NL
Sharp logo
Officiële handleiding

Sharp EL-5230

132 pagina's·4.6 MB·Rekenmachine·PDF·EN
Sharp EL-5230
Inhoudsopgave 80 secties OPERATION MANUAL · PROGRAMMABLE SCIENTIFIC CALCULATOR · EL-5230 EL-5250 · SHARP EL-5230/5250 · … TonenVerbergen
OPERATION MANUALp.1PROGRAMMABLE SCIENTIFIC CALCULATORp.1EL-5230 EL-5250p.1SHARP EL-5230/5250p.3Introductionp.3Chapter 1:p.3Before You Get Startedp.3Chapter 2:p.3General Informationp.3Chapter 3:p.3Scientific Calculationsp.3Chapter 4:p.3Statistical Calculationsp.3Chapter 5:p.3Equation Solversp.3Chapter 6:p.3Complex Number Calculationsp.3Chapter 7:p.3Programmingp.3Chapter 8:p.3Application Examplesp.3Appendixp.3Operational Notesp.10NOTICEp.10Key Notation in This Manualp.11Note:p.11Examplep.11NORMAL MODE 0. πRŒ˚–10_p.11Chapter 1 Before You Get Startedp.13Preparing to Use the Calculatorp.13Resetting the calculatorp.13zALL DATA CL?z z YES¬[DEL] z z NO¬[ENTER]zp.13LCD CONTRAST [+] [-] DARK® ¬LIGHTp.13The Hard Casep.14Calculator Layout and Display Symbolsp.15Calculator layoutp.15Displayp.16Operating Modesp.17Selecting a modep.17What you can do in each modep.17A Quick Tourp.18Turning the calculator on and offp.18Entering and solving an expressionp.18NORMAL MODE 0. 8Œ©‰3-7˚–10.5_p.180. 8Œ©‰3-7˚–10.5= 110.4504172p.18Editing an expressionp.198Œ©‰3-7˚–10.5= 110.4504172 8Œ©‰3-7˚–10.5p.19110.4504172 8Œ©‰(3-7˚–10.5p.198Œ©‰(3-7˚–10.5 )= 7.317272966p.19Using variablesp.20Example 1p.20NORMAL MODE 0. 2„Ò_p.20Example 2p.20NORMAL MODE 0. π_p.20NORMAL MODE 0. πRŒ_p.200. πRŒ= 201.0619298p.21Using simulation calculations (ALGB)p.21NORMAL MODE 0. 1ı3πRŒH_p.211ı3πRŒHp.211ı3πRŒH=p.22670.2064328p.221ı3πRŒH H=8_p.22678.5840132p.22Using the solver functionp.230. AnsÒV 678.5840132p.23AnsÒV 678.5840132 V=1ı3πRŒH_p.23V=1ı3πRŒHp.23V=z678.5840132p.23Other featuresp.24Chapter 2 General Informationp.25Clearing the Entry and Memoriesp.25Memory clear keyp.25<M-CLR> ƒDISP ⁄MEMORY ¤STAT ‹RESETp.25Editing and Correcting an Equationp.26Cursor keysp.26NORMAL MODE 0. 123456_p.26Overwrite mode and insert modep.26Delete keyp.27Multi-entry recall functionp.273˚5+3˚2= 21. 3˚5+2p.27
Page 1 of the Sharp EL-5230 user manual — OPERATION MANUAL
Pagina 1 · klik om te vergroten
Pagina 1

OPERATION MANUAL

PROGRAMMABLE SCIENTIFIC CALCULATOR

EL-5230 EL-5250

®

Page 2 of the Sharp EL-5230 user manual — OPERATION MANUAL
Pagina 2 · klik om te vergroten
Pagina 2
Page 2 of the Sharp EL-5230 user manual — OPERATION MANUAL
Page 3 of the Sharp EL-5230 user manual — Chapter 1:
Pagina 3 · klik om te vergroten
Pagina 3

SHARP EL-5230/5250

Programmable Scientific Calculator

Introduction

Chapter 1:

Before You Get Started

Chapter 2:

General Information

Chapter 3:

Scientific Calculations

Chapter 4:

Statistical Calculations

Chapter 5:

Equation Solvers

Chapter 6:

Complex Number Calculations

Chapter 7:

Programming

Chapter 8:

Application Examples

Appendix

Page 4 of the Sharp EL-5230 user manual — SHARP EL-5230/5250
Pagina 4 · klik om te vergroten
Pagina 4
Page 4 of the Sharp EL-5230 user manual — SHARP EL-5230/5250
Page 5 of the Sharp EL-5230 user manual — SHARP EL-5230/5250
Pagina 5 · klik om te vergroten
Pagina 5
Page 5 of the Sharp EL-5230 user manual — SHARP EL-5230/5250
Page 6 of the Sharp EL-5230 user manual — SHARP EL-5230/5250
Pagina 6 · klik om te vergroten
Pagina 6
Page 6 of the Sharp EL-5230 user manual — SHARP EL-5230/5250
Page 7 of the Sharp EL-5230 user manual — SHARP EL-5230/5250
Pagina 7 · klik om te vergroten
Pagina 7
Page 7 of the Sharp EL-5230 user manual — SHARP EL-5230/5250
Page 8 of the Sharp EL-5230 user manual — SHARP EL-5230/5250
Pagina 8 · klik om te vergroten
Pagina 8
Page 8 of the Sharp EL-5230 user manual — SHARP EL-5230/5250
Page 9 of the Sharp EL-5230 user manual — Introduction
Pagina 9 · klik om te vergroten
Pagina 9

Introduction

Thank you for purchasing the SHARP Programmable Scientific Calculator Model EL-5230/5250. After reading this manual, store it in a convenient location for future reference.

  • Unless the model is specified, all text and other material appearing in this manual applies to both models (EL-5230 and EL-5250).
  • Either of the models described in this manual may not be available in some countries.
  • Screen examples shown in this manual may not look exactly the same as what is seen on the product. For instance, screen examples will show only the symbols necessary for explanation of each particular calculation.
  • All company and/or product names are trademarks and/or registered trademarks of their respective holders.
Page 10 of the Sharp EL-5230 user manual — NOTICE
Pagina 10 · klik om te vergroten
Pagina 10

Operational Notes

  • Do not carry the calculator around in your back pocket, as it may break when you sit down. The display is made of glass and is particularly fragile.
  • Keep the calculator away from extreme heat such as on a car dashboard or near a heater, and avoid exposing it to excessively humid or dusty environments.
  • Since this product is not waterproof, do not use it or store it where fluids, for example water, can splash onto it. Raindrops, water spray, juice, coffee, steam, perspiration, etc. will also cause malfunction.
  • Clean with a soft, dry cloth. Do not use solvents or a wet cloth.
  • Do not drop it or apply excessive force.
  • Never dispose of batteries in a fire.
  • Keep batteries out of the reach of children.
  • This product, including accessories, may change due to upgrading without prior notice.

NOTICE

  • SHARP strongly recommends that separate permanent written records be kept of all important data. Data may be lost or altered in virtually any electronic memory product under certain circumstances. Therefore, SHARP assumes no responsibility for data lost or otherwise rendered unusable whether as a result of improper use, repairs, defects, battery replacement, use after the specified battery life has expired, or any other cause.
  • SHARP will not be liable nor responsible for any incidental or consequential economic or property damage caused by misuse and/ or malfunctions of this product and its peripherals, unless such liability is acknowledged by law.

Introduction

Page 11 of the Sharp EL-5230 user manual — NORMAL MODE 0. πRŒ˚–10_
Pagina 11 · klik om te vergroten
Pagina 11

Key Notation in This Manual

In this manual, key operations are described as follows:

To specify e x@ " .....................
To specify Ini
To specify F; F ...........................
To specify d/c@ F .....................
To specify a b/ck
To specify H; H...........................
To specify iQ ..............................

Functions that are printed in orange above the key require @ to be

pressed first before the key. When you specify the memory (printed in blue above the key), press

; first. Alpha-numeric characters for input are not shown as keys but as regular alpha-numeric characters. Functions that are printed in grey (gray) adjacent to the keys are effective

in specific modes.

Note:

  • To make the cursor easier to see in diagrams throughout the manual, it is depicted as ‘_’ under the character though it may actually appear as a rectangular cursor on the display.

Example

Press j @ s ; R A k S 10

  • @ s and ; R means you have to press @ followed by ` key and ; followed by 5 key.

NORMAL MODE 0. πRŒ˚–10_

Introduction

Page 12 of the Sharp EL-5230 user manual — Key Notation in This Manual
Pagina 12 · klik om te vergroten
Pagina 12
Page 12 of the Sharp EL-5230 user manual — Key Notation in This Manual
Page 13 of the Sharp EL-5230 user manual — LCD CONTRAST [+] [-] DARK® ¬LIGHT
Pagina 13 · klik om te vergroten
Pagina 13

Chapter 1 Before You Get Started

Preparing to Use the Calculator

Before using your calculator for the first time, you must reset it and adjust its contrast.

Resetting the calculator

Sharp EL-5230 — Resetting the calculator diagram (page 13)
Afb. 1 · Resetting the calculator
1. Press the RESET switch located on the back of the calculator with the tip of a ballpoint pen or similar object. Do not use an object with a breakable or sharp tip.
  • If you do not see the message on the right, the battery may be installed incorrectly; refer to ‘Battery Replacement’ (See page 115.) and try installing it again.

zALL DATA CL?z z YES¬[DEL] z z NO¬[ENTER]z

2. Press y .

NORMAL MODE 0.

  • The initial display of the NORMAL mode appears.
3. Press @ o 0 and press + or - to adjust the display contrast until it is set correctly, then press j .

LCD CONTRAST [+] [-] DARK® ¬LIGHT

  • @ o means you have to press @ followed by S key.
  • See ‘The OPTION menu’ (See page 118.) for more information regarding optional functions.
Page 14 of the Sharp EL-5230 user manual — The Hard Case
Pagina 14 · klik om te vergroten
Pagina 14
Chapter 1Before You Get Started

The Hard Case

Your calculator comes with a hard case to protect the keyboard and display when the calculator is not in use.

Before using the calculator, remove the hard case and slide it onto the back as shown to avoid losing it.

When you are not using the calculator, slide the hard case over the keyboard and display as shown.

  • Firmly slide the hard case all the way to the edge.
  • The quick reference card is located inside the hard case.
  • Remove the hard case while holding with fingers placed in the positions shown below.
Page 15 of the Sharp EL-5230 user manual — Calculator layout
Pagina 15 · klik om te vergroten
Pagina 15
Chapter 1Before You Get Started

Calculator Layout and Display Symbols

Calculator layout

Sharp EL-5230 — Calculator layout diagram (page 15)
Afb. 2 · Calculator layout

2 Power ON/OFF and Clear key

1 Display screen: The calculator display consists of 14 × 3 line dot matrix display (5 × 7 dots per character) and a 2-digit exponent display per each line. 2 Power ON/OFF and Clear key: Turns calculator ON. To turn off the calculator, press @, then o. This key can also be used to clear the display. 3 Key operation keys: @: Activates the second function (printed in orange) assigned to the

next pressed key. ;Activates the variable (printed in blue) assigned to the next

pressed key.

4 Cursor keys: Enables you to move the cursor in four directions.

1 Display screen

Page 16 of the Sharp EL-5230 user manual — Display
Pagina 16 · klik om te vergroten
Pagina 16
Chapter 1Before You Get Started

Display

Sharp EL-5230 — Display diagram (page 16)
Afb. 3 · Display
  • During actual use, not all symbols are displayed at the same time.
  • Only the symbols required for the usage under instruction are shown in the display and calculation examples of this manual.

: Indicates some contents are hidden in the directions shown.

Press cursor keys to see the remaining (hidden) section.

BUSY : Appears during the execution of a calculation.

2ndF : Appears when @ is pressed.

xy / r θIndicates the mode of expression of results in the complex

calculation mode.

HYPIndicates that H has been pressed and the hyperbolic functions

are enabled. If @ > are pressed, the symbols ‘2ndF HYP’ appear, indicating that inverse hyperbolic functions are enabled.

ALPHA: Appears when ;, @ a, x or t is pressed.

FIX/SCI/ENG: Indicates the notation used to display a value.

DEG/RAD/GRAD: Indicates angular units.

: Appears when statistics mode is selected.

M : Indicates that a value is stored in the M memory.

Symbol · Dot matrix display · Exponent Mantissa

Page 17 of the Sharp EL-5230 user manual — What you can do in each mode
Pagina 17 · klik om te vergroten
Pagina 17
Chapter 1Before You Get Started

Operating Modes

This calculator has five operating modes to perform various operations. These modes are selected from the MODE key.

Selecting a mode

1. Press b .
Sharp EL-5230 — Selecting a mode diagram (page 17)
Afb. 4 · Selecting a mode

The menu display appears. Press d to display the next menu page.

2. Press 0 to select the NORMAL mode.

NORMAL MODE 0.

  • In the menu display, press the assigned number to choose or recall a selection.

What you can do in each mode

NORMAL mode:

Allow you to perform standard scientific calculations, Differential/Integral functions, N-base calculations, Solver function, Simulation calculation.

STAT (statistics) mode:

Allows you to perform statistical calculations.

PROG (program) mode:

Allows you to create and use programs to automate simple or complex calculations.

EQN (equation) mode:

Allows you to perform equation solvers, such as quadratic equation.

CPLX (complex) mode:

Allows you to perform arithmetic operations with complex numbers.

Page 18 of the Sharp EL-5230 user manual — 0. 8Œ©‰3-7˚–10.5= 110.4504172
Pagina 18 · klik om te vergroten
Pagina 18
Chapter 1Before You Get Started

A Quick Tour

This section takes you on a quick tour covering the calculator’s simple arithmetic operations and also principal features like the solver function.

Turning the calculator on and off

1. Press j at the top right of the keypad to turn the calculator on.

NORMAL MODE 0.

  • To conserve the batteries, the calculator turns itself off automatically if it is not used for several minutes.
2. Press @ o to turn the calculator off.
  • Whenever you need to execute a function or command which is written in orange above a key, press @ followed by the key.

Entering and solving an expression

Arithmetic expressions should be entered in the same order as they would normally be written in. To calculate the result of an expression, press e at the bottom right of the keypad; this has the same function as the ‘equals’ key on some calculators.

Example

Find the answer to the expression 82 ÷ 3 – 7 × -10.5

  • 1. 8 A z @ * 3 - 7 k S 10.5
  • This calculator has a minus key - for subtraction and a negative key S for entering negative numbers.
  • To correct an error, use the cursor keys l r u d to move to the appropriate position on the display and type over the original expression.

NORMAL MODE 0. 8Œ©‰3-7˚–10.5_

  • 2. Press e to obtain an answer.
  • While the calculator is computing an answer, BUSY is displayed at the above left of the display.
  • The cursor does not have to be at the end of an expression for you to obtain an answer.

0. 8Œ©‰3-7˚–10.5= 110.4504172

Page 19 of the Sharp EL-5230 user manual — 8Œ©‰(3-7˚–10.5 )= 7.317272966
Pagina 19 · klik om te vergroten
Pagina 19
Chapter 1Before You Get Started

Editing an expression

After obtaining an answer, you can go back to an expression and modify it using the cursor keys just as you can before the e is pressed.

Example

Return to the last expression and change it to 82 ÷ 3 – 7 × -10.5

  • 1. Press d or r to return to the last expression.
  • The cursor is now at the beginning of the expression (on ‘8’ in this case).
  • Pressing u or l after obtaining an answer returns the cursor to the end of the last expression.
  • To make the cursor easier to see in diagrams throughout the manual, it is depicted as ‘_’ under the character though it may actually appear as a rectangular cursor on the display.

8Œ©‰3-7˚–10.5= 110.4504172 8Œ©‰3-7˚–10.5

2. Press r four times to move the cursor to the point where you wish to make a change. • The cursor has moved four places to the right and is now flashing over ‘3’.

8Œ©‰3-7˚–10.5= 110.4504172 8Œ©‰3-7˚–10.5

  • 3. Press @ O .
  • This changes the character entering mode from ‘overwrite’ to ‘insert’.
  • When @ is pressed the 2ndF symbol should appear at the above of the display. If it does not, you have not pressed the key firmly enough.
  • The shape of the flashing cursor tells you which character entering mode you are in. A triangular cursor indicates ‘insert’ mode while a rectangular cursor indicates ‘overwrite’ mode.
4. Press ( and then move the cursor to the end of expression ( @ r ). • Note that the cursor has moved to the second line since the expression now exceeds 14 characters.

110.4504172 8Œ©‰(3-7˚–10.5

5. Press ) and e to find the answer for the new expression.

8Œ©‰(3-7˚–10.5 )= 7.317272966

Page 20 of the Sharp EL-5230 user manual — NORMAL MODE 0. πRŒ_
Pagina 20 · klik om te vergroten
Pagina 20
Chapter 1Before You Get Started

Using variables

You can use 27 variables (A-Z and θ) in the NORMAL mode. A number stored as a variable can be recalled either by entering the variable name or using t.

Example 1

Store 23 to variable R.

  • 1. Press j 2 1 then x .
  • j clears the display.
  • ALPHA appears automatically when you press x . You can now enter any alphabetic character or θ (written in blue above keys in the keypad).

NORMAL MODE 0. 2„Ò_

  • 2. Press R to store the result of 2 3 in R.
  • The stored number is displayed on the next line.
  • ALPHA disappears from the display.
0. 2„ÒR 8.

You can also store a number directly rather than storing the result of an expression.

Example 2

Find the area of a circle which has radius R.

2 S = πr

Enter an expression containing variable R (now equal to 8) from the last example.

1. Press j @ s then ; . • Whenever you need to use a character written in blue on the keypad, press ; beforehand. ALPHA will appear at the above of the display.

NORMAL MODE 0. π_

2. Press R and then A . • ALPHA disappears after you have entered a character.

NORMAL MODE 0. πRŒ_

r

Page 21 of the Sharp EL-5230 user manual — 1ı3πRŒH
Pagina 21 · klik om te vergroten
Pagina 21
Chapter 1Before You Get Started
3. Press e to obtain the result. Follow the same procedure as above, but press t instead of ; in step 1.

0. πRŒ= 201.0619298

You will get the same result.

Using simulation calculations (ALGB)

If you want to find more than one solution using the same formula or algebraic equation, you can do this quickly and simply by use of the simulation calculation.

Example

Find the volume of two cones: 1 with height 10 and radius 8 and 2 with height 8 and radius 9.

2 V = πr h 3 1 r

  • 1. Press j 1 k 3 @ s ; R A ; H to enter the formula.
  • Note that ‘1 3’ represents 1 over (i.e. divided by) 3.
  • Variables can be represented only by capital letters.

NORMAL MODE 0. 1ı3πRŒH_

  • 2. Press @ G ( I key) to finish entering the equation.
  • The calculator automatically picks out the variables alphabetically contained in the equation in alphabetical order and asks you to input numbers for them.
  • at the bottom of the display reminds you that there is another variable further on in the expression.

1ı3πRŒH

H=z 0.

3. Press 10 e to input the height and go on the next variable. • The calculator is now asking you to input a number for the next variable.

