NL
Planar logo
Officiële handleiding

Planar PS4200TL

21 pagina's·205 KB·Koolmonoxidemelder·PDF·EN
Planar PS4200TL
Inhoudsopgave 2 secties 006 : DVI · 001: ECO TonenVerbergen
Page 1 of the Planar PS4200TL user manual
Pagina 1 · klik om te vergroten
Pagina 1
Page 1 of the Planar PS4200TL user manual
Page 2 of the Planar PS4200TL user manual
Pagina 2 · klik om te vergroten
Pagina 2

1 Introduction This document describes the hardware interface spec and software protocols of RS232 interface communication between Commercial Display and PC or other control unit with RS232 protocol. 1. Protocol 1, with ID This set protocol allow user to assign the ID in the command to control the specify ID monitor 2. Protocol 2, without ID The set protocol is best for single display control Both sets protocol contain three sections command:

Set-Function Get-Function Remote control pass-through mode

Planar PS4200TL diagram (page 2)
Afb. 1
Pin #SignalRemark 1NC 2RXDInput to LCD Monitor 3TXDOutput from LCD Monitor 4NC 5GND 6NC 7NC 8NC 9NC frameGND
Planar PS4200TL diagram (page 2)
Afb. 2

- Baud Rate Select: 9600bps (fixed) - Data bits: 8bits (fixed) - Parity: None (fixed) - Stop Bits: 1(fixed) 2.3 Command Message Reference PC sends to Monitor command packet followed by “CR”. Every time PC sends control command to the Monitor, the Monitor shall response as follows:

Page 3 of the Planar PS4200TL user manual
Pagina 3 · klik om te vergroten
Pagina 3
1. If the message is receives correctly it will send “+” (02Bh) followed by “CR” (00Dh) 2. If the message is receives incorrectly it will send “-” (02Dh) followed by “CR” (00Dh) 3 Protocol 1: with ID 3.1 Command Description

Length: Total Byte of Message excluding “CR” TV ID Identification for each of TV Command Type

Identify command type, “s” (0x73h) : Set Command “g” (0x67h) : Get Command “r” (0x72h) : Reply Command “p” (0x70h) : RCU Pass-through “+” (0x2Bh) : Valid command Reply “-“ (0x2Dh) : Invalid command Reply Command: Function command code: One byte ASCII code Value[1~3]: Three bytes ASCII that defines the value CR 0x0D 3.2 Set-Function Listing The PC can control the LCD Monitor for specific actions. The Set-Function command allows you to control the LCD monitor behavior in a remote sit through the RS232 port. The Set-Function packet format consists of 11 bytes. Set-Function description:

Length: Total Byte of Message excluding “CR” TV ID Identification for each of TV If we want to set all TV settings, TV ID can use “99” to achieve, and it will not have Reply command on this function. Command Type

Identify command type, “s” (0x73h) : Set Command Command: Function command code: One byte ASCII code Value[1~3]: Three bytes ASCII that defines the value CR 0x0D Set-Function format Send: (Command Type=”s”)

