RIDGID SP-330 Sump Pump

28 pagina's·2.9 MB·Waterpomp·PDF·EN
RIDGID SP-330 Sump Pump
Inhoudsopgave 38 secties SP-330 SP-330D SP-500 SP-500A · Submersible Sump Pumps · OPERATOR’S MANUAL · Table of Contents · … TonenVerbergen
Page 1 of the RIDGID SP-330 Sump Pump user manual — OPERATOR’S MANUAL
Pagina 1 · klik om te vergroten
Pagina 1

SP-330 SP-330D SP-500 SP-500A

Submersible Sump Pumps

RIDGID SP-330 Sump Pump — SP-330 SP-330D SP-500 SP-500A diagram (page 1)
Afb. 1
RIDGID SP-330 Sump Pump — SP-330 SP-330D SP-500 SP-500A diagram (page 1)
Afb. 2

OPERATOR’S MANUAL

  • Pour français voire page 9
  • Para ver el castellano vea la paginá 17
RIDGID SP-330 Sump Pump — OPERATOR’S MANUAL diagram (page 1)
Afb. 3
RIDGID SP-330 Sump Pump — OPERATOR’S MANUAL diagram (page 1)
Afb. 4

Read this Operator’s Manual carefully before using this tool. Failure to understand and follow the contents of this manual may result in electrical shock, fire and/or serious personal injury.

Page 3 of the RIDGID SP-330 Sump Pump user manual — SP-330, SP-330D, and SP-500, SP-500A Submersible Sump Pumps
Pagina 3 · klik om te vergroten
Pagina 3
RIDGID SP-330 Sump Pump — SP-330, SP-330D, and SP-500, SP-500A Submersible Sump Pumps diagram (page 3)
Afb. 5 · SP-330, SP-330D, and SP-500, SP-500A Submersible Sum…
RIDGID SP-330 Sump Pump — SP-330, SP-330D, and SP-500, SP-500A Submersible Sump Pumps diagram (page 3)
Afb. 6 · SP-330, SP-330D, and SP-500, SP-500A Submersible Sum…
RIDGID SP-330 Sump Pump — SP-330, SP-330D, and SP-500, SP-500A Submersible Sump Pumps diagram (page 3)
Afb. 7 · SP-330, SP-330D, and SP-500, SP-500A Submersible Sum…
RIDGID SP-330 Sump Pump — SP-330, SP-330D, and SP-500, SP-500A Submersible Sump Pumps diagram (page 3)
Afb. 8 · SP-330, SP-330D, and SP-500, SP-500A Submersible Sum…

SP-330, SP-330D, and SP-500, SP-500A Submersible Sump Pumps

Record Serial Number From Product Decal Below

Serial No.

351403-005 4/04

Page 4 of the RIDGID SP-330 Sump Pump user manual — Electrical Safety
Pagina 4 · klik om te vergroten
Pagina 4

General Safety Information Safety is a combination of common sense, staying alert and understanding how your sump pump works.

  • Do not abuse cord. Never use the cord to carry the pump or pull the plug from an outlet. Keep cord away from heat, oil, sharp edges, or moving parts. Replace damaged cords immediately. Damaged cords increase the risk of electrical shock.

Safety Signal Words

! DANGER

means if the safety information is not followed someone will be seriously injured or killed.

  • Pump must be plugged into an outlet receptacle that includes a Ground Fault Circuit Interrupter (GFCI). In the event of current leakage, a GFCI will trip, thus reducing the risk of serious injury or death from electrical shock.

means if safety information is not fol- lowed someone could be seriously injured or killed.

! CAUTION

means if safety information is not fol- lowed someone may be injured.

NOTICE

indicates important information, that if not followed, may cause damage to the equipment or flooding.

TEST RESET

Read and understand all instruc- tions. Failure to follow all instructions listed below may result in fatal electric shock, fire, property damage, and/or serious personal injury.

  • Before using, test the Ground Fault Circuit Interrupter (GFCI) to insure it is operating correctly . A GFCI reduces the risk of electrical shock.

SAVE THESE INSTRUCTIONS!

Work Area

  • Do not use an extension cord. This increases the risk of electrical shock. If necessary, install a properly grounded outlet closer to the pump.

! DANGER

  • Do not operate pump in explosive atmospheres, such as in the presence of flammable liquids, gases, or dust. Pump motors create sparks which may ignite the dust or fumes.
  • Keep by-standers, children, and visitors away while installing pump. Distractions can result in mistakes.

Personal Safety

  • Stay alert, watch what you are doing, and use common sense when installing this pump. Do not attempt to install this pump while tired or under the influence of drugs, alcohol or medications. A moment of inattention may result in serious personal injury.

