Gebruiksaanwijzing /service van het product CC-SG van de fabrikant Raritan Engineering
Ga naar pagina of 270
CommandCenter ® Secure Gateway CC-SG Administrator Guide Release 3.0 Copyright © 2006 Raritan, Inc. CCA-0B-E May 2006 255-80-5140-00.
This page intentionally left blank..
Copyright and Tradem ark Information This document contains proprietary information that is protected by copyright. All rights reserved. No part of this document may be phot ocopied, reproduced, or tr anslated into another language without express prior written consent of Raritan, Inc.
Safety Guidelines To avoid potentially fatal shock hazard a nd possible damage to Raritan equipm ent: • Do not use a 2-wire power cord in any product configuration. • Test AC outlets at your computer and monitor for proper polarity and ground ing.
C ONTENTS i Content s Chapter 1: Introduction ....................................................................................................1 Prerequisi tes ........................................................................................
ii C ONTENTS Copy Device C onfigurat ion .............................................................................................................. 57 Upgrade De vice ................................................................................
C ONTENTS iii Edit Po licy ...................................................................................................................................... 111 Delete Policy .......................................................................
iv C ONTENTS Inactivity Timer Configur ation ................................................................................................. ....... 164 Time/Date Conf igurat ion ......................................................................
C ONTENTS v CC-SG & SNMP ................................................................................................................... ......... 234 CC-SG & CC-NOC .........................................................................
vi F IGURES Figur es Figure 1 CC-SG Front View ...................................................................................................... ................... 1 Figure 2 CC-SG - Rear Panel ...................................................
F IGURES vii Figure 52 Add Device Selecti on Screen .......................................................................................... .......... 51 Figure 53 Add Device Screen for Po werStrip...................................................
viii F IGURES Figure 105 Configure Ports Screen for IP MI Se rver .............................................................................. ..... 84 Figure 106 Conf igure Outlet Port Sc reen .......................................................
F IGURES ix Figure 158 Generate Certific ate Signing Req uest Sc reen ....................................................................... 132 Figure 159 Certificat e Reques t Generat ed..............................................................
x F IGURES Figure 211 Confi guration Settings Device Settings Screen...................................................................... 174 Figure 212 Confi guration Settings Device Settings Screen...................................................
F IGURES xi Figure 264 Selecting Network Interface Conf iguration ........................................................................... .. 209 Figure 265 Editing Ne t work Inte rfaces .............................................................
.
C HAPTER 1: I NTRODUCTION 1 Chapter 1: Introduction Congratulations on your purchase of Co mmandC enter Secure Gateway (CC-SG), Raritan’s convenient and secure method for managing various UNIX servers, firewalls, routers, load balancers, Power Management devices, and Windows servers.
2 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Product Features and Benefits • Seamless Management CC-SG offers seamless management of Dominion series and Paragon ® management appliances.
C HAPTER 1: I NTRODUCTION 3 • Comprehensive Logging − Logs events locally. − Can use an external syslog server for even t logs (events are immediately posted or exported) and the ability to have other Ra ritan products use it as a syslog server.
4 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE • CIM (Computer Interface Module)—is the hardware used to connect a target server and a Raritan device. Each target requires a CIM, except for the Dominion KX101 which is attached directly to one target and therefore, does not require a CIM.
C HAPTER 1: I NTRODUCTION 5 • Ports —are connection points between a Raritan Device and a target system or server. Or, a port can be a device that is directly connected to a LAN/CC-SG via In-band access. In CC- SG, you click on a port to access and manage th e target.
6 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE New 3.0 Features These administrator features are now available in CC-SG 3.0: Note : If viewing a PDF file, click on the page number to navigate to the location i n the document where the feature is described.
C HAPTER 2: A CCESSING CC-SG 7 Chapter 2: Accessing CC-SG Once you have configured CC-SG with an IP address and have defined at least one user, as described in Raritan’s CommandCenter Secure Gateway Setup Guide , the CC-SG unit can be placed at its final destination.
8 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE 2. You will be warned if you are using an unsupported Java Runtim e Environment version on your machine.
C HAPTER 2: A CCESSING CC-SG 9 Standalone Client Access The standalone CC-SG client allows you to co nnect to CC-SG servers by launching a Java application instead of running an applet through a Web browser. 1. Install the standalone CC-SG client lo cated on the included CD ROM onto your PC.
10 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE 3. Click Update Configuration to submit the changes. A confirmation window asks if you wish to restart CC-SG in order to apply changes. 4. Click OK to log out from your current session and restart CC-SG.
C HAPTER 2: A CCESSING CC-SG 11 2. Select an application from the pull-down menu and note the number in the version field. If the firmware needs upgrading, see the previous section Check and Upgrade CC-SG Firmware Version and continue to step 3. 3. Select the application name that needs to be upgraded.
12 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE To access a remote target device that is connected via a serial port, click on the appropriate device in the Devices selection tree, under the Devices tab.
C HAPTER 2: A CCESSING CC-SG 13 Power Down CC-SG If running CC-SG on the V1 platform and if it loses AC power while it is up and running, the V1 unit remembers its last power state.
14 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Note: To make ports easier to find, right-click on the tree and select the desired listing method under Port Sorting Options .
C HAPTER 2: A CCESSING CC-SG 15 Main Window Components Figure 13 CC-SG Application Window The CC-SG menu bar displays all operations and configuration commands. Active commands are based upon the privileges of the user, as establis hed by the CC-SG Administrator.
16 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Configuring CC-SG Manager Components In order to use CC-SG effectively, you must co mplete the following configuration steps, as described in this and the next chapter: • Configure and install Dominion series and IP-Reach appliances (both serial and KVM devices).
C HAPTER 2: A CCESSING CC-SG 17 Compatibility Matrix The Compatibility Matrix lists the firmware versi ons of Raritan devices and software versions of applications that are compatible with the curre nt version of CC-SG. To view the Compatibility Matrix, on the Devices menu, click Compatibility Matrix .
18 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE.
C HAPTER 3: E XAMPLE C ONFIGURATION W ORKFLOW 19 Chapter 3: Example Configuration Workflow Create Associations The Association Wizard guides you t hrough steps to create categories and their associated elements. Th e Wizard then automatically creates a por t group for each element and a policy for each port group.
20 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE 2. After reading the overview, click Next . The Create Category and Elements screen of the Wizard appears. Figure 16 Association Wizard - Category and Elements Screen 3. Type the name of a category you wish to organize your ports by (for example: Location ) in the Category field.
C HAPTER 3: E XAMPLE C ONFIGURATION W ORKFLOW 21 5. To create another category, click Add Another Category and repeat steps 3 and 4. To review categories and elements you have created, click Previous or Next to cycle through them. Figure 17 Adding Another Category 6.
22 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE 8. CC-SG will show a progress bar while it is crea ting the associations, port groups and policies. When this is complete, the Association Wizard Summary screen appears displaying the list what was created.
C HAPTER 3: E XAMPLE C ONFIGURATION W ORKFLOW 23 4. Click Next to proceed. The Add Device description screen appears. Depending on the type of device you selected, you will see slightly different Add Device screens. Figure 21 Add Device PowerStrip Figure 22 Add Device SX 5.
24 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Device Created successfully message confirms that device has be en added. This step is very important. Make sure you select the correct asso ciations and elements for the device. Some devices such as SX may take up to a minute to add.