NameLengt hIDCommand TypeComman dValue 1Value 2Value 3CR Byte Count1 Byte2 Byte1 Byte Bytes order12~3456789
Planar PS4200TL diagram (page 3)
Afb. 3
NameLengt hIDCommand TypeCR Byte1 Byte21 Byte1
Page 4 of the Planar PS4200TL user manual
Pagina 4 · klik om te vergroten
Pagina 4
CountByteByte Bytes order12~345
Example1Set Brightness as 76 for TV-02 and this command is valid Send (Hex Format)
NameLengt hIDCommand TypeComman dValue 1Value 2Value 3CR Hex0x380x30 0x320x730x240x300x370x360x0 D
Planar PS4200TL diagram (page 4)
Afb. 4
NameLengt hIDCommand TypeCR Hex0x340x30 0x320x2B0x0 D
NameLengt hIDCommand TypeComman dValue 1Value 2Value 3CR Hex0x380x30 0x320x730x240x310x370x360x0 D
Planar PS4200TL diagram (page 4)
Afb. 5
NameLengt hIDCommand TypeCR Hex0x340x30 0x320x2D0x0 D
NameLengt hIDCommand TypeComman dValue 1Value 2Value 3CR Hex0x380x30 0x330x730x270x300x330x320x0 D
Planar PS4200TL diagram (page 4)
Afb. 6
NameLengt hIDCommand TypeCR Hex0x340x30 0x330x2B0x0 D
NameLengt hIDCommand TypeComman dValue 1Value 2Value 3CR Hex0x380x30 0x330x730x270x300x370x350x0 D
Planar PS4200TL diagram (page 4)
Afb. 7
Page 5 of the Planar PS4200TL user manual
Pagina 5 · klik om te vergroten
Pagina 5
NameLengt hIDCommand TypeCR Hex0x340x30 0x330x2D0x0 D
Planar PS4200TL diagram (page 5)
Afb. 8
NameLengt hIDCommand TypeComman dValue 1Value 2Value 3CR Hex0x380x39 0x390x730x240x300x370x360x0 D
Set FunctionLenIDCmd TypeCommand Code Code (ASCII) (Hex)Value Range (Three ASCII bytes)Comments Picture mode8s81000: STANDARD 001: VIVID 002: CINEMA 003: USER Contrast8s#23000 ~ 100 Brightness8s$24000 ~ 100 Color8s82000 ~ 100 Tint8s83000 ~ 100 Sharpness8s%25000 ~ 010 Backlight8s84000 ~ 100Step : 20 for OSD display range 0~5 DCR8s85000: OFF 001: ON Color Temp8S86000: 12000K 001: 9300K 002: 6500K 004: User Input Resolution8s87000: AUTO 001: 1024x768 002: 1280x768 003: 1360x768 004: 1366x768 Volume8s535000 ~ 100
Planar PS4200TL diagram (page 5)
Afb. 9

Reply (Hex Format)

Page 6 of the Planar PS4200TL user manual
Pagina 6 · klik om te vergroten
Pagina 6
Planar PS4200TL diagram (page 6)
Afb. 10
Mute8s636000: OFF 001: ON Audio Source8s88000: Audio1 001: HDMI 002: Audio2 003: Audio3 Speaker8s89000: Internal 001: External 002: LineoutOnly effected for models include internal speakers. Aspect Ratio8s131000: Full 001: Original PIP Enable8s8A000: OFF 001: ON PIP Main Input8s8B000: VGA 001: YPbPr 002: DVI 003: HDMI PIP Sub Input8s8C000: VGA 001: YPbPr 002: DVI 003: HDMI PIP Size8s8D000: Small 001: Middle 002: Large PIP Position8s8E000: Move Down 001: Move Up 002: Move Left 003: Move Right Video Source8s“22000 : VGA 001 : HDMI1 003 : CVBS1 004 : YPbPr 005 : S-Video 006 : DVI Auto adjustment8s8F
Page 7 of the Planar PS4200TL user manual
Pagina 7 · klik om te vergroten
Pagina 7
Planar PS4200TL diagram (page 7)
Afb. 11
Clock frequency8s90000 ~ 32 Phase8s91000 ~ 32 H.Position8s92000 ~ 100 V.Position8s93000 ~ 100 Ambient Light Sensor8s94000: OFF 001: ON Blue Screen8s95000: OFF 001: ON Auto Detect8s96000: OFF 001: ON Touch Feature8s9E000: OFFOnly effected for Touch models. 001: On Language8s232000: English 001: French 002: Spanish 003: CzechOptional by different models. 004: DanishOptional by different models. Over Scan8s97000: OFF 001: ON RTC Year8s98000 ~ 099From 2000~2099 RTC Month8s99000 ~ 012 RTC Day8s9A000 ~ 031 RTC Hour8s9B000 ~ 023 RTC Minute8s9C000 ~ 059 Daylight saving time8s9D000: OFF 001: ON H Monitor8sA4001 ~ 010 V Monitor8sA5001 ~ 010 H Position8sA6001 ~ 010 V Position8sA7001 ~ 010 Frame Comp.8sA8000: OFF 001: ON Power save8sA9000: OFF 001: Eco
Page 8 of the Planar PS4200TL user manual
Pagina 8 · klik om te vergroten
Pagina 8
Planar PS4200TL diagram (page 8)
Afb. 12
002: VGA Only 003: Standard Monitor ID8s=3D001 ~ 098 Image retention8sG47000: OFF 001: ON Auto adjustment8sAA000: OFF 001: ON DDC/CI8sAB000: OFF 001: ON Reset User Default8sAC OSD Info Box8s[5B000: OFF 001: ON Store User Default8sAD Factory Reset8s~7E Power8s!21000: STBY 001: ON Key Pad8sA41000 : POWER 001 : SOURCE 002 : MENU 003 : UP 004 : DOWN 005 : LEFT 006 : RIGHT 007 : MUTE Remote Control8sB42000: Disable 001: Enable 002: Pass through Key Pad function8sC43000: Disable 001: Enable Menu Key function8sE45000: Disable 001: Enable Power Key function8sF46000: Disable 001: Enable

3.3 Get-Function Listing The PC can interrogate the LCD Monitor for specific information. The Get-Function packet format consists of 5 bytes which is similar to the Set-Function packet structure. Note that the “Value” byte is always = 00.

