http://www.omega.com e-mail: info@omega.com ® U serÕ s Guide DRN-PS-1000 UNIVERSAL SWIT CHING POWER SUPPL Y Compact DIN-Rail 24 V olt U SA MADE IN.
Servicing North America: USA: One Omega Drive, P.O. Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1 TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.
1. General Information and Features 2 2. Safety Considerations 3 3. Installation and Removal 4 3.1 Installation Clearance 5 3.2 Mounting on DIN Rail 6 3.3 Removal of Unit 7 4. Input and Output Connections 8 4.1 Block Diagram 8 4.2 Wiring for 115 Vac - Single Phase 9 4.
The compact DRN power supplies are designed to supply well-regulated 24 volt DC power to sensors, signal conditioners, data acquisition systems and high level logic equipment.
S AFETY C ONSIDERA TIONS 2 3 This device is marked with the international Caution symbol. It is important to read this manual before installing or commissioning this device as it contains important information relating to Safety and EMC (Electromagnetic Compatibility).
If a rail assembly is to be transported, then disconnection, dismounting and separate packing of the power supply is recommended. For units that must be shipped installed on the rail, additional bracing to resist transportation shocks is recommended. Do not attempt to install or connect to the power supply when the mains are energized.
3.1 Installation Clearance Ensure that there is enough room for mounting the power supply unit. There should be a minimum of 1" [25mm] spacing to allow sufficient air circulation for proper cooling.
3.2 Mounting on DIN Rail To install unit onto DIN Rail 1. Tilt unit position mounting guide onto DIN Rail, as shown. 2. Push unit towards DIN Rail and it will snap into place. Figure 3.2 Ñ Mounting on 35mm DIN Rail Figure 3.3 Ñ Mounted on 32mm DIN Rail I NST ALLA TION AND R EMOV AL 3 6 35mm Rail Mounting Guide 1.
3 7 3.3 Removal of Unit The mounting guide can remain on DIN Rail and Power Supply can be removed. 1. While holding mounting guide, push unit upwards and unit will detach from mounting guide. Figure 3.4 Ñ Removal of Unit Figure 3.5 Ñ Unit Removed I NST ALLA TION AND R EMOV AL Mounting Guide CASE T AB MUST BE LOCA TED A T BOTTOM.
4 8 4.1 Block Diagram of Power Supply Figure 4.1 Ñ Block Diagram 4.2 Wiring Warning: Do not turn on the ac power to the power supply unit until you have completed all output connections. Failure to do so may result in injury! This device must only be installed electrically by a specially trained electrician with corresponding qualifications.
4 9 I NPUT AND O UTPUT C ONNECTIONS 4.2 Wiring (Continued) 115Vac - Single phase power wiring Figure 4.2Ñ Wiring for 115Vac - Single Phase Input Power *• USE A SWITCH TO APPLY • +24V POWER TO THE LOAD, • IF THE CAPACITANCE OF • THE LOAD WILL DRAW MORE • THAN 7 AMPS AT TURN ON.
4.3 Wiring (Continued) 230Vac - Two phase power wiring Figure 4.3Ñ Wiring for 230Vac - Two Phase I NPUT AND O UTPUT C ONNECTIONS 4 10 Output Voltage (for shielded wire connections, if necessary) Eart.
S PECIFICA TIONS 5 11 INPUT POWER Input Voltage: 115 - 240Vac ±10% Frequency: 50/60 Hz Current: 0.400A @ 103Vac 0.190A @ 265Vac Overvoltage Protection: 275 Volt Varistor Overcurrent Protection: Fuse .
S PECIFICA TIONS 5 12 GENERAL Operating Temperature: 23¡ to 122¡F(-5¡ to 50¡C) Storage Temperature: -40¡ to 176¡F(-40¡ to 80¡C) Mounting: 32 and 35mm DIN Rail Size: Height: 3.00" (76mm) Width: 0.9" (23mm) Depth: 3.67" (93mm) Weight: 0.
D IMENSIONS 6 13 3.67" (93mm) 3.00" (76mm) 0.9" (23mm).
I NPUT AC VOL T AGE / POWER OUTPUT 7 14 Example: If ambient is 50¼C, maximum wattage is 21W max. for 120-265Vac. If unit is operated at 21W at an input voltage of 100V, the maximum ambient temperature allowed is 40¼C.
.
.
WARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA Warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time.
Where Do I Find Everything I Need for Process Measurement and Control? OM EGAÉOf Course! TEMPERATURE M U Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies M U Wire: Therm.
Een belangrijk punt na aankoop van elk apparaat Omega DRN-PS-1000 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Omega DRN-PS-1000 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Omega DRN-PS-1000 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Omega DRN-PS-1000 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Omega DRN-PS-1000 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Omega DRN-PS-1000 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Omega DRN-PS-1000 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Omega DRN-PS-1000 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.