C HAPTER 3: E XAMPLE C ONFIGURATION W ORKFLOW 25 3. Click Configure next to the serial port line item you wish to configure. The Configure Serial Port screen appears. Figure 24 Configure Serial Ports 4. Type a port name in Port Name field. Typically, you should name the port after the target server the device connects to, for example, NYC_MsSrv1 .
26 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE KVM Port 1. Click on the Devices tab and select a KVM device, for example, Dominion KX, from the Devices tree. 2. On the Devices menu, click Port Manager , and then click Configure Ports . Alternatively, you can right-click on the device and select Configure Ports .
C HAPTER 3: E XAMPLE C ONFIGURATION W ORKFLOW 27 5. Click on the Application Name drop-down menu and select name. This application, for example, Raritan Remote Console (RRC), is used to manage the target s ystem. All ports should use RRC except for those on an SX.
28 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE 5. If using local authentication, ty pe the new password into the Password field (6-16 character s, alphanumeric characters and underscores). 6. If using local authentication, re-type password in Retype Password field.
C HAPTER 3: E XAMPLE C ONFIGURATION W ORKFLOW 29 2. On the Users menu, click Add User Group . Alternatively, right-c lick on a user group and select Add User Group . The Add User Group screen appears. Figure 28 Add User Group Scree n 3. Type the group nam e in the User Group Name field (1-16 characters, alphanumeric characters and underscores).
30 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Create/Edit Port Groups CC-SG uses port groups to control user access. Po licies can be applied to specific user groups that allow only access to those ports specified in the port group.
C HAPTER 3: E XAMPLE C ONFIGURATION W ORKFLOW 31 6. If needed, enter the Boolean logic to apply additional rules in the Validate panel. Example: use (Rule0 & Rule1) for AND or use (Rule0 | Rule1) for OR. Additional combinations can be used. 7. Click Validate then Update .
32 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Sundays, and Custom to manually choose the days policy to be applied. If you choose Custom, check on the days of the week to apply the policy. 9. Click on a Permission value to select a permission type: Deny, or Control .
C HAPTER 3: E XAMPLE C ONFIGURATION W ORKFLOW 33 6. Click OK to add the policy or policies to the group. A Group Policies Updated successfully message confirms that policies have been updated. 7. Repeat steps 1 through 6 to edit other groups ’ policies.
34 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE 12. Type an email address for this user in the Email Address field, if desired. 13. Click OK to add this user to the system. A User Crea ted successfully message indicates the user has been added to the system.
C HAPTER 4: C REATING A SSOCIATIONS 35 Chapter 4: Creating Associations Associations CC-SG provides powerful, highly customizable organizational capabilities. Associations provide this organizational capability and are used to or ganize your equipment.
36 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Other examples of typical Association configura tions of Category and Elem ents are as follows: C ATEGORY E LEMENTS Location New York City, P.
C HAPTER 4: C REATING A SSOCIATIONS 37 • Devices —are Raritan products such as Domi nion KX116, Dominion SX48, Dominion KSX440, IP-Reach, Paragon II System Controller, Paragon II UMT832 with USTIP, etc. that are managed by CC-SG. These devices control the target servers and sy stems that are connected to them.
38 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Add Category 1. On the Associations menu, click Association Manager . The Association Manager screen appears. Figure 36 Association Manager Screen 2. Click Add in the Category panel to add a new category.
C HAPTER 4: C REATING A SSOCIATIONS 39 Edit Category 1. On the Associations menu, click Association Manager . The Association Manager screen appears. 2. Click on the Category Name drop-down arrow and select the category to be edi ted. 3. Click Edit in the Category panel of the screen to edit the category.
40 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Add Element 1. On the Associations menu, click Association Manager. The Associations Manager screen appears. Figure 40 Association Manager Screen 2. Click Add in the Element for Category panel to add a new element.
C HAPTER 4: C REATING A SSOCIATIONS 41 Edit Element 1. On the Associations menu, click Association Manager. The Association Manager screen appears. 2. Select the element to be edited from the Element For Category list and click Edit in the Elements For Category panel.
42 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Association Wizard The Association Wizard guides you t hrough steps to create categories and their associated elements , as described in the Association Manager section above, then automates the creation of related Port Groups and Policies for those elements.
C HAPTER 4: C REATING A SSOCIATIONS 43 5. If you wish to create another category, click Add Another Category and repeat steps 3 and 4. Figure 46 Adding Another Category 6. When you are done creating categories, click Next at the bottom of the screen. The Confirm Choices screen of the Wizard appears.
44 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE 8. CC-SG will show a progress bar while it is crea ting the associations, port groups and policies. When this is complete, the Association Wizard Summary screen appears displaying the list what was created.
C HAPTER 4: C REATING A SSOCIATIONS 45 Import Categories, Devices, Ports from CSV File To expedite configuration, you can import pre-de fined categories, elements of those categories, and the ports and devices to which the categories apply from a CSV file.
46 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE CSV File Format The entries in the CSV file are case-sensitive and each row in the CSV file has this format: {tag},{value}[,{value},….
C HAPTER 4: C REATING A SSOCIATIONS 47 Once successfully imported, yo u should see so mething like: Figure 50 Analysis Report Screen If necessary, refer to Appendix F: Troubleshooting for problem resolution.
48 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE.
C HAPTER 5: ADDING DEVICES AND DEVICE G ROUPS 49 Chapter 5: Adding Devi ces and Device Groups Device Manager Device Manager commands allow you to configur e Dominion series and IP-Reach units and their individual ports. From a CC-SG perspective, conn ection to a remote target device is made via a serial or KVM port.
50 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Device Icons I CON M EANING Device available Port available KVM port connected – in current user session Port paused – because device is .
C HAPTER 5: ADDING DEVICES AND DEVICE G ROUPS 51 Add Device Use this command to add a new device to the system. 1. Click on the Devices tab. 2. On the Devices menu, click Device Manager , and then click Add Device . The Add Device selection screen appears.
52 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Figure 54 Add Device Screen for Raritan Devices Figure 55 Add Device Screen for iLO, RILOE.
C HAPTER 5: ADDING DEVICES AND DEVICE G ROUPS 53 Figure 56 Add Device Screen for IPMI Server (v 1.5) Figure 57 Add Device Screen for Generic Device 5. Type the new device name in the Device name field. 6. Type the IP Address or Hostname of the new device in the Device IP or Hostname field.
54 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE KX Devices with Encryption CC-SG supports adding and ma naging Dominion KX devices, such as KX101, that have been configured with: • SSL au.
C HAPTER 5: ADDING DEVICES AND DEVICE G ROUPS 55 Delete Device 1. Click on the Devices tab and select a device from Devices tree. 2. On the Devices menu, click Device Manager , and then click Delete Device . The Delete Device screen appears. Figure 59 Delete Device Screen 3.
56 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Backup Device C onfiguration Use this command to back up all user configura tion and system configuratio n files. If anything happens to your system, you can restore your previous configuratio ns from memory.
C HAPTER 5: ADDING DEVICES AND DEVICE G ROUPS 57 Copy Device Configuration This command allows you to copy configurations from one device to another or multiple devices. Note: Configuration can only be copied between Dominion SX units and DSX units that have the same number of ports.
58 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE If the firmware version of the device is not co mpatible with CC-SG, a message will alert you and ask if you want to proceed (please see Chapter 2: Accessing CC-SG for additional information).
C HAPTER 5: ADDING DEVICES AND DEVICE G ROUPS 59 Pause Device You can pause a device to temporarily suspend CC-SG’s control of it without losing an y of the configuration data stored within the CC-SG Server. 1. Click on the Devices tab and select a device from the Devices tree.
