Gebruiksaanwijzing /service van het product QVI-25FB-S van de fabrikant Quadra-Fire
Ga naar pagina of 39
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 1 Model: QVI-25FB-S • Do not store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any other appliance. • What to do if you smell gas - Do not try to light any appliance - Do not touch any electrical switch.
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 2 Congratulations Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: ________.
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 3 T able of Contents 1 Listing and Code Approvals A. Appliance Certi fi cation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 B. BTU Speci fi cations . . . . . . . . . . . . . . . .
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 4 Note : T o assure top performance, safety and ef fi ciency , inserts must be installed with an approved fl ue liner as per CAN/CGA B-149 or National Fuel Gas Code ANSI Z223 and these instructions.
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 5 Quadra-Fire gas inserts are designed for recessed installa- tions into solid fuel masonry or factory built non-combustible fi replaces that have been installed in accordance with the National, Provincial, State and local building codes.
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 6 3 3 F ireplace Size Requirements A. Minimum Fireplace Opening Minimum fi replace opening requirements are shown in Figure 3.
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 7 B. Clearances Figure 3.2 Clearances to Mantels or other Combustibles above Appliance Fire Risk. • Locate and install appliance to all clearance speci fi cations in manual. Fire Risk. Odor Risk.
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 8 Fire Risk. Asphyxiation Risk. • T erminations MUST meet minimum clearances. • Exhaust gases are hot. • Nearby vents may draw fumes into house. A. V ent T ermination Minimum Clearances Figure 4.
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 9 CAUTION ALL vent speci fi cations MUST be followed. • This product is tested and listed to these speci fi cations. • Appliance performance will suffer if speci fi cations are not followed.
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 10 6 6 Installation Preparation Fire Risk. A hearth or hearth extension (if present) must comply with either of the following: • The solid fuel burning fi replace manufacturer’s speci fi cation.
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 1 1 A. V enting Components 7 7 Installing V ent P ipe and Appliance The vertical vent termination system installed on this model includes: • One 3-foot section stainless steel fl exible pipe (included with insert).
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 12 Figure 7.1 ST AINLESS STEEL ADAPTER FOR EXHAUST (MUST BE INST ALLED) INLET AIR VENT PIPE 3 INCH COLLAR OPTIONAL LINK-ZC-ADPB (For Flashing C.
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 13 Figure 7.2 CUT AND BEND FLASHING AS NEEDED TO FIT CHIMNEY SEALANT ADHESIVE • T rim chimney top plate to minimize excess overhang or bend over fl ue tile (see Figure 7.2). • Place 3/8 inch bead of 300º F silicone on fl ue tile top.
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 14 D. Installing Adaptor and T ermination Cap For installation of termination cap see minimum vent heights for various pitched roofs (see Figure 7.2) . T o install adaptor see Figure 7.3. Roof Pitch H (Min.
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 15 • Ensure that gas line does not come in contact with outer wrap of appliance. Follow local codes. • Incoming gas line should be piped into the valve compartment and connected to the 1/2 inch connection on the manual shutoff valve.
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 16 Fire hazard. Do NOT change the valve settings. • This valve has been preset at the factory . • Changing valve settings may result in fi re hazard or bodily injury . HIGH AL TITUDE INST ALLA TIONS U.
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 17 A. Wiring the Appliance 9 9 Elect rical Infor mation Note : This appliance must be electrically wired and grounded in accordance with local codes or , in the absence of local codes, with National Electric Code ANSI/NFP A 70-latest edition or the Canadian Electric Code, CSA C221.
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 18 B. Junction Box Installation Figure 9.2 Junction box installation FEED PLUG THROUGH HOLE INSERT RELIEF AROUND CORD IN THIS END FROM OUTSIDE OF UNIT JUNCTION BOX SIDE WALL Optional Accessories Connecting the electrical junction box is required if using a blower or remote.
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 19 Figure 9.4 Fan Wiring Diagram JUNCTION BOX VARIABLE SPEED CONTROL TEMPERATURE SENSOR SWITCH WHT GRN BLK BLK 110-120 VAC BLOWER BLOWER RECEPT.
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 20 A. Mantel Projections Figure 10.1 shows the minimum vertical and corresponding maximum horizontal dimensions of appliance mantels or other combustible projections above the top front edge of the appliance, not the surround.
