2003.12.19 H8/3802 Group FP-64A User System Interface Cable for E6000 Emulator User’s Manual H8/3802 HS3802ECH61HE Renesas Micr ocomputer Devel opment Environm ent System H8 Family /H8/300L Super Low Pow er Series Rev.
Cautions Keep safety first in your circ uit desi gns! 1. Renesas Technology Corp . puts the maximum e ffort int o making s emiconduct or pr oducts better and more reliable, but the re is always the poss ibility that trouble may occ ur with them. Trouble with semi conducto rs may lead t o personal i njury, fire or propert y damage.
I IMPORTANT INFORMATION READ FIRST • READ this user's manual before using this u ser system interface cable. • KEEP the user's manual handy for future reference. Do not atte mpt to use the user syste m interface ca ble until you fully under stand its mec h an is m.
II LIMITED WARRANTY Renesas warrants its user system interface cabl es to be manufactured in accordance with published specifications and free from defects in material and/or workmanship. Renesas will re pair or replace any user system interfac e cables dete rmined to be defec tive in material and/or workmanship.
III State Law: Some states do not allo w the exclusion or li mitation of implied warranties or liability for incidental o r consequen tial damages, so t he above limitation o r exclus io n may no t ap ply to you. This warr ant y give s yo u spec if ic lega l rig hts, and you ma y have other rig hts wh ic h may va ry fro m state to state.
IV SAFETY PAGE READ FIRST • READ this user's manual before using this u ser system interface cable. • KEEP the user's manual handy for future reference. Do not atte mpt to use the user syste m interface ca ble until you fully under stand its mec h an is m.
V W ARNING Observe the pr ecautions listed below. Failur e to do so will result in a FIRE HA ZARD and will damage the user system and the emula tor product or will result in PERSONAL INJURY. Th e USER PROGRAM will be LOST. 1. Do not repair or remodel the emulator product b y yourself for e lectric sho ck prevention and quality assurance.
i Preface Thank y ou for purchasi ng th is user s ys tem interface cable (HS3802EC H61H) for the R enesas’ s origin al microcom puter H8/3802, H8/38004 g roup.
ii Contents Section 1 Configuration .................................................................................... 1 Section 2 Connection Procedures ...................................................................... 3 2.1 Connectin g User System Interface Cable to Em ulator Station .
1 Section 1 Configuration CAUTION Use an IC149-064- 008-B5 socket ( manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the FP-64A package IC socket on th e user system. Figu re 1 show s the config uration of the HS3802ECH61H u ser system interface cable for th e FP-64A pack age.
2 Table 1 lists t he HS3802ECH61H com ponents . Please make sure y ou have all of th ese compon ents when u npacking. Table 1 HS3802ECH61H Com ponents No.
3 Section 2 Connection Procedures 2.1 Connectin g User System Interface Cable to E mulator Station W ARNING Observe the precautions listed below. Failure t o do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY.
4 Emulator station Cable body connector User system interface cable E6000 Figure 2 Connecting User System Interface Cable to Em ulator Station.
5 2.2 Connectin g User System Interface Cable to User S ystem W ARNING Always switch OFF the user syst em and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part . Before connecting, make sure that pin 1 on bot h sides are correctly aligned.
6 2.2.3 I nserting Cable Head CAUTION Check the location of pin 1 before inserting. Align pin 1 on the IC socket for an FP-64A packag e on the user sy stem w ith pin 1 on th e user system interface cable head, and in sert the user system interface cable head into th e IC socket on the user sy stem, as show n in figure 3.
7 Fasten the us er system interf ace cable head to the IC socket for an FP-64A packag e on the user system with the four screws (M2 x 12 mm ; with four flat w ashers) provided. Each s crew should be tighten ed a little at a time, altern ating between screw s on opposing corners.
8 2.2.5 Fastening Cable B ody Connect the cable body t o the cable head. Cable body Cable head Remove jig Push the remove jigs. Removing User system Figure 4 Fastening Cable Body.
9 2.3 Recomm ended Dime nsions for User System Mount Pad Figure 5 show s the recomm ended dimens ions for the mou nt pad (footprin t) for the user system w ith an IC socket for an FP-64A package (IC 149-064-008- B5: manu factured by YAMAICHI ELECTRONICS C o.
10 2.4 Dimensions f or User System Interface Cabl e Head The dimens ions for the user sy stem interface cable h ead are shown in f igure 6. Unit: mm Tolerance: ±0.
11 2.5 Resulting Di mensions after Con necting User S ystem Interface Cable The resulting dim ensions, after connectin g the user system interface cable head to the u ser system , are show n in figure 7. IC socket (IC149-064-008-B5 manufactured by YAMAICHI ELECTRONICS Co.
12 Section 3 Installing the MCU to the User System CAUTION 1. Check the locat ion of pin 1 before inserting. 2. Use a Philips-type screwdriver whose head matches the screw head.
13 MCU Pin 1 IC socket (IC149-064-008-B5 manufactured by YAMAICHI ELECTRONICS Co., Ltd.) User system Screws (M2 x 8 mm) with flat washers Socket cover Figure 8 Installing M CU to User System.
14 Section 4 Verifying Operation 1. When u sing the H8/ 3802 group E6000 em ulator (HS3800EPI60H), tu rn on the em ulator according to th e procedures described in the H8/3802 Group E6000 Emu lator User's Manual (HS3800EPI60HE).
15 Figure 9 sho ws th e system clock oscillator o n the user system interface cable an d the subclock input specificat ions. R2 270 R1 1 M HCU04 HCU04 To E6000 emulator OSC1 OSC2 System clock oscillator Ω Ω 4.0 V 19 ns max. 19 ns max. 4.0 V 1.35 V 0 V 5.
16 Section 5 Notice 1. Make sure that pin 1 on the user system IC socket is correctly aligned w ith pin 1 on the cable head before insertin g the cable head into the us er system IC sock et. 2. The dimens ions of th e recommen ded moun t pad for the user sy stem IC socket are diff erent from those of th e MCU.
17 P1 31 Figure 11 P1 Short Connector.
H8/3802 Group FP-64A User System Interface Cable for E6000 Emulator User's Manual Publication Date: Rev.3.00, December 19, 2003 Published by: Sales Strategic Planning Div. Renesas Technology Corp. Edited by: Technical Documentation & Information Department Renesas Kodaira Semiconductor Co.
H8/3 802 Grou p FP-64 A User Sy stem I nterface Cable for E600 0 Emulato r User’s Ma nual REJ10B0098-0300H.
Een belangrijk punt na aankoop van elk apparaat Renesas H8/3802 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Renesas H8/3802 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Renesas H8/3802 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Renesas H8/3802 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Renesas H8/3802 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Renesas H8/3802 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Renesas H8/3802 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Renesas H8/3802 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.