Gebruiksaanwijzing /service van het product CJ2 van de fabrikant Omron
Ga naar pagina of 40
Programmable Automation Controllers Introducing the Flagship CJ2 CPU Units, with Built-in Multifunctional EtherNet Port Built-in EtherNet/IP ports T ag based programming Fast processing time Large mem.
2 CJ2 – Omron’ s New Small, Fast & Flexible Modular Flagship P AC, with built-in EtherNet/IP and T ag Based Programming The CJ2 Programmable Automation Controller (P AC) delivers P AC features and capabilities as defined by ARC Advisor y Group in Omron’ s popular , compact modular CJ PLC platform.
3 Key Features and Benefits Large Memor y Capacity – The CPU program memor y capacity has been increased up to 400K Steps, DM has increased up to 800K while Function Block Program, Symbol, Comment Memor y has increased to 3.
4 High-capacity data memor y is in demand to meet the need for quality control for equipment and products and to provide real-time processing and collection of measurement data. Large program capacity is also in demand due to the need for improving program reusability through modularization and structured programming.
5 Automatic User Memor y Recover y Finer memor y production processes have been accompanied by problems such as bit corruption caused by cosmic rays. With the CJ2 CPU Units, corruption in the user program is detected and the program recovered in real time before program execution.
EtherNet/IP CJ2 CPU Programmable T erminal Host application Data links Message communications FTP CX-One HUB CJ2 CPU CJ1-EtherNet/IP Unit Message communications Data links T ranspor t Layer Data Link Physical Layer EtherNet/IP is an industrial network that uses the CIP real-time protocol in the EtherNet application layer .
Host application Support Software CJ1 or CJ2 CPU Unit PLC Programmable T er minal NS Series F A wireless LAN WE70 Data Links FINS Messaging FTP Time Coordination Tag Access Easy Monitoring with Excel P AC Access with Visual Basic/C#.
8 No Need for Memor y Map Control. The CJ2 CPU Units introduce a new feature called tag access, to reduce your TCO (T otal Cost of Ownership) for systems that use Programmable T erminals, multiple P AC’ s, and host applications. T ags allow freedom from memor y maps.
9 The Ease of Changing Designs Makes It Simple to Add or Upgrade Equipment. There is little effect on address changes. Previously , when data was exchanged by address specifi cation and addresses were changed, the program had to be changed at other Controllers and various operations, such as memor y checks, had to be per formed.
10 Connecting Support Software is Now Easier and Safer . Using General-purpose Networks for Support Software Inter face. Connecting to a USB or EtherNet/IP por t is easy , by commercially available cable used around the world. Easy Connection by USB Commercially available cable can be connected to a USB port on the front panel of the CPU Unit.
EtherNet/IP 192.168.250.13 192.168.250.14 192.168.250.15 The P AC name can be easily found by selecting from the list that is displayed. HUB CX-Programmer Online connection PAC name Equipment_A PAC name Equipment_B PAC name Equipment_C HUB Erroneous connection is prevented by checking whether the P AC name matches when connecting online.
Previously (CJ1) CJ2 CJ1 CPU Online editing CJ2 CPU Additional time: Approx. 8 ms Online editing Additional time: Approx. 1 ms FB SFC FB defi nition SFC program FB The size of programs that could be edited online was limited to 4 Ksteps.
13 Greatly Improved Debugging Effi ciency Through Superior Data T racing High-speed, High-capacity Data T racing is now possible. NEW 8 Times More capacity Ample Sampling Data type and T rigger Conditions One, two, or four words of data and comparison conditions can be specifi ed.
D100.05 15 D100 Bit 14 13 12 11 10 9876543210 E0_100.03 D200.00 D100.05 W0.00 TIM 100-ms timer (BCD) 100-ms timer (binary) Timer number Timer number Set value Set value 0001 #10 W0.01 TIMX(550) 0002 #01FF The BCD TIM and binary TIMX instructions can be used together.
NEW Operation status : Published : Input : Output Example Operation start Operation stop d ata [i] Symbol that indirectly specifies the element number Array variable name Start of array Value of eleme.
16 CJ-series CPU Racks ■ A CJ-series CPU Rack consists of a CPU Unit, Power Supply Unit, Configuration Units (Basic I/O Units, Special I/O Units, and CPU Bus Units), and an End Cover . CPU Rack End Cover CJ1W-TER01 (One End Cover is provided as a standard accessory with the CPU Unit.
17 System Configuration CJ-series Expansion Racks ■ A CJ-series Expansion Rack consists of a Power Supply Unit, an I/O Interface Unit, Configuration Units (Basic I/O Units, Special I/O Units, and CPU Bus Units), and an End Cover . Configuration Units: 10 max.
18 External Interface A CJ2H CPU Unit provides three communications ports for external interfaces: a peripheral (USB) port, a s e rial port and an EtherNet/IP port. Pi hl (USB) P Battery Compartment LED Indicators DIP Switch (inside the battery compartment) Memory Card Indicators Indicates the Memory Card status (access and power supply).
19 General Specifications Item CJ2H- CPU64-EIP CPU65-EIP CPU66-EIP CPU67-EIP CPU68-EIP Enclosure Mounted in a panel Grounding Less than 100 Ω CPU Rack Dimensions 90 mm × 65 mm × 80 mm (W × H × D) Weight 280 g or less Current Consumption 5 VDC, 0.
