Symbol Technologies, Inc. One Symbol Plaza, Holtsville N.Y. 11742

Product Reference Guide
70-13584-01 · Revision C · June 1999

©1999 by Symbol Technologies, Inc. All rights reserved.
No part of this publication may be reproduced or used in any form, or by any electrical or mechanical means, without permission in writing from Symbol. This includes electronic or mechanical means, such as photocopying, recording, or information storage and retrieval systems. The material in this manual is subject to change without notice.
The software is provided strictly on an “as is” basis. All software, including firmware, furnished to the user is on a licensed basis. Symbol grants to the user a non-transferable and non-exclusive license to use each software or firmware program delivered hereunder (licensed program). Except as noted below, such license may not be assigned, sublicensed, or otherwise transferred by the user without prior written consent of Symbol. No right to copy a licensed program in whole or in part is granted, except as permitted under copyright law. The user shall not modify, merge, or incorporate any form or portion of a licensed program with other program material, create a derivative work from a licensed program, or use a licensed program in a network without written permission from Symbol. The user agrees to maintain Symbol’s copyright notice on the licensed programs delivered hereunder, and to include the same on any authorized copies it makes, in whole or in part. The user agrees not to decompile, disassemble, decode, or reverse engineer any licensed program delivered to the user or any portion thereof.
Symbol reserves the right to make changes to any software or product to improve reliability, function, or design.
Symbol does not assume any product liability arising out of, or in connection with, the application or use of any product, circuit, or application described herein.
No license is granted, either expressly or by implication, estoppel, or otherwise under any Symbol Technologies, Inc., intellectual property rights. An implied license only exists for equipment, circuits, and subsystems contained in Symbol products.
Symbol, Spectrum One, and Spectrum24 are registered trademarks of Symbol Technologies, Inc. Other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies and are hereby acknowledged.
Symbol Technologies, Inc. One Symbol Plaza Holtsville, New York 11742-1300 http://www.symbol.com
Patents This product is covered by one or more of the following U.S. and foreign Patents: U.S. Patent No.4,360,798; 4,369,361; 4,387,297; 4,460,120; 4,496,831; 4,593,186; 4,603,262; 4,607,156; 4,652,750; 4,673,805; 4,736,095; 4,758,717; 4,816,660; 4,845,350; 4,896,026; 4,897,532; 4,923,281; 4,933,538; 4,992,717; 5,015,833; 5,017,765; 5,021,641; 5,029,183; 5,047,617; 5,103,461; 5,113,445; 5,130,520 5,140,144; 5,142,550; 5,149,950; 5,157,687; 5,168,148; 5,168,149; 5,180,904; 5,229,591; 5,230,088; 5,235,167; 5,243,655; 5,247,162; 5,250,791; 5,250,792; 5,262,627; 5,262,628; 5,266,787; 5,278,398; 5,280,162; 5,280,163; 5,280,164; 5,280,498; 5,304,786; 5,304,788; 5,306,900; 5,321,246; 5,324,924; 5,337,361; 5,367,151; 5,373,148; 5,378,882; 5,396,053; 5,396,055; 5,399,846; 5,408,081; 5,410,139; 5,410,140; 5,412,198; 5,418,812; 5,420,411; 5,436,440; 5,444,231; 5,449,891; 5,449,893; 5,468,949; 5,471,042; 5,478,998; 5,479,000; 5,479,002; 5,479,441; 5,504,322; 5,519,577; 5,528,621; 5,532,469; 5,543,610; 5,545,889; 5,552,592; 5,578,810; 5,581,070; 5,589,679; 5,589,680; 5,608,202; 5,612,531; 5,619,028; 5,664,229; 5,668,803; 5,675,139; 5,693,929; 5,698,835; 5,705,800; 5,714,746; 5,723,851; 5,734,152; 5,734,153; 5,745,794; 5,754,587; 5,762,516; 5,763,863; 5,767,500; 5,789,728; 5,808,287; 5,811,785; 5,811,787; 5,815,811; 5,821,519; 5,821,520; 5,823,812; 5,828,050; 5,850,078; 5,861,615; 5,874,720; 5,875,415; D305,885; D341,584; D344,501; D359,483; D362,453; D363,700; D363,918; D370,478; D383,124; D391,250; D405,077; D406,581. Invention No. 55,358; 62,539; 69,060; 69,187 (Taiwan); No. 1,601,796; 1,907,875; 1,955,269 (Japan). European Patent 367,299; 414,281; 367,300; 367,298; UK 2,072,832; France 81/03938; Italy 1,138,713. rev. 4/99


Scanning Made Easy
The LS 3603 features Symbol Technologies’ patented “fuzzy logic” technology. This innovation provides artificial intelligence that compensates for poor quality bar codes and gives the LS 3603 the best first-time read rate anywhere.
This scanner successfully reads most code symbologies, densities, and colors, produced by a wide range of printing techniques. See the LS 3603 Decode Zone on page 1-11.
With a simple cable change, the LS 3603 is compatible with:
- IBM 4683/4, 4693/4 series of terminals.
- All leading OCIA terminals, including NCR, Nixdorf, and ICL.
- Terminals using an XT, AT or PS/2-style keyboard. (When used as a
keyboard wedge, all scanned data is entered into your terminal in the form of keystrokes. No software changes to your host system are necessary.)
- Popular OCR terminals, such as Fujitsu and ICL.
The LS 3603 scans automatically at the rate of 36 scans per second. For decode capability, see Technical Specifications beginning on page 1-17

Remove the scanner from its packing and inspect it for damage. If the scanner was damaged in transit, call the Symbol Support Center at one of the telephone numbers listed on page 1-15. KEEP THE PACKING. It is the approved shipping container and should be used if you ever need to return your equipment for servicing.
Different cables are required for different hosts. To change the scanner cable:
Three power options are available:
Available power options are host dependent.
With some terminal types, the LS 3603 is unable to answer host terminal polls until the appropriate host type is selected. This may result in an error message generated by the host. To correct this situation, select the proper parameter set and initialize the host terminal. See Chapter 2 for more information.

For external power operation with single-piece cable

For direct host power operation:
*Coil cables that terminate in a 25-pin D-type connector have a power receptacle on the side of the connector assembly.
User’s Guide

For battery operation:


For external power operation:
Plug the scanner directly into the scanner input port of the host device.
User’s Guide


OCIA, OCR, IBM 4683, Keyboard Wedges
See the instructions packed with the appropriate Synapse cable.

Make sure connections are secure.
Aim the scanner away from you and press the trigger. When you press the trigger, the scanning beam is energized for approximately 3.0 seconds (default).
Make sure the symbol you want to scan is within the scanning range. See the LS 3603 Decode Zone diagram on page 1-11.
Aim and press the trigger.
The scan beam and red SCAN LED will light for about 3.0 seconds, or until a successful decode.
The scanner has read the symbol when:
The DECODE LED stays lit until the next trigger pull, unless Low Power Mode is selected. In this case, the DECODE LED is extinguished following the decode beep.
User’s Guide

Hold at an Angle
Do not hold the scanner directly over the bar code. In this position, light can bounce back into the scanner's exit window and prevent a successful decode. Problems
The beeper in the unit provides a variety of messages. See Beeper Indications beginning on page 2-19 Programming the System
An LS 3603 is programmed by scanning sequences of bar codes; consult Chapter 2.

