SECTION 6: H EATER I NSTALLAT ION 15 F IGURE 1 5: Linear Heat er A ssembly O vervie w T ube Ref lector Ref lector End C ap Ref lector Support Burner Coupling U-Clips Burner T ube T ube and Ref lector .
BH-S ERIES I NSTA LLATION , O PERAT ION AN D S ER VICE M ANUAL 16 F IGURE 1 6: Linear Heat er L ay out Ov erview a = 1 4" (36 cm) ref lector width (not sho wn) b = 2" (5 cm) end cap to b urner c = 2" (5 cm) end cap to hanger d= 7 ' 6" (2.
SECTION 6: H EATER I NSTALLAT ION 17 F IGURE 1 7: Linear Heat er Lay out Ov er vie w (Continued) Step 6.1 Bur ner T ube Installat ion g c b de f e e e e g c b de f e e e e e g c b de f e e e e e e 60 ' (1 8.3 m) T ube Length 70 ' (21 . 3 m) T ube Length 80 ' (24.
BH-S ERIES I NSTA LLATION , O PERAT ION AN D S ER VICE M ANUAL 18 Step 6.2 T ube Clamp P acka g e I nstallation Step 6.3 Coupl in g and T ube Assembly Bolt T ube Clamp Flat W asher Nut (T orque 1 20 in/lb 1 3.
SECTION 6: H EATER I NSTALLAT ION 19 Step 6.3. 1 Couplin g and T ube A ssembly (Conti nued) Step 6.3. 2 Couplin g and T ube A ssembly (Conti nued) Incorr ect slide bar position Corr ect slide bar dimensions ± 2" (5 cm) Drive slide bar until tight.
BH-S ERIES I NSTA LLATION , O PERAT ION AN D S ER VICE M ANUAL 20 Step 6.4 T urb ulator Instal lation T w i s t P ull String Ta b Fold t ab around outside of tube nearest t o the vent t o hold turbulat or in place. T urbulator Section T urbulator Adapt er Description Part Number T urbulator A dapter 2.
SECTION 6: H EATER I NSTALLAT ION 21 Step 6.5 R eflect or Installat ion W ARNING F ire Hazar d Support ref lector with r ef lector hanger and support strap. Ref lector m ust not touch t ube . Failur e to follo w these instructions can r esult in death, injur y or property damage .
BH-S ERIES I NSTA LLATION , O PERAT ION AN D S ER VICE M ANUAL 22 Step 6.5. 1 Ref lect or , U-Clip and R ef lector Support Instal lation The pict orial dra w ings of the heat er construction in Section 6 ar e schematic only and pro vide a general guideline of wher e hanger s, r eflect or suppor ts and U-clips are t o be instal led.
SECTION 6: H EATER I NSTALLAT ION 23 Step 6.6 Bur ner Installat ion Lock W asher Gasket Burner Bolt (T orque 1 20 in/lb 1 3.56 Nm) S-h ook Burner T ube Extra chain min.
BH-S ERIES I NSTA LLATION , O PERAT ION AN D S ER VICE M ANUAL 24 SECTION 7: OPTIONAL HEATER ACCESSORI ES 7 .1 U-T ube Confi g uration Heat ers (e x cept BH-40) ar e appro v ed f or optional U-tube conf igurati ons.
SECTION 7 : O PTIONAL H EATER A CCESSORIES 25 FI G U R E 1 8 : U-T ube Heater A ssembly Ov ervie w U-tube 1 8" (46 cm) Cent er to C enter U-clips Ref lector End Caps 12 Burner Ref lector T urbula.
BH-S ERIES I NSTA LLATION , O PERAT ION AN D S ER VICE M ANUAL 26 F IGURE 1 9: U-T ube Heater L a yout O verview LEGEND a = 1 4" (36 cm) Ref lector Width (Not Sho wn) b = 2" (5 cm) End Cap t o Burner c = 2" (5 cm) End Cap t o Hanger d= 7 ' 6" (2.
