456 Configuring the system monitor NN43021-310 Standard 0 2.01 December 2007 Note 1: The system mo nitor to MDF cable is available in thre e lengths: NT8D46BH (9.
Configuring the system monitor Page 163 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 7 For AC-powered syst ems with a UPS: a. Connect the appropri ate cable (see the fo llowing list) from connector J4 on the system monitor in the column with CPU 0 (the master system monitor) to the associat ed UPS.
Page 164 of 456 Configuring the system monitor NN43021-310 Standard 0 2.01 December 2007 Figure 6 7 UPS alarm cabling 8 For DC-powere d systems, extend th e alarm and trip leads from connector J4 on t.
Configuring the system monitor Page 165 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Alarm interfacing to Candeo The Candeo interfaces with the system through th e Candeo's System Manager alarm output ports.
Page 166 of 456 Configuring the system monitor NN43021-310 Standard 0 2.01 December 2007 • remote access — by means of the web browser on a computer connected through a dial-up networ k connection.
Configuring the system monitor Page 167 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning •M a i n A C f a i l • Rectifier fail major (RF A major) • Lo.
Page 168 of 456 Configuring the system monitor NN43021-310 Standard 0 2.01 December 2007 Cabling the Candeo There are eight configurable Candeo output ports for ou tput alarms. Each output port can use one of the following th ree contact types: normally open, normally closed, and common.
Configuring the system monitor Page 169 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Pr ocedure 17 Configuring the alarm ports 1 Select “Alarm Severity and Output” from the System Manager display screen.
Page 170 of 456 Configuring the system monitor NN43021-310 Standard 0 2.01 December 2007.
Page 171 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 186 Connecting a system terminal or modem Contents This section contains infor mation on the following topics: About the system terminal. . . . . . .
Page 172 of 456 Connecting a system terminal or modem NN43021-310 Standard 0 2.01 December 2007 Figure 6 8 Terminal connection diagram During the initial installat ion of a dual CPU system, you may want to temporarily install addi tional terminals for split mo de monitoring, or programming, or both.
Connecting a system terminal or modem Page 173 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Connecting a terminal During the sy stem installation and fo.
Page 174 of 456 Connecting a system terminal or modem NN43021-310 Standard 0 2.01 December 2007 Terminals connected to the COM1 por ts can be installed as follows.
Connecting a system terminal or modem Page 175 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 69 One terminal for the COM1 ports Connecting a switch box and terminal to COM1 and COM2 ports Use Procedure 19 to connect COM1 ports to a switch box and a terminal (see Figure 70 on page 176 ).
Page 176 of 456 Connecting a system terminal or modem NN43021-310 Standard 0 2.01 December 2007 5 To communicate directly with a COM1 port, switch the ca ble as needed. The termin al connected to the SDI port will alwa ys communicate with whichever CPU is active.
Connecting a system terminal or modem Page 177 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Connecting a switch box and terminal to SDI and COM1 ports Use Procedure 20 to connect COM1 ports to a switch box and a terminal (see Figure 70 on page 176 and Figure 7 1 on page 178 ).
Page 178 of 456 Connecting a system terminal or modem NN43021-310 Standard 0 2.01 December 2007 Figure 7 1 One terminal and a switch box to the SDI an d COM1 ports Connecting a modem A modem must be connecte d to an SDI port in a network slot. The modem provides an I/O interface to the activ e CPU in the system for remote access.
Connecting a system terminal or modem Page 179 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning You can connect a modem to one of the fo llowing: 1 An SDI p.
Page 180 of 456 Connecting a system terminal or modem NN43021-310 Standard 0 2.01 December 2007 Configuring a modem Use Procedure 21 to configure the m odem. Yo u must confi gure the modem before you connect it to the Large System. A terminal, such as a PC computer, is required to conf igure the modem.
Connecting a system terminal or modem Page 181 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 6 Disconnect the power cord and serial from the modem. 7 Set DIP switches 1 and 4 to ON (down) and the remaining switches OFF (up).
Page 182 of 456 Connecting a system terminal or modem NN43021-310 Standard 0 2.01 December 2007 3 At the local end, configure the modem. Follow the manufactu rer’s instructions to set the modem for 9600 baud, auto answer, dumb mode, command recogniti on OFF, command echo OFF.
Connecting a system terminal or modem Page 183 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 7 2 Modem to SDI port Connecting a modem to switch bo.
Page 184 of 456 Connecting a system terminal or modem NN43021-310 Standard 0 2.01 December 2007 3 At the local end, configure the modem. Follow the manufactu rer’s instructions to set the modem for 9600 baud, autoanswer, dumb mode, command recognition OFF, and command echo OFF.
Connecting a system terminal or modem Page 185 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 7 3 Modem to a switch box and SDI and COM2 ports (dual- column sys tems) Rear View 553-A0137 Note: The A0377992 switch box and A0381391 modem can be used in this configuration.
Page 186 of 456 Connecting a system terminal or modem NN43021-310 Standard 0 2.01 December 2007 Figure 7 4 Modem to a switch box and SDI and COM2 ports (single-column systems) 553-A0138 NT8D95 cable S.
Page 187 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 206 Cabling Common Equipment in a Single Group system Contents This section contains infor mation on the following topics: Cabling guidelines . . . .
Page 188 of 456 Cabling Common Equipment in a Single Group system NN43021-310 Standard 0 2.01 December 2007 the secondary shrouds, which provide mechanical gu idance for cable connectors. Because the cable troughs and spaces on th e sides of a module are within the EMI shielding of the system, unshielded cables can be routed in those areas.
Cabling Common Equipment in a Single Grou p system Page 189 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 75 NT4N41 Core/Net shelf fa nout panel (backplane) Core/Net module The Core/Net modules contain two distin ct sets of circuit cards: Core cards and Network cards.
Page 190 of 456 Cabling Common Equipment in a Single Group system NN43021-310 Standard 0 2.01 December 2007 Reviewing Core/Net module placement Core/Net modules can b e installed side-by -side on top of separate pedestals (see Figure 76) for power and coo ling redundancy or in a stacked configuration (see Figure 77) in a single column.
Cabling Common Equipment in a Single Grou p system Page 191 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 7 7 Side-by-side configurat io n of Core.
Page 192 of 456 Cabling Common Equipment in a Single Group system NN43021-310 Standard 0 2.01 December 2007 Reviewing required Core cards All Core cards are installed in the f actory. See Table 19 for the Core card requirements for each Core/Net modu le.
Cabling Common Equipment in a Single Grou p system Page 193 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 2 NT4N48 System Utility card . The System Utility card is located in slot c15. 3 NT4N39AA Call Processor PIV (CP PIV) .
Page 194 of 456 Cabling Common Equipment in a Single Group system NN43021-310 Standard 0 2.01 December 2007 Figure 78 Core/Net cable c onnections (top view) NT4N29 3PE Cables to Net module (factory in.
Cabling Common Equipment in a Single Grou p system Page 195 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 7 9 CP PIV Core and Network backplanes Cabling the I/O panel Connect the cables from the CP PIV car d faceplate to the I/O panel on the back of the Core/Net modules.
Page 196 of 456 Cabling Common Equipment in a Single Group system NN43021-310 Standard 0 2.01 December 2007 Pr ocedure 24 Installing the CP PIV to I/O pane l cables 1 Connect COM1 on the CP PIV faceplate to J25 on the I/O pa nel with cable NT4N88AA. 2 Connect COM2 on the CP PIV facepl ate to J21 on the back of the I/O panel with cable NT4N88BA.
Cabling Common Equipment in a Single Grou p system Page 197 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Cabling the Network side Table 22 lists the number of circuit cards required by each system. Table 23 lists the number of net cab les required by each system.
Page 198 of 456 Cabling Common Equipment in a Single Group system NN43021-310 Standard 0 2.01 December 2007 Figure 80 CP PIV Core/N et Module slo t Configuring and cabling the Clock Controllers Two Clock Controller cards (NTRB53) are required in each system to synchronize functions.
Cabling Common Equipment in a Single Grou p system Page 199 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Pr ocedure 25 Connecting the Clock Contr oller cables See Figure 84 on page 205 . 1 Connect P1 of the NT8D75 cable to port J3 of Clock Controller 0.