1ı3πRŒH

R=z 8.

h

Page 22 of the Sharp EL-5230 user manual — 1ı3πRŒH=
Pagina 22 · klik om te vergroten
Pagina 22
Chapter 1Before You Get Started
  • Note that, as the variable R already has a number stored in memory, the calculator recalls that number.
  • indicates that there is another variable earlier in the expression.
4. Press 8 to input the radius. Input of all variables is now complete.
5. Press e to obtain the solution.

1ı3πRŒH=

  • The answer (volume of cone ) is displayed on the third line.

670.2064328

6. Press e and 8 to input the height for cone . • The display returns to a value entry screen with ‘8’ substituted for ‘10’ in variable H.

1ı3πRŒH H=8_

7. Press e to confirm the change.

1ı3πRŒH R=z 8.

  • 8. Press 9 to enter the new radius then press e to solve the equation.
  • The volume of cone is now displayed.
  • In any step, press @ h to obtain the solution using the values entered into the variables at that time.

1ı3πRŒH=

678.5840132

Page 23 of the Sharp EL-5230 user manual — V=1ı3πRŒH
Pagina 23 · klik om te vergroten
Pagina 23
Chapter 1Before You Get Started

Using the solver function

You can solve any unknown variable in an equation by assigning known values to the rest of the variables. Let us compare the differences between the solver function and the simulation calculations using the same expres- sion as in the last example.

Example

What is the height of cone 3 if it has a radius of 8 and the same volume as cone 2 (r = 9, h = 8) in the last example?

2 V = πr h 3 1 r

9. Store the result of step 8 on the previous page in variable V. Press j twice and ; < x V.

0. AnsÒV 678.5840132

10. Input the equation (including ‘=’) in the NORMAL mode. Press ; V ; = then input the rest of the expression. You must press ; = ( m key), not e , to enter the = sign.

AnsÒV 678.5840132 V=1ı3πRŒH_

11. Press I 5 to move to the variable input display. • Note that the values assigned to the variables in the last example for the simulation calculations are retained and displayed.

V=1ı3πRŒH

H=z 8.

12. Press d to skip the height, and then press 8 e to enter the radius (R). • The cursor is now on V. The value that was stored in step 9 is displayed. (volume of cone 2 )

V=1ı3πRŒH

V=z678.5840132

13. Press u u to go back to the variable H. • This time the value of H from memory is also displayed.

V=1ı3πRŒH

H=z 8.

h

Page 24 of the Sharp EL-5230 user manual — Other features
Pagina 24 · klik om te vergroten
Pagina 24
Chapter 1Before You Get Started
  • 14. Press @ h to find the height of cone 3 .
  • Note that the calculator finds the value of the variable that the cursor is on when you press @ h .
  • Now you have the height of cone 3 that has the same volume as cone 2 .
  • R → and L → are the values computed by Newton's method, which is used to determine the accuracy of the solution.
Sharp EL-5230 — Other features diagram (page 24)
Afb. 5 · Other features

Right and left sides of the expression after substituting the known variables

Height of cone 3

Other features

Your calculator has a range of features that can be used to perform many calculations other than those we went through in the quick tour. Some of the important features are described below.

Statistical calculations:

You can perform one- and two- variable weighted statistical calculations, regression calculations, and normal probability calculations. Statistical results include mean, sample standard deviation, population standard deviation, sum of data, and sum of squares of data. (See Chapter 4.)

Equation solvers:

You can perform solvers of simultaneous linear equation with two/three unknowns or quadratic/cubic equation. (See Chapter 5.)

Complex number calculations:

You can perform addition, subtraction, multiplication, and division calculations. (See Chapter 6.)

Programming:

You can program your calculator to automate certain calculations. Each program can be used in either the NORMAL or NBASE program modes. (See Chapter 7.)

Page 25 of the Sharp EL-5230 user manual — <M-CLR> ƒDISP ⁄MEMORY ¤STAT ‹RESET
Pagina 25 · klik om te vergroten
Pagina 25

Chapter 2 General Information

Clearing the Entry and Memories

Saved equations*2

STAT VAR*5 A-Z, θ*1 Entry (Display)

Sharp EL-5230 — Clearing the Entry and Memories diagram (page 25)
Afb. 6 · Clearing the Entry and Memories

*1 Global variable memories. *2 Saved equations and local variables by the filing equations function *3 Last answer memory. *4 Statistical data (entered data) *5 n, x¯, sx, σx, Σx, Σx 2, ¯y, sy, σy, Σy, Σy 2, Σxy, a, b, c, r. *6 Will be cleared when changing between sub-modes in the STAT mode.

Note:

  • To clear one variable memory of global variable and local variable memories, press j x and then choose memory.

Memory clear key

Press @ P to display the menu.

<M-CLR> ƒDISP ⁄MEMORY ¤STAT ‹RESET

  • To initialize the display mode, press 0 . The parameters set as follows.
  • Angular unit: DEG (See page 26.)
  • Display notation: NORM1 (See page 26.)
  • N-base: DEC (See page 44.)
  • To clear all variables (excluding local variables of saved equations, statistical data and STAT variables), press 1 y .
  • To clear statistical data and STAT variables, press 2 y .
  • To RESET the calculator, press 3 y . The RESET operation will erase all data stored in memory and restore the calculator’s default setting.

Multi-entry

Page 26 of the Sharp EL-5230 user manual — Overwrite mode and insert mode
Pagina 26 · klik om te vergroten
Pagina 26
Chapter 2General Information

Editing and Correcting an Equation

Cursor keys

Incorrect keystrokes can be changed by using the cursor keys

(l r u d).

Example

Enter 123456 then correct it to 123459.

1. Press j 123456.

NORMAL MODE 0. 123456_

  • 2. Press y 9 e .
  • If the cursor is located at the right end of an equation, the y key will function as a backspace key.
  • You can return to the equation just after getting an answer by pressing the cursor keys. After returning to the equation, the following operations are useful;
0. 123459= 123459.

@ l or @ r: To jump the cursor to the beginning or the end of equation.

Overwrite mode and insert mode

  • Pressing @ O switches between the two editing modes: overwrite mode (default); and insert mode. A rectangular cursor indicates preexisting data will be overwritten as you make entries, while a triangular cursor indicates that an entry will be inserted at the cursor.
  • In the overwrite mode, data under the cursor will be overwritten by the number you enter. To insert a number in the insert mode, move the cursor to the place immediately after where you wish to insert, then make the desired entry.
  • The mode set will be retained until @ O is pressed or a RESET operation is performed.
Page 27 of the Sharp EL-5230 user manual — 3˚5+3˚2= 21. 3(5+2)
Pagina 27 · klik om te vergroten
Pagina 27
Chapter 2General Information

Delete key

  • To delete a number/function, move the cursor to the number/function you wish to delete, then press y . If the cursor is located at the right end of an equation, the y key will function as a backspace key.

Multi-entry recall function

Previous equations can be recalled in the NORMAL, STAT or CPLX mode. Up to 160 characters of equations can be stored in memory.

When the memory is full, stored equations are deleted in the order of the oldest first.

  • Pressing @ g will display the previous equation. Further pressing @ g will display preceding equations.
  • You can edit the equation after recalling it.
  • The multi-entry memory is cleared by the following operations: mode change, memory clear ( @ P 1 y ), RESET, N-base conversion.

Example

Input three expressions and then recall them.

2 3×5+2=

3 3×5+3×2=

1. Press j 3 ( 5 + 2 ) e
Sharp EL-5230 — Example diagram (page 27)
Afb. 7 · Example

3 k 5 + 2 e

3 k 5 + 3 k 2 e

2. Press @ g to recall the expression 3 .
3. Press @ g to recall the expression 2 .

3˚5+3˚2= 21. 3˚5+2

4. Press @ g to recall the expression 1 .

3˚5+3˚2= 21. 3(5+2)

1 3(5+2)=

Page 28 of the Sharp EL-5230 user manual — Setting the floating point numbers system in scientific notation
Pagina 28 · klik om te vergroten
Pagina 28
Chapter 2General Information

The SET UP menu

The SET UP menu enables you to change the angular unit and the display format.

  • Press @ J to display the SET UP menu.
  • Press j to exit the SET UP menu.

<SET UP> ƒDRG ⁄FSE ¤---

Determination of the angular unit

The following three angular units (degrees, radians, and grads) can be specified.

  • DEG(°) : Press @ J 0 0
  • RAD (rad): Press @ J 0 1
  • GRAD (g): Press @ J 0 2

Selecting the display notation and number of decimal places

Five display notation systems are used to display calculation results: Two settings of Floating point (NORM1 and NORM2), Fixed decimal point (FIX), Scientific notation (SCI) and Engineering notation (ENG).

  • When @ J 1 0 (FIX) or @ J 1 2 (ENG) is pressed, ‘TAB(0-9)?’ will be displayed and the number of decimal places (TAB) can be set to any value between 0 and 9.
  • When @ J 1 1 (SCI) is pressed, ‘SIG(0-9)?’ will be displayed and the number of significant digits (SIG) can be set to any value between 0 and 9. Entering 0 will set a 10-digit display.
  • When a floating point number does not fit in the specified range, the calculator will display the result using the scientific notation (exponential notation) system. See the next section for details.

Setting the floating point numbers system in scientific notation

The calculator has two settings for displaying a floating point number: NORM1 (default setting) and NORM2. In each display setting, a number is automatically displayed in scientific notation outside a preset range:

  • NORM1: 0.000000001 ≤ |x| ≤ 9999999999
  • NORM2: 0.01 ≤ |x| ≤ 9999999999
Page 29 of the Sharp EL-5230 user manual — Example 1
Pagina 29 · klik om te vergroten
Pagina 29
Chapter 2General Information
Sharp EL-5230 — Delete key diagram (page 29)
Afb. 8 · Delete key

and SIG set to 3 ] →[ENGineering notation

3÷1000= [Floating point (NORM1)] j 3 z 1000 e

Using Memories

The calculator uses global variable memories (A–Z and θ), local variable memories (maximum of nine variables per equation), and a last answer memory used when solving equations.

Using alphabetic characters

You can enter an alphabetic character (written in blue) when ALPHA is displayed at the top of the display. To enter this mode, press ;. To enter more than one alphabetic character, press @ a to apply the alphabet-lock mode. Press ; to escape from this mode.

NORMAL MODE 0.

Using global variables

You can assign values (numbers) to global variables by pressing x then A–Z and θ.

Example 1

Store 6 in global variable A.

1. Press j 6 x A.
0. 6ÒA 6.
  • There is no need to press ; because ALPHA is selected automatically when you press x .
Page 30 of the Sharp EL-5230 user manual — 0. 1.25 E –5ÒA1 0.0000125
Pagina 30 · klik om te vergroten
Pagina 30
Chapter 2General Information

Example 2

Recall global variable A.

1. Press t A. • There is no need to press ; because ALPHA is selected automatically when you press t .
6. A= 6.

Using local variables

Nine local variables can be used in each equation or program, in addition to the global variables. Unlike global variables, the values of the local variables will be stored with the equation when you save it using the filing equations function. (See page 58.)

To use local variables, you first have to assign the name of the local variable using two characters: the first character must be a letter from A to Z or θ and the second must be a number from 0 to 9.

Example

Store 1.25 x 10-5 as local variable A1 (in the NORMAL mode) and recall the stored number.

  • 1. Press @ v .
  • The VAR menu appears.
  • If no local variables are stored yet, ALPHA appears automatically and the calculator is ready to enter a name.

ƒz ‹ fl ⁄ › ‡ ¤ fi °

  • 2. Press A1 e .
  • ¬ shows that you have finished assigning the name A 1 .
  • To assign more names, press d to move the cursor to VAR 1 and repeat the process above.

¬ƒA¡ ‹ fl ⁄ › ‡ ¤ fi °

3. Press j . • This returns you to the previous screen.
4. Press 1.25 ` S 5 x @ v 0 .

0. 1.25 E –5ÒA1 0.0000125

Page 31 of the Sharp EL-5230 user manual — ¬ƒA¡ ‹ fl ⁄ › ‡ ¤ fi °
Pagina 31 · klik om te vergroten
Pagina 31
Chapter 2General Information
  • You do not need to enter an alphabetic character. Just specify the named local variable using a number from 0 to 8, or move the arrow to the appropriate variable the press e .
  • 5. Press @ v 0 e .
  • The value of VAR 0 will be recalled.
  • Alternatively you can recall a variable by moving the arrow to it then press e twice.

0.0000125 A1= 0.0000125

Note:

  • You can change the name of a local variable by overwriting it in the VAR menu. The cursor appears when r is pressed in the VAR menu.
  • Local variables not stored using the filing equations function will be deleted by mode selection or memory clear operation ( @ P 1 y ).
  • Local and global variables will be cleared by creating a new program, and editing and running a program.

Using variables in an equation or a program

Both global and local variables can be used directly in an equation or a program. Local variables are useful when you need to use variables such as X1 and X2 at the same time in another equation. The local variable names and their values can be saved in each equation. (See page 58.)

Example

Using A (6) and A1 (0.0000125) from the last two examples, solve the expression.

1 — A 1 – 1000A

1. Press j 1 k . • Start entering the expression.

NORMAL MODE 0. 1ı_

2. Press @ v .
Sharp EL-5230 — NORMAL MODE 0. 1ı_ diagram (page 31)
Afb. 9 · NORMAL MODE 0. 1ı_

¬ƒA¡ ‹ fl ⁄ › ‡ ¤ fi °

  • 3. Press 0 - 1000 ; A e .
  • The display returns automatically to the previous screen after you have chosen the local variable, and you can continue to enter the expression.
  • You do not need k if you use a variable. However, the variable must be a multiplier.
Page 32 of the Sharp EL-5230 user manual — Global variable M
Pagina 32 · klik om te vergroten
Pagina 32
Chapter 2General Information

Using the last answer memory

The calculator always keeps the most recent answer in ANS memory and replaces it with the new answer every time you press an ending instruction (e, x etc.). You may recall the last answer and use it in the next equation.

Example

Evaluate the base area (S = 32π) and volume of a cylinder (V = 5S) using the last answer memory.

  • 1. Press j 3 A @ s e .
  • The area of the base is now calculated.
  • The number 28.27433388 is held in ANS memory.
Sharp EL-5230 — Example diagram (page 32)
Afb. 10 · Example
2. Press j 5 ; < e . • You now have the volume of the cylinder.

The last answer is cleared (i.e. set to 0) if you press the RESET switch, change the mode or memory clear operation (@ P 1 y), but not if you turn the calculator off.

Global variable M

Using the M memory, in addition to the features of global variables, a value can be added to or subtracted from an existing memory value.

Sharp EL-5230 — Global variable M diagram (page 32)
Afb. 11 · Global variable M

j x M 0. 450. 250. 35. @ M t M 665.

$150×3:Ma +)$250:Mb=Ma+250 –)Mb×5% M

150 k 3 m 250 m t M k 5 @ %

  • m and @ M cannot be used in the STAT mode.

h = 5 · r = 3

Page 33 of the Sharp EL-5230 user manual — Notes:
Pagina 33 · klik om te vergroten
Pagina 33
Chapter 2General Information

Using memory in each mode

Mode ANS M A-L, N-Z, Local variables

NORMAL STAT PROG EQN CPLX

: Available : Unavailable

Notes:

  • Calculation results from the functions indicated below are automatically stored in memories replacing any existing values.
  • → r θ , → xy .................. R memory ( r ) θ memory ( θ ) X memory ( x ) Y memory ( y )
  • Use of t or ; will recall the value stored in memory using up to 14 digits in accuracy.
Page 34 of the Sharp EL-5230 user manual — Note:
Pagina 34 · klik om te vergroten
Pagina 34
Chapter 2General Information

Resetting the calculator

If you wish to clear all memories, variables, files and data, or if none of the keys (including j) will function, press the RESET switch located on the back of the calculator.

In rare cases, all the keys may cease to function if the calculator is subjected to strong electrical noise or heavy shock during use. Follow the instructions below to reset the calculator.

  • The RESET operation will erase all data stored in memory and restore the calculator's default setting.
1. Press the RESET switch located on the back of the calculator with the tip of a ballpoint pen or similar object. Do not use an object with a breakable or sharp tip.
  • A display appears asking you to confirm that you really want to reset the calculator.

zALL DATA CL?z z YES¬[DEL] z z NO¬[ENTER]z

2. Press y .

z ALL DATA z z CLEARED! z z z

  • All memories, variables, files and data are cleared.
  • The display goes back to the initial display in the NORMAL mode.

NORMAL MODE 0.

  • The calculator will revert to the very first settings that were made when you started to use the calculator for the first time.

Or, to cancel the operation, press e.

Note:

  • When corruption of data occurs, the reset procedure may automatically be initiated upon pressing the RESET switch.
  • Pressing @ P and 3 y can also clear all memories, variables, files and data as described above.
Page 35 of the Sharp EL-5230 user manual — Arithmetic operations
Pagina 35 · klik om te vergroten
Pagina 35

Chapter 3 Scientific Calculations

NORMAL mode

NORMAL mode is used for standard scientific calculations, and has the widest variety of functions. Many of the functions described in this chapter are also available for use in other modes. Press b 0 to select the NORMAL mode.

  • Differential/Integral functions, N-base functions, Solver functions and Simulation Calculation (ALGB) in this chapter are all performed in the NORMAL mode.
  • In each example of this chapter, press j to clear the display first. If the FIX, SCI or ENG indicator is displayed, clear the indicator by selecting ‘NORM1’ from the SET UP menu. Unless specified, set the angular unit as ‘DEG’. ( @ P 0 )

Arithmetic operations

Example Key operations Result

45+285÷3= j 45 + 285 z 3 e

18+6 = ( 18 + 6 ) z 15–8 ( 15 - 8 ) e

3.428571429

42×(–5)+120= 42 k S 5 + 120 e

(5×103)÷(4×10–3)= 5 ` 3 z 4 ` S 3 e

1250000.

Page 36 of the Sharp EL-5230 user manual — Functions
Pagina 36 · klik om te vergroten
Pagina 36
Chapter 3Scientific Calculations

Constant calculations

Sharp EL-5230 — Constant calculations diagram (page 36)
Afb. 12 · Constant calculations
  • In constant calculations, the addend becomes a constant. Subtraction and division behave the same way. For multiplication, the multiplicand becomes a constant.
  • In constant calculations, constants will be displayed as ∆ .

Functions

Sharp EL-5230 — Functions diagram (page 36)
Afb. 13 · Functions

0.866025403 sin60 [°]= j v 60 e

cos — [rad]= @ J 0 1 $ @ s k 4 e

tan–11 [g]= @ J 0 2 @ y 1 e @ P 0

  • The range of the results of inverse trigonometric functions
Sharp EL-5230 — Functions diagram (page 36)
Afb. 14 · Functions

θ = sin–1 x, θ = tan–1 x θ = cos–1 x

Page 37 of the Sharp EL-5230 user manual — Delete key
Pagina 37 · klik om te vergroten
Pagina 37
Chapter 3Scientific Calculations
Sharp EL-5230 — Delete key diagram (page 37)
Afb. 15 · Delete key

j ( H $ 1.5 + H v 1.5 ) A e

@ > t ( 5 z 7 ) e

8–2 – 34 × 52 = -2024.984375

@ * 49 - 4 @ D 81 e

Page 38 of the Sharp EL-5230 user manual — <MATH MENU-1> ƒabs ⁄ipart ¤int ‹fpart
Pagina 38 · klik om te vergroten
Pagina 38
Chapter 3Scientific Calculations

Math menu Functions

Other functions are available on this calculator besides the first and second functions on the key pad. These functions are accessed using the math function menu. The math menu has different contents for each mode. Press I to display the math menu. In the NORMAL mode, you can recall the following functions.

