SRP-X500P RS-232C Interface Manual 1. Overview 1.1 About This Manual This manual is the Interface Manual for the Sony SRP-X500P Digital Powered Mixer . The protocol explained in this manual is designed for controlling the SRP-X500P Digital Powered Mixer from an externally connected computer .
SRP-X500P RS-232C Interface Manual 1.3 Communication Format The communication format is described below . Baud rate : 38,400 bps Communication mode : Half-duplex start stop system (asynchronous) Data length : 8 bits Parity bit : odd Stop bit : 1 bit Flow control : None 1.
SRP-X500P RS-232C Interface Manual 1.7 Handshake Codes ACK : 0x41 ( ‘A’ ) When the SRP-X500P has received a command from an external computer and has processed it successfully , it returns an ACK to the computer as notification that th e comm and has been executed.
SRP-X500P RS-232C Interface Manual 2. Command Reference 2.1 Basic Control Commands The following commands are provided to perform basic control on the SRP-X500P such as volume level control and channel input selection.
SRP-X500P RS-232C Interface Manual Return packet format When the SRP-X500P receives a command successfully , th e parameter is returned together with an ACK (0x41 (‘A ’)) in the order shown below . 0x41 “ parameter” 0x0D The parameter is the same as that of the A V/RGB INPUT SELECT command.
SRP-X500P RS-232C Interface Manual • FADER (1st-6th byte) The level for each fader can be specified (in dB units). The parameter and levels are as shown in the following table. Level Level Level Level - ∞ 0x30 (‘0’) -20.0 0x40 (‘@’) -4.5 0x50 (‘P’) +3.
SRP-X500P RS-232C Interface Manual 2.1.5 OUTPUT FADER : 0x43 0x50 0x4D 0x40 (‘CPM@’) This command is used to set th e level of the output faders. The parameter specified by this command functions in the same way as the output faders in the OVER VIEWscreen of the SRP-X500P Manager .
SRP-X500P RS-232C Interface Manual Return packet format When the SRP-X500P receives the command successfully , th e parameter is returned together with an ACK (0x41 (‘A ’)) in the order shown below . 0x41 “ parameter” 0x0D The parameter consists of 8 bytes of data and is the same as that of the OUTPUT F ADER command.
SRP-X500P RS-232C Interface Manual • LEVEL (2nd byte) The level for each fader can be specified (in dB units). The parameter and the level are as shown in the following table. Level Level Level - ∞ 0x30 (‘0’) -20.0 0x40 (‘@’) -4.5 0x50 (‘P’) -70.
SRP-X500P RS-232C Interface Manual ♦ Parameter The parameter consists of 7 bytes of data in the order shown in the following table. Byte Parameter 1st MASTER VOLUME LEVEL 2nd REMOTE 1 LEVEL 3rd REMO.
SRP-X500P RS-232C Interface Manual 2.1.10 MASTER VOLUME DOWN : 0x43 0x4C 0x56 0x2D (‘CLV-’) This command is used to tu rn down the master volume. When this command is transmitted, the volume leve l decreases continuously . When the MASTER VOLUME STOP command (page 13) is transmitted, the volume level stops decreasing.
SRP-X500P RS-232C Interface Manual 2.1.12 MUTING : 0x43 0x4D 0x55 0x54 (‘CMUT’) This command is used to turn of f the specified channel ( “ Muting on”) or turn the channel back on ( “ Muting of f”).
SRP-X500P RS-232C Interface Manual Example T o turn off REMOTE fader 1( “ Muting on”): 0x43 0x4D 0x55 0x54 0x42 0x41 0x0D (‘C M U T B A CR’) 2.1.13 MUTING PARAMETER REQUEST : 0x52 0x4D 0x55 0x54 (‘RMUT’) This command is used to read th e muting status of the SRP-X500P .
SRP-X500P RS-232C Interface Manual • LINE OUTPUT MUTING (3rd byte) Shows the muting status of the LINE OUTPUT ch annels in the form of 8 bits of data. The bit is 0 for a channel which is not turned off ( “ Muting off”) and 1 for a channel which is turned off ( “ Muting on”).
