DISCRETE SEMICONDUCTORS

DATA SHEET

M3D188

BGY148A; BGY148B HF amplifier modules

Product specification Supersedes data of 1997 Jul 14

book, halfpage

Page 2 of the Philips BGY148A user manual — Note
Pagina 2 · klik om te vergroten
Pagina 2

FEATURES

PINNING - SOT421A

  • Single 6 V nominal supply voltage
PINDESCRIPTION 1RF input 2V C 3V S 4RF output Flangeground
  • 3 W output power
  • Easy control of output power by DC voltage
  • Silicon bipolar technology
  • Standby current less than 100 µ A.

APPLICATIONS

  • Portable communication equipment operating in the 400 to 440 MHz and 430 to 488 MHz frequency ranges respectively.

DESCRIPTION

The BGY148A and BGY148B are three-stage UHF amplifier modules in a SOT421A package. Each module consists of three NPN silicon planar transistor dies mounted together with matching and bias circuit components on a metallized ceramic substrate. The modules produce an output power of 3 W into a load of 50 Ω with an RF drive power of 10 mW.

1 2 3 4

MSA483

Fig.1 Simplified outline (SOT421A).

QUICK REFERENCE DATA RF performance at Tmb = 25 °C.

TYPEMODE OF OPERATIONf (MHz)V S (V)P L (W)G p (dB)η (%)Z ; Z S L (Ω) BGY148ACW400 to 4406≥3≥24.8typ. 5350 BGY148BCW430 to 4886≥3≥24.8typ. 5350

LIMITING VALUES In accordance with the Absolute Maximum Rating System (IEC 134).

SYMBOLPARAMETERMIN.MAX.UNIT V SDC supply voltage−8.5V V CDC control voltage−4V P Dinput drive power−20mW P Lload power−3.5W T stgstorage temperature−40+100°C T mboperating mounting-base temperature; note1−30+100°C

Note

1. In order to control the mounting-base temperature, proper heatsinking of the underside of the device is required. It is therefore advisable that the device is mounted on a printed-circuit board with metallized through holes.

Top view

Page 3 of the Philips BGY148A user manual — MDA207
Pagina 3 · klik om te vergroten
Pagina 3

CHARACTERISTICS ZS = ZL = 50 Ω; PD = 10 mW; VS = 6 V; VC ≤3.5 V; Tmb = 25 °C; unless otherwise specified.

SYMBOLPARAMETERCONDITIONSMIN.TYP.MAX.UNIT ffrequency range BGY148A BGY148B400 430− −440 488MHz MHz I Qtotal quiescent currentV = 0; P = 0 C D−−100µA I Ccontrol currentadjust V for P = 3 W C L−−500µA P Lload power3−−W G ppower gainadjust V for P = 3 W C L24.8−−dB ηefficiencyadjust V for P = 3 W C L4653−% H 2second harmonicadjust V for P = 3 W C L−−−38dBc H 3third harmonicadjust V for P = 3 W C L−−−38dBc VSWR ininput VSWRadjust V for P = 3 W C L−−3 : 1 control rangeV = 0 to 3.5 V C10−−dB stabilityP = 5 to 20 mW; V = 5 to 8.5 V; D S P ≤3.5 W; L VSWR ≤4 : 1 through all phases−−−60dBc ruggednessV = 8.5 V; adjust V for P = 3.5 W; S C L VSWR ≤4 : 1 through all phasesno degradation

MDA207

VSWR = 1:1

VSWR = 3:1

Tmb (oC) 20 40 60 80

VS = 8.5 V.

Fig.2 Load power derating curves.

Page 4 of the Philips BGY148A user manual — CHARACTERISTICS
Pagina 4 · klik om te vergroten
Pagina 4

η (%) 440 MHz

ZS = ZL = 50 Ω; PD = 10 mW; VS = 6 V; Tmb = 25 °C.

ZS = ZL = 50 Ω; PD = 10 mW; VS = 6 V; Tmb = 25 °C.

Fig.3 Load power as a function of control voltage; BGY148A; typical values.

Fig.4 Efficiency as a function of load power; BGY148A; typical values.

ZS = ZL = 50 Ω; PD = 10 mW; VS = 6 V; VC = 3.5 V; Tmb = 25 °C.

ZS = ZL = 50 Ω; PD = 10 mW; VS = 6 V; PL = 3 W; Tmb = 25 °C.

Fig.5 Load power as a function of frequency; BGY148A; typical values.

Fig.6 Efficiency as a function of frequency; BGY148A; typical values.

Show 4 more labels / short text on this page
η (%) · 380 400 · 460 440 · 460 440
Page 5 of the Philips BGY148A user manual — MDA206
Pagina 5 · klik om te vergroten
Pagina 5

H2, H3

H3

H2

ZS = ZL = 50 Ω; PD = 10 mW; VS = 6 V; PL = 3 W; Tmb = 25 °C.

