NL
Philips logo
Officiële handleiding

Philips BGD602

6 pagina's·21 KB·Stereoversterker·PDF·EN
Philips BGD602
Inhoudsopgave 7 secties FEATURES · DESCRIPTION · PINNING · QUICK REFERENCE DATA · … TonenVerbergen
Page 1 of the Philips BGD602 user manual — DISCRETE SEMICONDUCTORS
Pagina 1 · klik om te vergroten
Pagina 1

DISCRETE SEMICONDUCTORS

DATA SHEET

BGD602 CATV amplifier module

Product specification File under Discrete Semiconductors, SC16

Philips Semiconductors

Page 2 of the Philips BGD602 user manual — QUICK REFERENCE DATA
Pagina 2 · klik om te vergroten
Pagina 2

FEATURES

PINNING - SOT115J

  • Excellent linearity

PIN DESCRIPTION

  • Extremely low noise
  • Silicon nitride passivation

7 8 9 2 3 5 1

  • Rugged construction
  • Gold metallization ensures excellent reliability.

5 +VB 7 common

Fig.1 Simplified outline.

DESCRIPTION

Hybrid high dynamic range amplifier module designed for applications in CATV systems with a bandwidth of 40 to 600 MHz operating with a voltage supply of 24 V (DC).

QUICK REFERENCE DATA

SYMBOLPARAMETERCONDITIONSMIN.MAX.UNIT G ppower gainf = 50 MHz1819dB f = 600 MHz19−dB I tottotal current consumption (DC)V = 24 V B−435mA

LIMITING VALUES In accordance with the Absolute Maximum Rating System (IEC 134).

SYMBOLPARAMETERMIN.MAX.UNIT V iRF input voltage−65dBmV T stgstorage temperature−40+100°C T mboperating mounting base temperature−20+100°C
Show 7 more labels / short text on this page
1 input · fpage · 2 common · 3 common · Side view MSA319 · 8 common · 9 output
Page 3 of the Philips BGD602 user manual — CHARACTERISTICS
Pagina 3 · klik om te vergroten
Pagina 3

CHARACTERISTICS Bandwidth 40 to 600 MHz; VB = 24 V; Tmb = 35 °C; ZS = ZL = 75 Ω.

SYMBOLPARAMETERCONDITIONSMIN.MAX.UNIT G ppower gainf = 50 MHz1819dB f = 600 MHz19−dB SLslope cable equivalentf = 40 to 600 MHz0.22.2dB FLflatness of frequency responsef = 40 to 600 MHz−±0.3dB S 11input return lossesf = 40 to 80 MHz20−dB f = 80 to 160 MHz19−dB f = 160 to 600 MHz18−dB S 22output return lossesf = 40 to 80 MHz20−dB f = 80 to 160 MHz19−dB f = 160 to 600 MHz18−dB S 21phase responsef = 50 MHz−45+45deg CTBcomposite triple beat85 channels flat; V = 44 dBmV; o measured at 595.25 MHz−−62dB X modcross modulation85 channels flat; V = 44 dBmV; o measured at 55.25 MHz−−66dB CSOcomposite second order distortion85 channels flat; V = 44 dBmV; o measured at 596.5 MHz−−60dB d 2second order distortionnote 1−−70dB V ooutput voltaged = −60 dB; note 2 im63−dBmV Fnoise figuref = 600 MHz−8dB I tottotal current consumption (DC)note 3−435mA
1. f p = 55.25 MHz; V p = 44 dBmV; f q = 541.25 MHz; V q = 44 dBmV; measured at f p + f q = 596.5 MHz.
2. Measured according to DIN45004B: f p = 590.25 MHz; V p = V o ; f q = 597.25 MHz; V q = V o − 6 dB; f r = 599.25 MHz; V r = V o − 6 dB; measured at f p + f q − f r = 588.25 MHz.
3. The module normally operates at V B = 24 V, but is able to withstand supply transients up to 30 V.
Page 4 of the Philips BGD602 user manual — CHARACTERISTICS
Pagina 4 · klik om te vergroten
Pagina 4

CHARACTERISTICS Bandwidth 40 to 550 MHz; VB = 24 V; Tmb = 35 °C; ZS = ZL = 75 Ω.