<MATH MENU-1> ƒabs ⁄ipart ¤int ‹fpart

<MATH MENU-2> ›ÒRAND fiSOLVE flΩsec ‡Ωmin

→ d

  • Switch the display using d u .
  • These math menus are not available for Differential/Integral functions, N-base functions, Solver functions and Simulation Calculation (ALGB).
Sharp EL-5230 — <MATH MENU-1> ƒabs ⁄ipart ¤int ‹fpart diagram (page 38)
Afb. 16 · <MATH MENU-1> ƒabs ⁄ipart ¤int ‹fpart
0. abs Displays the absolute value of a number.
1. ipart Displays the integer part only of a number.
2. int Displays the largest integer less than or equal to a number.
3. fpart Displays the fractional part only of a number.
4. ⇒ RAND Before using the Random Numbers of Random functions, designate 0.001 from 0.999 random number sequences available. The calculator can regenerate the same random numbers from the beginning. If you wish to go back to normal random numbers, press 0 I 4 .
Page 39 of the Sharp EL-5230 user manual — Delete key
Pagina 39 · klik om te vergroten
Pagina 39
Chapter 3Scientific Calculations
Sharp EL-5230 — Delete key diagram (page 39)
Afb. 17 · Delete key
Function Key operations Result 5SOLVE Enter the Solver function mode. (See page 52.)
6. Ω sec Sexagesimal numbers are converted to seconds notation. (See page 46.)
7. Ω min Sexagesimal numbers are converted to minutes notation. (See page 46.)
Page 40 of the Sharp EL-5230 user manual — Differential function
Pagina 40 · klik om te vergroten
Pagina 40
Chapter 3Scientific Calculations

Differential/Integral Functions

Differential and integral calculations can only be performed in the NORMAL mode. It is possible to reuse the same equation over and over again and to recalculate by only changing the values without having to re-enter the equation.

  • Performing a calculation will clear the value in the X memory.
  • You can use both global and local variables in the equation.
  • The answer calculated will be stored in the last answer memory.
  • The answer calculated may include a margin of error, or an error may occur. In such a case, recalculate after changing the minute interval ( dx ) or subinterval (n).
  • Since differential and integral calculations are performed based on the following equations, in certain rare cases correct results may not be obtained, such as when performing special calculations that contain discontinuous points.

Integral calculation (Simpson’s rule):

S=—h{f (a)+4{f (a+h)+f (a+3h)+ +f (a+(N–1)h)}

+2{f (a+2h)+f (a+4h)+ +f (a+(N–2)h)}+f(b)} N=2n h=b – a

N

a≤x≤b

Differential calculation:

f(x+––)–f(x– ––) dx

2 f’(x)= dx

Differential function

The differential function is used as follows.

1. Press b 0 to enter the NORMAL mode.
2. Input a formula with an x variable.
3. Press @ 3 .
4. Input the x value and press e .
5. Input the minute interval ( dx ).
6. Press e to calculate.

2 dx

Page 41 of the Sharp EL-5230 user manual — Integral function
Pagina 41 · klik om te vergroten
Pagina 41
Chapter 3Scientific Calculations
  • To exit the differential function, press j .
  • After getting the answer, press e to return to the display for inputting the x value and the minute interval, and press @ h to recalculate at any point.
Sharp EL-5230 — Delete key diagram (page 41)
Afb. 18 · Delete key

d/dx (x4–0.5x3+6x2) j ; X* m 4 - 0.5 ; X 1 + 6 ; X A @ 3

x = 2 dx = 0.00002 d/dx = ?

x = 3 dx = 0.001 d/dx = ?

* X memory is specified by pressing ; then the 3 key.

Integral function

The Integral function is used as follows.

1. Press b 0 to enter the NORMAL mode.
2. Input a formula with an x variable.
3. Press { .
4. Input the starting value (a) of a range of integral and press e .
5. Input the finishing value (b) of a range of integral and press e .
6. Input the subinterval (n).
7. Press e to calculate.
  • To exit the integral function, press j .
  • After getting the answer, press e to return to the display for inputting a range of integral and subinterval, and press @ h to recalculate at any point.
Page 42 of the Sharp EL-5230 user manual — When performing integral calculations
Pagina 42 · klik om te vergroten
Pagina 42
Chapter 3Scientific Calculations
Sharp EL-5230 — Delete key diagram (page 42)
Afb. 19 · Delete key

n = 10 e e e 10 e ∫dx = ?

When performing integral calculations

Integral calculations require a long calculation time, depending on the integrands and subintervals input. During calculation, ‘calculating!’ will be displayed. To cancel calculation, press j. Note that there will be greater integral errors when there are large fluctuations in the integral values during minute shifting of the integral range and for periodic functions, etc., where positive and negative integral values exist depending on the interval. For the former case, make the integral interval as small as possible. For the latter case, separate the positive and negative values. Following these tips will provide calculations results with greater accuracy and will also shorten the calculation time.

Sharp EL-5230 — When performing integral calculations diagram (page 42)
Afb. 20 · When performing integral calculations
Sharp EL-5230 — When performing integral calculations diagram (page 42)
Afb. 21 · When performing integral calculations
Page 43 of the Sharp EL-5230 user manual — Random integer
Pagina 43 · klik om te vergroten
Pagina 43
Chapter 3Scientific Calculations

Random Function

The Random function has four settings for the NORMAL, STAT or PROG mode. (This function is not available while using the N-base function, solver function and simulation calculations.)

Random numbers

A pseudo-random number, with three significant digits from 0 up to 0.999, can be generated by pressing @ w 0 e. To generate further random numbers in succession, press e. Press j to exit.

  • The calculator can regenerate the same random number. (See page 36.)

Random dice

To simulate a die-rolling, a random integer between 1 and 6 can be gener- ated by pressing @ w 1 e. To generate further random numbers in succession, press e. Press j to exit.

Random coin

To simulate a coin flip, 0 (head) or 1 (tail) can be randomly generated by pressing @ w 2 e. To generate further random numbers in succession, press e. Press j to exit.

Random integer

An integer between 0 and 99 can be generated randomly by pressing @ w 3 e. To generate further random numbers in succession, press e. Press j to exit.

Sharp EL-5230 — Random integer diagram (page 43)
Afb. 22 · Random integer

j @ w 0 k 10 e Pick a random number between 0 and 9.99.

  • The result may not be the same each time this operation is performed.
Page 44 of the Sharp EL-5230 user manual — Chain Calculations
Pagina 44 · klik om te vergroten
Pagina 44
Chapter 3Scientific Calculations

Angular Unit Conversions

The angular unit is changed in sequence each time @ ] ( . key) is pressed.

Example Key operations Result

90°→ [rad] j 90 @ ] 1.570796327 → [g] @ ] 100. → [°] @ ] 90.

sin–10.8 = [°] @ w 0.8 e 53.13010235 → [rad] @ ] 0.927295218 → [g] @ ] 59.03344706 → [°] @ ] 53.13010235

Chain Calculations

The previous calculation result can be used in a subsequent calculation. However, it cannot be recalled after entering multiple instructions.

  • When using postfix functions ( , sin, etc.), a chain calculation is possible even if the previous calculation result is cleared by the use of the j key.

Example Key operations Result

6+4=ANS j 6 + 4 e 10. ANS+5 + 5 e 15.

8×2=ANS 8 k 2 e 16. ANS2 A e 256.

44+37=ANS 44 + 37 e 81.

ANS= @ * e 9.

Page 45 of the Sharp EL-5230 user manual — 4 A
Pagina 45 · klik om te vergroten
Pagina 45
Chapter 3Scientific Calculations

Fraction Calculations

Arithmetic operations and memory calculations can be performed using fractions, and conversions between decimal numbers and fractions.

  • If the number of digits to be displayed is greater than 10, the number is converted to and displayed as a decimal number.

Example Key operations Result

1 2 4 3 b c

3— + — = [a—] j 3 k 1 k 2 + 4 k 3 e 4ı5ı6 * →[a.xxx] k 4.833333333 →[d/c] @ F 29ı6

10 — = @ Y 2 k 3 e 4.641588834

( — )

7 k 5 m 5 e

—= 1 k 8 m 1 k 3 e

( — )

—— = @ * 64 k 225 e 8ı15

23 ( 2 m 3 ) k 34 ( 3 m 4 ) e 8ı81

1.2 1.2 k 2.3 e 12ı23 2.3

1°2’3” 1 [ 2 [ 3 k 2 e 0∂31∂1.5∂ 2

1×103 1 ` 3 k 2 ` 3 e 1ı2 2×103

A = 7 j 7 x A 7.

4 A

— = 4 k ; A e 4ı7

1.25 + — = [a.xxx] 1.25 + 2 k 5 e 1.65

2 5 b c

→[a—] k 1ı13ı20

* 4ı5ı6 = 4—

Show 6 more labels / short text on this page
5 = 16807ı3125 · 1ı2 · — = · —– = · ——– = · ——– =
Page 46 of the Sharp EL-5230 user manual — Binary, Pental, Octal, Decimal, and Hexadecimal Operations (N-base)
Pagina 46 · klik om te vergroten
Pagina 46
Chapter 3Scientific Calculations

Binary, Pental, Octal, Decimal, and Hexadecimal Operations (N-base)

This calculator can perform conversions between numbers expressed in binary, pental, octal, decimal and hexadecimal systems. It can also perform the four basic arithmetic operations, calculations with parentheses and memory calculations using binary, pental, octal, decimal, and hexadecimal numbers. Furthermore, the calculator can carry out the logical operations AND, OR, NOT, NEG, XOR and XNOR on binary, pental, octal and hexadeci- mal numbers.

Conversion to each system is performed by the following keys:

@ z: Converts to the binary system. ‘?’ appears.

@ r: Converts to the pental system. ‘q’ appears.

@ g: Converts to the octal system. ‘f’ appears.

@ h: Converts to the hexadecimal system. ‘6’ appears.

@ /: Converts to the decimal system. ‘?’, ‘q’, ‘f’ and ‘6’ disappear

from the display.

Conversion is performed on the displayed value when these keys are pressed.

pressing ,, m, A, 1, l, and i key respectively.

In the binary, pental, octal, and hexadecimal systems, fractional parts cannot be entered. When a decimal number having a fractional part is converted into a binary, pental, octal, or hexadecimal number, the fractional part will be truncated. Likewise, when the result of a binary, pental, octal, or hexadecimal calculation includes a fractional part, the fractional part will be truncated. In the binary, pental, octal, and hexadecimal systems, negative numbers are displayed as a complement.

Page 47 of the Sharp EL-5230 user manual — (BIN)
Pagina 47 · klik om te vergroten
Pagina 47
Chapter 3Scientific Calculations

Example Key operations Result

DEC(25)→BIN j @ / 25 @ z 11001.b

HEX(1AC) @ a 1AC →BIN @ z 110101100.b

→PEN @ r 3203.P

→OCT @ g 654.0

→DEC @ / 428.

BIN(1010–100) @ z ( 1010 - 100 ×11 = ) k 11 e 10010.b

BIN(111)→NEG d 111 e 1111111001.b

HEX(1FF)+ @ a 1FF @ g + OCT(512)= 512 e 1511.0

HEX(?) @ a 349.H

2FEC– j x M @ a 2FEC 2C9E=(A) - 2C9E m 34E.H

+)2000– 2000 - 1901=(B) 1901 m 6FF.H

(C) t M A4D.H

1011 AND j @ z 1011 4 101 = (BIN) 101 e 1.b

5A OR C3 = (HEX) @ a 5A p C3 e DB.H

NOT 10110 = @ z n 10110 e 1111101001.b

(BIN)

24 XOR 4 = (OCT) @ g 24 x 4 e 20.0

B3 XNOR @ a B3 C 2D = (HEX) 2D e FFFFFFFF61.H

→DEC @ / –159.

Page 48 of the Sharp EL-5230 user manual — Time, Decimal and Sexagesimal Calculations
Pagina 48 · klik om te vergroten
Pagina 48
Chapter 3Scientific Calculations

Time, Decimal and Sexagesimal Calculations

Conversion between decimal and sexagesimal numbers can be performed, and, while using sexagesimal numbers, also conversion to seconds and minutes notation. The four basic arithmetic operations and memory calcula- tions can be performed using the sexagesimal system. Notation for sexagesimal is as follows:

12∂34∂56.78∂

Example Key operations Result

12°39’18.05” j 12 [ 39 [ 18.05 →[10] @ : 12.65501389

123.678 → [60] 123.678 @123 ∂ 40 ∂ 40.8 ∂

3h30m45s + 3 [ 30 [ 45 + 6 [ 6h45m36s = [60] 45 [ 36 e 10∂16∂21.∂

1234°56’12” + 1234 [ 56 [ 12 + 0°0’34.567” = [60] 0 [ 0 [ 34.567 e 1234∂56∂47.∂

3h45m – 3 [ 45 - 1.69 e 1.69h = [60] @ : 2∂3∂36.∂

sin62°12’24” = [10] v 62 [ 12 [ 24 e 0.884635235

24°→[ ” ] 24 [ I 6 86400.

1500”→[ ’ ] 0 [ 0 [ 1500 I 7 25.

degree second minute

Page 49 of the Sharp EL-5230 user manual — @ E
Pagina 49 · klik om te vergroten
Pagina 49
Chapter 3Scientific Calculations

Coordinate Conversions

Conversions can be performed between rectangular and polar coordinates.

Y

P (x, y )

Y

P (r, θ)

Rectangular coordinate Polar coordinate

  • Before performing a calculation, select the angular unit.
  • The calculation result is automatically stored in memories.
  • Value of r : R memory
  • Value of θ : θ memory
  • Value of x : X memory
  • Value of y : Y memory
  • r and x values are stored in the last answer memory.

Example Key operations Result

j 6 , 4 x = 6 → r =

r= 7.211102551 y = 4 θ = [°] = 33.69006753

14 , 36 r = 14 → x =

x= 11.32623792 θ = 36[°] y = y= 8.228993532

@ E

Show 4 more labels / short text on this page
r · y · θ · @ u
Page 50 of the Sharp EL-5230 user manual — Calculations Using Physical Constants
Pagina 50 · klik om te vergroten
Pagina 50
Chapter 3Scientific Calculations

Calculations Using Physical Constants

Recall a constant by pressing @ c followed by the number of the physical constant designated by a 2-digit number. The recalled constant appears in the display mode selected with the designated number of decimal places. Physical constants can be recalled in the NORMAL mode (when not set to binary, pental, octal, or hexadecimal), STAT mode, PROG mode and EQN mode.

mended values, or the 1995 Edition of the ‘Guide for the Use of the International System of Units (SI)’ released by NIST (National Institute of Standards and Technology), or on ISO specifications.

No. Constant Symbol Unit c, c 0 m s–1

01 Speed of light in vacuum 02 Newtonian constant of gravitation 03 Standard acceleration of gravity 04 Electron mass 05 Proton mass 06 Neutron mass 07 Muon mass 08 Atomic mass unit-kilogram relationship 09 Elementary charge 10 Planck constant 11 Boltzmann constant 12 Magnetic constant 13 Electric constant 14 Classical electron radius 15 Fine-structure constant 16 Bohr radius 17 Rydberg constant 18 Magnetic flux quantum 19 Bohr magneton 20 Electron magnetic moment 21 Nuclear magneton 22 Proton magnetic moment 23 Neutron magnetic moment

G m3 kg–1 s–2

gn m s–2

mn kg mµ kg lu kg e C h J s k J K–1 µ0 N A–2 ε0 F m–1 re m

m R∞ m–1

µB J T–1

µe J T–1

µN J T–1

µp J T–1

µn J T–1

Show 4 more labels / short text on this page
me kg · mp kg · a0 α · Φ0 Wb
Page 51 of the Sharp EL-5230 user manual — Z 0 Ω
Pagina 51 · klik om te vergroten
Pagina 51
Chapter 3Scientific Calculations

No. Constant Symbol Unit

24 Muon magnetic moment 25 Compton wavelength 26 Proton Compton wavelength 27 Stefan-Boltzmann constant 28 Avogadro constant 29 Molar volume of ideal gas (273.15 K, 101.325 kPa) 30 Molar gas constant 31 Faraday constant 32 Von Klitzing constant 33 Electron charge to mass quotient 34 Quantum of circulation 35 Proton gyromagnetic ratio 36 Josephson constant 37 Electron volt 38 Celsius Temperature 39 Astronomical unit 40 Parsec 41 Molar mass of carbon-12 42 Planck constant over 2 pi 43 Hartree energy 44 Conductance quantum 45 Inverse fine-structure constant 46 Proton-electron mass ratio 47 Molar mass constant 48 Neutron Compton wavelength 49 First radiation constant 50 Second radiation constant 51 Characteristic impedance of vacuum 52 Standard atmosphere

µµ J T–1

λc, p m

σ W m–2 K–4

NΑ, L mol–1

Vm m3 mol–1

R J mol–1 K–1

F C mol–1

-e/me C kg–1

h/2me m2 s–1

γp –1 T s –1

KJ Hz V–1

eV J t K AU m pc m M(12C) kg mol–1

h- J s

mp/me

Mu kg mol–1

λc, n m

c1 W m2

c2 m K

Z 0 Ω

Example Key operations Result

V0 = 15.3 m/s t = 10 s

j 15.3 k 10 + 2 @ Z k @ c 03 k 10 A e 1 2 643.3325

V0 t + gt2 = ? m

Show 6 more labels / short text on this page
λc m · RK Ohm · Eh J · 0 G s · α –1 · Pa
Page 52 of the Sharp EL-5230 user manual — Calculations Using Engineering Prefixes
Pagina 52 · klik om te vergroten
Pagina 52
Chapter 3Scientific Calculations

Calculations Using Engineering Prefixes

Calculation can be executed in the NORMAL mode (excluding N-base), STAT mode and PROG mode using the following 12 types of prefixes.

E P T G M k m µ n p f a

(Exa) (Peta) (Tera) (Giga) (Mega) (kilo) (milli) (micro) (nano) (pico) (femto) (atto)

@ j 0 @ j 1 @ j 2 @ j 3 @ j 4 @ j 5 @ j 6 @ j 7 @ j 8 @ j 9 @ j A @ j B

Example Key operations Result

100m × 10k = 100 @ j 6 k 10 @ j 5 e 1000.

Prefix Operation Unit

Page 53 of the Sharp EL-5230 user manual — Modify Function
Pagina 53 · klik om te vergroten
Pagina 53
Chapter 3Scientific Calculations

Modify Function

Calculation results are internally obtained in scientific notation with up to 14 digits for the mantissa. However, since calculation results are displayed in the form designated by the display notation and the number of decimal places indicated, the internal calculation result may differ from that shown in the display. By using the modify function, the internal value is converted to match that of the display, so that the displayed value can be used without change in subsequent operations.