Electrical Safety

  • This pump must be plugged into an outlet, properly installed, and grounded in accordance with all applicable codes and ordinances. Never remove the grounding prong or modify the plug in any way. Do not use any adapter plugs. Check with a qualified electrician if you are not sure the outlet is grounded. If the pump should electrically malfunction or break down, grounding provides a low resistance path to carry electricity away from the user.
  • Dress properly. Do not wear loose clothing or jewelry. Contain long hair. Keep your hair, clothing, and gloves away from moving parts. Loose clothes, jewelry, or long hair can be caught in moving parts.
  • Do not overreach. Keep proper footing and balance at all times. Proper footing and balance enables better control in unexpected situations.
  • Electrical wiring must be performed by a qualified electrician. Improper wiring could result in fatal electrical shock.
  • Use safety equipment. Always wear eye protection. Dust mask, non-skid safety shoes and hard hat must be used for appropriate conditions.
Show 6 more labels / short text on this page
Grounded · Grounding · Outlet · Blade · Power · Cord
Page 5 of the RIDGID SP-330 Sump Pump user manual — NOTICE
Pagina 5 · klik om te vergroten
Pagina 5

Service

ground near the pump, do not walk on wet area until all power is turned off. If the shut-off box is in the basement, call an electrician. Failure to follow this warning could result in fatal electrical shock.

  • The motor is oil filled and sealed for cooler running. Allow 2 hours for the motor to cool before servicing. Hot oil is under pressure and could result in severe burns.
  • Always disconnect the power source before attempting to install, service, relocate, or maintain the pump. Never handle a pump or pump motor with wet hands or when standing on wet or damp surface or in water. Failure to follow this warning could result in personal injury and/or death.
  • Pump service must be performed only by qualified repair personnel. Service or maintenance performed by unqualified repair personnel could result in injury and may void the warranty.
  • When servicing a pump, use only identical replacement parts. Follow instructions in the Maintenance Section of this manual. Use of unauthorized parts or failure to follow maintenance instructions may create a risk of electrical shock or injury.
  • Pump motor is equipped with automatic resetting thermal protector that could restart unexpectedly. Disconnect power source when servicing pump.
  • Do not modify float or position float switch so that pump will operate continuously. Pump is not designed for continuous operation, this will reduce performance and life of the pump.

Specific Safety Information

  • Do not hang pump by handle for permanent installation. This minimizes twisting which can lead to damage during pump operations.

Risk of electric shock. This pump is supplied with a grounding-type plug. To reduce risk of electric shock be certain that it is connect- ed only to a properly grounded, grounding-type receptacle that is protected by a GFCI.

Description and Specifications

Description The submersible pump is designed for home sump operations only. The unit is equipped with an 8 foot, 3- prong grounding type power cord. The motor has an automatic reset thermal protector to prevent burnouts due to overloading or clogging. A float activated switch provides automatic operation to maintain water level between factory preset points.

For your own safety, before assembling and operating this unit, read this operators manual carefully and com- pletely. Learn the operation, application, and potential hazards peculiar to this unit.

Call the Ridge Tool Company, Technical Services Department at (800) 519-3456 if you have any ques- tions.

NOTICE

This pump is not designed to handle salt water, brine, laundry discharge, or any other appli- cation which may contain caustic chemicals and/or for- eign materials. This pump is not suitable for use with aquatic life. Pump damage or failure could occur if used in these applications and will void the warranty.

Submersible Pump Safety

! DANGER

  • Do not use to pump flammable or explosive fluids such as gasoline, fuel oil, kerosene, solvents, thinners etc. Do not use in a flammable and/or explosive atmosphere. Pump should only be used to pump clear water. Improper use could result in personal injury and/or death.

NOTICE

It is strongly recommended that a battery back-up system be used. Power outages, excessive water flow, G.F.C.I. tripping and primary pump wear can cause flooding. A battery back-up sys- tem reduces this risk. Contact your Ridge Tool distrib- utor.

  • If there is water or moisture on the floor or
Page 6 of the RIDGID SP-330 Sump Pump user manual — Figure 2 – Submersible Pump Installation
Pagina 6 · klik om te vergroten
Pagina 6

Specifications

  • Pump must be plugged into an outlet receptacle that includes a Ground Fault Circuit Interrupter (GFCI) (Figure 1).

Motor:

Type Shaded Pole Rating 120V, Single Phase

  • Always disconnect the power source before attempting to install, service, relocate, or maintain the pump. Never handle a pump or pump motor with wet hands or when standing on wet or damp surface or in water.

1/3 HP, 9.5 Amps 1/2 HP, 10 Amps Pump

1/3 HP 3100 GPH @ 0 Ft. 1/2 HP 4400 GPH @ 0 Ft. Liquid temperature range 40F to 120F Cut in level 9” Cut out level 4”

Installation

1. Construct a sump pit from concrete, steel, or plastic that is 24” deep and at least 11” in diameter (Figure 2 next page). If the sump already exists, make sure it is the proper size.