Page 9 of the Planar PS4200TL user manual
Pagina 9 · klik om te vergroten
Pagina 9

Get-Function description:

Length: Total Byte of Message excluding “CR” TV ID Identification for each of TV Command Type

Identify command type, “g” (0x67h) : Get Command Command: Function command code: One byte ASCII code Value[1~3]: Three bytes ASCII that defines the value NOTE: to get backlight senor, thermal sensor, and ambient sensor need four bytes ASCII that defines the value and the length is 9. CR 0x0D Get-Function format Send: (Command Type=”g”)

NameLengt hIDCommand TypeComman dValue 1Value 2Value 3CR Byte Count1 Byte2 Byte1 Byte Bytes order12~3456789
Planar PS4200TL diagram (page 9)
Afb. 13
Reply(Command Type=”r” or “-”) If the Command is valid, Command Type =”r”
NameLengt hIDCommand TypeComman dValue 1Value 2Value 3CR Byte Count1 Byte2 Byte1 Byte Bytes order12~3456789
Planar PS4200TL diagram (page 9)
Afb. 14
NameLengt hIDCommand TypeCR Byte Count1 Byte2 Byte1 Byte1 Byte Bytes order12~345

Example1: Get Brightness from TV-05 and this command is valid. The Brightness value is 67. Send (Hex Format)

NameLengt hIDCommand TypeComman dValue 1Value 2Value 3CR Hex0x380x30 0x350x670x620x300x300x300x0 D
Planar PS4200TL diagram (page 9)
Afb. 15
Page 10 of the Planar PS4200TL user manual
Pagina 10 · klik om te vergroten
Pagina 10

Hex 0x38 0x30 0x35 0x72 0x62 0x30 0x36 0x37 0x0 D Example2: Get Brightness from TV-05 , but the Brightness command ID is error and it is NOT in the command table. Send (Hex Format)

NameLengt hIDCommand TypeComman dValue 1Value 2Value 3CR Hex0x380x30 0x350x670XD30x300x300x300x0 D
Planar PS4200TL diagram (page 10)
Afb. 16
NameLengt hIDCommand TypeCR Hex0x340x30 0x350x2D0x0 D
NameLengt hIDCommand TypeComman dValue 1Value 2Value 3CR Hex0x380x30 0x370x670X650x300x300x300x0 D
Planar PS4200TL diagram (page 10)
Afb. 17
NameLengt hIDCommand TypeComman dValue 1Value 2Value 3CR Hex0x380x30 0x370x720x650x300x330x320x0 D
NameLengt hIDCommand TypeComman dValue 1Value 2Value 3CR Hex0x380x30 0x370x670XD70x300x300x300x0 D
Planar PS4200TL diagram (page 10)
Afb. 18
NameLengt hIDCommand TypeCR Hex0x340x30 0x370x2D0x0 D
Page 11 of the Planar PS4200TL user manual
Pagina 11 · klik om te vergroten
Pagina 11
NameLengt hIDCommand TypeComman dValue 1Value 2Value 3Value 4CR Hex0x390x30 0x370x670X6F0x300x300x300x300x0 D
Planar PS4200TL diagram (page 11)
Afb. 19
NameLengt hIDCommand TypeComman dValue 1Value 2Value 3Value 3CR Hex0x390x30 0x370x720X6F0x310x370x380x360x0 D
NameLengt hIDCommand TypeComman dValue 1Value 2Value 3Value 4CR Hex0x390x30 0x370x670X700x300x300x300x300x0 D
Planar PS4200TL diagram (page 11)
Afb. 20
NameLengt hIDCommand TypeComman dValue 1Value 2Value 3Value 4CR Hex0x390x30 0x370x720X700x310x350x360x380x0 D

Example7 Get thermal sensor from TV-0007 and this command is valid. The value is +075 degree (ASCII code). NOTE: positive degree is “+”ASCII code and negative degree is “-”ASCII code. Send (Hex Format)

