Server RSV -S5 User Manual.
Server R S V - S 5 U s e r M a n u a l Content 1 WELCOME .................................................................................... 3 1.1 PRECAUTION ............................................................................................
Server R S V - S 5 U s e r M a n u a l 4.2.7 RAID GROUPS OVERVIEW ..................................................................................................... 68 4.3 ADDITIONAL MENU COMMAND S ..................................................
Server R S V - S 5 U s e r M a n u a l 1 WELCOME RSV -S5 enhances your data storage by combini ng advanced RAID1 featur es typicall y seen on high-end data systems with low cost/h igh capacity Serial A T A drives.
Server R S V - S 5 U s e r M a n u a l 1.3 EASE OF USE The RSV -S5 utility offers an easy to use utility for cr ea ting and managing your stor age. It also supports the latest SA T A enhancements including SA T A-II Port Multiplier support, and up to 3Gbit/sec tr ansfer rates on contr ollers that support th at speed.
Server R S V - S 5 U s e r M a n u a l 2 AN INTRODUCTION TO RAID 2.1 RAID VOLUMES RAID technology allo ws one or mor e disks to be co mbined into a logical volu me which provides greater performance and/or p rotection tha n standard di sk drives.
Server R S V - S 5 U s e r M a n u a l F i g u r e 1 : D i v i d i n g D i s k s i n t o M e m b e r s 2.3 RAID LEVELS 2.3.1 DISK STRIPING (RAID 0) Striping is a performance- oriented, non-redund ant data mapping technique. While St riping is discussed as a RAID Grou p type, it is does not pr ovide any faul t tolerance.
Server R S V - S 5 U s e r M a n u a l requir es four drives . The drives are assigned as two sets of str iped pairs. The data is written to RAID Gr oup A, which is mirror ed (RAID 1) and provi des data redundan cy . Alternating blocks of data ar e then striped acr oss anothe r RAID 1 mirror ed set, shown as S et B in the figure abo ve.
Server R S V - S 5 U s e r M a n u a l 2.3.6 SINGLE DRIVE / SEGMENT The single drive i s a virtual disk that can either be an entir e disk drive or a segm ent of a single disk d rive. Single drive is the “Contig uous” configuration opti on when creating RAID Groups (or sets) in the SA T ARAID5 software.
Server R S V - S 5 U s e r M a n u a l gentl y insert the drive unti l the drive is fully insert ed, and shut the tray handl e to seat the drive se curely . Atta ch one end of the AC powe r cord to RSV -S5 and the other end to the pr oper AC rec eptacle.
Server R S V - S 5 U s e r M a n u a l Select Specify a location , than click Next> . Click Brows e… to select to driver path , than click OK. Click Next> to install the Silicon Image Sil3132 SoftRaid 5 Contr oller driver .
Server R S V - S 5 U s e r M a n u a l Click Ye s to pass the Microsoft digital signa ture and continue th e installation. When the Silicon Image Sil3132 SoftRaid 5 Controller install ation has completed, click Finish , and begin to the Silicon Image’ s Pseudo Processor Device driver installation.
Server R S V - S 5 U s e r M a n u a l Select Search for a suitable driver for my devic e (recommen ded), than click Next>. Select Specify a location , than click Next> .
Server R S V - S 5 U s e r M a n u a l Click Next> to install the Silicon Image’ s Pseudo Processor Device driver . When the Silicon Image’ s Pseudo Processor Device installati on has completed, click Fini sh.
Server R S V - S 5 U s e r M a n u a l 3.3.2 INST ALLING SA T ARAID5 UTILITY Follow the descripti ons below , and step by step to complete th e installation. Open the Setup and Install ation Repository CD and select t he SA T ARAID5 Array Manager softwar e from the Utility folder .
Server R S V - S 5 U s e r M a n u a l Select Place shortcut on Desktop , than click Next> to create a shor tcut on the desktop. Click Next> to use the default installation folder .
Server R S V - S 5 U s e r M a n u a l When SA T ARAID5 installation has completed, click Clos e to exit. Select I agree the terms in the license agr eement, than click Next> to begin the Java platform installation. Select Ty p i c a l , than click Next>.