60 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Custom View You can customize the Devices tree by organizing devices to appear in a particular format. You might want to view devices by Country, by Time Zone, or by any other option that helps you differentiate between them.
C HAPTER 5: ADDING DEVICES AND DEVICE G ROUPS 61 Add Custom View 1. Click on the Devices tab. 2. On the Devices menu, click Change View, and then click Custom View . The Custom View screen appears. 3. In the Custom View panel, click Add . An Add Custom View window appears.
62 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE 5. In the Custom View Details panel, click on the drop-down arrow at the bottom of the panel. This list contains categories that you can use to filter custom views. Select a detail from the drop-down list and click Add to add the detail to t he Custom View Details panel.
C HAPTER 5: ADDING DEVICES AND DEVICE G ROUPS 63 Topological View Use the Topological View command to view the structural setup of all the connected appliances in your configuration. 1. Click on the Devices tab and select a device from the Devices tree.
64 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Special Access to Paragon II System Devices Paragon II System Controller (P2-SC) Paragon II System Integration users can add thei r P2-SC devices to the CC-SG Devices tree and configure them via the P2-SC Admin application from within CC-SG.
C HAPTER 5: ADDING DEVICES AND DEVICE G ROUPS 65 IP-Reach and UST-IP Administration You can also perform administrative diagnosti cs on IP-Reach and UST-IP devices connected to your Paragon System setup directly from the CC-SG interface. After adding the Paragon System device to CC-SG, it appears in the Devices tree.
66 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Device Power Manager Before using the Device Power Manager view, make a physical connection of a PowerStrip to a Dominion SX or Dominion KSX unit. When you add the PowerStrip device, define this connection in CC-SG.
C HAPTER 5: ADDING DEVICES AND DEVICE G ROUPS 67 Discover Devices Use this command to initiate a search for all devices on your system. The search will automatically detect all newly attached, and prev iously existing Raritan devices on your network, including Paragon, P2-SC, IP-Reach, Dominion KX, Dominion KSX units, IPMI servers, and CC-SGs.
68 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE 7. Select a device from the list and click Add to add the device to CC-SG or click Close to exit without adding the device. If you clicked Add , the Add Device screen appears. Figure 81 Add Device Screen 8.
C HAPTER 5: ADDING DEVICES AND DEVICE G ROUPS 69 Device Group Manager Use the Device Groups Manager screen to add, edit, assign, and remove device groups and the rules that govern them. First add a Device Group, then add a Device Rule(s) to make working with and viewing devices easier.
70 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Edit Device Group Name 1. On the Associations menu, click Groups Manager , and then click Device Group Manager . The Device Group Manager screen appears. Figure 84 Device Groups Manager Screen 2.
C HAPTER 5: ADDING DEVICES AND DEVICE G ROUPS 71 Delete Device Group 1. On the Associations menu, click Groups Manager , and then click Device Group Manager . The Device Groups Manager screen appears. Figure 86 Device Groups Manager Screen 2. Click on the Group Names drop down arrow and select the de vice group to be deleted.
72 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Important: You can combine the applicati on of two or more rules by using operators such as ‘&’ meaning ‘and’ or ‘ ⎜ ’ (vertical ba r that shares the <> key on your keyboard) meaning ‘or.
C HAPTER 5: ADDING DEVICES AND DEVICE G ROUPS 73 Search for Devices CC-SG can search for a device name that satisfies the text entered in the search box. Searches are case-insensitive. 1. Click on the Devices tab. Figure 91 Search for Devices 2. At the bottom of the window, enter a search string in Search For Device .
74 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Examples are as follows: E XAM PLE D ESCRIPTION KX? Locates KX1, and KXZ, but not KX1Z . KX* Locates KX1, KX, KX1, and KX1Z . KX[0-9][0-9] T Locates KX95T, KX66T, but not KXZ and KX5PT . Disconnect Users Administrators can terminate any user's sessi on with a device.
C HAPTER 6: C ONFIGURING P ORTS AND P ORT G ROUPS 75 Chapter 6: Configuring Ports and Port Groups This chapter discusses how to configure and edit ports and port groups.
76 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE When you click on the Ports tab, the Ports tree displays information ab out the Ports connected with CC-SG. Clicking on a port causes the View Port screen to appear. Ports are arr anged alphabetically by name, or grouped by availability status.
C HAPTER 6: C ONFIGURING P ORTS AND P ORT G ROUPS 77 Port Icons For easier identification, different ports have diffe rent icons in the tree. In addition, availability status of each port also has a different icon. Fo r a description of what the icons represent, please see the table below.
78 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Configure Port Configure a Serial Port Click on the Devices tab and select a serial device from the Devices tree. 1. On the Devices menu, click Port Manager , and then click Configure Ports . The Configure Ports screen appears.
C HAPTER 6: C ONFIGURING P ORTS AND P ORT G ROUPS 79 3. Click the Configure button that corresponds to the se rial port line item you wish to co nfigure. The Configure Serial Port screen appears. Figure 95 Configure Serial Ports Screen 4. Type a port name in Port Name field.
80 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE 11. Click In-Band Parameters if you want to allow in-ba nd access for this Serial port. Figure 97 In-Band Parameters 12. Click on the In-band application drop-down arr ow and select either RemoteDeskto p Viewer , SSH Client , VNC Viewer .
C HAPTER 6: C ONFIGURING P ORTS AND P ORT G ROUPS 81 Configure a KVM Port 1. Click on the Devices tab and select a KVM device from the Devices tree. 2. On the Devices menu, click Port Manager , and then click Configure Ports . The Configure Ports screen appears.
82 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE 5. Type a port name in the Port Na me field. For ease of use, you should nam e the port after the server that is connected to the port.
C HAPTER 6: C ONFIGURING P ORTS AND P ORT G ROUPS 83 Configure a Generic Port with In-Band Access In-band access to Generic devices, such as hubs , Windows servers, CISCO routers, can be managed with one of th ese in-band applications: • Windows Remote Desktop (RDP) • Secure Shell (SSH) • Virtual Network Computer (VNC) 1.
84 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE 7. Type a Target Username that the application will use as a Start-up parameter. If a target name is supplied, then only a password is required when accessing a target. 8. Select the associated category and element from the Port Associations table.
C HAPTER 6: C ONFIGURING P ORTS AND P ORT G ROUPS 85 3. Click the Configure button that corresponds to the outlet port line item you wish to configure. A Configure Outlet Port screen appears. Figure 106 Configure Outlet Port Screen 4. Type the port name in the Port Name field.
86 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Delete Ports Delete a port to remove the port entry from the Ports tree and Cancel all accessibility of the remote target device. 1. Click on the Ports tab and select a port to be deleted. 2. On the Devices menu, click Port Manager , and then click Delete Port .
C HAPTER 6: C ONFIGURING P ORTS AND P ORT G ROUPS 87 Bulk Copy To save time, use the Bulk Copy co mmand to duplicate Port names or associations to other ports. 1. Click on the Ports tab and select a port whose data you want to copy to another. 2. On the Ports menu, click Bulk Copy .
88 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Edit Port Edit a Serial Po rt 1. Click on the Ports tab and select a serial port to be edited. 2. On the Ports menu, click Edit Port . The Edit Serial Port screen appears. Figure 109 Edit Serial Port Screen 3.
