Gebruiksaanwijzing /service van het product BS2000/OSD van de fabrikant Siemens
Ga naar pagina of 111
U25339-J-Z126-1-7600 1 1 Intr oduction The range of BS2000/OSD servers has been e xtended b y the addition of the S130 series. The spectrum of user facilities of the ne w models lies between the S110 and H130 ser v er series. The y are powerful systems f or scientific and commercial applications.
2 U25339-J-Z126-1-7600 Summary of contents Introduction 1.2 Summary of contents This operating man ual cov ers the hardware operating functions of the S130 Business Ser ver with the 3970-SKP service/console processor .
U25339-J-Z126-1-7600 3 2 Impor tant instructions This chapter cov ers the most impor tant safety instructions. It also includes some man uf ac- turer instructions and notes on radio interf erence.
4 U25339-J-Z126-1-7600 Manufacturer instructions Important instructions ● The cab les must be laid in such a wa y that there is no danger of any one tripping ov er them and the y cannot be damaged. ● Data transmission lines m ust not be connected or disconnected dur ing electr ical stor ms.
U25339-J-Z126-1-7600 5 3 Overview This chapter provides inf or mation on the configuration le v els and the configuration of the S130 Business Ser ver series and the concept of system operation.
6 U25339-J-Z126-1-7600 Configuration levels of the S130 Business Server Overview If the HVZ (high-a vailability f eature) option S130K-1H is a vailab le, a def ectiv e processor can be replaced with the high-av ailability processor (the high-a vailability f eature is only av ailable f or the models S130-C , S130-E and S130-P).
U25339-J-Z126-1-7600 7 Overview Concept of system operation 3.2 Concept of system operation System operation is described in the chapter “Basics of system operation“ of the “SINIX-2000 V7.0“ [1] manual. The f ollowing section lists the most impor tant hardware and softw are components for S130 operation.
8 U25339-J-Z126-1-7600 Concept of system operation Overview ● The ser vice/console processor (3970-SKP) with the SINIX operating system. Operation of the S130 system tak es place via a local PC: the 3970-SKP ser vice/console processor . S130 and 3970-SKP communicate with one another in three w ays: – ser ial line (V .
U25339-J-Z126-1-7600 9 Overview Concept of system operation 3.2.2 Software The f ollowing softw are components play an impor tant role in S130 operation: ● Window interf ace The SINIX operating system is run on the 3970-SKP . One component of SINIX is the window interf ace based on the X Window system (see the ”SINIX-2000 V7.
10 U25339-J-Z126-1-7600 Concept of system operation Overview 3.2.3 A uthorization contr ol The access to operation of the BS2000, SVP and SINIX system components is protected: ● Access to the BS2000.
U25339-J-Z126-1-7600 11 4 Contr ols and indicator s The f ollowing controls and indicators are pro vided for the S130 Business Server: – control panel on the Business Ser ver cabinet, page 12 – co.
12 U25339-J-Z126-1-7600 Contr ol panel on the Business Ser ver cabinet Controls and indicators 4.1 Contr ol panel on the Business Ser ver cabinet The control panel is connected with the ser vice processor (SVP) in the S130 Business Ser ver .
U25339-J-Z126-1-7600 13 Controls and indicators Control panel on the Business Server cabinet Inf or mation is displa yed on the LCD displa y in the f ollowing f or mat: Meanings: Line Displa y field .
14 U25339-J-Z126-1-7600 Contr ol panel on the Business Ser ver cabinet Controls and indicators PO WER COMPLETE This green light illuminates after the system po wer controller has ter minated the s witching on sequence without errors. The light is e xtinguished when the POWER OFF k ey is pressed.
U25339-J-Z126-1-7600 15 Controls and indicators Control panel on the Business Server cabinet 4.1.2 Button functions LCD B A CK LIGHT The LCD displa y ST A TUS (background) is illuminated f or fiv e minutes when y ou press this b utton. The lights go out immediately when you press this b utton again.
16 U25339-J-Z126-1-7600 Contr ol panel on the global storage cabinet Controls and indicators 4.2 Contr ol panel on the global storage cabinet The control panel is connected to the ser vice processor in global storage.
