Product Reference Guide
72-38495-03 · Revision B · December 2001

© 2001 by Symbol Technologies, Inc. All rights reserved.
No part of this publication may be reproduced or used in any form, or by any electrical or mechanical means, without permission in writing from Symbol. This includes electronic or mechanical means, such as photocopying, recording, or information storage and retrieval systems. The material in this manual is subject to change without notice.
The software is provided strictly on an “as is” basis. All software, including firmware, furnished to the user is on a licensed basis. Symbol grants to the user a non-transferable and non-exclusive license to use each software or firmware program delivered hereunder (licensed program). Except as noted below, such license may not be assigned, sublicensed, or otherwise transferred by the user without prior written consent of Symbol. No right to copy a licensed program in whole or in part is granted, except as permitted under copyright law. The user shall not modify, merge, or incorporate any form or portion of a licensed program with other program material, create a derivative work from a licensed program, or use a licensed program in a network without written permission from Symbol. The user agrees to maintain Symbol’s copyright notice on the licensed programs delivered hereunder, and to include the same on any authorized copies it makes, in whole or in part. The user agrees not to decompile, disassemble, decode, or reverse engineer any licensed program delivered to the user or any portion thereof.
Symbol reserves the right to make changes to any software or product to improve reliability, function, or design.
Symbol does not assume any product liability arising out of, or in connection with, the application or use of any product, circuit, or application described herein.
No license is granted, either expressly or by implication, estoppel, or otherwise under any Symbol Technologies, Inc., intellectual property rights. An implied license only exists for equipment, circuits, and subsystems contained in Symbol products.
Symbol, Spectrum One, and Spectrum24 are registered trademarks of Symbol Technologies, Inc. Other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies and are hereby acknowledged.
Symbol Technologies, Inc. One Symbol Plaza Holtsville, New York 11742-1300 http://www.symbol.com

Introduction ix Chapter Descriptions ix Notational Conventions ix Related Publications x Service Information x
Symbol Support Center xi Warranty xiii
Warranty Coverage and Procedure xiv General xiv
Introduction 1-1 Rechargeable Battery 1-2 The Cradle 1-2 Quick Startup Instructions 1-3 Commonly Used P470/P370 Programming Bar Code 1-4
Introduction 2-1 Unpacking 2-1 Setting Up the Cradle 2-1
Connecting to a Host 2-1 Wall Mounting 2-4 Pairing the Scanner with the Cradle 2-6 Optimizing RF Performance 2-7
Mounting 2-7 Coexistence in Spectrum24 Environments 2-7 Phaser-to-Phaser Co-Existence 2-8

Charging the Battery 2-8
Using the Cradle 2-9 Using the UBC 2000 2-9 Battery Charge 2-9
Introduction 3-1 Default Application 3-1
Initial Powerup 3-2 Scan and Transmit Application 3-2 Eliminating Repetitive Scanning 3-4 Communication Errors 3-5
RF Communication Errors 3-5 Host / Cradle Communication Errors 3-6 System Menu 3-7 123Scan 3-17 Suffix Values 3-18 Scanning 3-22
Scan the Entire Symbol 3-22 Hold at an Angle 3-23 Decode Zone 3-24 Keypad Operation 3-26 Troubleshooting 3-29
Introduction 4-1 Maintenance 4-1 Changing the Battery 4-1
Removing the Battery 4-2 Replacing the Battery 4-2 Charge Status LED Indications 4-3 Technical Specifications 4-4 Cradle Pin-outs 4-6 Beeper Indications / Default Application Error Codes 4-7
Introduction 5-1 Operational Parameters 5-1 Set Default Parameter 5-7 Communication Protocol 5-8
Scan & Transmit Application 5-8

Host Type 5-9
RS-232C Host Types 5-9 Host Response Timeout 5-12 RF Channel 5-13 RF Retries 5-13 Sleep Time 5-15 Decimal Separator 5-16 Key Click 5-17 Beeper Tone 5-18 Beeper Volume 5-19 Power Detect Beep 5-20 Beep After Good Decode 5-21 Laser On Time 5-22 Transmit “No Read” Message 5-23 Linear Code Type Security Level 5-24
Linear Security Level 1 5-24 Linear Security Level 2 5-24 Linear Security Level 3 5-25 Linear Security Level 4 5-25 Bi-directional Redundancy 5-26 Autodiscriminate Response Time 5-27 Enable/Disable UPC-E/UPC-A/UPC-E1 5-28 Enable/Disable EAN-8/EAN-13 5-29 Enable/Disable Bookland EAN 5-30 Decode UPC/EAN Supplementals 5-31 Decode UPC/EAN Supplemental Redundancy 5-32 Transmit UPC-A/UPC-E/UPC-E1 Check Digit 5-33 UPC-A Preamble 5-34 UPC-E Preamble 5-35 UPC-E1 Preamble 5-36 Convert UPC-E to UPC-A 5-37 Convert UPC-E1 to UPC-A 5-38 EAN-8 Zero Extend 5-39 Convert EAN-8 to EAN-13 Type 5-40 UPC/EAN Security Level 5-41
UPC/EAN Security Level 0 5-41 UPC/EAN Security Level 1 5-41 UPC/EAN Security Level 2 5-42 UPC/EAN Security Level 3 5-42 UPC/EAN Coupon Code 5-43 Enable/Disable Code 128 5-44 Enable/Disable UCC/EAN-128 5-45 Lengths for Code 128 5-45 Enable/Disable Code 39 5-46
Contents

Enable/Disable Trioptic Code 39 5-47 Set Lengths for Code 39 5-48 Code 39 Check Digit Verification 5-50 Transmit Code 39 Check Digit 5-51 Enable/Disable Code 39 Full ASCII 5-52 Convert Code 39 to Code 32 5-53 Code 32 Prefix 5-54 Enable/Disable Code 93 5-55 Set Lengths for Code 93 5-56 Enable/Disable Interleaved 2 of 5 5-58 Set Lengths for Interleaved 2 of 5 5-59 I 2 of 5 Check Digit Verification 5-61 Transmit I 2 of 5 Check Digit 5-62 Convert I 2 of 5 to EAN-13 5-63 Enable/Disable Discrete 2 of 5 5-64 Set Lengths for Discrete 2 of 5 5-65 Enable/Disable Codabar 5-67 Set Lengths for Codabar 5-68 CLSI Editing 5-70 NOTIS Editing 5-71 Enable/Disable MSI Plessey 5-72 Set Lengths for MSI Plessey 5-73 MSI Plessey Check Digits 5-75 Transmit MSI Plessey Check Digit 5-76 MSI Plessey Check Digit Algorithm 5-77 Transmit Code ID Character 5-78
Symbol Code ID Characters 5-78 Pause Duration 5-80 RS-232C Parameters 5-81
Baud Rate 5-81 Baud Rate (Continued) 5-82 Parity 5-83 Parity (Continued) 5-84 Check Receive Errors 5-85 Hardware Handshaking 5-86 Hardware Handshaking (Continued) 5-87 Hardware Handshaking (Continued) 5-88 Software Handshaking 5-88 Software Handshaking (Continued) 5-89 Software Handshaking (Continued) 5-90 Host Serial Response Time-out 5-90 RTS Line State 5-91 Stop Bit Select 5-92 ASCII Format 5-92

Intercharacter Delay 5-93 MCL-Net Parameters 5-93
MCL-Net Baud Rate 5-93 MCL-Net Baud Rate (Continued) 5-95 MCL-Net Hex Addressing Mode 5-96 Scanner Address 5-97 MCL-Net Transmit Retries 5-97 MCL-Net Frame Timeout 5-97 Scanner Decode Beep Type 5-98 Long Range Scanning Bar Codes 5-99
Aim Mode 5-99 Aim Duration 5-100 Numeric Bar Codes 5-101 Cancel 5-103
UCC/EAN-128 A-1 AIM Code Identifiers A-3
Appendix C. Radio Channels
Cordless Phaser RF Channels Per Country C-1
Introduction D-1 Messages D-1 Communication Errors D-2
Scanning Transmission Range D-2
Feedback
Contents



Introduction
The P470/P370 RF Scanners Product Reference Guide provides general instructions for setup, operation, troubleshooting, maintenance, and programming the P370 (industrial) and P470 (retail) cordless RF scanners.
The following conventions are used in this document:

If you have a problem with your equipment, contact the Symbol Support Center for your region. See page xi for contact information. Before calling, have the model number, serial number, and several of your bar code symbols at hand.
Call the Support Center from a phone near the scanning equipment so that the service person can try to talk you through your problem. If the equipment is found to be working properly and the problem is symbol readability, the Support Center will request samples of your bar codes for analysis at our plant.
If your problem cannot be solved over the phone, you may need to return your equipment for servicing. If that is necessary, you will be given specific directions.
during shipment if the approved shipping container is not used. Shipping the units improperly can possibly void the warranty. If the original shipping container was not kept, contact Symbol to have another sent to you.

For service information, warranty information or technical assistance contact or call the Symbol Support Center in:
Canada Symbol Technologies Canada, Inc. 2540 Matheson Boulevard East Mississauga, Ontario, Canada L4W 4Z2 905-629-7226
Symbol Technologies, Inc. One Symbol Plaza Holtsville, New York 11742-1300 1-800-653-5350
United Kingdom Symbol Technologies Symbol Place Winnersh Triangle, Berkshire RG41 5TP United Kingdom 0800 328 2424 (Inside UK) +44 118 945 7529 (Outside UK)
Asia/Pacific Symbol Technologies Asia, Inc. 230 Victoria Street #04-05 Bugis Junction Office Tower Singapore 188024 337-6588 (Inside Singapore) +65-337-6588 (Outside Singapore)
Australia Symbol Technologies Pty. Ltd. 432 St. Kilda Road Melbourne, Victoria 3004 1-800-672-906 (Inside Australia) +61-3-9866-6044 (Outside Australia)
Austria/Österreich Symbol Technologies Austria GmbH Prinz-Eugen Strasse 70 Suite 3 2.Haus, 5.Stock 1040 Vienna, Austria 1-505-5794 (Inside Austria) +43-1-505-5794 (Outside Austria)
Denmark/Danmark Symbol Technologies AS Gydevang 2, DK-3450 Allerod, Denmark 7020-1718 (Inside Denmark) +45-7020-1718 (Outside Denmark)
Europe/Mid-East Distributor Operations Contact your local distributor or call +44 118 945 7360
About This Guide · United States 1

Finland/Suomi Oy Symbol Technologies Kaupintie 8 A 6 FIN-00440 Helsinki, Finland 9 5407 580 (Inside Finland) +358 9 5407 580 (Outside Finland)
France Symbol Technologies France Centre d'Affaire d'Antony 3 Rue de la Renaissance 92184 Antony Cedex, France 01-40-96-52-21 (Inside France) +33-1-40-96-52-50 (Outside France)
Germany/Deutchland Symbol Technologies GmbH Waldstrasse 68 D-63128 Dietzenbach, Germany 6074-49020 (Inside Germany) +49-6074-49020 (Outside Germany)
Italy/Italia Symbol Technologies Italia S.R.L. Via Cristoforo Columbo, 49 20090 Trezzano S/N Navigilo Milano, Italy 2-484441 (Inside Italy) +39-02-484441 (Outside Italy)
Latin America Sales Support 7900 Glades Road Suite 340 Boca Raton, Florida 33434 USA 1-800-347-0178 (Inside United States) +1-561-483-1275 (Outside United States)
Mexico/México Symbol Technologies Mexico Ltd. Torre Picasso Boulevard Manuel Avila Camacho No 88 Lomas de Chapultepec CP 11000 Mexico City, DF, Mexico 5-520-1835 (Inside Mexico) +52-5-520-1835 (Outside Mexico)
Norway/Norge Symbol Technologies Trollasveien 36 Postboks 72 1414 Trollasen, Norway 66810600 (Inside Norway) +47-66810600 (Outside Norway)
Symbol Technologies Kerkplein 2, 7051 CX Postbus 24 7050 AA Varsseveld, Netherlands 315-271700 (Inside Netherlands) +31-315-271700 (Outside Netherlands)
Netherlands/Nederland

South Africa Symbol Technologies Africa Inc. Block B2 Rutherford Estate 1 Scott Street Waverly 2090 Johannesburg Republic of South Africa 11-4405668 (Inside South Africa) +27-11-4405668 (Outside South Africa)
Spain/España Symbol Technologies S.A. Edificioi la Piovera Azul C. Peonias, No. 2 - Sexta Planta 28042 Madrid, Spain +913244000 (Inside Spain) +34-9-1-320-39-09 (Outside Spain)
Sweden/Sverige Symbol Technologies AB Albygatan 109D Solna Sweden 84452900 (Inside Sweden) +46 84452900 (Outside Sweden)
1Customer support is available 24 hours a day, 7 days a week.
If you purchased your Symbol product from a Symbol Business Partner, contact that Business Partner for service.
For the latest version of this guide go to:http://www.symbol.com/manuals
Symbol Technologies, Inc. (“Symbol”) manufactures its hardware products in accordance with industry-standard practices. Symbol warrants that for a period of twelve (12) months from date of shipment, products will be free from defects in materials and workmanship. This warranty is provided to the original owner only and is not transferable to any third party. It shall not apply to any product (i) which has been repaired or altered unless done or approved by Symbol, (ii) which has not been maintained in accordance with any operating or handling instructions supplied by Symbol, (iii) which has been subjected to unusual physical or electrical stress, misuse, abuse, power shortage, negligence or accident or (iv) which has been used other than in accordance with the product operating and handling instructions. Preventive maintenance is the responsibility of customer and is not covered under this warranty. Wear items and accessories having a Symbol serial number, will carry a 90-day limited warranty. Non- serialized items will carry a 30-day limited warranty.
About This Guide

During the warranty period, Symbol will repair or replace defective products returned to Symbol’s manufacturing plant in the US. For warranty service in North America, call the Symbol Support Center at 1-800-653-5350. International customers should contact the local Symbol office or support center. If warranty service is required, Symbol will issue a Return Material Authorization Number. Products must be shipped in the original or comparable packaging, shipping and insurance charges prepaid. Symbol will ship the repaired or replacement product freight and insurance prepaid in North America. Shipments from the US or other locations will be made F.O.B. Symbol’s manufacturing plant. Symbol will use new or refurbished parts at its discretion and will own all parts removed from repaired products. Customer will pay for the replacement product in case it does not return the replaced product to Symbol within 3 days of receipt of the replacement product. The process for return and customer’s charges will be in accordance with Symbol’s Exchange Policy in effect at the time of the exchange. Customer accepts full responsibility for its software and data including the appropriate backup thereof. Repair or replacement of a product during warranty will not extend the original warranty term. Symbol’s Customer Service organization offers an array of service plans, such as on-site, depot, or phone support, that can be implemented to meet customer’s special operational requirements and are available at a substantial discount during warranty period.
Except for the warranties stated above, Symbol disclaims all warranties, express or implied, on products furnished hereunder, including without limitation implied warranties of merchantability and fitness for a particular purpose. The stated express warranties are in lieu of all obligations or liabilities on part of Symbol for damages, including without limitation, special, indirect, or consequential damages arising out of or in connection with the use or performance of the product. Seller’s liability for damages to buyer or others resulting from the use of any product, shall in no way exceed the purchase price of said product, except in instances of injury to persons or property. Some states (or jurisdictions) do not allow the exclusion or limitation of incidental or consequential damages, so the preceding exclusion or limitation may not apply to you.