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 21 Figure 1 1.1 Placement of Embers BURNER P AN EMBER PLACEMENT 1 1 11 Appliance Setup A. Remove Shipping Materials Remove shipping materials from inside or underneath the fi rebox.
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 22 E. Positioning the Logs Log Set Assembly: LOGS-2031 2031-700 4 5 6 1 3 2 FIREBOX LEDGE LOG PLACEMENT INSTRUCTIONS Log Placement CAUTION: Logs are fragile! Carefully remove the logs from the packaging.
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 23 LOG #3 (SRV2032-703): Position log #3 by locating its slot over the tab on right front of the burner such that left end of log contacts log tab near the center of the burner . LOG #2 (SRV2032-702): Position log #2 by locating its slot over the tabs on left front of the burner .
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 24 Figure 1 1.2 Glass Assembly F . Glass Assembly Removing Glass Assembly There are two glass latches on the left side of glass as- sembly and two glass latches on the right side. • T o release glass assembly , pull latch forward and allow to retract away from glass assembly .
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 25 Fire Risk. Explosion Risk. Gas may build up while lighting pilot. • Remove glass assembly before lighting pilot. • Replace glass assembly after lighting pilot. A. Before Lighting Appliance This appliance has a Standing Pilot Ignition.
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 26 B. Lighting Appliance Standing Pilot Ignition 1. T urn off all electric power to the appliance if service is to be performed. 2. Open control access panel. 3. Move switch to “OFF” position.
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 27 C. Check Pilot Flame Appearance Pilot fl ame must contact the thermocouple and thermopile for reliable appliance operation.
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 28 E. Frequently Asked Questions Fire Risk. High T emperatures. Keep combustible household items away from appliance. Do NOT obstruct combustion and ventilation air . • Do NOT place combustible items on top of or in front of appliance.
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 29 A. Standing Pilot Ignition System 1 3 13 T roubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service.
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 30 T roubleshooting (continued) Symptom Possible Cause Corrective Action 3. Continued c. Defective valve. T urn the valve knob to the ON position. Place the ON/OFF switch in the ON position. Check the millivolt meter a the thermopile terminals.
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 31 1 4 14 Maintaining and Ser vicing Appliance Although the frequency of appliance servicing and maintenance will depend on use and the type of installation, a quali fi ed service technician should perform an appliance checkup at the beginning of each heating season.
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 32 Inspect Maintenance T asks Doors, Surrounds and Fronts 1. Assess condition of screen and replace as necessary . Recommend addition of screen if one is not present. 2. Inspect for scratches, dents or other damage and repair as necessary .
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 33 Figure 15.1 Appliance Dimensions A 14-7/16 in. 377 mm C E 5-9/16 in. 1-1/16 in. G GAS INLET (GAS BALL V AL VE NOT SHOWN) H F D 3-5/8 in. REF 92 mm 3-7/16 in. 87 mm 1-1/16 in. 27 mm T wo 2-13/16 in.
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 34 B. V ent Kits Components Direct V ent Flex Liner Kits (see Figure 15.2) LINK-DV -30B or (LINK-DV -30): Masonry 3 inch fl ex liner kit. Expands to 30 feet. Includes: two liners, termination cap, fl ashing, and link adapter .
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 35 Service Parts Diagram QVI-25FB-S R Beginning Manufacturing Date: Oct. 2007 Ending Manufacturing Date: ______ C.
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 36 QVI-25FB-S Service Parts IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer .
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 37 IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer .
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 38 D. Limited Lifetime W arranty LIMITED LIFETIME W ARRANTY The Hearth & Home T echnologies limited Lifetime W arranty guarantees that the following components will work as designed for the lifetime of the stove or Hearth & Home T echnologies will repair or replace them.
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . D • 3/08 39 Quadra-Fire, a brand of Hearth & Home T echnologies Inc. 20802 Kensington Boulevard, Lakeville, MN 55044 www .quadra fi re.com E. Contact Information Please contact your Quadra-Fire dealer with any questions or concerns.
Een belangrijk punt na aankoop van elk apparaat Quadra-Fire QVI-25FB-S (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Quadra-Fire QVI-25FB-S heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Quadra-Fire QVI-25FB-S vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Quadra-Fire QVI-25FB-S leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Quadra-Fire QVI-25FB-S krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Quadra-Fire QVI-25FB-S bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Quadra-Fire QVI-25FB-S kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Quadra-Fire QVI-25FB-S . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.