E-Studio ™ & E-box ™ Balanced Flue With upgradable control valve Instructions for Use, Installation and Servicing For use in GB, IE (Great Britain and Eire) This appliance has been certified for use in countries other than those stated.
2 CONTENTS Covering the following models: 8692BFCHUC 8692MCUC 8692PBUC P8692BFCHUC P8692MCUC 8692PBUC APPLIANCE COMMISSIONING CHECKLIST 3 USER INSTRUCTIONS 4 INSTALLATION INSTRUCTIONS 11 Technical Spe.
FLUE CHECK PASS FAIL 1. Flue is correct for appliance 2. Flue flow test N/A 3. Spillage test N/A GAS CHECK 1. Gas soundness & let by test 2. Standing pressure test mb 3. Appliance working pressure (on High Setting) mb NB All other gas appliances must be operating on full 4.
4 USER INSTRUCTIONS 1. GENERAL 1.1 Installation and servicing must only be carried out by a competent person. 1.2 In all correspondence, please quote the appliance type and serial number, which can be found on the databadge adjacent to the control knob.
5 USER INSTRUCTIONS TIMER MODE it will turn the fire on and off according to pre-setprogramme and automaticallyregulate theroom temperature during the two periods. GAZCO PART NO. 8456. CLEANING THE FIRE ENSURE THE FIRE IS COLD BEFORE PROCEEDING 5.
6 6A. ARRANGEMENT OF THE FUEL BED COMPONENTS - E STUDIO ONLY USE THE CORRECT TYPE AND QUANTITY OF GRANITE CHIPPINGS. ALWAYS FOLLOW THE FUEL BED LAYOUT AS STATED IN THESE INSTRUCTIONS. NEVER CHANGE THE LAYOUT FROM THAT SHOWN HERE. 6.1 • Arrangethe granite chippingsin theareas highlightedin Diagram 4.
7 • Refer to the separate Frame Instructions to replace the frame on the fire 6B. ARRANGEMENT OF THE FUEL BED COMPONENTS - E-BOX NOTE: CERAMIC PARTS ARE FRAGILE. HANDLE WITH CARE ONLY USE THE CORRECT TYPE AND QUANTITY OF CERAMIC COMPONENTS 6.
8 14 AR1364 • Place2 medium-size coalseither sideof thefirst large coal, in the recess between the flame baffle and the front coal, Diagram 15. 15 AR1365 • Placeanother two mediumsize coalsbehind thefirst three coals and against the flame baffle, Diagram 16.
9 USER INSTRUCTIONS 21 AR1408 A4 A5 A3 A6 • Placethe next fourpebbles asshown restingbetween the flame baffle and the first row of pebbles, Diagram 22. 22 AR1409 A1 A2 A1 • Placethe remaining twoA3 pebblesas shownin Diagram 23.
10 USER INSTRUCTIONS 10. VENTILATION 10.1 This appliance requires no additional ventilation. 11. INSTALLATION DETAILS 11.1 To assist in any future correspondence, your installer should have completed the commissioning sheet at the front of this book, this records the essential installation details of the appliance.
11 INSTALLATION INSTRUC TIONS TECHNICAL SPECIFICATION Covering the following E-STUDIO models: 8692BFCHUC P8692BFCHUC GAS CATEGORY I 2H I 3P Natural Propane Gas Type G20 G31 Working Pressure 20mbar 37mbar Gross Input kW HIGH LOW 4.3kW 3.75kW 2.5kW 2.3kW Gas Rate m 3 /hr 0.
12 INSTALLATION INSTRUC TIONS TECHNICAL SPECIFICATION Covering the following E-BOX models: 8692 MCUC 8692PBUC P8692 MCUC P8692PBUC ** The Arts Frame must be used in conjunction with either the Arts, Holyrood or Spanish Front. GAS CATEGORY I 2H I 3P Natural Propane Gas Type G20 G31 Working Pressure 20mbar 37mbar Gross Input kW HIGH LOW 4.
13 INSTALLATION INSTRUC TIONS TECHNICAL SPECIFICATION OVERALL EXTERNAL DIMENSIONS FOR BOTH E-STRUDIO AND E-BOX AR1427 MININUM AND MAXIMUM FLUE SIZE AR1428 AR1429 MINIMUM FLUE LENGTH MAXIMUM FLUE LENGT.
14 INSTALLATION INSTRUC TIONS SITE REQUIREMENTS 1. FLUE AND CHIMNEY REQUIREMENTS NOTE: This appliance can only be installed in conjunction with the flue supplied. 1.1 The flue must be sited in accordance with BS5440: Part 1 (latest edition), Diagram 1.
15 INSTALLATION INSTRUC TIONS SITE REQUIREMENTS TIMBER FRAMED BUILDINGS 1.5 It will be necessary to provide additional clearance when the flue passes through a wall containing any combustible materials so as to prevent a fire hazard.