C HAPTER 6: C ONFIGURING P ORTS AND P ORT G ROUPS 89 Edit a KVM Port 1. Click on the Ports tab and select a KVM port to be edited. 2. On the Ports menu, click Edit Port . The Edit KVM Port screen appears. Figure 110 Edit KVM Port Screen 3. Type a new port name in the Port Name field.
90 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Edit a Generic Port 1. Click on the Ports tab and select a Generic port to be edited. 2. On the Ports menu, click Edit Port . The Edit Generic Port screen appears. Figure 111 Edit Generic Port Screen 3.
C HAPTER 6: C ONFIGURING P ORTS AND P ORT G ROUPS 91 Port Group Manager Add Port Group 1. On the Associations menu, click Groups Manager and then click Port Group Manager . The Port Groups Manager screen appears. Figure 112 Port Groups Manager Screen 2.
92 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Edit Port Group 1. On the Associations menu, click Groups Manager and then click Port Group Manager . The Port Groups Manager screen appears. 2. Click on the Group Name drop-down arrow and select a group to edit.
C HAPTER 7: A DDING U SERS AND U SER G ROUPS 93 Chapter 7: Adding Users and User Groups User Manager commands are listed in the Users menu and allow you to define the CC-SG user list and assign user privileges for performing vari ous functions. CC-SG maintains a centralized user access list.
94 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE 8. Check the Force Change Password on Next Login check box if you want this user to be forced to change password the next time he or she logs in to CC-SG.
C HAPTER 7: A DDING U SERS AND U SER G ROUPS 95 5. Check the Force Change Password Periodically check box if you want th is user to have to change his or her password from time to time and specify an expiration period for this user’s password in the Expiration Period field.
96 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE 2. Type your old password in the Old Password field. 3. Type your new password in the Password field. You cannot re-use your old password. 4. Re-type your password in the Retype Password field.
C HAPTER 7: A DDING U SERS AND U SER G ROUPS 97 Logoff User(s) Use this command to disconnect any logged-in user from CC-SG. 1. Click on the Users tab and select a user from the Users tree. Note : To select more than one user, hold the CTRL key and click on additional users.
98 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Bulk Copy To save time, use the Bulk Copy command to dupl icate user profiles or port assign ments when creating new users. 1. Click on the Users tab and select a user from the Users tree whose properties you want to copy to another user(s).
C HAPTER 7: A DDING U SERS AND U SER G ROUPS 99 Add User to Group To manage users with similar privileges, you can assign them to groups. When you add a user to any group, you are assigning the group’s privile ges to that user (please see the section Add User Group in this chapter for more information about groups).
100 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Add User Group Use the Add User Group command to create specific groups and assign them different privileges, depending on the needs of your work enviro nment. Groups can help you keep y our system organized.
C HAPTER 7: A DDING U SERS AND U SER G ROUPS 101 Edit User Group This command allows you to rename group and modify its Features. Important: Please remember that you must be an Administrator to modify User Groups. The category Users Not In Group c annot be modified.
102 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Apply (Edit) User Group Policies Groups can be assigned policies, or permissions, that allow them to view and/or control devices and ports. Depending on which policies are assi gned to them , groups might have: No Rights, Some Rights, Control Rights, or Full Adm inistration Rights.
C HAPTER 7: A DDING U SERS AND U SER G ROUPS 103 Delete User Group This command allows you to remove a group na me from the system. Users from the deleted group will be re-assigned to the category Users Not In Group , displayed at the base of the Users tree.
104 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE 6. Click OK to assign users to the group or Cancel to exit without saving. A Users Assigned Successfully message confirms that users have been assigned. 7. Repeat steps 1 through 6 to assign users to other groups.
C HAPTER 7: A DDING U SERS AND U SER G ROUPS 105 Supported Wildcards These wildcards are supported: W ILDCARD D ESCRIPTION ? Indicates any character. [-] Indicates a character in range. * Indicates zero or more char acters. Example: E XAM PLE D ESCRIPTION root? Locates root1, and root N, but not root 1N .
106 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE.
C HAPTER 8: C REATING P OLICIES 107 Chapter 8: Creating Policies Controlling User Access with Policies Using policies to control user access to ports is entirely optional.
108 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE User Groups User groups are used to define a group of user s and CC-SG privileges they pos sess. When a user logs on, they will see the CC-SG interface. The user group privileges define what the user can do with CC-SG.
C HAPTER 8: C REATING P OLICIES 109 Policies Policies define what you can do, what you can do it to, and when you can do it. Policies allow specification of days and times, port/device access, and if it was granted control access (Read/Write), or deny access (None).
110 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Policy Manager Policy Manager commands allow you to add, edit, delete, and assign policies to Device and Port groups. Policies give users rights to allow or deny access to groups. Please see Appendix C: Initial Setup Process Overview for more information on using policies.
C HAPTER 8: C REATING P OLICIES 111 10. Click Update to add the policy. The Update Policy window appears Figure 134 Update Policy Window 11. Click Yes to add the policy or No to close the window. 12. Click Close to close the Policy Manager screen. 13.
112 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Delete Policy 1. On the Associations menu, click Policy Manager . The Policy Man ager screen appears. 2. Click on the Name drop-down arrow to select a po licy to be deleted. Click Delete to delete the policy.
C HAPTER 9: C ONFIGURING R EMOTE A UTHENTICATION 113 Chapter 9: Configuring Remote Authentication Authentication and Authorization Users of CC-SG can be locally authenticated and authorized on the CC-.
114 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Establish Order of Authentication Databases The General properties allow you to set the orde r of your authentication databases. If the first checked option is unavailable, CC-SG will try the second, then the third, and so on, until it is successful.
C HAPTER 9: C ONFIGURING R EMOTE A UTHENTICATION 115 Base DN You also enter a Distinguished Name (DN) to sp ecify where the search for users begins. Enter a DN in the Base DN field to specify an Active Directory c ontainer in which the users can be found.
116 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE 2. On the Active Directory server, set up your users under the Users organizational unit (ou).
C HAPTER 9: C ONFIGURING R EMOTE A UTHENTICATION 117 Setup on CC-SG 1. On CC-SG, click Security Manager from the Setup menu. When the Security Manager screen appears, click Add External AA Server . 2. In the Add Module screen, select AD from the Module Type pulldown m enu.
118 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE General Settings on CC-SG 1. Type the IP Address/Hostname of the Active Directory server. For hostname rules, se e Terminology/Acronyms in Chapter 1: Introduction . Figure 143 Specifying General Values for Active Directory Server 2.
C HAPTER 9: C ONFIGURING R EMOTE A UTHENTICATION 119 Advanced Settings on CC-SG 1. If you want to configure adva nced settings, click on the Advanced tab. Figure 144 Specifying Advanced Values for Active Directory Server 2. Specify a port (default is 389 ) on which the Active Directory server is listening.
120 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE 5. Specify a Base DN (directory level/entry) under which the authentication search query will be executed. E XAM PLE D ESCRIPTION dc=raritan,dc=com The search query for the user entry will be made over the whole directory structure.
C HAPTER 9: C ONFIGURING R EMOTE A UTHENTICATION 121 Group Settings on CC-SG Use to retrieve groups from the AD server and import into CC-SG local database for authorization purposes. 1. Click on the Groups tab. Figure 145 Specifying Group Values for Active Directory Server 2.
122 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE 5. On CC-SG, in the Security Manager screen, click Import Groups… to retrieve a list of us er group values stored on the Active Directory server. If any of the user groups are not already on the CC-SG, you can import them here and assign them an access policy.