Example Key operations Result

5÷9=ANS j @ J 1 0 1 ANS×9= 5 z 9 e 0.6 [FIX,TAB=1] k 9 e*1 5.0

5 z 9 e @ n 0.6 k 9 e*2 5.4 @ P 0

*1 5.5555555555555×10–1×9 *2 0.6×9

Page 54 of the Sharp EL-5230 user manual — → → e j
Pagina 54 · klik om te vergroten
Pagina 54
Chapter 3Scientific Calculations

Solver Function

This function enables you to find any variable in an equation.

Entering and solving an equation

The solver function is used as follows.

1. Press b 0 to enter the NORMAL mode.
2. Enter both sides of an equation, using ‘=’ and variable names.
3. Press I 5 .
4. Enter the value of the known variables.
5. Move the cursor (display) to the unknown variables.
6. Press @ h .
  • The solver function can find any variable anywhere in an equation. It can even find variables that appear several times in an equation.

NORMAL MODE 0. TŒ=(4π©GM)R_ Equation entering display

  • You can use both global and local variables in your equation. (See page 58.)
  • Using the solver function will cause variables memory to be overwritten with new values.
  • To exit the solver function, press j .

Changing the value of variables and editing an equation

When you are in the solution display, press e to return to the display for entering values of variables, then return to the equation display in the NORMAL mode by pressing j.

R= 1.127251652 R¬ 9. L¬ 9.

NORMAL MODE 0. TŒ=(4π©GM)R_

→ → e j

G=z 1.5

Solution display Use d u to move between variables.

TŒ=(4π©GM)R

Page 55 of the Sharp EL-5230 user manual — A˚B=C˚D
Pagina 55 · klik om te vergroten
Pagina 55
Chapter 3Scientific Calculations

Solving an equation

Example

Try finding the variables in the equation below.

A B C D × × =

1. Press b 0 to select the NORMAL mode.
2. Press ; A k ; B ; = ; C k ; D. • You must enter the whole equation.
Sharp EL-5230 — A B C D × × = diagram (page 55)
Afb. 23
  • 3. Press I 5 .
  • The calculator automatically calls the display for entering variables and displays the variables in alphabetical order.
  • indicates that there are more variables.
  • If a variable already has a value, the calculator displays that value automatically.
  • 4. Press 10 e .
  • Enters a value for known variable A.
  • The cursor moves onto the next variable.
Sharp EL-5230 — A B C D × × = diagram (page 55)
Afb. 24
5. Press 5 e . • Enters a value for known variable B.
  • 6. Press 2.5 e .
  • Enters a value for known variable C.
  • The cursor moves onto the next variable. indicates that this is the last variable.

A˚B=C˚D

D=z 0.

7. Press @ h . • After showing the ‘calculating!’ display, the calculator finds the value for the unknown variable that was indicated by the cursor.
Sharp EL-5230 — A˚B=C˚D diagram (page 55)
Afb. 25

Values of the right-hand side of the equation

Page 56 of the Sharp EL-5230 user manual — - ERROR 02 - CALCULATION
Pagina 56 · klik om te vergroten
Pagina 56
Chapter 3Scientific Calculations
  • The value shown on the display for the unknown variable does not have to be set to 0 to solve the equation.
  • The answer is displayed on the top line and the values of the lefthand and right-hand sides of the equation appear below.
8. Press e . • Returns you to the display for entering variables.
Sharp EL-5230 — Delete key diagram (page 56)
Afb. 26 · Delete key
  • 9. Press d 8 e .
  • Substitutes the value 8 for B.
  • The cursor moves onto the next variable C.
10. Press @ h . • You can find any unknowns in the same equation.

C= 4. R¬ 80. L¬ 80.

Important notes

There are several important points to remember when you use the solver function.

  • To cancel calculation, press j when ‘calculating!’ is displayed.
  • Before entering the equation, the appropriate angular unit must be selected.
  • The calculator uses Newton’s method to solve equations. Due to this, there may be some equations that it fails to solve even though they are in fact solvable. (See page 123.)
  • The calculator stops calculating when the values it has obtained for the left and right sides of the equation become very close. Thus in certain cases the solution it gives may not be the real answer. (See page 122.)
  • In certain cases, the calculator may abort a calculation and display the message shown on the right. (See page 121.)

- ERROR 02 - CALCULATION

Page 57 of the Sharp EL-5230 user manual — → → e j
Pagina 57 · klik om te vergroten
Pagina 57
Chapter 3Scientific Calculations

Simulation Calculation (ALGB)

This function enables you to find different solutions quickly using different sets of values in the same expression.

Entering an expression for simulation calculation

The simulation calculation is used as follows.

1. Press b 0 to enter the NORMAL mode.
2. Enter an expression with at least one variable.
3. Press @ G .
4. Enter the values of the variables. The calculation result will be displayed after entering the value for all used variables.
  • You can use both global and local variables in your equation, but only local variables will be stored if you save the equation. (See page 58.)
  • You need enter only the side of the equation that contains the variables.
  • Performing simulation calculation will cause the variables memories to be overwritten with new values.
  • The answer calculated will be stored in last answer memory.
  • To exit simulation calculation, press j .

Changing a value of variables and editing an expression

When you are in the solution display, press e to return to the display for entering values of variables, then return to the equation display in the NORMAL mode by pressing j.

NORMAL MODE 0. πRŒH_

→ → e j

785.3981634

H=z 5.

Solution display Use d u to move between variables.

πRŒH= · πRŒH

Page 58 of the Sharp EL-5230 user manual — BCsinA©2=
Pagina 58 · klik om te vergroten
Pagina 58
Chapter 3Scientific Calculations

Simulate an equation for different values

Example

Find the area S = bc sin A ÷ 2 when:

1 b = 3, c = 5 and A = 90° (DEG) 2 b = 3, c = 5 and A = 45° (DEG) 3 b = 4, c = 5 and A = 45° (DEG)

S

1. Press b 0 to select the NORMAL mode.

S =

bc sin A ÷ 2

2. Press @ J 0 0 j . • Sets the angular unit to DEG.
3. Press ; B ; C v ; A z 2. • The equation is entered in the normal way.

NORMAL MODE 0. BCsinA©2_

  • 4. Press @ G .
  • The calculator automatically calls the display for entering variables and picks out the variables in alphabetical order.
  • If a variable already has a value, the calculator displays that value automatically.
  • indicates that there are more variables.

BCsinA©2

A=z 0.

5. Press 90 e . • The calculator picks out the next variable.

BCsinA©2

B=z 0.

6. Press 3 e 5. • indicates that this is the last variable.

BCsinA©2

C=5_

7. Press e .

BCsinA©2=

Area of triangle 1 is 7.5 square units.

b c A

Page 59 of the Sharp EL-5230 user manual — BCsinA©2=
Pagina 59 · klik om te vergroten
Pagina 59
Chapter 3Scientific Calculations
8. Press e and then 45 e . • After getting the answer, press e to return to the display for entering variables.
Sharp EL-5230 — Delete key diagram (page 59)
Afb. 27 · Delete key
9. Press @ h . • Sides b and c are both the same length in triangle 2 as in triangle 1 , so you do not have to re-enter these values.

Area of triangle 2 is displayed.

10. Press e and then d 4 e @ h .

BCsinA©2=

7.071067812

Area of triangle 3 is displayed.

Page 60 of the Sharp EL-5230 user manual — Note:
Pagina 60 · klik om te vergroten
Pagina 60
Chapter 3Scientific Calculations

Filing Equations

When the calculator is in the NORMAL mode (excluding N-base), you can save equations in the EQUATION FILE. Saved equations can be loaded or deleted in the NORMAL mode.

Press f in the NORMAL mode to call the EQUATION FILE menu.

  • Press 0 , 1 or 2 to select if an equation is to be loaded, saved or deleted, respectively.

<EQTN FILE> ƒLOAD ⁄SAVE ¤DEL

Saving an equation

You can save an equation as follows.

1. After entering an equation in the NORMAL mode, press 1 in the EQUATION FILE menu.

SAVE:TITLE?

  • The file name display appears asking you to enter a title.
  • The calculator automatically locks ALPHA on to enable you to enter alphabetic characters easily. To cancel the ALPHA setting, press ; .
2. Enter the title of the file (up to seven characters).

SAVE:RING_

  • If you change your mind and no longer want to save the equation, press j .

“RING” is entered as the file name.

3. Press e to save the equation.
  • The display returns to the display before pressing f .

Note:

  • When saving an equation, local variables (including their values) used in the equation are saved at the same time.
Page 61 of the Sharp EL-5230 user manual — Note:
Pagina 61 · klik om te vergroten
Pagina 61
Chapter 3Scientific Calculations

Loading and deleting an equation

The procedures to retrieve (load) and delete an equation from memory are the same, except that you have to confirm that you wish to delete the equation.

Retrieve or delete an equation as follows.

1. Press f and then 0 or 2 to retrieve (load) or delete.

DEL ¬º⁄RING º¤AREA-3 º‹CIRCUIT

DEL has been selected.

2. Use d u to select the name of the file you wish to retrieve (or delete),and press e .

TITLE:RING DELETE¬[DEL] QUIT¬[ENTER]

  • The display asks for confirmation if you are deleting an equation. Press y to proceed with deletion or e to cancel the operation.

Note:

  • If the equation being retrieved contains local variables, the local variable names and their values will be retrieved along with the equation.
  • Any other equation on the display and local variables before the equation was retrieved are cleared.
Page 62 of the Sharp EL-5230 user manual — Delete key
Pagina 62 · klik om te vergroten
Pagina 62
Page 62 of the Sharp EL-5230 user manual — Delete key
Page 63 of the Sharp EL-5230 user manual — Chapter 4: Statistical Calculations
Pagina 63 · klik om te vergroten
Pagina 63

Chapter 4: Statistical Calculations

The STAT mode is used to perform statistical calculations. Press b 1 to select the statistics mode. The seven statistical calculations listed below can be performed. After selecting the statistics mode, select the desired sub-mode by pressing the number key that corresponds to your choice.

To change statistical sub-mode, reselect statistics mode (press b 1), then select the required sub-mode.

0 (SD)Single-variable statistics
1 (LINE)Linear regression calculation
2 (QUAD)Quadratic regression calculation
3 (EXP)Exponential regression calculation
4 (LOG)Logarithmic regression calculation
5 (POWER)Power regression calculation
6 (INV)Inverse regression calculation
Page 64 of the Sharp EL-5230 user manual — Exponential regression, logarithmic regression, power regression, and inverse regression calculation
Pagina 64 · klik om te vergroten
Pagina 64
Chapter 4Statistical Calculations

The following statistics can be obtained for each statistical calculation (refer to the table below):

Variables Contents Key operations

n Number of samples

¯x Mean of samples (x data)

sx Sample standard deviation (x data)

Q

Population standard deviation (x data) x σ

Sum of samples (x data) x Σ

x2 Sum of squares of samples (x data) Σ

¯y Mean of samples (y data)

sy Sample standard deviation (y data)

Population standard deviation ( y data) σ

Σ

y Sum of samples ( y data)

W

Σ

y 2 Sum of squares of samples (y data)

I 0 A

xy Sum of products of samples (x, y) Σ

I 0 B

a Coefficient of regression equation

b Coefficient of regression equation

c Coefficient of quadratic regression equation

  • Use I key to perform a STAT variable calculation.

Single-variable statistical calculation

Statistics of 1 and value of the normal probability function

Linear regression calculation

Statistics of 1 and 2 (except coefficients c) and, in addition, estimate of y for a given x (estimate y´) and estimate of x for a given y (estimate x´)

Exponential regression, logarithmic regression, power regression, and inverse regression calculation

Statistics of 1 and 2 (except coefficients c). In addition, estimate of y for a given x (estimate y´) and estimate of x for a given y (estimate x´). (Since the calculator converts each formula into a linear regression formula before actual calculation takes place, it obtains all statistics, except coefficients a and b, from converted data rather than entered data.)

y · r Correlation coefficient

Page 65 of the Sharp EL-5230 user manual — Data correction
Pagina 65 · klik om te vergroten
Pagina 65
Chapter 4Statistical Calculations

Quadratic regression calculation

Statistics of 1 and 2 and coefficients a, b, c in the quadratic regression formula (y = a + bx + cx2). (For quadratic regression calculations, no correla- tion coefficient (r) can be obtained.)

Data Entry and Correction

All data entered is kept in memory until STAT memory clear (@ P 2 y) is operated or a new STAT sub-mode is selected. Before entering new data, clear the memory contents.

Data entry

Data _ Data , frequency _ (To enter multiples of the same data)

Data x, Data y _ Data x, Data y, frequency _ (To enter multiples of the same data x and y.)

  • Up to 100 data items can be entered. With single-variable data, a data item without frequency assignment is counted as one data item, while an item assigned with frequency is stored as a set of two data items. With twovariable data, a set of data items without a frequency assignment is counted as two data items, while a set of items assigned with frequency is stored as a set of three data items.

Data correction

Correction prior to pressing _ immediately after a data entry:

Delete incorrect data with j, then enter the correct data.

Single-variable data · Two-variable data

Page 66 of the Sharp EL-5230 user manual — Delete key
Pagina 66 · klik om te vergroten
Pagina 66
Chapter 4Statistical Calculations

Correction after pressing _:

Use u d to display the data set previously entered. Press d to display the data set in ascending (oldest first) order. To reverse the display order to descending (latest first), press the u key. Each data set is displayed with ‘X=’, ‘Y=’, or ‘N:’ (N is the sequential number of the data set).

Sharp EL-5230 — Delete key diagram (page 66)
Afb. 28 · Delete key
  • Display and move the cursor to the data item to be modified by using u d , input the correct value, then press _ or e .
  • To delete a data set, display and move the cursor to an item of the data set to delete by using u d , then press @ # . The data set will be deleted.
  • To add a new data set, press j to exit the display of previously entered data and input the values, then press _ .
Sharp EL-5230 — Delete key diagram (page 66)
Afb. 29 · Delete key

30 d d d 45 45 _ X= 45. 45 3 _ ¤ 3. 45 60 d 60 _ X= 60.

Data x Frequency · Data set number · Frequency

Page 67 of the Sharp EL-5230 user manual — Σ
Pagina 67 · klik om te vergroten
Pagina 67
Chapter 4Statistical Calculations

Statistical Calculation Formulas

Type Regression formula Linear y = a + bx Exponential y = a • ebx

  • Logarithmic y = a + b
  • ln x Power y = a
  • x b

Inverse y = a + b —

Quadratic y = a + bx + cx2

In the statistical calculation formulas, an error will occur if:

  • The absolute value of an intermediate result or calculation result is equal to or greater than 1 × 10 100 .
  • The denominator is zero.
  • An attempt is made to take the square root of a negative number.
  • No solution exists for a quadratic regression calculation.

x = x n x = x2 – nx2

sx = x2 – nx2

Σ

Σ

x = x1 + x2 + ··· + xn x2 = x1

Σ

2 + x2 2 + ··· + xn 2

y = y2 – ny2

sy = y2 – ny2

n – 1 y = y n

Σ

Σ Σ

Σ Σ Σ

xy = x1y1 + x2y2 + ··· + xnyn y = y1 + y2 + ··· + yn

y2 = y1

2 + y2 2 + ··· + yn 2

Show 5 more labels / short text on this page
σ Σ Σ · n · n – 1 · σ · n
Page 68 of the Sharp EL-5230 user manual — Normal Probability Calculations
Pagina 68 · klik om te vergroten
Pagina 68
Chapter 4Statistical Calculations

Normal Probability Calculations

  • P(t), Q(t), and R(t) will always take positive values, even when t<0, because these functions follow the same principle used when solving for an area.
  • Values for P(t), Q(t), and R(t) are given to six decimal places.
Sharp EL-5230 — Normal Probability Calculations diagram (page 68)
Afb. 30 · Normal Probability Calculations

x σ t = Standardization conversion formula

Page 69 of the Sharp EL-5230 user manual — Statistical Calculations Examples
Pagina 69 · klik om te vergroten
Pagina 69
Chapter 4Statistical Calculations

Statistical Calculations Examples

Sharp EL-5230 — Statistical Calculations Examples diagram (page 69)
Afb. 31 · Statistical Calculations Examples

DATA SET= 1. DATA SET= 2. DATA SET= 3. DATA SET= 4.

= I 0 3 e n = I 0 0 e = I 0 4 e = I 0 5 e sx = I 0 2 e sx2 = A e

(95––x) ×10+50= ( 95 - I 0 1 ) sx z I 0 2 k 10 + 50 e

x = 60 → I 1 1 60 I 1 0 ) e

t = –0.5 I 1 3 S 0.5 ) e

Page 70 of the Sharp EL-5230 user manual — Delete key
Pagina 70 · klik om te vergroten
Pagina 70
Chapter 4Statistical Calculations

Example Result Key operations

Sharp EL-5230 — Delete key diagram (page 70)
Afb. 32 · Delete key

DATA SET= 1. DATA SET= 2. DATA SET= 3. DATA SET= 4.

21 40 21 , 40 , 3 _ 21 40

I 2 1 e I 2 3 e I 0 2 e I 0 7 e

x=3 →y'=? 3 I 2 5 y=46 →x' =? 46 I 2 4

x y 12 41 8 13 5 2 23 200 15 71

12 , 41 _ 8 , 13 _ 5 , 2 _ 23 , 200 _ 15 , 71 _

DATA SET= 1. DATA SET= 2. DATA SET= 3. DATA SET= 4. DATA SET= 5.

I 2 0 e I 2 1 e I 2 2 e

x=10 →y'=? 10 I 2 5

y=22 →x'=? 22 I 2 4

Page 71 of the Sharp EL-5230 user manual — Example 1
Pagina 71 · klik om te vergroten
Pagina 71

Chapter 5 Equation Solvers

Simultaneous Linear Equations

Simultaneous linear equations with two unknowns (2-VLE) or with three unknowns (3-VLE) may be solved using this function.

1 2-VLEb 3 0

a1x + b1y = c1 a2x + b2y = c2

a1 b1 a2 b2 D =

2 3-VLEb 3 1

a1x + b1y + c1z = d1 a2x + b2y + c2z = d2 a3x + b3y + c3z = d3

a1 b1 c1 a2 b2 c2 a3 b3 c3

D =

  • If the determinant D = 0, an error occurs.
  • If the absolute value of an intermediate result or calculation result is equal to or greater than 1 × 10 100 , an error occurs.
  • The results obtained by this function may include a margin of error.

Example 1

2x+3y = 4 x = ?

5x+6y = 7 Ò y = ?

1. Press b 3 0 to select 2VLE of the EQN mode.

a⁄z 0. b⁄ 0. c⁄ 0.

  • 2. Enter the value of each coefficient (a1, etc.) 2 e 3 e 4 e 5 e 6 e 7
  • Coefficients can be entered using ordinary arithmetic operations.
  • To clear the entered coefficients, press j .
  • Press d or u to move line by line. Press @ d or @ u to jump to the last or top line.

det(D) = ?

Page 72 of the Sharp EL-5230 user manual — x= 3.238095238 y=–1.638095238 Z = –7.4
Pagina 72 · klik om te vergroten
Pagina 72
Chapter 5Equation Solvers
3. After inputting the last coefficient, press e to solve the 2-VLE. • After solving, press e or j to return to the coefficient entering display. You can use @ h to solve the 2VLE, regardless of the cursor position.

x= –1. y= 2. D= –3.