Introduction
The P470/P370 cordless RF scanners bring new flexibility and economy to data capture and data management in both industrial and retail operations. The scanner communicates with your host computer through radio transmission instead of through a cable. With the RF scanner, you are free to scan and transmit without a physical cable, from as far away as 100 feet (30.5 meters) even without a direct line of sight. This lets you take the scanner to where the work is, whether on the loading dock, the plant floor, the warehouse, or the POS checkout area. There are several versions available:
Unless otherwise noted, the term Phaser refers to all versions of the scanner.

In the handle of the scanner, there is a rechargeable lithium-ion battery. This provides all power to the scanner during cordless operation. It provides 10 hours of use in a typical application. When fully depleted, the battery can be recharged to full charge in about 3-1/2 hours.
The PL 370/470 Cradle acts as a:
The cradle can sit on a desktop or be wall-mounted, whichever is more convenient. The cradle receives data from the scanner via the antenna on the side of the cradle. The cradle then transmits that data to the host device via an attached cable. It also acts as a holder for the scanner.
The cradle also provides power for charging the scanner’s battery (in the scanner). The cradle has a charge status indicator light that shows the status of the battery charging (Refer to Table 4-1 on page 4-3).
Charge Status Indicator Light
There are two versions of the cradle:
Unless otherwise noted, the term Cradle refers to both versions of the cradle.

The P470/P370 RF Scanner
Below is an index of Quick Startup Instructions to help get you up and going quickly. These instructions are also on the back cover of this guide for easy reference. The index is listed in a step by step order beginning with step 1, Setting up the System.
Mandatory steps are designated by an asterisk (*). If an item has multiple pages referenced, the most important reference is in bold.
- RS-232 connection 2-2
- Synapse connection (keyboard wedge, USB, etc.) 2-3
- RF channel 3-8, 5-13, C-1
- Coexisting in Spectrum24 environments 2-7
- RS-232 baud rate 5-81
PRG Page


Below are commonly used programming bar codes. You can cut this page out of the guide, or make a copy of the bar codes using a high quality copying machine.
Reset Default Application (Clears previously programmed ADF rules and/or

Set Up
Introduction
This chapter covers the procedures for setting up the RF scanner and its accessories.
Remove the scanner from its packing and inspect it for damage. If the scanner was damaged in transit, call one of the telephone numbers listed in the section Symbol Support Center on page xi. KEEP THE PACKING. It is the approved shipping container and should be used if you ever need to return your equipment for servicing.
The basic steps to set up the cradle are listed below and described in more detail in the following sections.
With some host types, the scanner is unable to answer host terminal polls if the appropriate host type is not selected. This may result in an error message generated by the host. To correct this situation, select the proper parameter set and initialize the host terminal. See Chapter 5, Parameter Menus for more information.

There are two basic host communications options available:
Figure 2-1. Ports on the Cradle
Power port

Before power is provided to the cradle (step 6), the following steps must be completed. The Synapse cable must be connected to the cradle (step 2) AND the flying power lead plugged in (step 4). If the cables are not connected in this sequence, the Synapse Interface Adapter will not operate properly.
Synapse Interface Adapter (Module)

See the appropriate Synapse cable instructions. An adapter cable is required.
Before wall-mounting the cradle, the scanner support tab must be changed from the desk- mount position to the wall-mount position.
Desk Mount Wall Mount
Cable Grooves

Set Up

The scanner and cradle must be paired for communication to occur.
To pair the scanner with the cradle:
To pair a long range scanner (P370 ALR) to a regular P370 cradle, attach the “spare pairing bar code” label to the cradle. This 15 mil bar code, packaged with the cradle, can be scanned by the P370 ALR at a distance of approximately two feet from the cradle.
during over-the-air pairing. To reduce the pairing time, place the scanner in the cradle.
Successful pairing is indicated by a warble beep and the base’s LED will flash. If pairing is unsuccessful, the scanner emits a Lo/Hi beep and displays the following message:
Pairing Unsuccessful Push ENTER & Try Again
The pairing of a scanner to a cradle is one-to-one. Only one scanner can be paired to a cradle at any point in time. If you pair a second scanner to an in use cradle, the cradle’s connection to the first scanner will be broken and the connection re-established with the second scanner.
To pair a scanner to a different cradle, scan its pairing bar code located on the top of the cradle.

Mounting
The RF scanner and cradle are equipped with a 2.4 GHz point-to-point radio that has an RF transmission range of 100 feet (30.5 meters) even without a direct line of sight.
In addition to being a 2-way RF transmitter, the cradle is a battery charger and should be mounted in an accessible location like on a table or desktop. For optimum RF performance, especially in difficult environments, mount the cradle on a wall as high as possible.
If you operate your scanner or cradle in close proximity to a Spectrum24 device, maintain a buffer of 3 feet or greater between the transmitters. A Spectrum24 device includes but is not limited to a terminal with a Spectrum24 radio, PC with a Spectrum24 card, or a Spectrum24 Access Point. If a scanner or cradle is less than 3 ft. from a 2.4 GHz Spectrum24 transmitter (antenna), especially an Access Point, your communication performance may degrade.
In the unlikely event that Spectrum24 radio traffic causes interference between the scanner and the cradle, you can change the scanner’s RF channel to one that minimizes or eliminates the interference.
Phaser cordless scanners have three channels that are not within the Spectrum24 band, 81, 82, and 83*. As a rule of thumb, the Cordless systems operated closest to Spectrum24 devices should use these channels. For instructions on how to change the scanner’s RF channel, see System Setup Options on page 3-8.
In applications with low scanning/data transmission duty cycles, you may assign the same channel to more than one cordless scanner.
After channels 81, 82 and 83, the next best channels to use are 60 through 80; the higher the channel the better. See Appendix C, Radio Channels for a list of available radio channels per country.
* Not available in some countries.
Set Up

Up to three P470/370 scanners within listening range (100 feet) of each other can be operated on the same channel with little or no interference, assuming average scanning rates.
For higher than average scanning rates, P470/370 scanners within listening range (100 feet) of each other should be operated on different channels, set apart by at least one channel (for example, 2, 4, 6, etc.). Cordless Phaser scanners support up to 82 communication channels. Not all channels are available in all countries. Refer to Appendix C, Radio Channels for more information.
If the scanner’s transmission is not received by the cradle or the base’s acknowledgment response is not received by the scanner (see Communication Errors on page 3-5), the scanner retransmits the lost or corrupted data. The scanner attempts 4 RF Retries (default) but can be programmed to attempt up to 8.
Depending on your particular RF environment, additional retries may cause your scanner transaction time to increase in the presence of heavy Spectrum24 traffic.
Before its first use, the scanner’s battery must be charged. It can be charged:

The cradle recharges batteries in the scanner only when the scanner is in the cradle. A scanner with a depleted battery starts charging immediately upon insertion into the cradle, whereas a scanner with a partially charged battery begins charging after approximately 15 minutes. Note that the scanner can be removed from the cradle at any time.
The battery can be charged using the Universal Battery Charger UBC 2000. The UBC adapter for the P470/P370 scanner battery is required. Refer to the UBC 2000 guide for information on recharging the battery using the UBC 2000.
When the battery’s charge is almost depleted, the scanner emits 4 high tone beeps, when the trigger is pulled, indicating that it must be recharged.
Set Up



Introduction
This chapter covers how to use the cordless Phaser scanner.
The cordless scanner is shipped from the factory with a default scan and transmit application.
This application allows users to scan and view data, enter quantities, and manually enter alphanumeric data.
When the unit is powered up, it displays the system start-up banner. Alternatively, the scanner can be reset manually by pressing the key, then the key. When the scanner is powered up or reset, the system banner appears as follows:
Symbol Technologies · Phaser RF

After a few seconds, the System Banner is replaced by the system initialization screen.
Symbol Technologies Initializing...
After initialization, the scanner enters the Scan & Transmit application. The default communication protocol is RS232/Synapse.
If a Synapse cable is attached, the scanner automatically overrides the default settings.
The scan and transmit application allows you to:
If the scanner powers down, pull the trigger or press the key to wake it up.
The scan and transmit screen appears as follows:
In this mode, scanned bar codes are automatically transmitted to the cradle and then the host in real time.
The default application also allows you to manually enter data if no bar code is present.
By default, this feature is enabled. To disable alphanumeric data entry via the keypad, go to the symbologies tab inside 123Scan and remove the “X” from the check box next to “Keypad”. (This does not disable the quantity entry feature discussed in Eliminating Repetitive Scanning on page 3-4.)

With keypad entry enabled (default setting out of the box), press the key after keying in data. During data entry, the key corrects keying errors digit by digit, and the then combination clears the screen so you can start over. If your entry exceeds 34 characters, the characters will scroll off the visible portion of the screen, but are retained for storage.
To enter alpha characters via the keypad (with keypad enabled, page 3-26), press the key once to put the scanner in Alpha Mode.
Numeric buttons 1 through 9 are associated with the alpha characters. For example, the letters A, B and C are located on numeric button 7. Press the button with the letter you desire - once for the letter A, twice for the letter B, or three times for the letter C. You can continue entering alpha characters or switch to numerics. Press to send the data.
To return to numeric entry mode after entering alpha characters, press the key again. For example, to manually enter 17ABF5, do the following steps:
1 Press numeric button 1.
7 Press numeric button 7.
A Press button once, then numeric button 7 once. Wait for one second (you will hear a low pitched beep).
B Press numeric button 7 twice.
F Press numeric button 8 three times.
5 Press button once, then numeric button 5 once, then .
For more information, refer to Keypad Operation on page 3-26.
Operation · Data Action

To eliminate repetitive scanning of identical items, you can enter a quantity prior to scanning a bar code. This quantity entry feature can also be used when manually entering bar code data.
To enter a quantity, press the * key. The following screen with a default value of “1” will appear:
To enter the value you desire, key in the quantity followed by the key. Next, the bar code data entry screen reappears. Scan the item’s bar code. The scanner sends the bar code data to the host the keyed-in amount of times. For instance, if you type in a quantity of 6 then scan a bar code, the scanner sends that bar code data to the host six times as if the bar code had been scanned six times.
If you have accidentally entered this screen, it will automatically be exited after 5 seconds or by pressing the key without entering a quantity.