NameLengt hIDCommand TypeComman dValue 1Value 2Value 3Value 4CR Hex0x390x30 0x370x670X710x300x300x300x300x0 D
Planar PS4200TL diagram (page 11)
Afb. 21
NameLengt hIDCommand TypeComman dValue 1Value 2Value 3Value 4CR Hex0x390x30 0x370x720X710x2B0x300x370x350x0 D
Planar PS4200TL diagram (page 11)
Afb. 22

Example8 Get Running Hours from TV-0007 and this command is valid. The value is 21,356 hours (ASCII code). Send (Hex Format)

Name Lengt ID Command Comman Value CR

Reply (Hex Format)

Page 12 of the Planar PS4200TL user manual
Pagina 12 · klik om te vergroten
Pagina 12
Planar PS4200TL diagram (page 12)
Afb. 23
hTyped12345 Hex0x3A0x30 0x370x670X760x300x300x300x300x300x0 D
Planar PS4200TL diagram (page 12)
Afb. 24
NameLengt hIDCommand TypeComman dValue 1Value 2Value 3Value 4Value 5CR Hex0x3A0x30 0x370x720X760x320x310x330x350x360x0 D

Reply (Hex Format)

Page 13 of the Planar PS4200TL user manual
Pagina 13 · klik om te vergroten
Pagina 13

PC Get-function command to LCD Monitor

Planar PS4200TL diagram (page 13)
Afb. 25

Get Function Len ID Cmd Command Value Range Comments Type Code (ASCII)

Backlight 8 g B4 000 ~ 100 Step : 20 for OSD display range 0~5 DCR 8 g B5 000: OFF

Speaker 8 g B9 000Internal Only effected for models include internal speakers. 001: External
2. Lineout
Page 14 of the Planar PS4200TL user manual
Pagina 14 · klik om te vergroten
Pagina 14
Planar PS4200TL diagram (page 14)
Afb. 26

Touch Feature 8 g CE 000: OFF Only effected for Touch models. 001: ON

Language 8 g 78 000English
1. French
2. Spanish
Page 15 of the Planar PS4200TL user manual
Pagina 15 · klik om te vergroten
Pagina 15
Planar PS4200TL diagram (page 15)
Afb. 27
3. Czech, Optional by different models. 004: Danish Optional by different models. Over Scan 8 g C7 000: OFF

RTC Year 8 g C8 000 ~ 099 From 2000~2099

FW Version 16 g DC PS5550 p.xx (ASCII), the return value will be different for different model OSD Info Box 8 g 5D 000: OFF

Power 8 g 6C 000STBY
Page 16 of the Planar PS4200TL user manual
Pagina 16 · klik om te vergroten
Pagina 16
Planar PS4200TL diagram (page 16)
Afb. 28

Key Pad function 8 g 69 000: Disable Lock

1. Enable Menu Key function 8 g 73 000: Disable Lock
1. Enable 5V 8 g m 6D 000~50 12V 8 g n 6E 000~120 Ambient Sensor 9 g p 70 0000 ~ 2000 Thermal Sensor 9 g q 71 -055 ~ +125 Operating Time A g v 76 0 ~ 65535 Hour

4 Protocol 2 : without ID 4.1 Set function listing The PC can control the LCD Monitor for specific actions. The Set-Function command allows you to control the LCD monitor behavior in a remote sit through the RS232 port. The Set-Function packet format consists of 5 bytes. Note that the “Value” byte is always = 00. Set-Function description:

Length: Total bytes of message = 5 ASCII (35H) excluding “CR” Command: Function command code: One byte ASCII code Value[1~3]: Three bytes ASCII that defines the value Set-Function format:

Name Length Command Value1 Value2 Value3 CR Byte Count 1 Byte 1 Byte 1 Byte 1 Byte 1 Byte 1 Byte Bytes order 1 2 3 4 5 6 All Set-Function from PC to Monitor (ASCII)

Name Length Command Value1 Value2 Value3 CR Byte Count 5 1 Byte 1 Byte 1 Byte 1 Byte 00D Bytes order 1 2 3 4 5 6 Example: Set Mute-ON command (ASCII)

Name Length Command Value1 Value2 Value3 CR Byte Count 5 6 00D Bytes order 1 2 3 4 5 6

Page 17 of the Planar PS4200TL user manual
Pagina 17 · klik om te vergroten
Pagina 17
ExampleSet Mute-OFF command (ASCII)

Name Length Command Value1 Value2 Value3 CR Byte Count 5 6 0 0 1 00D Bytes order 1 2 3 4 5 6 LCD Monitor will send “+” (02Bh) and “CR” bytes to PC after receiving a valid command. LCD Monitor will send “-” (02Dh) and “CR” bytes to PC if the command is not valid.