U25339-J-Z126-1-7600 17 Controls and indicators Control panel on the global storage cabinet The inf or mation is shown on the LCD displa y in the f ollowing f or mat: Meanings: Line Displa y field Di.
18 U25339-J-Z126-1-7600 Contr ol panel on the global storage cabinet Controls and indicators PO WER COMPLETE This green light is lit up after the system po w er controller has terminated the switching on sequence without any errors . The light is e xtinguished when the POWER OFF b utton is pressed.
U25339-J-Z126-1-7600 19 Controls and indicators EMERGENCY STOP switch 4.3 EMERGENCY ST OP switc h Not only the Business Ser ver cabinet, b ut also the global storage and battery cabinets each ha ve an EMERGENCY ST OP switch. If the EMERGENCY ST OP s witch on the S130 is pressed, global storage is also s witched off .
Eine Dokuschab lone v on F rank Flachenec k er b y f .f . 1992.
U25339-J-Z126-1-7600 21 5 Switching the S130 Business Server on and off This chapter describes the various technical options f or switching the S130 Business Ser ver on and off , depending on the hardware.
22 U25339-J-Z126-1-7600 Switching the S130 on and off using the contr ol panel When both systems are ready , i.e. all windo ws on the 3970-SKP hav e been opened and the LCD displa y on the S130 no longer shows an y P codes, y ou can log in on the SVP (see page 34ff) and star t the BS2000 system via PROGRAM LO AD FRAME: DET AIL-1 (see page 51).
U25339-J-Z126-1-7600 23 Switching the S130 on and off from the SKP c) Y ou can also ter minate the SINIX system using the on/off button on the SKP . Ho we v er , please mak e note of the follo wing: I.
24 U25339-J-Z126-1-7600 Switching the S130 on and off fr om the SKP Y ou access the “Switching on / off the host” f or m via the sysadm menu: Ê Select or open a SINIX screen Ê Login: root or sysadm Ê Enter pass word Ê F or login with root: enter sysadm The SINIX system administration windo w is display ed.
U25339-J-Z126-1-7600 25 Switching the S130 on and off from the SKP Ê Select the menu item “host”: Ê Select the menu item “host - The P ow er ON/OFF of the Host”:.
26 U25339-J-Z126-1-7600 Switching the S130 on and off fr om the SKP The “Switching on / off the host” f or m is displa yed: Inf or mation on operation of the FMLI interf aces can be f ound in the “SINIX-2000 V7.
U25339-J-Z126-1-7600 27 Switching the S130 on and off from the SKP The s witching operating is perf or med after you press the ( SAVE ) key . P3.
28 U25339-J-Z126-1-7600 A utomatic switching on/off of the S130 via the SKP 5.3 A utomatic s witching on/off of the S130 via the SKP T o s witch the S130 on and off from the SKP , it must ha v e the optional on/off f acility . The on/off f acility is linked to the SKP via the V .
U25339-J-Z126-1-7600 29 Automatic switching on/off of the S130 via the SKP The “Switching on / off the host” f or m is displa yed:´ By entering YES for the tw o questions at the top of the window.
30 U25339-J-Z126-1-7600 Time-driven switc hing on and off of the SKP and S130 5.4 Time-driven s witching on and off of the SKP and S130 The SKP can s witch itself and the S130 on and off at a cer tain time.
U25339-J-Z126-1-7600 31 Switching the SKP and S130 on and off using ATOP 3914 5.5 Switching the SKP and S130 on and off using A T OP 3914 The S130 can also be s witched on automatically using the SKP in conjunction with the A T OP 3914. The optional on/off facility is required f or this.
32 U25339-J-Z126-1-7600 Switching the S130 on and off fr om a remote system 5.6 Switching the S130 on and off fr om a remote system Switching on and off can be carried out from a remote system using a modem/DCU . Inf or mation on operating the DCU can be f ound in the data sheet “8323 Data Communi- cation Unit“ [5].
U25339-J-Z126-1-7600 33 6 Standar d pr ocessing in SVP mode Jobs are assigned to the ser vice processor via special SVP menus, so-called SVP fr ames. All the inf or mation you require as an oper ator working with SVP frames can be f ound in this chapter .
34 U25339-J-Z126-1-7600 In v oking an SVP frame Standard processing in SVP mode 6.1 In v oking an SVP frame By def ault, an SVP window is configured with the label “SVPST0 #1 (computer name)” to operate the SVP .