SECTION 7 : O PTIONAL H EATER A CCESSORIES 27 F IGURE 20: U-T ube Lay out O ve rview (Conti nued) 7 .2 Elbow P acka g e Conf i g ura tion Step 7 .2.1 Elbo w Installation g c b de h e f g c b de h e e g c b de h e 60 ' (1 8.3 m) T ube Length 70 ' (21 .
BH-S ERIES I NSTA LLATION , O PERAT ION AN D S ER VICE M ANUAL 28 Step 7 .2.2 Elbo w Installation Step 7 .2.3 Ref lect or Joint Inst allation Step 7 .2.4 Ref lect or Joint Inst allation T ube C o up l in g Reflector Reflector J oint Flatten Edge 1" (2.
SECTION 7 : O PTIONAL H EATER A CCESSORIES 29 Step 7 .2.5 Ref lect or Joint Detail F IGUR E 21: Ref lector J oint Detail I nstall reflector end cap . Attac h reflector j oint wit h si x #8 s h eet m etal screws .
BH-S ERIES I NSTA LLATION , O PERAT ION AN D S ER VICE M ANUAL 30 7 .3 Ref lector Side Ext ension Step 7 .3.1 Br ack et Insta llation Step 7 .3.2 Sid e Ref lector Installation Ref lector Side Extension Brac ket (2 per Ref lector) Use additional suppor ts in high air mov ement applications.
SECTION 7 : O PTIONAL H EATER A CCESSORIES 31 7 .4 Low er Clear ance Shield Install ation Step 7 .4.1 Shield Support Strap Assemb ly 7 .5 T wo- Foo t Decorati ve Grille Instal lation Step 7 .
BH-S ERIES I NSTA LLATION , O PERAT ION AN D S ER VICE M ANUAL 32 Step 7 .5.2 F r ame Shield Installat ion Step 7 .5.3 Ref lect or Side Ext ension Installation f or Decorati ve Gr illes Sh ield Descri.
SECTION 7 : O PTIONAL H EATER A CCESSORIES 33 7 .6 Pr otectiv e Gr ille Installat ion Step 7 .6.1 Sili cone Cap Installa tion Step 7 .6.2 Gr ille End Cap Installati on Step 7 .6.3 Grille Ins tallation Silicone Cap Grille Finger Description Part Number Grille Section 0805000 1 Grille End Cap 08050002 Silicone C ap 9191 5951 -6P Bend up 90° .
BH-S ERIES I NSTA LLATION , O PERAT ION AN D S ER VICE M ANUAL 34 SECTION 8 : V ENTING 8 .1 V entin g This heat er must be v ent ed in accordance w ith the rules contained in thi s manual and wit h th.
SECTION 8 : V ENTING 35 8 .2 Un vent ed Oper ation Suf fi cien t v ent ilat ion m ust be pr ovide d in t he am ount of 4 cfm pe r 1 000 Btu/h fir ing rate (Unit ed States); 3 cfm per 1 000 Btu/h firing rate (Canada). Use of optional out side combus tion air is not re commended with un v ent ed heater s.
BH-S ERIES I NSTA LLATION , O PERAT ION AN D S ER VICE M ANUAL 36 8 .7 Horiz ontal V entilation 4'' (1 0 cm) Pipe 8 . 8 V er tical V entilation 4'' ( 1 0 cm) Pipe 4" (1 0 cm) Single W all Pipe V ent Adapt er V ent T er minal Combustib le or Non-Combustib le Wall V ent Adapt er 1 8" (46 cm) Min.
SECTION 8 : V ENTING 37 8 .9 Common Side W all V entin g R equirements: • Maximu m of t wo heate rs c an be commonly v ent ed thr ough a side w all. • Heat er s must be of t he same BTU output. • Heater s must be controll ed by a common thermostat.