Value RangeThree bytes ASCII value range

Function command code in ASCII

Code:

Planar PS4200TL diagram (page 17)
Afb. 29

Backlight 5 84 000 ~ 100 Step : 20 for OSD display range 0~5 DCR 5 85 000: OFF

3. 1360x768
4. 1366x768

Volume 5 35 000 ~ 100

Command · set command table

Page 18 of the Planar PS4200TL user manual — 006 : DVI
Pagina 18 · klik om te vergroten
Pagina 18
Planar PS4200TL — 006 : DVI diagram (page 18)
Afb. 30
Speaker 5 89 000Internal Only effected for models include internal speakers. 001: External
5. S-Video

006 : DVI

Auto adjustment 5 8F

Page 19 of the Planar PS4200TL user manual — 001: ECO
Pagina 19 · klik om te vergroten
Pagina 19
Planar PS4200TL — 001: ECO diagram (page 19)
Afb. 31
Touch Feature 5 9E 000OFF Only effected for Touch models. 001: ON
3. Czech, Optional by different models. 004: Danish Optional by different models. Over Scan 5 97 000: OFF

RTC Year 5 98 000 ~ 099 From 2000~2099

Power save 5 A9 000OFF

001: ECO

2. VGA Only
Page 20 of the Planar PS4200TL user manual — 001: ECO
Pagina 20 · klik om te vergroten
Pagina 20
Planar PS4200TL — 001: ECO diagram (page 20)
Afb. 32

Monitor ID 5 3D 001 ~ 098 Image retention 5 47 000: OFF 001: ON Auto adjustment 5 AA 000: OFF 001: ON DDC/CI 5 AB 000: OFF 001: ON Reset User Default 5 AC OSD Info Box 5 5B 000: OFF 001: ON Store User Default 5 AD Factory Reset 5 7E Power 5 21 000: STBY 001: ON Key Pad 5 41 000 : POWER 001 : SOURCE 002 : MENU 003 : UP 004 : DOWN 005 : LEFT 006 : RIGHT 007 : MUTE Remote Control 5 42 000: Disable

Key Pad function 5 43 000: Disable 001: Enable Menu Key function 5 45 000: Disable 001: Enable Power Key function

5 46 000Disable 001: Enable

4.2 Remote Control Pass-through mode When PC sets the LCD monitor to Remote Control Pass through mode, the LCD shall send a three bytes packet (followed by “CR”) in response to RCU button activation. Note, that in this mode the RCU shall have no effect on the monitor function. For example: “+Volume” will not change the volume in the LCD but only sends “+Volume” code to PC over the RS232 port. Remote Control pass-through packet format from LCD monitor to PC(ASCII)

Name Length RCU-Code1 RCU-Code2 CR Byte Count 3 MSB LSB 00D Bytes order 1 2 3 4 Example: Remote Control pass-through when “Menu” key is pressed (2E)

Name Length RCU-Code1 RCU-Code2 CR Byte Count 3 2 E 00D

Page 21 of the Planar PS4200TL user manual — 001: ECO
Pagina 21 · klik om te vergroten
Pagina 21

Bytes order 1 2 3 4 Example: Remote Control pass-through when key “DOWN” is pressed (21)

Name Length RCU-Code1 RCU-Code2 CR Byte Count 3 2 1 00D Bytes order 1 2 3 4 Example: Remote Control pass-through when “Power” key is pressed (0C)

Planar PS4200TL — 001: ECO diagram (page 21)
Afb. 33

Name Length RCU-Code1 RCU-Code2 CR Byte Count 3 0 C 00D Bytes order 1 2 3 4

RCU Key Support CODE (HEX) Notes PWR Y 0C Exit Y 0F = MENU key Vol + Y 10 Vol - Y 11 UP Y 20 DOWN Y 21 Mute Y 0D Enter Y 0A = SOURCE key Menu Y 2E Information Y 12 Input Y 28 = SOURCE key DVI Y 4B VGA Y 39 HDMI Y 38 AV Y 37 YPbPr Y 70

Vraag stellen over de Planar PS4200TL

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Planar PS4200TL

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Planar PS4200TL handleiding-pdf

21 pagina's·205 KB·Koolmonoxidemelder·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…