16 INSTALLATION INSTRUC TIONS INSTALLATION 1. UNPACKING 1.1 • Removethe appliance fromits packaging,and checkthat it is complete and undamaged • Putthe loose ceramicparts toone sideso thatthey are not damaged during installation.
17 1 AR1435 B A 5.2 Gaspipe entry mustcome throughthe rearright-hand side of the box. The rubber seal must be cut using a sharp knife to allow the isolating elbow to pass through it. • Ensurethe rubber isnot damagedwhen doingthis, Diagram 1, arrow B.
18 INSTALLATION INSTRUC TIONS INSTALLATION 6.6 The void into which the appliance is fitted must be ventilated to prevent a build up of heat. If the void is sealed then it will be necessary to fit vents at both low and high levels of approximately 50cm 2 .
19 5 AR1997 10 A • Ensurethat no chippingsover-hang orfill thepilot area, Arrow B, Diagram 11. NOTE: CHIPPINGS SHOULD NOT BE PLACED DIRECTLY IN FRONT OF THE PILOT CROSS LIGHTING FLAME.
20 15 AR1362 • Placethe front coalcentrally inthe channelat thefront of the tray. The relationship between the front coal and the flame baffle is shown, Diagram 16. 16 AR1363 6.5 There are three sizes of coal used.
21 INSTALLATION INSTRUC TIONS INSTALLATION 18 AR1364 • Place2 medium sizecoals eitherside ofthe firstlarge coal, in the recess of the front coal between the flame baffle and the front coal, Diagram 19.
22 27 AR1410 A3 A3 9.5 The coals/pebbles should evenly cover the whole bed with the gaps between them kept equal. This will maximise the performance of the product. 9.6 ENSURE THAT THE COALS/PEBBLES ARE POSITIONED AS ABOVE. ONLY USE THE CORRECT AMOUNT OF COALS/PEBBLES AS SPECIFIED IN THE DIAGRAMS.
23 11. COMMISSIONING 11.1 Check all ceramics, doors etc. 11.2 Check flame picture 11.3 Check gas pressure 10. LIGHTING THE APPLIANCE 10.1 • Locatethe control valveon thefire.
24 1. SERVICING REQUIREMENTS This appliance must be serviced at least once a year by a competent person. All tests must be serviced by best practice as described by the current CORGI recommendations.
25 SERVICING INSTRUCTIONS FAULT FINDING CHARTS PILOT WILL NOT STAY LIT OR FIRE GOES OUT IN USE Ensure there is no debris around the pilot assembly, (e.g. soot etc.) Problem is with the pipework or fittings which lead to the fire. Correct and retry. Is thermocouple connection good in back of valve? Replace thermocouple.
26 5 AR1999 2 • Carefullyremove the enamelback panelby rotatingit out of the fire box, Diagram 3 5 AR1880b 3 TAKE EXTREME CARE WHILST REMOVING THESE PANELS NOT TO S.
27 • Removethe ceramic coalsand fuelbed andplace ona dry clean surface • Removethe ceramic panelsfrom insidethe appliance • Removethe two screwssecuring thefront Uchannel on the burner assembly.
28 5. ELECTRODE 5.1 • Pullthe ignition leadfrom theelectrode andundo the retaining nut, Diagram 12 12 AR1349 • Replacewith new electrode.Do notover tightenthe nut as this could break the new component • Replacethe ignition lead 6.
29 16 AR0916 • Disconnectthe ignition leadfrom thevalve and electrode. ( For E-Studio , the sealing plate needs also to be removed, Diagram 14) • Replacewith a newignition leadfollowing thesame route as the old one.
30 19 AR1433 • Rotatethe injector untilit isfully removed • Replacewith the correctreplacement injector.When ordering, always state the model, gas type and serial number. • Reassembleand turn thegas supplyon, checkfor any leaks 12.
31 13B. SPARE PARTS LIST - E-BOX CERAMIC PARTS COAL PEBBLE Front Coal / Pebble CE0490 CE0502 FlameBafe CE0491 CE0503 Side Panel LH CE0518 CE0562 Side Panel RH CE0519 CE0563 Rear Panel CE0497 CE0.
32 SERVICE RECORDS 1ST SERVICE Date of Service:........................................................................... Next Service Due:....................................................................... Signed:................................
Gazco Limited, Osprey Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7JG Tel: Technical Customer Services (01392) 261950 Fax: (01392) 261951 E-mail: technicalservices@gazco.
Een belangrijk punt na aankoop van elk apparaat Stovax PR0776 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Stovax PR0776 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Stovax PR0776 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Stovax PR0776 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Stovax PR0776 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Stovax PR0776 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Stovax PR0776 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Stovax PR0776 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.