Example 2

x+y-z = 9 x = ?

6x+6y-z = 17 Ò y = ?

14x-7y+2z = 42 z = ?

1. Press b 3 1 to select 3VLE of the EQN mode.

a⁄z 0. b⁄ 0. c⁄ 0.

  • 2. Enter the value of each coefficient (a1, etc.) 1 e 1 e S 1 e 9 e 6 e 6 e S 1 e 17 e 14 e S 7 e 2 e 42
  • Coefficients can be entered using ordinary arithmetic operations.
  • To clear the entered coefficients, press j .
  • Press d or u to move line by line. Press @ d or @ u to jump to the last or top line.
  • 3. After inputting the last coefficient, press e to solve the 3-VLE.
  • Press d to display the det(D).
  • After solving, press e or j to return to the coefficient entering display. You can use @ h to solve the 3VLE, regardless of the cursor position.

x= 3.238095238 y=–1.638095238 Z = –7.4

D= 105.

det(D) = ?

Page 73 of the Sharp EL-5230 user manual — X⁄ 5. X¤–6.333333333
Pagina 73 · klik om te vergroten
Pagina 73
Chapter 5Equation Solvers

Quadratic and Cubic Equation Solvers

Quadratic (ax2 + bx + c = 0) or cubic (ax3 + bx2 + cx + d = 0) equations may be solved using these functions.

1 Quadratic equation solver (QUAD)b 3 2 2 Cubic equation solver (CUBIC): b 3 3
  • If there are more than 2 results, the next solution can be displayed.
  • The results obtained by this function may include a margin of error.

Example 1

3x2 + 4x – 95 = 0 → x = ?

1. Press b 3 2 to select QUAD of the EQN mode.

a=z 0. b= 0. c= 0.

  • 2. Enter the value of each coefficient (a, etc.) 3 e 4 e S 95
  • Coefficients can be entered using ordinary arithmetic operations.
  • To clear the entered coefficients, press j .
  • Press d or u to move line by line.

3 After inputting the last coefficient, press e to solve the quadratic equation. • After solving, press e or j to return to the coefficient entering display. You can use @ h to solve the quadratic equation, regardless of the cursor position.

X⁄ 5. X¤–6.333333333

Page 74 of the Sharp EL-5230 user manual — X⁄–1.233600307 X¤ 0.216800153 +1.043018296i -
Pagina 74 · klik om te vergroten
Pagina 74
Chapter 5Equation Solvers

Example 2

5x3 + 4x2 +3x + 7 = 0 → x = ?

1. Press b 3 3 to select CUBIC of the EQN mode.

a=z 0. b= 0. c= 0.

  • 2. Enter the value of each coefficient (a, etc.) 5 e 4 e 3 e 7
  • Coefficients can be entered using ordinary arithmetic operations.
  • To clear the entered coefficients, press j .
  • Press d or u to move line by line. Press @ d or @ u to jump to the last or top line.
3. After inputting the last coefficient, press e to solve the cubic equation. • After solving, press e or j to return to the coefficient entering display. You can use @ h to solve the cubic equation, regardless of the cursor position.

X⁄–1.233600307 X¤ 0.216800153 +1.043018296i -

Page 75 of the Sharp EL-5230 user manual — Complex Number Entry
Pagina 75 · klik om te vergroten
Pagina 75

Chapter 6 Complex Number Calculations

The CPLX mode is used to carry out addition, subtraction, multiplication, and division of complex numbers. Press b 4 to select the CPLX mode.

Results of complex number calculations are expressed in two modes:

1 @ E: Rectangular coordinates mode (xy appears.) 2 @ u: Polar coordinates mode (rθ appears.)

Complex Number Entry

1 Rectangular coordinates are entered as follows: x-coordinate + y-coordinate Q

or x-coordinate + Q y-coordinate

2 Polar coordinates are entered as follows: r R θ

r: absolute value θ:argument

  • On selecting another mode, the imaginary part of any complex number stored in the M memory will be cleared.
  • A complex number expressed in rectangular coordinates with the y-value equal to zero, or expressed in polar coordinates with the angle equal to zero, is treated as a real number.
  • Press I 0 to return the complex conjugate of the specified complex number.
Page 76 of the Sharp EL-5230 user manual — 0. COMPLEX MODE
Pagina 76 · klik om te vergroten
Pagina 76
Chapter 6Complex Number Calculations

Example Key operations Result

0. COMPLEX MODE

( 12 - 6 Q ) + ( 7 + 15 Q ) -

(12–6i) + (7+15i) – (11+4i) =

( 11 + 4 Q ) e 8.

+5.i

6×(7–9i)× 6 k ( 7 - 9 Q ) (–5+8i) = k ( S 5 + 8 Q

+606.i

16×(sin30°+ 16 k ( v 30 + icos30°)÷(sin60°+ icos60°)=

Q $ 30 ) z (

Q $ 60 ) e v 60 +

13.85640646 +8.i

@ u 8 R 70 + 12 R 25 e 18.5408873

42.76427608

r1 = 8, θ1 = 70° r2 = 12, θ2 = 25°

↓ r = ?, θ = ?°

(1 + i) @ E 1 + Q e 1. +1.i ↓

@ u 1.414213562 r = ?, θ = ?°

@ E ( 2 - 3 Q (2 – 3i)2 =

) A e –5. –12.i

1 ( 1 + Q ) @ Z e 0.5 1 + i =

conj(5+2i) = I 0 ( 5 + 2 Q ) e 5. –2.i

Show 4 more labels / short text on this page
b 4 · ) e · ∠ · ∠
Page 77 of the Sharp EL-5230 user manual — Note:
Pagina 77 · klik om te vergroten
Pagina 77

Chapter 7 Programming

PROG mode

A program enables you to automate a series of calculations, including those simple and complex. Programs are created either in the NORMAL program mode or in the NBASE program mode.

Entering the PROG mode

1. Press b 2 to select the PROG (PROGRAM) mode.

PROGRAM MODE ƒRUN ⁄NEW ¤EDIT ‹DEL

2. Press 0 to RUN a program, press 1 to create a NEW program, press 2 to EDIT a program, and press 3 to DELETE a program.

Selecting the NORMAL program mode or the NBASE program mode

Before creating a new program (b 2 1), select either the NORMAL program mode or the NBASE program mode.

In the NORMAL program mode, you can perform simple mathematical calculations and statistical operations. In the NBASE program mode, you can perform logical operations and calculations using N-base numbers.

Programming concept

It is not within the scope of this manual to describe how to write programs for the calculator in detail. Previous programming experience is required to read this section. The programming language for this calculator is similar to those in general use today.

All conventional computer and calculator programs use fundamental elements such as input, flow control, loops, calculation, and output. The programming language in your calculator includes commands that allow you to incorporate all of these fundamental elements into your programs. For the command list, refer to the ‘Programming Commands.’ (See page 79.)

Note:

  • Commands must be entered using the COMMAND menu ( i ). DO NOT type commands manually using the ; key.
Page 78 of the Sharp EL-5230 user manual — SLOPE :NORMAL PROGRAM?
Pagina 78 · klik om te vergroten
Pagina 78
Chapter 7Programming

Keys and display

In the PROG mode, to make programs as simple as possible, some keys and the display may work in a different manner to other modes. The differences are described below.

  • Press i (the f key) to directly access the command menu for programming. The Filing Equation function does not work in PROG mode.
  • While entering a program name, keys are locked in ALPHA mode (ALOCK) automatically.
  • In a program, a single line can hold up to 159 letters, where all commands are counted as a single letter. As you type in a line, the text will scroll to the left. Lines do not wrap in the PROG mode.

Creating a NEW Program

After you name the program, the calculator automatically stores the whole program under this name as you create it. You do not have to save the program manually.

Creating a NEW program

1. Press b 2 to enter the PROG mode and then press 1 to create a NEW program.
Sharp EL-5230 — Creating a NEW program diagram (page 78)
Afb. 33 · Creating a NEW program
  • The display prompts you to select the NORMAL program mode or the NBASE program mode.
2. For this example, press 0 to select the NORMAL program mode.
  • The display prompts you to enter a program name.
3. Type the name of the program (i.e., SLOPE).
  • A program name can have up to 7 letters.
  • The calculator automatically switches to the alphabet-lock mode. You do not have to press the ; key each time before entering an alphabetic character.
4. After completion, press e .

SLOPE :NORMAL PROGRAM?

  • You are now ready to write a program.
  • Each program line is saved after you press u , d or e .
  • You can use the calculator’s regular functions as commands. You can also use the additional programming commands in the i menu.
Page 79 of the Sharp EL-5230 user manual — Example
Pagina 79 · klik om te vergroten
Pagina 79
Chapter 7Programming

Use of variables

Global and local variables are treated differently in the PROG mode.

  • The letters A – Z and θ , used on their own, represent global variables. Global variables correspond to the memories of the calculator (e.g., ‘C’ in a program means memory C of the calculator). Global variables allow your programs to use values stored in memories, or to pass variables from one program to another. Global variables also allow you to store results from programs and use them in any mode.
  • You can also name and use up to nine local variables ( @ v ). Local variables retain values only in an individual program.

If a line in your program contains an equation such as Y = M1X + 5, it sets the global variable Y equal to (M1 × X) + 5. On encountering this equation while running the program, if the value of the local variable M1 has not been defined earlier in the program, the calculator prompts you with the display ‘M1=?’ to enter a value for M1. The global variable X will already be set to the value last stored in that memory.

SLOPE :NORMAL Y=M¡X+5 _

SLOPE :NORMAL M¡=?

With just a little practice you will soon become proficient at typing programs into your calculator.

Example

Create a simple program that requests input of the base length (B1) and height (H1) of a triangle and then calculates the area (A). After creating, RUN the program to determine the area of a triangle with a base of 4 units and a height of 3 units.

1. Preparing to create a NEW program
Sharp EL-5230 — Example diagram (page 79)
Afb. 34 · Example
Page 80 of the Sharp EL-5230 user manual — RUN ¬º⁄AREA
Pagina 80 · klik om te vergroten
Pagina 80
Chapter 7Programming
2. Entering the program

Program code Key operations

Print“B≥=BASE i 1 @ v B1 e e @

a = BASE ; e

i 1 @ v d H1 e e @ a = HEIGHT ; e

; A ; = 1 k 2 @ v

e @ v d e e

Print“AREA i 1 @ a AREA ; e

i 0 ; A e Print A

  • To enter more than one alphabetic character, press @ a to apply the alphabet-lock mode. Press ; to escape from this mode.
3. Running the program

Return to the initial display for the PROG mode.

RUN ¬º⁄AREA

Select and RUN the program.

0 (Select the program.)

Enter 4 for B1

AREA A= 6.

Enter 3 for H1

  • If the value of a local variable you defined using @ v is unknown, the program automatically prompts you to input a value.
  • To quit running the program, press j . To run the program again, press e .
  • When a program is running, text displayed by the program (using the Print” command) will wrap to the next line if the text length exceeds the display width.
  • You can only enter one command per line except for special cases such as the ‘If…Goto’ structure.
  • For more programming examples, see Chapter 8: Application Examples.
Show 8 more labels / short text on this page
Print“H≥=HEIGHT · A=1ı2B≥H≥ · Procedure · Key operations Display · j · e · 4 e · 3 e
Page 81 of the Sharp EL-5230 user manual — <COMMAND-1> ƒPrint ⁄Print" ¤Input ‹Wait
Pagina 81 · klik om te vergroten
Pagina 81
Chapter 7Programming

Programming Commands

In this section, all commands that are available in the PROG mode are described, excluding keyboard commands and I menu commands.

Input and display commands

1. While creating a NEW or EDIT program, press i to access the COMMAND menu.

<COMMAND-1> ƒPrint ⁄Print" ¤Input ‹Wait

  • The first page of the COMMAND menu is displayed.
  • Press d or u to scroll page by page.
  • You may directly enter a command by pressing the corresponding alphanumeric key without first having to display the relevant COMMAND menu page.

Command Description Key operations Examples

Displays the value of the specified variable. The display format is determined by the SET UP menu.

Sharp EL-5230 — <COMMAND-1> ƒPrint ⁄Print" ¤Input ‹Wait diagram (page 81)
Afb. 35 · <COMMAND-1> ƒPrint ⁄Print" ¤Input ‹Wait

Displays the text entered after the quotation mark. If the text exceeds three lines, only the last three lines will be displayed.

Temporarily stops the program and prompts you to enter a value for the variable with the display ‘=?’.

Pauses the program for the specified number of seconds. The maximum wait time is 255 seconds. If no wait time is specified, the program pauses until you press any of the keys. The BUSY indicator stays on while the program is waiting.

Print · Print A · Print B≥

Page 82 of the Sharp EL-5230 user manual — Delete key
Pagina 82 · klik om te vergroten
Pagina 82
Chapter 7Programming

Command Description Key operations Examples

Indicates the line is a remark and not a command, thus allowing you to insert comments in the program. Any line beginning with Rem is ignored when running a program. Excessive use of this command will use up a considerable amount of memory.

Terminates the program. If the program finishes at the last command, an End command is not required. If there is no End command in the program, the last calculated answer will be displayed when the program finishes. You can use more than one End command in the same program to terminate after different branches, subroutines, etc. have been executed.

Show 4 more labels / short text on this page
Rem TIME TABLE · Rem <text> · End · End
Page 83 of the Sharp EL-5230 user manual — Flow control
Pagina 83 · klik om te vergroten
Pagina 83
Chapter 7Programming

Flow control

Command Description Key operations Examples

Indicates a destination point for the flow statements Goto and Gosub. Up to seven letters can be used for the label name. Each label name must be unique. You cannot use the same label name more than once in a program. Up to 20 different labels can be used in each program.

Clear the text displayed on the screen.

The If clause must be followed by a conditional statement and then a Goto command. Goto is the only command allowed to be used after the If clause. You can enter ; s before the Goto command to make the line easier to read.

If B≥=1 Goto LOOP1

Causes the program to jump to the stated Label (specified by a Label command). A Goto statement must have a corresponding Label statement line that indicates where to go.

Runs the subroutine beginning at the stated Label (specified by a Label command). A Gosub statement must have a corresponding subroutine that starts after the Label statement and ends with a Return command. Subroutines can be nested up to ten levels deep.

Defines the end of a subroutine. Operation returns to the command following the corresponding Gosub statement.

Show 15 more labels / short text on this page
Label LOOP1 · Label <label name> · Label LOOP2 · Clrt · Clrt · If <condition> · Goto <label name> · Goto <label name> · Goto LOOP2 · Gosub PART1 · Gosub <label name> · i A · Return · i B · Return
Page 84 of the Sharp EL-5230 user manual — A=A+1
Pagina 84 · klik om te vergroten
Pagina 84
Chapter 7Programming

Equalities and inequalities

These expressions are used to form the conditional statement in the If clause. They are the basis for looping and other flow control operation in programs.

The ‘=’ (equals) sign is also used as a function to form a substitution command for variables.

You can also enter ‘=’ by simply pressing ; =.

Description Key operations Examples

i C If B=0 Goto ZERO =

Equals. This function is also used to form a substitution command that assigns a new value to a variable, including incrementing or decrementing.

A=A+1

If B

If B≥

If B>=0 Goto RECALC i F Greater than or equal to. >=

If B≥>0 Goto PSTV i G Greater than >

If A ≠ B Goto DIF i H Not equal to. ≠

Symbols

Page 85 of the Sharp EL-5230 user manual — Statistical Commands
Pagina 85 · klik om te vergroten
Pagina 85
Chapter 7Programming

Statistical Commands

In the PROG mode, statistical commands are only available when the NORMAL program mode is selected. If the NBASE program mode is selected, the statistical command menu cannot be called.

  • When you use the STAT x or STAT xy commands, the calculator erases all data previously stored in the STAT function.

Command Description Key operations Examples

i I STATx Selects single-variable statistics mode (SD). STATx

i J STATxy Selects linear regression calculation mode (LINE). STATxy

Data

Enters new statistical data. The data format must be consistent with the statistics mode selected (single- variable or linear regression). A statistical data set entered in the PROG mode cannot be accessed later for use with STAT functions.

Data

Data

Data

Show 5 more labels / short text on this page
i K · Data 5 · Data 25,2 · Data 72,175 · Data 9,96,3
Page 86 of the Sharp EL-5230 user manual — Editing a Program
Pagina 86 · klik om te vergroten
Pagina 86
Chapter 7Programming

Editing a Program

1. Press b 2 to enter the PROG mode and then press 2 to select the EDIT mode.
2. Select the program you wish to edit and press e .
  • If you want to add text into your program, press @ O .
  • If you want to add lines into your program, press @ O (the shape of the cursor will become a triangle) and then move the cursor to the beginning of the line and press e to add a new line there.
  • Remember that you can enter only one command per line except in the special case of the ‘If…Goto’ command. Do not try to enter two or more commands on a single line.
  • The line you modify is saved after you press u , d or e . If you do not wish to change the line, press j twice. (The line will disappear at this point, however, the contents of the line are not deleted.)
  • To clear an entire line of a program, press j then u , d or e . To delete a blank line, move the cursor to the blank line and press y .
  • Any blank lines will be ignored when running.
  • y deletes the character you have just entered (the character at the cursor position).
  • You can change the name of a program by overwriting the existing name. Press u to move the cursor to the title line and type the new name and press e .
3. Press j to exit the EDIT mode.
Page 87 of the Sharp EL-5230 user manual — BREAK!
Pagina 87 · klik om te vergroten
Pagina 87
Chapter 7Programming

Error Messages

The calculator displays an error message if a program encounters a problem. The error message indicates the nature of the problem while the calculator can display the line where the problem has occurred.

After entering a program, it is often necessary to debug it. To make this task easier, the calculator displays an error message if it encounters a problem while running your program.

For example, if you have more than one label with the same name in your program, you will see the message on the right.

- ERROR 04 - LBL DUPLICATE

To display the faulty line in the EDIT mode, press r or l. To return to the program menu, press j.

You can press j to stop your program at any time while it is running. This will be necessary if your program enters an endless loop.

BREAK!

After ‘BREAK!’ is temporarily displayed, the initial PROG mode display will reappear. For a list of error messages, refer to the Appendix. (See page 120.)

Page 88 of the Sharp EL-5230 user manual — PROGRAM MODE ƒRUN ⁄NEW ¤EDIT ‹DEL
Pagina 88 · klik om te vergroten
Pagina 88
Chapter 7Programming

Deleting Programs

You can create as many programs as you want within the limitations of the calculator’s memory. To free up space for new programs, you must delete old ones.

1. Press b 2 to enter the PROG mode.

PROGRAM MODE ƒRUN ⁄NEW ¤EDIT ‹DEL

2. Press 3 .
Sharp EL-5230 — PROGRAM MODE ƒRUN ⁄NEW ¤EDIT ‹DEL diagram (page 88)
Afb. 36 · PROGRAM MODE ƒRUN ⁄NEW ¤EDIT ‹DEL
  • The delete window appears. All the stored programs are listed.
3. Move the cursor to the program you wish to delete and press e .
  • The calculator asks you if you are sure you want to delete the program.
  • Press y to delete the program or e to cancel this operation.
Page 89 of the Sharp EL-5230 user manual — Some like it hot (Celsius-Fahrenheit conversion)
Pagina 89 · klik om te vergroten
Pagina 89

Chapter 8 Application Examples

Programming Examples

The following examples demonstrate the basic use of programming commands including print, input and flow controls. Use the examples for your programming reference.