Performance Curve

2. Make sure the electrical outlet is grounded and is rated for 115 volts and at least 15 amps. The outlet must be protected by a Ground Fault Circuit Interrupter (GFCI).

SP-300 SP-300D SP-500 SP-500A

Use of a grounded receptacle that is protected by a GFCI reduces risk of a fatal electrical shock.

3. Inspect the power cord and plug for damage. If the plug is missing the grounding prong or the cord is damaged, do not install the pump until the cord has been replaced.

1000 2000 3000 4000 5000 6000

Performance Chart

(Model SP-330D Diaphragm Switch only) 4. Remove the two fasteners in the cast iron volute near the discharge area. Align the hole with the diaphragm switch and replace the fasteners with- out over tightening.

Model Discharge Head 0’ 5’ 10’ 15’

SP-330 Gallons/Hour 3100 3000 2700 1680

SP-330D Gallons/Hour 3100 3000 2700 1680

SP-500 Gallons/Hour 4400 4100 3200 2000

SP-500A Gallons/Hour 4400 4100 3200 2000

Pump Installation

! DANGER

  • Pump should only be used to pump clear water. Do not use to pump fluids such as gasoline, fuel oil, or kerosene. Do not use in a flammable or explosive atmosphere. Improper use could result in personal injury and/or death.

To prevent property damage, serious injury, or death, proper installation of the pump is required. The following procedures should be followed:

Figure 2 – Submersible Pump Installation

Discharge (Feet) · Gallons Per Hour

Page 7 of the RIDGID SP-330 Sump Pump user manual — NOTICE
Pagina 7 · klik om te vergroten
Pagina 7

! WARNING 9. Insert the pump cord plug directly into 115 volt grounded electrical outlet that is protected by Ground Fault Circuit Interrupter (GFCI) (Figure 1).

RIDGID SP-330 Sump Pump — Specifications diagram (page 7)
Afb. 9 · Specifications

Never cut off grounding prong or use an adapter.

Support pump and piping when assembling and after installation. Failure to do so could cause piping to break or pump to fail, which could result in property damage and/or personal injury.

When routing electrical cord protect cord from sharp objects, hot surfaces, oils, and chemi- cals. Do not kink cord, replace any damaged cord immediately.

5. Set pump into sump. Locate the pump on a solid level surface.

NOTICE

Do not place directly on clay, gravel, or any loose or sandy surfaces. These surfaces con- tain small stones or sand that may clog or damage the pump, which could result in pump failure causing flooding and property damage.

6. This pump has a 1-1/2” NPT discharge. If existing piping is 1-1/4” NPT, an adapter bushing (not included) may be used. Do not use piping that is less than 1-1/4” NPT. Piping that is too small will result in reduced output.
7. A check valve is required in the discharge line to prevent backflow when the pump shuts off. It is best to install the check-valve directly to the pump discharge. Thread a check valve into pump discharge.

NOTICE

Be careful not to strip or cross- thread. Do not use pipe joint sealant.

NOTICE

Flexible discharge hose is intended for temporary use only. Rigid PVC or metal pipe is required for a permanent installation. If flexible dis- charge hose is temporarily used, make sure pump is secured in sump pit to prevent movement. Failure to secure pump could allow pump movement and cause switch interference and prevent pump from starting or stopping. This could result in flooding and property damage.

Unit should be plugged into outlet as shown in figure 4. Do not plug alarm box in upside down. Doing so may cause the pump to unplug. If the outlet is upside down, have a qualified electrician reposition the outlet before installing the unit.

8. Connect 1-1/4” diameter rigid pipe to rubber boot on check valve (not included). Reverse boot for 11/2” diameter pipe. Tighten clamps.
2. While the pump is draining the pit, verify that the discharge piping is carrying the water to a point at least 15 feet away from the foundation.
Page 8 of the RIDGID SP-330 Sump Pump user manual — Maintenance Instructions
Pagina 8 · klik om te vergroten
Pagina 8

The outside piping must be tilted downward to drain. This helps prevent debris from entering the discharge pipe, and also prevents trapped water from freezing which can damage the pump.

Suggested Part Replacement Schedule

Replace pump switch every 2 years. See page 7 for Ridgid cat. #.

3. Install sump pit cover (not included) to prevent debris from clogging or damaging the pump.

Replace float every 2 years. See page 7 for Ridgid cat. #.

Flood Alarm Models Testing Alarm-(see figure 4)

Service And Repair

Press and hold test button until alarm sounds. If alarm does not activate after 3 seconds check and/or replace battery then repeat test.

  • Service and repair work on this pump must be performed by qualified repair personnel. Pump should be taken to a RIDGID Independent Authorized Service Center or returned to the factory. All repairs made by Ridge service facilities are warranted against defects in material and workmanship.