A communication error occurs when the scanner, cradle or host fails to properly communicate. When a communication error occurs using the default application, the scanner emits 4 beeps (LO HI LO HI) and displays a "Failed Communication" error message, like the one shown below. The three-digit error code on the scanner screen indicates what type of communication problem occurred. Error code 015 generally indicates the scanner is out of RF range, not properly paired to the base, or the base may have lost power. For a detailed list of all the error codes see Appendix D, Messages and Error Codes and Beeper Indications / Default Application Error Codes on page 4-7.
Failed Communication Error 015 Push ENTER
To return to the application, press .
Three types of communication errors can occur:
2. If the cradle received the RF transmitted data, but the scanner did NOT receive a cradle's acknowledgment, move the scanner closer to the cradle to reestablish communication, then re-scan the bar code. If the communication has been reestablished, the scanner will sound a good decode beep and no error beeps. In this scenario data may have been transmitted to the host. If the cradle had previously sent data to the host, it will NOT pass this re-scanned data to the host. Resume normal scanning.
For additional information see Optimizing RF Performance on page 2-7.
Operation


The system menu allows the user to set up the operation of the scanner, such as loading a new application, set the scanner’s RF channel, setting the scanner ID, etc.
Enter the System Menu by scanning the bar code below or by entering a keypad sequence.
Commonly used System Menu programming bar codes have been consolidated on page 1-4.
Enter System Menu Bar Code
To access the System Menu using the keypad sequence, press the , then the key, followed by the key, then the key.
When you enter the system menu, the following screen appears:
Phaser Setup 0. System Setup
Below is the list of available options. Press the Up and Down arrow keys to scroll through them. Press to select a menu option. You can also select a menu option directly by typing the associated menu option number and then pressing .
The system menu options are described below.
Operation

System Setup allows you to configure the scanner’s basic settings such as setting an RF channel.
Sets the communication protocol used by the default application. The options are MCL-Net or RS232/Synapse. If RS232/Synapse is selected, the scanner automatically identifies whether an RS- 232 or Synapse interface is required. To cancel the change, press the then keys, and to accept the change, press the key.
The cordless Phaser scanner operates on a single, programmable channel (frequency) between 2.402 GHz (channel 02) and 2.483 GHz (channel 83).
A maximum of 81 channels are available. Not all channels are available in all countries. If a channel is not legal to use in your country, an error beep will be heard instead of a successful warble. For a list of Channel Availability by Country, see Appendix C, Radio Channels.
To cancel the change, press the then keys, and to accept the change, press the key.
Option Description

App. Control allows you to control your application, specifically, load new applications on your scanner, reset your default applications, etc.
You can load a new application or system code by either scanning the appropriate bar code or entering the appropriate keypad value as indicated on the display.
OR To enter this mode from an application without entering the system menu or entering key strokes, scan the bar code below.
Load New MCL-Designer Application
Scanner ready, on PC start download
When this screen displays, the scanner is ready to accept the download. On the PC Utility, initiate the download. After downloading is complete, the system menu is exited and the application initiated. To exit this mode and prevent the download of a new application, press the then keys.
Operation · Option Description

Press the key to confirm the choice (Yes) or the key to cancel the choice (No). If you entered “Set Default App” from the System Menu, upon resetting the default application, you will return to the System Menu.
OR To enter this mode from an application without entering the system menu or entering key strokes, scan the bar code below.
Reset Default Application (Clears previously programmed ADF rules and/or
If you entered the “Set Default App” mode using the bar code above, the default application will automatically be reset, the System Menu exited, and the application re-initiated.
Option Description · MCL-Designer applications)

Enables the automatic application download feature in the default application. This allows the user to remove the scanner from the box, pair it with the cradle, place the scanner in the cradle and automatically download a new application to the scanner.
In order for this feature to operate properly, the cradle must be connected to a host running MCL-Link, and the user’s host must be configured properly with specific files in specific locations (See Appendix A). If the user does not set up the host in the required manner, the scanner reverts to normal charging mode. This feature is enabled by default, but may be disabled by use of this System Menu item.
Selecting Enable will enable this feature; Disable will disable this feature. To exit without changing this setting, press then .
Operation · Option Description · -Enable -Disable

Press the key to confirm the choice (Yes) or the key to cancel the choice (No).
OR To enter this mode from an application without entering the system menu or entering key strokes, scan the bar code below.
Place unit in cradle on PC start download
Place the scanner in the cradle before initiating the download from the PC Utility. After the download is complete, the system menu is exited and the application initiates. To exit this mode and prevent the download of new firmware, press and hold the key for 30 seconds. In addition, power to the cradle must be cycled (powered off then on) before it will communicate with the scanner again.
Option Description · System Code

Press the key to confirm the choice (Yes) or the key to cancel the choice (No).
OR To enter this mode from an application without entering the system menu or entering key strokes, scan the bar code below.
Base Station ready, on PC start download
To start the download to the cradle, press the start button on the PC Utility. Note: You will automatically exit this message after 15 seconds and return to the application, even if the PC download is NOT initiated.
To exit this mode and prevent the download of new firmware or if the PC download is not initiated, the power to the cradle must be cycled (powered off then on) before it will communicate with the scanner again. No action is required on the scanner side.
Operation · Option Description · Base Station Code

Parameter Control allows you to control the scanner parameters such as Scan Parameters and Set Default Params.
Scan Parameters to quit
After scanning the desired bar codes, press then to exit this mode.
System Status allows you to perform system checks such as Battery Check.
Option Description · Option Description · Recharge Battery

To enter this mode using the keypad, select this option on the System Menu. The following screen displays.
If you entered “Scanner Version” from the System Menu, after 15 seconds or by pressing , you will return to the System Menu.
OR To enter this mode from an application outside of the System Menu, scan the bar code below.
If you entered “Scanner Version” using the bar code above, after 15 seconds or by pressing , you will automatically exit the System Menu and re-enter the application.
Operation · Scanner Firmware Version

To enter this mode using the keypad, select this option on the System Menu. The following screen displays.
If you entered “Cradle Version” from the System Menu, after 15 seconds or by pressing , you will return to the System Menu.
OR To enter this mode from an application outside of the System Menu, scan the bar code below.
If you entered “Cradle Version” using the bar code above, after 15 seconds or by pressing , you will automatically exit the System Menu and re-enter the application.
Return to App. Return to App exits the system menu and returns to the application. To do this, press then .
Cradle Firmware Version

123Scan is an intuitive Windows based utility that allows you to customize your scanner setup and generate Advanced Data Formatting (ADF) rules. An Advanced Data Formatting rule gives you the ability to modify the bar code data before sending it to the host such as appending a carriage return, or some other prefix/suffix value, to the bar code data. This enhances capability between bar code data and your host software, allowing you to program the scanner rather than modifying your host application. The cordless scanner can be programmed via a cordless (RF) download or by scanning 123Scan generated programming bar codes. Scanner programming is saved in a setup file which can be distributed electronically (Web site, floppy disk, E-mail, or fax).
A copy of 123Scan is on the CD included with your scanner. It is also available on the Symbol Web site http://www.symbol.com. Use the web site’s search tool to find “123Scan” and select the P470/370 product line.
with the default application only and will not work with applications created with MCL-Designer.
To download a 123Scan generated ADF rule, scan the bar code below, then initiate the download on the PC utility.
To remove previously programmed ADF rules from the scanner, scan the bar code below.
Reset Default Application (Clears previously programmed ADF rules)
Operation · Load 123Scan File


123Scan generated programming bar codes for two commonly used suffixes (Enter and Tab) have been included in this Product Reference Guide.
To append an Enter key* to the transmitted bar code data, scan all nine (9) ADF rule bar codes and then the Reset Scanner bar code, in that order.


Operation

To append a Tab* to the transmitted bar code data, scan all nine (9) ADF rule bar codes and then the Reset Scanner bar code, in that order.



Operation

The scanner ships with the default application and default parameters and is ready-to-use right out of the box. If this is not what you need for your application, refer to the MCL Designer Manual for programming instructions and Chapter 5, Parameter Menus for scanning and communications parameters. If you need assistance, contact your local supplier or Symbol Support Center.
Scan the Entire Symbol


Do not hold the scanner directly over the bar code. Laser light reflecting directly back into the scanner from the bar code is known as specular reflection. This strong light can “blind” the scanner and make decoding difficult. The area where specular reflection occurs is known as a “dead zone.”
You can tilt the scanner up to 65° forward or back and still achieve a successful decode. Simple practice quickly shows what tolerances to work within.
Scan Beam Scan Beam
Bar Code Bar Code Bar Code
Operation

15.6 in. 39.6 cm
10 in. 25.4 cm
5 in. 12.7 cm
0 in. 0 cm
5 in. 12.7 cm
10 in. 25.4 cm
7.5 mil
15.6 in. 39.6 cm
0 in. 0 cm 5 in. 12.7 cm 10 in. 25.4 cm 15 in. 38.1 cm 20 in. 50.8 cm 25 in. 63.5 cm 30 in. 76.2 cm 35 in. 88.9 cm 40 in. 101.6 cm 45 in. 114.3 cm
Distance From Front Of Scanner

20.0 in. 50.4 cm
15.0 in. 38.1 cm
10 in. 25.4 cm
5 in. 12.7 cm
0 in. 0 cm
5 in. 12.7 cm
10 in. 25.4 cm
15.0 in. 38.1 cm
20.0 in. 50.8 cm
0 in. 0 cm 35 in. 88.9 cm 70 in. 177.8 cm 105 in. 266.7 cm 140 in. 355.6 cm 175 in. 444.5 cm 210 in. 533.4 cm 245 in. 622.3 cm 280 in. 711.2 cm 315 in. 800.1 cm
350 in. 889.0 cm 385 in. 977.9 cm
Distance From Front Of Scanner

Instead of scanning a bar code, you can enter the bar code data using the keypad on the top of the scanner. By default, this feature is enabled. To disable alphanumeric data entry via the keypad, go to the symbologies tab inside 123Scan and remove the “X” from the check box next to “Keypad”. (This does not disable the quantity entry feature discussed in Eliminating Repetitive Scanning on page 3-4.)
For additional information on 123Scan, see 123Scan on page 3-17.
To enter numeric data, type the numeric value desired and press . A beep lets you know that the entry was accepted. See Figure 3-5 on page 3-27.
To enter alpha characters, press the key once to put the scanner in Alpha Mode.
Numeric buttons 1 through 9 are associated with the alpha characters. For example, the letters A, B and C are located on numeric button 7. Press the button with the letter you desire - once for the letter A, twice for the letter B, or three times for the letter C. You can continue entering alpha characters or switch to numerics. Press to save or send the data.
To return to numeric entry mode after entering alpha characters, press the key again. For example, to manually enter 17ABF5, do the following steps:
1 Press numeric button 1.
7 Press numeric button 7.
A Press button once, then numeric button 7 once. Wait for one second (you will hear a low pitched beep).
B Press numeric button 7 twice.
F Press numeric button 8 three times.
5 Press button once, then numeric button 5 once, then .
Every time you press the button with the letter you desire, you hear a low-pitched beep to let you know that the entry was registered. Although the entry is registered, it has not been
Data Action

transferred to the host yet. A high-pitched beep lets you know that the entry has been transferred to the host.
To return to numeric mode, press the Mode key again. Pressing the Enter key saves the data.
To put a decimal point (.) into numeric data, type in the numbers before the decimal point, then press the mode key, press the decimal, and press the mode key again. Now resume typing in the values to the right of the decimal.
To enter a dash (-), press the mode key once, then the zero (0) key twice.
To enter a blank space ( ), press the mode key once, then the zero (0) key three times.
The Function key in combination with a numeric key can be programmed to launch an operation. For more information on how to program these keys for additional tasks and operations, refer to the MCL Designer User’s Guide p/n 70-37689-XX.
Operation

Refer to Appendix D, Messages and Error Codes for additional troubleshooting information.
General problem solving • Check that the power supply is attached to the cradle.
The scanner emits error beeps after decoding a bar code.
Problem Solution

The scanner does not scan the programming bar codes in this PRG.
The PC cannot download an application to the scanner.
Received an 015 communication error while using a Synapse cable.
The P370 ALR scanner will not pair with a PL370 cradle.
Operation · Problem Solution

The Scanner will not load my ADF rule.
contact your distributor or call the Symbol Support Center. See Symbol Support Center on page page xi for the telephone number.
Problem Solution

Introduction
This chapter explains how to maintain your scanner and the specifications for it.
Once a battery is fully charged, it will generally last up to 10 hours without being returned to the cradle. By returning it to the cradle during the day, you extend this time.



The LED indicator on the cradle uses flashing patterns to display the charger status, as shown in the table below.
Off The scanner is not in the cradle or has not been properly inserted into the cradle.
Blinking Slowly The scanner is properly seated in the cradle and charging will begin shortly.
Blinking Rapidly The battery is actively charging.
On Battery charging is complete.
Maintenance And Specifications · LED Status

Decode Capability The RF scanner can be programmed to decode the following code types: UPC/EAN, Bookland EAN, Code 11, Code 39, Code 39 Full ASCII, Trioptic Code 39, Code 93, Codabar, Interleaved 2 of 5, Code 128, EAN 128, Discrete 2 of 5, MSI Plessey, and Coupon Code. The RF scanner can auto-discriminate between all of the above code types except for Code 39 and Code 39 Full ASCII.
Scanner Beeper Operation User-selectable: Enabled, Disabled.
Scan Repetition Rate 35 (± 5) scans/sec (bidirectional)
Roll (Skew) Tolerance ± 30° from normal
Pitch ± 65° from normal
Yaw ± 60° from normal
Decode Depth of Field See Decode Zone on page 3-24.
Print Contrast Minimum 20% absolute dark/light differential, measured at the wavelength of the laser diode.
Artificial Lighting 450 ft. candles 4844 lux
Sunlight 10,000 ft. candles 107,640 lux
P370 (Industrial) P470 (Retail)
-4° to 122°F -20° to 50°C 32° to 104°F 0° to 40°C
Storage Temperature -40° to 140°F -40° to 60°C
Sealing P370: All components sealed to IP 54 specification against wind blown dust and rain.
Humidity 5% to 95% (non-condensing)
P370 (Industrial) P470 (Retail)

Height 7.0 in. (17.8 cm)
Width 9.2 in. (13.5 cm)
Depth 3.5 in. (9.8 cm)
Laser Classifications CDRH Class II, IEC Class 1, IEC Class 2
Maintenance And Specifications · Item Description · Dimensions

The following table shows the pin-outs for COM1 on the cradle.
6 RXD IN
7 TXD OUT
8 DTR (Tied HI)
10 RTS - OUT

Table 4-4 list beep sequence and their meanings for standard beeps programmed into the scanner. Other applications written for the scanner can have their own beep sequences and therefore are not listed in this table. See your System Administrator for beep sequences and their meanings.
For additional information on Error Codes, see Communication Errors on page 3-5.
Beeper Sequence Indication Default Application
Short high tone A bar code symbol was decoded (if decode beeper is enabled).
4 Beeps - long low A host transmission error occurred. Data was not successfully sent to the host device. This occurs if a unit is not properly configured. Check option settings.
Error code 003 Error code 009 Error code 018 Error code 247 Error code 249 Error code 253
5 Beeps - low tone Convert or format error. Error code 002 Error code 008
Hi/Hi/Hi/Lo tone RS-232 receive error. Error code 005
4 Beeps - short Hi Battery requires recharging. Low Battery
4 Beeps - Lo/Hi/Lo/Hi An RF transmission error has occurred. Move closer to the cradle and re-scan the bar code.
Error code 015 Error code 016 Error code 017 Error code 024
Short high tone Correct entry scanned or correct menu sequence performed.