Server R S V - S 5 U s e r M a n u a l When Java platform insta llation has completed, click Finish to exit. Select Start > Programs > Silicon Image > SA T ARaid5Manager to start the Ar ray Manager softwa re. 3.3.3 DISK DRIVE MODE SETUP Please r efer to the chapter 4.
Server R S V - S 5 U s e r M a n u a l Select Disk Management under Storage to view the disk drives. When Write Signatur e and Upgrade Disk Wizar d appears, click Next>.
Server R S V - S 5 U s e r M a n u a l Do no t click any disk to upgrade to dynamic di sk, than click Next> . When the Write Signature and Up grade Disk Wizar d has completed, click Finish. Right-cli ck on the Unallocated partition and select Create Partition … from the pop-up menu.
Server R S V - S 5 U s e r M a n u a l Click Next> to create a p artition on a basic disk. Selec t the partition type y ou want to cr eate, than click Next> .
Server R S V - S 5 U s e r M a n u a l Assig n the drive letter or path you want to cr eate, than click Next> . Click Format this partition with the following settings and Perform a Quick Format , setup the File system to use, Allocation unit size, V olume label, than click Ne xt>.
Server R S V - S 5 U s e r M a n u a l The sta tus of the newly cr eated p artition in the Disk Management window should change to Formatting and the percentage compl ete will be displayed. Depending upon the si ze of the partition, the format process may take several minut es.
Server R S V - S 5 U s e r M a n u a l 3.4 INST ALLING ON WINDOWS XP (32/64-BIT) 3.4.1 INST ALLING SA T A RAID HOST BUS ADAPTER Follow the descripti ons below , and step by step to complete th e setup. Inse rt the Setup and Installa tion Repository CD in the C D-ROM drive.
Server R S V - S 5 U s e r M a n u a l Select Sear ch for the best driver in ther e location, Include thi s location in the sear ch, and click Brows e to select the drive r path, than click Next>.
Server R S V - S 5 U s e r M a n u a l 3.4.2 INST ALLING SA T ARAID5 UTILITY Follow the descripti ons below , and step by step to complete th e installation. Open t he Setup and Installation Repository CD an d select t he SA T ARAID5 Array Manager softwar e from the Utility folder .
Server R S V - S 5 U s e r M a n u a l Click Next> to begin setup. Select I Agree, than click Next>. Select Place shortcut on Desktop , than click Next> to create a shortcut on the desktop.
Server R S V - S 5 U s e r M a n u a l Click Next> to use the default installation folder . Click Next> to begin the install ation. When SA T ARAID5 installation has co mp leted, click Close to exit.
Server R S V - S 5 U s e r M a n u a l Select I accept the terms in the license agr eement , than click Next> to begin the Ja va platform installation. Select Ty p i c a l , than click Next>. When Java platform insta llation has completed, click Finish to exit.
Server R S V - S 5 U s e r M a n u a l 3.4.3 DISK DRIVE MODE SETUP Please r efer to the chapter 4. 3.4.4 ALLOCA TING P A RTITIONS ON WIN DOWS XP 32-BIT Before cr eating an y partitions, RAID gr oups must first b e created using the SA T ARaid5Manager utility .
Server R S V - S 5 U s e r M a n u a l When Initialize and Convert Disk Wi zard appears, click Next> . Select the new di sk to initialize, than click Next>.
Server R S V - S 5 U s e r M a n u a l When the Initialize and Convert Disk Wizard has completed, click Finish. Right-cli ck on the Unallocated partition and select New Partition … from the pop-up menu. Click Next> to cre ate a partition on a basic disk.
Server R S V - S 5 U s e r M a n u a l Selec t the partition type y ou want to cr eate, than click Next>. Specify t he partition size y ou want to create, than click Next>. Assig n the drive letter or path you want to cr eate, than click Next>.
Server R S V - S 5 U s e r M a n u a l Click Format this partition with the following settings and Perform a quick format, setup the File system, Allocatio n unit size, V olume label , than click Nex t> . Whe n the N ew Partition Wizar d has completed, click Finish.
Server R S V - S 5 U s e r M a n u a l The status of the ne wly created pa rtition in the Disk Managem ent window should change to Formatting an d the per centage complete will be displayed. Depending upon the size of the partition, the format pr ocess may take several minutes.