C HAPTER 9: C ONFIGURING R EMOTE A UTHENTICATION 123 10. Verify the policy of the group that was imported by clicking the Users tab, right-clicking on the group and selecting Edit User Group Policies . Look under Selected Policies to confirm the policy that the correct policy was assigned to the group.
124 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE LDAP (Netscape) Once the CC-SG applet is started and a user name and password are entered, a query is forwarded either through CC-SG or directly to the LDAP server. If the username and password match those in the LDAP directory, the user is authenticated.
C HAPTER 9: C ONFIGURING R EMOTE A UTHENTICATION 125 2. In Add Module screen, select LDAP from the pulldown menu, specify a name for the server, and click Next . Figure 151 Security Manager LDAP Screen Gen eral Tab 3. Type the IP address or hostname of the LDAP server in the IP Address/Hostname field.
126 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE 11. Click Test Connection to test the LDAP server using the given parameters. You sho u ld receive a confirmation of a successful connection. If not, review the settings carefully for errors and try again.
C HAPTER 9: C ONFIGURING R EMOTE A UTHENTICATION 127 Sun One LDAP (iPlanet) Configuration Settings If using a Sun One LDAP server for remote auth entication, use this example for parameter settings: P.
128 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE TACACS+ CC-SG users who are remotely authenticated by a TACACS+ server need to be created on the TACACS+ server and on CC-SG. The user’s user name on the TACACS+ server and on CC-SG must be the same, although the passwords may be different.
C HAPTER 9: C ONFIGURING R EMOTE A UTHENTICATION 129 2. In the Add Module screen, select TACACS+ from the pulldown menu, specify a name fo r the server, and click Next . Figure 154 Specifying a TACACS+ Server 3. Type the IP address or hostname of the TACACS+ server in the IP Address/Hostname Name field.
130 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE RADIUS CC-SG users who are remotely authenticated by a RADIUS server need to be created on the RADIUS server and on CC-SG. The u ser’s u ser name on the RADIUS server and on CC-SG must be the same, although the passwords may be different.
C HAPTER 9: C ONFIGURING R EMOTE A UTHENTICATION 131 3. Type the IP address or hostname of the RADIUS server in the IP Address/Hostname field. For hostname rules, see Terminology/Acronyms in Chapter 1: Introduction . 4. Type the port number in the Port Number field.
132 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Generate Certificate Signing Request The following explains how to generate a CS R and a private key on CC-SG. The CSR will be submitted to the Certificate Server who will issue a signed certificate.
C HAPTER 9: C ONFIGURING R EMOTE A UTHENTICATION 133 11. Type raritan in the Password field if the CSR was generated by CC-SG. If a different application generated the CSR, use that password for that application.
134 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE IP-ACL This feature restricts access to CC-SG based on IP addresses. Specify an IP-access control list (IP-ACL) by entering an IP address range, the grou p to which it applies, and an Allow/Deny privilege.
C HAPTER 10: G ENERATING R EPORTS 135 Chapter 10: Generating Reports Reports can be sorted by clicking on the column headers. Click on a column header such as User Name, Access Time, etc., to sort report data by that value. The data will refresh in ascending order alphabetically, numerically, or chronolo gically.
136 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE 3. Click Manage Report Data… to save or print the report. Click Save to save the report to a location of your choice or Print to print the report. Figure 163 Manage Report Wi ndow 4. Click Close to close the Manage Report window.
C HAPTER 10: G ENERATING R EPORTS 137 Asset Management Report The Asset Management report displays data on current devices. 1. On the Reports menu click Asset Management Report . The Asset Management report is generated. Figure 165 Asset Management Report 2.
138 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Audit Trail Report The Audit Trail report displays audit logs and access in CC-SG. It captures actions such as adding, editing, or deleting devices or ports, and other m odifications.
C HAPTER 10: G ENERATING R EPORTS 139 6. The Audit Trail report is generated, displaying data about sessions that occur red during the designated time period.
140 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Error Log Report CC-SG stores error messages in a series of Error Log files, which can be brought up and used to help troubleshoot system problems. You can filter the search criteria by date, message ty pe, username, class, host, and level.
C HAPTER 10: G ENERATING R EPORTS 141 6. The Error Log report is generated, displayi ng data about sessions that occurred during the designated time period. Figure 169 Error Log Repo rt 7. Click Manage Report Data… to save or print the report. Click Save to save the records that are displayed to a CSV file or click Save All to save all record s.
142 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Ping Report The Ping Report displa ys the status of all connec tions, showing devices by name and IP address. This report gives you the full accessibility picture for all devices on your system, and will supply information that could be useful in case troubleshooting is necessary.
C HAPTER 10: G ENERATING R EPORTS 143 Accessed Devices Report Run the Accessed Devices report to view inform ation about any accessed devices, when they were accessed, and the user who accessed them. Filte rs will help you define the search criteria for a more concise report.
144 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE 5. Click OK to run the report. Figure 172 Accessed Devices Report 6. The Accessed Devices report is generated, disp laying data about devices accessed during the designated time period. 7. Click Manage Report Data… to save or print the report.
C HAPTER 10: G ENERATING R EPORTS 145 Group Data Report The Group Data report displays user, port, and de vice Group information. View user groups by name and description, view port groups by nam e , and view device groups by name, all in one screen. 1.
146 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE User Data Report The User Data report displays certain data on all users in the CC-SG database. From User Name field you can see names of users currently in sessi on and view details of users currently not in session.
C HAPTER 10: G ENERATING R EPORTS 147 Users In Groups Report The Users In Group report displays data on users and the groups with which they are associated. 1. On the Reports menu, click Users In Groups . The Users In Groups report is generated. Use the scroll bar to scroll through the list and view all entries.
148 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Query Port Report The Query Port Report displays all ports according to port status. 1. On the Reports menu, click Query Port . The Query Port screen appears. Figure 176 Query Port Report 2. Click on one or more checkboxes to custom i ze the port information you want to see in the report.
C HAPTER 10: G ENERATING R EPORTS 149 View Stored Reports The View Stored Reports displays reports that were scheduled in the Task Manager see section Task Manager in Chapter 12: Advanced Administration . 1. On the Reports menu, click View Stored Reports .
150 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Locked Out Users Report The Locked Out Users report displays users w ho are currently locked out of CC-SG. You can unlock them from this report. 1. On the Reports menu, click Locked Out Users .
C HAPTER 10: G ENERATING R EPORTS 151 CC-NOC Synchronization Report The CC-NOC Synchronization report lists all target s, along with their IP addresses, that the CC- SG subscribes to and are monitored by a CC-NOC given a particular discovery date. Any new targets that are discovered in the configur ed range are displayed here as well.
152 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE.
C HAPTER 11: S YSTEM M AINTENANCE 153 Chapter 11: System Maintenance Reset CC-SG Use the Reset CommandCenter comma nd to reset CC-SG database data – please note that this command will not reset system configuration data, such as the IP address of CC-SG.
154 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Restore CC-SG 1. On the Setup menu, click Restore CommandCenter. 2. When the Restore CommandCenter screen appears, choose if you want to click on the backup that you want to restore to your CC-SG unit, and then click OK .
C HAPTER 11: S YSTEM M AINTENANCE 155 Saving and Uploading Backup Files You can also save and load CC-SG backups to and from you r local PC using the Restore CommandCenter screen. 1. Click on the backup you wish to save to your PC, an d then click Download.