U25339-J-Z126-1-7600 35 Standard processing in SVP mode Invoking an SVP frame Figure 8: SVPST0 #1 window Ê Select the “Standard par tner ($KVPHV0)” function by pressing the ke y or “Last connection ($KVPHV0)” b y pressing the ke y . Confir m with the k ey .
36 U25339-J-Z126-1-7600 In v oking an SVP frame Standard processing in SVP mode The pass word entr y window is displa y ed: Figure 9: SVPST0 #1 window (pass word entry) Ê Enter the pass word f or the specified user ID and press .
U25339-J-Z126-1-7600 37 Standard processing in SVP mode General frame structure 6.2 General frame structure Figure 10: General structure of an SVP frame Each SVP frame is divided into diff erent areas: Lines 1 - 21 This is the displa y area of a fr ame .
38 U25339-J-Z126-1-7600 General frame structure Standard processing in SVP mode 6.2.1 System status messages in line 22 Figure 11: F or mat of the status display in line 22 Meaning of the status inf o.
U25339-J-Z126-1-7600 39 Standard processing in SVP mode General frame structure 46 - 55 SYS-DO WN CL-ST OP CHK-ST OP COMP-ST OP ST OP PSW -LOOP W AIT RU N LOAD The system ma y be in the system down state. This displa y can also appear when Write-Console messages are output (e.
40 U25339-J-Z126-1-7600 General frame structure Standard processing in SVP mode 6.2.2 System status messages in line 23 The f ollowing picture sho ws the extended area of the system status messages in.
U25339-J-Z126-1-7600 41 Standard processing in SVP mode General frame structure 6.2.3 Har dware status displa y in line 24 The f ollowing diagr am shows the f or mat of the hardware status displa y in.
42 U25339-J-Z126-1-7600 Using frames Standard processing in SVP mode 6.3 Using frames Y ou assign a job to the SVP by in v oking the rele vant frame , selecting the desired function, and specifying the required parameters .
U25339-J-Z126-1-7600 43 Standard processing in SVP mode Using frames Overview of the SVP function ke ys The f ollowing o ver view sho ws the ke ys and their functions as valid f or most SVP fr ames. In some SVP frames k eys can ha v e another function.
44 U25339-J-Z126-1-7600 Using frames Standard processing in SVP mode PF 18 Step Ex ecutes the ne xt command if the S130 is in Single Cycle Instruction Mode.
U25339-J-Z126-1-7600 45 Standard processing in SVP mode Using frames 6.3.2 Switching between user frames A s witch between the user frames is only possib le within a specified scheme or via an FR command.
46 U25339-J-Z126-1-7600 User frames Standard processing in SVP mode 6.3.3 Options f or switching between frames on the SKP operating terminal The f ollo wing tab le sho ws the options f or s witching to another frame on the SKP operating ter minal. 6.
U25339-J-Z126-1-7600 47 Standard processing in SVP mode User frames 6.4.1 (ML) MODE SELECTION FRAME Figure 15: MODE SELECTION FRAME screen By making entries in this frame and pressing , you can s witch to other frames or e x ecute various basic functions.
48 U25339-J-Z126-1-7600 User frames Standard processing in SVP mode EXECUTION The f ollowing functions are e x ecuted after the appropriate number is entered in the input fields: The functions are e .
U25339-J-Z126-1-7600 49 Standard processing in SVP mode User frames Note The f ollowing tab le shows all the functions that can be meaningfully combined: Function CPU SELECT ST OP/ST AR T MODE Eff ect on: CPU ST OP - 1 All CPU all CPUs 0 ... 7 2 T ARGET CPU selected CPU INTERR UPT ST ORE ST A TUS REST AR T 0 .
50 U25339-J-Z126-1-7600 User frames Standard processing in SVP mode 6.4.2 (LD) PR OGRAM LO AD FRAME: B ASIC Figure 16: PROGRAM LO AD FRAME: BASIC screen An IPL is e x ecuted by entering a load function and pressing the ke y . The predefined parameters in (A U5) A UXILIAR Y FRAME: LOAD PRESET are used.