SYMBOLPARAMETERCONDITIONSMIN.MAX.UNIT G ppower gainf = 50 MHz1819dB f = 550 MHz18.8−dB SLslope cable equivalentf = 40 to 550 MHz0.22.2dB FLflatness of frequency responsef = 40 to 550 MHz−±0.3dB S 11input return lossesf = 40 to 80 MHz20−dB f = 80 to 160 MHz19−dB f = 160 to 550 MHz18−dB S 22output return lossesf = 40 to 80 MHz20−dB f = 80 to 160 MHz19−dB f = 160 to 550 MHz18−dB S 21phase responsef = 50 MHz−45+45deg CTBcomposite triple beat77 channels flat; V = 44 dBmV; o measured at 547.25 MHz−−66dB X modcross modulation77 channels flat; V = 44 dBmV; o measured at 55.25 MHz−−68dB CSOcomposite second order distortion77 channels flat; V = 44 dBmV; o measured at 548.5 MHz−−62dB d 2second order distortionnote 1−−72dB V ooutput voltaged = −60 dB; note 2 im64−dBmV Fnoise figuref = 550 MHz−7.5dB I tottotal current consumption (DC)note 3−435mA
1. f p = 55.25 MHz; V p = 44 dBmV; f q = 493.25 MHz; V q = 44 dBmV; measured at f p + f q = 548.5 MHz.
2. Measured according to DIN45004B: f p = 540.25 MHz; V p = V o ; f q = 547.25 MHz; V q = V o − 6 dB; f r = 549.25 MHz; V r = V o − 6 dB; measured at f p + f q − f r = 538.25 MHz.
3. The module normally operates at V B = 24 V, but is able to withstand supply transients up to 30 V.
Page 5 of the Philips BGD602 user manual — CHARACTERISTICS
Pagina 5 · klik om te vergroten
Pagina 5

CHARACTERISTICS Bandwidth 40 to 450 MHz; VB = 24 V; Tmb = 35 °C; ZS = ZL = 75 Ω.

SYMBOLPARAMETERCONDITIONSMIN.MAX.UNIT G ppower gainf = 50 MHz1819dB f = 450 MHz18.6−dB SLslope cable equivalentf = 40 to 450 MHz0.21.8dB FLflatness of frequency responsef = 40 to 450 MHz−±0.3dB S 11input return lossesf = 40 to 80 MHz20−dB f = 80 to 160 MHz19−dB f = 160 to 450 MHz18−dB S 22output return lossesf = 40 to 80 MHz20−dB f = 80 to 160 MHz19−dB f = 160 to 450 MHz18−dB S 21phase responsef = 50 MHz−45+45deg CTBcomposite triple beat60 channels flat; V = 46 dBmV; o measured at 445.25 MHz−−67dB X modcross modulation60 channels flat; V = 46 dBmV; o measured at 55.25 MHz−−66dB CSOcomposite second order distortion60 channels flat; V = 46 dBmV o measured at 446.5 MHz−−60dB d 2second order distortionnote 1−−75dB V ooutput voltaged = −60 dB; note 2 im67−dBmV Fnoise figuref = 450 MHz−7dB I tottotal current consumption (DC)note 3−435mA
1. f p = 55.25 MHz; V p = 46 dBmV; f q = 391.25 MHz; V q = 46 dBmV; measured at f p + f q = 446.5 MHz.
2. Measured according to DIN45004B: f p = 440.25 MHz; V p = V o ; f q = 447.25 MHz; V q = V o − 6 dB; f r = 449.25 MHz; V r = V o − 6 dB; measured at f p + f q − f r = 438.25 MHz.
3. The module normally operates at V B = 24 V, but is able to withstand supply transients up to 30 V.
Page 6 of the Philips BGD602 user manual — LIFE SUPPORT APPLICATIONS
Pagina 6 · klik om te vergroten
Pagina 6

DEFINITIONS

Data sheet status Objective specificationThis data sheet contains target or goal specifications for product development. Preliminary specificationThis data sheet contains preliminary data; supplementary data may be published later. Product specificationThis data sheet contains final product specifications. Limiting values Limiting values given are in accordance with the Absolute Maximum Rating System (IEC 134). Stress above one or more of the limiting values may cause permanent damage to the device. These are stress ratings only and operation of the device at these or at any other conditions above those given in the Characteristics sections of the specification is not implied. Exposure to limiting values for extended periods may affect device reliability. Application information Where application information is given, it is advisory and does not form part of the specification.

LIFE SUPPORT APPLICATIONS

These products are not designed for use in life support appliances, devices, or systems where malfunction of these products can reasonably be expected to result in personal injury. Philips customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Philips for any damages resulting from such improper use or sale.

Vraag stellen over de Philips BGD602

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Philips BGD602

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Philips BGD602 handleiding-pdf

6 pagina's·21 KB·Stereoversterker·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%