NL
Symbol Technologies logo
Officiële handleiding

Symbol Technologies P470

202 pagina's·1.7 MB·Scanner·PDF·EN
Symbol Technologies P470
Inhoudsopgave 203 secties About This Manual · Introduction · Chapter Descriptions · Notational Conventions · … TonenVerbergen
About This Manualp.11Introductionp.11Chapter Descriptionsp.11Notational Conventionsp.11Related Publicationsp.12Service Informationp.12Symbol Support Centerp.13Warrantyp.15Warranty Coverage and Procedurep.16Generalp.16Chapter 1 The P470/P370 RF Scannerp.17Introductionp.17Rechargeable Batteryp.18The Cradlep.18Quick Startup Instructionsp.19Commonly Used P470/P370 Programming Bar Codep.20Chapter 2 Set Upp.21Introductionp.21Unpackingp.21Setting Up the Cradlep.21Connecting to a Hostp.21Wall Mountingp.24Pairing the Scanner with the Cradlep.26Optimizing RF Performancep.27Mountingp.27Coexistence in Spectrum24 Environmentsp.27Phaser-to-Phaser Co-Existencep.28Charging the Batteryp.28Using the Cradlep.29Using the UBC 2000p.29Battery Chargep.29Chapter 3 Operationp.31Introductionp.31Default Applicationp.31Initial Powerupp.32Scan and Transmit Applicationp.32Eliminating Repetitive Scanningp.34Communication Errorsp.35RF Communication Errorsp.35Host / Cradle Communication Errorsp.36System Menup.37123Scanp.47Suffix Valuesp.48Scanningp.52Scan the Entire Symbolp.52Hold at an Anglep.53Decode Zonep.54Keypad Operationp.56Troubleshootingp.58Chapter 4 Maintenance And Specificationsp.61Introductionp.61Maintenancep.61Changing the Batteryp.61Removing the Batteryp.62Replacing the Batteryp.62Charge Status LED Indicationsp.63Technical Specificationsp.64Cradle Pin-outsp.66Beeper Indications / Default Application Error Codesp.67Chapter 5 Parameter Menusp.69Introductionp.69Operational Parametersp.69Set Default Parameterp.75Communication Protocolp.76Scan & Transmit Applicationp.76Host Typep.77RS-232C Host Typesp.77Host Response Timeoutp.80RF Channelp.81RF Retriesp.81Sleep Timep.83Decimal Separatorp.84Key Clickp.85Beeper Tonep.86Beeper Volumep.87Power Detect Beepp.88Beep After Good Decodep.89Laser On Timep.90Transmit “No Read” Messagep.91Linear Code Type Security Levelp.92Linear Security Level 1p.92Linear Security Level 2p.92Linear Security Level 3p.93Linear Security Level 4p.93Bi-directional Redundancyp.94Autodiscriminate Response Timep.95Enable/Disable UPC-E/UPC-A/UPC-E1p.96Enable/Disable EAN-8/EAN-13p.97Enable/Disable Bookland EANp.98Decode UPC/EAN Supplementalsp.99Decode UPC/EAN Supplemental Redundancyp.100Transmit UPC-A/UPC-E/UPC-E1 Check Digitp.101UPC-A Preamblep.102UPC-E Preamblep.103UPC-E1 Preamblep.104Convert UPC-E to UPC-Ap.105Convert UPC-E1 to UPC-Ap.106EAN-8 Zero Extendp.107Convert EAN-8 to EAN-13 Typep.108UPC/EAN Security Levelp.109UPC/EAN Security Level 0p.109UPC/EAN Security Level 1p.109UPC/EAN Security Level 2p.110UPC/EAN Security Level 3p.110UPC/EAN Coupon Codep.111Enable/Disable Code 128p.112Enable/Disable UCC/EAN-128p.113Lengths for Code 128p.113Enable/Disable Code 39p.114Enable/Disable Trioptic Code 39p.115Set Lengths for Code 39p.116Code 39 Check Digit Verificationp.118Transmit Code 39 Check Digitp.119Enable/Disable Code 39 Full ASCIIp.120Convert Code 39 to Code 32p.121Code 32 Prefixp.122Enable/Disable Code 93p.123Set Lengths for Code 93p.124Enable/Disable Interleaved 2 of 5p.126Set Lengths for Interleaved 2 of 5p.127I 2 of 5 Check Digit Verificationp.129Transmit I 2 of 5 Check Digitp.130Convert I 2 of 5 to EAN-13p.131Enable/Disable Discrete 2 of 5p.132Set Lengths for Discrete 2 of 5p.133Enable/Disable Codabarp.135Set Lengths for Codabarp.136CLSI Editingp.138NOTIS Editingp.139Enable/Disable MSI Plesseyp.140Set Lengths for MSI Plesseyp.141MSI Plessey Check Digitsp.143Transmit MSI Plessey Check Digitp.144MSI Plessey Check Digit Algorithmp.145Transmit Code ID Characterp.146Symbol Code ID Charactersp.146Pause Durationp.148RS-232C Parametersp.149Baud Ratep.149Baud Rate (Continued)p.150Parityp.151Parity (Continued)p.152Check Receive Errorsp.153Hardware Handshakingp.154Hardware Handshaking (Continued)p.155Hardware Handshaking (Continued)p.156Software Handshakingp.156Software Handshaking (Continued)p.157Software Handshaking (Continued)p.158Host Serial Response Time-outp.158RTS Line Statep.159Stop Bit Selectp.160ASCII Formatp.160Intercharacter Delayp.161MCL-Net Parametersp.161MCL-Net Baud Ratep.161MCL-Net Baud Rate (Continued)p.163MCL-Net Hex Addressing Modep.164Scanner Addressp.165MCL-Net Transmit Retriesp.165MCL-Net Frame Timeoutp.165Scanner Decode Beep Typep.166Long Range Scanning Bar Codesp.167Aim Modep.167Aim Durationp.168Numeric Bar Codesp.169Cancelp.171Appendix A Bar Code Informationp.173UCC/EAN-128p.173AIM Code Identifiersp.175Appendix B Automatic Project Downloadp.185Appendix C Radio Channelsp.187Cordless Phaser RF Channels Per Countryp.187Appendix D Messages and Error Codesp.191Introductionp.191Messagesp.191Communication Errorsp.192Scanning Transmission Rangep.192Indexp.195Numericsp.195Ap.195Bp.195Cp.196Dp.196Ep.197Fp.197Hp.197Ip.197Kp.197Lp.197Mp.197Np.197Op.197Pp.197Qp.198Rp.198Sp.198Tp.198Up.199Vp.199Wp.199Yp.199Quick Startup Instructionsp.202
Page 1 of the Symbol Technologies P470 user manual — Product Reference Guide
Pagina 1 · klik om te vergroten
Pagina 1