The LS 3603 can be used as a fixed-mount scanner with the Scanstand Plus or IntelliStand model stands.
The Scanstand Plus may be used for all host interfaces except wand emulation with Norand terminals. Place the LS 3603 in the Scanstand Plus with the nose pointing toward the target bar code, and pull the trigger. The scanner will operate in a continuous-on mode, decoding any bar code placed over the target bar code. The LS 3603 reads the target bar code between decode
attempts to prevent accidental double reads.
To enter continuous-on mode, pull the trigger once with the scanner in the Scanstand Plus.
To exit continuous-on mode, pull the trigger once while the scanner is still in the Scanstand Plus.
The IntelliStand can be used in a number of different mounting arrangements. Place the LS 3603 in the stand, and it automatically turns on in a blinking, hands-free mode. Any symbol passed over the red scan line will be decoded. To conserve power, after a short period of time of non-use, the scanner will operate in a reduced power mode. See the IntelliStand Quick Reference Guide for full details.
User’s Guide

When using the LS 3603 with a battery box, you can use either an alkaline battery (recommended), or a nickel-cadmium rechargeable battery. Low battery power is signaled by four short, high tone beeps, coupled with scanning interruptions. If this occurs, change or recharge the battery as soon as possible.


User’s Guide

Cleaning the exit window is the only maintenance required.

What If...
You Should
You Should
You Should
User’s Guide

If you have a problem, contact the Symbol Support Center at the telephone number on page 1-15.
Before calling, have the model number and several of your bar code symbols at hand.
Call the Support Center from a phone near the scanning equipment so that the service person can try to talk you through your problem. If the equipment is found to be working properly and the problem is symbol readability, Support will request samples of your bar codes for analysis at our plant.
If your problem cannot be solved over the phone, you may need to return your equipment for servicing. If that is necessary, you will be given specific directions.

In the U.S.A., for service information, warranty information or technical assistance call:
If you purchased your Symbol product from a Symbol Business Partner, contact that Business Partner for service.
Europe
Wokingham, England European Headquarters 01734-771-222 (Inside UK) +44-1734-771222 (Outside UK)
Asia
Singapore Symbol Technologies Asia, Inc. 337-6588 (Inside Singapore) +65-337-6588 (Outside Singapore)
User’s Guide

LS 3603 scanners are sent as a package with required accessories, listed in the Product Ordering Guide. Optional accessories are available at extra cost.
Optional accessories, listed in the Product Ordering Guide, include various stands and holders, which are supplied at extra cost. Additional units of standard accessories may also be purchased at extra cost.

ITEM DESCRIPTION
4.8 (min) to 14.0 VDC (max) 150 mA @ 5V typical 150 mA @ 5V typical 150 mA @ 5V typical
Decode Capability The LS 3603 can be programmed to decode the following code types: UPC/EAN, Code 39, Code 39 Full ASCII, Codabar, Interleaved 2 of 5, Code 128, EAN 128, Discrete 2 of 5, Code 93, and MSI/Plessey. Set code length(s) for any 2 of 5 code type. The LS 3603 can autodiscriminate between all of the above code types except for Code 39 and Code 39 Full ASCII. Transmission of decoded information will depend on the capabilities of the attached terminal.
Beeper Operation User-selectable: Enabled, Disabled.
Scan Repetition Rate 36 (± 3) scans/sec (bidirectional)
Roll (Skew) Tolerance ± 10° from normal
Pitch ± 50° from normal
Yaw ± 60° from normal
Decode Depth of Field See Decode Zone
Print Contrast Minimum 25% absolute dark/light differential, measured at 675 nm.
200 ft. candles 2153 lux 8000 ft. candles 86112 lux (@8 in. (20 cm) on low density bar codes)

ITEM DESCRIPTION
Operating Temperature -22° to 122°F -30° to 50°C
Storage Temperature -40° to 140°F -40° to 60°C
Humidity 5% to 95% (non-condensing)
Coil Cable Length 9-12 ft. 274-365 cm (depending on host)
Durability 6-ft. drop to concrete 1.8 m
6.3 in. 16 cm 5 in. 12.7 cm 2.8 in. 7.1 cm
Laser Classifications CDRH Class II IEC 825 Class 2
*For direct host power connection, make sure the host terminal supplies sufficient power for the specified operation. Symbol is not responsible for damage to host equipment or system mis-operation due to an insufficient power condition.
Dimensions · Height Length Width

PIN RS-232 Wand Synapse
1 Not Used Not Used Not Used
2 VBAT 4.8-14.0V VBAT 4.8-14.0V VBAT 4.8-14.0V
3 Ground Ground Ground
4 RTS Output RTS Output Not Used
5 RxD Input Not Used Not Used
6 Not Used Not Used ZIF_CLOCK
7 DTR Output Not Used Not Used
8 TxD Output DBP Output Not Used
9 CTS Input CTS Input Not Used
10 Not Used Not Used ZIF_DATA
User’s Guide



Overview
Before programming, follow the instructions beginning on page 1-2
The LS 3603 is programmed by scanning appropriate bar codes. The bar codes are arranged in RS-232C, Wand and Synapse sections. Not all of the available parameters necessarily apply to your specific host systems. If, for example, the selected host is a wand emulator, and you enable Baud Rate, the parameter will be ignored until such time as a host recognizing that parameter is selected.
You can program any parameter, regardless of the mode you're in. For example, if you are in the Wand mode, you can still program Synapse and RS-232C parameters. When you switch from one mode to another, stored parameters remain unchanged. That means you can switch back and forth between RS-232C, Wand and Synapse modes without having to re-program the scanner.
Consult the Parameter Descriptions section beginning on page 2-3 for explanations of parameter types. A table of features supported by each host type begins on page 2-17.
There are separate defaults for each mode, and one for All Defaults. If the default values suit your requirements, all you need to do is scan the appropriate Set Default bar code. Parameters other than default values can be set by scanning sequences of bar codes. Parameter Menus contain all the bar codes necessary to program the scanner for each parameter selection. Regardless of whether or not you change defaults, if you select RS-232C or Wand mode, you must then select a host type. If you are using a Synapse Smart Cable, the host type will automatically be selected for you when you plug in the cable.
Remember to look at the top of the page to see whether the bar codes apply to RS-232C, Wand or Synapse parameters.

In most cases you need only scan one bar code to set a specific parameter. For example, if you want to add Code 39 to the Wand parameters, simply scan the Add Code 39 bar code in the Wand Code Types section. The LS 3603 will issue a warble tone, signifying a successful parameter entry.
If you want to add or change prefixes and suffixes you will have to scan several bar codes. This procedure is described in Parameter Descriptions.
Don't worry if you make an error during a scanning sequence. Merely reenter the correct parameter.