Page 200 of 456 Cabling Common Equipment in a Single Group system NN43021-310 Standard 0 2.01 December 2007 Pr ocedure 26 Connecting the 3PE faceplates in the Core/Net modules 1 Connect a NT8D80 cable fro m the J4 port in the Core/Net 0 3PE card to J4 port in the Core/Net 1 3PE card.
Cabling Common Equipment in a Single Grou p system Page 201 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning a. Use the extracti on tool to disconn ect the NT4N29 cables from the Core backplane. b. Connect the cables to the appropri ate group (see Table 2 4).
Page 202 of 456 Cabling Common Equipment in a Single Group system NN43021-310 Standard 0 2.01 December 2007 Connecting the Core/Net backplanes The Shelf 0 and Shelf 1 backplanes mu st be connected with two NT8D99AD cables (Core/Net modules only).
Cabling Common Equipment in a Single Grou p system Page 203 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Optioning the System Utility Card To install the system utility card, fi rst identify Core/Net 0 and Core/Net 1 shelves.
Page 204 of 456 Cabling Common Equipment in a Single Group system NN43021-310 Standard 0 2.01 December 2007 Connecting Core modules to a LAN Connect each Core/Net module to a local area network (LAN). This connection provides a communi cation channel for LAN based systems management tools such as OTM, Symposium, CallPilot and Elem ent Manager.
Cabling Common Equipment in a Single Grou p system Page 205 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 8 4 CP PIV to I/O panel connections Pr ocedure 29 Connecting the Core modu le to a LAN 1 Label both sides of two customer supplied Ethernet cables.
Page 206 of 456 Cabling Common Equipment in a Single Group system NN43021-310 Standard 0 2.01 December 2007 Figure 8 5 Options for LAN 1 connections End of Procedure 553-A0145 Systems with a LAN switch: 1.
Page 207 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 238 Cabling Common Equipment in a Multi Group system Contents This section contains infor mation on the following topics: Cabling guidelines . . . . .
Page 208 of 456 Cabling Common Equipm ent in a Multi Group system NN43021-310 Standard 0 2.01 December 2007 which faces the front of the module, contains the primary shrouds, which provide mechanical guidance for the pi ns of the card edge connectors.
Cabling Common Equipmen t in a Multi Group system Page 209 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 86 NT4N41 Core/Net shelf fa nout panel (backplane) A label kit is included in the system package.
Page 210 of 456 Cabling Common Equipm ent in a Multi Group system NN43021-310 Standard 0 2.01 December 2007 Reviewing Core/Net module placement Core/Net modules are installed side-by-si de on top of separat e pedestals, for power and cooling redundancy.
Cabling Common Equipmen t in a Multi Group system Page 211 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 8 7 Side-by-side placement of CP PIV Core.
Page 212 of 456 Cabling Common Equipm ent in a Multi Group system NN43021-310 Standard 0 2.01 December 2007 Checking Core card (front side) installation All Core cards are factor y installed. The Core cards (front s ide) are: 1 NT4N65 cPCI Core Network Interface (cCNI) cards .
Cabling Common Equipmen t in a Multi Group system Page 213 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Pr ocedure 30 Cabling the Core/Net modu le backpl ane 1 Orient the cable connector so the st ra in relief paddl e is to the right.
Page 214 of 456 Cabling Common Equipm ent in a Multi Group system NN43021-310 Standard 0 2.01 December 2007 Pr ocedure 31 Disconnecting cable connect or s fr om the bac kplane Use extreme caution to avoid bending or breaking backplane pins. Do not insert the e xtraction tool unless the cabl e connector is locked in to the securing clip.
Cabling Common Equipmen t in a Multi Group system Page 215 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Optioning the System Utility Card To install the system utility card, fi rst identify Core/Net 0 and Core/Net 1 shelves.
Page 216 of 456 Cabling Common Equipm ent in a Multi Group system NN43021-310 Standard 0 2.01 December 2007 Figure 8 8 Core card placement in the NT4N41 Core/Net Module (fr ont) Core shelf cabling This section describes installation of the internal Core ca bles (see Figure 90 on page 219 ).
Cabling Common Equipmen t in a Multi Group system Page 217 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 89 Card placement in th e NT4N41Core/Net Module Required Core cabl es Table 28 on page 217 lists field installed cables.
Page 218 of 456 Cabling Common Equipm ent in a Multi Group system NN43021-310 Standard 0 2.01 December 2007 Customer supplied Standard CAT5 Ether net cable (I/O P anel to LAN s witch) 2 Note: If there is no connecti on to a LAN, conn ect the two LAN 1 connectors using the NTRC17BA crossov er cable.
Cabling Common Equipmen t in a Multi Group system Page 219 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 90 Core/Net cable c onnections (top view).
Page 220 of 456 Cabling Common Equipm ent in a Multi Group system NN43021-310 Standard 0 2.01 December 2007 Figure 9 1 CP PIV Core and Network backplanes Installing the CP PIV to I/O panel cables Connect the cables from the CP PIV car d faceplate to the I/O panel on the back of the Core/Net modules: • COM1 is used to connect a termina l.
Cabling Common Equipmen t in a Multi Group system Page 221 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 92 on page 222 displays the COM and LAN cable conn ections.
Page 222 of 456 Cabling Common Equipm ent in a Multi Group system NN43021-310 Standard 0 2.01 December 2007 Figure 9 2 I/O panel connecti ons End of Procedure Enb Dis SYS UTIL USB INIT RESET COM 2 cCN.
Cabling Common Equipmen t in a Multi Group system Page 223 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Connecting the Core module to a LAN Connect each Core/Net module to a local area network (LAN).
Page 224 of 456 Cabling Common Equipm ent in a Multi Group system NN43021-310 Standard 0 2.01 December 2007 Figure 9 3 Options for LAN 1 connections End of Procedure Cabling a Dual Ring Fiber Network The FIJI cards in the Network modules are connected to form a Dual Ring Fiber Network.
Cabling Common Equipmen t in a Multi Group system Page 225 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning (Figure 94 on page 225 ). Four st eps are required to configure t he Fiber Network: • “Installing the Shelf 0 fiber opti c ring (ascending)” on page 231 .
Page 226 of 456 Cabling Common Equipm ent in a Multi Group system NN43021-310 Standard 0 2.01 December 2007 Required cards Table 30 on page 226 outlines the number of circ uit cards required by each system depends on system configuration. Required cables Table 31 on page 226 outlines the required cabl es.
Cabling Common Equipmen t in a Multi Group system Page 227 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning NTRC46BB 1.65 m to 2.4 m (5.5 ft. to 8 ft)* NTRC46CB 6 . 7m ( 2 2f t ) * Clock to Cloc k 1 per system NTRC49AA 1.
Page 228 of 456 Cabling Common Equipm ent in a Multi Group system NN43021-310 Standard 0 2.01 December 2007 FIJI card cabling Fiber Network is enabled by the installatio n of one NTRB33 Fiber Junct or Interface (FIJI) card in each Core/Net or Network module (see Figure 95 on page 229 ).
Cabling Common Equipmen t in a Multi Group system Page 229 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 9 5 FIJI card faceplate Optical Cable Man.
Page 230 of 456 Cabling Common Equipm ent in a Multi Group system NN43021-310 Standard 0 2.01 December 2007 The OCMC contains no electronic comp onents and is not powered by the backplane. This card is used primarily in upgrades where the intergroup cable distances vary greatly.
Cabling Common Equipmen t in a Multi Group system Page 231 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Installing the Shelf 0 fibe r optic ring (ascending) To create the Shelf 0 fibe r optic loop, connect the FI JI cards in each Network Shelf 0 in ascending order (Figure 97 on page 232 ) .
Page 232 of 456 Cabling Common Equipm ent in a Multi Group system NN43021-310 Standard 0 2.01 December 2007 Figure 9 7 Shelf 0 fiber o ptic ring on a 4 group machine End of Procedure Installing the Sh.
