S T AND A LONE A CCESS C ONTROL ECP190 / ECP290 DOOR CONTROLLERS ® Site Coded & Sequentially Number ed Access Passes for Security , Identification & Operational Integrity . ECP190 / ECP290 DOOR CONTROLLERS Site Coded & Sequentially Number ed Access Passes for Security , Identification & Operational Integrity .
2 contents Explanation of Noralsy ® Access P asses 3 General Door Controller Inf ormation 4 ECP 190 Door Controller schematic 5 ECP 290 Door Controller schematic 6 How to use the T elpro ™ progr am.
3 N ORALSY ® A CCESS P ASSES Site Code The number of each and e very Access Pass is visib le. Just b y looking at it, y ou kno w which Access Pass y ou have .
4 ® Noralsy ECP Door Controllers 1 2 3 1 2 4 5 6 3 1 2 3 1 2 4 3 1 2 3 1 2 4 5 3 1 2 3 1 2 3 1 2 1 2 3 1 2 4 3 1 2 4 5 3 1 2 4 5 6 3 1 2 4 5 6 7 3 1 2 4 5 6 7 8 3 1 2 1 2 4 5 6 3 65432 1 654321 1 Standardisation of T erminal Numbering Place Noralsy unit on a flat surface with PCB facing skywards.
12345 6 = 12345 6 32 1 21 123456 32 1 1O N 5 4 3 2 1 1 2 3 4 5 = 32 1 2 1 (—) (+) 5 ® ECP190 Door Controller for 1 n 0 Door/Access Point ■ Capacity 999 Users ELEC/INST/801 Supply 12V DC ± 10% Dimensions 103 L x 106 W x 83 D (6 DIN units) W eight 0.
6 ® ECP290 Door Controller for 2n 0 Doors/Access Points ANTI-P ASSBA CK FEA TURE A V AILABLE Supply 12V DC ± 10% Dimensions 163 L x 106 W x 83 D (10 DIN units) W eight 0.
7 ® Programming Stand-Alone Access Control Systems using TELPRO™ Programmer . MLP3 Proximity MIR Infra-Red MILB Card Reader LB20 Swipe Card ECP190 ECP290 ECP100 ECP200 Access Contr ol Modules, Read.
Important : Each press of a button is confirmed (as r eceived) by the r eader/r eceiver by a single beep. Press the TELPRO ™ buttons gently . Programming using TELPRO ™ as a remote wire-free programmer .
9 PROGRAMMING 08 Example Basic configuration, just do it! Basic configuration, just do it! seconds ECP Door Controller with ACCESS P ASS CONTROL TOP POINTS TO REMEMBER ■ Programming is ef fected via the TELPRO programming keypad. ■ Site Code is always a 5 digit number .
10 *See Tip Wizard on page 13 * STEP 4 Y ou must now inform the Door Controller of the Site Code of the Access Passes supplied. The Site Code is always stored in Slot N o . 01. The Site Code is always a 5 digit number . Check the Access Pass Information Sheet delivered with the Access Passes.
11 After a beep enter on the TELPRO: A sharp beep confirms that you have correctly deleted Holder Number 074. Pr ogramming mode beep - every 4 seconds - resumes. Example C: V alidation of 1n o . Access Pass Y ou have just received the additional Access Pass order ed for Alan Jones who had lost his earlier in the week.
12 ECP290 D OOR C ONTROLLER FOR 2 D OORS – I MPORT ANT I NFORMA TION FLICKING PROGRAMMING SWITCH SW1. The access control readers on both doors will star t to beep ev er y 4 seconds indicating programming mode status . Only 1 n o . access point (door) can be programmed at a time .
13 Mode 4 - Dual Security , Access Pass + K e ypad Code 00 4 00508 = Set-Up , Mode 4 È Rela y output time in seconds User required to present a valid access pass and then enter a v alid code or vice versa in order to gain access . A maximum of 27n o .
14 ® ® Noralsy® ECP Door Controller 32 1 2 1 32 1 654321 65432 1 1 2 4 5 6 3 6 5 3 2 1 4 32 1 + 21 32 1 (—) (+) Fail Safe Locking ECP190 Door Controller ECP190 Door Controller ECP190 Door Controller Automation Control / V olt Free Entrance/Exit Access point requiring access contr ol on both sides of the door , gate or barrier .
15 ® ® 32 1 (–) (+) 21 32 1 Locking ECP190 Door Controller Noralsy® ECP Door Controller DIN Rail Mounting W all Mounting DIN Rail ELEC/INST/805 ELEC/INST/806 ELEC/INST/807.
® ® 16 Noralsy® DIN Rail Power Supplies ELEC/INST/808 ELEC/INST/809 ELEC/INST/810 ELEC/INST/811 ARE121 12V AC/DC 1 AMP MAXIMUM OUTPUT ARE122 12V DC 2 AMP MAXIMUM OUTPUT ARS122 12V DC .
17 ® Noralsy® Powering ECP Door Controller(s) using Noralsy® DIN Rail Power Supply Units ELEC/INST/812 ARE121 + ECP190 ARE122 + ECP290 ELEC/INST/812A.
18 ECP190 DOOR CONTROLLER with KEYP AD ACCESS CODE CONTROL TOP POINTS TO REMEMBER ■ Programming is ef fected directly via the keypad. ■ Master Code (Programming Access Code) is always a 5 digit number . ■ Master Code is always stored in Slot N o .
19 After a beep enter on the keypad: A sharp beep confirms that you have deleted Alan’ s code. Programming mode beep - every 4 seconds - resumes. After a beep enter on the keypad: A sharp beep confirms that you have deleted Alex’ s code. Programming mode beep - every 4 seconds - resumes.
N.A.C.D. Limited Unit 10, Avebury Court, Mark Road, Hemel Hempstead, Her ts HP2 7T A. TEL: 01442 211848 F AX: 01442 212776 EMAIL: sales@nacd.co.uk WEB: www.nacd.co.uk Our policy is one of continuous product impr ovement, we reserve the right to change specifications and prices without notice.
Een belangrijk punt na aankoop van elk apparaat Pelco ECP190 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Pelco ECP190 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Pelco ECP190 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Pelco ECP190 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Pelco ECP190 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Pelco ECP190 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Pelco ECP190 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Pelco ECP190 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.