Testing water level sensor–(see figure 3)

Alarm activates when water level raises the small white float. Test water level sensor operation by lifting it until alarm activates. A 3 to 5 second delay is normal.

  • When servicing this pump, only identical replacement parts should be used. Failure to follow these steps may create a risk of flooding, property damage, fatal electrical shock, or other serious injury and may also void your warranty.

Maintenance Instructions

  • Always disconnect the electrical supply or unplug the pump before attempting to install, service, relocate, or perform any maintenance. If the power source is out of sight, lock and tag in the open (OFF) position to prevent unexpected power application. Failure to do so could result in fatal electrical shock. Only a qualified technician should repair this unit. Improper repair could result in fatal electrical shock.

If you have any questions regarding the service or repair of this machine, call or write to:

Ridge Tool Company Technical Service Department 400 Clark Street Elyria, Ohio 44036-2023 Tel: (800) 519-3456 E-Mail: TechService@ridgid.com

  • The motor is oil filled and sealed for cooler running. Allow 2 hours for motor to cool before servicing. Hot oil under pressure could result in severe burns.

For name and address of your nearest Independent Authorized Service Center, contact the Ridge Tool Company at (800) 519-3456 or http://www.ridgid.com

1. Check the operation of the Ground Fault Circuit Interrupter (GFCI) on a monthly basis.
2. Keep pump inlet clean and free of all foreign objects. Inspect at least once a year and clean sump as needed.
3. Check pump for proper operation monthly by filling sump with water until pump turns on.
4. Inspect all plumbing connections for any leaks or looseness monthly.
Page 9 of the RIDGID SP-330 Sump Pump user manual — Suggested Part Replacement Schedule
Pagina 9 · klik om te vergroten
Pagina 9
Troubleshooting ! WARNING Let the pump cool for a minimum of two hours before servicing because the pump contains hot oil under pressure. Disconnect pump from power source before servicing. TROUBLESHOOTING CHART SymptomPossible Cause(s)Corrective Action Pump will not start or run1. Blown fuse or breaker 2. Low line voltage 3. Worn motor 4. Worn switch 5. Impeller not rotating 6. Float obstruction1. If blown, replace with proper sized fuse or reset breaker. 2. If voltage is under 108 volts, check wiring size. 3. Replace motor or pump. 4. Replace switch. 5. If impeller will not turn, remove housing and remove blockage. 6. Make sure float moves freely up and down. Pumps start and stops too often1. Backflow of water from piping 2. Defective switch1. Install or replace check valve. 2. Replace switch. Pump will not shut off or thermal protector turns off1. Defective switch 2. Obstacle in piping 3. Float obstructed1. Replace switch. 2. Remove pump and clean pump and piping. 3. Make sure float moves freely up and down. Pump operates but delivers little or no water1. Low line voltage 2. Plugged impeller1. If voltage is under 108 volts, check wiring size. 2. Clean out impeller.
FigureDescriptionRIDGID cat. SP330# RIDGID cat. # SP330D RIDGID cat. # SP500RIDGID cat. # SP500A 1 2 2a 2b 3 4 5 6Float Kit Switch/Top Assembly Top Assembly/diaphragm Alarm top assembly/switch Stator Lower Bracket/Rotor Cast Iron Impeller Cast Iron Volute88557 88562 N/A N/A 88577 88587 88597 88602N/A N/A 88567 N/A 88577 88587 88597 9038288557 88562 N/A N/A 88582 88592 88597 8860288557 N/A N/A 88572 88582 88592 88597 88602

2b 2a

Page 10 of the RIDGID SP-330 Sump Pump user manual — Suggested Part Replacement Schedule
Pagina 10 · klik om te vergroten
Pagina 10
Page 10 of the RIDGID SP-330 Sump Pump user manual — Suggested Part Replacement Schedule
Page 11 of the RIDGID SP-330 Sump Pump user manual — Pompes de puisard submersibles SP-330, SP-330D et SP-500, SP-500A
Pagina 11 · klik om te vergroten
Pagina 11

Pompes de puisard submersibles SP-330, SP-330D, SP-500, & SP-500A

Pompes de puisard submersibles SP-330, SP-330D et SP-500, SP-500A

Enregistrez le numéro de série de la décalcomanie du produit ci-après

No. de série

351403-005 4/04

Probleemoplossing

Probleemoplossing

Veelvoorkomende problemen, mogelijke oorzaken en oplossingen.

ProbleemMogelijke oorzaakOplossing
Symptom p.9
Pump will not start or run p.9
Pumps start and stops too often p.9
Pump will not shut off or thermal protector turns off p.9
Pump operates but delivers little or no water p.9

Vraag stellen over de RIDGID SP-330 Sump Pump

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.