ZS = ZL = 50 Ω; PD = 2 mW; VS = 4.8 V; PL = 3 W; Tmb = 25 °C.

Fig.7 Control voltage and input VSWR as functions of frequency; BGY148A; typical values.

Fig.8 Harmonics as a function of frequency; BGY148A; typical values.

MDA206

Tmb (oC) 0 25 50 75

ZS = ZL = 50 Ω; PD = 2 mW; VS = 4.8 V; Tmb = 25 °C.

Fig.9 Load power as a function of mounting base temperature; BGY148A; typical values.

Show 8 more labels / short text on this page
−30 · VSWRin · (dBc) · −40 · VSWRin · −50 · −60 · −25 100
Page 6 of the Philips BGY148A user manual — Fig.12 Load power as a function of frequency;
Pagina 6 · klik om te vergroten
Pagina 6

ZS = ZL = 50 Ω; PD = 10 mW; VS = 6 V; Tmb = 25 °C.

ZS = ZL = 50 Ω; PD = 10 mW; VS = 6 V; Tmb = 25 °C.

Fig.10 Load power as a function of control voltage;

Fig.11 Efficiency as a function of load power;

BGY148B; typical values.

BGY148B; typical values.

ZS = ZL = 50 Ω; PD = 10 mW; VS = 6 V; VC = 3.5 V; Tmb = 25 °C.

ZS = ZL = 50 Ω; PD = 10 mW; VS = 6 V; PL = 3 W; Tmb = 25 °C.

Fig.12 Load power as a function of frequency;

Fig.13 Efficiency as a function of frequency;

BGY148B; typical values.

BGY148B; typical values.

Show 5 more labels / short text on this page
η (%) · η (%) · 420 440 · 500 480 · 500 480
Page 7 of the Philips BGY148A user manual — Fig.16 Load power as a function of mounting base
Pagina 7 · klik om te vergroten
Pagina 7

H2, H3

H2

H3

ZS = ZL = 50 Ω; PD = 10 mW; VS = 6 V; PL = 3 W; Tmb = 25 °C.

ZS = ZL = 50 Ω; PD = 2 mW; VS = 4.8 V; PL = 3 W; Tmb = 25 °C.

Fig.14 Control voltage and input VSWR as functions

Fig.15 Harmonics as a function of frequency;

of frequency; BGY148B; typical values.

BGY148B; typical values.

MDA205

Tmb (oC) 0 25 50 75

ZS = ZL = 50 Ω; PD = 2 mW; VS = 4.8 V; Tmb = 25 °C.

Fig.16 Load power as a function of mounting base

temperature; BGY148B; typical values.

Show 9 more labels / short text on this page
−30 · VSWRin · (dBc) · −40 · −50 · VSWRin · −60 · −70 · −25 100
Page 8 of the Philips BGY148A user manual — Cleaning
Pagina 8 · klik om te vergroten
Pagina 8

SOLDERING

The indicated temperatures are those at the solder interfaces.

MGM159

Advised solder types are types with a liquidus less than or equal to 210 °C.

T ( ° C)

Solder dots or solder prints must be large enough to wet the contact areas.

Soldering can be carried out using a conveyor oven, a hot air oven, an infrared oven or a combination of these ovens. A double reflow process is permitted.

Hand soldering must be avoided because the soldering iron tip can exceed the maximum permitted temperature of 250 °C and damage the module.

The maximum allowed temperature is 250 °C for 5 seconds.

0 1 5 2 3 4

The maximum ramp-up is 10 °C per second.

The maximum cool-down is 5 °C per second.

Fig.17 Recommended reflow temperature profile.

Cleaning

The following fluids may be used for cleaning:

  • Alcohol
  • Bio-Act (Terpene Hydrocarbon)
  • Acetone.

Ultrasonic cleaning should not be used since this can cause serious damage to the product.

t (min)

Page 9 of the Philips BGY148A user manual — SOLDERING
Pagina 9 · klik om te vergroten
Pagina 9
Philips BGY148A — SOLDERING diagram (page 9)
Afb. 1
Page 10 of the Philips BGY148A user manual — U
Pagina 10 · klik om te vergroten
Pagina 10

PACKAGE OUTLINE

Ceramic single-ended flat package; 4 in-line leads SOT421A

U

D

A

Z

E

U1

L Q

1 2 3 4

0 5 10 mm

DIMENSIONS (mm are the original dimensions)

