Gebruiksaanwijzing /service van het product D26126-024-0 van de fabrikant Porter-Cable
Ga naar pagina of 18
Pancake Compr essor Instruction manual The Model and Serial No. plate is located on the main housing of the tool. Record these numbers in the spaces below and retain for future reference. Model No. ______________________________________ Type ___________________________________________ Serial No.
2 - ENG D26126 SAFETY GUIDELINES - DEFINITIONS Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury . Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
3 - ENG D26126 IMPORT ANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS IMPROPER OPERATION OR MAINTENANCE OF THIS PRODUCT COULD RESULT IN SERIOUS INJURY AND PROPERTY DAMAGE. READ AND UNDERSTAND ALL WARNINGS AND OPERATING INSTRUCTIONS BEFORE USING THIS EQUIPMENT.
4 - ENG D26126 HAZARD RISK OF BURSTING AIR TANK: THE FOLLOWING CONDITIONS COULD LEAD TO A WEAKENING OF THE TANK, AND RESULT IN A VIOLENT TANK EXPLOSION AND COULD CAUSE PROPERTY DAMAGE OR SERIOUS INJURY. HOW TO PREVENT IT WHAT CAN HAPPEN DRAIN TANK DAILY OR AFTER EACH USE.
5 - ENG D26126 HAZARD HAZARD HOW TO PREVENT IT WHAT CAN HAPPEN RISK TO BREATHING AIR OBTAINED DIRECTLY FROM THE COMPRESSOR SHOULD NEVER BE USED TO SUPPLY AIR FOR HUMAN CONSUMPTION. IN ORDER TO USE AIR PRODUCED BY THIS COMPRESSOR FOR BREATHING, SUITABLE FILTERS AND IN-LINE SAFETY EQUIPMENT MUST BE PROPERLY INSTALLED .
6 - ENG D26126 HAZARD HOW TO PREVENT IT WHAT CAN HAPPEN RISK OF BURNS TOUCHING EXPOSED METAL SUCH AS THE COMPRESSOR HEAD OR OUTLET TUBES, CAN RESULT IN SERIOUS BURNS. NEVER TOUCH ANY EXPOSED METAL PARTS ON COMPRESSOR DURING OR IMMEDIATELY AFTER OPERATION.
7 - ENG D26126 HAZARD HOW TO PREVENT IT WHAT CAN HAPPEN RISK OF UNSAFE OPERATION REVIEW AND UNDERSTAND ALL INSTRUCTIONS AND WARNINGS IN THIS MANUAL. BECOME FAMILIAR WITH THE OPERATION AND CONTROLS OF THE AIR COMPRESSOR. KEEP OPERATING AREA CLEAR OF ALL PERSONS, PETS, AND OBSTACLES.
8 - ENG D26126 GLOSSAR Y SCFM or CFM: Standard Cubic Feet per Minute; a unit of measurement of air delivery. PSIG or PSI: Pounds per square inch gauge. CUT-IN PRESSURE : While the motor is off, air tank pressure drops as you continue to use your accessory or air tool.
9 - ENG D26126 HOW TO SET UP YOUR UNIT Location of the Air Compressor Locate the air compressor in a clean, dry and well ventilated area. The air compressor should be located at least 12" away from the wall or other obstructions that will interfere with the flow of air.
10 - ENG D26126 Extension Cords Using extension cords is not recommended. The use of extension cords will cause voltage to drop resulting in power loss to the motor and overheating. Attach extra air hoses at the air outlet instead of using extension cords.
11 - ENG D26126 DESCRIPTION OF OPERA TION Description of Operation Become familiar with these controls before operating the unit. On/Auto/Off Switch : Turn this switch ON to provide automatic power to the pressure switch and OFF to remove power at the end of each use.
Air Compressor Pump (not shown): Compresses air into the air tank. Working air is not available until the compressor has raised the air tank pressure above that required at the air outlet. Check Valve: When the air compressor is operating, the check valve is "open”, allowing compressed air to enter the air tank.
13 - ENG D26126 Before Each Start-Up: 1. Place On/Auto/Off lever to "OFF" and close air regulator. 2. Pull regulator knob out, turn counterclockwise until it stops.
14 - ENG D26126 Customer Responsibilities Daily or after each use Before each use ● ● Check Safety Valve Drain Tank NOTE: See "Operation" section for the location of controls. Unit cycles automatically when power is on. When performing maintenance, you may be exposed to voltage sources, compressed air, or moving parts.
15 - ENG D26126 Unit cycles automatically when power is on. When doing Maintenance, you may be exposed to voltage sources, compressed air or moving parts. Personal injuries can occur. Before performing any Maintenance or repair, unplug the compressor and bleed off all air pressure.
To Replace Regulator 1. Release all air pressure from air tank. See "To Drain Tank" in the Maintenance section. 2. Unplug unit. 3. Using an adjustable wrench remove the outlet pressure gauge and quick connect from the regulator. 4. Remove the regulator.
17 - ENG D26126 Before you store the air compressor, make sure you do the following: 1. Review the "Maintenance" section on the preceding pages and perform scheduled maintenance as necessary. 2. Set the On/Auto/Off lever to “OFF”. 3. Turn the regulator counterclockwise and set the outlet pressure to zero.
LIMITED WARRANTY Porter-Cable Corporation Jackson, TN USA 1-888-559-8550 PORTER-CABLE CORPORATION warrants to the original purchaser that all products covered under this warranty are free from defects in material and workmanship.
Een belangrijk punt na aankoop van elk apparaat Porter-Cable D26126-024-0 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Porter-Cable D26126-024-0 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Porter-Cable D26126-024-0 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Porter-Cable D26126-024-0 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Porter-Cable D26126-024-0 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Porter-Cable D26126-024-0 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Porter-Cable D26126-024-0 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Porter-Cable D26126-024-0 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.