U25339-J-Z126-1-7600 51 Standard processing in SVP mode User frames 6.4.2.1 (LD) PR OGRAM LO AD FRAME: DET AIL-1 Figure 17: PROGRAM LO AD FRAME: DET AIL-1 screen By making entries in this screen and pressing the ke y you can control the e x ecution of an IPL.
52 U25339-J-Z126-1-7600 User frames Standard processing in SVP mode If IPL is ter minated nor mally , the device address list is transf erred from the PRESET GR OUP to the CURRENT GR OUP . If the IPL is unsuccessful, the ne xt de vice address from the PRESET GR OUP is reloaded.
U25339-J-Z126-1-7600 53 Standard processing in SVP mode User frames DET AIL-2 ST A TUS In this position the current settings of the PROGRAM LO AD FRAME: DET AIL-2 are displa y ed. Chec k the settings . If the y are correct, e x ecute the IPL by pressing .
54 U25339-J-Z126-1-7600 User frames Standard processing in SVP mode 6.4.2.2 (LD) PR OGRAM LO AD FRAME: DET AIL-2 Figure 18: PROGRAM LO AD FRAME: DET AIL-2 screen By making an entr y in this frame and pressing , y ou can set the operating mode.
U25339-J-Z126-1-7600 55 Standard processing in SVP mode User frames Special ke y functions Sets operating mode . If a loading function has previously been stored in PR OGRAM LO AD FRAME: DET AIL-1 with the ke y , an IPL with the set parameters is e x ecuted.
56 U25339-J-Z126-1-7600 User frames Standard processing in SVP mode Figure 20: ST A TUS DISPLA Y FRAME: SSU screen This displa ys inf or mation on the status of the connected global storage. Memor y size , batter y status, po wer status, online status , and connect status are displa yed.
U25339-J-Z126-1-7600 57 Standard processing in SVP mode User frames 6.4.4 (MA) MANU AL OPERA TION FRAME Figure 21: MANU AL OPERA TION FRAME screen By making an entr y in this frame and pressing , y ou can ex ecute various manual operations . Instructions on this frame are only e xecuted when the CPU has been stopped (see message in frame line 23).
58 U25339-J-Z126-1-7600 User frames Standard processing in SVP mode The f ollowing tab le shows the additional entries required f or each of the three main functions in other input fields: RA TE CONT.
U25339-J-Z126-1-7600 59 Standard processing in SVP mode User frames ADRS COMP MODE => Address compare stop mode 1 RESET Switches off address compare stop and resets address compare stop conditions in the fields ADRS TYPE, ADRS COMP SELECT and ADRS SET 2 SET Switches on address compare stop 3 NORMAL Switches off address compare stop 6.
60 U25339-J-Z126-1-7600 User frames Standard processing in SVP mode F A CILITY => P ossible displa ys of memor y areas with various addres- ses: L LOGICAL logical storage address R REAL real storag.
U25339-J-Z126-1-7600 61 Standard processing in SVP mode User frames FUNCTION => The f ollowing functions are e x ecuted after the appropriate letter is entered and is pressed: A AL TER change and m.
62 U25339-J-Z126-1-7600 User frames Standard processing in SVP mode 6.4.6 (ME) MESSA GE FRAME Figure 24: MESSA GE FRAME screen All SVP messages and commands to the SVP are stored in a message file and can be vie wed in the MESSA GE FRAME.
U25339-J-Z126-1-7600 63 Standard processing in SVP mode User frames 6.4.7 (CH) CH/SUBCH ST A TUS DISPLA Y FRAME: CHANNEL Figure 25: CH/SUBCH ST A TUS DISPLA Y FRAME: CHANNEL screen By making entries in the input fields and pressing , y ou can displa y the status of the I/O system.
64 U25339-J-Z126-1-7600 User frames Standard processing in SVP mode LINKADR => link address f or type-S channel 01 without director with director : 00 ... FE output por t address = link address LCU ADR => logische control unit address no input required PCHAD => ph ysical channel address 00 .
U25339-J-Z126-1-7600 65 Standard processing in SVP mode User frames 6.4.8 (A U) A UXILIAR Y FRAME: MENU Figure 26: A UXILIAR Y FRAME: MENU screen Y ou can mov e to other frames b y making entries in this menu frame and pressing .