156 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Refresh CC-SG Display Any edits or modifications made to users, ports, categories, elements, and other system components are not reflected in the system until the database is updated.
C HAPTER 11: S YSTEM M AINTENANCE 157 Upgrade CC-SG Note: If you are operating a CC-SG cluster, you mu st remove the cluster first and upgrade each node separately.Before you can upgrade CC-SG, y ou must be in Maintenance Mode. See section Maintenance Mode in Chapter 11: System Maintenance for additional information.
158 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE 5. Click OK to restart CC-SG or Cancel to exit the screen without restarting. Once y ou restart CC-SG, your Broadcast Message appears. Figure 187 Info Window 6. Click OK to restart CC-SG. 7. CC-SG will restart, and is ready for use.
C HAPTER 11: S YSTEM M AINTENANCE 159 End CC-SG Session Log Out To exit CC-SG at the end of a session, or to refr esh t he database in case y ou or another user has made changes while you were logged in, log off from CC-SG entirely, then log in again.
160 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Scheduled Tasks Scheduled tasks cannot execute while CC-SG is in Maintenance Mode ─ please see section Task Manager in Chapter 12: Advanced Administration for additional information on scheduled tasks.
C HAPTER 12: ADVANCED ADMINISTRATION 161 Chapter 12: Advanced Administration Configuration Manager Network Configuration 1. On the Setup menu, click Configuration Manager . When the Configuration Manager screen appears, click on the Network Setup tab.
162 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE A. Choose Primary/Backup mode to implement network fa ilover and redundanc y. In this mode, only one NIC is active at a give n point of time and only one network IP address assignment is possible.
C HAPTER 12: ADVANCED ADMINISTRATION 163 In this mode, CC-SG acts as a “router” or “traffic cop” between two separate IP domains; particularly when Proxy mode is being used (please see Connection Mode, later in this chapter, for additi onal information).
164 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE 3. Click on the Level to Forward drop-down arrow to select a level. 4. Repeat steps 2 and 3 for Secondary Server fields (note that Secondary Server is optional). 5. Click Update Configuration to save the server addresses to the system.
C HAPTER 12: ADVANCED ADMINISTRATION 165 Time/Date Configuration CC-SG’s Time and Date stamps must be accurately maintained in order to provide credibility for its device-management capabilities. Important! This time is used when scheduling tasks in Task Manager ⎯ see section Task Manager in Chapter 12: Advanced Administratio n.
166 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Modem Configuration Use this screen to access CC-SG from a client machin e over a dial-up connection. This method of accessing CC-SG can be used in emergency situations. Note : A modem is not available and cannot be config ured on the V1 platform.
C HAPTER 12: ADVANCED ADMINISTRATION 167 4. Click on the Advanced tab. Figure 200 Extra Initialization Commands 5. Type an initialization command in Extra initialization commands that will be used by your modem to set the “Carrier detection” flag.
168 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE 4. Click Next . Figure 202 New Connection Wizard 5. Click Connect to the network at my workplace . 6. Click Dial-up connection . 7. Type a name for CC-SG, for example CommandCenter . Figure 203 Connection Name 8.
C HAPTER 12: ADVANCED ADMINISTRATION 169 10. In the next screen, typically you want to click My use only in the next screen to make the connection available only to yourself.
170 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE transmit "ccclient^M" endproc Connect to CC-SG with Modem To connect to CC-SG: 1. On the start menu, click My Network Places . 2. Click view network connections under Network Tasks .
C HAPTER 12: ADVANCED ADMINISTRATION 171 7. If Show terminal window was checked as described in section Configure the Call-back Connection earlier in this chapter, then a window sim ilar to the one below will be displayed: Figure 208 After Dial Terminal 8.
172 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Connection Mode When connected to a device, you have the option to pass data back and forth directly with that device ( Direct Mode ) or to route all the data through your CC-SG unit ( Proxy Mode ).
C HAPTER 12: ADVANCED ADMINISTRATION 173 iii. Click the Add button to add the Net Address and Mask to the screen. You may have to use the scroll bar on the right side of the screen to view the Add/Rem.
174 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Device Settings 1. On the Setup menu, click Configuration Manager. When the Configuration Manager screen appears, click on the Device Settings tab. 2. To update device Default Port, select a Devi ce Type in the table and double-click on the Default Port value.
C HAPTER 12: ADVANCED ADMINISTRATION 175 SNMP Simple Network Management Protocol allows CC-SG to push SNMP traps (event notifications) to an existing SNMP manager on the network. On ly a CC-SG Administrator trained in handling an SNMP infrastructure should configure CC-SG to work with SNMP.
176 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE System Log traps, which include notifications for th e status of the CC unit itself, such as a hard disk failure, and Application Log traps for notifications generated by eve n ts in the CC application, such as modifications to a user a ccount.
C HAPTER 12: ADVANCED ADMINISTRATION 177 Strong Password Rules Strong password rules require users to observe strict guidelines when creating passwords, which makes the passwords more difficult to guess and, in theory, more secure. Administrators can enable or disable this feature ⎯ see the previous section Configure Security .
178 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE 6. Type an email address in Lockout notification email so notific ation is sent to the address informing the recipient that lockout has occurred. If the field is blank, notificatio n is not sent.
C HAPTER 12: ADVANCED ADMINISTRATION 179 4. Click OK to add the new application or Cancel to close the window. If you clicked OK , a search window appears. Figure 218 Search W indow 5. Click on the Look In drop-down arrow and navigate to locat e the application in your system .
180 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE 6. Modify parameters in the Parameters panel and click the Update button in the Details panel of the screen. The parameters will be updated. 7. Click Close to close the Application Manager screen.
C HAPTER 12: ADVANCED ADMINISTRATION 181 2. Click Add to add a new firmware file. A search window appears. Figure 222 Search W indow 3. Click on the Look In drop-down arrow and navigate to lo cate the firmware file in your system. When you find the firmware, select it, and click Open .
182 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Add a CC-NOC Note : To create a valid connection, the time se ttings on both the CC-NOC and CC-SG should be synchronized. The best method of ach ieving this synchronization, it to use a common NTP (Network Time Protocol) server.
C HAPTER 12: ADVANCED ADMINISTRATION 183 3. Select a software version of CC-NOC you want to add and click Next . Versio n 5.1 has fewer integration features than 5.2 and only requ ires adding a name and an IP address. For additional information on CC-NOC 5.
184 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE To stop CC-NOC from monitoring a device, it can be unmanaged – see the CommandCenter NOC Administrator Guide . Note : Use the CC-NOC Synchronization Report to view targets that the CC-SG is subscribing to.
C HAPTER 12: ADVANCED ADMINISTRATION 185 Important: To increase security, you must enter the passcodes in CC-NOC within five minutes after they are gener ated on CC-SG. This will min i mize the window of opportunity for intruders to breach the system with a brute-force attack.
186 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE 2. Highlight a CC-NOC in the list and click Edit . The Edit CC-NOC Configuration screen appears. Figure 229 Edit CC-NOC Configuration Screen 3. Refer to the previous section Add a CC-NOC for field details.
C HAPTER 12: ADVANCED ADMINISTRATION 187 Delete a CC-NOC To remove and unregister a CC-NOC in CC-SG, do the following. 1. On the CommandCenter NOC menu, click Configuration . The CC-NOC Configuration screen appears. Figure 231 Delete CC-NOC Screen 2. Highlight a CC-NOC in the list and click Delete .
