Pelco • 3500 Pelco Way, Clovis • CA 93612-5699 USA • www.pelco.com In North America and Canada: Tel (800) 289-9100 or FAX (800) 289-9150 International Customers: Tel (1-559) 292-1981 or FAX (1-5.
2 Pelco Manual C332M-D (10/98) REVISION HISTOR Y Manual # Date Comments C332M 9/89 Original version. C332M-A 10/91 Rev . A. Re vised to include model PT573-24R/HB. C332M-B 5/95 Rev . B . Section 4.4, Connector Assembly , re vised. Figures 7-9 revised.
Pelco Manual C332M-D (10/98) 3 Please thoroughly familiarize yourself with the information in this manual prior to installation and operation. 1.0 GENERAL 1.1 IMPORT ANT SAFEGUARDS AND W ARNINGS Prior to installation and use of this product, the following W ARNINGS should be obser ved.
4 Pelco Manual C332M-D (10/98) 2.0 DESCRIPTION The PT573R and the PT573-24R are medium duty , indoor/outdoor pan/tilts de- signed f or V330APT retrofit applications. Both units feature rugged worm gear final drives to minimize bac klash and prev ent wind dr ift, and are fully adjustable f or wear .
Pelco Manual C332M-D (10/98) 5 NOTE: When mounting the pan/ tilt outdoors in the inv er ted position (base up), R TV silicone sealant, such as Dow Corning T ype 732 or equivalent, should be applied to the areas indicated in Figure 1.
6 Pelco Manual C332M-D (10/98) REQUIRES EXTERNAL POWER SUPPL Y Ta b le A. Requirements to Wire P ower to P an and Tilt Motors Model Wire Size Maximum Distance "A" Maximum Distance "B" Maximum Distance "B" (A WG) (5 Conductors*) (6 Conductors**) PT573R 20 5,800 ft (1,768 m)*** 1,045 ft (318.
Pelco Manual C332M-D (10/98) 7 Figure 2. Connector Assembly 3.3.1 Mating Connector Assembly To assemb le the mating connectors, ref er to Figure 2 and perform the f ollowing steps. The instructions that follo w apply to all AMP style connectors regardless of pin size or pin number .
8 Pelco Manual C332M-D (10/98) T TO FRAME SCAN CIRCUIT BOARD 4 13 14 11 12 2 10 3 7 P1 VIO RED BLU BRN/W ORG YEL BRN GRN 75W M2 C2 C3 S3 S4 S2 S1 BLU/W C1 M1 AU TO LEFT RIGHT COM UP DOWN COM GND AC NEUT 120 V A C 8 6 5 1 2 3 4 12 15 16 Figure 3.
Pelco Manual C332M-D (10/98) 9 NO TE: CO VER PLA TE IS NOT SHO WN. 3.4 LIMIT STOP ADJUSTMENTS To set pan/tilt limit stops , perf orm the following steps . Ref er to Figure 4. 1. Loosen the pan limit stops. 2. T urn the control unit on. Pan the unit to the right until the desired right pan limit is reached.
10 Pelco Manual C332M-D (10/98) Figure 5. Fr ame Scan Adjustment Location 3.5 FRAME SCAN ADJUSTMENT Fr ame scan duration is set at the factory for appro ximately four seconds . Y ou can adjust the scan duration to operate between tw o and nine seconds.
Pelco Manual C332M-D (10/98) 11 4.0 OPERA TION Refer to the manual for your control equipment for operating the pan/tilt..
12 Pelco Manual C332M-D (10/98) 5.0 TROUBLESHOOTING Some common problems encountered with pan/tilt systems include mis wir ing, over- loading, and not using the units for the correct application. If the pan/tilt unit fails to operate, do the f ollowing: 1.
Pelco Manual C332M-D (10/98) 13 6.0 MAINTENANCE Inspect the pan/tilt unit ev ery six months to ensure trouble-free operation and an e xtended product lif e. Harsh environments and/or continuous motion applications may require more frequent maintenance .
14 Pelco Manual C332M-D (10/98) 7.0 SPECIFICA TIONS GENERAL Construction: Aluminum plate, all internal par ts corrosion protected Dimensions: See Figure 7 Environment: Indoor/outdoor T emperature: -10 ° F to 140 ° F (-23 ° to 60 ° C) W eight Unit: 22 lb (9.
Pelco Manual C332M-D (10/98) 15 Connectors: Amp CPC type, mate supplied Motors: Two-phase induction type, continuous duty, instantaneous reversing Limit Switches: Pan and tilt – 5 amp, 10 million cycle rating (external adjust- ment) Conductor Requirements: 6 (7 if two wires are used for motor common) plus ground, unshielded Figure 7.
16 Pelco Manual C332M-D (10/98) 8.0 WARRANTY AND RETURN INFORMA TION W ARRANTY P elco will repair or replace , without charge, any merchandise prov ed defectiv e in material or wor kman- ship for a period of one year after the date of shipment.
Een belangrijk punt na aankoop van elk apparaat Pelco C332M-D (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Pelco C332M-D heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Pelco C332M-D vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Pelco C332M-D leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Pelco C332M-D krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Pelco C332M-D bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Pelco C332M-D kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Pelco C332M-D . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.