Set Default Parameter 2-4 Host Interface Code 2-4 Code Types 2-4 Code Lengths 2-4 Code 39 Full ASCI 2-5 Decode Options
Baud Rate 2-10 Parity 2-10 Beep on BEL 2-10 Hardware Handshaking 2-10 Software Handshaking 2-13 Stop Bit Select 2-15 ASCII Data Format 2-15 Intercharacter Delay 2-15 Transmit Code ID Character 2-15 Transmit AIM ID Character 2-15 Power Mode 2-16 Scanstand/IntelliStand 2-16
UPC-E/UPC-A Check Digit 2-5 Convert UPC-E to UPC-A 2-5 EAN Zero Extend 2-5 Transmit No Decode Message 2-5 UPC/EAN Supplemental 2-6 Code 39 Check Digit 2-6 ITF-14/EAN-13 Conversion 2-6 MSI/Plessey Check Digit 2-6 MSI/Plessey Check Digit Alg. 2-6 Buffer Code 39 2-7 Beep After Good Decode 2-7 CLSI Editing 2-7 NOTIS Editing 2-7 UPC/EAN Security Level 2-8 Codabar Decode Redundancy 2-8 UPC-E/UPC-A Preamble 2-9 Data Transmission Formats 2-9 Prefix/Suffix Values 2-9 Laser On Time-out 2-9
Wand Bar Output 2-16 Variable Leading Margin 2-16 Convert All to Code 39 2-16
For a listing of corresponding bar codes, see page 3-1.
Programming · RS-232C Options · Wand Emulator Options

Scanning the SET ALL DEFAULTS bar code on page 3-3 returns all parameters to the values listed in the Default Table. (See page 2-29.)
Scan the bar code corresponding to your host type. You must select a host type when you first set up the scanner and whenever you change host types.
The bar code menu selections enable the scanner to decode any or all of the
following symbologies.
The scanner will autodiscriminate between all of the above symbologies, except for Code 39 and Code 39 Full ASCII.
Select one or two lengths for the Interleaved or Discrete 2 of 5 codes. Determine the number of characters represented in the Discrete 2 of 5 or Interleaved 2 of 5 bar codes by counting the number of printed (i.e., human readable) digits beneath the bar code. Set one or both lengths, one per scanning sequence. For D 2 of 5, LENGTH 1 may range from 02-55 and LENGTH 2 from 00-55. For I 2 of 5, LENGTH 1 may range from 02-54 and LENGTH 2 from 00-54.

The ASCII character set assigns a code to letters, punctuation marks, numerals, and most control keystrokes on the keyboard.
The first 32 codes are non-printable and are assigned to keyboard control characters such as BACKSPACE and RETURN. The other 96 are called printable codes because all but SPACE and DELETE produce visible characters. See the tables beginning on page 2-23
Code 39 Full ASCII interprets the bar code control character ($ + % /) preceding a Code 39 symbol and assigns an ASCII character value. For example, when Code 39 Full ASCII is enabled and a +B is scanned, it will be interpreted as b, %J as ?, and $H emulates the keystroke BACKSPACE. Scanning ABC$M will output the keystroke equivalent of ABC ENTER.
The LS 3603 will not autodiscriminate between Code 39 and Code 39 Full ASCII.
Select if decoded UPC symbols are transmitted with or without a check digit.
Use this parameter to convert UPC-E (zero suppressed) decoded data to UPC-A format before transmission. After conversion, data will follow UPC format and be affected by UPC-A programming selections (e.g., Preamble, Check Digit).
This parameter adds five leading zeros to decoded EAN-8 symbols to make them compatible in format to EAN-13 symbols.
This feature gives you the option to transmit “NR” when a symbol does not
decode. Prefixes and suffixes enabled will be appended around this message.
Programming

Select whether UPC/EAN is decoded with or without supplemental characters. Supplementals are additionally appended characters (2 or 5) according to specific code format conventions (e.g., UPC A+2, UPC E+2, EAN 8+2). If UPC/EAN with supplemental characters is selected, UPC/EAN symbols without supplemental characters won't be decoded. If UPC/EAN without supplemental characters is selected and the scanner is presented with a UPC/EAN plus supplemental symbol, the UPC/EAN will be decoded and the supplemental characters ignored. If autodiscrimination is chosen, the LS 3603 will, after additional processing to ensure a good decode, transmit either. (NOTE: In order to minimize the risk of invalid data transmission, it is recommended that you select whether to read or ignore supplemental characters.)
When enabled, this parameter checks the integrity of a Code 39 symbol to ensure it complies with the modulo 43 check digit algorithm.
If your terminal supports EAN-13, this feature converts a 14 character I 2 of 5 code into EAN-13, and transmits to the host as EAN-13. In order to accomplish this, the I 2 of 5 code must be enabled, one length (either LENGTH 1 or LENGTH 2) must be set to 14, the code must have a leading zero and a valid EAN-13 check digit.
One or two digits at the end of the bar code that check the integrity of the data. At least one check digit (default) is always required. Check digits are not transmitted with the data.
When the two MSI/Plessey check digits option is selected, an additional verification is required to ensure integrity. Either of two algorithms may be selected; Mod10 - Mod10 (default), or Mod11 - Mod10.

When you select the scan and store option, all Code 39 symbols having a leading space as a first character are temporarily buffered in the unit to be transmitted later. The leading space is not buffered.
Decode of a valid Code 39 symbol with no leading space causes transmission in sequence of all buffered data in a first-in first-out format, plus transmission of the “triggering” symbol. See page 2-21 for further details.
When the scan and transmit option is selected, decoded Code 39 symbols without leading spaces are transmitted without being stored in the buffer.
Scan and Store affects Code 39 decodes only. If you select scan and store, it is recommended that you configure the scanner to decode Code 39 symbology only.
Determine if the unit beeper will sound during normal scanning. Usually it is
desirable to operate the unit with the beeper enabled. In all cases, the beeper operates during parameter menu scanning and indicates error conditions. Beeper indications begin on page 2-19.
This parameter strips the start and stop characters, then inserts a space after the 1st, 5th, and 10th characters of a 14-character Codabar symbol. Symbol length does not include start and stop characters.
This option strips the start and stop characters from decoded Codabar symbols.
Programming

The LS 3603 offers four levels of decode security for UPC/EAN bar codes. Increasing levels of security are provided for decreasing levels of bar code quality. There is an inverse relationship between security and scanner aggressiveness, so be sure to choose only that level of security necessary for any given application.
When enabled, a Codabar symbol must be decoded in both directions before being accepted as a successful decode.