Cabling Common Equipmen t in a Multi Group system Page 233 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 4 Continue to connect NTRC48xx FIJI Fi ber Ri ng Cables of the appropriate length from the Tx (J1) port to the Rx (J2) port in Shelf 1 of each Network group.
Page 234 of 456 Cabling Common Equipm ent in a Multi Group system NN43021-310 Standard 0 2.01 December 2007 FIJI to FIJI cabling The FIJI cards in Shelf 0 and Shelf 1 of each Network group (except Group 0) must be directly connected with a NTRC47AA FIJI to FIJI Synch Cable cable.
Cabling Common Equipmen t in a Multi Group system Page 235 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Connecting the Clock Controller cables Two Clock Controller car ds are required in each system. These cards synchronize Large System functions.
Page 236 of 456 Cabling Common Equipm ent in a Multi Group system NN43021-310 Standard 0 2.01 December 2007 Figure 1 00 Clock Con troller place ment Connect the cables to the Clock Contro llers as shown in Figure 101 on page 238 . Pr ocedure 37 Connecting the Clock Contr oller cables 1 Connect the Clock to Clock cable: a.
Cabling Common Equipmen t in a Multi Group system Page 237 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning a. At Clock 0: Connect the “J1 Clock” end of a Clock to FIJI cable (NTRC46Ax) to the J1 end of the Clock to Clock cable.
Page 238 of 456 Cabling Common Equipm ent in a Multi Group system NN43021-310 Standard 0 2.01 December 2007 Figure 1 01 Clock Con troller cab le config uration FIJI card Group 0, shelf 0 Dual InterGro.
Page 239 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 260 Cabling network modules and loops Contents This section contains infor mation on the following topics: Network-to-network cabling . . . . . . . .
Page 240 of 456 Cabling network modules an d loops NN43021-310 Standard 0 2.01 December 2007 Network module connections Each multi-group system co ntains be tween tw o and eight Network groups. Group 0 is contained in the Core/Net modul es. Groups 1 through 7 are contained in the Netw ork modules.
Cabling network modules and loops Pag e 241 o f 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 10 2 3PE faceplate connection be tween the Core /Net mo.
Page 242 of 456 Cabling network modules an d loops NN43021-310 Standard 0 2.01 December 2007 Figure 10 3 Network Group 0: Shelf 0 to Sh elf 1 backpla ne connections End of Procedure Connecting Groups 1 through 7: Shelf 0 to Shelf 1 On the back of each Network module bac kplane are five connectors: A, B, C, D and E.
Cabling network modules and loops Pag e 243 o f 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning This connection is NOT ma de for Network Group 0 in the Core/ Net modules.
Page 244 of 456 Cabling network modules an d loops NN43021-310 Standard 0 2.01 December 2007 Figure 1 04 Network Shelf 0 to Shel f 1 backpla ne conn ections (Groups 1 t hrough 7) End of Procedure A B .
Cabling network modules and loops Pag e 245 o f 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Connecting the Network modul es to the Core/Net modules Each Network shelf contains one 3PE car d. These 3PE cards are connected to the Fanout p anel in the b ack of the Core/N et shelves.
Page 246 of 456 Cabling network modules an d loops NN43021-310 Standard 0 2.01 December 2007 Figure 1 06 Core/Net backplane (rear view) GND VCC + 12 GND GND VCC IDE S E C O ND AR Y C HAN N E L FLO P P.
Cabling network modules and loops Pag e 247 o f 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 1 07 3PE Fanout pa nel (rear module vi ew) 553-9529 Ins.
Page 248 of 456 Cabling network modules an d loops NN43021-310 Standard 0 2.01 December 2007 cCNI slot and port assignments Each system core shelf contains a mi nimum of one and a maximum of four cCNI cards. Each cCNI card contains tw o ports to support up to two Network groups.
Cabling network modules and loops Pag e 249 o f 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning cCNI to 3PE Fanout panel cable connections The cCNI slot and port connection s are labeled on the Fanout panel (see Figure 108).
Page 250 of 456 Cabling network modules an d loops NN43021-310 Standard 0 2.01 December 2007 Connecting the 3PE cables to the 3PE fanout panels Two NTND14 cables connect from J3 an d J4 of each 3PE faceplate to the 3PE Fanout panel. See Figure 109 on page 250 .
Cabling network modules and loops Pag e 251 o f 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Refer to Table 32 on page 248 for cCNI port and sl ot assignments. Connect Shelf 0 3PE cards to the Core/Net 0 pa nel; connect Shelf 1 3PE cards to the Core/Net 1 panel.
Page 252 of 456 Cabling network modules an d loops NN43021-310 Standard 0 2.01 December 2007 5 Install the remain ing cables according to the assignments in Table 32 on page 248.
Cabling network modules and loops Pag e 253 o f 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 3 Cable network loops from the fa ceplate connector on the superlo op network card to the backplane for associated controll er cards (see Table 3 3 on page 254 ).
Page 254 of 456 Cabling network modules an d loops NN43021-310 Standard 0 2.01 December 2007 Ta b l e 3 3 NT8D04 network loop con figurations FROM TO Superloop netw ork car d Faceplate connector Contr.
Cabling network modules and loops Pag e 255 o f 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 1 10 NT8D04 Superloo p Network Card network lo ops – .
Page 256 of 456 Cabling network modules an d loops NN43021-310 Standard 0 2.01 December 2007 Cabling a Superloop Networ k Card – multiple columns If the system is configured as a sing le column“Basi c cabling for sin gle-row network connecti ons” on page 252 .
Cabling network modules and loops Pag e 257 o f 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 4 Cable network loops from the facepla te connector on the network card to the I/O panels on the rear of th e Core/Net or Network Mod ule.
Page 258 of 456 Cabling network modules an d loops NN43021-310 Standard 0 2.01 December 2007 8 During syste m software confi gurati on, use the Software Input/Output: Administration (NN43001-611) to enter loop assignments.
Cabling network modules and loops Pag e 259 o f 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 1 12 NT8D04 Superloop Network Card netw ork loops – n.
Page 260 of 456 Cabling network modules an d loops NN43021-310 Standard 0 2.01 December 2007 Figure 1 13 NT8D04 Superloop Network Card netw ork loops – controller card to I/O panel conn ections 553-.
Page 261 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 298 Cabling lines and trunks Contents This section contains infor mation on the following topics: Overview . . . . . . . . . . . . . . . . . . . . . .
Page 262 of 456 Cabling lines and trunks NN43021-310 Standard 0 2.01 December 2007 Figure 1 14 NT8D37 backplane c able designations T able 34 NT8D37 cable connections Backplane slots–shr oud r ows I.
Cabling lines and trunks Page 263 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Media Gateway cabling requirements Media Gateways require th e following:.
Page 264 of 456 Cabling lines and trunks NN43021-310 Standard 0 2.01 December 2007 Pr ocedure 45 Cabling an IPE Module (NT8D37) or Media Gatewa y 1 Select an appropriate number of NE -A25B (or equivalent) cables long enough to run from the I/O panel s on the rear of the module or ba ckplanes of the Media Ga teway or Expander, to the MDF.
Cabling lines and trunks Page 265 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 1 15 NT8D37 IPE Module I/O panels End of Procedure BA FE DC HJ 3 G.
Page 266 of 456 Cabling lines and trunks NN43021-310 Standard 0 2.01 December 2007 Connecting lines and trunks Follow Procedure 46 to connect lin es and trunks. Ensure that wiring is not reversed and is on the proper terminal s. Allow enough slack in the wi ring to allow tracing and to reconnect wires if they break at the terminal.
Cabling lines and trunks Page 267 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning T able 35 Line and trunk pair-termination tab les NT8D37 IPE Module Line .
Page 268 of 456 Cabling lines and trunks NN43021-310 Standard 0 2.01 December 2007 14T/14R 39/14 BK-BR/BK-BR 13 15T/15R 40/15 BK-S/S-BK 14 16T/16R 41/1 6 Y -BL/BL-Y 15 17T/17R 42/17 Y -O/O-Y 16 18T/18.
Cabling lines and trunks Page 269 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning T able 37 NT8D37 IPE Module: NT8D 14 Universal T runk Car d pair-terminat.