20 Item CJ2H- CPU64-EIP CPU65-EIP CPU66-EIP CPU67-EIP CPU68-EIP User Memory 50K steps 100K steps 150K steps 250K steps 400K steps I/O Bits 2,560 bits Processing Speed Overhead Processing T ime Normal Mode: 200 μs (If tag data links are used with EtherNet/IP , add the following to the above time: 100 μs + Number of transferred words × 0.
21 Item CJ2H- CPU64-EIP CPU65-EIP CPU66-EIP CPU67-EIP CPU68-EIP Programming Languages Ladder Logic (LD), Sequential Function Charts (SFC), Structured T ext (ST), and Instruction Lists (IL) Function Bl.
22 Performance Specifications Item CJ2H- CPU64-EIP CPU65-EIP CPU66-EIP CPU67-EIP CPU68-EIP Communications Logical Ports for Communications Logical Ports 8 ports (Used for SEND, RECV , CMND, PMCR, TXDU, and RXDU instructions.) Extended Logical Ports 64 ports (Used for SEND2, RECV2, CMND2, and PMCR2 instructions.
23 Performance Specifications International Standards • The standards indicated in the “Standards” column are those current for UL, CSA, cULus, cUL, NK, and Lloyd standards and EC Directives as of the end of May 2008.
24 Ordering Information Basic Configuration Units CPU Units CJ2 CPU Units ■ Product name Specifications Current consumption (A) Model Standards I/O capacity/ Mountable Units (Expansion Racks) Program capacity Data memory capacity Function block program, comment, symbol memory 5 V 24 V CJ2 CPU Units 2,560 points/ 40 Units (3 Expansion Racks max.
25 Ordering Information Expansion Racks Select the I/O Control Unit, I/O Interface Unit, Expansion Connecting Cable, and CJ-series Power Supply Unit. CJ-series I/O Control Unit (Mounted on CPU Rac k w.
26 Ordering Information Programming De vices Support Software ■ Product name Specifications Model Standards Number of licenses Media F A Integrated T ool Pac kage CX-One V er. 3. The CX-One is a comprehensive software package that integrates Support Software for OMRON P AC’s , PLC’s and components.
27 Ordering Information Basic I/O Units Input Units ■ Unit classification Product name Specifications No. of wor ds allocated Current consumption (A) Model Standards I/O points Input volta g e and.
28 Ordering Information Output Units ■ Unit classification Product name Specifications No. of wor ds allocated Current consumption (A) Model Standards I/O points Maximum switching capacity Commons.
29 Ordering Information I/O Units ■ Unit classification Product name Specifications No. of wor ds allocated Current consumption (A) Model Standards I/O points Input volta g e, Input current Common.
30 Interrupt Input Units ■ Unit classification Product name Specifications No. of wor ds allocated Current consumption (A) Model Standards I/O points Input volta g e current Commons Input pulse width conditions Max.
31 Special I/O Units and CPU Bus Units Process I/O Units ■ Isolated-type Units with Universal Inputs ● Unit classification Product name Input points Signal range selection Signal range Con version speed (resolution) Accuracy (at ambient temperature of 25°C) External connection No.
32 Ordering Information Isolated-type Resistance Thermometer Input Units ● Unit classification Product name Input points Signal range selection Signal range Con version speed (resolution) Accuracy (at ambient temperature of 25°C) External connection No.
33 Ordering Information Analog Output Units ● Unit classification Product name Output points Signal range selection Signal range Resolution Con version speed Accu- racy (at ambient temper- ature of 25°C) External connection External power supply No.
34 T emperature Control Units ■ Unit classification Product name Specifications No. of unit numbers allocated Current consumption (A) Model Standards No.
35 MECHA TR OLINK-II-compatible P osition Control Units ■ Unit classification Pr oduct name Specifications No. of unit numbers allocated Current consumption (A) Model Standards 5 V 24 V CJ CPU Bus Units MECHA TROLINK-II- compatible Motion Control Units Control commands executed by MECHA TROLINK-II synchronous communications.
36 EtherNet Unit ■ Unit classification Product name Specifications No. of unit numbers allocated Current consumption (A) Model Standards Communications cable Communications functions Max.
37 CompoNet Master Unit ■ Unit classification Product name Specifications No. of unit numbers allocated Current consumption (A) Model Standards Communications functions No. of I/O points per Master Unit 5 V 24 V CJ Special I/O Units CompoNet Master Unit • Remote I/O communications • Message communications Word Slaves: 2,048 max.
38 Dimensions (Unit: mm) Dimensions (Unit: mm ) CJ2H CPU Unit 65 79.8 74.5 2.7 2.7 90 66.2.
39 Checking Current Consumption and Power Consumption After selecting a Power Supply Unit based on considerations such as the power supply voltage, calculate the current and power requirements for each Rack. Condition 1: Current Requirements There are two voltage groups for internal power consumption: 5 V and 24 V .
OMR ON ELECTRONI CS LLC • THE AMERICAS HEADQUARTERS Schaumburg, IL USA • 847.843.7900 • 800.556.6766 • www.omron247.com O MRON CANADA, INC. • HEAD OFFICE Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • www.omron.ca OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE S ã o P aulo, SP, Brasil • 55 .
Een belangrijk punt na aankoop van elk apparaat Omron CJ2 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Omron CJ2 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Omron CJ2 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Omron CJ2 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Omron CJ2 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Omron CJ2 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Omron CJ2 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Omron CJ2 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.