Three options are given for the lead-in characters of decoded UPC-A or UPC-E symbols transmitted to the host device. Select one preamble for UPC-A decodes and one for UPC-E decodes. These lead-in characters are considered part of the symbol itself. The three options are:
The system character is the digit printed to the extreme left of a UPC symbol. The country code for UPC is always zero, and it cannot be transmitted without the system character.
Select the desired scan data format from one of the following:
= Scanned bar code data as selected by the user
A prefix/suffix may be appended to scan data for use in data editing. These values are set by scanning a four digit number (i.e., four bar codes) that correspond to keycodes for various terminals. An ASCII table begins on page 2-23.
The maximum time the laser will remain on or decode processing will continue during a trigger pull. Programmable in .5 sec increments from 0.5 to 5.0 sec.
Programming

Baud rate is the number of bits of data transmitted per second. The scanner's baud rate setting must match the data rate setting of the host device. If not, data will not reach the host device or may reach it in distorted form.
A parity check bit is the most significant bit of each ASCII coded character. If you select ODD parity, the parity bit will have a value 0 or 1, based on data, to ensure that an odd number of 1 bits are contained in the coded character.
If you select EVEN parity, the parity bit will have a value 0 or 1, to ensure that an even number of 1 bits are contained in the coded character. Select MARK parity and the parity bit will always be 1. Select SPACE parity and the parity bit will always be 0. Select the parity type according to host device requirements.
When this parameter is enabled, the scanner will issue a beep when a character is detected on the RS-232C serial line. is issued to gain a user’s attention to indicate an illegal entry or other important event. When the scanner is configured for low power operation, it will not respond to BEL characters in between decode attempts.
Hardware handshaking checks the readiness of the receiving device before data is transmitted. If the receiving device is periodically occupied with other tasks, hardware handshaking is needed to prevent loss of transmitted data. Hardware handshaking may not be used in conjunction with software hand- shaking. Refer to the flow chart on the following page.
RS-232C communications are designed to operate either with or without hardware handshaking lines, RTS, Request to Send, and CTS, Clear to Send.

Hardware Handshaking
If RTS/CTS handshaking is selected, scan data is transmitted with the following sequence: (Note that the DTR signal is hard wired active.)
During the transmission of data, the CTS line should be asserted.
Programming



Software Handshaking
This parameter controls the data transmission process. It may be used instead of, but not in conjunction with, hardware handshaking.
The scanner provides five software handshaking options, listed below. Refer to the flow chart on the following page.
The ACK/NAK option checks the result of a transmission. The scanner expects one of the following host responses after a data transmission:
- Acknowledges a valid and successful transmission.
- Indicates a problem with the transmission.
Whenever a is received, the unit retransmits the same data and awaits an ACK/NAK response. After three unsuccessful attempts to transmit the same data, the scanner aborts any further communication attempts on that message. Transmission error is indicated by the unit sounding 4 short beeps.
The ENQ option needs the host to request data before it is transmitted to the host. This ensures that data transmission occurs only when the host is ready to receive.
When you select the ENQ option, the scanner waits for an ENQ, Enquire character, from the host before it transmits data; otherwise the unit transmits data without waiting for an ENQ character from the host. With ENQ enabled, the scanner must receive an ENQ from the host within a 2 second period after the last activity or 4 short beeps are sounded to indicate a transmission error; the unit is now ready to scan again.
This combines both handshaking options.
Programming

Software Handshaking
When enabled, the scanner assumes an XON for the first transmission, and transmits scanned data until an XOFF is received. Transmission continues when an XON character is received. This option is automatically disabled when the unit is in Low Power mode.


Stop Bit Select
The stop bit(s) at the end of each transmitted character marks the end of transmission of one character and prepares the receiving device for the next character in the serial data stream. The number of stop bits (one or two) selected depends on the number the receiving terminal is programmed to accommodate. Set the number of stop bits to match host device requirements.
When enabled, this parameter transmits data in an 8-bit ASCII format. This allows the scanner to interface with devices requiring that protocol. The
default is 7-bit ASCII.
Select the intercharacter delay option matching host device requirements. The intercharacter delay gives the host system time to service its receiver and perform other tasks between characters. Select from no delay to a 99 msec delay between the transmission of each character.
A code ID character identifies the code type of a scanned bar code. This may be useful when the scanner is decoding more than one code type. If a prefix is selected, the code ID character is sent after the prefix. Code ID characters are: A = UPC-A, UPC-E, EAN-13, or EAN-8; B = Code 39; C = Codabar; D = Code 128; E = Code 93; F = Interleaved 2 of 5; G = Discrete 2 of 5; K = EAN 128; J = MSI Plessey.
Enabling this parameter, with the Transmit Code ID Character parameter enabled allows you to send the AIM code identifier in lieu of the Symbol identifiers listed above. The identifier will be sent as a three character prefix, in accordance with AIM specifications for symbology identifiers. See AIM’s Guidelines on Symbology Identifiers for full details.
Programming

This parameter determines whether or not power remains on after a decode attempt. When in low power mode, the scanner powers down after each decode attempt. When in continuous power mode, power remains on after each decode attempt. To ensure the integrity and proper operation of this product, it is recommended that the low power mode be set for RS-232C and Wand modes, and continuous power mode for Synapse mode.
Scanstand/IntelliStand operation can be programmed to shut down if no bar code is detected within the specified time. Duration is programmable in 15 minute increments from 15 minutes to 90 minutes.
The polarity of the wand emulator output is set automatically when the Wand Host type is selected. This parameter can be used to change the default polarity setting to match the type of signal (bar = logic high, or bar = logic low) expected by the receiving system
This parameter allows the selection of a variable leading margin, ranging from 80 msec to 200 msec, in 10 msec increments.
This parameter converts the output of all data to Code 39 format. Any coded character not in the Code 39 character set is replaced by a Code 39 blank.

DECODE PARAMETERS RS-232C Wand Synapse
Add Codes to be Decoded X X X
Bar High/ Bar Low X
Beep After Good Decode X X X
Beep on BEL X
Code 39 Buffering X X
Code 39 Check Digit X X
Convert All to Code 39 X
Convert UPC-E to A X X
D 2 of 5 Lengths X X X
Data Transmission Formats X X
Decode Redundancy for Codabar X X X
EAN Zero Extend X X
Host Interface Select X X X
I 2 of 5 Lengths X X X
ITF-14/EAN-13 Conversion X X
Laser On Time-out X X X
MSI Plessey 2 Check Digit Alg. X X X
Number of Stop Bits X
Power Mode X X X

DECODE PARAMETERS RS-232C Wand Synapse
Scanstand/Intellistand X X X
Transmit AIM ID Character X X
Transmit Code ID Character X X
Transmit MSI Check Digit X X
Transmit No Decode Message X X
Transmit UPC-A Check Digit X X
Transmit UPC-E Check Digit X X
UPC/EAN Security Level X X X
UPC/EAN Supplemental X X X
UPC-E/UPC-A Preamble X X
Wand Bar Output X
Wand Leading Margin X
Software Handshaking X

1 Beep - short high tone A bar code symbol was decoded (if decode beeper is enabled).
4 Beeps - short high tone Low battery power.
4 Beeps - long low tone A format or transmission error has been detected in a scanned symbol. The data is ignored. This will occur if a unit is not properly configured. Check option settings.
1 Beep - short high tone Correct entry scanned or correct menu sequence performed.
1 Beep - lo/hi tone Input error, incorrect bar code or “Cancel” scanned, wrong entry, incorrect bar code programming sequence; remain in program mode.
1 Beep - hi/lo tone Keyboard parameter selected. Enter value using bar code keypad.
1 Beep - hi/lo/hi/lo tone Successful program exit with change in the parameter setting.