Page 270 of 456 Cabling lines and trunks NN43021-310 Standard 0 2.01 December 2007 T able 38 NT8D37 IPE Module: NT8D1 5 E&M T r unk Card 2-w ire pagin g mode pair-terminati ons P air Pin numbers P.
Cabling lines and trunks Page 271 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 3T/3R E/M 38/13 40/15 BK-G/G-BK BK-S/S-BK 3 Note: Each of the f ollowing I/O panel connectors is cabled as sho wn abov e: connectors A, B, C , D , E, F , G, H, K, L, M, N, R, S, T , and U .
Page 272 of 456 Cabling lines and trunks NN43021-310 Standard 0 2.01 December 2007 TA / T B RA/RB E/M ESC/ESCG TA / T B RA/RB EA/EB MA/MB 38/13 39/14 40/15 41/16 BK-G/G-BK BK-BR/BR-BK BK-S/S-BK Y- B L.
Cabling lines and trunks Page 273 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning TA / T B RA/RB E/M ESC/ESCG TA / T B RA/RB EA/EB MA/MB 34/9 35/10 36/11 3.
Page 274 of 456 Cabling lines and trunks NN43021-310 Standard 0 2.01 December 2007 Ta b l e 4 2 NT5K17 Direct Dial Inward T run k connections for NT8D37 I/O panel connectors A, E, K, R (P art 1 of 2) .
Cabling lines and trunks Page 275 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning T6 R6 38 13 BK-G G-BK Slot 0 Sl ot 4 Slot 8 Slot 12 Unit 6 39 14 BK-BR BR.
Page 276 of 456 Cabling lines and trunks NN43021-310 Standard 0 2.01 December 2007 T3 R3 32 7 R-O O-R Slot 1 Sl ot 5 Slot 9 Slot 13 Unit 3 33 8 R-G G-R T4 R4 34 9 R-BR BR-R Slot 1 Sl ot 5 Slot 9 Slot .
Cabling lines and trunks Page 277 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning T2 R2 46 21 V- B L BL-V Slot 0 Sl ot 6 Slot 9 Slot 13 Unit 2 47 22 V- O O.
Page 278 of 456 Cabling lines and trunks NN43021-310 Standard 0 2.01 December 2007 T3 R3 32 7 R-O O-R Slot 2 Sl ot 6 Slot 10 Slot 14 Unit 7 33 8 R-G G-R T4 R4 34 9 R-BR BR-R Slot 3 Sl ot 7 Slot 11 Slo.
Cabling lines and trunks Page 279 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning T2 R2 46 21 V- B L BL-V Slot 3 Sl ot 7 Slot 11 Slot 15 Unit 6 47 22 V- O .
Page 280 of 456 Cabling lines and trunks NN43021-310 Standard 0 2.01 December 2007 T3 R3 32 7 R-O O-R Slot 0 Sl ot 4 Slot 8 Slot 12 Unit 3 33 8 R-G G-R T4 R4 34 9 R-BR BR-R Slot 0 Sl ot 4 Slot 8 Slot .
Cabling lines and trunks Page 281 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning T able 46 NT5K18 Flexible Central Office T runk connections for NT8D37 I/.
Page 282 of 456 Cabling lines and trunks NN43021-310 Standard 0 2.01 December 2007 T7 R7 40 15 BK-S S-BK Slot 1 Sl ot 5 Slot 9 Slot 13 Unit 7 41 16 Y- B L BL-Y T0 R0 42 17 Y- O O-Y Slot 2 Sl ot 6 Slot.
Cabling lines and trunks Page 283 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning T able 47 NT5K18 Flexible Central Office T runk connections for NT8D37 I/.
Page 284 of 456 Cabling lines and trunks NN43021-310 Standard 0 2.01 December 2007 T7 R7 40 15 BK-S S-BK Slot 3 Sl ot 7 Slot 11 Slot 15 Unit 3 41 16 Y- B L BL-Y T0 R0 42 17 Y- O O-Y Slot 3 Sl ot 7 Slo.
Cabling lines and trunks Page 285 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning T able 48 NT5K19 Flexible E&M 2-Wire T ype 1 connections f or NT8D37 .
Page 286 of 456 Cabling lines and trunks NN43021-310 Standard 0 2.01 December 2007 Ta b l e 4 9 NT5K19 E&M 2-Wire T ype 1 connection s f o r NT8D37 I/O panel connector s B, F , L, S Pa i r Pins Pa.
Cabling lines and trunks Page 287 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning T able 50 NT5K19 Flexible E&M 2-Wire T ype 1 trunk connections fo r N.
Page 288 of 456 Cabling lines and trunks NN43021-310 Standard 0 2.01 December 2007 Ta b l e 5 1 NT5K19 Fle xible E&M 2-Wire P aging tr unk connections f or NT8D37 I/O panel connectors A, E, K, R P.
Cabling lines and trunks Page 289 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning T able 52 NT5K19 Fle xible E&M 2-W ire P aging tr unk connections f o.
Page 290 of 456 Cabling lines and trunks NN43021-310 Standard 0 2.01 December 2007 Ta b l e 5 3 NT5K19 Fle xible E&M 2-Wire P aging tr unk connections f or NT8D37 I/O panel c o n n e c t o r sC ,G.
Cabling lines and trunks Page 291 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning T able 54 NT5K19 Flexi ble E&M 2-Wir e Recor ded Ann ouncement tr unk.
Page 292 of 456 Cabling lines and trunks NN43021-310 Standard 0 2.01 December 2007 Ta b l e 5 5 NT5K19 Flexible E&M 2-Wire Recor ded Ann ouncement trunk connecti ons f or NT8D37 I/O panel connecto.
Cabling lines and trunks Page 293 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning T able 56 NT5K19 Flexi ble E&M 2-Wir e Recor ded Ann ouncement tr unk.
Page 294 of 456 Cabling lines and trunks NN43021-310 Standard 0 2.01 December 2007 Ta b l e 5 7 NT5K19 Flexible E&M 4-Wire T ype 1 connections f or NT8D37 I/O panel connectors A, E, K, R Lead desi.
Cabling lines and trunks Page 295 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning T able 58 NT5K19 Flexible E&M 4-Wire T ype 1 connections for NT8D37 I.
Page 296 of 456 Cabling lines and trunks NN43021-310 Standard 0 2.01 December 2007 TA TB 42 17 Y- O O-Y Slot 2 Slot 6 Slot 10 Sl ot 14 Unit 0 RA RB 43 18 Y- G G-Y E M 44 19 Y- B R BR-Y TA TB 46 21 V- .
Cabling lines and trunks Page 297 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning T able 59 NT5K19 Flexible E&M A C15 trunk connections for NT8D37 I/O .
Page 298 of 456 Cabling lines and trunks NN43021-310 Standard 0 2.01 December 2007 Ta b l e 6 0 NT5K19 Flexible E&M A C15 T r unk connections f or NT8D37 I/O panel connectors B, F , L, S Lead desi.
Page 299 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 334 Powering up the system and initial loading Contents This section contains infor mation on the following topics: Overview . . . . . . . . . . . . .
Page 300 of 456 Powering up the system and initial loading NN43021-310 Standard 0 2.01 December 2007 Pr ocedure 47 Installi ng the Securi ty De vice The Security Device fits into t he System Utility ca rd (Fig ure 116 on page 301 ).
Powering up the system and initial loading Page 301 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 1 16 Security Device 553-9149 Side view D ALLAS .
Page 302 of 456 Powering up the system and initial loading NN43021-310 Standard 0 2.01 December 2007 Preparing to power up – AC Follow Procedure 48 to prepare to power up a Large System. Pr ocedure 48 Preparing to power up – A C 1 Set the AC service panel circuit breakers OFF.
Powering up the system and initial loading Page 303 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Pr ocedure 50 Option 2: Har d-wiring th e power con nections (optional) Instead of using the po wer-plug, each co lumn can be hard-wired to the se rvice panel.
Page 304 of 456 Powering up the system and initial loading NN43021-310 Standard 0 2.01 December 2007 3 Set the blower unit switch for Colu mn 0 to ON. On initial power-up, the blower rotates slowly. As the system heats up, the coolin g fans will turn faster.