66 U25339-J-Z126-1-7600 User frames Standard processing in SVP mode 6.4.8.1 (A U1) A UXILIAR Y FRAME: REAL CLOCK Figure 27: A UXILIAR Y FRAME: REAL CLOCK screen When the screen is in vok ed, the current date and time of the SVP are displa y ed. Press the k ey bef ore making an entr y .
U25339-J-Z126-1-7600 67 Standard processing in SVP mode User frames 6.4.8.2 (A U2) A UXILIAR Y FRAME: IORSF CONTROL Figure 28: A UXILIAR Y FRAME: IORSF CONTR OL screen The IORSF files are displa yed in this file. The file n umber of the current IORSF is display ed in the CURRENT NO.
68 U25339-J-Z126-1-7600 User frames Standard processing in SVP mode SPECIFY SW AP NO . <=> Enter two file n umbers which are to be sw apped. Y ou can only make entries if you select function 1 bef orehand. Special ke y functions Sets 4 to 7 are displa yed Sets 0 to 3 are displa yed 6.
U25339-J-Z126-1-7600 69 Standard processing in SVP mode User frames 6.4.8.4 (A U4) A UXILIAR Y FRAME: P-OFF/IMPL Figure 30: A UXILIAR Y FRAME: P-OFF/IMPL screen By making an entr y in this frame and pressing , y ou can switch the S130 off or re- initialize it.
70 U25339-J-Z126-1-7600 User frames Standard processing in SVP mode 6.4.8.5 (A U5) A UXILIAR Y FRAME: LO AD PRESET1 Figure 31: A UXILIAR Y FRAME: LO AD PRESET1 screen Y ou can predefine the e xecutio.
U25339-J-Z126-1-7600 71 Standard processing in SVP mode User frames 1 ENABLE automatically e x ecutes IPL after IMPL 2 DISABLE does not e xecute IPL, i.e . IPL must be triggered manually using PR OGRAM LOAD FRAME: BASIC or PR OGRAM LOAD FRAME: DET AIL-1.
72 U25339-J-Z126-1-7600 User frames Standard processing in SVP mode EXA MODE => Selection of addressing mode 1 ENABLE e xtended XA mode 2 DISABLE not used on the S130 Business Ser ver ST ART IPL NO.
U25339-J-Z126-1-7600 73 Standard processing in SVP mode User frames FUNCTION => The f ollowing functions are carried out by entering the appropriate number : 1 DISPLA Y CFR displa ys current configuration 2 INIT CFR FILE NO . activ ates selected FILE after IMPL, enter a number in the INIT CFR FILE NO.
74 U25339-J-Z126-1-7600 User frames Standard processing in SVP mode 6.4.9 (MF) MSF FRAME Figure 34: MSF FRAME screen The SVP logs all FLA G codes, whereby the most recent code is gener ally shown in line 24.
U25339-J-Z126-1-7600 75 Standard processing in SVP mode User frames F rame line 24: Y ou can s witch to FLA G code entr ies of other components by making the f ollo wing entries in line 24: ssu0: FLA .
76 U25339-J-Z126-1-7600 User frames Standard processing in SVP mode 6.4.10 (P A) PERFORMANCE ANAL YZER Figure 35: PERFORMANCE ANAL YZER FRAME screen The P A fr ame is not intended for use .
U25339-J-Z126-1-7600 77 Standard processing in SVP mode Selecting IORSF 6.5 Examples of standar d pr ocessing in SVP mode 6.5.1 Selecting IORSF The steps listed below are conditions f or the loading of a par ticular IORSF at the next IMPL or the ne xt time the system is s witched on.
78 U25339-J-Z126-1-7600 Selecting IORSF Standard processing in SVP mode The A UXILIAR Y FRAME: MENU screen is displa yed Figure 37: A UXILIAR Y FRAME: MENU screen In voking IORSF Contr ol F rame Ê Enter 2 in the SELECTION=> field.
U25339-J-Z126-1-7600 79 Standard processing in SVP mode Selecting IORSF The A UXILIAR Y FRAME: IORSF CONTR OL screen is display ed: Figure 38: A UXILIAR Y FRAME: IORSF CONTR OL screen The first f our IORSF are displa yed in the upper por tion of the screen.