Beeper Sequence Indication Default Application
Long Lo/Long Hi tone Input error, incorrect bar code or
“Cancel” scanned, wrong entry, incorrect bar code programming sequence; remain in program mode.
Hi/Lo tone Keyboard parameter selected. Enter value using bar code keypad.
Hi/Lo/Hi/Lo tone Successful program exit with change in the parameter setting.
4 Beeps - Lo/Hi/Lo/Hi followed by 2 Beeps - Lo/Hi
Correct entry scanned or correct menu sequence performed in the scanner but communication error with cradle has occurred.
Error Codes

Introduction
This chapter has the optional parameter bar codes necessary to program the RF scanner.
The RF scanner is shipped with the settings shown in Table 5-1. These default values are stored in non-volatile memory and are preserved even when the scanner is powered down. You can change these default values by scanning the appropriate bar codes included in this manual. These new values replace the standard default values in memory. The default parameter values can be recalled by scanning the bar code in the section Set Default Parameter on page 5-7.
The scanner automatically detects which cable it is attached to, either an RS-232 or a Synapse cable. If it is attached to an RS-232 cable and has either an ICL, Nixdorf, or Fujitsu host interface, then scan the appropriate bar code from page 5-10 after power up. Any other RS-232 host interface works with the default setting.
If it is attached to a Synapse cable, plug everything together as described on page 2-3 and then follow the directions that come with the Synapse cable for setting up the host interface.

The following table lists the defaults for all parameters. If you wish to change any option, scan the appropriate bar code(s). An asterisk (*) next to a bar code indicates the default.
Parameter Default Page Number
Set Default Parameter All Defaults 5-7
Scan & Transmit Application RS232/Synapse 5-8
RS-232 Host Type Standard 5-9
Host Response Timeout 5 seconds 5-12
RF Channel No Default Setting 5-13
RF Retries 4 5-13
Sleep Time 10 seconds 5-15
Decimal Separator Decimal Point (.) 5-16
Key Click Enabled 5-17
Beeper Tone High Frequency 5-18
Beeper Volume High 5-19
Power Detect Beep Enabled 5-20
Beep After Good Decode Enabled 5-21
Laser On Time 3.0 seconds 5-22
Transmit “No Read” Message Disabled 5-23
Linear Code Type Security Levels 1 5-24
Bi-directional Redundancy Disabled 5-26
Autodiscriminate Response Time 1.0 second 5-27
Communication Protocol · Beeper Options · Decode Options

Parameter Default Page Number
Bookland EAN Disabled 5-30
Decode UPC/EAN Supplementals Ignore 5-31
Decode UPC/EAN Supplemental Redundancy
Transmit UPC-A Check Digit Enabled 5-33
Transmit UPC-E Check Digit Enabled 5-33
Transmit UPC-E1 Check Digit Enabled 5-33
UPC-A Preamble System Character 5-34
UPC-E Preamble System Character 5-35
UPC-E1 Preamble System Character 5-36
Convert UPC-E to A Disabled 5-37
Convert UPC-E1 to A Disabled 5-38
EAN-8 Zero Extend Disabled 5-39
Convert EAN-8 to EAN-13 Type Type is EAN-13 5-40
UPC/EAN Security Levels 0 5-41
UPC/EAN Coupon Code Disabled 5-43

Parameter Default Page Number
Code 128 Enabled 5-44
Code 39 Enabled 5-46
Trioptic Code 39 Disabled 5-47
Set Length(s) for Code 39 2 to 55 5-49
Code 39 Check Digit Verification Disabled 5-50
Transmit Code 39 Check Digit Disabled 5-51
Code 39 Full ASCII Conversion Disabled 5-52
Convert Code 39 to Code 32 Disabled 5-53
Code 32 Prefix Disabled 5-54
Code 93 Disabled 5-55
Set Length(s) for Code 93 4-55 5-56
Interleaved 2 of 5
Interleaved 2 of 5 Enabled 5-58
Set Length(s) for I 2 of 5 14 5-59
I 2 of 5 Check Digit Verification Disabled 5-61
Transmit I 2 of 5 Check Digit Disabled 5-62
Convert I 2 of 5 to EAN 13 Disabled 5-63

Parameter Default Page Number
Discrete 2 of 5
Discrete 2 of 5 Disabled 5-64
Set Length(s) for D 2 of 5 12 5-65
Set Lengths for Codabar 5-55 5-69
CLSI Editing Disabled 5-70
NOTIS Editing Disabled 5-71
MSI Plessey Disabled 5-72
Set Length(s) for MSI Plessey Any Length 5-74
MSI Plessey Check Digits One 5-75
Transmit MSI Plessey Check Digit Disabled 5-76
MSI Plessey Check Digit Algorithm Mod 10/Mod 10 5-77
Transmit Code ID Character None 5-79

Parameter Default Page Number
RS-232 Parameters Standard 5-81
Baud Rate 9600 5-82
Check Receive Errors Disabled 5-85
Hardware Handshaking None 5-87
Software Handshaking None 5-88
Host Serial Response Time-out 2 Sec. 5-90
RTS Line State (cable use only) Low 5-91
Stop Bit Select 1 5-92
ASCII Format 8-Bit 5-92
Intercharacter Delay 0 5-93
MCL-Net Baud Rate 38400 5-93
MCL-Net Hex Addressing Mode Disabled 5-96
Scanner Address 001 5-97
MCL-Net Transmit Retries 3 5-97
MCL-Net Frame Timeout 500 ms 5-97
Scanner Decode Beep Type 1 5-98
Long Range Scanning Bar Codes
Aim Mode Sequential trigger/Aim 5-99
Aim Duration 0.8 Sec 5-100
Parity None 5-83 · MCL-Net

Scanning this bar code returns all parameters to the values listed in Table 5-1 (factory settings), but does not erase any programmed ADF rules.
Parameter Menus

The bar codes below set the communication protocol used by the Scan & Transmit default application.
The communication options are RS232/Synapse or MCL-Net. If you select RS232/ Synapse, the scanner automatically identifies whether an RS232 or Synapse interface is required. MCL-Net allows the scanner to communicate with a host running MCL-Link or MCL-Link Lite.
This communication protocol is used for the real time scanning and transmission of data to a host when a cable is attached to the cradle.
MCL-NET
default applications and will not work with applications created with MCL-Designer.

RS-232C Host Types
Most RS-232C hosts work fine with the default settings, however, three RS-232C hosts are set up with their own parameter default settings. Selecting the ICL, Fujitsu or Nixdorf RS- 232C host interface sets the defaults listed below. These defaults take precedence over Standard RS-232 defaults. So, if you select the Fujitsu RS-232C first, and then select the Standard RS-232 defaults, the Fujitsu defaults still take precedence. To return to the factory set defaults, scan the SET ALL DEFAULTS bar code on page 5-7.
NIXDORF
Parameter Standard ICL FUJITSU
Transmit Code ID No Yes Yes Yes
Data Transmission Format Data as is Data/Suffix Data/Suffix Data/Suffix
Suffix CR/LF CR CR CR
Baud Rate 9600
Parity None Even None Odd
Hardware Handshaking None RTS/CTS Option 3
None RTS/CTS Option 3
Software Handshaking None
Serial Response Time-out 2 Sec. 9.9 Sec. 2 Sec. 9.9 Sec.
Stop Bit Select One
ASCII Format 8-Bit
Beep On <BEL> Disabled
RTS Line State Low High Low *Low = No data to send
*In the Nixdorf Mode B, if CTS is Low, transmission of scan data is disabled. When CTS is High, bar code data is transmitted to the host.
Parameter Menus · Mode A/ · Mode B

Scan the appropriate bar code below to select an RS-232C Host Interface.



NIXDORF RS-232C Mode A

NIXDORF RS-232C Mode B

OPOS

Selecting the ICL, Fujitsu, or Nixdorf RS-232C host interface enables the transmission of Code ID Characters as listed below. These Code ID Characters are not programmable and are separate from the Transmit Code ID feature. The Transmit Code ID feature should not be enabled for these hosts.
ICL FUJITSU NIXDORF
UPC-A “A” “A” “A”
UPC-E “E” “E” “C0”
EAN-8 “FF” “FF” “B”
EAN-13 “F” “F” “A”
Code 39 “C” None “M”
Codabar “N” None “N”
Code 128 “L” None “K”
I 2 of 5 “I” None “I”
Code 93 None None “L”
D 2 of 5 “H” None “H”
UCC/EAN 128 “L” None “P”
MSI/Plessey None None “O”
Bookland EAN “F” “F” “A”
Trioptic None None None
Parameter Menus

This parameter indicates how long the scanner will wait for a response from the cradle, after the cradle has sent its data to the attached host device. The timeout ranges from 5 seconds to 64 seconds, in 1 second increments. The default is 5 seconds.To change the timeout value, scan the bar code below, then scan two bar codes using the Numeric Bar Codes on page 5-101.
HOST RESPONSE TIMEOUT (RANGE OF 5 TO 64 SECONDS)

Selects the RF channel used for radio transmissions and reception. The channel ranges are nation dependent (see Appendix C, Radio Channels for a list of Channel Availability by Country). To enter a range, scan the bar code below followed by 2 digits from the numeric bar code section (starting on page 5-101) to set the desired channel. If the channel is not legal for your country, an error beep will be heard instead of a successful warble. It is recommended that each scanner/cradle pair be set to a different channel than neighboring scanner/cradle pairs.
On a transmission, the radio will try to send the data a certain number of times prior to giving up if the receiving cradle is not responding. The following parameter allows the user to select how many retries should be tried. For additional information, see Increase the number of RF Retries on page 2-8.
*4 RETRIES
Parameter Menus · RF Channel



Scan the bar code below to select how long the scanner will “stay awake” (not power down) in seconds after a trigger pull or a key press. First scan this bar code, then enter a range from 05 to 32, using the Numeric Bar Codes on page 5-101. It can stay awake from 5 seconds to 32 seconds.
programmed may affect the battery life time for that session before needing a charge.

Parameter Menus

Scan the appropriate bar code below to select what separator to display when you hit the decimal point key on the keypad. Choose DECIMAL POINT (.) or COMMA (,).



Scan the appropriate bar code below to select whether the keypad click is enabled or not. Choose ENABLE or DISABLE.


Parameter Menus

Scan the appropriate bar code below to select a decode beep frequency (tone). Choose LOW FREQUENCY, MEDIUM FREQUENCY, or HIGH FREQUENCY.




Scan the appropriate bar code below to select a beeper volume. Choose LOW VOLUME, MEDIUM VOLUME, or HIGH VOLUME.



Parameter Menus

Scan the appropriate barcode below to enable or disable the Power Detection Beep.
*POWER DETECT BEEP ENABLED

Scan the appropriate bar code below to select whether or not the scanner beeps after a good decode. If DO NOT BEEP is selected, the beeper still operates during parameter menu scanning and indicates error conditions.


Parameter Menus

This parameter sets the maximum time decode processing continues during a scan attempt. It is programmable in 0.1 second increments from 0.5 to 9.9 seconds.
Scan the bar code below to set a Laser On Time. Next scan two numeric bar codes beginning on page 5-101 that correspond to the desired time. Time less than 1.0 second must have a leading zero. For example, to set a Time On of 0.5 seconds, scan the bar code below, then scan the “0” and “5” bar codes. If you make an error, or wish to change your selection, scan CANCEL on page 5-103.
may affect the battery life time for that session before needing a charge.


Scan the appropriate bar code below to select whether or not a “No Read” message is transmitted. When enabled, if a symbol does not decode, “NR” is transmitted. When disabled, if a symbol does not read, nothing is sent to the host.


Parameter Menus

The scanner offers four levels of decode security for linear code types (e.g., Code 39, Interleaved 2 of 5). Higher security levels are selected for decreasing levels of bar code quality. As security levels increase, the scanner’s aggressiveness decreases.
Select the security level appropriate for your bar code quality.
The following code types must be successfully read twice before being decoded:
MSI Plessey 4 or less
D 2 of 5 8 or less
I 2 of 5 8 or less

Linear Security Level 2
All code types must be successfully read twice before being decoded.

Code Type Length · Codabar All

Linear Security Level 3
Code types other than the following must be successfully read twice before being decoded. The following codes must be read three times:
MSI Plessey 4 or less
D 2 of 5 8 or less
I 2 of 5 8 or less

Linear Security Level 4
All code types must be successfully read three times before being decoded.

Parameter Menus · Code Type Length

This parameter is only valid when a Linear Code Type Security Level (see page 5-24) is enabled. When this parameter is enabled, a bar code must be successfully scanned in both directions (forward and reverse) before being decoded.



This parameter extends the length of time during which the scanner tries to detect which host it is connected to on power up.
must be used.


Parameter Menus · *1 second · 5 seconds

Scan the appropriate bar code below to enable or disable UPC-E or UPC-A.







Scan the appropriate bar code below to enable or disable EAN-8 or EAN-13.




Parameter Menus

Scan the appropriate bar code below to enable or disable Bookland EAN.



Supplementals are characters (either 2 or 5) that are added on according to specific code format conventions (e.g., UPC A+2, UPC E+2, EAN 8+2). Three options are available.
read or ignore supplemental characters.



Parameter Menus

With Autodiscriminate UPC/EAN Supplementals selected, this option adjusts the number of times a symbol without supplementals is decoded before transmission. The range is from two to 20 times. Five or above is recommended when decoding a mix of UPC/EAN symbols with and without supplementals, and the autodiscriminate option is selected.
Scan the bar code below to select a decode redundancy value. Next scan two numeric bar codes beginning on page 5-101. Single digit numbers must have a leading zero. If you make an error, or wish to change your selection, scan CANCEL on page 5-103.