Some like it hot (Celsius-Fahrenheit conversion)

This is a program to convert temperatures from Celsius to Fahrenheit and vice versa.

Sharp EL-5230 — Some like it hot (Celsius-Fahrenheit conversion) diagram (page 89)
Afb. 37 · Some like it hot (Celsius-Fahrenheit conversion)
1. Press b 2 1 0 to open a window for creating a NEW program.
2. Type TEMP for the program title then press e .
  • A NEW program called ‘TEMP’ will be created.
3. Enter the program as follows.
  • See ‘ * ’ below for further explanation.
Sharp EL-5230 — Some like it hot (Celsius-Fahrenheit conversion) diagram (page 89)
Afb. 38 · Some like it hot (Celsius-Fahrenheit conversion)

Label START i 6 @ a START ; e

Print”(1) C TO F i 1 ( 1 ) @ a s C s TO s F ; e

Print”(2) F TO C i 1 ( 2 ) @ a s F s TO s C ; e

* Here, the program prompts you to choose which type of conversion you wish to perform. Press 1 for “C TO F” and 2 for “F TO C”.

Page 90 of the Sharp EL-5230 user manual — PROGRAM MODE ƒRUN ⁄NEW ¤EDIT ‹DEL
Pagina 90 · klik om te vergroten
Pagina 90
Chapter 8Application Examples
Sharp EL-5230 — Delete key diagram (page 90)
Afb. 39 · Delete key

If T=1 Goto CTOF i 8 ; T ; = 1 ; s i 9 @ a CTOF ; e

If T=2 Goto FTOC i 8 ; T ; = 2 ; s i 9 @ a FTOC ; e

Goto START i 9 @ a START ; e

Label CTOF i 6 @ a CTOF ; e

F=(9©5)C≠+32 ; F ; = ( 9 z 5 ) @ v C0 e e + 32 e

* The program automatically prompts you to enter a value for the local variable C0.

Label FTOC i 6 @ a FTOC ; e

C=(5©9)˚(F≠-32) ; C ; = ( 5 z 9 ) k ( @ v d F0 e e - 32 ) e

* The program automatically prompts you to enter a value for the local variable F0.

4. Press j to return to the PROG mode menu.

PROGRAM MODE ƒRUN ⁄NEW ¤EDIT ‹DEL

5. Press 0 , select the program ‘TEMP’ and press e .
  • The program prompts you to choose which conversion you wish to perform. Then it asks you to enter the temperature value.

Running the program

Page 91 of the Sharp EL-5230 user manual — T = ————— A + B + C
Pagina 91 · klik om te vergroten
Pagina 91
Chapter 8Application Examples

The Heron Formula

Obtaining the area S of triangle with side lengths of A, B and C using the Heron Formula which is true for any plane triangle.

A B

S

1. Press b 2 1 0 to open a window for creating a NEW program.

S = √ T (T – A) (T – B) (T – C)

2. Type HERON for the program title then press e .

T = A + B + C

  • A NEW program called ‘HERON’ will be created.
3. Enter the program as follows.

Program code Key operations

Label START i 6 @ a START ; e

Print”SIDE LENGTHS i 1 @ a SIDE s LENGTHS ; e

Input A i 2 ; A e

Input B i 2 ; B e

Input C i 2 ; C e

If (A+B)

If (B+C)

If (C+A)

T=(A+B+C)©2 ; T ; = ( ; A + ; B + ; C ) z 2 e

Page 92 of the Sharp EL-5230 user manual — 40 S= 349.944192
Pagina 92 · klik om te vergroten
Pagina 92
Chapter 8Application Examples
Sharp EL-5230 — Delete key diagram (page 92)
Afb. 40 · Delete key

S=‰(T(T-A)(T-B)(T-C)) ; S ; = @ * ( ; T ( ; T - ; A ) ( ; T - ; B ) ( ; T - ; C ) ) e

Label ERROR i 6 @ a ERROR ; e

Print”NO TRIANGLE i 1 @ a NO s TRIANGLE ; e

Goto START i 9 @ a START ; e

Obtain the area of the triangle with the side lengths of 20 cm (A), 35 cm (B) and 40 cm (C). 4. Press j to return to the PROG mode menu.

5. Press 0 , select the program ‘HERON’ and press e .

HERON :NORMAL SIDE LENGTHS A=?

  • If the values you enter do not satisfy the conditions to make a triangle (e.g. A + B > C where A, B, C are the side lengths), the program prompts you to reenter the values from the beginning. If you wish to stop the program, press j .
6. Enter 20 for A, 35 for B and 40 for C.

The area of the triangle is approximately 350 cm2.

40 S= 349.944192

Example · Result

Page 93 of the Sharp EL-5230 user manual — NBASE :NBASE PROGRAM?
Pagina 93 · klik om te vergroten
Pagina 93
Chapter 8Application Examples

2B or not 2B (N-base conversion)

The conversion functions and logical operations can be used in the NBASE program mode. The following is a simple program that converts a decimal number to binary, pental, octal and hexadecimal formats.

1. Press b 2 1 1 to open a window for creating a NEW program in the NBASE program mode.

NBASE :NBASE PROGRAM?

2. Type NBASE for the title then press e .
  • A NEW program called ‘NBASE’ will be created.
3. Enter the program as follows.
Sharp EL-5230 — NBASE :NBASE PROGRAM? diagram (page 93)
Afb. 41

Print”ENTER A i 1 @ a ENTER s A ; e

Print”DECIMAL NUMBER i 1 @ a DECIMAL s NUMBER ; e

Page 94 of the Sharp EL-5230 user manual — Delete key
Pagina 94 · klik om te vergroten
Pagina 94
Chapter 8Application Examples

Program code Key operations

Y¬OCT ; Y @ g e

Print”OCTAL i 1 @ a OCTAL ; e

Print Y i 0 ; Y e

Wait i 3 e

Y¬HEX ; Y @ h e

Print”HEXADECIMAL i 1 @ a HEXADECIMAL ; e

Print Y i 0 ; Y e

4. Press j to return to the PROG mode menu.
5. Press 0 , select the program ‘NBASE’ and press e .
  • The program prompts you to enter a decimal number and then displays it in binary format.
  • Press any key to display the number in pental format, then press any key to see it in octal format, and again press any key to see it in hexadecimal format.
  • Be careful when using the Wait command in NBASE program mode. Numbers followed by Wait are processed according to the current number base, binary, pental, octal, decimal or hexadecimal. To specify the wait time in decimal format, define a variable (e.g., T = 5) for the wait time beforehand and use it in the Wait command (i.e., Wait T).

Running the program

Page 95 of the Sharp EL-5230 user manual — T test
Pagina 95 · klik om te vergroten
Pagina 95
Chapter 8Application Examples

T test

The T-test value is obtained by comparing the mean values of sample data and expected average from sample data. Using the t- distribution table, the reliability of a mean value can be evaluated.

m = expected mean value estimated by sample data n = the number of samples x = actual mean value of the samples sx = standard deviation of the samples

A’s SHOP sells cookies by package on which it is stated contents are 100 g. Buy 6 sample packages and check if the statement is true.

  • Setting an expected mean value as 100 (m = 100 g), a t-test value is obtained. If it is larger than the expected t-value obtained from a tdistribution table (at 5% of risk rate), the estimation is wrong. (In this case, A’s SHOP does not sell honestly.)

Sample 1 2 3 4 5 6

grams 102 95 107 93 110 98

1. Press b 2 1 0 to open a window for creating a NEW program.
2. Type TTEST for the title then press e .
  • A NEW program called ‘TTEST’ will be created.
3. Enter the program as follows.
Show 5 more labels / short text on this page
t = ——— · x – m · sx2 · n —— · Example
Page 96 of the Sharp EL-5230 user manual — T= 0.303058133
Pagina 96 · klik om te vergroten
Pagina 96
Chapter 8Application Examples

Program code Key operations

STATx i I e

Data 102 i K 102 e

Data 95 i K 95 e

Data 107 i K 107 e

Data 93 i K 93 e

Data 110 i K 110 e

Data 98 i K 98 e

Print”MEAN i 1 @ a MEAN ; e

Input M i 2 ; M e

T=(˛-M)©‰(sxŒ©˜) ; T ; = ( I 5 1 - ; M ) z @ * ( I 5 2 A z I 5 0 ) e

Print T i 0 ; T e

End i 5 e

4. Press j to return to the PROG mode menu.
5. Press 0 , select the program ‘TTEST’ and press e .
6. Enter the expected mean value ‘100’ and press e .

T= 0.303058133

The t-test value of 0.303 is smaller than the 2.571, expected mean value obtained from a t-test distribution table (at 5% of risk rate), showing that they sell honestly.

Running the program · Result

Page 97 of the Sharp EL-5230 user manual — S ( X 3 , Y 3 )
Pagina 97 · klik om te vergroten
Pagina 97
Chapter 8Application Examples

A circle that passes through 3 points

When three different points, P (X1, Y1), Q (X2, Y2), S (X3, Y3) are given, obtain the center coordinates O (X, Y) and the radius R of the circle that passes through these points.

To satisfy the above conditions, the distances between P, Q, S and O should be equal. as they are the radius of the same circle. Therefore,

Q ( X 2 , Y 2 )

P ( X 1 , Y 1 )

R

O (X, Y) X1–X Y1–Y R

PO = QO = SO = R

R

Using the Pythagorean theorem,

PO2 = (X1 – X)2 + (Y1 – Y)2 = R2

S ( X 3 , Y 3 )

QO2 = (X2 – X)2 + (Y2 – Y)2 = R2

SO2 = (X3 – X)2 + (Y3 – Y)2 = R2

2{(X1–X2)(Y2–Y3) – (X2–X3)(Y1–Y2)} X = 1

(X12+Y12-X22-Y22)(Y2–Y3) – (X22+Y22-X32-Y32)(Y1–Y2)

(X12+Y12-X22-Y22)(X2–X3) – (X22+Y22-X32-Y32)(X1–X2)

2{(Y1–Y2)(X2–X3) – (Y2–Y3)(X1–X2)} Y = 2

R = (X – X1)2 + (Y – Y1)2 3

To enhance both readability and writability of the program, intermediate variables G, H, I, J, K and M are used.

The above equations reduce to

GM – HK 2 (IM – JK) X = GJ – HI 2 (KJ – MI) Y =

1. Press b 2 1 0 to open a window for creating a NEW program.
2. Type CIRCLE for the title then press e .
  • A NEW program called ‘CIRCLE’ will be created.
3. Enter the program as follows.

Program code Key operations

Print”ENTER COORDS i 1 @ a ENTER s COORDS ; e

G=X≥Œ+Y≥Œ-X√Œ-Y√Œ ; G ; = @ v X1 e e A + @ v d Y1 e e A - @ v d d X2 e e A - @ v d d d Y2 e e A e

* Calculate intermediate values.

then

Page 98 of the Sharp EL-5230 user manual — Delete key
Pagina 98 · klik om te vergroten
Pagina 98
Chapter 8Application Examples

Program code Key operations

H=X√Œ+Y√Œ-X…Œ-Y…Œ ; H ; = @ v 2 A + @ v 3 A - @ v d X3 e e A - @ v d Y3 e e A e

I=X≥-X√ ; I ; = @ v 0 - @ v 2 e

J=X√-X… ; J ; = @ v 2 - @ v 4 e

K=Y≥-Y√ ; K ; = @ v 1 - @ v 3 e

M=Y√-Y… ; M ; = @ v 3 - @ v 5 e

X=(GM-HK)©2(IM-JK) ; X ; = ( ; G ; M - ; H ; K ) z 2 ( ; I ; M - ; J ; K ) e

* Perform equation 1.

Print X i 0 ; X e

Wait i 3 e

Y=(GJ-HI)©2(KJ-MI) ; Y ; = ( ; G ; J - ; H ; I ) z 2 ( ; K ; J - ; M ; I ) e

* Perform equation 2.

Print Y i 0 ; Y e

Wait i 3 e

R=‰((X-X≥)Œ+(Y-Y≥)Œ) ; R ; = @ * ( ( ; X - @ v 0 ) A + ( ; Y - @ v 1 ) A ) e

* Perform equation 3.

Print R i 0 ; R e

Obtain the center coordinates (X, Y) and radius R of the circle that passes through points P(1, 9), Q (7, 1) and S (0, 2).

4. Press j to return to the PROG mode menu.
5. Press 0 , select the program ‘CIRCLE’ and press e .
6. Enter the coordinates (X 1 to X 3 , Y 1 to Y 3 ) for the three points.

The center is (4, 5) and radius is 5.

Example · Result

Page 99 of the Sharp EL-5230 user manual — DECAY :NORMAL PROGRAM?
Pagina 99 · klik om te vergroten
Pagina 99
Chapter 8Application Examples

Radioactive decay

Carbon-14 (14C) is a naturally occurring radioactive isotope of carbon used in the carbon dating process. Because carbon-14 decays at a steady rate, it is possible to determine the age of a once living specimen by measuring the residual amount of 14C it contains.

The mass of 14C contained in a sample changes according to the equation

–ln ( ––– )

M1 M0 k

M = M0 e–kt or t =

where M1 = Mass of 14C at time t

M0 = Original mass of 14C

k = Radioactive decay constant (for 14C, k = 1.2118 × 10–4 year–1)

t = Elapsed time in years

This program asks for a original mass and current mass of 14C and tells you how old the specimen is. It then finds the half-life of 14C.

1. Press b 2 1 0 to open a window for creating a NEW program.
2. Type DECAY for the title then press e .

DECAY :NORMAL PROGRAM?

  • A NEW program called ‘DECAY’ will be created.
3. Enter the program as follows.
Sharp EL-5230 — DECAY :NORMAL PROGRAM? diagram (page 99)
Afb. 42

Print”ORIGINAL MASS i 1 @ a ORIGINAL s MASS ; e

Input M≠ i 2 @ v M0 e e e

Print”CURRENT MASS i 1 @ a CURRENT s MASS ; e

Input M≥ i 2 @ v d M1 e e e

Example

Page 100 of the Sharp EL-5230 user manual — DECAY :NORMAL ORIGINAL MASS Mº=?
Pagina 100 · klik om te vergroten
Pagina 100
Chapter 8Application Examples
Sharp EL-5230 — Delete key diagram (page 100)
Afb. 43 · Delete key

1.2118œ-4 ( @ v 1 z @ v 0 ) ) z 1.2118 ` S 4 e

  • The half-life of a radioactive isotope is the time required for half of its mass to decay.
4. Press j to return to the PROG mode menu.
5. Press 0 , select the program ‘DECAY’ and press e . 6. Enter 100 for M 0 and 50 for M 1 .

DECAY :NORMAL ORIGINAL MASS Mº=?

T= 5719.980034 YEARS

The half-life of 14C is 5719.980034 years.

Running the program · Result

Page 101 of the Sharp EL-5230 user manual — Z 2
Pagina 101 · klik om te vergroten
Pagina 101
Chapter 8Application Examples

Delta-Y impedance circuit transformation

Transformation of a Y impedance circuit to an equivalent Delta impedance circuit and vice versa.

The Delta-Y transformation is defined by the following formula:

Z 2

R 1

R 2

R R 2

Z 1

Z 3

Z 1 Z 2

Z 1 = —

R 1 = ———

Z Z 2 Z 3

R 3

R R 3

Z 2 = —

R 2 = ———

Z Z 3 Z 1

Z 3 = —

R R 1

R 3 = ———

Z

where R = R1R2 + R2R3 + R3R1

where Z = Z1 + Z2 + Z3

1. Press b 2 1 0 to open a window for creating a NEW program.
2. Type DELTAY for the title then press e .
  • A NEW program called ‘DELTAY’ will be created.
3. Enter the program as follows.

Program code Key operations

Print”(1)DELTA TO Y i 1 ( 1 ) @ a DELTA s TO s Y ; e

Print”(2)Y TO DELTA i 1 ( 2 ) @ a Y s TO s DELTA ; e

Input X i 2 ; X e

If X=1 Goto DTOY i 8 ; X ; = 1 ; s i 9 @ a DTOY ; e

If X=2 Goto YTOD i 8 ; X ; = 2 ; s i 9 @ a YTOD ; e

Label DTOY i 6 @ a DTOY ; e

Page 102 of the Sharp EL-5230 user manual — Delete key
Pagina 102 · klik om te vergroten
Pagina 102
Chapter 8Application Examples

Program code Key operations

Z=Z≥+Z√+Z… ; Z ; = @ v Z1 e e + @ v d Z2 e e + @ v d d Z3 e e e

R≥=Z≥Z√©Z @ v d d d R1 e e ; = @ v 0 @ v 1 z ; Z e

Print R≥ i 0 @ v 3 e

Wait i 3 e

R√=Z√Z…©Z @ v d R2 e e ; = @ v 1 @ v 2 z ; Z e

Print R√ i 0 @ v 4 e

Wait i 3 e

R…=Z…Z≥©Z @ v d R3 e e ; = @ v 2 @ v 0 z ; Z e

Print R… i 0 @ v 5 e

End i 5 e

Label YTOD i 6 @ a YTOD ; e

R=R≥R√+R√R…+R…R≥ ; R ; = @ v 3 @ v 4 + @ v 4 @ v 5 + @ v 5 @ v 3 e

Z≥=R©R√ @ v 0 ; = ; R z @ v 4 e

Print Z≥ i 0 @ v 0 e

Page 103 of the Sharp EL-5230 user manual — (1)DELTA TO Y (2)Y TO DELTA X=?
Pagina 103 · klik om te vergroten
Pagina 103
Chapter 8Application Examples
Sharp EL-5230 — Delete key diagram (page 103)
Afb. 44 · Delete key

Z√=R©R… @ v 1 ; = ; R z @ v 5 e

Z…=R©R≥ @ v 2 ; = ; R z @ v 3 e

When the impedances Z1, Z2, Z3 of a delta impedance circuit are 70, 35, 140 respectively, obtain the impedances R1, R2, R3 of a Y circuit.

4. Press j to return to the PROG mode menu.
5. Press 0 , select the program ‘DELTAY’ and press e .

(1)DELTA TO Y (2)Y TO DELTA X=?

The direction of transformation will be asked.

6. Press 1 e to select ‘DELTA TO Y’ transformation.
7. Enter 70 for Z 1 , 35 for Z 2 and 140 for Z 3 .

The impedances R1, R2, R3 of the targeted Y impedance circuit are 10, 20 and 40, respectively.

Example · Result

Page 104 of the Sharp EL-5230 user manual — A
Pagina 104 · klik om te vergroten
Pagina 104
Chapter 8Application Examples

Obtaining tensions of strings

Suppose a bar is hung from the ceiling by two strings such that it balances with angles the strings make from the perpendicular lines A and B. If the weight of the bar is W, obtain the tensions in the strings S and T.

W sin (A + B) sin B sin (A + B)

—— = —— =

B A

T = W —————

T

sin A sin (A + B)

G

S

S = W —————

where Wweight T, S: tension in strings A, B: angles that strings make

S B

W

W

from perpendicular lines (DMS) Ggravity

A

T

1. Press b 2 1 0 to open a window for creating a NEW program.
2. Type TENSION for the title then press e .
  • A NEW program called ‘TENSION’ will be created.
3. Enter the program as follows.