Powering up the system and initial loading Page 305 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 4 For each non-Core column, verify that: • The main circuit breaker in the pedestal did not trip OFF. • The main blower unit in ea ch column is running.
Page 306 of 456 Powering up the system and initial loading NN43021-310 Standard 0 2.01 December 2007 Preparing to power up – DC Pr ocedure 53 Preparing to power up – DC 1 Set the AC service panel circuit breakers to each rectifier OFF. 2 Remove the DC power distribution fuses or set the distribution circuit breakers OFF.
Powering up the system and initial loading Page 307 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Pr ocedure 54 T urning DC po wer ON 1 Connect each DC rectifier to its associ ated AC outlet and set the breakers in the AC power panel to ON.
Page 308 of 456 Powering up the system and initial loading NN43021-310 Standard 0 2.01 December 2007 8 Make sure the green lights in all the module power supplie s are lit before proceeding to the next colu mn. The red LED for each column remains lit until the system reloads.
Powering up the system and initial loading Page 309 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Pr ocedure 55 Installing the software 1 Check that a terminal is connected to COM1 on Call Server 1. 2 Insert the RMD into the Compact Flash c ard slot.
Page 310 of 456 Powering up the system and initial loading NN43021-310 Standard 0 2.01 December 2007 5 The system attempts to valida te and format the FMD partitions. Th e following format w ill occur only if th e on-board 1 GByte FMD is blank. >Obtaining and checking syst em configuration .
Powering up the system and initial loading Page 311 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning The Fix Media Device on Core 0 is blank. Install cannot continue unless the FMD is partitioned. Note: INSTALL WILL R EBOOT AFTER THIS PROCEDURE AND FIX MEDIA WILL BE EMPTY AFTER YOU PARTITION IT.
Page 312 of 456 Powering up the system and initial loading NN43021-310 Standard 0 2.01 December 2007 Low boundary = 0x137fc1 High boundary = 0x1e8bdf >Fix Media Device repartitio n completed >Formatting FMD ... Mounting msdos fs /boot on / dev/hda1.
Powering up the system and initial loading Page 313 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Label:" " .
Page 314 of 456 Powering up the system and initial loading NN43021-310 Standard 0 2.01 December 2007 Mounting msdos fs /d on /dev /hda3... fdiskDevCreate(/dev/hda3) /dev/hda3: partTablePtr = 0x 12d5ff.
Powering up the system and initial loading Page 315 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 6 The system then enters the Main Menu for keycode au thorization. The system searches for av ailable keyco de files in the “keycode” directory on the RMD.
Page 316 of 456 Powering up the system and initial loading NN43021-310 Standard 0 2.01 December 2007 At this point, either replace the RMD or quit the instal la tion. If you select option “<q> - Quit.”, the syst em requires confirmation. If “ y ” (quit) is selected , the system prints “INST0127 Keycode file is corrupted.
Powering up the system and initial loading Page 317 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 7 Select the keycode to be used on the system.The system validates the selected keycode and displays the software release and machine typ e authorized.
Page 318 of 456 Powering up the system and initial loading NN43021-310 Standard 0 2.01 December 2007 9 If the keycode matches, enter <CR> to continue the installation.
Powering up the system and initial loading Page 319 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 10 Select option “ <b> To install Softwa re, Da tabase, CP-BOOTROM .” The system requires the insertion of the RMD containi ng the software to be installed.
Page 320 of 456 Powering up the system and initial loading NN43021-310 Standard 0 2.01 December 2007 12 The system displays the re lease of the software found o n RMD under the “swload” directory and requ ests confi rmation to continue the installation.
Powering up the system and initial loading Page 321 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 13 Choose yes for the Dependency Lists installation .
Page 322 of 456 Powering up the system and initial loading NN43021-310 Standard 0 2.01 December 2007 14 The Installation Status Summary appears. INST ALLA TION ST A T US SUMMAR Y ---------------------.
Powering up the system and initial loading Page 323 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 15 Enter <CR> to confirm and continue install.ation. Please enter: <CR> -> <y> - Yes, start ins tallation.
Page 324 of 456 Powering up the system and initial loading NN43021-310 Standard 0 2.01 December 2007 16 The PSDL files menu appears. Enter the appropriate choice for the site’s geographic location. 17 Successful installation confirmation appears, enter <C R> to continue.
Powering up the system and initial loading Page 325 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 18 The customer database instal lation from RMD is emp loyed when upgrading CP3, CP4, and CP PII syst ems.
Page 326 of 456 Powering up the system and initial loading NN43021-310 Standard 0 2.01 December 2007 19 Continue with database install ation. Communication Server 1000 So ftware/Database/ BOOTROM RMD Install Tool ============================ ===================== You selected to transfer sin gle database from RMD to FMD on Core 0.
Powering up the system and initial loading Page 327 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning The installation summary screen app ears.
Page 328 of 456 Powering up the system and initial loading NN43021-310 Standard 0 2.01 December 2007 20 Upon return ing to the main install menu, enter q to quit . I N S T A L L M E N U The Software Installation Tool will install or upgrade Succession Enterp rise System Software, Database and the CP-BOOTROM.
Powering up the system and initial loading Page 329 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 21 The system then prompts you to confirm and reboot. Ente r <CR> to quit. Enter <CR> agai n to reboot.
Page 330 of 456 Powering up the system and initial loading NN43021-310 Standard 0 2.01 December 2007 At this point the system sh ould reload and initialize. End of Procedure Testing Core/Net 1 and Core/Net 0 LD 137 modifications The CMDU/MMDU commands a re not applicable to CP PIV.
Powering up the system and initial loading Page 331 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning a. Perform a visual check of the LCDs. b. Test LCDs: 3 Test the System Utility ca rds and the cCNI cards: 4 Test system redundancy: 5 Install the two system monitors.
Page 332 of 456 Powering up the system and initial loading NN43021-310 Standard 0 2.01 December 2007 7 Test the clocks: a. Verify that the clock controller is assigned to the active Core: 8 Verify that the Clock Controll ers are switching correctly: 9 Check applications (CallPi lot, Sym posium, Meridian Mail, and so on.
Powering up the system and initial loading Page 333 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Pr ocedure 58 T esting Core/Net 0 From Core/Net 0, perform these tests: 1 Perform a redundancy sanity test: 2 Check the LCD states: a.
Page 334 of 456 Powering up the system and initial loading NN43021-310 Standard 0 2.01 December 2007 6 Clear the display and minor alarms on both Core s: 7 Test the clocks: a.
Page 335 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 342 Performing acceptance tests Contents This section contains infor mation on the following topics: Acceptance tests . . . . . . . . . . . . . . . .
Page 336 of 456 Performing acceptance tests NN43021-310 Standard 0 2.01 December 2007 See Software Input/Output : Administration (NN43001 -611) for a detailed explanation of software p rompts and the Software Input/ Output: System Messages (NN43001-712) for the meaning of syst em messages and display codes generated during acceptance tests.
Performing acce ptance tests Page 337 o f 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 4 Set the power supply to OFF. Wait until the red column LED lights, then unseat the power supply. • The red column LED should remain lit.
Page 338 of 456 Performing acceptance tests NN43021-310 Standard 0 2.01 December 2007 3 Use a screwdriver to loosen the retaining screws at the front of the blo wer unit (see Figure 117 on pag e 339 ) and pull the unit out un til it is disconnected from the pe destal.
Performing acce ptance tests Page 339 o f 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 1 17 Blower unit re moval Testing the sysload Use Procedure 61 to test the sysload (m anual reload) function.
Page 340 of 456 Performing acceptance tests NN43021-310 Standard 0 2.01 December 2007 On the LCD disp lays on the Cards: • Following the “Selftest Complete” messa ge, watch the LCD for the message “IOP in Slot 17.” • Watch the LCD for the message “Loading Disk OS.
Performing acce ptance tests Page 341 o f 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning %*!&()<>=:,.? READY FOR INPUT 4 Step through the keys on the keyboard one at a time. All keyboard input should be echoed until END is entered.