SRP-X500P RS-232C Interface Manual 2.1.14 PROJECTOR ON/STANDBY : 0x43 0x50 0x4A 0x50 (‘CPJP’) This command is used to change the power status (on or standby status) of the projector connected to the PROJECTOR CONTROL connector . Packet format 0x43 0x50 0x4A 0x50 “ parameter” 0x0D ♦ Parameter The parameter consists of 1 byte of data.
SRP-X500P RS-232C Interface Manual • PROJECTOR ON/STANDBY INDICATOR (1st byte) Shows the status of the PROJECTOR ON/ST ANDBY POWER switch. The parameter and the status of the PROJ ECTOR ON/ST ANDBY POWER switch are as shown in the following table. PROJECTOR ON/ST ANDBY INDICA TOR ST ANDBY (The switch lights up red.
SRP-X500P RS-232C Interface Manual 2.1.17 SCENE RECALL PARAMETER REQUEST : 0x52 0x52 0x43 0x4C (‘RRCL’) This command is used to read the r ecalled scene number from the SRP-X500P .
SRP-X500P RS-232C Interface Manual 2.2 Status Acquisition Commands The following commands are used to acquire th e settings and the status of the SRP-X500P . 2.2.1 INDEX REQUEST : 0x52 0x50 0x4D 0x44 (‘RPMD’) This command is used to read the index names of all input/output connectors of the SRP-X500P .
SRP-X500P RS-232C Interface Manual Example When the input/output channels are specified with the index names as follows: MIC 1/WL 1 INPUT : MIC □ 1 MIC 2/WL 2 INPUT : MIC □ 2 MIC 3 INPUT : MIC.
SRP-X500P RS-232C Interface Manual ♦ Parameter The parameter consists of 16 bytes of data in the order shown in the following table. Byte Parameter 1st MIC 1/W L 1 INP UT LEVEL METER 2nd MIC 2/WL 2 .
SRP-X500P RS-232C Interface Manual Example When the level meter r eadings are as follows : MIC 1/WL 1 INPUT LEVEL METER : Less than -30 [VU] MIC 2/WL 2 INPUT LEVEL METER : -30 [VU] MIC 3 INPUT LEV.
SRP-X500P RS-232C Interface Manual To acquire the status of all items T ransmit the following command to acquire the status of all items available using the ST A TUS REQUEST command.
SRP-X500P RS-232C Interface Manual Parameters The parameter consists of 108 bytes of data, as shown in the following table. Byte (when acquiring all items at one time) Parameter Specified value (w.
SRP-X500P RS-232C Interface Manual ♦ PROJECTOR PROTOCOL SWITCH (1st byte) SYSTEM TYPE SWITCH (2nd byte) Shows the position of the PROJECTOR PROT OCOL se lector or the SYSTEM TYPE s elector on the front panel of the SRP-X500P . The parameters and the switch position are shown in the following table.
SRP-X500P RS-232C Interface Manual ♦ INPUT LEVEL (16th-21st byte) Shows the value indicated by the yellow triangular ma rker at the side of the input fader in the OVER VIEW screen of the SRP-X500P Manager .
SRP-X500P RS-232C Interface Manual ♦ OUTPUT MUTING (31st and 32nd byte) Shows the muting status of the output channels. The OUTPUT MUTING parameter consists of the 2 byte s of data in the order shown in the following table.
SRP-X500P RS-232C Interface Manual ♦ RF/AF INDICATOR (36th byte) Shows the status of the RF and AF indicators on th e front panel of the SRP-X500P in the form of 8 bits of data. The bit is 0 for indicators that are turned of f and 1 for indicators that are turned on.
SRP-X500P RS-232C Interface Manual ♦ LINE TRIM (43rd byte) Shows the setting of the TRIM controls for the LI NE input on the front panel of the SRP-X500P (in dBu units).