1 Beep - hi/lo tone New Code 39 data was entered into the buffer.
3 Beeps - long high tone Code 39 buffer is full.
1 Beep - lo/hi/lo tone The buffer was erased, or there was an attempt to transmit an empty buffer. When the Code 39 buffer was empty, the scanner read a command to clear or to transmit a Code 39 buffer.
2 Beeps - long high tone Error in data transmission.
1Beep - lo/hi tone A successful transmission of buffered data.
Code 39 Buffering · Beeper Sequence Indication

While there is data in the transmission buffer, deleting Code 39 buffering capability via the parameter menu is not allowed. The buffer will hold 250 bytes of information.
To allow disabling of Code 39 buffering, first force the buffer transmission (see Transmit Buffer) or clear the buffer.
To buffer data, Code 39 buffering must be enabled, and a symbol must be read with a space immediately following the start pattern.
To clear the transmission buffer, read a symbol which contains only a start
character, a dash (minus), and a stop character.
Programming

To transmit the buffer, read a symbol containing either the first or second condition:
If the symbol just read will result in an overflow of the transmission buffer:
If the symbol just read was the transmit buffer symbol and the Code 39 buffer is empty:

ASCII
Code 39 Encode Char.
Code 39 Encode Char
1001 $A CTRL A 1025 $Y CTRL Y
1002 $B CTRL B 1026 $Z CTRL Z
1003 $C CTRL C 1027 %A CTRL [
1004 $D CTRL D 1028 %B CTRL \
1005 $E CTRL E 1029 %C CTRL ]
1006 $F CTRL F 1030 %D CTRL 6
1007 $G CTRL G 1031 %E CTRL -
1008 $H CTRL H 1032 Space Space
1010 $J CTRL J 1034 /B ‘
1011 $K CTRL K 1035 /C #
1012 $L CTRL L 1036 /D $
1013 $M CTRL M 1037 /E %
1014 $N CTRL N 1038 /F &
1015 $O CTRL O 1039 /G ‘
1016 $P CTRL P 1040 /H (
1017 $Q CTRL Q 1041 /I )
1018 $R CTRL R 1042 /J *
1019 $S CTRL S 1043 /K +
1020 $T CTRL T 1044 /L ,
1021 $U CTRL U 1045 - -
1022 $V CTRL V 1046 . .

ASCII
Code 39 Encode Char.
Code 39 Encode Char
1049 1 1 1074 J J
1050 2 2 1075 K K
1051 3 3 1076 L L
1052 4 4 1077 M M
1053 5 5 1078 N N
1054 6 6 1079 O O
1055 7 7 1080 P P
1056 8 8 1081 Q Q
1057 9 9 1082 R R
1058 /Z : 1083 S S
1059 %F ; 1084 T T
1060 %G < 1085 U U
1061 %H = 1086 V V
1062 %I > 1087 W W
1063 %J ? 1088 X X
1064 %V @ 1089 Y Y
1065 A A 1090 Z Z
1066 B B 1091 %K [
1067 C C 1092 %L \
1068 D D 1093 %M ]
1069 E E 1094 %N ^
1070 F F 1095 %O _
1071 G G 1096 %W ‘
1072 H H 1097 +A a

ASCII
Code 39 Encode Char.
Code 39 Encode Char
1098 +B b 1113 +Q q
1099 +C c 1114 +R r
1100 +D d 1115 +S s
1101 +E e 1116 +T t
1102 +F f 1117 +U u
1103 +G g 1118 +V v
1104 +H h 1119 +W w
1105 +I i 1120 +X x
1106 +J j 1121 +Y y
1107 +K k 1122 +Z z
1108 +L l 1123 %P {
1109 +M m 1124 %Q |
1110 +N n 1125 %R }
1111 +O o 1126 %S ~
1112 +P p 1127 Undefined

ALT Keys Keystroke ALT Keys Keystroke ALT Keys Keystroke
2064 ALT 2 2075 ALT K 2086 ALT V
2065 ALT A 2076 ALT L 2087 ALT W
2066 ALT B 2077 ALT M 2088 ALT X
2067 ALT C 2078 ALT N 2089 ALT Y
2068 ALT D 2079 ALT O 2090 ALT Z
2069 ALT E 2080 ALT P 2091 ALT [
2070 ALT F 2081 ALT Q 2092 ALT \
2071 ALT G 2082 ALT R 2093 ALT ]
2072 ALT H 2083 ALT S 2094 ALT 6
2073 ALT I 2084 ALT T 2095 ALT -
Misc. Key Keystroke Misc. Key Keystroke Misc. Key Keystroke
3002 PA 2 3010 CMD 8 3018 1/2
3003 CMD 1 3011 CMD 9 3019 ¶
3004 CMD 2 3012 CMD 10 3020 §
3005 CMD 3 3013 ¥ 3021 |
3006 CMD 4 3014 £ 3022 0/00
3007 CMD 5 3015 ¤
3008 CMD 6 3016 ¬

PF Keys Keystroke PF Keys Keystroke PF Keys Keystroke
4001 PF 1 4009 PF 9 4017 PF 17
4002 PF 2 4010 PF 10 4018 PF 18
4003 PF 3 4011 PF 11 4019 PF 19
4004 PF 4 4012 PF 12 4020 PF 20
4005 PF 5 4013 PF 13 4021 PF 21
4006 PF 6 4014 PF 14 4022 PF 22
4007 PF 7 4015 PF 15 4023 PF 23
4008 PF 8 4016 PF 16 4024 PF 24
F Keys Keystroke F Keys Keystroke F Keys Keystroke
5001 F 1 5014 F 14 5027 F 27
5002 F 2 5015 F 15 5028 F 28
5003 F 3 5016 F 16 5029 F 29
5004 F 4 5017 F 17 5030 F 30
5005 F 5 5018 F 18 5031 F 31
5006 F 6 5019 F 19 5032 F 32
5007 F 7 5020 F 20 5033 F 33
5008 F 8 5021 F 21 5034 F 34
5009 F 9 5022 F 22 5035 F 35
5010 F 10 5023 F 23 5036 F 36
5011 F 11 5024 F 24 5037 F 37
5012 F 12 5025 F 25 5038 F 38
5013 F 13 5026 F 26 5039 F 39
Programming

6042 * 6049 1 6056 8
6043 + 6050 2 6057 9
6044 Undefined 6051 3 6058 Enter
6045 - 6062 4 6059 Num Lock
6046 . 6063 5 6060 00
6047 / 6064 6
6048 0 6065 7
7001 Break 7008 Backspace 7015 Up Arrow
7002 Delete 7009 Tab 7016 Dn Arrow
7003 Pg Up 7010 Print Screen 7017 Left Arrow
7004 End 7011 Insert 7018 Right Arrow
7005 Pg Dn 7012 Home 7019 Back Tab
7006 Pause 7013 Enter
7007 Scroll Lock 7014 Escape

