Gebruiksaanwijzing /service van het product OS643W van de fabrikant Omega
Ga naar pagina of 19
OMEGA OS643W Infrared Thermometer.
OMEGAnet SM On-Line Service http://www.omega.com Internet e-mail info@omega.com For immediate technical or application assistance: USA and Canada: Mexico and Latin America: Sales Service: 1-800-826-63.
1 INTRODUCTION This instrument is a portable easy use 3½ digit, compact-sized digital thermometer designed to use infrared or K-type thermocouple as input. Meter with Backlit LCD, Auto-hold function and auto power off (15 seconds approx.) feature after releasing MEAS button to extend battery life and with analog signal output function.
2 WARNING To avoid damage or burns, do not make temperature measurement in microwave ovens. The symbol on the instrument indicates that the operator must refer to an explanation in this manual.
3 CAUTION • Do not use the unit near any device which generates strong electromag- netic radiation or near a static electrical charge, as these may cause errors. • Do not point the lens at the sun or at any other source of strong light. If you do, the sensor may be damaged.
4 SPECIFICATIONS GENERAL Display: 3½ digit liquid crystal display (LCD) with maximum reading of 1999. Overrange : (OL) or (-OL) is displayed. Low battery indication: the " " is displayed when the battery voltage drops below the operating level.
5 Infrared Radiation ELECTRICAL Temperature Range: 0°F to 500°F, -20°C to 260°C. Display Resolution: 1°F / 1°C. Accuracy: ±3% of reading or ±6°F/3°C, whichever is greater @ 64.4 to 82.4°F (@ 18 to 28°C) ambient operating temperature. Temperature Coefficient: ±0.
6 Spot size increases with distance from the probe tip as shown.
7 K-type thermocouple ELECTRICAL Temperature Range: -58°F to 1999°F, -50°C to 1300°C. Display Resolution: 1°F / 1°C. Accuracy: Accuracy is specified for operating temperatures over the range of 64°F to 83°F (18°C to 28°C), for 1 year, not including thermocouple error.
8 OPERATING INSTRUCTIONS MEAS (MEASURE) Button Depress MEAS button to turn on the meter for measuring temperature. Releasing MEAS button to stop measuring temperature and automatically hold the display reading, the meter turns off automatically after 15 seconds.
OPERATION Infrared Radiation Measurements 1. When the power is off, pressing the MEAS button turns on the power. 2. Use "IR / K" switch to select IR Temperature function. 3. Use " " switch to turn on or turn off the display Back-Light.
10 K-type thermocouple Measurements 1. When the power is off, pressing the MEAS button turns on the power. 2. Use "IR / K" switch to select K Temperature function. 3. Use " " switch to turn on or turn off the display Back-Light. 4.
11 MEASUREMENT CONSIDERATIONS 1. Theory of Measurement Every object emits infrared energy in accordance with its temperature. By measuring the amount of this radiant energy, it is possible to determine the temperature of the emitting object.
12 4. Emissivity All objects emit invisible infrared energy. The amount of energy emitted is proportional to the object's temperature and its ability to emit IR energy. This ability, called emissivity, is based upon the material that the object is made of and its surface finish.
13 MAINTENANCE Battery Replacement Power is supplied by four 1.5V (AAA size) batteries. The " " appears on the LCD display when replacement is needed. To replace the batteries, remove the screw from the back of the meter and lift off the battery cover case.
Substance Thermal Substance Thermal emissivity emissivity Asphalt 0.90 to 0.98 Cloth (black) 0.98 Concrete 0.94 Human skin 0.98 Cement 0.96 Lather 0.75 to 0.80 Sand 0.90 Charcoal (powder) 0.96 Earth 0.92 to 0.96 Lacquer 0.80 to 0.95 W ater 0.92 to 0.96 Lacquer (matt) 0.
W ARRANTY OMEGA warrants this unit to be free of def ects in materials and workmanship and to give satisfactory ser vice for a period of 13 months from date of purchase. OMEGA W arranty adds an additional one (1) month g race per iod to the nor mal one (1) year pr oduct warranty to cov er handling and shipping time .
It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply . OMEGA is constantly pursuing cer tification of its products to the European New Approach Directives . OMEGA will add the CE mark to ev er y appropr iate device upon certification.
Where Do I Find Everything I Need for Process Measurement and Control? OMEGA...Of Course! HEATERS þ Heating Cable þ Cartridge & Strip Heaters þ Immersion & Band Heaters þ Flexible Heaters .
Een belangrijk punt na aankoop van elk apparaat Omega OS643W (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Omega OS643W heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Omega OS643W vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Omega OS643W leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Omega OS643W krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Omega OS643W bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Omega OS643W kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Omega OS643W . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.