Gebruiksaanwijzing /service van het product P36-LPG4 van de fabrikant Regency Wraps
Ga naar pagina of 44
Models: P36-NG4 P36-LPG4 Owners & Installation PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE Manual 08/16/07 LISTINGS AND CODE APPROV ALS These gas appliances have been tested in accordance .
Regency ® P36-4 Gas Log Fireplace 2 T O THE NEW OWNER: Congratulations! Y ou are the owner of a state-of-the-art Gas Log Fireplace by FPI FIREPLACE PRODUCTS INTERNA TIONAL. The P36 has been designed to provide you with all the warmth and charm of a wood fi replace at the fl ick of a switch.
Regency ® P36-4 Gas Log Fireplace 3 T ABLE OF CONTENTS OPERA TING INSTRUCTIONS Optional Fan ................................................................ 30 Operating Instructions ................................................. 30 Normal Operating Sounds Of Gas Appliances .
Regency ® P36-4 Gas Log Fireplace 4 DA T A BADGE This is a copy of the label that accompanies each P36 Zero Clearance Room Sealed Gas Fireplace. We have printed a copy of the contents here for your review . (Australia Only) The label is located on the front inside base of the unit, visible when the bottom louvre is open.
Regency ® P36-4 Gas Log Fireplace 5 INST ALLA TION CHECKLIST 1) Locate appliance a) Locate Y our Gas Fireplace b) Clearances c) Combustible Mantels d) Framing & Finishing 2) Assemble T op Standoffs and T op Facing Support and Side Nailing Strips, refer to section "Unit Assembly Prior to Installation".
Regency ® P36-4 Gas Log Fireplace 6 INST ALLA TION Clearances for Bay or Flush Front NOTE: The minimum fl oor clearance must be maintained from the top surface of the carpeting, tile, etc. Minimum Clearance from T op of Unit to: Mantel* Minimum 7" (177mm) Ceiling from top of unit.
Regency ® P36-4 Gas Log Fireplace 7 Because of the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel clearances from top of unit are shown in Diagrams 1 & 2.
Regency ® P36-4 Gas Log Fireplace 8 152m m Si de Wa l l 127m m 51m m Ma n t el l eg Ma n t el l eg P3 6 Fi re p l ace Al l ow abl e m ant el l eg pr oj ect i on. 76m m 38m m INST ALLA TION Note: 40-1/2" (1029mm) is the minimum height for both fl ex termination or Simpson Dura-V ent fl ueing.
Regency ® P36-4 Gas Log Fireplace 9 "C" Screw Position: For a facing material depth of 1-1/4" (32mm), the top facing support must be reversed.
Regency ® P36-4 Gas Log Fireplace 10 INST ALLA TION EXTERIOR FLUE TERMINA TION LOCA TIONS Minimum clearances required for balanced fl ue terminals or the fl ue terminals of outdoor appliances accor.
Regency ® P36-4 Gas Log Fireplace 11 INST ALLA TION FLUEING Regency ® Direct V ent System (Flex) Horizontal T erminations Only These fl ueing systems, in combination with the P36 Room Sealed Gas Fireplace, have been tested and listed as a Direct V ent type fl ue system by the Australian Gas Association.
Regency ® P36-4 Gas Log Fireplace 12 INST ALLA TION Simpson Dura-V ent Co-Axial Flue GS SIMPSON DURA-VENT FLUEING COMPONENTS LIST All Simpson Dura-V ent components are available directly from Regency ® .
Regency ® P36-4 Gas Log Fireplace 13 INST ALLA TION FLUEING ARRANGEMENTS - HORIZONT AL TERMINA TIONS SIMPSON DURA-VENT DIRECT VENT GS SYSTEM and REGENCY ® DIRECT VENT SYSTEM (FLEX) (LPG & NG) The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90 o elbow (two 45 o elbows equal one 90 o elbow).
Regency ® P36-4 Gas Log Fireplace 14 FLUEING ARRANGEMENTS - HORIZONT AL TERMINA TIONS SIMPSON DURA-VENT DIRECT FLUE GS SYSTEM and REGENCY ® CO AXIAL FLUE SYSTEM (FLEX) (LPG & NG) The diagram below shows examples of horizontal termination arrangements using two 90 o elbows (two 45 o elbows equal one 90 o elbow).