Scan the appropriate bar code below to transmit the symbol with or without the UPC-A, UPC-E, or UPC-E1 check digit.






Parameter Menus

Three options are given for lead-in characters for UPC-A symbols transmitted to the host device: transmit system character only, transmit system character and country code (“0” for USA), and no preamble transmitted. The lead-in characters are considered part of the symbol.

(<DATA>)


SYSTEM CHARACTER & COUNTRY CODE (< COUNTRY CODE> <SYSTEM CHARACTER> <DATA>)

Three options are given for lead-in characters for UPC-E symbols transmitted to the host device: Transmit system character only, transmit system character and country code (“0” for USA), and no preamble transmitted. The lead-in characters are considered part of the symbol.

(<DATA>)


SYSTEM CHARACTER & COUNTRY CODE (< COUNTRY CODE> <SYSTEM CHARACTER> <DATA>)
Parameter Menus

Three options are given for lead-in characters for UPC-E1 symbols transmitted to the host device: Transmit system character only, transmit system character and country code (“0” for USA), and no preamble transmitted. The lead-in characters are considered part of the symbol.

(<DATA>)


SYSTEM CHARACTER & COUNTRY CODE (< COUNTRY CODE> <SYSTEM CHARACTER> <DATA>)

This parameter converts UPC-E (zero suppressed) decoded data to UPC-A format before transmission. After conversion, data follows UPC-A format and is affected by UPC-A programming selections (e.g., Preamble, Check Digit).
Scanning DO NOT CONVERT UPC-E TO UPC-A allows you to transmit UPC-E (zero suppressed) decoded data.

(ENABLE)

Parameter Menus

This parameter converts UPC-E1 decoded data to UPC-A format before transmission. After conversion, data follows UPC-A format and is affected by UPC-A programming selections (e.g., Preamble, Check Digit).
Scanning DO NOT CONVERT UPC-E1 TO UPC-A allows you to transmit UPC-E1 decoded data.

(ENABLE)


If this parameter is enabled, five leading zeros are added to decoded EAN-8 symbols to make them compatible in format to EAN-13 symbols.
Disabling this parameter returns EAN-8 symbols to their normal format.


Parameter Menus

When EAN Zero Extend is enabled, this parameter gives you the option of labeling the extended symbol as either an EAN-13 bar code, or an EAN-8 bar code.
When EAN Zero Extend is disabled, this parameter has no effect on bar code data.



The scanner offers four levels of decode security for UPC/EAN bar codes. Increasing levels of security are provided for decreasing levels of bar code quality. There is an inverse relationship between security and scanner aggressiveness, so be sure to choose only that level of security necessary for any given application.
This is the default setting which allows the scanner to operate in its most aggressive state, while providing sufficient security in decoding “in-spec” UPC/EAN bar codes.

UPC/EAN Security Level 1
As bar code quality levels diminish, certain characters become prone to mis-decodes before others (i.e., 1, 2, 7, 8). If you are experiencing mis-decodes of poorly printed bar codes, and the mis-decodes are limited to these characters, select this security level.

Parameter Menus

UPC/EAN Security Level 2
If you are experiencing mis-decodes of poorly printed bar codes, and the mis-decodes are not limited to characters 1, 2, 7, and 8, select this security level.

UPC/EAN Security Level 3
If you have tried Security Level 2, and are still experiencing misdecodes, select this security level. Be advised that selecting this option is an extreme measure against mis-decoding severely out of spec bar codes. Selection of this level of security significantly impairs the decoding ability of the scanner. If this level of security is necessary, you should try to improve the quality of your bar codes.


When this parameter is enabled, the scanner decodes UPC-A, UPC-A with 2 supplemental characters, UPC-A with 5 supplemental characters, and UPC-A/EAN128 bar codes. AUTODISCRIMINATE UPC/EAN SUPPLEMENTALS on page 5-31 must be enabled.


Parameter Menus

Scan the appropriate bar code below to enable or disable Code 128.


the barcode to be scanned when using Code 128.

Scan the appropriate bar code below to enable or disable UCC/EAN-128. (See Appendix A, Bar Code Information for details on UCC/EAN-128.)


Lengths for Code 128
No length setting is required for Code 128. The default setting is Any Length.
Parameter Menus

Scan the appropriate bar code below to enable or disable Code 39.



Trioptic Code 39 symbols always contain six characters. Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneously. If you get an error beep when enabling Trioptic Code 39, disable Code 39 Full ASCII and try again. To enable or disable Trioptic Code 39, scan the appropriate bar code below.


Parameter Menus

Lengths for Code 39 may be set for any length, one or two discrete lengths, or lengths within a specific range. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. If Code 39 Full ASCII is enabled, Length Within a Range or Any Length are the preferred options.
One Discrete Length - This option allows you to decode only those codes containing a selected length. For example, if you select Code 39 One Discrete Length, then scan 1, 4, only Code 39 symbols containing 14 characters are decoded. Numeric bar codes begin on page 5-101. If you make an error, or wish to change your selection, scan CANCEL on page 5-103.

Two Discrete Lengths - This option allows you to decode only those codes containing two selected lengths. For example, if you select Code 39 Two Discrete Lengths, then scan 0, 2, 1, 4, only Code 39 symbols containing 2 or 14 characters are decoded. Numeric bar codes begin on page 5-101. If you make an error, or wish to change your selection, scan CANCEL on page 5-103.


Length Within Range - This option allows you to decode a code type within a specified range. For example to decode Code 39 symbols containing between 4 and 12 characters, first scan Code 39 Length Within Range. Then scan 0, 4, 1 and 2 (single digit numbers must always be preceded by a leading zero). Numeric bar codes begin on page 5-101. If you make an error, or wish to change your selection, scan CANCEL on page 5-103.

Any Length - Scanning this option allows you to decode Code 39 symbols containing any number of characters.

Parameter Menus

When enabled, this parameter checks the integrity of a Code 39 symbol to ensure it complies with specified algorithms.
Only those Code 39 symbols which include a modulo 43 check digit are decoded when this parameter is enabled.



Scan the appropriate bar code below to transmit the data with or without the check digit.

(ENABLE)

Parameter Menus

Scan the appropriate bar code below to enable or disable Code 39 Full ASCII.
When enabled, the ASCII character set assigns a code to letters, punctuation marks, numerals, and most control keystrokes on the keyboard.
The first 32 codes are non-printable and are assigned to keyboard control characters such as BACKSPACE and RETURN. The other 96 are called printable codes because all but SPACE and DELETE produce visible characters.
Code 39 Full ASCII interprets the bar code special character ($ + % /) preceding a Code 39 character and assigns an ASCII character value to the pair. For example, when Code 39 Full ASCII is enabled and a +B is scanned, it is interpreted as b, %J as ?, and $H emulates the keystroke BACKSPACE. Scanning ABC$M will output the keystroke equivalent of ABC ENTER. Refer to the ASCII table in Appendix A.
Code 39 Full ASCII and Trioptic Code 39 cannot be enabled simultaneously. If you get an error beep when enabling Code 39 Full ASCII, disable Trioptic Code 39 and try again.
The scanner does not autodiscriminate between Code 39 and Code 39 Full ASCII.


the barcode to be scanned when using Code 39 Full ASCII.

Scan the appropriate bar code below to enable or disable converting Code 39 to Code 32.

(ENABLE)

*DO NOT CONVERT CODE 39 TO CODE 32 (DISABLE)
Parameter Menus

Scan the appropriate bar code below to enable or disable the prefix character “A” to all Code 32 bar codes.
function.



Scan the appropriate bar code below to enable or disable Code 93.


Parameter Menus

Lengths for Code 93 may be set for any length, one or two discrete lengths, or lengths within a specific range. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.
One Discrete Length - This option allows you to decode only those codes containing a selected length. For example, if you select Code 93 One Discrete Length, then scan 1, 4, only Code 93 symbols containing 14 characters are decoded. Numeric bar codes begin on page 5-101. If you make an error, or wish to change your selection, scan CANCEL on page 5-103.

Two Discrete Lengths - This option allows you to decode only those codes containing two selected lengths. For example, if you select Code 93 Two Discrete Lengths, then scan 0, 2, 1, 4, only Code 93 symbols containing 2 or 14 characters are decoded. Numeric bar codes begin on page 5-101. If you make an error, or wish to change your selection, scan CANCEL on page 5-103.


Length Within Range - This option allows you to decode a code type within a specified range. For example to decode Code 93 symbols containing between 4 and 12 characters, first scan Code 93 Length Within Range. Then scan 0, 4, 1 and 2 (single digit numbers must always be preceded by a leading zero). Numeric bar codes begin on page 5-101. If you make an error, or wish to change your selection, scan CANCEL on page 5-103.

Any Length - Scanning this option allows you to decode Code 93 symbols containing any number of characters.

Parameter Menus

Scan the appropriate bar code below to enable or disable Interleaved 2 of 5.



Lengths for I 2 of 5 may be set for any length, one or two discrete lengths, or lengths within a specific range. The length of a code refers to the number of characters (i.e., human readable characters) the code contains and includes check digits.
One Discrete Length - This option allows you to decode only those codes containing a selected length. For example, if you select I 2 of 5 One Discrete Length, then scan 1, 4, the only I 2 of 5 symbols decoded are those containing 14 characters. Numeric bar codes begin on page 5-101. If you make an error, or wish to change your selection, scan CANCEL on page 5-103.

I 2 of 5 - ONE DISCRETE LENGTH
Two Discrete Lengths - This option allows you to decode only those codes containing two selected lengths. For example, if you select I 2 of 5 Two Discrete Lengths, then scan 0, 2, 1, 4, the only I 2 of 5 symbols decoded are those containing 2 or 14 characters. Numeric bar codes begin on page 5-101. If you make an error, or wish to change your selection, scan CANCEL on page 5-103.

I 2 of 5 - TWO DISCRETE LENGTHS
Parameter Menus

Length Within Range - This option allows you to decode a code type within a specified range. For example to decode I 2 of 5 symbols containing between 4 and 12 characters, first scan I 2 of 5 Length Within Range. Then scan 0, 4, 1 and 2 (single digit numbers must always be preceded by a leading zero). Numeric bar codes begin on page 5-101. If you make an error, or wish to change your selection, scan CANCEL on page 5-103.

I 2 of 5 - LENGTH WITHIN RANGE
Any Length - Scanning this option allows you to decode I 2 of 5 symbols containing any number of characters.

I 2 of 5 - ANY LENGTH

When enabled, this parameter checks the integrity of an I 2 of 5 symbol to ensure it complies with a specified algorithm, either USS (Uniform Symbology Specification), or OPCC (Optical Product Code Council).



Parameter Menus

Scan the appropriate bar code below to transmit the data with or without the check digit.

TRANSMIT I 2 of 5 CHECK DIGIT

*DO NOT TRANSMIT I 2 of 5 CHECK DIGIT (DISABLE)

This parameter converts a 14 character I 2 of 5 code into EAN-13, and transmits to the host as EAN-13. In order to accomplish this, the I 2 of 5 code must be enabled, one length must be set to 14, and the code must have a leading zero and a valid EAN-13 check digit.

CONVERT I 2 of 5 to EAN-13

*DO NOT CONVERT I 2 of 5 to EAN-13 (DISABLE)
Parameter Menus

Scan the appropriate bar code below to enable or disable Discrete 2 of 5.
*DISABLE DISCRETE 2 OF 5

Lengths for D 2 of 5 may be set for any length, one or two discrete lengths, or lengths within a specific range. The length of a code refers to the number of characters (i.e., human readable characters) the code contains, and includes check digits.
One Discrete Length - This option allows you to decode only those codes containing a selected length. For example, if you select D 2 of 5 One Discrete Length, then scan 1, 4, the only D 2 of 5 symbols decoded are those containing 14 characters. Numeric bar codes begin on page 5-101. If you make an error, or wish to change your selection, scan CANCEL on page 5-103.

D 2 of 5 - ONE DISCRETE LENGTH
Two Discrete Lengths - This option allows you to decode only those codes containing two selected lengths. For example, if you select D 2 of 5 Two Discrete Lengths, then scan 0, 2, 1, 4, the only D 2 of 5 symbols decoded are those containing 2 or 14 characters. Numeric bar codes begin on page 5-101. If you make an error, or wish to change your selection, CANCEL on page 5-103.

D 2 of 5 - TWO DISCRETE LENGTHS
Parameter Menus

Length Within Range - This option allows you to decode a code type within a specified range. For example to decode D 2 of 5 symbols containing between 4 and 12 characters, first scan D 2 of 5 Length Within Range. Then scan 0, 4, 1 and 2 (single digit numbers must always be preceded by a leading zero). Numeric bar codes begin on page 5-101. If you make an error, or wish to change your selection, scan CANCEL on page 5- 103.

D 2 of 5 - LENGTH WITHIN RANGE
Any Length - Scanning this option allows you to decode D 2 of 5 symbols containing any number of characters.

D 2 of 5 - ANY LENGTH

Scan the appropriate bar code below to enable or disable Codabar.


Parameter Menus

Lengths for Codabar may be set for any length, one or two discrete lengths, or lengths within a specific range. The length of a code refers to the number of characters (i.e., human readable characters) the code contains. It also includes any start or stop characters.
One Discrete Length - This option allows you to decode only those codes containing a selected length. For example, if you select Codabar One Discrete Length, then scan 1, 4, the only Codabar symbols decoded are those containing 14 characters. Numeric bar codes begin on page 5-101. If you make an error, or wish to change your selection, scan CANCEL on page 5-103.