80 U25339-J-Z126-1-7600 Activ ating IORSF Standard processing in SVP mode 6.5.2 Activ ating IORSF The set IORSF must be activ ated with a IMPL: Conditions Y ou must be in the A UXILIAR Y FRAME: IORSF CONTR OL screen. Ê Press to switch bac k to the A UXILIAR Y FRAME: MENU .
U25339-J-Z126-1-7600 81 Standard processing in SVP mode PROGRAM LOAD FRAME PRESET1 6.5.3 Setting up PR OGRAM LO AD FRAME PRESET1 In this e xample, y ou specify: ● LO AD function 1 with the name A UT.
82 U25339-J-Z126-1-7600 PR OGRAM LO AD FRAME PRESET1 Standard processing in SVP mode The A UXILIAR Y FRAME: LO AD PRESET1 screen is display ed: Figure 40: A UXILIAR Y FRAME : LOAD PRESET1 screen Y ou .
U25339-J-Z126-1-7600 83 Standard processing in SVP mode PROGRAM LOAD FRAME PRESET2 6.5.4 Setting up PR OGRAM LO AD FRAME PRESET2 In the PR OGRAM LOAD FRAME PRESET2 y ou specify which operating mode is to be set after the S130 system is s witched on.
84 U25339-J-Z126-1-7600 IPL in PR OGRAM LO AD FRAME: DET AIL-1 Standard processing in SVP mode Catalog par ameters Ê Press the ke y . The v alues entered are sav ed and thus made known to the SVP .
U25339-J-Z126-1-7600 85 Standard processing in SVP mode IPL in PROGRAM LOAD FRAME: DETAIL-1 In this e xample, the PR OGRAM LOAD FRAME: DET AIL-1 screen is display ed: Figure 42: PROGRAM LO AD FRAME: DET AIL-1 screen LO AD FUNCTION => Enter 3 f or dialog star tup .
86 U25339-J-Z126-1-7600 IPL in PR OGRAM LO AD FRAME: DET AIL-1 Standard processing in SVP mode DET AIL-2 ST A TUS The settings in DET AIL-2 FRAME are displa y ed in detail.
U25339-J-Z126-1-7600 87 Standard processing in SVP mode Setting operating mode 6.5.6 Setting operating mode via PR OGRAM LO AD FRAME: DET AIL-2 The operating mode can be reset using the PR OGRAM LOAD FRAME: DET AIL-2. This selects the appropriate fir mware f or r unning BS2000 or VM2000.
88 U25339-J-Z126-1-7600 Setting operating mode Standard processing in SVP mode Activating settings Ê After y ou hav e check ed all the settings, press . The f ollowing prompt appears: Press to ex ecute the IPL or to cancel the procedure. Confir m your input with .
U25339-J-Z126-1-7600 89 7 Operating the BS2000 console Selecting the console window At the operator terminal, you enter system operating mode b y clicking the windo w CONS0 #1<computer name> with the left mouse button. System operation When the BS2000 console window is opened, no input is permitted.
Eine Dokuschab lone v on F rank Flachenec k er b y f .f . 1992.
U25339-J-Z126-1-7600 91 8 T r oubleshooting This chapter describes what to do out in case of malfunction. 8.1 Pr oblems with the S130 In the case of a prob lem with the S130, contact the ser vice depar tment and discuss the steps to be tak en.
92 U25339-J-Z126-1-7600 Pr oblems with the S130 Troubleshooting 8.1.1 Displa ys in the case of a hard ware error The S130 inf or ms you of hardw are errors in the f ollowing manner : ● On the S130 control panel If the y ellow CHECK light illuminates, there ma y be a hardw are error .
U25339-J-Z126-1-7600 93 Troubleshooting Problems with the S130 8.1.2 Carrying out a system dump Conditions: 1. Select the SVPST0 window 2. Select LD PR OGRAM LOAD FRAME 3. Select LO AD FUNCTION => 5 (SYSTEM DUMP) The system dump stored on hard disk or cassette b y the DUMP program is required f or error diagnosis.
94 U25339-J-Z126-1-7600 Pr oblems with the S130 Troubleshooting List of I/O channels: IOP0 (channel processor CHP 0 and 1) channel range 00 to 7F IOP1 (channel processor CHP 2 and 3) channel range 80 to FF If the first I/O processor (IOP0) f ails, system oper ation is no longer possib le due to the lac k of a console.