Page 342 of 456 Performing acceptance tests NN43021-310 Standard 0 2.01 December 2007 7 Set the line transfer switch on th e PFTU to NORMAL, and test the telephones and tru nks connected to the PFTU. The telephones and trunks associated with the PFTU shoul d return to normal opera tion.
Page 343 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 362 Installing earthquake bracing Contents This section contains infor mation on the following topics: Seismic-approved applications . . . . . . . . .
Page 344 of 456 Installin g earthqua ke bracing NN43021-310 Standard 0 2.01 December 2007 Universal equipment modules (UEM) are designed to withstand most earthquakes.
Installing earthquake bracing Page 345 o f 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Selecting the kit To select the applicable bracing an d anchorage k.
Page 346 of 456 Installin g earthqua ke bracing NN43021-310 Standard 0 2.01 December 2007 Next, each column must also be secured to the floor. This is accomplished by installing one o f two available anchor kits. Select the an chor kit by compar ing the site requirements to Table 62 on page 346 .
Installing earthquake bracing Page 347 o f 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning — Flat washer, internal diameter = 0.
Page 348 of 456 Installin g earthqua ke bracing NN43021-310 Standard 0 2.01 December 2007 Pr ocedure 64 Drilling concrete floo rs 1 Using the equipme nt room floor plan mark the position of all of the columns.
Installing earthquake bracing Page 349 o f 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Installing Kit A and Kit B anchor plates The following tools are required to inst all the anchors and the anchor plates: •K i t A — setting tool (Hilti HST 3/4 in.
Page 350 of 456 Installin g earthqua ke bracing NN43021-310 Standard 0 2.01 December 2007 Figure 1 18 Mounting plate installation End of Procedure Pedestal Anchor bolt Shim 553-6071 Mounting plate Ada.
Installing earthquake bracing Page 351 o f 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Pr ocedure 66 Installing Kit B 1 Locate the two mounting plates for ea ch column over the anch or holes. Insert the anchors into the holes and ta p the anchors into place with a mallet.
Page 352 of 456 Installin g earthqua ke bracing NN43021-310 Standard 0 2.01 December 2007 Pr ocedure 67 Installing ear thquake rods 1 Remove the top cap on each column: a. Pull forward on the clips underneath the front edge of each air exhaust grill on the top cap.
Installing earthquake bracing Page 353 o f 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 1 20 Top cap assembly 2 Remove the side pan els on the exterior of each module b y removing the four bolts that secure the panel.
Page 354 of 456 Installin g earthqua ke bracing NN43021-310 Standard 0 2.01 December 2007 3 Install bracing ro ds: • Position each rod in one of the ve rtical slots along the sides of the modules and insert the rods into t he threaded hol es in the pedestal (see Figure 121 on page 355 ).
Installing earthquake bracing Page 355 o f 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 1 21 Installing bracing rods for co lumn support 4 Reinstall the to p cap and grills: • Position each top cap and insta ll the bolts that secure it.
Page 356 of 456 Installin g earthqua ke bracing NN43021-310 Standard 0 2.01 December 2007 6 For a multiple-column system , install NT8D49AA Sp acer Kits between adjacent columns: a. Attach gaskets to both sides in the front section of each spacer (see Figure 122 on page 356 ).
Installing earthquake bracing Page 357 o f 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 1 23 Adding spacers to co lumns 7 Go to “Positioning and leveling the system” on page 357 .
Page 358 of 456 Installin g earthqua ke bracing NN43021-310 Standard 0 2.01 December 2007 3 Loosely install the pedestal mounting hardw are (1/2 in. bolts, lock washer, plain washer, and insulating washer), using the plastic insulating washers. 4 Re-level the column, adding or remo ving shims as needed.
Installing earthquake bracing Page 359 o f 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning NT8D64BF Floor Mounting Kit The NT8D64BF Floor Mountin g Kit provid.
Page 360 of 456 Installin g earthqua ke bracing NN43021-310 Standard 0 2.01 December 2007 5 Abandon the hole if you should hit a reinforcing ba r or the hole breaks through. A minimum of two diagon ally opposite anchors are required fo r this application.
Installing earthquake bracing Page 361 o f 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 1 24 Pedestal mounting flange (rear view) Anchor Metal Washe.
Page 362 of 456 Installin g earthqua ke bracing NN43021-310 Standard 0 2.01 December 2007.
Page 363 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 382 Adding a module to a column Contents This section contains infor mation on the following topics: Overview . . . . . . . . . . . . . . . . . . . .
Page 364 of 456 Adding a module to a column NN43021-310 Standard 0 2.01 December 2007 A module can be added to a column in one of three posi tions. A specific procedure is provided for each situation.
Adding a module to a column Page 365 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Pr ocedure 70 Adding a module to the base of a column 1 Disconnect and remove the NT8D22 System Mo nitor for the column in the rear of the pedestal (do not turn off the blower unit in the front of the pedestals): a.
Page 366 of 456 Adding a module to a column NN43021-310 Standard 0 2.01 December 2007 Figure 1 25 NT7D09CA Pedestal – module power and system monitor connections c. Use a 9/16 in. socke t wrench to re move th e five mounting bolts that secure the module (see Figure 126) and lift it off the column.
Adding a module to a column Page 367 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 1 26 Module mount ing bolts Note: There is an EMI shie ld (it looks like a brass grill) on the top of ea ch pedestal.
Page 368 of 456 Adding a module to a column NN43021-310 Standard 0 2.01 December 2007 5 Connect the power and system mo nitor cables in the module: a. Connect the power connectors to th e pedestal a nd to the module above (see Figure 125 on page 3 66 and Figure 127 on page 369 ).
Adding a module to a column Page 369 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 1 27 Module-to-module po wer and sys tem monitor connecti ons I.
Page 370 of 456 Adding a module to a column NN43021-310 Standard 0 2.01 December 2007 Adding a module between two other modules If conduit or o ther cabling runs throug h modules that are b eing moved, you must tag and disconn ect the cables, pull them out of the modules, and reroute them after all of the modules are repo sitioned.
Adding a module to a column Page 371 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 3 Remove the module that will be above the mo dule being added: a. Disconnect the power connectors betwe en the modules (review Figure 127 on page 369 ).
Page 372 of 456 Adding a module to a column NN43021-310 Standard 0 2.01 December 2007 4 Position and secure modules: a. Locate the positioning gui des on what is now the top module in the column (see Fi gure 129 on page 372 ). Ma ke sure the mo dule being added is facing the same direction as the column.
Adding a module to a column Page 373 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 5 Connect the power and system monitor cables between modules: a. Connect the power connectors between the module being added and the modules above and below it.
Page 374 of 456 Adding a module to a column NN43021-310 Standard 0 2.01 December 2007 Adding a module to the top of a column In a DC-powered system, power to the colum n can remain on during this procedure.
Adding a module to a column Page 375 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 3 Disconnect power connections to the top cap: a. At the top of the rear of the mo dule, di sconnect the orang e power connector from the module power harne ss (see Figure 130 on page 375 ).
Page 376 of 456 Adding a module to a column NN43021-310 Standard 0 2.01 December 2007 Phillips head screwdriver and turn the faste ners 1/4-turn to release or secure the grill (se e Figure 132 on page 376 ). Figure 1 32 UK air exhaust grill removal • Use a 8 mm (5/16 in.
Adding a module to a column Page 377 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 1 33 Top cap assembly Mounting bolts LED 553-3038 Screw for LED.
Page 378 of 456 Adding a module to a column NN43021-310 Standard 0 2.01 December 2007 5 Position and secure the module being add ed: a. Locate the positioning gui des on the module in the column (see Figure 134 on page 378 ). Make sure the module being added i s facing the same direction as the column.
Adding a module to a column Page 379 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 1 35 Module mount ing bolts 6 Connect the power and system monitor cables between modules: a. Connect the power connectors between the module being added and the module below it (see Figure 136 on page 380 ).
Page 380 of 456 Adding a module to a column NN43021-310 Standard 0 2.01 December 2007 Figure 1 36 Module-to-module po wer and sy stem monitor connecti ons I/O safety panel Power connectors between mod.