Two Discrete Lengths - This option allows you to decode only those codes containing two selected lengths. For example, if you select Codabar Two Discrete Lengths, then scan 0, 2, 1, 4, the only Codabar symbols decoded are those containing 2 or 14 characters. Numeric bar codes begin on page 5-101. If you make an error, or wish to change your selection, scan CANCEL on page 5-103.


Length Within Range - This option allows you to decode a code type within a specified range. For example to decode Codabar symbols containing between 4 and 12 characters, first scan Codabar Length Within Range. Then scan 0, 4, 1 and 2 (single digit numbers must always be preceded by a leading zero). Numeric bar codes begin on page 5-101. If you make an error, or wish to change your selection, scan CANCEL on page 5- 103.

Any Length - Scanning this option allows you to decode Codabar symbols containing any number of characters.

Parameter Menus

If enabled, this parameter strips the start and stop characters and inserts a space after the first, fifth, and tenth characters of a 14-character Codabar symbol.



If enabled, this parameter strips the start and stop characters from a decoded Codabar symbol.


Parameter Menus

Scan the appropriate bar code below to enable or disable MSI Plessey.



Lengths for MSI Plessey may be set for any length, one or two discrete lengths, or lengths within a specific range. The length of a code refers to the number of characters (i.e., human readable characters) the code contains, and includes check digits.
One Discrete Length - This option allows you to decode only those codes containing a selected length. For example, if you select MSI Plessey One Discrete Length, then scan 1, 4, the only MSI Plessey symbols decoded are those containing 14 characters. Numeric bar codes begin on page 5-101. If you make an error, or wish to change your selection, scan CANCEL on page 5-103.

Two Discrete Lengths - This option allows you to decode only those codes containing two selected lengths. For example, if you select MSI Plessey Two Discrete Lengths, then scan 0, 2, 1, 4, the only MSI Plessey symbols decoded are those containing 2 or 14 characters. Numeric bar codes begin on page 5-101. If you make an error, or wish to change your selection, scan CANCEL on page 5-103.

Parameter Menus

Length Within Range - This option allows you to decode a code type within a specified range. For example to decode MSI Plessey symbols containing between 4 and 12 characters, first scan MSI Plessey Length Within Range. Then scan 0, 4, 1 and 2 (single digit numbers must always be preceded by a leading zero). Numeric bar codes begin on page 5-101. If you make an error, or wish to change your selection, scan CANCEL on page 5-103.

Any Length - Scanning this option allows you to decode MSI Plessey symbols containing any number of characters.
codes.


These check digits at the end of the bar code verify the integrity of the data. At least one check digit is always required. Check digits are not automatically transmitted with the data.


Parameter Menus

Scan the appropriate bar code below to transmit the data with or without the check digit.

(ENABLE)


When the two MSI Plessey check digits option is selected, an additional verification is required to ensure integrity. Either of the two following algorithms may be selected.


Parameter Menus

A code ID character identifies the code type of a scanned bar code. This may be useful when the scanner is decoding more than one code type. The code ID character precedes the decoded symbol.
The user may select no code ID character, a Symbol Code ID character, or an AIM Code ID character. The Symbol Code ID characters are listed below; see Appendix A, Bar Code Information for AIM Identifiers.
B = Code 39
D = Code 128
E = Code 93
F = Interleaved 2 of 5
G = Discrete 2 of 5, or Discrete 2 of 5 IATA
J = MSI Plessey
L = Bookland EAN
M = Trioptic Code 39
N = Coupon Code
C = Codabar




Parameter Menus

This parameter allows a pause to be inserted at any point in the data transmission. Pauses are set by scanning the bar code below followed by a two digit number (i.e. two bar codes), and are measured in 1/10 second intervals. For example, scanning bar codes “0” and “1” inserts a 1/10 second pause; “0” and “5” gives you a 1/2 second delay. Numeric bar codes begin on page 5-101. If you make an error, or wish to change your selection, scan CANCEL on page 5-103.


Baud Rate
Baud rate is the number of bits of data transmitted per second. The scanner's baud rate setting should match the data rate setting of the host device. If not, data may not reach the host device or may reach it in distorted form.



Parameter Menus






A parity check bit is the most significant bit of each ASCII coded character. Select the parity type according to host device requirements.
If you select ODD parity, the parity bit has a value 0 or 1, based on data, to ensure that an odd number of 1 bits are contained in the coded character.

If you select EVEN parity, the parity bit has a value 0 or 1, based on data, to ensure that an even number of 1 bits are contained in the coded character.

Parameter Menus

Select MARK parity and the parity bit is always 1.

Select SPACE parity and the parity bit is always 0.

If no parity is required, select NONE.


Select whether or not the parity, framing, and overrun of received characters are checked. The type of parity used is selectable through the PARITY parameter.


Parameter Menus

The data interface consists of an RS-232C port. The port has been designed to operate either with or without the hardware handshaking lines, RTS, Request to Send, and CTS, Clear to Send.
If Standard RTS/CTS handshaking is selected, scan data is transmitted according to the following sequence:
During the transmission of data, the CTS line should be asserted. If CTS is deasserted for more than 50 ms between characters, the transmission is aborted, the scanner sounds a transmission error, and the data is discarded.
If the above communications sequence fails, the scanner issues an error indication. In this case, the data is lost and must be rescanned.
If Hardware Handshaking and Software Handshaking are both enabled, Hardware Handshaking will take precedence.
is an 8 ms delay for the information to travel between the host and the scanner. If this setup is necessary, scan the Intercharacter Delay bar code on page 5-93 and set the delay for 10 ms or more.

Scan the bar code below if no Hardware Handshaking is desired.

Scan the bar code below to select Standard RTS/CTS Hardware Handshaking.

When RTS/CTS Option 1 is selected, the cradle asserts RTS before transmitting and ignores the state of CTS. The scanner deasserts RTS when the transmission is complete.

Parameter Menus

When Option 2 is selected, RTS is always high or low (user-programmed logic level). However, the scanner waits for CTS to be asserted before transmitting data. If CTS is not asserted within two seconds (default), the scanner issues an error indication and discards the data.

When Option 3 is selected, the scanner asserts RTS prior to any data transmission, regardless of the state of CTS. The scanner waits up to two seconds (default) for CTS to be asserted. If CTS is not asserted during this time, the scanner issues an error indication and discards the data. The scanner deasserts RTS when transmission is complete.

Software Handshaking
This parameter offers control of the data transmission process in addition to, or instead of, that offered by hardware handshaking. There are five options.
If Software Handshaking and Hardware Handshaking are both enabled, Hardware Handshaking takes precedence.
When this option is selected, data is transmitted immediately.


When this option is selected, after transmitting data, the cradle expects either an ACK, Acknowledge, or NAK, Negative Acknowledge, response from the host. Whenever a NAK is received, the cradle transmits the same data again and waits for either an ACK or NAK. After three unsuccessful attempts to send data when NAKs are received, the cradle issues an error indication and discards the data.
The cradle waits up to the programmable Host Serial Response Time-out to receive an ACK or NAK. If the cradle does not get a response in this time, it issues an error indication and discards the data. There are no retries when a time-out occurs.

ENQ
When this option is selected, the cradle waits for an ENQ, Enquiry, character from the host before transmitting data. If an ENQ is not received within two seconds, the cradle issues an error indication and discards the data. The host must transmit an ENQ character at least every two seconds to prevent transmission errors.

ACK/NAK with ENQ
This combines the two previous options.

Parameter Menus · ACK/NAK with ENQ

An XOFF, Transmit Off, character turns the scanner transmission off until the scanner receives an XON, Transmit On, character. There are two situations for XON/XOFF:

Host Serial Response Time-out
This parameter specifies how long the scanner waits for an ACK, NAK or CTS before determining that a transmission error has occurred. This only applies when in one of the ACK/NAK Software Handshaking modes, or RTS/CTS Hardware Handshaking option.
The delay period can range from 0.0 to 9.9 seconds in 0.1 second increments. After scanning the bar code below, scan two numeric bar codes beginning on page 5-101. If you make an error, or wish to change your selection, scan CANCEL on page 5-103.


Scan the appropriate bar code below to set the idle state of the Serial Host RTS line. Choose LOW RTS line state or HIGH RTS line state.


Parameter Menus

The stop bit(s) at the end of each transmitted character marks the end of transmission of one character and prepares the receiving device for the next character in the serial data stream. The number of stop bits (one or two) selected depends on the number the receiving terminal is programmed to accommodate. Set the number of stop bits to match host device requirements.


ASCII Format
This parameter allows the cradle to interface with devices requiring a 7-bit or 8-bit ASCII protocol.



Select the intercharacter delay option matching host requirements. The intercharacter delay gives the host system time to service its receiver and perform other tasks between characters. The delay period can range from no delay to 99 ms in 1 ms increments (if you are using a cradle and RTS/CTS handshaking, the delay period can range from 5 ms to 99 ms). After scanning the bar code below, scan two bar codes beginning on page 5-101 to set the desired time-out. If you make an error, or wish to change your selection, scan CANCEL on page 5-103.

MCL-Net Parameters
MCL-Net Baud Rate
Baud rate is the number of bits of data transmitted per second. Scan the appropriate bar code below to set the MCL-Net baud rate. The default baud rate is 38400.

Parameter Menus

BAUD RATE 2400

BAUD RATE 9600
BAUD RATE 19200
*BAUD RATE 38400
Parameter Menus

Scan the appropriate bar code below to set the MCL-Net Hex addressing mode. The default mode is Disabled.
MCL-NET HEX ADDRESSING ENABLED

Scan the following barcode, followed by 3 digits from the numeric barcode section (starting on page 5-101), to set the address of the scanner (scanner ID).
The number of scanner addresses (scanner ID’s) varies with the selected communication protocol.

MCL-Net Transmit Retries
Scan the following barcode, followed by 2 digits from the numeric barcode section (starting on page 5-101), to define the number of retries in the range 1 to 10.

MCL-Net Frame Timeout
Scan the following barcode, followed by 2 digits from the numeric barcode section (starting on page 5-101), to define the amount of time to wait for an ACK or NAK from the host before retransmitting. The timeout is in 100 ms increments in the range 100 ms to 3000 ms.

Parameter Menus


Select the type of beep for the scanner. This parameter is useful when two or more systems are installed in proximity of each other. Unique patterns can be set up to distinguish each system’s receipt of bar code data.

The P370 ALR (Long Range) scanner has an aiming feature which allows the positioning of the laser beam when scanning bar codes. Aiming mode and Aiming duration can be set using the bar codes below. You cannot program this feature into the standard range P370 scanner.
There are two Aiming options supported by the Phaser ALR cordless scanner, trigger pull to scan (default) and trigger release to scan.
When you pull the trigger, the aim dot will be active for a user-selectable duration of time. After this time, the aiming dot automatically turns into a standard laser scanning beam for a full decode session. After the aiming dot turns into a scanning beam, the laser will stay on until the user-selectable laser-on timeout occurs, a decode occurs, or the trigger is released. If the trigger is released during the aim mode, the laser shut off and no decode session occurs.
³ 2 0 5 1 B 0 0 *Trigger Pull to Scan (Default)
When you pull the trigger, the aiming dot will appear. The aiming dot remains present while the trigger is pulled or until a 60 second timeout occurs. When the trigger is released, the aiming dot turns into a standard laser scanning beam for a full decode session. The laser stays on until a decode occurs or until the user-selectable laser-on timeout occurs. If the trigger is pulled again while in a decode session, the scanner returns to its aiming mode.
Trigger Release to Scan
Parameter Menus

When the scanner is in Trigger Pull to Scan mode (default mode), Aim Duration sets the amount of time the aiming dot is seen before turning into a scanning beam. This parameter has no affect when the scanner is in the Trigger Release to Scan mode.
The Aim Duration is programmable in 0.1 second increments, from 0 to 9.9 seconds. If set to 0, no aiming pattern appears before a decode session. The default value is 0.8 seconds.
To set an aim duration, scan the barcode below. Then, scan two numeric barcodes, beginning on page 5-101, that correspond to the desired aim duration. Durations less than 1.0 second must have a leading zero. For example, to set an aim duration of 0.5 seconds, scan the barcode below, followed by the '0' and the '5' barcodes. If you make an error or wish to change your selection, scan the CANCEL barcode on page 5-103.
Aim Duration

For parameters requiring specific numeric values, scan the appropriately numbered bar code(s).
Parameter Menus


Cancel
If you make an error, or wish to change your selection, scan the bar code below.
Parameter Menus



UCC/EAN-128
UCC/EAN-128 is a convention for printing data fields with standard Code 128 bar code symbols. UCC/EAN-128 symbols are distinguished by a leading FNC 1 character as the first or second character in the symbol. Other FNC 1 characters are used to delineate fields.
When EAN-128 symbols are read, they are transmitted after special formatting strips off the leading FNC 1 character and replaces other FNC 1 characters with the ASCII 29 GS control character.
When AIM symbology identifiers are transmitted, the modifier character indicates the position of the leading FNC 1 character according to AIM guidelines. For example, ]c1 indicates a UCC/EAN-128 symbol with a leading FNC1 character.
Standard Code 128 bar codes which do not have a leading FNC 1 may still be used, but are not encoded according to the EAN-128 convention. Standard Code 128 and UCC/EAN- 128 may be mixed in an application. The scanner autodiscriminates between these symbols and can enable or disable one or both code types via bar code menus. The following table indicates the behavior of the scanner in each of the four possible parameter settings.