Server R S V - S 5 U s e r M a n u a l 3.4.5 ALLOCA TING P A RTITIONS ON WIN DOWS XP 64-BIT Before cr eating an y partitions, RAID gr oups must first b e created using the SA T ARaid5Manager utility . Once the sets have been creat ed, allow the system to load Windows.
Server R S V - S 5 U s e r M a n u a l When Initialize and Convert Disk Wi zard appears, click Next>. Select the new di sk to initialize, than click Next> .
Server R S V - S 5 U s e r M a n u a l When the Initialize and Convert Disk Wizard has completed, click Finish . Windows 64-bit system supports GPT disk which supports disk volume greater than 2TB. Right-cli ck on the Basic disk and select Convert to GPT disk from the pop-up menu.
Server R S V - S 5 U s e r M a n u a l Right-cli ck on the Unallocated partition and select New Partition … from the p op-up menu. Click Next> to cre ate a partition on a basic disk.
Server R S V - S 5 U s e r M a n u a l Specify t he partition size yo u want to cr eate, than c lick Next>. Assig n the drive letter or path you want to cr eate, than click Next>.
Server R S V - S 5 U s e r M a n u a l When the New Partition Wizard has completed, click Finish. The status of the ne wly created pa rtition in the Disk Managem ent window should change to Formatting an d the per centage complete will be displayed. Depending upon the size of the part ition, the format pr ocess may take several minutes.
Server R S V - S 5 U s e r M a n u a l Repeat the above pr ocedur e as neede d for any other partitions. Close the Data Mana gement window by clicking on the small boxe d “X” in the top right corner of the window . Click on the “My Comp uter” icon on the Desktop.
Server R S V - S 5 U s e r M a n u a l Select Install from a list or speci fic location (Advanced), than clic k Next> . Select Search for the best driver in t here locatio n, Include this location in the sear ch , and click Brow se to select the driver pa th, than click Next> .
Server R S V - S 5 U s e r M a n u a l When the installation has completed, click Finish. 3.5.2 INST ALLING SA T ARAID5 UTILITY Follow the descripti ons below , and step by step to complete th e installation. Open the Setup and Install ation Repository CD and select t he SA T ARAID5 Array Manager softwar e from the Utility folder .
Server R S V - S 5 U s e r M a n u a l Click Next> to begin setup. Select I Agree, than click Next>. Select Place shortcut on Desktop, than click Next> to create a shortcut on the desktop.
Server R S V - S 5 U s e r M a n u a l Click Next> to use the default installation folder . Click Next> to begin the install ation. When SA T ARAID5 installation has completed, click Clos e to exit.
Server R S V - S 5 U s e r M a n u a l Select I accept the terms in the license agr eement , than click Next> to beg in the Java platform installation. Select Ty p i c a l , than click Next>. When Java platform insta llation has completed, click Finish to exit.
Server R S V - S 5 U s e r M a n u a l 3.5.3 DISK DRIVE MODE SETUP Please r efer to the chapter 4. 3.5.4 ALLOCA TING P A RTITIONS Before cr eating an y partitions, RAID gr oups must first b e created using the SA T ARaid5Manager utility . Once the sets have been creat ed, allow the system to load Windows.
Server R S V - S 5 U s e r M a n u a l When I nitialize and Convert Disk Wi zard appears, click Next>. Select the new di sk to initialize, than click Next>.
Server R S V - S 5 U s e r M a n u a l When the Initialize and Convert Disk Wizard has completed, click Finish. Windo ws Server 2003 SP1 or later system supports GPT disk whi ch supports disk volume gr eater than 2TB. Right-cli ck on the Basic disk an d select Convert to GPT disk from the pop-up menu.
Server R S V - S 5 U s e r M a n u a l Right-cli ck on the Unallocated partition and select New Partition … from the pop-up menu. Click Next> to create a p artition on a basic disk.
Server R S V - S 5 U s e r M a n u a l Specify t he partition size y ou want to create, than click Next>. Assig n the drive letter or path you want to cr eate, than click Next>. Click Format this partition with the following settings and Perform a quick format , setup the File system, Allocatio n unit size, V olume label, than click Next>.