BH-S ERIES I NSTA LLATION , O PERAT ION AN D S ER VICE M ANUAL 38 8 .1 0 Common V er tical V entin g R equirements: • Maximum of f our heater s can be commonly v ented t hrough the r oof . • Heat er s must b e of the same BTU output. • Heat er s must b e contr olled by a common thermostat.
SECTION 8 : V ENTING 39 8 .1 1 Outside Comb ustion A ir Supply IMPOR T ANT: If the b uilding has a slight neg ativ e pr essur e or corr osive cont aminants , such as halogenat ed h y drocarbons , are pre sent in the air , an outside comb ustion air supply t o the heat er is r equir ed.
BH-S ERIES I NSTA LLATION , O PERAT ION AN D S ER VICE M ANUAL 40 8 .1 1 .4 V ertical Outside A ir Supply f or Double Heat er Installation R equirements: • Heat er s must b e contr olled by a common thermostat.
SECTION 9: G AS P IPING 41 SECTION 9: GAS PIPING Instal l the g as hose as sho wn in F igure 23 . The ga s hose accommodat es e xpansion of the heati ng sy stem and allo ws f or eas y insta llation and service of the b urner .
BH-S ERIES I NSTA LLATION , O PERAT ION AN D S ER VICE M ANUAL 42 F IGURE 23: Gas Connection w ith Flexi ble Gas Hose 90° Pipe El b o w ( N ot Incl u ded) Sh u t-Of f V al v e (incl u ded w ith gas hose) m u st b e parallel t o bu rner gas inlet. The 3" ( 8 cm) displacement sho w n is f or the cold condition.
SECTION 10: W IRING 43 SECTION 1 0: WIR ING Heat ers can be controlle d using se v eral methods . Normally ther mostats ar e used to cont rol the heater s b ut they can al so be contro lled b y an energy management s yst em. Section 1 0.1 illustra t es the connectio n f or heat er s contr olled b y a line v oltage thermostat.
BH-S ERIES I NSTA LLATION , O PERAT ION AN D S ER VICE M ANUAL 44 10 . 2 L o w V o l t a g e Thermostat Wir in g R C W G Y 1 2 3 4 5 6 COIL L1 L2 Gnd. N H Gnd.
SECTION 10: W IRING 45 1 0.3 Internal Wirin g Pr e ssur e Swi t ch B L UE B L UE B L UE 2 4 V A / C B L ACK F l a m e S ense YE LL O WG ro und BRO W N M ain V a l ve El e c t ro de B L ACK B L ACK B L.
BH-S ERIES I NSTA LLATION , O PERAT ION AN D S ER VICE M ANUAL 46 1 0 .4 L add er Di a g ram 1 0.5 Electr i cal Conne ction t o the Bur ner Pow e r V al ve S en s e Grou nd Spark T ra n sf or m e r Bl.
SECTION 1 1: O PERATIO N AND M AINT ENANCE 47 SECTION 1 1: OPERATION AND MAINTENANCE This heat er is equipped w ith a direc t spark ignition syste m. 11 . 1 S e q uence of Operation 1 . T ur n the thermostat up . Wh en the therm ostat calls f or heat, the blo wer mot or w ill ener gize.
BH-S ERIES I NSTA LLATION , O PERAT ION AN D S ER VICE M ANUAL 48 F or best per formance, the g as, el ectrical, thermostat connections , tubing , venting , suspensio ns and ov erall heat er condition shoul d be inspected thor oughly . NO TE: G as fl ow and b ur ner ignition ar e among the fi rst t hings tha t should be i nspected.
SECTION 1 1: O PERATIO N AND M AINT ENANCE 49 1 1 .5 Maintenance Chec klist Install ation Code and Ann ual Inspect ions: All inst allation and service of ROBER TS GORDON ® equipment m ust be per f or.