188 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Create a Cluster In the event of a failover, the administrator s hould send an email to all CC-SG users, notifying them to use the IP address of the “new” Primary CC-SG node.
C HAPTER 12: ADVANCED ADMINISTRATION 189 Set Secondary CC-SG Node 1. Click Discover Co mmandCenters to scan and display all CC-SG appliances on the same subset as your one you are currently using. Alternatively, you can add a CC-SG, perhaps from a different subnet, by specifying an IP address in CommandCenter address in the bottom of the window.
190 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Remove Secondary CC-SG Node 1. To remove Secondary Node status from a CC-SG unit and reassign it to a different unit in your configuration, select the Secondary CC-SG Node in the Cluster Configuration table and click Remove “Backup” Node.
C HAPTER 12: ADVANCED ADMINISTRATION 191 Set Advanced Settings To configure advanced settings of a cluster configuration: 1. Select the Primary node just created. 2. Click Advanced . The Advanced Settings window appears. Figure 236 Cluster Configur ation Advanced Settings 3.
192 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE • Outlet Port Power Management (Power On/Off/Recycle Outlet ports) • Generate all Reports (HTML or CSV formats) • Purge Logs Scheduling Sequential Tasks You may want to schedule tasks sequentially to confirm that expected behavior was actually carried out.
C HAPTER 12: ADVANCED ADMINISTRATION 193 Create a New Task To schedule a new task: 1. On the Setup menu, click Task Manager . Figure 237 Task Manager 2. Click New . Figure 238 Create Task 3. In the Main tab, type a name (1-32 characters, alphanumeric characters or underscores, no spaces) and description for the task.
194 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE 4. Click on the Task Data tab and from the pulldown menu, select the task to be scheduled, such as Upgrade Device Firmware . Note that the fields requiring data will vary according to the task selected.
C HAPTER 12: ADVANCED ADMINISTRATION 195 8. Change Own Password in Chapter 7: Adding Users and User Groups . If an email was not configured, then this field is blank. By defau lt, email is sent if the task was successful. To notify the recipient of failed tasks, click the On Failure checkbox.
196 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE 4. To view the history of a task, select a task and click Task History . Figure 243 Task History 5.
C HAPTER 12: ADVANCED ADMINISTRATION 197 Notification Manager Use Notification Manager to configure an extern al SMTP server so notifications can be sent from CC-SG.
198 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE SSH Access to CC-SG Use Secure Shell (SSH) clients, such as Putty or OpenSHH Client, to access a co mmand line interface to SSH (v2) server on CC-SG. Only a subset of CC-SG commands is provided via SSH to administer devices and CC-SG itself.
C HAPTER 12: ADVANCED ADMINISTRATION 199 4. A shell prompt appears. Type ls to display all commands available from SSH. Figure 248 CC-SG Commands via SSH 5.
200 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE 6. Typing the command with the –h switch displays help for that command, such as listfirmwares –h.
C HAPTER 12: ADVANCED ADMINISTRATION 201 Create a SSH Connection to an SX Device You can create an SSH connection to an SX de vice to perform adm inistrative operations on the device. Once connected, the administrative commands supported by the SX device are available.
202 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Connect to a Serial Port Connect to a serial port to access a target server. You can access serial ports on a SX, KSX, or IP- Reach device. The SSH connection to the serial ports are in proxy mode.
C HAPTER 12: ADVANCED ADMINISTRATION 203 3. Once connected to the port, type the default Escape key s of ‘ ~ ’ followed by a dot ‘ . ’. An intermediate prompt, typically named afte r port nam e, is display ed, for example testport> .
204 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Diagnostic Console The Diagnostic Console is a standard, non-grap hical interface that pr ovides local access to CC- SG. It can be accessed from a serial or KVM port, or from Secure Shell (SSH) clients, such as Putty or OpenSSH Client.
C HAPTER 12: ADVANCED ADMINISTRATION 205 Accessing Status Console Entering a password to access the Status Console is no t required, but can be enforced if desired. 1. After login as: , type status . Figure 256 Login to Status Console The read-only status console is displayed.
206 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Accessing Administrator Console At the time of logging into Administrator Console, all inform ation displayed is “static”.
C HAPTER 12: ADVANCED ADMINISTRATION 207 Navigating Adminis trator Console PRESS.. T O … CTRL+C or CTRL+Q To exit Diagnostic Console. CTRL+L Refresh screen and update information. TAB Move to next available option. SPACE Select current option. Arrow Keys Allows you to move to various options.
208 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE 3. Click Save as Default at the bottom of the screen or press the TAB key and press Enter once Save as Default is highlighted.
C HAPTER 12: ADVANCED ADMINISTRATION 209 Figure 263 Edit Status Console Config 3. Click Save at the bottom of the screen or press the TAB key and press Enter once Save is highlighted.
210 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE 2. If this is the first time accessing CC-SG and th e network interfaces have not been configured, it is strongly recommended to use CC-SG GUI to configure them instead of configuring them here.
C HAPTER 12: ADVANCED ADMINISTRATION 211 Ping an IP Address (Network Interfaces ) Use ping to check that the connection between your computer and a particular IP address (domain) is working correctly. 1. To ping an IP address or hostname, click Operation , Network Interfaces , then Ping .
212 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Using Traceroute (Network Interfaces ) Traceroute is often used for network troubleshooting. B y showing a list of routers traversed, it allows you to identify the path ta ken from your computer to reach a particular destination on the network.
C HAPTER 12: ADVANCED ADMINISTRATION 213 Active/Active network settings where each interface is attache d to a separate IP domain-see section Network Configuration in Chapter 12: Advanced Administration for additional information. Click with the mouse or use the TAB , ↓↑ keys to navigate and press the Enter key to select a value.
214 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE 2. Click with the mouse or use the ↓↑ keys to navigate and press the Enter key to select a log file (marked with an X) . More than one log file can be viewed at a time. (Some log files are not available; a warning dialog will appear and the item will be de-selected for you.
C HAPTER 12: ADVANCED ADMINISTRATION 215 3. When View is selected with Merged Windows, the LogViewer displays: Figure 272 Selecting Log Files to View 4. While viewing log files, type CTRL+C to return to the previous screen. 5. If desired, you can change colors in a log file to highl ight what is im portant.
216 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE 7. If desired, you can filter the log file with a regular expression. Type e to add or edit a regular expression and select a log from the list if you have chosen to view several. Figure 275 Adding Expressions in Log Files 8.
C HAPTER 12: ADVANCED ADMINISTRATION 217 9. Select F1 to get help on all LogViewer options. Pressing CTL+C and CTL+Q (as well as a plain q ) terminates this LogViewer session.
218 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE 2. Either click Restart CC-SG Application or press ENTER. Figure 279 Restarting CC-SG in Diagnostic Console Rebooting CC-SG (Admin) This option will reboot the entire CC-SG, which si mulates a power cycle.
C HAPTER 12: ADVANCED ADMINISTRATION 219 2. Either click REBOOT System or press ENTER to reboot CC-SG. A screen to confirm this action appears and needs to be acknowledge d before this operation will commence.
220 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE In Password Configuration , enter the number of passwords that will be remembered. This is the password history, which discourages password reuse and ensures that the new password has not been used within the specified number of previous password changes.
C HAPTER 12: ADVANCED ADMINISTRATION 221 Account Configuration By default, the status acco unt does not require a password, but you can configure it to have one here. Other aspects of the admin password can be configured and the Field Support accounts can be enabled or disabled.