Program code Key operations

Print“ANGLES i 1 @ a ANGLES ; e

Input A i 2 ; A e

Input B i 2 ; B e

Print”WEIGHT i 1 @ a WEIGHT ; e

Input W i 2 ; W e

C=AΩDEG ; C ; = ; A @ : e

D=BΩDEG ; D ; = ; B @ : e

Show 4 more labels / short text on this page
S sin A · T sin B · Perpendicular · line
Page 105 of the Sharp EL-5230 user manual — 23.761 T= 21.966
Pagina 105 · klik om te vergroten
Pagina 105
Chapter 8Application Examples
Sharp EL-5230 — Delete key diagram (page 105)
Afb. 45 · Delete key

E=sin(C+D) ; E ; = v ( ; C + ; D ) e

S=W ˚ sin C©E @ a S = W ; k v ; C z ; E e

T=W ˚ sin D©E @ a T = W ; k v ; D z ; E e

Calculate the tension in the strings S and T when the weight of the bar is 40 kg, angle A: 30° 15' 20" and angle B: 27° 45' 40".

4. Press j @ J 0 0 to set the angular unit to DEG, then @ J 1 0 3 to set display to fixed mode with the decimal point of 3 .
  • In this program input angles by degree/minute/second format. They will be automatically converted to decimal degrees.
5. Press b 2 0 , select the program ‘TENSION’ and press e .
6. Enter 30 [ 15 [ 20 for angle A and press e .
7. Enter 27 [ 45 [ 40 for angle B and press e .
8. Enter 40 for weight W and press e for S.
9. Press e for T.

Tension in the strings S and T are 23.761 kg and 21.966 kg, respectively.

23.761 T= 21.966

Example · Results

Page 106 of the Sharp EL-5230 user manual — S = (P – D) —————
Pagina 106 · klik om te vergroten
Pagina 106
Chapter 8Application Examples

Purchasing with payment in n-month installments

If you wish to buy goods with the price of P by n-month installments, this program determines the payment per month.

i 1 – (1 + i)–n

S = (P – D)

where S: payment due every month n : n-month installment P: price of the product D: down payment i: installment payment interest rate (%)

1. Press b 2 1 0 to open a window for creating a NEW program.
2. Type PAYBYMN for the title then press e .
  • A NEW program called ‘PAYBYMN’ will be created.
3. Enter the program as follows.

Program code Key operations

Print”PRICE i 1 @ a PRICE ; e

Input P i 2 ; P e

Print”DOWN PAYMENT i 1 @ a DOWN s PAYMENT ; e

Input D i 2 ; D e

Print”MONTHS i 1 @ a MONTHS ; e

Input N i 2 ; N e

Print”RATE i 1 @ a RATE ; e

Input I i 2 ; I e

I=I©100 ; I ; = ; I z 100 e

S=(P-D)˚I©(1-(1+I)^(-N)) ; S ; = ( ; P - ; D ) k ; I z ( 1 - ( 1 + ; I ) m ( S ; N ) ) e

Page 107 of the Sharp EL-5230 user manual — 1 S= 241.1351893
Pagina 107 · klik om te vergroten
Pagina 107
Chapter 8Application Examples

Program code Key operation

Print S i 0 ; S e

If you wish to buy furniture costing $3,000 with $500 as a down payment and pay the remainder in 11 month’s installments with a monthly interest rate of 1%, how much is the monthly payment?

4. Press j to return to the PROG mode menu.
5. Press 0 , select the program ‘PAYBYMN’ and press e .

PAYBYMN:NORMAL PRICE P=?

6. Enter 3000 for P, 500 for D, 11 for N and 1 for I.

Your monthly payment is approx. $241.

1 S= 241.1351893

Example · Result

Page 108 of the Sharp EL-5230 user manual — Digital dice
Pagina 108 · klik om te vergroten
Pagina 108
Chapter 8Application Examples

Digital dice

This program simulates rolling of multiple dice. You can play a dice game without dice or where there is not enough space to roll dice.

At the first stage, ask the number of dice to use for play. Secondly, roll dice and display the result and wait until any key is pressed.

1. Press b 2 1 0 to open a window for creating a NEW program.
2. Type DICE for the title then press e .
  • A NEW program called ‘DICE’ will be created.
3. Enter the program as follows.

Program code Key operations

Print”NO OF DICE i 1 @ a NO s OF s DICE ; e

Input N i 2 ; N e

Label PLAY i 6 @ a PLAY ; e

M=1 ; M ; = 1 e

X=0 ; X ; = 0 e

Label ROLL i 6 @ a ROLL ; e

X=X+r.dice ; X ; = ; X + @ w 1 e

M=M+1 ; M ; = ; M + 1 e

If M

Print X i 0 ; X e

Wait i 3 e

Goto PLAY i 9 @ a PLAY ; e

4. Press j to return to the PROG mode menu.
5. Press 0 , select the program ‘DICE’ and press e .
6. Enter the number of dice to play and press e .
7. Press e (or any other key) to continue to play. Press j to quit.

Running the program

Page 109 of the Sharp EL-5230 user manual — How many digits can you remember?
Pagina 109 · klik om te vergroten
Pagina 109
Chapter 8Application Examples

How many digits can you remember?

The calculator displays randomly created numbers with the number of digits (up to 9) you specified for the number of seconds you entered and asks you to enter the number you remembered. After 10 tries the score is displayed. The larger the number of digits and the shorter the seconds, the higher the score is.

1. Press b 2 1 0 to open a window for creating a NEW program.
2. Type NUMBER for the title then press e .
  • A NEW program called ‘NUMBER’ will be created.
3. Enter the program as follows.

Program code Key operations

M=1 ; M ; = 1 e

A=0 ; A ; = 0 e

Print”HOW MANY DIGITS i 1 @ a HOW s MANY s DIGITS ; e

Label NINE i 6 @ a NINE ; e

Print”LESS THAN 9 DIGITS i 1 @ a LESS s THAN s ; 9 @ a s DIGITS ; e

Input N i 2 ; N e

If N>9 Goto NINE i 8 ; N i G 9 ; s i 9 @ a NINE ; e

Print”HOW LONG i 1 @ a HOW s LONG ; e

Input T i 2 ; T e

Label QUESTION i 6 @ a QUESTION ; e

Label AGAIN i 6 @ a AGAIN ; e

S=ipart(random˚10^3) ; S ; = I 1 ( @ w 0 k @ Y 3 ) e

Page 110 of the Sharp EL-5230 user manual — Delete key
Pagina 110 · klik om te vergroten
Pagina 110
Chapter 8Application Examples

Program code Key operations

If S

S=S˚10^(-3) ; S ; = ; S k @ Y ( S 3 ) e

If N>6 Goto SIX i 8 ; N i G 6 ; s i 9 @ a SIX ; e

If N>3 Goto THREE i 8 ; N i G 3 ; s i 9 @ a THREE ; e

Q=ipart(Sx10^N) ; Q ; = I 1 ( ; S k @ Y ; N ) e

Goto DISPLAY i 9 @ a DISPLAY ; e

Label SIX i 6 @ a SIX ; e

; Q ; = I 1 ( ; S k @ Y ( ; N - 6 ) ) k @ Y 6 + @ w 0 k @ Y 6 + @ w 0 k @ Y 3 e

Goto DISPLAY i 9 @ a DISPLAY ; e

Label THREE i 6 @ a THREE ; e

; Q ; = I 1 ( ; S k @ Y ( ; N - 3 ) ) k @ Y 3 + @ w 0 k @ Y 3 e

Label DISPLAY i 6 @ a DISPLAY ; e

Clrt i 7 e

Print Q i 0 ; Q e

Q=ipart(S˚10^(N-6))˚10^6 +random˚10^6+random˚10^3 · Q=ipart(S˚10^(N-3))˚10^3 +random˚10^3

Page 111 of the Sharp EL-5230 user manual — Delete key
Pagina 111 · klik om te vergroten
Pagina 111
Chapter 8Application Examples

Program code Key operations

Wait T i 3 ; T e

Clrt i 7 e

Print”ANSWER i 1 @ a ANSWER ; e

Input X i 2 ; X e

* If answer is correct, add (30 x number of digits / number of seconds) to score.

If X Q Goto WRONG i 8 ; X i H ; Q ; s i 9 @ a WRONG ; e

A=A+int(10˚N©T˚3) ; A ; = ; A + I 2 ( 10 k ; N z ; T k 3 ) e

Label WRONG i 6 @ a WRONG ; e

M=M+1 ; M ; = ; M + 1 e

If M

Print”YOUR SCORE IS i 1 @ a YOUR s SCORE s IS ; e

Print A i 0 ; A e

End i 5 e

4. Press j to return to the PROG mode menu.
5. Press 0 , select the program ‘NUMBER’ and press e .
6. Enter the number of digits you wish to play with N.
7. Enter the number of seconds to display the numbers.
8. Immediately after you press e , the game will start.
9. After ‘ANSWER X=?’ is displayed, enter the number you remembered and press e . After 10 tries, the score is displayed.

Running the program

Page 112 of the Sharp EL-5230 user manual — TŒ=(4πŒ)©(GM)˚ R„ G=z 0.000
Pagina 112 · klik om te vergroten
Pagina 112
Chapter 8Application Examples

Calculation Examples

Geosynchronous orbits

The orbit of a satellite about the Earth is geosynchronous if the period of the orbit matches the period of the Earth’s rotation. At what distance from the center of the Earth can geosynchronous orbit occur?

The period of an orbit is described by the equation

T 2 = ——

GM

where T = period of orbit

G = Gravitational constant (6.6742 × 10–11 m3 kg–1s–2) M = Mass of the Earth (5.976 × 1024 kg) r = Distance between the satellite and the center of the Earth (radius of orbit)

The Earth rotates once every 23 hours, 56 minutes and 4.09 seconds. At first, convert this time into seconds.

1. Press b 0 23 [ 56 [ 4.09 [ I 6 .

23∂56∂4.09∂Ωse c 86164.09

  • Determining the value of T.
2. Press x T to store the result as global variable T.
3. Press @ J 1 1 4 .

86164.09 AnsÒT 8.616

  • Select the scientific display format with four significant digits.
  • Use the solver function to solve the equation for r.
4. Press j ; T A ; = ( 4 @ s A ) z ( ; G ; M ) k ; R 1 .

0.000 TŒ=(4πŒ)©(GM)˚ R„ _

5. Check the equation on the display and press I 5 to enter the solver function.

TŒ=(4πŒ)©(GM)˚ R„ G=z 0.000

4π2 · r3

Page 113 of the Sharp EL-5230 user manual — L 2 L 1
Pagina 113 · klik om te vergroten
Pagina 113
Chapter 8Application Examples
6. Press @ c 02 e 5.976 ` 24 e .

TŒ=(4πŒ)©(GM)˚ R„ R=z 0.000

  • Use the physical constants function for the G value.
  • After completion of entering values for variables G and M, the cursor moves on to variable R. (The variable T has already its value.)
7. Press @ h .

Geosynchronous orbit is possible approxi- mately 42,170 km (4.217 × 107 meters) from the center of the Earth.

R= 4.217 R¬ 7.424 L¬ 7.424

Twinkle, twinkle, little star (Apparent magnitude of stars)

The apparent magnitude of a star is a measure of how bright it appears. It is a function of how far away the star is and the luminosity of the star.

Sharp EL-5230 — Twinkle, twinkle, little star (Apparent magnitude of stars) diagram (page 113)
Afb. 46 · Twinkle, twinkle, little star (Apparent magnitude of…

Since stars are seen from different distances, their luminosities must be standardized before they can be compared. This is done using a quantity called the absolute magnitude, which is a measure of how bright that star would appear if it was viewed from a distance of 10 parsecs (about 32.6 light years).

If the absolute magnitude of two stars is known, the ratio of their luminosities is given by the equation.

L 2 L 1

Log —— = 0.4 (M1 – M2)

where M1 = Absolute magnitude of the first star

M2 = Absolute magnitude of the second star L1 = Luminosity of the first star L2 = Luminosity of the second star

Result

Page 114 of the Sharp EL-5230 user manual — 4.8-(log0.0003 ©0.4)= 13.60719686
Pagina 114 · klik om te vergroten
Pagina 114
Chapter 8Application Examples

What is the ratio of the sun’s luminosity to that of a star having an absolute magnitude of 2.89? (The sun’s absolute magnitude is 4.8.)

The former equation is equivalent to

L 2 L 1

—— = 10 0.4 (M1 – M2)

whereM2 = 2.89

1. Press b 0 and @ P 0 .
2. Press @ Y ( 0.4 k ( 4.8 - 2.89 ) ) e .

1 Î ^(0.4˚(4.8-2. 89))= 5.807644175

5.807644175 The star is nearly six times as luminous as the sun.

A second star has only 0.0003 times the luminosity of the sun. What is its absolute magnitude?

The previous equation is equivalent to

L 2 L 1

M 2 = M 1 – ————

L 2 L 1

where —— = 0.0003

1. Press 4.8 - ( l 0.0003 z 0.4 ) e .

The absolute magnitude of the second star is approximately 13.6.

4.8-(log0.0003 ©0.4)= 13.60719686

Show 5 more labels / short text on this page
Example 1 · Result · Example 2 · log —— · Result
Page 115 of the Sharp EL-5230 user manual — Memory calculations
Pagina 115 · klik om te vergroten
Pagina 115
Chapter 8Application Examples

Memory calculations

When you want to use the calculator for tasks such as adding up total sales, you can perform this type of operation using single-variable statistics.

In one week, an electrical store sold the items listed below at the prices and in the quantities shown. What was the total sales figure?

Sharp EL-5230 — Memory calculations diagram (page 115)
Afb. 47 · Memory calculations
1. Press b 1 0 to select the single-variable statistics mode.
2. Press 599.95 , 10 _ , 159.95 , 27 _ , 39.95 , 52 _ and 7.95 , 108 _ .
Sharp EL-5230 — Memory calculations diagram (page 115)
Afb. 48 · Memory calculations
  • All the data is entered.
3. Press I 0 4 e .
  • The calculator displays Σ x , that is the total sales value.
  • Total sales were $13254.15.

Example · Result

Page 116 of the Sharp EL-5230 user manual — 35 P 5 :
Pagina 116 · klik om te vergroten
Pagina 116
Chapter 8Application Examples

The state lottery

The state you live in has two different numbers lotteries. In the first, you must pick 6 numbers between 1 and 50 in any order. In the second, you have to pick 5 numbers between 1 and 35, but you must pick them in the correct order. Which lottery gives you the better chance of winning?

In the first lottery, your chances of winning with one ticket are one in 50C6:

1. Press b 0 50 @ N 6 e .
0. 50Ç6= 15890700.

Your chances of winning the second lottery with one ticket are one in

35 P 5 :

2. Press 35 @ e 5 e .

15890700. 35∏5= 38955840.

  • Your chances are better in the first lottery.

Example · Result

Page 117 of the Sharp EL-5230 user manual — When to replace the batteries
Pagina 117 · klik om te vergroten
Pagina 117

Appendix

Battery Replacement

Batteries used

  • Use only the specified batteries.

Lithium battery CR2032 2

  • Be sure to write down any important data stored in the memory before replacing the batteries.

Notes on battery replacement

Improper handling of batteries can cause electrolyte leakage or explosion. Be sure to observe the following handling rules:

  • Do not mix new and old batteries.
  • Make sure the new batteries are the correct type.
  • When installing, orient each battery correctly as indicated in the calculator.
  • Batteries are factory-installed before shipment, so may become exhausted before reaching the service life stated in the specifications.

When to replace the batteries

Replace the batteries immediately when any of the following situations occur:

  • The calculator does not turn on when j is pressed.
  • The message ‘Change Batteries’ appears.
  • Continued use of the calculator when in low battery status may result in the memory contents being cleared.
  • Executing programs under low battery condition may result in the memory contents being cleared.
  • Failure to follow the battery replacement procedure as described may result in the memory contents being cleared.

Type Model Quantity

Page 118 of the Sharp EL-5230 user manual — Replacement procedure
Pagina 118 · klik om te vergroten
Pagina 118

Cautions

  • Fluid from a leaking battery accidentally entering an eye could result in serious injury. Should this occur, wash with clean water and immediately consult a doctor.
  • Should fluid from a leaking battery come in contact with your skin or clothes, immediately wash with clean water.
  • If the product is not to be used for some time, to avoid damage to the unit from leaking batteries, remove them and store in a safe place.
  • Do not leave exhausted batteries inside the product.
  • Do not fit partially used batteries, and be sure not to mix batteries of different types.
  • Keep batteries out of the reach of the children.
  • Exhausted batteries left in the calculator may leak and damage the calculator.
  • Explosion risk may be caused by incorrect handling.
  • Do not throw batteries into a fire as they may explode.

Replacement procedure

  • All memory contents will be cleared if you remove both batteries at the same time. Always replace each battery before removing the other one.
  • Make sure the power is turned off before replacing the batteries.
  • Do not press j until the battery replacement procedure is complete.
1. Turn the power off by pressing @ o .
2. Remove the two screws.
3. Lift the battery cover to remove.

Appendix

Page 119 of the Sharp EL-5230 user manual — Automatic power off function
Pagina 119 · klik om te vergroten
Pagina 119
4. Remove one used battery by prying it out with a ball-point pen or similar pointed object.
  • Replace one battery at this step.
Sharp EL-5230 — Delete key diagram (page 119)
Afb. 49 · Delete key
5. Install a new battery with the positive side (+) facing up.
Sharp EL-5230 — Delete key diagram (page 119)
Afb. 50 · Delete key
6. Repeat steps 4 and 5 to replace the other battery.
7. Replace the cover and screws.
8. Press the RESET switch using the tip of a ball-point pen or similar object.

zALL DATA CL?z z YES¬[DEL] z z NO¬[ENTER]z

  • If you cannot see the message on the right, repeat steps 1–7.
Sharp EL-5230 — zALL DATA CL?z z YES¬[DEL] z z NO¬[ENTER]z diagram (page 119)
Afb. 51 · zALL DATA CL?z z YES¬[DEL] z z NO¬[ENTER]z
9. Press e .
  • Do not press y . If y is pressed, the memory contents will be cleared.
10. Adjust the LCD contrast. (See page 118.)

Automatic power off function

The calculator will turn itself off to save battery power if no key is pressed for approximately 10 minutes.

Appendix

Page 120 of the Sharp EL-5230 user manual — 624BYTES FREE EQTN: 15 PROG: 09
Pagina 120 · klik om te vergroten
Pagina 120

The OPTION menu

The OPTION menu controls display contrast, memory checking and deletion of data.

The OPTION display

Press @ o (S key) to show the OPTION menu.

<OPTION> ƒCTRST ⁄M.CHK ¤DELETE

  • Press j to return to the mode in which you were working previously.

Contrast

Press 0 in the OPTION menu to show the LCD CONTRAST display.

LCD CONTRAST [+] [-] DARK® ¬LIGHT

  • Press + to darken the display and - to lighten it.
  • It is possible to lighten the display so much that the calculator appears to be off. If the display remains blank when you press X , press @ o 0 and then press + repeatedly to darken the display.

