VFC Radiant & Convector Fire Range With upgradeable control valve Instructions for Use, Installation and Servicing For use in GB, IE (Great Britain and Eire) IMPORTANT The chimney must be swept before installation. Do not attempt to burn rubbish on this fire.
2 CONTENTS VFC RADIANT VFC CONVECTOR VFC LOW CONVECTOR 8300UC 16” 8420UC 16” 8461UC 16”LL P8300UC 16” P8420UC 16” P8461UC 16”LL 8301UC 16”RD 8421UC 16”RD 8463UC 16”RD LL P8301UC 16.
3 FLUE CHECK PASS FAIL 1. Flue is correct for appliance 2. Flue flow test 3. Spillage test GAS CHECK 1. Gas soundness & let by test 2. Standing pressure test mb 3. Appliance working pressure (on High Setting) mb NB All other gas appliances must be operating on full 4.
4 USER INSTRUCTIONS 1. GENERAL 1.1 Installation and servicing must only be carried out by a competent person. 1.2 In your own interest, and those of safety, this appliance must be installed by a competent person in accordance with local and national codes of practice.
7. ARRANGEMENT OF FUEL BED COMPONENTS ADVICE ON HANDLING AND DISPOSAL OF FIRE CERAMICS The fuel effect and side panels in this appliance are made from Refractory Ceramic Fibre (RCF), a material which is commonly used for this application.
7 AR1118 7.8 Place the remaining 4 small coals on top of the others so that they form a bridge between the second and third rows. See Diagram 8. 8 AR1119 18” COAL LAYOUT 7.9 Curved fronts (Holyrood) - place 6 large coals onto the front coal moulding ensuring that they rest against the front.
7 USER INSTRUCTIONS 10 AR1121 7.11 Place 6 large coals onto the flame baffle fingers. See Diagram 11. 11 AR1122 7.12 Place 5 large coals so that they form a bridge between the other 2 rows, then 2 small coals, 1 at each end. Place 5 large coals at the back of the fire.
8 10.’RUNNING IN’ The surface coating on the coals used in your GAZCO fire will ‘burn off’ during the first few hours of use, producing a harmless and temporary odour. This will disappear after a short period of use. If the odour persists, ask your installer for advice.
9 TECHNICAL SPECIFICATION THESE INSTRUCTIONS COVER THE FOLLOWING MODELS: VFC RADIANT VFC CONVECTOR VFC LOW CONVECTOR 8300UC 16” 8420UC 16” 8461UC 16”LL P8300UC 16” P8420UC 16” P8461UC 16”L.
10 The flue must be installed in accordance with all local and national regulation and the current rules in force. 1.FLUE AND CHIMNEY REQUIREMENTS 1.1 The chimney or flue system must comply with the rules in force, and must be a minimum of 178mm (7") in diameter.
11 1A VFC Radiant 1B VFC Convector 4.4 The appliance must be firmly fixed to the hearth. Fasteners are provided for this purpose. 4.5 Ensure that no naked flame or incandescent part of the fire bed projects beyond the vertical plane of the fireplace opening.
4. INSTALLATION - RADIANT FIRES 4.1 Fix the rear leg strap. See Diagram 1. 1 AR0019 4.2 Position the fire with the rear leg fully engaged under the rear leg strap. Fasten the front legs using the fixings supplied. 4.3 “HAVE YOU PURGED THE GAS SUPPLY PIPES”.
13 4.6 Check the gas connections to the fire are sound. Light the fire and check all joints on the appliance. 4.7 Check the appliance running pressure is correct. See databadge. 4.8 Fit the fret to the fire front using two screws. See Diagram 4. 4 AR0311 5.
11 AR0303 5.13 Fit the fret to the fire front using the two securing screws. See Diagram 12. 12 AR0311 5.14 If the appliance is fitted with an alternative Gazco front please refer to the separate leaflet supplied with the front.
15 NOTE: CERAMIC PARTS ARE FRAGILE. 6.1 Position the flame baffle on the rear of the tray. See Diagram 13 arrow B. 6.2 Position the front coal, make sure it sits flat onto the burner skin. See Diagram 13 arrow C. 13 AR2190 6.3 Place the coals following the appropriate Diagrams and Instructions: 16” AND REDUCED DRAUGHT COAL LAYOUT 6.
16 18” COAL LAYOUT 6.9 Curved fronts (Holyrood) - Place 6 large coals onto the front coal moulding ensuring that they rest against the front. Place 2 small coals onto the front coal, 1 at each end.
17 INSTALLATION INSTRUCTIONS INSTALLATION 25 AR1127 6.16 Place 7 large coals so that they form a bridge between the other 2 rows, and 2 small coals, 1 at each end.
18 1. COMMISSIONING 1.1 Close all windows and doors to the room, check all controls, and allow fire to burn on maximum for 5 minutes. Test for spillage of flue products using a smoke match. For standard VFC fires, pass the lighted smoke match along the top front edge just inside the opening or canopy.
19 This appliance must be serviced at least one a year by a competent person. 1. SERVICING REQUIREMENTS 1.1 As part of the annual service, the space behind the convector must be inspected for any debris, which may have fallen down the chimney. 1.2 Remove the gas fire from the convector as detailed in section 4 1.
20 FAULT FINDING IGNITION FUNCTIONAL CHECK 1 PILOT WILL NOT LIGHT Ensure there is no debris around the pilot assembly, e.g coal, soot, etc which could short the spark, clean the area. Check for fluff in the pilot aeration hole. See Diagram 7, arrow A.
21 SERVICING INSTRUCTIONS REPLACING PARTS The following part can be serviced without removing the fire. 2. IGNITION LEAD 2.1 Turn off the gas supply at the isolation device. 2.2 Remove the fret. See Diagram 1. 1 AR0311 2.3 Undo the single screw that secures the left hand side of the control cover.
22 5. ODS PILOT UNIT Note: The pilot unit on the appliance is a non serviceable unit due to the complex nature of its manufacture. Replacement of the complete unit must be carried out if one of the following items becomes faulty: Pilot injector Ignition electrode Thermocouple 5.
23 6.4 To release the right hand side of the control cover insert the narrow blade screwdriver into the slot shown in Diagram 10, lever it gently and pull from the right hand side at the same time. The cover will now come off, there is a small cylindrical metal spacer inside the cover.
MANUAL FIRES RD 16 18 22 CERAMIC PARTS Front Coal LH CE0151 CE0152 CE0153/54 Flame Baffle CE0119 CE0120 CE0121 Burner Skin CE0155 CE0156 CE0157 Coal Set CE0394 CE0395 CE0396 Convector Side Cheek LH CE.
25 SERVICE RECORDS 1ST SERVICE Date of Service:........................................................................... Next Service Due:....................................................................... Signed:................................
Gazco Limited, Osprey Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7JG Technical Customer Services (01392) 261950 Fax: (01392) 261951 E-mail: technicalserviceds@gazco.
Een belangrijk punt na aankoop van elk apparaat Stovax 8455 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Stovax 8455 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Stovax 8455 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Stovax 8455 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Stovax 8455 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Stovax 8455 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Stovax 8455 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Stovax 8455 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.