I 2 of 5 D 2 of 5
Transmit UPC-A Check Digit Transmit UPC-E Check Digit Convert UPC-E to UPC-A EAN Zero Extend Transmit No Decode Message Decode UPC/EAN Supplemental ITF-14/EAN-13 Conversion Transmit Code 39 Check Digit MSI Plessey Check Digit MSI Plessey 2 Check Digit Algorithm Buffer Code 39 Beep After Good Decode CLSI Editing NOTIS Editing UPC/EAN Security Level Codabar Decode Redundancy
Enabled Enabled Disabled One Mod 10 - Mod 10 Disabled Enabled Disabled Disabled 0 Disabled
UPC-A Preamble System Character
UPC-E Preamble System Character
Suffix Only N/A Data As Is
Prefix/Suffix Values 7013 ( for wedges, for serial devices)

Laser On Time-out 3 Sec
Power Mode Low Power (Continuous for Synapse only)
Scanstand/Intellistand Time-out 60 minutes
Baud Rate Parity Beep on BEL Hardware Handshaking Software Handshaking Stop Bit Select ASCII Data Format Terminal Specific Defaults
9600 Even Disabled None None Two 7 Bit Standard RS-232C Defaults
Transmit Code ID Character Disabled
Transmit AIM ID Character Disabled
Wand Emulator Bar Output Bar High
Variable Leading Margin 80 msec.
Convert All to Code 39 Disabled
Parameter Default · RS-232C Options · Intercharacter Delay 0

Three RS-232C hosts are set up with their own fixed format options. Selecting the ICL, Fujitsu or Nixdorf RS-232C terminal will set the defaults listed below.
Parameter Standard ICL FUJITSU NIXDORF
Transmit Code ID No Yes Yes Yes
Data Transmission Format Data as is Data/Suffix Data/Suffix Data/Suffix
Suffix CR/LF (7013) CR (1013) CR (1013) CR (1013)
Baud Rate 9600
Parity Even Even None Odd
Hardware Handshaking None
Software Handshaking None
Stop Bit Select Two One One One
ASCII Format 7-Bit 8-Bit 8-Bit 8-Bit
Beep On <BEL> Disabled
RTS Line State Low High Low Low
RS-232C UPC-A Code ID “A”
RS-232C UPC-E Code ID “A” “E” “E” “C0”
RS-232C EAN-8 Code ID “A” “FF” “FF” “B”
RS-232C EAN-13 Code ID “A” “F” “F” “A”
RS-232C Code 39 Code ID “B” “C” None “M”
RS-232C Codabar Code ID “C” “N” None “N”
RS-232C Code 128 Code ID “D” None None “K”
RS-232C I 2 of 5 Code ID “F” “I” None “I”
RS-232C MSI/Plessey Code ID “J” None None “O”
Programming



Set Default Parameter page 3-3 Host Interface Select page 3-4
Fixed Format Options page 3-5 Code Types page 3-6 Code 2 of 5 Lengths page 3-9 Decode Options page 3-11 UPC-A Preamble page 3-17 UPC-E Preamble page 3-18 Intercharacter Delay page 3-19 Data Transmission Formats page 3-21 Prefix/Suffix Values page 3-22 Transmit Code ID Character page 3-24 Transmit AIM ID Character page 3-25 Laser On Time-out page 3-26 Scanstand/IntelliStand Time-out page 3-28 Baud Rate page 3-29 Parity page 3-30 Beep on BEL page 3-31 Hardware Handshaking page 3-32 Software Handshaking page 3-33 Stop Bit Select page 3-34 ASCII Format page 3-35 Power Mode page 3-36

Wand Host Interface page 3-37 Code Types page 3-38 Code 2 of 5 Lengths page 3-41 Decode Options page 3-43 Laser On Time-out page 3-45 Scanstand/IntelliStand Time-out page 3-47 Power Mode page 3-48 Wand Emulator Bar Output page 3-49 Variable Leading Margin page 3-50 Convert All To Code 39 page 3-52
Code Types page 3-53 Code 2 of 5 Lengths page 3-56 Decode Options page 3-58 UPC-A Preamble page 3-64 UPC-E Preamble page 3-65 Data Transmission Formats page 3-66 Prefix/Suffix Values page 3-67 Transmit Code ID Character page 3-69 Transmit AIM ID Character page 3-70 Laser On Time-out page 3-71 Scanstand/IntelliStand Time-out page 3-73 Power Mode page 3-74
For an explanation of these parameters, see page 2-3.

Refer to the Default Table on page 2-29
To set defaults for any or all host types, scan the appropriate bar code below. Then select a specific host interface on the next page.
SET WAND DEFAULTS
SET SYNAPSE DEFAULTS
SET ALL DEFAULTS
Parameter Menus

To select a host interface, scan the appropriate bar code below.
SET WAND HOST
SET SYNAPSE HOST

Select fixed format options for the terminals listed below.
SET FUJITSU RS-232C FORMATS
SET ICL RS-232C FORMATS
Parameter Menus

Add or delete specific code types by scanning the appropriate bar code(s).
DELETE UPC-A ADD UPC-A
DELETE UPC-E ADD UPC-E
DELETE CODABAR ADD CODABAR

DELETE EAN-13 ADD EAN-13
DELETE I 2 OF 5 ADD I 2 OF 5
DELETE D 2 OF 5 ADD D 2 OF 5
Parameter Menus

DELETE MSI/Plessey ADD MSI/Plessey
DELETE EAN 128 ADD EAN 128

To set the lengths for each code type:
D 2 of 5 LENGTH 1
D 2 of 5 LENGTH 2
(RANGE 00-55)
I 2 of 5 LENGTH 1
I 2 of 5 LENGTH 2
(RANGE 00-54)
Parameter Menus


DO NOT TRANSMIT UPC-A CHECK DIGIT
CHECK DIGIT
TRANSMIT UPC-E
DO NOT TRANSMIT UPC-E CHECK DIGIT
CHECK DIGIT
DO NOT CONVERT UPC-E TO UPC-A
CONVERT UPC-E TO UPC-A
Parameter Menus

IGNORE UPC/EAN WITH SUPPLEMENTALS
AUTODISCRIMINATE UPC/EAN
WITH SUPPLEMENTALS
ENABLE EAN ZERO EXTEND DISABLE EAN ZERO EXTEND
TRANSMIT “NO DECODE”
DO NOT TRANSMIT “NO DECODE” MESSAGE
MESSAGE

ENABLE NOTIS EDITING DISABLE NOTIS EDITING
ENABLE CODE 39
DISABLE CODE 39
FULL ASCII
FULL ASCII
VERIFTY CODE 39
DO NOT VERIFY CODE 39
CHECK DIGIT
CHECK DIGIT
Parameter Menus

ITF-14/EAN-13 CONVERSION
ENABLED
DISABLED
BEEP AFTER GOOD DECODE DO NOT BEEP AFTER GOOD DECODE

UPC/EAN SECURITY LEVEL 1
UPC/EAN SECURITY LEVEL 2
UPC/EAN SECURITY LEVEL 3
Parameter Menus

CHECK DIGITS
MSI 2 CHECK DIGITS
MSI 2 CHECK DIGITS
MOD 10 - MOD 10
MOD 11 - MOD 10
ENABLE CODABAR DECODE REDUNDANCY
DISABLE CODABAR DECODE REDUNDANCY
ENABLE 1 MSI/Plessey · ENABLE 2 MSI/Plessey