Adding a module to a column Page 381 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 7 Install the perforated panel an d top cap on the modul e being added: a. Position the perfo rated panel and sli de it slightly to the right (at the rear).
Page 382 of 456 Adding a module to a column NN43021-310 Standard 0 2.01 December 2007 9 Connect the orange power connector to the mo dule power harness. Restore power to the module: • With AC power, se t the ma in circui t breaker t o ON (up ) in the rear of the pedestal.
Page 383 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 448 Installing a Signaling Server Contents This section contains infor mation on the following topics: Introduction . . . . . . . . . . . . . . . . .
Page 384 of 456 Instal ling a Signaling Server NN43021-310 Standard 0 2.01 December 2007 Introduction This chapter contains general instructio ns to install a Nort el CP PM serv er and detailed in structions to install a leg acy Nortel ISP1 100 server.
Installing a Signaling Server Page 385 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning rack mounting, as opposed to two -post rack mounting for the Nortel ISP1 100 server. Readiness checklist Before installing a Signalin g Server in a CS 1000 system, complete the following ch ecklist.
Page 386 of 456 Instal ling a Signaling Server NN43021-310 Standard 0 2.01 December 2007 Ta b l e 6 4 Readiness checklist (P ar t 1 of 2) Have y ou: Read all saf ety instructions in Communicati on Ser.
Installing a Signaling Server Page 387 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Installing the CP PM Sign aling Server hardware The Nortel CP PM server i s a circuit card, and thus is not mounted in a rack.
Page 388 of 456 Instal ling a Signaling Server NN43021-310 Standard 0 2.01 December 2007 This section contains general instructions for installin g the CP PM Signalin g Server circuit cards in CS 1000E and CS 1000M sy stems.
Installing a Signaling Server Page 389 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Connections Connection checklist Before connecting a Signaling Server, ensu re that you have the following materials on-h and.
Page 390 of 456 Instal ling a Signaling Server NN43021-310 Standard 0 2.01 December 2007 CS 1000M system respectively. It also contains instructions for connecting a maintenance ter minal to the No rtel CP PM Signaling Server. The NTDW61BAE5 model of the Nort el CP PM Signaling Server was designed for use in a CS 1000E system.
Installing a Signaling Server Page 391 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 1 39 Faceplates of the Nortel CP PM server.
Page 392 of 456 Instal ling a Signaling Server NN43021-310 Standard 0 2.01 December 2007 Pr ocedure 73 Connecting a Nor tel CP PM Signaling Ser ver Note: Refer to Figure 139 when performing the following procedure. 1 Establish a maintenan ce terminal connection at the back of the shelf of the IPMG.
Installing a Signaling Server Page 393 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 5 Set the COM port on the main tenance terminal as fol lows: • Ter.
Page 394 of 456 Instal ling a Signaling Server NN43021-310 Standard 0 2.01 December 2007 — Insert the end of a longer RJ-45 CAT5 Ethernet cable (not supplied) into the ELAN networ k interface port (.
Installing a Signaling Server Page 395 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Pr ocedure 75 Connecting a CP PM Signaling Server to the ELAN and TL.
Page 396 of 456 Instal ling a Signaling Server NN43021-310 Standard 0 2.01 December 2007 Figure 14 0 IBM X306m Signaling Server (rear view) Note: Refer to Figure 140 when performi ng the following procedure. Pr ocedure 76 Connect ing an I BM X306m Si gnaling Server 1 Connect the Signal ing Server to the TLAN subnet.
Installing a Signaling Server Page 397 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 5 Set the baud rate for the seria l port on the Signali ng Server to 9 60 0 b/ps. See Signaling Server: Installati on and Commissioning (NN43001-312).
Page 398 of 456 Instal ling a Signaling Server NN43021-310 Standard 0 2.01 December 2007 Pr ocedure 77 Connecting an HP DL320-G4 Signaling Server 1 Connect the Signal ing Server to the TLAN subnet. Insert the RJ-45 C AT5 (or better) cable labeled with the number 5 into the port (TLAN network interface) on the back of the Signaling Server.
Installing a Signaling Server Page 399 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Installing the Signa ling Server software Introduction This section provides installatio n pr ocedures for CS 1000 Release 5.
Page 400 of 456 Instal ling a Signaling Server NN43021-310 Standard 0 2.01 December 2007 Installing the software To install software and enter basic system configurat ion parameters on an IBM X306m or HP DL320-G4 Sign aling Server, complete Procedure 78.
Installing a Signaling Server Page 401 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 14 2 Nortel CP PM system BIOS config uration • The VxWorksT.
Page 402 of 456 Instal ling a Signaling Server NN43021-310 Standard 0 2.01 December 2007 Figure 14 3 VxWorks system banner When the Install Tool banner app ears (Figure 144), press <CR> to perfo rm system checks and begin software insta llation.
Installing a Signaling Server Page 403 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 14 4 Install Tool banner screen 3 Press <CR> to perform system checks. If the system has less than 1 Gbyte of RAM, the following error message appears: WARNING: Your system has les s than 1 GB RAM.
Page 404 of 456 Instal ling a Signaling Server NN43021-310 Standard 0 2.01 December 2007 The system verifies the file systems. • If the hard drive of the Signaling Serv er is not pa rtitioned, the file systems verification process fails. Upon failure, the menu in Figure 145 appears.
Installing a Signaling Server Page 405 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 14 6 Date and time • When reinstalling the software on an existing system, the system verifies the file systems.
Page 406 of 456 Instal ling a Signaling Server NN43021-310 Standard 0 2.01 December 2007 Figure 14 7 System Summary CS 1000 Signaling Server S oftware Install Tool (sse-x.
Installing a Signaling Server Page 407 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 14 8 Install Tool Main Menu 4 At the Main Menu (Figure 148), enter a to install Signaling Serve r software. Option a performs options b , c , d , and e .
Page 408 of 456 Instal ling a Signaling Server NN43021-310 Standard 0 2.01 December 2007 The Dependency Lists install ation screen appears (Figure 149). Figure 14 9 Dependency lists installation 5 Press <CR> or enter y to install th e dependency lists.
Installing a Signaling Server Page 409 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 15 0 Installation Status 6 Enter y to sta rt the instal lation. The screen s shown in Figures 151 to 1 57, which sta rt on page 410 , appear.
Page 410 of 456 Instal ling a Signaling Server NN43021-310 Standard 0 2.01 December 2007 Figure 15 1 Installation output Figure 15 2 Software installation success CS 1000 Signaling Server S oftware Install Tool (sse-x.xx.xx ) ========================== ================================= ========== You have selected to insta ll version x.
Installing a Signaling Server Page 411 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 15 3 IP Phone firmware Figure 15 4 Voice Gateway Media Card l.
Page 412 of 456 Instal ling a Signaling Server NN43021-310 Standard 0 2.01 December 2007 Figure 15 5 Restor e IP confi guration 8 Do one of the following: • If you are mig rating a Leade r Signaling.
Installing a Signaling Server Page 413 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 15 6 IP telephony parameter confirmation 9 If you are install.
Page 414 of 456 Instal ling a Signaling Server NN43021-310 Standard 0 2.01 December 2007 Figure 15 7 Signaling Server ro le selection 10 Configure the Signaling Server as Lead er or Follower.
Installing a Signaling Server Page 415 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 15 8 Follower Si gnaling Se rver configurati on • If there .
Page 416 of 456 Instal ling a Signaling Server NN43021-310 Standard 0 2.01 December 2007 11 Configure the application configuratio n for this Signalin g Server.
Installing a Signaling Server Page 417 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 16 1 Network Routing Se rvice (N RS) — stan d-alone Sign aling Serv er 12 Select the Network Routing Servi ce (NRS) to be provided by this Signaling Server.
Page 418 of 456 Instal ling a Signaling Server NN43021-310 Standard 0 2.01 December 2007 Figure 16 2 NRS type — co-reside nt Signaling Server Figure 16 3 NRS type — stand-alone Signaling Server 13 Select the type of NRS to be provid ed by this Signaling Server.