Regency ® P36-4 Gas Log Fireplace 15 INST ALLA TION FLUEING ARRANGEMENTS - VERTICAL TERMINA TIONS SIMPSON DURA-VENT CO AXIAL FLUE GS SYSTEM (LPG & NG) The P36 is approved for a 23 ft.
Regency ® P36-4 Gas Log Fireplace 16 The P36 is approved for a 37 ft. (1 1.3m) straight vertical, with Simpson Dura-V ent Co Axial Flue GS fl ue systems for LPG and NG, as per the diagram 3.
Regency ® P36-4 Gas Log Fireplace 17 INST ALLA TION Diagram 5 8) Slide the appliance and fl ue assembly towards the wall carefully inserting the fl ue pipe into the fl ue cap assembly . It is important that the fl ue pipe extends into the fl ue cap suffi cient distance so as to result in a minimum pipe overlap of 1-1/4 inches.
Regency ® P36-4 Gas Log Fireplace 18 Offset Chart Galvanized pipe is desirable above the roofl ine due to its higher corrosion resistance. Continue to add pipe sections through the fl ashing until the height of the fl ue cap meets the minimum height requirements specifi ed in Diagram 5 or local codes.
Regency ® P36-4 Gas Log Fireplace 19 Conversion Kit #513-968 from NG to LPG THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! 1) Shut off the gas supply . 2) Remove the louvers (and bay door if it is installed).
Regency ® P36-4 Gas Log Fireplace 20 GAS PIPE PRESSURE TESTING The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve d uring any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig.
Regency ® P36-4 Gas Log Fireplace 21 OPTIONAL BRICK P ANELS 1) Undo the bottom 2 door latches and open and remove glass door . Remove logs. Note: The logs must not be in the unit. 2) Insert the back brick panel fi rst by carefully slipping it between the back wall of the fi rebox and the rear log bracket.
Regency ® P36-4 Gas Log Fireplace 22 9) Place Log 02-52 between Logs 02-51 and 02-49 and on the indentation on Log 02-54. The bottom right end sits behind the rear grate tab. Log indentation Photo shows rear grate tab. Log 02-51 was removed to show the positioning of Log 02-52.
Regency ® P36-4 Gas Log Fireplace 23 ST ANDARD FLUSH DOOR Diagram 3 Use the hook to pull the spring out until you can put the hook into the slot on the bottom door bracket. Repeat for 2nd spring. See diagram 3. Diagram 2 The standard fl ush door comes with a black frame.
Regency ® P36-4 Gas Log Fireplace 24 1) Unplug the power source. 2) Remove the top louver (if fi tted) by carefully pulling it out. 3) Install the premium fl ush front top louver in place by sliding the louver tabs into the louver brackets on the inside top of the fi rebox.
Regency ® P36-4 Gas Log Fireplace 25 9) Connect the female connecter on the white wire to the TH terminal of the valve. 10) Remove the thermodisc cover from the thermodisc plate by undoing the 2 screws and then remove the wire grommet.
Regency ® P36-4 Gas Log Fireplace 26 18) Install the supplied hinge to the hinge bracket using 2 screws. 20) Secure loose wires using wire clips to the base of the fi rebox as far back as possible. 23) Align the bottom louver mounting tab with hinges on the left and right side and secure using 2 screws on each side.
Regency ® P36-4 Gas Log Fireplace 27 Option 1: W ALL SWITCH 1) Run supplied 15' of wire through the right or left side gas inlet opening. Be careful not to damage wire. Note: We recommend a maximum of 15' of wire but if you wish to go with a longer run, use the Thermostat Wire T able.
Regency ® P36-4 Gas Log Fireplace 28 WIRING CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. This heater does not require a 240V A.C. supply for the gas control to operate.
Regency ® P36-4 Gas Log Fireplace 29 WIRING WITH PREMIUM FLUSH FRONT OPTION INST ALLA TION.