UCC/EAN-128 Effect and Example
Disable Disable No Code 128 symbols can be read.
Disable Enable Read only symbols with leading FNC 1.
Examples: FNC1ABCDFNC1E will be read as ABCD29E AFNC1BCDFNC1E will be read as ABCD29E FNC1FNC1ABCDFNC1E will be read as ABCD29E ABCDFNC1E can not be read ABCDE can not be read
Enable Disable Read only symbols without leading FNC 1.
Examples: FNC1ABCDFNC1E can not be read AFNC1BCDFNC1E can not be read FNC1FNC1ABCDFNC1E can not be read ABCDFNC1E will be read as ABCD29E ABCDE will be read as ABCDE
Enable Enable Read both types of symbols.
Examples: FNC1ABCDFNC1E will be read as ABCD29E AFNC1BCDFNC1E will be read as ABCD29E FNC1FNC1ABCDFNC1E will be read as ABCD29E ABCDFNC1E will be read as ABCD29E ABCDE will be read as ABCDE
Standard Code 128

Each AIM Code Identifier contains the three-character string ]cm where:
] = Flag Character (ASCII 93) c = Code Character (see Table A-2) m = Modifier Character (see Table A-3)
Code Character Code Type
I Interleaved 2 of 5
S D2 of 5, IATA 2 of 5
X Bookland EAN, Code 39 Trioptic, Coupon Code

The modifier character is the sum of the applicable option values based on the following table.
Code Type Option Value Option
Code 39 0 No check character or Full ASCII processing.
1 Reader has checked one check character.
3 Reader has checked and stripped check character.
4 Reader has performed Full ASCII character conversion.
5 Reader has performed Full ASCII character conversion and checked one check character.
7 Reader has performed Full ASCII character conversion and checked and stripped check character.
Example: A Full ASCII bar code with check character W, A+I+MI+DW, is transmitted as ]A7AimId where 7 = (3+4).
Trioptic Code 39 0 No option specified at this time. Always transmit 0.
Code 128 0 Standard data packet, no Function code 1 in first symbol position.
1 Function code 1 in first symbol character position.
2 Function code 1 in second symbol character position.
Example: A Code (EAN) 128 bar code with Function 1 character in the first position, FNC1 Aim Id is transmitted as ]C1AimId
I 2 of 5 0 No check digit processing.
1 Reader has validated check digit.
3 Reader has validated and stripped check digit.
Example: An I 2 of 5 bar code without check digit, 4123, is transmitted as ]I04123

Code Type Option Value Option
Codabar 0 No check digit processing.
1 Reader has checked check digit.
3 Reader has stripped check digit before transmission.
Code 93 0 No options specified at this time. Always transmit 0.
MSI Plessey 0 Single check digit checked.
1 Two check digits checked.
2 Single check digit verified and stripped before transmission.
3 Two check digits verified and stripped before transmission.
Example: An MSI Plessey bar code 4123, with a single check digit checked, is transmitted as ]M04123
D 2 of 5 0 No options specified at this time. Always transmit 0.
UPC/EAN 0 Standard packet in full EAN country code format, which is 13 digits for UPC-A and UPC-E (not including supplemental data).
1 Two-digit supplement data only.
2 Five-digit supplement data only.
4 EAN-8 data packet.
Bookland EAN 0 No options specified at this time. Always transmit 0.
Bar Code Information

According to AIM standards, a UPC with supplemental bar code is transmitted in one of the following formats:
]E0 (UPC chars) (terminator) ]E2 (supplemental) (terminator) or
]E2 (supplemental) (terminator) ]E0 (UPC chars) (terminator)
In the scanner, however, the format is changed to:
]E0 (UPC chars) ]E2 (supplemental)
Therefore, a UPC with two supplemental characters, 01234567890510, is transmitted to the host as a 21-character string, ]E00012345678905]E110.
Code Type Symbol Identifier
Interleaved 2 of 5 F
Discrete 2 of 5, D 2 of 5 IATA G
Trioptic Code 39 M

Code 39 Encode Char.
Code 39 Encode Char
1001 $A CTRL A 1025 $Y CTRL Y
1002 $B CTRL B 1026 $Z CTRL Z
1003 $C CTRL C 1027 %A CTRL [
1004 $D CTRL D 1028 %B CTRL \
1005 $E CTRL E 1029 %C CTRL ]
1006 $F CTRL F 1030 %D CTRL 6
1007 $G CTRL G 1031 %E CTRL -
1008 $H CTRL H 1032 Space Space
1010 $J CTRL J 1034 /B ‘
1011 $K CTRL K 1035 /C #
1012 $L CTRL L 1036 /D $
1013 $M CTRL M 1037 /E %
1014 $N CTRL N 1038 /F &
1015 $O CTRL O 1039 /G ‘
1016 $P CTRL P 1040 /H (
1017 $Q CTRL Q 1041 /I )
1018 $R CTRL R 1042 /J *
1019 $S CTRL S 1043 /K +
1020 $T CTRL T 1044 /L ,
1021 $U CTRL U 1045 - -
1022 $V CTRL V 1046 . .
A-7

Code 39 Encode Char.
Code 39 Encode Char
1049 1 1 1074 J J
1050 2 2 1075 K K
1051 3 3 1076 L L
1052 4 4 1077 M M
1053 5 5 1078 N N
1054 6 6 1079 O O
1055 7 7 1080 P P
1056 8 8 1081 Q Q
1057 9 9 1082 R R
1058 /Z : 1083 S S
1059 %F ; 1084 T T
1060 %G < 1085 U U
1061 %H = 1086 V V
1062 %I > 1087 W W
1063 %J ? 1088 X X
1064 %V @ 1089 Y Y
1065 A A 1090 Z Z
1066 B B 1091 %K [
1067 C C 1092 %L \
1068 D D 1093 %M ]
1069 E E 1094 %N ^
1070 F F 1095 %O _
1071 G G 1096 %W ‘
1072 H H 1097 +A a

Code 39 Encode Char.
Code 39 Encode Char
1098 +B b 1113 +Q q
1099 +C c 1114 +R r
1100 +D d 1115 +S s
1101 +E e 1116 +T t
1102 +F f 1117 +U u
1103 +G g 1118 +V v
1104 +H h 1119 +W w
1105 +I i 1120 +X x
1106 +J j 1121 +Y y
1107 +K k 1122 +Z z
1108 +L l 1123 %P {
1109 +M m 1124 %Q |
1110 +N n 1125 %R }
1111 +O o 1126 %S ~
1112 +P p 1127 Undefined

ALT Keys Keystroke ALT Keys Keystroke ALT Keys Keystroke
2064 ALT 2 2075 ALT K 2086 ALT V
2065 ALT A 2076 ALT L 2087 ALT W
2066 ALT B 2077 ALT M 2088 ALT X
2067 ALT C 2078 ALT N 2089 ALT Y
2068 ALT D 2079 ALT O 2090 ALT Z
2069 ALT E 2080 ALT P 2091 ALT [
2070 ALT F 2081 ALT Q 2092 ALT \
2071 ALT G 2082 ALT R 2093 ALT ]
2072 ALT H 2083 ALT S 2094 ALT 6
2073 ALT I 2084 ALT T 2095 ALT -
Misc. Key Keystroke Misc. Key Keystroke Misc. Key Keystroke
3002 PA 2 3010 CMD 8 3018 1/2
3003 CMD 1 3011 CMD 9 3019 ¶
3004 CMD 2 3012 CMD 10 3020 §
3005 CMD 3 3013 ¥ 3021 |
3006 CMD 4 3014 £ 3022 0/00
3007 CMD 5 3015 ¤
3008 CMD 6 3016 ¬
A-10

PF Keys Keystroke PF Keys Keystroke PF Keys Keystroke
4001 PF 1 4009 PF 9 4017 PF 17
4002 PF 2 4010 PF 10 4018 PF 18
4003 PF 3 4011 PF 11 4019 PF 19
4004 PF 4 4012 PF 12 4020 PF 20
4005 PF 5 4013 PF 13 4021 PF 21
4006 PF 6 4014 PF 14 4022 PF 22
4007 PF 7 4015 PF 15 4023 PF 23
4008 PF 8 4016 PF 16 4024 PF 24
F Keys Keystroke F Keys Keystroke F Keys Keystroke
5001 F 1 5014 F 14 5027 F 27
5002 F 2 5015 F 15 5028 F 28
5003 F 3 5016 F 16 5029 F 29
5004 F 4 5017 F 17 5030 F 30
5005 F 5 5018 F 18 5031 F 31
5006 F 6 5019 F 19 5032 F 32
5007 F 7 5020 F 20 5033 F 33
5008 F 8 5021 F 21 5034 F 34
5009 F 9 5022 F 22 5035 F 35
5010 F 10 5023 F 23 5036 F 36
5011 F 11 5024 F 24 5037 F 37
5012 F 12 5025 F 25 5038 F 38
5013 F 13 5026 F 26 5039 F 39
Bar Code Information

6042 * 6049 1 6056 8
6043 + 6050 2 6057 9
6044 Undefined 6051 3 6058 Enter
6045 - 6062 4 6059 Num Lock
6046 . 6063 5 6060 00
6047 / 6064 6
6048 0 6065 7
7001 Break 7008 Backspace 7015 Up Arrow
7002 Delete 7009 Tab 7016 Dn Arrow
7003 Pg Up 7010 Print Screen 7017 Left Arrow
7004 End 7011 Insert 7018 Right Arrow
7005 Pg Dn 7012 Home 7019 Back Tab
7006 Pause 7013 Enter
7007 Scroll Lock 7014 Escape

The Phaser P470/P370 RF scanner is shipped from the factory with a pre-installed default application. This fully functional application allows the scanner to be used “out of the box”. If you need to load your own application into the scanner, the “Automatic Project Download” feature will simplify the process.
When the default application is running, and the scanner is placed into its paired cradle, the scanner will query the MCL-Link host for data in a file named “PHASER.CFG”. The scanner will use the information in this file to find the project directory which the user wishes to have loaded into the scanner, and will then execute the PROJECT.CMD” script which exists in the directory. This script will automatically download all program and data files relevant to the project to the scanner and will reset the scanner making it ready to run the user’s application.
In order to utilize this mechanism, the user needs only generate the PHASER.CFG file and place it in the directory specified in the MCL-Link setup screen as the “General path for data files”. Any text editor may be used to create this file; the contents of the file are as follows:
X|
The X| at the beginning of the line are required for the MCL-Net CR command to recognize this file and read the data. The path name should include the entire path hierarchy. Also, all backslashes (\) in the path name should be replaced with the string “\5C”, so that the MCL code running on the scanner does not inadvertently convert part of the path name to the equivalent Hex Character.
An example PHASER.CFG file is shown below:
x|c:\5Cmcl-p460\5Cdesigner\5Csample1.prj

The PROJECT.CMD file will be automatically generated by the MCL-Designer application.

Cordless Phaser RF Channels Per Country
The cordless Phaser scanner operates continuously on a single, programmable channel (frequency) between 2.402 GHz (channel 02) and 2.483 GHz (channel 83).
A maximum of 82 channels are available. Not all channels are available in all countries. If a channel is not legal to use in your country, an error beep will be heard instead of a successful warble.
See Table C-1 for a list of channel availability by Country.
operation in all countries listed in Table C-1, not all country configurations are available for order. Consult your local Symbol reseller for more information.
ARGENTINA 82 2 83
AUSTRALIA 82 2 83
AUSTRIA 82 2 83
BELGIUM 82 2 83
Country Total Channels · First Channel · Last Channel

BOLIVIA 82 2 83
BRAZIL 82 2 83
CANADA 82 2 83
CHILE 82 2 83
COLOMBIA 82 2 83
COSTARICA 82 2 83
CZECH REPUBLIC 82 2 83
DENMARK 82 2 83
DOMINICAN REPUBLIC 82 2 83
FINLAND 82 2 83
FRANCE 7 47 53
GERMANY 82 2 83
GREECE 82 2 83
GUATEMALA 82 2 83
HONDURAS 82 2 83
HONG KONG 82 2 83
HUNGARY 82 2 83
INDONESIA 82 2 83
ICELAND 82 2 83
IRELAND 82 2 83
ISRAEL 36 20 55
ITALY 82 2 83
JAPAN 80 2 81
KOREA 82 2 83
Country Total Channels · First Channel · Last Channel

LUXEMBOURG 82 2 83
MALAYSIA 82 2 83
MEXICO 32 52 83
NETHERLANDS 82 2 83
NEW ZEALAND 82 2 83
NICARAGUA 82 2 83
NORWAY 82 2 83
PERU 82 2 83
PHILIPPINES 82 2 83
POLAND 82 2 83
PORTUGAL 82 2 83
ROMANIA 82 2 83
RUSSIA 82 2 83
SAUDI ARABIA 82 2 83
SINGAPORE 37 47 83
SLOVENIA 82 2 83
SOUTH AFRICA 82 2 83
SPAIN 27 47 73
SWEDEN 82 2 83
SWITZERLAND 82 2 83
TAIWAN 80 2 81
THAILAND 82 2 83
TURKEY 82 2 83
UNITED ARAB EMIRATES 82 2 83

UNITED KINGDOM 82 2 83
URUGUAY 82 2 83
UNITED STATES (US) 82 2 83
VENEZUELA 82 2 83
Country Total Channels · First Channel · Last Channel

Introduction
This Appendix contains information on messages and error codes displayed on the scanner.
The scanner displays messages when certain actions are performed. If the scanner displays a message that is unfamiliar, contact the Symbol Support Center on page xi.
Unit Cradled Scanner is properly inserted in the cradle
Battery Temperature Out Of Range
Battery temperature is out of range. Contact a Symbol Support Center on page xi.
Pairing Unsuccessful Push ENTER & Try Again
The scanner has not been successfully paired with the base (cradle). Press ENTER and then try to pair the scanner and cradle again.
Failed to initiate download-Press ENTER
New firmware was not successfully downloaded to the device. This message can be displayed while downloading new firmware to either the scanner or base. Cycle power (power off then on) to the base and try again.
Message Description