Installing a Signaling Server Page 419 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Depending on whether th e Signaling Serv er is configured as Leader .
Page 420 of 456 Instal ling a Signaling Server NN43021-310 Standard 0 2.01 December 2007 Figure 16 5 Stand-alone Signaling Server configuration 14 Enter the data networking and IP telephony parameters for the Signaling Server, as prompted.
Installing a Signaling Server Page 421 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning TLAN subnet para meters as required.
Page 422 of 456 Instal ling a Signaling Server NN43021-310 Standard 0 2.01 December 2007 — Enter the address of the Primary NRS (optional). — If you did e nter the address of the Primary NRS, enter the address of the Alternate NRS (also optional).
Installing a Signaling Server Page 423 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 16 Enter < CR > or y to confirm the parameters. The example in Figure 168 on page 422 is for a Leader Signa ling Server configured with an Alternate H.
Page 424 of 456 Instal ling a Signaling Server NN43021-310 Standard 0 2.01 December 2007 Figure 16 9 Installation Status Summary 18 Press <CR> to exit to the Main Menu (see Figure 170 on p age 425 ). Enter q at the Main Me nu to quit the i nstallation process.
Installing a Signaling Server Page 425 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 17 0 Install Tool Main Menu Figure 17 1 Quit CS 1000 Signaling Server Softw are Install Tool (sse-x.
Page 426 of 456 Instal ling a Signaling Server NN43021-310 Standard 0 2.01 December 2007 19 Remove the Signaling Server Software CD or the Signaling Server Software CF Card (as appropriate ) from the RMD drive of the Signaling Server and enter q to clo se/terminate the Installati on Tool and reboot the system.
Installing a Signaling Server Page 427 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning – Primary and Alternate NRS IP addresses for this networked system. Refer to IP Peer Networking: Installat ion and Commissioning (NN43001-313) – NRS role, if applicable.
Page 428 of 456 Instal ling a Signaling Server NN43021-310 Standard 0 2.01 December 2007 2 Press <CR> to continue with the configur ation. Th e Restore IP configuration screen appea rs (Figure 173). Figure 17 3 Restor e IP confi guration 3 Enter b at the prompt to bypass the restore of IP conf iguration data.
Installing a Signaling Server Page 429 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 4 Enter the location (loop and shelf) o f the IPMG board. Note: If the IPMG has not been configured yet, the loop and shelf information can be left a t the current value.
Page 430 of 456 Instal ling a Signaling Server NN43021-310 Standard 0 2.01 December 2007 Figure 17 6 Follower Si gnaling Se rver configurati on 7 If there is not a Leader Signa ling Serv er in the IP .
Installing a Signaling Server Page 431 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 8 Configure the application configura tio n for this Signaling Se rver.
Page 432 of 456 Instal ling a Signaling Server NN43021-310 Standard 0 2.01 December 2007 Figure 17 8 Standalone Signal ing Server - NRS Figure 17 9 NRS type — co-reside nt Signaling Server 9 Select the type of NRS to be provid ed by this Signaling Server.
Installing a Signaling Server Page 433 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Depending on whether th e Signaling Server is configured as Leader, .
Page 434 of 456 Instal ling a Signaling Server NN43021-310 Standard 0 2.01 December 2007 Figure 18 2 Stand-alone Signaling Server configuration 10 Enter the data networking and IP telephony parameters for the Signaling Server, as pr ompted.
Installing a Signaling Server Page 435 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 18 3 IP Teleph ony paramete r configuration • Proceed to step 16 on page 423 .
Page 436 of 456 Instal ling a Signaling Server NN43021-310 Standard 0 2.01 December 2007 Depending on wheth er the Signaling Server is configured as Primary, Alternate or Stand-alone, the Pri mary NRS.
Installing a Signaling Server Page 437 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning — If you did e nter the address of the Primary NRS, enter the address of the Alternate NRS (also optional). The Gatekeeper configuration can be updated later using Element Manager.
Page 438 of 456 Instal ling a Signaling Server NN43021-310 Standard 0 2.01 December 2007 12 Press <CR> or enter y to confirm all parameters entered, n to re-enter all param eters, or a le tter a through l to change the value of the corresponding system parameter.
Installing a Signaling Server Page 439 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 18 7 Install tool 13 Enter q to quit the Install Tool. Co nfirm to reboot the system. The Installation Tool quit confirmation screen appea rs (Figure 188).
Page 440 of 456 Instal ling a Signaling Server NN43021-310 Standard 0 2.01 December 2007 Figure 18 8 Installation Tool quit confirmation 14 Enter q to close/terminate the Installation Tool and reboot the Signalin g Server.
Installing a Signaling Server Page 441 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Pr ocedure 80 Adding a F ollower Signaling Server to an IP T elephon.
Page 442 of 456 Instal ling a Signaling Server NN43021-310 Standard 0 2.01 December 2007 Figure 18 9 Node Configuration web page 5 Click Edit next to the node to which t he Follower Signaling Server is to be added. The Edit web page opens, as shown in Figure 190.
Installing a Signaling Server Page 443 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Figure 19 0 Edit web page 6 Click Add next to Signal ing Servers. The section expands to show a list of Signaling Servers and a blank template for enteri ng Signaling Server xxx.
Page 444 of 456 Instal ling a Signaling Server NN43021-310 Standard 0 2.01 December 2007 Figure 19 1 Signaling Server p roperties template 7 Enter the information correspond ing to the Follower Signaling Se rver. The Role field will automa tically revert to Follower once the Follo wer Signaling Server has been added.
Installing a Signaling Server Page 445 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning 8 Click Save and Transfer to transf er the upd ated IP Telephony node information to the other elements of the node.
Page 446 of 456 Instal ling a Signaling Server NN43021-310 Standard 0 2.01 December 2007 Pr ocedure 81 Logging in to the Si gnaling Ser ver Before you begin, make sure the DTE–DTE null modem cabl e (supplied with the Signaling Server) runs be tween the serial p ort on the back of the Signalin g Server and the maintenance te rminal.
Installing a Signaling Server Page 447 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Verifying a successful configuration To ensure that the Signaling Se.
Page 448 of 456 Instal ling a Signaling Server NN43021-310 Standard 0 2.01 December 2007.
Page 449 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning Index Numerics 500/2500-type telephones, 149 A A0367916 Auxiliary –48V Power Supplies, 145, 148 .
Page 450 of 456 Index NN43021-310 Standard 0 2.01 December 2007 C cables and cabling fourth modules, 68 lines and trunks, 261 module additions, 368, 369, 371, 379, 380 network loops, 239 PFTU, 148 rou.
Index Page 451 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning F field wiring kits and terminals PDU connections, 121 floor drilling for anchor bolts, 347 .
Page 452 of 456 Index NN43021-310 Standard 0 2.01 December 2007 Measurement, 66 Meridian 1 Option 61C, 45 Meridian 1 Option 81C, 45 Meridian 1 systems upgrading, 53 MFA150 Modular Power Systems, 93, 9.
Index Page 453 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning NT8D37 IPE Modules backplane slots, 138 cable connections, 262, 265 line pair-termi nation t.
Page 454 of 456 Index NN43021-310 Standard 0 2.01 December 2007 positioning earthquake bracing, 357 equipment, 71 positioning guides fourth modules, 66 module additions, 372, 378 power cables fourth m.
Index Page 455 of 456 Communication Server 1000M and Meridian 1 Large System Installation and Commissioning T telephones, PFTU connections, 149 tests blower units, 337 module power supplies, 336 PFTU,.
Page 456 of 456 Index NN43021-310 Standard 0 2.01 December 2007.
.
F amily Product Manual Contact s Copyright FCC not ice T rad emark s Document numbe r Product re lease Docume nt release Date Pub lish Nor tel Communication Se r v er 1000 Comm unication Server 1000M and Meridian 1 Large System Installation and Commissioning Copyright © 2007 Nor tel Networks.
Een belangrijk punt na aankoop van elk apparaat Nortel 1000M (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Nortel 1000M heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Nortel 1000M vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Nortel 1000M leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Nortel 1000M krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Nortel 1000M bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Nortel 1000M kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Nortel 1000M . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.