Memory check

Press 1 in the OPTION menu to show the MEMORY CHECK display.

624BYTES FREE EQTN: 15 PROG: 09

  • The amount of free memory in bytes is shown on the first line. When the calculator is used for the first time, the following amount of memory is available.
  • The figures after EQTN are the numbers of equations (Filing equations functions) in the NORMAL mode.
  • The figures after PROG are the numbers of programs stored in the PROG mode.

For a detailed description of how memory is used, refer to ‘Memory usage’. (See page 126.)

Appendix · [EL-5250] 4,096 bytes · [EL-5230] 1,280 bytes

Page 121 of the Sharp EL-5230 user manual — If an Abnormal Condition Occurs
Pagina 121 · klik om te vergroten
Pagina 121

Deleting equation files and programs

Press 2 in the OPTION menu to show the DELETE menu.

<<DELETE>> ƒEQTN ⁄PROG

  • Press 0 or 1 to delete equation files or programs that have been stored in the NORMAL or PROG modes, respectively.

After selecting the mode for which data is to be deleted, press y to delete data. Press e to cancel the operation.

  • Once a file has been deleted there is no way to recover it.

To delete individual files, enter the mode that contains the data you want to delete and use the specific delete function from the menu. (See pages 59 and 86.)

If an Abnormal Condition Occurs

Should an abnormal condition occur, such as none of the keys (including j) functioning, press the RESET switch located on the back of the calculator. Refer to page 32.

Appendix

Page 122 of the Sharp EL-5230 user manual — DATA OVER
Pagina 122 · klik om te vergroten
Pagina 122

Error Messages

The following table shows common error messages and suggestions for correcting the error.

Error no. Error message Solution

Verify you are using the correct syntax for the function you are trying to apply.

SYNTAX

CALCULATION

Check you have not attempted to divide by zero or made some other calculation error.

NESTING

Use of more than the available number of buffers was attempted. (There are 10 buffers* for numeric values and 24 buffers for calculation instructions.) * 5 buffers in the CPLX mode.

LBL DUPLICATE

Make sure your program does not use the same label name to specify more than one location.

Make sure your program does not have a Goto or Gosub command pointing to a label that does not exist. Note that you can include labels that are not pointed to by Goto or Gosub commands without affecting program operation.

LBL UNDEFINED

LBL OVER

Make sure your program does not have more than 20 labels.

Make sure your program does not have more than 10 levels of nested subroutines.

GOSUB STACK

CAN’T RETURN

Make sure your program does not have a Return command with no corresponding Gosub command.

MEMORY OVER

Not enough free memory remains for what you are trying to do. Delete unneeded files and try again.

Make sure the maximum number of 99 saved equations or 99 programs is not exceeded. Delete unneeded equations or programs and try again.

STORAGE FULL

Use of more than 100 data items in the STAT mode was attempted. The maximum number of 160 characters in the equation input buffer was exceeded.

DATA OVER

BREAK!

You have pressed j to stop a program or solver calculation.

Appendix · (No number)

Page 123 of the Sharp EL-5230 user manual — Range of expected values
Pagina 123 · klik om te vergroten
Pagina 123

Using the Solver Function Effectively

The calculator uses Newton’s method to solve equations. (See page 52.) Because of this, the solution it provides may differ from the true solution, or an error message may be displayed for a soluble equation. This section shows how you can obtain a more acceptable solution or make the equation soluble in such cases.

Newton’s method

Sharp EL-5230 — Newton’s method diagram (page 123)
Afb. 52 · Newton’s method

Newton’s method is a successive approximation technique that uses tangential lines. The calculator chooses an ‘approximate’ solution then calculates and compares the right-hand and left- hand sides of the equation. Based on the result of this comparison, it chooses another ‘approximate’ solution. It repeats this process until there is hardly any discrepancy between the right-hand and left-hand sides of the equation.

Newton’s method Intersections of dotted lines with the x-axis give successive approximate solutions found using Newton’s method.

‘Dead end’ approximations

When @ h is pressed for the first time, the calculator takes the value that is stored in memory, or zero if no value is stored, to be the initial expected value for the unknown variable and tries to solve the equation. If it fails to find an acceptable solution using this expected value, it tries again using up to nine more initial expected values until a solution is found. If none of the values lead by successive approximation toward an acceptable solution — but rather to a ‘dead end’ — the calculator will abort calculation and display an error message.

- ERROR 02 - CALCULATION

Range of expected values

After the stored value (or zero) has been tried, new initial expected values are selected according to the range of expected values for the equation. (See ‘Changing the range of expected values’.) To choose which initial expected values to try, the calculator divides the range into eight subranges of equal width and tries each of the values at the edges of these subranges in turn (starting with the lower limit of the range of expected values, a).

Appendix · y = f(x)

Page 124 of the Sharp EL-5230 user manual — Changing the range of expected values
Pagina 124 · klik om te vergroten
Pagina 124

Calculation accuracy

  • The calculator solves an equation by comparing the values of the lefthand and right-hand sides of the equation through 14-digit internal operations. If the value of the left-hand side is sufficiently close to agreeing with that of the right-hand side the calculator may present one of the ‘approximate’ values as a solution — even though it is not the true solution.
  • The calculator will also stop trying to solve an ‘approximate’ solution either when it has performed more than 50 iterations using each initial expected value or when it has obtained an ‘approximate’ solution that is the same (to 10-digit accuracy) twice in succession.

Changing the range of expected values

After entering your equation by pressing I 5, press @ J to adjust the range of expected values. The calculator will then prompt you for a range of expected values (between –1 × 1099 and +1 × 1099) to be used in the calculation.

Sharp EL-5230 — Changing the range of expected values diagram (page 124)
Afb. 53 · Changing the range of expected values
  • The range of expected values returns to its default setting (–1 × 10 10 to +1 × 10 10 ) when the current equation is cleared or the mode is changed.

After entering the lower and upper limits (a and b) of the range of expected values, press j to return to the previous display.

  • The best solution can be found by defining the lower or upper limit (a or b) or initial value close to the expected solution.
  • Having done this, press @ h several times to generate slightly different solutions. You can judge which of these is the best by comparing the values displayed for the left-hand and right-hand sides of the equation.

Appendix

Page 125 of the Sharp EL-5230 user manual — Equations that are difficult to solve
Pagina 125 · klik om te vergroten
Pagina 125

Equations that are difficult to solve

Newton’s method has problems in solving certain types of equations, either because the tangential lines it uses to approximate the solutions iterate only slowly toward the correct answer, or because they do not iterate there at all. Examples of such equations include equations of which steep slopes are a feature (e.g. y = 10x–5), periodic functions (e.g. y = sin x), functions featuring an inflection (e.g. y = x3–3x2 + x + 5) and functions where the unknown variable appears as a denominator (e.g. y = 8/x + 1).

Solving y =10x – 5 for y = 0. Because of the steep slope, it takes a long time to iterate to the correct solution. Set limits a and b as close as possible either side of your expected solution.

Many of those equations may become soluble if a range of expected values is defined that corresponds closely to the real solution.

  • For periodic functions such as sin x and cos x , the gradient near peaks or troughs is very shallow. If the initial expected value falls too close to a peak or trough, the calculator may iterate to a totally different cycle of the function and will not obtain an accurate solution. Make sure the initial expected value is an appropriate distance between a peak and a trough.

Solving y = sin x for y = 0. If the Initial expected value is too close to a peak, the calculator will iterate away from the correct solution.

  • Where appropriate, you can try rearranging the equation so that the unknown variable is no longer a denominator.

Solving y = x3 – 3x2 + x + 5 for y = 0. If the initial expected value is x = 3, no solution is obtained. However, setting x to –3 gives the correct solution of –1.

Appendix · y · y

Page 126 of the Sharp EL-5230 user manual — Calculation ranges
Pagina 126 · klik om te vergroten
Pagina 126

Technical Data

Calculation ranges

  • Within the ranges specified, the calculator is accurate to ±1 of the least significant digit of the mantissa. However, in continuous calculations the calculation error increases due to the accumulation of each successive calculation error. (This is the same for y x , x , n!, e x , In etc., where continuous calculations are performed internally.)
  • Furthermore, the calculation error will accumulate and become larger in the vicinity of inflection points and singular points of functions, and in programmed repetitive calculations.
  • Calculation ranges

±10-99 to ±9.999999999 × 1099 and 0.

If the absolute value of an entry or a final or intermediate result of a calculation is less than 10-99, the value is considered to be 0 in calculations and on the display.

DEG| x | < 10 10

(tan x: | x | 90 (2n–1))* sin x, cos x, RAD: | x | < —– × 1010

π 180 π 2 10 9

tan x (tan x| x | — (2n–1))*
GRAD| x | < —– × 10 10
(tan x| x | 100 (2n–1))*

sin–1x, cos–1x | x | ≤ 1 tan–1x, 3 x | x | < 10100

In x, log x 10–99 ≤ x < 10100

  • y > 0: –10 100 < x log y < 100
  • y = 0: 0 < x < 10 100

yx • y < 0: x = n (0 < l x l < 1: — = 2n–1, x / = 0)*, –10100 < x log | y | < 100

  • y > 0: –10 100 < — log y < 100 ( x / = 0)
  • y = 0: 0 < x < 10 100 x y
  • y < 0: x = 2n–1 (0 < | x | < 1 : — = n, x / = 0)*,

1 x 1 x

–10100 < — log | y | < 100

Show 8 more labels / short text on this page
Appendix · Function Dynamic range · =/ · =/ · =/ · √ · __ · √
Page 127 of the Sharp EL-5230 user manual — C 2 + D 2
Pagina 127 · klik om te vergroten
Pagina 127

ex –10100 < x ≤ 230.2585092 10x –10100 < x < 100

sinh x, cosh x, | x | ≤ 230.2585092 tanh x sinh–1 x | x | < 1050

cosh–1 x 1 ≤ x < 1050 tanh–1 x | x | < 1 x2 | x | < 1050

x3 | x | < 2.15443469 × 1033

x 0 ≤ x < 10100

x–1 | x | < 10100 (x ≠ 0) n! 0 ≤ n ≤ 69*

0 ≤ r ≤ n 9999999999*

—— < 10100

0 ≤ r ≤ n 9999999999* 0 ≤ r ≤ 69

—— < 10100

↔DEG, D°M’S 0°0’0.00001” ≤ | x | < 10000°

x, y → r, x2 + y2 < 10100

0 ≤ r < 10100

DEG| θ | < 10 10

r, θ → x, y RAD: | θ | < —– × 1010

GRAD| θ | < — × 10 10

DEG→RAD, GRAD DEG: | x | < 10100 DRG RAD→GRAD: | x | < — × 1098

(A+Bi)+(C+Di | A + C | < 10100, | B + D | < 10100

(A+Bi)–(C+Di | ) ) A – C | < 10100, | B – D | < 10100

(A+Bi) (C+Di) (AC – BD) < 10100

(AD + BC) < 10 100

AC + BD < 10 100

C 2 + D 2

(A+Bi)÷(C+Di) BC – AD < 10100

C 2 + D 2

C 2 + D 2 / = 0

Show 16 more labels / short text on this page
Appendix · Function Dynamic range · __ · √ · ≤ · nPr · n! (n-r)! · ≤ · nCr · n! (n-r)! · θ · π · 180 10 9 · → · π · ×
Page 128 of the Sharp EL-5230 user manual — Memory usage
Pagina 128 · klik om te vergroten
Pagina 128

→DEC DEC : | x | ≤ 9999999999 →BIN BIN : 1000000000 ≤ x ≤ 1111111111 →PEN 0 ≤ x ≤ 111111111 →OCT PEN : 2222222223 ≤ x ≤ 4444444444 →HEX 0 ≤ x ≤ 2222222222 AND OCT : 4000000000 ≤ x ≤ 7777777777 OR 0 ≤ x ≤ 3777777777 XOR HEX : FDABF41C01 ≤ x ≤ FFFFFFFFFF XNOR 0 ≤ x ≤ 2540BE3FF

BIN1000000000 ≤ x ≤ 1111111111

0 ≤ x ≤ 111111111 PEN : 2222222223 ≤ x ≤ 4444444444

NOT 0 ≤ x ≤ 2222222221 OCT : 4000000000 ≤ x ≤ 7777777777

0 ≤ x ≤ 3777777777 HEX : FDABF41C01 ≤ x ≤ FFFFFFFFFF

0 ≤ x ≤ 2540BE3FE BIN : 1000000001 ≤ x ≤ 1111111111

0 ≤ x ≤ 111111111 PEN : 2222222223 ≤ x ≤ 4444444444

NEG 0 ≤ x ≤ 2222222222 OCT : 4000000001 ≤ x ≤ 7777777777

0 ≤ x ≤ 3777777777 HEX : FDABF41C01 ≤ x ≤ FFFFFFFFFF

0 ≤ x ≤ 2540BE3FF

* n, rinteger

Memory usage

The amounts of memory the calculator uses for variables, programs and equations are shown below.

Each variable uses 1 byte, and each local variable uses 9 bytes to store its value.

Creating a new program uses 32 bytes of memory irrespective of the length of its name.

Each line in a program uses 3 bytes plus the number of characters or commands on the line (each character or command uses 1 byte). For example, the two lines of the program shown below use 60 bytes.

Show 4 more labels / short text on this page
Appendix · Function Dynamic range · Variables · Programs
Page 129 of the Sharp EL-5230 user manual — AND
Pagina 129 · klik om te vergroten
Pagina 129

Program title If A=0 Goto ABC A¡=A+1

32 bytes 3 bytes 3 bytes

32 bytes 11 bytes 17 bytes

8 bytes 5 bytes 9 bytes

Total consumption 38 bytes 13 bytes 9 bytes 60 bytes

Filing Equation functions Each stored equation uses 30 bytes plus the number of characters or commands.

Priority levels in calculations

Operations are performed according to the following priority:

Fractions (1ı4, etc.)

∠ , engineering prefixes

Functions preceded by their argument (x−1, x2, n!, etc.)

Yx, x

Implied multiplication of a memory value (2Y, etc.)

Functions followed by their argument (sin, cos, (–), etc.)

Implied multiplication of a function (2sin30, etc.)

AND

OR, XOR, XNOR

=, M+, M−, ⇒M, DEG, RAD, GRAD, DATA, CD, →rθ, →xy, and other calculation ending instructions

  • If parentheses are used, the parenthesized calculations have precedence over the other calculations.
Show 10 more labels / short text on this page
Appendix · Characters, commands and · For value · Management · of local variables · Total · variables · nCr, nPr · ×, ÷ · +, −
Page 130 of the Sharp EL-5230 user manual — Specifications
Pagina 130 · klik om te vergroten
Pagina 130

Specifications

ModelEL-5230/5250
Display type[14 characters and 2 exponents] × 3 rows
Dot matrix characters5 × 7 dots /character
Number of display digits10-digit mantissa + 2-digit exponent
Input ranges±10 -99 to ±9.999999999 × 10 99 and 0. (up to 10-digit mantissa)
Number of internal calculation digits14-digit mantissa
Pending operations24 calculations 10 numeric values (5 numeric values in the CPLX modes)

Calculation functions: Calculations (four basic arithmetic operations, calculations with parentheses, memory calculations, function calculations, etc.), differential/integral functions, binary/ pental/octal/decimal/hexadecimal operations, solver functions, simulation calculations, complex number calculations, etc.

Statistical calculations: One-variable statistics, two-variable statistics, normal probability calculations, etc.

Equation solvers: Simultaneous linear equations, and quadratic/cubic equation solvers.

Programming function: New programming, running a program, and editing a program and deleting a program.

Option menuLCD contrast, memory check and data deletion
Memory capacity[EL-5250] 4,096 bytes (user area)

[EL-5230] 1,280 bytes (user area)

Power source3 V (DC): Lithium battery (CR 2032) × 2
Auto power offAfter approximately 10 minutes
Power consumption0.002 W
Operating temperature0°C – 40°C (32°F – 104°F)

Operating time: Approximately 1,800 hours* (at 25°C (77°F), assuming each hour consists of 5 minutes of continuous operation and 55 minutes of display time).

Appendix

Page 131 of the Sharp EL-5230 user manual — For More Information about Scientific Calculators
Pagina 131 · klik om te vergroten
Pagina 131

Dimensions: 79.6 mm (W) × 154.5 mm (D) × 15.2 mm (H) 3-1/8” (W) × 6-3/32” (D) × 19/32” (H)

WeightApprox. 97 g (0.22 lb) (including batteries, but not including hard case)
Accessories2 lithium batteries (installed), operation manual, quick reference card and hard case

* This value may vary according to the way the calculator is used and other factors.

For More Information about Scientific Calculators

Visit our Web site.

http://sharp-world.com/calculator/

In Europe:

This equipment complies with the requirements of Directive 89/336/EEC as amended by 93/ 68/EEC.

Dieses Gerät entspricht den Anforderungen der EG-Richtlinie 89/336/EWG mit Änderung 93/ 68/EWG.

Ce matériel répond aux exigences contenues dans la directive 89/336/CEE modifiée par la directive 93/68/CEE.

Dit apparaat voldoet aan de eisen van de richtlijn 89/336/EEG, gewijzigd door 93/68/EEG.

Dette udstyr overholder kravene i direktiv nr. 89/336/EEC med tillæg nr. 93/68/EEC.

Quest’ apparecchio è conforme ai requisiti della direttiva 89/336/EEC come emendata dalla direttiva 93/68/EEC.

89/336/, 93/68/ .

Este equipamento obedece às exigências da directiva 89/336/CEE na sua versão corrigida pela directiva 93/68/CEE.

Este aparato satisface las exigencias de la Directiva 89/336/CEE modificada por medio de la 93/68/CEE.

Denna utrustning uppfyller kraven enligt riktlinjen 89/336/EEC så som kompletteras av 93/68/ EEC.

Dette produktet oppfyller betingelsene i direktivet 89/336/EEC i endringen 93/68/EEC.

Tämä laite täyttää direktiivin 89/336/EEC vaatimukset, jota on muutettu direktiivillä 93/68/ EEC.

чÌÌÓ ÛÒÚÓÈÒÚ‚Ó ÒÓÓÚ‚ÂÚÒÚ‚ÛÂÚ Ú·ӂ‡ÌËflÏ ‰ËÂÍÚË‚˚ 89/336/EEC Ò Û˜ÂÚÓÏ ÔÓÔ‡‚ÓÍ 93/68/EEC.

Ez a készülék megfelel a 89/336/EGK sz. EK-irányelvben és annak 93/68/EGK sz. módosításában foglalt követelményeknek.

Tento pfiístroj vyhovuje poÏadavkÛm smûrnice 89/336/EEC v platném znûní 93/68/EEC.

Appendix

Page 132 of the Sharp EL-5230 user manual — SHARP CORPORATION
Pagina 132 · klik om te vergroten
Pagina 132

04LGK (TINSE0796EHZZ) PRINTED IN CHINA / IMPRIMÉ EN CHINE / IMPRESO EN CHINA

SHARP CORPORATION

Bronnen

Referenties en links

Pagina's waarnaar wordt verwezen in deze handleiding — fabrikant, ondersteuning en downloads.

Vraag stellen over de Sharp EL-5230

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Sharp EL-5230

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Sharp EL-5230 handleiding-pdf

132 pagina's·4.6 MB·Rekenmachine·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…