BH-S ERIES I NSTA LLATION , O PERAT ION AN D S ER VICE M ANUAL 50 Burner Cup and Ori f ice Clear of obstructions (e ven spi der webs w ill cause pr obl ems). C areful ly remo ve any dust and debris fr om the burner . Electr ode Replac e if there ar e cr ack ed ceramics , e x cessi ve carbon r esidue, or er osion of the electr ode .
SECTION 12 : T ROUBLE SHO OTING 51 SECTION 1 2: T ROUBLESHOOTING D ANGER Electrical Shoc k Hazard Disconnect electric bef ore service or maintenance. Heater m ust be connected t o a pr operly grounded electr ical source. Failur e to follo w these instructions can result in death or electr ical shock.
BH-S ERIES I NSTA LLATION , O PERAT ION AN D S ER VICE M ANUAL 52 1 2.1 T rou bleshootin g Flow Chart Replace pr essure sw itch YES NO Replace transf ormer. YES NO Remov e obstruction. YES NO YES NO Replace b lower . NO YES NO YES NO YES YES NO NO YES Is there spark at the igniter? YES NO NO Is the blow er obstructed? Remov e obstruction.
SECTION 12 : T ROUBLE SHO OTING 53.
BH-S ERIES I NSTA LLATION , O PERAT ION AN D S ER VICE M ANUAL 54 1 2.2 Manifold Gas P ressur e Set tin g 1 0 .5" Natural Propane 6 5 4 3 2 1 0 1 2 3 4 5 6 3.
SECTION 1 3: R EPLACEMENT P ARTS 55 SECTION 1 3: REPLACEMENT P AR TS Carbon Mono xide Hazard W ARNING Use only genuine R OBERTS GORDON ® replacement parts per this installation, operation and service manual. Failur e to follo w these instructions can r esult in death, electric shock, injury or property damage .
BH-S ERIES I NSTA LLATION , O PERAT ION AN D S ER VICE M ANUAL 56 B low e r Out l et G as k et R EA R V IE W T O P V IE W D SI I g niti o n M o du l e B low e r Asse m b y E l e c t ro de Bu r ne r Cu.
SECTION 1 3: R EPLACEMENT P ARTS 57 Description Pa r t Nu m b er Mica Window As sembly 02553203 Electr ode Gasket 0255850 1 T ube Gasket 02568200 Burner Cup Assembly 03020 1 00 Gas V alv e (Natural) 9.
BH-S ERIES I NSTA LLATION , O PERAT ION AN D S ER VICE M ANUAL 58 SECTION 1 4: GENERAL SPECIF ICATIONS 1 4.1 Material Specificat ions 1 4.1 .1 Ref lector s .024 Alumin um (Optional .024 Stai nless St eel T ype 304) 1 4.2 Heater Specif ications 1 4.2.1 I g niti on F ully automat ic spark ignition wit h saf ety shut-of f .
SECTION 15: T HE ROBERTS GORDON ® GORDONRA Y ® BH W ARR ANTY 59 SECTION 1 5: THE ROBER TS GORDO N ® GORDONRA Y ® BH W ARRANTY RO BERTS-GORDON LLC WILL P A Y FOR: Within 36 mont hs from date of pur.
.
® O WNER W ARRANTY RE GISTR A TION C ARD About the Owner: Name:__________________________________________________________________________________________________ Add r e ss :_________________________.
.
.
Infrar ed Heating Maintain c lear ance t o the side and c lear ance below the heat er fr om v ehic les and comb ustible mat er ials. www .rg-inc.com Print ed in U.S.A. P/ N 9103791 2 Re v . H At tach this infor mation to a w all near the ROBER TS GORDON ® heater .
Een belangrijk punt na aankoop van elk apparaat Roberts Gorden Linear Heater (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Roberts Gorden Linear Heater heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Roberts Gorden Linear Heater vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Roberts Gorden Linear Heater leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Roberts Gorden Linear Heater krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Roberts Gorden Linear Heater bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Roberts Gorden Linear Heater kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Roberts Gorden Linear Heater . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.