U25339-J-Z126-1-7600 95 Troubleshooting Problems with the S130 Ê Once the message SHUTDOWN COMPLETED is display ed, s witch the S130 to CE mode by s witching the CE ke y on the inside of the maintenance panel of the S130 to the position “Maintenance Mode On”.
96 U25339-J-Z126-1-7600 Pr oblems with the S130 Troubleshooting Ê Press the ke y to retur n to the Index F rame . Ê Select the frame A U4 by entering the frame code AU4 and press the ke y . Ê Select the IMPL function b y enter ing 2 (IMPL activ ates the new setting) and confir m y our input by pressing the k ey .
U25339-J-Z126-1-7600 97 Troubleshooting Problems with the service/console processor (SKP) 8.2 Pr oblems with the service/console pr ocessor (SKP) If y ou hav e problems with the SKP , contact the ser vice depar tment and discuss the steps to be tak en.
98 U25339-J-Z126-1-7600 Impor tant key combinations Troubleshooting 8.3 Impor tant key combinations If y our mouse is not wor king, y ou can use the ke ys + to mov e between the windows of the X-Windo ws window system.
U25339-J-Z126-1-7600 99 Related publications Please apply to y our local office for ordering the manuals . [1] SINIX-2000 V7.0 Installation, Operation and Administration User Guide T ar get gr oup Th.
100 U25339-J-Z126-1-7600 Related publications [4] TELESER VICE - TSB2000 (BS2000/OSD Ser ver) User Guide T ar get gr oup The manual addresses the oper ating personnel of the C50, C70, C80, H100, S110, S130 and SR2000 mainframes . Kno wledge of BS2000 and basic SINIX knowledge are required to operate TELESER VICE.
U25339-J-Z126-1-7600 101 Inde x A AL TER/DISPLA Y FRAME (AD) 59 AL TER/DISPLA Y FRAME (subframe) 60 A T OP 8 s witching the S130 on/off 31 authorization control 10 AU TO 8 1 A UXILIAR Y FRAME IORSF CO.
102 U25339-J-Z126-1-7600 Index D displa y hardware errors 92 hardware status 41 displa ys in line 24 41 in line 25 41 E emergencies 3 EMERGENCY ST OP s witch 19 batter y cabinet 19 global storage 19 e.
U25339-J-Z126-1-7600 103 Index L line 22 + 23, messages 38 line 23, messages 40 line 24, displa ys 41 line 25, displa ys 41 loading BS2000 33 loading IORSF 77 M manual IPL 84 MANU AL OPERA TION FRAME .
104 U25339-J-Z126-1-7600 Index S S130 control panel 12 b utton functions 15 function of the indicators 12 saf ety instr uctions 3 SCI (System Control Interf ace) 96 SCI def ective 96 screen A UXILIAR .
U25339-J-Z126-1-7600 105 Index automatically 28 b y hand 21 from a remote system 32 from SKP 23 time-driven 30 using the control panel 21 system components def ective 96 system operation 7 system stat.
Eine Dokuschab lone v on F rank Flachenec k er b y f .f . 1992.
U25339-J-Z126-1-7600 107 Contents 1 Intr oduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.1 Objectiv es and target group . . . . . . . . . . . . . . . . . . . . . . . . . .
108 U25339-J-Z126-1-7600 Contents 6 Standar d processing in SVP mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 6.1 In voking an SVP frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
U25339-J-Z126-1-7600 109 Contents 8 T roub leshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91 8.1 Prob lems with the S130 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Eine Dokuschab lone v on F rank Flachenec k er b y f .f . 1992.
U25339-J-Z126-1-7600 111 S130 Business Server Operating Manual T ar get gr oup The manual addresses privileged users (operators , system administrators) of the S130 Business Ser ver . Contents The manual describes the hardware of the S130 Business Ser v er insof ar as it is required f or system operation.
Een belangrijk punt na aankoop van elk apparaat Siemens BS2000/OSD (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Siemens BS2000/OSD heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Siemens BS2000/OSD vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Siemens BS2000/OSD leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Siemens BS2000/OSD krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Siemens BS2000/OSD bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Siemens BS2000/OSD kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Siemens BS2000/OSD . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.