Server R S V - S 5 U s e r M a n u a l When the New Partition Wizard has completed, click Finish. The status of the ne wly created pa rtition in the Disk Managem ent window should change to Formatting an d the per centage complete will be displayed. Depending upon the size of the partition, the format pr ocess may take several minutes.
Server R S V - S 5 U s e r M a n u a l Repea t the above pr ocedur e as needed for an y other partition s. Close the Data Managem ent window by clicking on the small boxe d “X” in the top right corner of the window . Click on the “My Comp uter” icon on the Desktop.
Server R S V - S 5 U s e r M a n u a l Insert the disc that cam e with your RAID Co ntrolle r , than click Next. When the installation has completed, click Clo se.
Server R S V - S 5 U s e r M a n u a l 3.6.2 INST ALLING SA T ARAID5 UTILITY Follow the descripti ons below , and step by step to complete th e installation. Open t he Setup and Installation Repository CD an d select t he SA T ARAID5 Array Manager softwar e from the Utility folder .
Server R S V - S 5 U s e r M a n u a l Click Next> to begin setup. Select I Agree, than click Next>. Select Place shortcut on Desktop , than click Next> to create a shortcut on the desktop.
Server R S V - S 5 U s e r M a n u a l Click Next> to use the default installation folder . Click Next> to begin the installatio n. When SA T ARAID5 installation has completed, click Close to exit.
Server R S V - S 5 U s e r M a n u a l Select I accept the terms in the license agr eement, than click Next> t o begin the Java platform installation. Select Ty p i c a l , than click Next>. When Java platform insta llation has completed, click Finish to exit.
Server R S V - S 5 U s e r M a n u a l 3.6.3 DISK DRIVE MODE SETUP Please r efer to the chapter 4. 3.6.4 ALLOCA TING P A RTITIONS Before cr eating an y partitions, RAID gr oups must first b e created using the SA T ARaid5Manager utility . Once the sets have been creat ed, allow the system to load Windows.
Server R S V - S 5 U s e r M a n u a l When Initialize Disk Wizar d appears, sel ect Disk 1 and GPT (GUID Partition T able), than click OK. Windows V ista system supports GPT disk which supports disk volume greater than 2TB. Right-cli ck on the Unallocated partition and select New Single V olume … from the pop-up menu.
Server R S V - S 5 U s e r M a n u a l Click Next> to create the partition. Specify t he partition size y ou want to create, than click Next>. Assig n the drive letter or path you want to cr eate, than click Next>.
Server R S V - S 5 U s e r M a n u a l Click Format this partition with the following setti ngs and Perform a quick format, setup the File system, Allocatio n unit size, V olume label, than click Next>. When the New Partition Wizard has completed, click Finish.
Server R S V - S 5 U s e r M a n u a l The status of the ne wly created pa rtition in the Disk Managem ent window should change to Formatting an d the per centage complete will be displayed. Depending upon the size of the partition, the format pr ocess may take several minutes.
Server R S V - S 5 U s e r M a n u a l 4 SA T ARAID5 ARRA Y MANAGER 4.1 OVERVIEW The SA T ARAID5 Array Manager is the Graphi cal User Interfa ces (GUI) which allows you to create and manage RAID volumes. The Manager initia lly sho ws two windows as se en below .
Server R S V - S 5 U s e r M a n u a l 4.2 CREA TING RAID GROUPS T o begin creating a new RAID Gr oup, select “Cr eate RAID Gr oup” from the RAI D Group men u or right click on a contr oller in the RAID Gro ups window and sel ect “Create RAI D Group” fr om the pop-up menu.
Server R S V - S 5 U s e r M a n u a l 4.2.3 STRIPED RAID GROUPS Striped RAID Groups allow the user to select minimum of 2 or more disks for ea ch member of the volume. Enter the desired values and pr ess Create to cr eate the RAID Group (Example below).
Server R S V - S 5 U s e r M a n u a l 4.2.5 MIRRORED STRIPED RAID G ROUPS Mirror ed Striped RAID G roups allo w the user to select minimum of 4 disks for each member of the volume. Enter the desired values and pr ess Create to cr eate the RAID Group (Example below).
