Gebruiksaanwijzing /service van het product CPF23400P van de fabrikant Porter-Cable
Ga naar pagina of 18
Part No. D20919-004 Pancake Compr essor Instruction manual T o learn more about Porter -Cable visit our website at: http://www .porter -cable.com The Model and Serial No. plate is located on the frame. Record these numbers in the spaces below and retain for future reference.
2-ENG CAUTION indicates a potentially hazar dous situation which, if not avoided, may result in minor or moderate injury . This manual contains information that is important for you to know and understand. This infor - mation relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS .
3-ENG RISK OF BURSTING IT IS NORMAL FOR ELECTRICAL CONT ACTS WITHIN THE MOTOR AND PRESSURE SWITCH TO SP ARK. IF ELECTRICAL SP ARKS FROM COMPRESSOR COME INTO CONT ACT WITH FLAMMABLE V APORS, THEY MAY IGNITE, CAUSING FIRE OR EXPLOSION. RESTRICTING ANY OF THE COMPRESSOR VENTILA TION OPENINGS WILL CAUSE SERIOUS OVERHEA TING AND COULD CAUSE FIRE.
4-ENG RISK FROM FL YING OBJECTS IMPORT ANT SAFETY INSTRUCTIONS (cont’d) THE COMPRESSED AIR STREAM CAN CAUSE SOFT TISSUE DAMAGE TO EXPOSED SKIN AND CAN PROPEL DIRT , CHIPS, LOOSE P ARTICLES AND SMALL OBJECTS A T HIGH SPEED , RESUL TING IN PROPERTY DAMAGE OR PERSONAL INJUR Y .
5-ENG RISK FROM MOVING P ARTS RISK OF BURNS RISK OF F ALLING IMPORT ANT SAFETY INSTRUCTIONS (cont’d) WHA T CAN HAPPEN HOW TO PREVENT IT WHA T CAN HAPPEN HOW TO PREVENT IT WHA T CAN HAPPEN HOW TO PREVENT IT MOVING P ARTS SUCH AS THE PULLEY , FL YWHEEL, AND BEL T CAN CAUSE SERIOUS INJUR Y IF THEY COME INTO CONT ACT WITH YOU OR YOUR CLOTHING.
6-ENG CFM: Cubic feet per minute. SCFM: Standard cubic feet per minute; a unit of measur e of air delivery . PSIG: Pounds per square inch gauge; a unit of measur e of pressure. ASME: American Society of Mechanical Engineers; made, tested, inspected, and register ed to meet the standards of ASME.
7-ENG DESCRIPTION OF OPERA TION Drain V alve (not shown): The drain valve is located at the base of the air tank and is used to drain condensation at the end of each use. Motor Thermal Overload Protector (not shown): The electric motor has an automatic thermal overload protector .
8-ENG INST ALLA TION Location of the Air Compr essor Locate the air compressor in a clean, dry , and well-ventilated area. The air filter must be kept clear of obstructions which could r educe air flow to the air compr essor .
9-ENG GROUNDING INSTRUCTIONS RISK OF ELECTRICAL SHOCK! In the event of a short circuit, gr ounding reduces the risk of shock by providing an escape wire for the electric current.
10-ENG OPERA TING PROCEDURES Daily Start-Up Checklist 1. Before attaching air hose or accessories, make sure the ON/AUTO lever is set to “OFF” and the air regulator is closed. 2. Attach hose and accessories. TOO MUCH AIR PRESSURE CAUSES A HAZARDOUS RISK OF BURSTING.
11-ENG SERVICE INSTRUCTIONS Air Filter - Inspection and Replacement Keep the air filter clean at all times. Do not operate the compressor with the air filter removed. A dirty air filter will not allow the compressor to operate at full capacity . Befor e you use the compressor , check the air filter to be sur e it is clean.
12-ENG 5. Check that the valve disc moves freely inside the check valve and that the spring holds the disc in the upper , closed position. The check valve may be cleaned with a strong solvent. 6. Apply sealant to the check valve threads. Reinstall the check valve.
13-ENG CAUSE PERFORMING REP AIRS MA Y EXPOSE VOL T AGE SOURCES, MOVING P AR TS OR COMPRESSED AIR SOURCES. PERSONAL INJUR Y MA Y OCCUR. PRIOR TO A TTEMPTING ANY REP AIRS, UNPLUG THE AIR COMPRESSOR AND BLEED OFF ALL AIR T ANK AIR PRESSURE. PROBLEM CORRECTION TROUBLESHOOTING GUIDE Excessive tank pressure - safety valve pops off.
14-ENG CAUSE PROBLEM CORRECTION Motor will not run or restart. Motor overload pr otection switch has tripped. T ank pressure exceeds pr essure switch “cut-in” pr essure. W rong gauge wire or length of extension cor d. Check valve stuck open. Loose electrical connections.
15-ENG Operate safety valve manually by pulling on ring. If valve still leaks, it should be replaced. Possible defect in safety valve. Air leak from safety valve. CAUSE PROBLEM CORRECTION Knocking Noise. Defective check valve. Remove and clean, or r eplace.
16-ENG ACCESSORIES Accessories can be found at the store the unit was purchased or at a local hardwar e store . PLUMBING COMPONENTS CONNECTORS Connects components that have similar NPT threads; Male or Female. 360 O SWIVEL CONNECTOR Eliminates hose twist and improves tool handling.
17-ENG NOTES.
18-ENG LIMITED WARRANTY POR TER-CABLE CORPORA TION warrants to the original purchaser that each new air compressor and service part is free fr om defects in material and workmanship and agrees to repair or replace under this warranty any defective pr oduct or part as follows fr om the original date of purchase.
Een belangrijk punt na aankoop van elk apparaat Porter-Cable CPF23400P (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Porter-Cable CPF23400P heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Porter-Cable CPF23400P vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Porter-Cable CPF23400P leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Porter-Cable CPF23400P krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Porter-Cable CPF23400P bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Porter-Cable CPF23400P kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Porter-Cable CPF23400P . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.