W ARNING: If the information in these instructions are not followed ex- actly , a fi re or explosion may result causing property damage, personal injury or loss of life. FOR YOUR SAFETY Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other appliance.
2 Regency U41-3 UL TIMA TE Gas Fireplace Insert Note: Oversize faceplate 44-1/4" x 31-1/8" Extra Oversize Faceplate 50-1/4" x 35-1/8" TO THE NEW OWNER Congratulations! Y ou are the owner of a state-of-the-art Gas Insert by FIREPLACE PRODUCTS IN- TERNA TIONAL L TD.
3 Regency U41-3 UL TIMA TE Gas Fireplace Insert T ABLE OF CONTENTS REGENCY UL TIMA TE GAS FIREPLACE INSERT SAFETY LABEL Safety Labels ................................................... 4 REQUIREMENTS MA Code - CO Detector (for state of Massachusetts only) .
4 Regency U41-3 UL TIMA TE Gas Fireplace Insert This is a copy of the label that accompanies each Regency UL TIMA TE Gas Insert. We have printed a copy of the contents here for your review . The safety label is located on the right side door panel. NOTE: Regency units are constantly being improved.
5 Regency U41-3 UL TIMA TE Gas Fireplace Insert REQUIREMENTS 5.08: Modifica tions to NFPA-54, Chap ter 10 (2) Revise 10.8. 3 by adding the following a dditional requi rements: (a) For all side wall ho.
6 Regency U41-3 UL TIMA TE Gas Fireplace Insert If the factory built fi replace height is too low for your Insert, you may remove the smoke shelf, baffl e plate, and damper plate from the factory bu.
7 Regency U41-3 UL TIMA TE Gas Fireplace Insert MA TERIALS REQUIRED No electrical power supply is required for the gas control to operate. A 120 V olt AC power cord is hooked up to the fan switch and blower . Plug 3 wire cord into a suitable receptacle.
8 Regency U41-3 UL TIMA TE Gas Fireplace Insert HIGH ELEV A TION This unit is approved in Canada for altitude 2000 ft. to 4500 ft. (CAN/CGA- 2.17-M91) with the orifi ce kit Part # 611-975. For Natural Gas installations above 4500 ft. follow current CAN/CGA-B149.
9 Regency U41-3 UL TIMA TE Gas Fireplace Insert Draft Hood Flue guides screw holes S pill T ube Rear S pill T ube Front INST ALLA TION 1) If the appliance is to be installed into an existing chimney system, thoroughly clean the masonry fi replace and have the chimney swept.
10 Regency U41-3 UL TIMA TE Gas Fireplace Insert INST ALLA TION Before installing vent system ensure that the damper plate is locked into the open position and secure to prevent the damper plate from falling down and crushing the liner .
11 Regency U41-3 UL TIMA TE Gas Fireplace Insert INST ALLA TION T abs Screws Right Side To p Hinged Louvers 3) Using the trim clips provided, join the left side gold trim (the one with the ON/OFF switch and variable speed F AN switch) to the top gold trim.
12 Regency U41-3 UL TIMA TE Gas Fireplace Insert DOOR INST ALLA TION (Packaged Separately) 1) Open the two side doors. 2) Slide the door onto the two hinge pins mak- ing sure the two pieces are fl ush together . See diagram 1. Diagram 1 Diagram 3 Diagram 2 Diagram 4 Diagram 2 Diagram 1 Diagram 3 LOG INST ALLA TION Note: Do not force logs down.
13 Regency U41-3 UL TIMA TE Gas Fireplace Insert INST ALLA TION Thermostat Wire T able OPTIONAL W ALL THERMOST A T A wall thermostat may be installed if desired. Connect the wires as per the wiring diagrams on page 13. Use table on this page to determine the maximum wire length: Note: Preferable if the thermostat is installed on an interior wall.
14 Regency U41-3 UL TIMA TE Gas Fireplace Insert WIRING DIAGRAM This heater does not require a 120V A.C. sup- ply for operation. In case of a power failure, the burner switch and the optional remote control/ thermostat will continue to operate. However , a 120V A.
15 Regency U41-3 UL TIMA TE Gas Fireplace Insert OPERA TING INSTRUCTIONS OPERA TING INSTRUCTIONS Before operating this appliance, proceed through the following check list. 1) Read and understand these Instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock.
16 Regency U41-3 UL TIMA TE Gas Fireplace Insert COPY OF THE LIGHTING PLA TE INSTRUCTIONS OPERA TING INSTRUCTIONS A ) This appliance has a pilot which must be lighted by hand, following the instructions below exactly. B ) BEFORE LIGHTING smell all around the appli- ance area for gas.
17 Regency U41-3 UL TIMA TE Gas Fireplace Insert MAINTENANCE NORMAL OPERA TING SOUNDS OF GAS APPLIANCES It is possible that you will hear some sounds from your gas appliance. This is perfectly normal due to the fact that there are various gauges and types of steel used within your appliance.
18 Regency U41-3 UL TIMA TE Gas Fireplace Insert Installing Glass 1) Install both center and side glass onto extru- sions as per diagram. 2) Place glass assembly into door frame. 3) Install retainers by placing 1 drop of glue where previously glued and put in place.
19 Regency U41-3 UL TIMA TE Gas Fireplace Insert MAINTENANCE CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. F AN MAINTENANCE 1) Unplug or disconnect power source to stove.
20 Regency U41-3 UL TIMA TE Gas Fireplace Insert P ARTS LIST MAIN ASSEMBL Y Part # Description Part # Description 23) 710-028 Faceplate Mounting Bracket 24) 948-241 Door Latch 25) 910-325 Spill Switch.
21 Regency U41-3 UL TIMA TE Gas Fireplace Insert P ARTS LIST BURNER & LOGS Part # Description 52) 910-190 Piezo Ignitor and nut 56) 910-426 Knob - Flame Hi/Low Extension 613-524/P V alve Assembly .
22 Regency U41-3 UL TIMA TE Gas Fireplace Insert F ACEPLA TE & TRIM Part # Description Part # Description 103) * Faceplate - Extra Oversize - Side Left Assy 613-538 Trim Pkg.
23 Regency U41-3 UL TIMA TE Gas Fireplace Insert W ARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance T e am carefully inspects each unit thoroughly before it leaves our facility .
Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Insta.
Een belangrijk punt na aankoop van elk apparaat Regency Wraps U41-LP3 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Regency Wraps U41-LP3 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Regency Wraps U41-LP3 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Regency Wraps U41-LP3 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Regency Wraps U41-LP3 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Regency Wraps U41-LP3 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Regency Wraps U41-LP3 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Regency Wraps U41-LP3 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.