Server R S V - S 5 U s e r M a n u a l 4.2.7 RAID GROUPS OV ERVIEW RAID Groups allow Enter values in all fie lds and click Cr eate to cr eate the RAID Gr oup.
Server R S V - S 5 U s e r M a n u a l RAID Level Min # of Disks 0 2 1 2 5 3* 10 4* Contiguous 1 Concatenated 1 Once all parameters have been selected, se lect “Cr eat e” to create the RAID Group. When finished, pr ess Cancel to exit the Cr eate RAID Group Dial og.
Server R S V - S 5 U s e r M a n u a l 4.3.1 CONFIGURA TION SA T ARAID5 configuration options includ e customization of the set tings for Log File, Popup, and Advanced Options .
Server R S V - S 5 U s e r M a n u a l - Error Level - The following even ts will trigger a popup window: Erro rs - Disable All - No events will trigger a popup window . Advanced Options The Advanced Optio ns tab is used to contr ol advanced featu res of the RAID driver .
Server R S V - S 5 U s e r M a n u a l The Advanced Optio ns tab allows you to enable the following ad vanced feature s. FEA TURE EXPLANA TION Legacy (Bootable) Support When this feature is selected, Legacy Support menu will be available in the menu bar .
Server R S V - S 5 U s e r M a n u a l 4.3.4 DELETE SP ARE This menu option displays a dialog box to select (highlight) one or mor e spare drives to delete.
Server R S V - S 5 U s e r M a n u a l 4.3.5 DELETE MEMBER This menu option displays a dialog box to select (hig hlight) RAID g roup members to delete. Because RAID 0 is not fault tolerant, RAID 0 members ar e not shown i n the list. Note: Deleting members will demote the RAID gr oup to a non-fault-tolerant RAID gr oup.
Server R S V - S 5 U s e r M a n u a l 4.3.8 DEVICE SUMMAR Y This command displays the Segmen t Summary wind ow to show all physical de vices’ segment s.
Server R S V - S 5 U s e r M a n u a l 4.3.9 CREA TE RAID GROUP This command displays a dialog b ox to let user verify a raid type than display C reate RAID Gr oup dialog box. 4.3.10 REBUILD RAID GROUP This command displays a dialog b ox to let user choose a r eplacement segmen t to rebuild a non-fault tolerant RAID group.
Server R S V - S 5 U s e r M a n u a l 4.3.11 DELETE RAID GROUP This command displays a dialog b ox to let user choose RAID gr oups to delete. 4.3.12 BRING RAID GROUP ONLINE This menu option is not available in thi s product.
Server R S V - S 5 U s e r M a n u a l Fields This command displays a dialog box to let user choo se which fields will be shown in the RAID Gr oup Summary window . 4.3.14 T ASK MANAGER This command displays the T ask Manager window . Th e T ask Manager window lists all RAID and disk management task s that have been started and/or done.
Server R S V - S 5 U s e r M a n u a l Exit This command closes the T ask Summary window . Sorting This command displa ys a dialog box to let u ser choose up to 3 it ems to sort task item s in the task li st. Fields This command displays a dialog box to let user choo se which fields will be shown in the task list.
Server R S V - S 5 U s e r M a n u a l Delete This command displays a dialog b ox to let user delete the selecte d task items fr om the tas k list in T ask Summary window . The following dialog box will po p up to get confirmati on fr om the user . 4.
Server R S V - S 5 U s e r M a n u a l Fields This command displays a dialog box to let user choo se which fields will be shown in the event log. 4.3.16 RESOURCES This command displays the Resour ce Informa tion wi ndow . This feature is for debugging p urpose only .
Server R S V - S 5 U s e r M a n u a l 4.3.19 ABOUT This command displays a dialog b ox with mor e information about the SA T ARAID5 program, including the revisi on level. Thank you for pur chasing a quality Rosewill Pro duct. Please reg ister your pro duct at : www .
Een belangrijk punt na aankoop van elk apparaat Rosewill RSV-S5 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Rosewill RSV-S5 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Rosewill RSV-S5 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Rosewill RSV-S5 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Rosewill RSV-S5 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Rosewill RSV-S5 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Rosewill RSV-S5 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Rosewill RSV-S5 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.