UNITAbcDdEee1LQUU1wyZ mm3.0 2.60.56 0.460.30 0.2022.1 21.72.4 2.013.4 13.05.087.620.7 0.33.4 3.022.4 22.08.2 7.80.250.150.25 0.05
OUTLINE VERSIONREFERENCESEUROPEAN PROJECTIONISSUE DATE IECJEDECEIAJ SOT421A97-06-20
Show 7 more labels / short text on this page
y · b · w M · d · e e · e1 · scale
Page 11 of the Philips BGY148A user manual — LIFE SUPPORT APPLICATIONS
Pagina 11 · klik om te vergroten
Pagina 11

DEFINITIONS

Data sheet status Objective specificationThis data sheet contains target or goal specifications for product development. Preliminary specificationThis data sheet contains preliminary data; supplementary data may be published later. Product specificationThis data sheet contains final product specifications. Limiting values Limiting values given are in accordance with the Absolute Maximum Rating System (IEC 134). Stress above one or more of the limiting values may cause permanent damage to the device. These are stress ratings only and operation of the device at these or at any other conditions above those given in the Characteristics sections of the specification is not implied. Exposure to limiting values for extended periods may affect device reliability. Application information Where application information is given, it is advisory and does not form part of the specification.

LIFE SUPPORT APPLICATIONS

These products are not designed for use in life support appliances, devices, or systems where malfunction of these products can reasonably be expected to result in personal injury. Philips customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Philips for any damages resulting from such improper use or sale.

Page 12 of the Philips BGY148A user manual — Philips Semiconductors – a worldwide company
Pagina 12 · klik om te vergroten
Pagina 12

Philips Semiconductors – a worldwide company

Argentina: see South America Australia: 34 Waterloo Road, NORTH RYDE, NSW 2113, Tel. +61 2 9805 4455, Fax. +61 2 9805 4466 Austria: Computerstr. 6, A-1101 WIEN, P.O. Box 213, Tel. +43 160 1010, Fax. +43 160 101 1210 Belarus: Hotel Minsk Business Center, Bld. 3, r. 1211, Volodarski Str. 6, 220050 MINSK, Tel. +375 172 200 733, Fax. +375 172 200 773 Belgium: see The Netherlands Brazil: see South America Bulgaria: Philips Bulgaria Ltd., Energoproject, 15th floor, 51 James Bourchier Blvd., 1407 SOFIA, Tel. +359 2 689 211, Fax. +359 2 689 102 Canada: PHILIPS SEMICONDUCTORS/COMPONENTS, Tel. +1 800 234 7381 China/Hong Kong: 501 Hong Kong Industrial Technology Centre, 72 Tat Chee Avenue, Kowloon Tong, HONG KONG, Tel. +852 2319 7888, Fax. +852 2319 7700 Colombia: see South America Czech Republic: see Austria Denmark: Prags Boulevard 80, PB 1919, DK-2300 COPENHAGEN S, Tel. +45 32 88 2636, Fax. +45 31 57 0044 Finland: Sinikalliontie 3, FIN-02630 ESPOO, Tel. +358 9 615800, Fax. +358 9 61580920 France: 51 Rue Carnot, BP317, 92156 SURESNES Cedex, Tel. +33 1 40 99 6161, Fax. +33 1 40 99 6427 Germany: Hammerbrookstraße 69, D-20097 HAMBURG, Tel. +49 40 23 53 60, Fax. +49 40 23 536 300 Greece: No. 15, 25th March Street, GR 17778 TAVROS/ATHENS, Tel. +30 1 4894 339/239, Fax. +30 1 4814 240 Hungary: see Austria India: Philips INDIA Ltd, Band Box Building, 2nd floor, 254-D, Dr. Annie Besant Road, Worli, MUMBAI 400 025, Tel. +91 22 493 8541, Fax. +91 22 493 0966 Indonesia: PT Philips Development Corporation, Semiconductors Division, Gedung Philips, Jl. Buncit Raya Kav.99-100, JAKARTA 12510, Tel. +62 21 794 0040 ext. 2501, Fax. +62 21 794 0080 Ireland: Newstead, Clonskeagh, DUBLIN 14, Tel. +353 1 7640 000, Fax. +353 1 7640 200 Israel: RAPAC Electronics, 7 Kehilat Saloniki St, PO Box 18053, TEL AVIV 61180, Tel. +972 3 645 0444, Fax. +972 3 649 1007 Italy: PHILIPS SEMICONDUCTORS, Piazza IV Novembre 3, 20124 MILANO, Tel. +39 2 6752 2531, Fax. +39 2 6752 2557 Japan: Philips Bldg 13-37, Kohnan 2-chome, Minato-ku, TOKYO 108-8507, Tel. +81 3 3740 5130, Fax. +81 3 3740 5077 Korea: Philips House, 260-199 Itaewon-dong, Yongsan-ku, SEOUL, Tel. +82 2 709 1412, Fax. +82 2 709 1415 Malaysia: No. 76 Jalan Universiti, 46200 PETALING JAYA, SELANGOR, Tel. +60 3 750 5214, Fax. +60 3 757 4880 Mexico: 5900 Gateway East, Suite 200, EL PASO, TEXAS 79905, Tel. +9-5 800 234 7381