Recharge Battery Battery is close to complete discharge. Recharge the battery
Scanning Transmission Range
A communication error will occur when the scanner, cradle or host fails to properly communicate. When a communication error occurs while using the default application, the scanner emits 4 beeps (LO HI LO HI) and displays a "Failed Communication" error message.
Failed Communication Error 015 Push ENTER
The three-digit error code on the scanner's screen indicates what type of communication problem has occurred. For example, error code 015 generally indicates the scanner is out of RF range, is not properly paired with the base, or the base may have lost power. For a complete list of error codes, see Table D-2.
Error Code Type Description
002 Serial Protocol Error RS-232 host does not recognize character(s) transmitted from scanner.
003 Serial Protocol Error Handshaking failure.
005 Serial Protocol Error Scanner does not recognize character(s) transmitted from RS-232 host.
008 SYNAPSE Error Synapse host does not recognize character(s) transmitted from scanner.
009 SYNAPSE Error Synapse transmission failed. Synapse cable may not be properly installed.
Message Description

Messages and Error Codes
Error Code Type Description
015 RF Communication Error
Scanner is out of range, not properly paired to a base or the base may have lost power.
016 RF Communication Error
The base to which the scanner is paired has been paired with another scanner.
017 RF Communication Error
Scanner is out of range.
018 MCL-Link Error A Synapse cable cannot communicate with MCL-Link. Reconnect to the host using an RS-232 cable and then cycle power (power off then on) to the base.
020 RF Communication Error
Previous RF transmission not yet complete.
021 Memory Allocation Error For repeated occurrence contact Customer Service.
024 RF Communication Error
The base is not responding. Cycle power (power off then on) to the base.
247 MCL-Link Error MCL-Link responded with a busy message.
249 MCL-Link Error MCL-Link rejected the command.
253 MCL-Link Error MCL-Link or 123Scan did not respond. The base may not be properly connected to the host. make sure the RS-232 cable is properly connected and the base is receiving power. If the problem persists, cycle power (power off then on) to the base.
display but are reported in System Variable 97 immediately after the execution of the offending command (SO, SI, NO or NI).



check digit algorithm 5-77 check digits 5-75 enable/disable 5-72 set lengths 5-73, 5-74 transmit check digit 5-76 numeric bar codes . . 5-101, 5-102, 5-103 pause duration 5-80 RS-232C parameters
C carriage return 3-17, 3-18 charge status indicator light 1-2 charge status LED indications 4-3 charging the battery 2-8, D-1 code identifier A-3 co-existence
phaser-to-phaser 2-8 Spectrum24 2-7 communication protocol 3-2, 3-8, 5-8
handshaking 5-89 set default 5-7 sleep time 5-15 system code 3-12 system menu 1-4, 3-7 transmit code ID character 5-78, 5-79 transmit "no read" 5-23 UPC-A/UPC-E
MCL-Net 3-8, 5-8, 5-9, 5-93 RS232 2-2, 3-8, 5-8, 5-10, 5-81 scan & transmit app 3-2, 3-8, 5-2, 5-8 Synapse 2-3, 3-8, 5-8 connecting to a host 2-1 cradle 1-2, 2-1
transmit check digit 5-33 UPC/EAN
charging in the cradle 2-9 description of basic operation . . . 1-2, 4-3 LED indicator status 4-3 pin outs 4-6 setting up the cradle 2-1, 2-6, 2-7
bookland EAN 5-30 convert EAN-8 to EAN-13 type . 5-40 convert UPC-E to UPC-A . . 5-37, 5-38 coupon code 5-43 EAN zero extend 5-39 EAN-8/EAN-13 5-29 enable/disable 5-28 security level 5-41, 5-42 supplemental redundancy 5-32 supplementals 5-31 UPC-A preamble 5-34 UPC-E preamble 5-35 UPC-E1 preamble 5-36 battery 1-2
D data formatting 3-17 dead zone 3-23 decode depth of field 3-24 decode options 5-23 decode symbologies/capability 4-4 Default Application 3-1
Scan and Transmit Application . . 3-2, 5-8 default settings 5-2
battery charge 2-8, 2-9, 4-7 battery temperature range message . . D-1 changing 4-2 changing/replacing 4-1 charging 2-9 checking battery charge level 3-14 beeper
resetting default application 3-10 resetting default scanning parameter . . 5-7 table of default parameters 5-2 default table 5-2 depth of field/decode zone 3-24 Dimensions 4-5 downloading
ADF rules 3-17 applications 3-9 automatic upgrade process B-1 durability 4-4
beeper indications 4-7 beeper operation 4-4 beeper tone 5-18 beeper volume 5-19 boot up the scanner 3-1, 3-27
Index-2

E eliminating repetitive scanning 3-4 ENABLE UPC-E1 5-28 error beep sequences 4-7 error codes 3-5, 4-7, D-2 error messages and codes D-1 Exit System Menu 3-16
loading system code 3-12
M maintenance 4-1 Manual Data Entry
alpha data 3-3, 3-26 decimal points 3-27 example keying in data 3-26 numeric data 3-3 maximum tilt angles 3-23 MCL Net 3-8, 5-8
F firmware version 3-7, 3-15 formatting data 3-17
baud rate 5-6, 5-93, 5-95 frame timeout 5-6, 5-97 hex addressing mode 5-6, 5-96 parameters 5-93 scanner address 5-6 transmit retries 5-6, 5-97 messages D-1
H hardware handshaking 5-86 humidity 4-4
N notational conventions ix numeric bar codes 5-101, 5-102 numeric data entry 3-2, 3-26
quick startup 1-3 introduction 1-1
access the system menu 3-7 alpha data entry 3-3 enabling/disabling the keypad 3-26 entering a blank space 3-27
O Operational parameters 5-1
P P370 ALR (see ALR) 5-99 pairing long range scanners 2-6 pairing the scanner and cradle 2-6 parameters
a dash 3-27 a decimal point 3-27 example keying in data 3-27 manually resetting the scanner . 3-1, 3-28 numeric data entry 3-2 operation and layout 3-26 quantity entry 3-4
clear an ADF rule 3-17 reset default application 3-10 set all defaults 5-7 table of default settings 5-2 pause duration 5-80 pin outs
L laser classification 4-5 LED status on cradle 4-3 loading
cradle 4-6 pitch 4-4 Power Detect Beep 5-20 print contrast minimum 4-4
loading base station code 3-13 loading new applications 3-9
Index · Index-3

Q quick startup instructions 1-3
clearing ADF rules 3-17 default application 3-10 default scanning parameters 5-7 set length
R reboot scanner 3-1, 3-28 Related Publication x resetting the scanner 3-1, 3-28 Returns to Application 3-16 RF
codabar 5-68 code 39 5-48 code 93 5-56 discrete 2 of 5 5-65 interleaved 2 of 5 5-59 MSI Plessey 5-73 Set Scanner ID 3-8 setup
optimizing RF performance 2-7 pairing scanner to cradle 2-6 RF channel 3-8, 5-13, C-1 RF communication errors . . 3-5, 3-28, D-1 RF retries 2-8, 5-13 roll tolerance 4-4 RS-232C 2-2, 3-8, 5-8, 5-10
quick startup instructions 1-3 sleep time 5-15 software version
see firmware version 3-7, 3-15 spare pairing bar code 2-6 specular reflection 3-23 stay awake 5-15 suffix values
ASCII format 5-92 baud rate 5-81, 5-82 check receive errors 5-85 hardware handshaking . . 5-86, 5-87, 5-88 host serial response time-out 5-90 host types 5-9 intercharacter delay 5-93 parity 5-83, 5-84 RTS line state 5-91 software handshaking . . . 5-88, 5-89, 5-90 stop bit select 5-92
Enter (carriage return) 3-18 Tab 3-20 symbol code identifier characters A-6 symbol support center xi Synapse connectivity 2-3, 3-8, 5-8 system code
bar code 3-12 system menu 3-7
S Scan and Transmit Application 3-2
accessing 3-7 Back To Main 3-8, 3-13, 3-14 Battery Check 3-14 exiting system menu 3-16 load new application 3-9 navigating the system menu 3-7 Set Contrast 3-8 set default application 3-10 Set Default Params 3-14 set RF channel 3-8 version 3-7, 3-15
communication protocol .3-2, 3-8, 5-2, 5-8 manual alphanumeric entry 3-2, 3-3 quantity entry 3-2, 3-4 scan repetition rate 4-4 scanner address 5-97 Scanner Decode Beep Type 5-98 scanner decode beep type 5-98 scanner emits transmit errors 3-28 scanner ID 3-8, 5-97 Scanning 3-2 scanning
T tab 3-20
eliminating repetition 3-4 service information x
set defaults · Index-4

technical specifications 4-4 temperature
unit cradled message 2-9, D-1 unpacking 2-1
battery D-1 operating 4-4 storage 4-4 transmit code ID character 5-78, 5-79 trigger pull to scan 5-99 trigger release to scan 5-99 troubleshooting 3-28
V version 3-7, 3-15
W wake up 3-2 working range 3-24
messages and error codes D-1
U UCC/EAN-128 A-1
Y yaw 4-4
Index · Index-5

Index-6

Tell Us What You Think...
We’d like to know what you think about this Manual. Please take a moment to fill out this questionnaire and fax this form to: (631) 738-3318, or mail to:
Symbol Technologies, Inc. One Symbol Plaza M/S B-4 Holtsville, NY 11742-1300 Attention: Technical Publications Manager
(please include revision level)
How familiar were you with this product before using this manual?
Very familiar Slightly familiar Not at all familiar
Did this manual meet your needs? If not, please explain. ___________________________________________________________ ___________________________________________________________
What topics need to be added to the index, if applicable?
What topics do you feel need to be better discussed? Please be specific
Thank you for your input—We value your comments.

Below is an index of Quick Startup Instructions to help get you up and going quickly. The index is listed in a step by step order beginning with step 1, Setting up the System.
Mandatory steps are designated by an asterisk (*). If an item has multiple pages referenced, the most important reference is in bold.
- RS-232 connection 2-2
- Synapse connection (keyboard wedge, USB, etc.) 2-3
- RF channel 3-8, 5-13, C-1
- Coexisting in Spectrum24 environments 2-7
- RS-232 baud rate 5-81
Symbol Technologies, Inc. One Symbol Plaza, Holtsville N.Y. 11742-1300
PRG Page
Wat de op het display getoonde foutcodes betekenen en hoe u ze wist.
| Code | Betekenis | Oplossing | |
|---|---|---|---|
| 002 | RS-232 host does not recognize character(s) transmitted from scanner. | p.192 | |
| 003 | Handshaking failure. | p.192 | |
| 005 | Scanner does not recognize character(s) transmitted from RS-232 host. | p.192 | |
| 008 | Synapse host does not recognize character(s) transmitted from scanner. | p.192 | |
| 009 | Synapse transmission failed. Synapse cable may not be properly installed. | p.192 |
Veelvoorkomende problemen, mogelijke oorzaken en oplossingen.
| Probleem | Mogelijke oorzaak | Oplossing | |
|---|---|---|---|
| General problem solving | • Check that the power supply is attached to the cradle. • Check for loose cable connections at the cradle, AC power supply, or host device. • Make sure the scanner and cradle have been successfully paired. • Check the scanner’s battery charge level. See Battery Check on page 3-14. • Make sure the device is programmed to read the type of bar code you want to scan. • Check the symbol to make sure it is not defaced. • Try scanning another similar symbol of the same code type. • Be sure you’re within the proper scanning decode range. • Make sure you are within the proper RF transmission range. • Cycle power (power off then on) to the base. • Reboot (reset) the scanner (hold down the ENTER key for about 30 seconds) and try scanning again. | p.58 | |
| The scanner emits error beeps after decoding a bar code. | • Check that the cradle is powered up and that it’s cable connections are secure. See Setting Up the Cradle on page 2-1. • Check that the scanner is successfully paired with the cradle. See Pairing the Scanner with the Cradle on page 2- 6. • Check that you are within transmitting range. See Communication Errors on page 3-5 and Appendix D, Messages and Error Codes. | p.58 | |
| The scanner does not scan the programming bar codes in this PRG. | • For MCL-Designer generated applications, put the scanner into “Scan Parameter” mode in the system menu (see Scan Parameters on page 3-14). • For the default application running on a previous version of firmware (Revision F or lower, such as E), put the scanner into “Scan Parameter” mode in the system menu (see Scan Parameters on page 3-14). For instructions on how to check the scanner’s firmware version, see Version on page 3-15. | p.59 | |
| The PC cannot download an application to the scanner. | • Check to make sure you are using an RS-232 cable. The application can not be downloaded to a scanner using a Synapse cable. • Make sure the scanner and cradle are successfully paired. • Check to make sure the power supply is connected to the base. • If the problem continues, cycle power to the base (powered off then on). | p.59 | |
| Received an 015 communication error while using a Synapse cable. | • The cables connected to the cradle were not connected in the correct sequence. Before power is applied to the cradle, the Synapse cable must be connected to the cradle AND the flying power lead plugged in. See Using A Synapse Cable on page 2-3 for more information | p.59 | |
| The P370 ALR scanner will not pair with a PL370 cradle. | • To pair a long range P370 ALR scanner with a PL370 cradle, attach the spare pairing bar code label to the cradle and scan the bar code. For additional information, see Pairing the Scanner with the Cradle on page 2-6. | p.59 | |
| The Scanner will not load my ADF rule. | • Software download to the scanner while the scanner is running the default application. • Check that the scanner is successfully paired with the cradle (see page 2-6). • Check that the cradle and PC are connected using an RS-232 cable. • Software download or scanning a bar code sheet while the scanner is running an MCL-Designer generated application • Erase the MCL-Designer application from the scanner’s memory by scanning the “Reset Default Application” bar code on page 3-10. • The default application is now reinstalled and an ADF rule can be loaded. | p.60 |