Select one option for UPC-A preamble by scanning the appropriate bar code.
SYSTEM CHARACTER
SYSTEM CHARACTER
& COUNTRY CODE
Parameter Menus

Select one option for UPC-E preamble by scanning the appropriate bar code.
SYSTEM CHARACTER
SYSTEM CHARACTER
& COUNTRY CODE

To set a host communications intercharacter delay:
Parameter Menus


Scan the option you wish to set.
<PREFIX> <DATA>
<DATA> <SUFFIX>
<PREFIX> <DATA> <SUFFIX>
Parameter Menus

To set a PREFIX/SUFFIX value:
SUFFIX

Parameter Menus

Select whether to enable or disable this parameter.
DO NOT TRANSMIT CODE ID CHARACTER

Select whether to enable or disable this parameter.
DO NOT TRANSMIT AIM ID CHARACTER
Parameter Menus

To select a laser on time-out, scan the bar code below or on the next page corresponding to the desired time.
1.5 SECONDS 2.0 SECONDS
2.5 SECONDS 3.0 SECONDS

4.5 SECONDS 5.0 SECONDS
Parameter Menus

To select a Scanstand/IntelliStand time-out, scan the bar code below corresponding to the desired time-out.
60 MINUTES
30 MINUTES
75 MINUTES
45 MINUTES
90 MINUTES

Set the baud rate for RS-232C transmission.
Parameter Menus

Set the type of parity for RS-232C transmission.
MARK SPACE
NONE

Select whether or not enable this parameter.
DO NOT BEEP ON BEL
Parameter Menus

Select the type of RS-232C hardware handshaking protocol.
RTS/CTS

Select the type of RS-232C software handshaking protocol.
ACK/NAK
ENQ ONLY
XON/XOFF
Parameter Menus · ACK/NAK with ENQ

Select the desired number of stop bits for RS-232C communications.
2 STOP BITS

Select either 7-bit or 8-bit ASCII format for RS-232C communications.
8-BIT
Parameter Menus

Select whether the laser remains on continuously, or turns off after a decode attempt (Low Power).
LOW POWER

Select the appropriate host by scanning one of the bar codes below.
SYMBOL PORTABLE TERMINAL
NORAND TERMINAL
Parameter Menus

Add or delete specific code types by scanning the appropriate bar code(s).
DELETE UPC-A ADD UPC-A
DELETE UPC-E ADD UPC-E
DELETE CODABAR ADD CODABAR

DELETE EAN-13 ADD EAN-13
DELETE I 2 OF 5 ADD I 2 OF 5
DELETE D 2 OF 5 ADD D 2 OF 5
Parameter Menus

DELETE MSI/Plessey ADD MSI/Plessey
DELETE EAN 128 ADD EAN 128

To set the lengths for each code type:


D 2 of 5 LENGTH 1
D 2 of 5 LENGTH 2
(RANGE 00-55)


I 2 of 5 LENGTH 1
I 2 of 5 LENGTH 2
(RANGE 00-55)
Parameter Menus


IGNORE UPC/EAN WITH SUPPLEMENTALS
AUTODISCRIMINATE UPC/EAN
WITH SUPPLEMENTALS
BEEP AFTER GOOD DECODE DO NOT BEEP AFTER GOOD DECODE
CHECK DIGITS
Parameter Menus · ENABLE 1 MSI/Plessey · ENABLE 2 MSI/Plessey

MSI 2 CHECK DIGITS
MOD 10 - MOD 10
MOD 11 - MOD 10
ENABLE CODABAR DECODE REDUNDANCY
DISABLE CODABAR DECODE REDUNDANCY
UPC/EAN SECURITY LEVEL 0 UPC/EAN SECURITY LEVEL 1
UPC/EAN SECURITY LEVEL 2 UPC/EAN SECURITY LEVEL 3

To select a laser on time-out, scan the bar code below or on the next page corresponding to the desired time.
1.5 SECONDS 2.0 SECONDS
2.5 SECONDS 3.0 SECONDS
Parameter Menus

4.5 SECONDS 5.0 SECONDS

To select a Scanstand/IntelliStand time-out, scan the bar code below corresponding to the desired time-out.
60 MINUTES
30 MINUTES
75 MINUTES
45 MINUTES
90 MINUTES
Parameter Menus

Select whether the laser remains on continuously, or turns off after a decode attempt (Low Power).
LOW POWER

Select the option that matches your host system.
BAR LOW
Parameter Menus

Select a variable leading margin.


Select whether or not to convert the decoded output to Code 39.
DO NOT CONVERT ALL TO CODE 39

Add or delete specific code types by scanning the appropriate bar code(s).
DELETE UPC-A ADD UPC-A
DELETE UPC-E ADD UPC-E
DELETE CODABAR ADD CODABAR
Parameter Menus

DELETE EAN-13 ADD EAN-13
DELETE I 2 OF 5 ADD I 2 OF 5
DELETE D 2 OF 5 ADD D 2 OF 5

DELETE MSI/Plessey ADD MSI/Plessey
DELETE EAN 128 ADD EAN 128
Parameter Menus

To set the lengths for each code type:


D 2 of 5 LENGTH 1
D 2 of 5 LENGTH 2
(RANGE 00-55)


I 2 of 5 LENGTH 2
I 2 of 5 LENGTH 1
(RANGE 02-55)

Parameter Menus

DO NOT TRANSMIT UPC-A CHECK DIGIT
CHECK DIGIT
TRANSMIT UPC-E
DO NOT TRANSMIT UPC-E CHECK DIGIT
CHECK DIGIT
CONVERT UPC-E TO UPC-A
DO NOT CONVERT UPC-E TO UPC-A

AUTODISCRIMINATE UPC/EAN
WITH SUPPLEMENTALS
ENABLE EAN ZERO EXTEND DISABLE EAN ZERO EXTEND
TRANSMIT “NO DECODE”
DO NOT TRANSMIT “NO DECODE” MESSAGE
MESSAGE
Parameter Menus

ENABLE NOTIS EDITING DISABLE NOTIS EDITING
ENABLE CODE 39
DISABLE CODE 39
FULL ASCII
FULL ASCII
VERIFTY CODE 39
DO NOT VERIFY CODE 39
CHECK DIGIT
CHECK DIGIT

ITF-14/EAN-13 CONVERSION
ENABLED
DISABLED
BEEP AFTER GOOD DECODE DO NOT BEEP AFTER GOOD DECODE
Parameter Menus

UPC/EAN SECURITY LEVEL 2 UPC/EAN SECURITY LEVEL 3

CHECK DIGITS
MSI 2 CHECK DIGITS
MSI 2 CHECK DIGITS
MOD 10 - MOD 10
MOD 11 - MOD 10
ENABLE CODABAR DECODE REDUNDANCY
DISABLE CODABAR DECODE REDUNDANCY
Parameter Menus · ENABLE 1 MSI/Plessey · ENABLE 2 MSI/Plessey

Select one option for UPC-A preamble by scanning the appropriate bar code.
SYSTEM CHARACTER
SYSTEM CHARACTER
& COUNTRY CODE