Regency ® P36-4 Gas Log Fireplace 30 OPERA TING INSTRUCTIONS OPERA TING INSTRUCTIONS 1) Read and understand these instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock. 3) Check to ensure there are no gas leaks.
Regency ® P36-4 Gas Log Fireplace 31 OPERA TING INSTRUCTIONS During the fi rst few fi res, a white fi lm may develop on the glass front as part of the curing process. The glass should be cleaned or the fi lm will bake on and become very diffi cult to remove.
Regency ® P36-4 Gas Log Fireplace 32 MAINTENANCE INSTRUCTIONS 1) Always turn off the gas valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year .
Regency ® P36-4 Gas Log Fireplace 33 MAINTENANCE 3) Check for evidences of excessive condensation, such as water droplets forming in the inner liner , and subsequently dripping out the joints, Continuous condensation can cause corrosion of caps, pipe, and fi ttings.
Regency ® P36-4 Gas Log Fireplace 34 10) Undo the pilot tube from the valve with a 7/16" spanner . 11 ) Undo the quick drop out thermocouple nut on the valve with a 9mm (metric) spanner . 12) Remove the Piezo igniter wire and push button assembly .
Regency ® P36-4 Gas Log Fireplace 35 34 BR I CK P AN EL SET 31 30 21 20 14 22 24 28 27 4 3 7 6 8 23 23 30 17 D OOR S & L O U VER S PL EASE 33 35 RE F E R SEP AR A T E SEC T I ON 1 14 2 15 21 37 3.
Regency ® P36-4 Gas Log Fireplace 36 BURNER ASSEMBL Y & LOG SET Part # Description P ARTS LIST 513-560/P V alve Assy - NG 513-562/P V alve Assy - LPG 52) * V alve Tray -NG 53) 430-055 Gasket - V alve Access Plate 54) 910-421 Pilot ON/OFF 3" Extension Knob 55) 910-422 HI/LOW 3" Extension Knob 57) 910-478 S.
Regency ® P36-4 Gas Log Fireplace 37 P ARTS LIST BA Y FRONT ASSEMBL Y Part # Description Part # Description 780-931 Bay Front Complete 103) 940-092/P Side Glass 107) 936-243 Glass Gasket - Soft Fibre.
Regency ® P36-4 Gas Log Fireplace 38 138 132 152 150 148 146 136 135 158 159 160 157 161 139 FLUSH FRONT ACCESSORIES Part # Description P ARTS LIST 132) 512-518 Flush Door Assembly 135) 940-090/P Gla.
Regency ® P36-4 Gas Log Fireplace 39 P ARTS LIST PREMIUM FLUSH FRONT ASSEMBL Y Part # Description 516-916 Premium Flush Front - Black 513-948 Wiring 910-975 Thermodisc 180) * T op Louver 181) * Bottom Louver 182) * Thermodisc Mounting Bracket 183) * Spacers *Not available as a replacement part.
Regency ® P36-4 Gas Log Fireplace 40 513-971 Cast Faceplates (Set) - Black Metallic 201) * Cast Faceplate - Right 202) * Cast Faceplate - T op 203) * Cast Faceplate - Left 513-991 Cast Grills (Set) - Black Metallic (Aust.
Regency ® P36-4 Gas Log Fireplace 41 NOTES ___________________________________________________ ___________________________________________________ ___________________________________________________ .
Regency ® P36-4 Gas Log Fireplace 42 NOTES ___________________________________________________ ___________________________________________________ ___________________________________________________ .
Regency ® P36-4 Gas Log Fireplace 43 W ARRANTY Regency ® Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance T eam care fully inspects each unit thoroughly before it leaves our door .
Printed in Canada © Copyright 2007, FPI Fireplace Products International Ltd. All rights reserved..
Een belangrijk punt na aankoop van elk apparaat Regency Wraps P36-LPG4 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Regency Wraps P36-LPG4 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Regency Wraps P36-LPG4 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Regency Wraps P36-LPG4 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Regency Wraps P36-LPG4 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Regency Wraps P36-LPG4 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Regency Wraps P36-LPG4 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Regency Wraps P36-LPG4 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.