222 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE 4. For the Admin and Status accounts, you can configure: S ETTING D ESCRIPTION User User Name This is the current user name or ID for this account. (This may be operator changeable in a future release.
C HAPTER 12: ADVANCED ADMINISTRATION 223 2. Either click Refresh or press Enter to refresh the display. Refr eshing the display is especially useful when upgrading or installing and you wa nt to see the progress of the RAID disks as they are being rebuilt and being synchronized.
224 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE 2. View the total running, sleeping, total num ber and processes that have stopped. Figure 289 Displaying CC-SG Proc esses in Diagnostic Console 3. Type h to bring up an extensive help screen for the top command.
A PPENDIX A: S PECI FICATIONS 225 Appendix A: Specifications (G1, V1) G1 Platform General Specifications Form Factor 1U Dimensions (DxWxH) 22.1”x 17.32” x 1.75” 563mm x 440mm x 44mm Weight 24.07lb (10.92kg) Power Redundant, hot-swappable power supplies, auto-sensing 110/220 V – 2.
226 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE N ON -O PERATING Temperature 0 - 30 deg C; 32 – 104 deg F Humidity 10% - 90% RH Altitude Operate properly at any altitude between 0 to 10,000 feet, storage 40,000 feet (est.) Vibration 5-55-5 HZ, 0.
A PPENDIX A: S PECI FICATIONS 227 V1 Platform General Specifications Form Factor 1U Dimensions (DxWxH) 24.21”x 19.09” x 1.75” 615mm x 485mm x 44 mm Weight 23.
228 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE N ON -O PERATING Temperature -40 - +60 (-40-140) Humidity 5% - 95% RH Altitude Operate properly at any altitude between 0 to 10,000 feet, storage 40,000 feet (Estim ated) Vibration 5-55-5 HZ, 0.
A PPENDIX B : CC - SG AND NETWORK CONFIGURATION 229 Appendix B: CC-SG and Ne twork Configuration Introduction This appendix discloses network requirements (addresses, protocols and ports) of a typical CommandCenter Secure Gateway (CC-SG) deployment .
230 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Figure 290 CC-SG Deployment Elements Internet (Unsecured Netw ork) CC - SG Cluster Peer CC Clients Internal Network Firewall CC - NOC CC Cli.
A PPENDIX B : CC - SG AND NETWORK CONFIGURATION 231 CC-SG Communication Channels The communication channels are partitioned as follows: • CC-SG ↔ Raritan Devices • CC-SG ↔ CC-SG Clustering (op.
232 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Each CC-SG in the cluster may be on a separ ate LAN. However, the inter-connection between the units should be very reliable and not prone to periods of congestion.
A PPENDIX B : CC - SG AND NETWORK CONFIGURATION 233 The first mode is the primary means for users and administrators to connect to CC-SG. The other two modes are less frequently used.
234 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE CC-SG & SNMP Simple Network Management Protocol (SNMP) allows CC-SG to push SN MP traps (event notifications) to an existing SNMP manager on the network. CC-SG also supports SNMP GET/SET operations with third-party Enterprise Management Solutions, such as HP OpenView.
A PPENDIX B : CC - SG AND NETWORK CONFIGURATION 235 Security and Open Port Scans As part of the CC-SG Quality Assurance process, several open port scanners are applied to the product and Raritan Computer makes certain that its product is not vulnerable to these known attacks.
.
A PPENDIX C: I NITI AL S ETUP P ROCESS O VERVI EW 237 Appendix C: Initial Se tup Process Overview Pre-requisites: • Add Devices with Category/Element clearly identified. • Add Ports with Category/Element clearly identified. Create Group(s)/Add User(s) 1.
238 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE.
A PPENDIX D: U SER G ROUP P RI VIL EGE S 239 Appendix D: User Group Privileges U SERS G ROUP P RIVILEGE A VAILABLE C OMMANDS U SER C APABILITY Application Manager Users are ab le to add new application to CC-SG. Security Manager Users are able to configure security parameters.
240 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE U SERS G ROUP P RIVILEGE A VAILABLE C OMMANDS U SER C APABILITY Configuration Manager Users are able to change general device settings configuration of CC-SG. Add Device Users are able to add new devices.
A PPENDIX D: U SER G ROUP P RI VIL EGE S 241 U SERS G ROUP P RIVILEGE A VAILABLE C OMMANDS U SER C APABILITY Association Manager Users are abl e to associate categories and elements. Device Group Manager Users are able to rename groups and add rules to device groups.
242 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE.
A PPENDIX E: SNMP T RAPS 243 Appendix E: SNMP Traps CC-SG provides the following traps: SNMP T RAP D ESCRIPTION CCDeviceUpgrade CC-SG has upgraded the firmware on a device. CCImageUpgradeResults CC-SG image upgrade results. CCImageUpgradeStarted CC-SG image upgrade started.
244 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE.
A PPENDIX F: T ROUBLESHOOTING 245 Appendix F: Troubleshooting • In order to launch CC-SG from your web brow ser, it requires a Java plug-in. If your machine has an incorrect version, CC-SG will guide you through the installation steps. If your machine does not have a Java plug-in, CC-SG can not automatically launch.
246 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Port and Policy Group Creation Failure The default port groups and policies created in the Association Wizard are named after the elements of a category.
A PPENDIX G: FAQ S 247 Appendix G: FAQs Q UESTION A NSWER General What is CC-SG? CC-SG is a network ma nagement device for aggregating and integrating multiple servers a nd network equipment typically deployed in a datacenter and which are connected to a Raritan IP-enabled product.
248 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Q UESTION A NSWER to add a console/serial port to CC-SG? the following conditions are met: - The Dominion unit is active. - The Dominion unit has not reached the maximum number of configured user accounts.
A PPENDIX G: FAQ S 249 Q UESTION A NSWER If we had more than 1,000 users, how would this be managed? That is, do you support Active Directory? CC-SG works with Microsoft Active Directory, Sun iPlanet or Novell eDirectory.
250 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE Q UESTION A NSWER track down to who switched on or off a power plug? through the CC-SG GUI can be logged to audit logs. Performance As a CC-SG Administrator, I added over 500 ports and assigned all of them to me.
A PPENDIX G: FAQ S 251 Q UESTION A NSWER or simply box level? switches, the tightness of integration will vary. How would I mitigate the restriction of four simultaneous paths through any IP-Reach box, including the roadmap for the potential 8-path box? Currently, the best possible implementation is to aggregate IP- Reach boxes with CC-SG.
252 C OMMAND C ENTER S ECURE G ATEWAY A DMINISTRATOR G UIDE 255-80-5140-00.
A PPENDIX G: FAQ S 253.
North Amer ican Headquarte rs Raritan 400 Cottontail Lane Somerset, NJ 08873 U.S.A. Tel. (732) 764-8886 or (800) 724-8090 Fax (732) 764-8887 Email: sales@raritan.com Website: Raritan.com Raritan NC 4901 Waters Edge Dr. Suite 101 Raleigh, NC 27606 Tel.
Een belangrijk punt na aankoop van elk apparaat Raritan Engineering CC-SG (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Raritan Engineering CC-SG heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Raritan Engineering CC-SG vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Raritan Engineering CC-SG leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Raritan Engineering CC-SG krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Raritan Engineering CC-SG bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Raritan Engineering CC-SG kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Raritan Engineering CC-SG . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.