SRP-X500P RS-232C Interface Manual ♦ FR (50th-53rd byte) The FR parameter consists of the 4 bytes of da ta in the order shown in the following table. Byte Parameter 1st MIC 1/WL 1 FR 2nd MIC 2/WL 2 FR 3rd MIC 3 FR 4th MIC 4 FR • FR Shows the status of the FEED BACK REDUCER.
SRP-X500P RS-232C Interface Manual • SETUP STATUS Shows the progress of the FEED BACK REDUCER setting. The parameter and the progress are as shown in the following table.
SRP-X500P RS-232C Interface Manual ♦ IR OUTPUT MODE INDICATOR (59th byte) Shows the status of the IR OUTPUT MODE button on the front panel of the SRP-X500P . The correspondence of the parameter with the IR OUTPUT MODE button status is shown in the following table.
SRP-X500P RS-232C Interface Manual ♦ TEMPERATURE (78th and 79th byte) The TEMPERA TURE parameter consists of 2 bytes of data in the order shown in the following table. Byte Parameter 1st SPEAKER OUTPUT CH1/2 TEMPERA TURE 2nd SPEAKER OUTPUT CH3/4 TEMPERA TURE • TEMPERATURE Shows the temperature of the heat si nk in the power am plifier section.
SRP-X500P RS-232C Interface Manual ♦ SCENE No. (84th byte) Shows the scene number to be recalled. The parameter and the scene number are shown in the following table.
SRP-X500P RS-232C Interface Manual • OUTPUT 1-6 Shows the on/off status of output pins 1 to 6 of the REMOTE P ARALLEL connector in 8 bits of data. When an output pin is off, the corresponding b it is 0, and when an output pin is on, the corresponding bit is 1.
SRP-X500P RS-232C Interface Manual ♦ GAIN REDUCTION (99th-108th byte) The GAIN REDUCTION parameter consists of the 8 byte s of data in the order shown in the following table.
SRP-X500P RS-232C Interface Manual • COMPRESSOR GAIN REDUCTION Indicatess the gain reduction level read ing of the COMPRESSOR (in dB units). The parameter and the gain reduction level reading are shown in the following table.
SRP-X500P RS-232C Interface Manual 2.3 Maintenance Information Commands The following commands are provided to read and write the information on the SRP-X500P and to restore the parameters to their factory default settings. 2.3.1 INFORMATION REQUEST : 0x52 0x50 0x4D 0x45 (‘RPME’) This command is used to read information from the SRP-X500P .
SRP-X500P RS-232C Interface Manual 2.3.2 MAINTENANCE INFORMATION READ WRITE : 0x43 0x4D 0x49 0x31 (‘CMI1’) This command is used to enter inform ation in the 256-byte readable/writabl e area in the maintenance information memory of the SRP-X500P .
SRP-X500P RS-232C Interface Manual 2.3.3 MAINTENANCE INFORMATION READ WRITE REQUEST : 0x52 0x4D 0x49 0x31 (‘RMI1’) This command is used to read the in formation entered in the 256-byte read able/writable area in the maintenance information memory of the SRP-X500P .
SRP-X500P RS-232C Interface Manual Example When the RMI2 command is received: 0x41 0x53 0x52 0x50 0x2D 0x58 0x35 0x30 0x30 0x50 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x2.
SRP-X500P RS-232C Interface Manual Example When the version is 1.00 0x41 0x31 0x2E 0x30 0x30 0x20 0x20 0x20 0x20 0x20 (‘A 1 . 0 0 □ □ □ □ ’) “ □ ” indicates a space. 2.3.6 FACTORY PRESET : 0x43 0x52 0x53 0x54 (‘CRST’) This command is used to restore the parameters of the SRP-X500P to their factory default setting.
Een belangrijk punt na aankoop van elk apparaat Sony SRP-X500P (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Sony SRP-X500P heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Sony SRP-X500P vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Sony SRP-X500P leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Sony SRP-X500P krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Sony SRP-X500P bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Sony SRP-X500P kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Sony SRP-X500P . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.