Select one option for UPC-E preamble by scanning the appropriate bar code.
SYSTEM CHARACTER
SYSTEM CHARACTER
& COUNTRY CODE
Parameter Menus

Scan the option you wish to set.
<PREFIX> <DATA>
<DATA> <SUFFIX>
<PREFIX> <DATA> <SUFFIX>

To set a PREFIX/SUFFIX value:
SUFFIX
Parameter Menus


Select whether to enable or disable this parameter.
DO NOT TRANSMIT CODE ID CHARACTER
Parameter Menus

Select whether to enable or disable this parameter.
DO NOT TRANSMIT AIM ID CHARACTER

To select a laser on time-out, scan the bar code below or on the next page corresponding to the desired time.
1.5 SECONDS 2.0 SECONDS
2.5 SECONDS 3.0 SECONDS
Parameter Menus

4.5 SECONDS 5.0 SECONDS

To select a Scanstand/IntelliStand time-out, scan the bar code below corresponding to the desired time-out.
60 MINUTES
75 MINUTES
30 MINUTES
90 MINUTES
45 MINUTES
Parameter Menus

Select whether the laser remains on continuously, or turns off after a decode attempt (Low Power).
LOW POWER

ASCII - American Standard Code for Information Interchange. A 7 bit-plus- parity code representing 128 letters, numerals, punctuation marks, and control characters. It is a standard data transmission code in the U.S.
BIT - Binary digit. One bit is the basic unit of binary information. Generally, eight consecutive bits compose one byte of data. The pattern of 0 and 1 values within the byte determines its meaning.
BYTE - On an addressable boundary, eight adjacent binary digits (0 and 1) combined in a pattern to represent a specific character or numeric value. Bits are numbered from the right, 0 through 7, with bit 0 the low-order bit. One byte in memory can be used to store one ASCII character.
CDRH - Center for Devices and Radiological Health. A federal agency responsible for regulating laser product safety. This agency specifies various laser operation classes based on power output during operation.
CDRH CLASS I - This is the lowest power CDRH laser class. Class 1 lasers are safe when used in accordance with the user instructions. They are inherently safe (so that the maximum possible exposure level cannot be exceeded under any condition), or are safe by virtue of their engineering design.
CHECK DIGIT - A digit used to verify a correct symbol decode. The scanner inserts the decoded data into an arithmetic formula and checks that the resulting number matches the encoded check digit. Check digits are required for UPC but are optional for other symbologies. Using check digits decreases
the chance of substitution errors when a symbol is decoded.
CODABAR - A discrete self-checking code with a character set consisting of
digits 0 to 9 and six additional characters: (- $ : / , +).
CODE 128 - A high density symbology which allows the controller to encode all 128 ASCII characters without adding extra symbol elements.

CODE 3 OF 9 (CODE 39) - A versatile and widely used alphanumeric bar code symbology with a set of 43 character types, including all uppercase letters, numerals from 0 to 9, and 7 special characters (- . / + % $ and space). The code name is derived from the fact that 3 of 9 elements representing a character are wide, while the remaining 6 are narrow.
CODE 93 - An industrial symbology compatible with Code 39 but offering a full character ASCII set and a higher coding density than Code 39.
CONTINUOUS CODE - A bar code or symbol in which all spaces within the symbol are parts of characters. There are no intercharacter gaps in a continuous code. The absence of gaps allows for greater information density.
DECODE - To recognize a bar code symbology (e.g., UPC/EAN) and then analyze the content of the specific bar code scanned.
DECODE ALGORITHM - A decoding scheme that converts pulse widths into data representation of the letters or numbers encoded within a bar code symbol.
DISCRETE CODE - A bar code or symbol in which the spaces between characters (intercharacter gaps) are not part of the code.
DISCRETE 2 OF 5 - A binary bar code symbology representing each character by a group of five bars, two of which are wide. The location of wide bars in the group determines which character is encoded; spaces are insignificant. Only numeric characters (0 to 9) and START/STOP characters may be encoded.
EAN - European Article Number. This European/International version of the UPC provides its own coding format and symbology standards. Element dimensions are specified metrically. EAN is used primarily in retail.
HOST COMPUTER - A computer that serves other terminals in a network, providing such services as computation, database access, supervisory programs, and network control.
IEC - International Electrotechnical Commission. This international agency regulates laser safety by specifying various laser operation classes based on power output during operation.

IEC CLASS I (IEC 825 Class I) - This is the lowest power IEC laser classification. Conformity is ensured through a software restriction of 120 seconds of laser operation within any 1000 second window and an automatic laser shutdown if the scanner's oscillating mirror fails.
INTERCHARACTER GAP - The space between two adjacent bar code characters in a discrete code.
INTERLEAVED BAR CODE - A bar code in which characters are paired together, using bars to represents the first character and the intervening spaces to represent the second.
INTERLEAVED 2 OF 5 - A binary bar code symbology representing character pairs in groups of five bars and five interleaved spaces. Interleaving provides
for greater information density. The location of wide elements (bar/spaces) within each group determines which characters are encoded. This continuous code type uses no intercharacter spaces. Only numeric (0 to 9)
and START/STOP characters may be encoded.
LASER - An acronym for Light Amplification by Stimulated Emission of Radiation. The laser is an intense light source. Light from a laser is all the same frequency, unlike the output of an incandescent bulb. Laser light is typically coherent and has a high energy density.
LASER DIODE - A gallium-arsenide semiconductor type of laser connected to a power source to generate a laser beam. This laser type is a compact source of coherent light.
PARAMETER - A variable that can have different values assigned to it.
PROGRAMMING MODE - The state in which a scanner is configured for parameter values. See SCANNING MODE.
QUIET ZONE - A clear space, containing no dark marks, which precedes the start character of a bar code symbol and follows the stop character.
Glossary

SCANNER - An electronic device used to scan bar code symbols and produce a digitized pattern that corresponds to the bars and spaces of the symbol. Its three main components are:
SCANNING MODE - The scanner is energized, programmed, and ready to read a bar code.
SCANNING SEQUENCE - A method of programming or configuring parameters for a bar code reading system by scanning bar code menus.
SELF-CHECKING CODE - A symbology that uses a checking algorithm to detect encoding errors within the characters of a bar code symbol.
START/STOP CHARACTER - A pattern of bars and spaces that provides the scanner with start and stop reading instructions and scanning direction. The start and stop characters are normally to the left and right margins of a horizontal code.
SYMBOL - A scannable unit that encodes data within the conventions of a certain symbology, usually including start/stop characters, quiet zones, data characters, and check characters.
SYMBOLOGY - The structural rules and conventions for representing data within a particular bar code type (e.g. UPC/EAN, Code 39).
UPC - Universal Product Code. A relatively complex numeric symbology. Each character consists of two bars and two spaces, each of which can be any of four widths. The standard symbology for retail food packages in the United States.
Wat de op het display getoonde foutcodes betekenen en hoe u ze wist.
| Code | Betekenis | Oplossing | |
|---|---|---|---|
| RS-232C | . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 | p.5 |
Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.
Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.