Middle East: see Italy Netherlands: Postbus 90050, 5600 PB EINDHOVEN, Bldg. VB, Tel. +31 40 27 82785, Fax. +31 40 27 88399 New Zealand: 2 Wagener Place, C.P.O. Box 1041, AUCKLAND, Tel. +64 9 849 4160, Fax. +64 9 849 7811 Norway: Box 1, Manglerud 0612, OSLO, Tel. +47 22 74 8000, Fax. +47 22 74 8341 Pakistan: see Singapore Philippines: Philips Semiconductors Philippines Inc., 106 Valero St. Salcedo Village, P.O. Box 2108 MCC, MAKATI, Metro MANILA, Tel. +63 2 816 6380, Fax. +63 2 817 3474 Poland: Ul. Lukiska 10, PL 04-123 WARSZAWA, Tel. +48 22 612 2831, Fax. +48 22 612 2327 Portugal: see Spain Romania: see Italy Russia: Philips Russia, Ul. Usatcheva 35A, 119048 MOSCOW, Tel. +7 095 755 6918, Fax. +7 095 755 6919 Singapore: Lorong 1, Toa Payoh, SINGAPORE 319762, Tel. +65 350 2538, Fax. +65 251 6500 Slovakia: see Austria Slovenia: see Italy South Africa: S.A. PHILIPS Pty Ltd., 195-215 Main Road Martindale, 2092 JOHANNESBURG, P.O. Box 7430 Johannesburg 2000, Tel. +27 11 470 5911, Fax. +27 11 470 5494 South America: Al. Vicente Pinzon, 173, 6th floor, 04547-130 SÃO PAULO, SP, Brazil, Tel. +55 11 821 2333, Fax. +55 11 821 2382 Spain: Balmes 22, 08007 BARCELONA, Tel. +34 93 301 6312, Fax. +34 93 301 4107 Sweden: Kottbygatan 7, Akalla, S-16485 STOCKHOLM, Tel. +46 8 5985 2000, Fax. +46 8 5985 2745 Switzerland: Allmendstrasse 140, CH-8027 ZÜRICH, Tel. +41 1 488 2741 Fax. +41 1 488 3263 Taiwan: Philips Semiconductors, 6F, No. 96, Chien Kuo N. Rd., Sec. 1, TAIPEI, Taiwan Tel. +886 2 2134 2865, Fax. +886 2 2134 2874 Thailand: PHILIPS ELECTRONICS (THAILAND) Ltd., 209/2 Sanpavuth-Bangna Road Prakanong, BANGKOK 10260, Tel. +66 2 745 4090, Fax. +66 2 398 0793 Turkey: Talatpasa Cad. No. 5, 80640 GÜLTEPE/ISTANBUL, Tel. +90 212 279 2770, Fax. +90 212 282 6707 Ukraine: PHILIPS UKRAINE, 4 Patrice Lumumba str., Building B, Floor 7, 252042 KIEV, Tel. +380 44 264 2776, Fax. +380 44 268 0461 United Kingdom: Philips Semiconductors Ltd., 276 Bath Road, Hayes, MIDDLESEX UB3 5BX, Tel. +44 181 730 5000, Fax. +44 181 754 8421 United States: 811 East Arques Avenue, SUNNYVALE, CA 94088-3409, Tel. +1 800 234 7381 Uruguay: see South America Vietnam: see Singapore Yugoslavia: PHILIPS, Trg N. Pasica 5/v, 11000 BEOGRAD, Tel. +381 11 625 344, Fax.+381 11 635 777

For all other countries apply to: Philips Semiconductors, International Marketing & Sales Communications, Building BE-p, P.O. Box 218, 5600 MD EINDHOVEN, The Netherlands, Fax. +31 40 27 24825

Internethttp://www.semiconductors.philips.com

© Philips Electronics N.V. 1998 SCA60

All rights are reserved. Reproduction in whole or in part is prohibited without the prior written consent of the copyright owner. The information presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable and may be changed without notice. No liability will be accepted by the publisher for any consequence of its use. Publication thereof does not convey nor imply any license under patent- or other industrial or intellectual property rights.

Printed in The Netherlands 125108/00/03/pp12 Date of release: 1998 May 13 Document order number: 9397 750 03849

Vraag stellen over de Philips BGY148A

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Philips BGY148A

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Philips BGY148A handleiding-pdf

12 pagina's·84 KB·Stereoversterker·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…