P470/P370 RF Scanners

Symbol Technologies P470 — P470/P370 RF Scanners diagram (page 1)
Afb. 1 · P470/P370 RF Scanners

Product Reference Guide

Page 2 of the Symbol Technologies P470 user manual
Pagina 2 · klik om te vergroten
Pagina 2
Page 2 of the Symbol Technologies P470 user manual
Page 3 of the Symbol Technologies P470 user manual — P470/P370 RF Scanner
Pagina 3 · klik om te vergroten
Pagina 3

P470/P370 RF Scanner

Product Reference Guide

72-38495-03 · Revision B · December 2001

Page 4 of the Symbol Technologies P470 user manual
Pagina 4 · klik om te vergroten
Pagina 4

© 2001 by Symbol Technologies, Inc. All rights reserved.

No part of this publication may be reproduced or used in any form, or by any electrical or mechanical means, without permission in writing from Symbol. This includes electronic or mechanical means, such as photocopying, recording, or information storage and retrieval systems. The material in this manual is subject to change without notice.

The software is provided strictly on an “as is” basis. All software, including firmware, furnished to the user is on a licensed basis. Symbol grants to the user a non-transferable and non-exclusive license to use each software or firmware program delivered hereunder (licensed program). Except as noted below, such license may not be assigned, sublicensed, or otherwise transferred by the user without prior written consent of Symbol. No right to copy a licensed program in whole or in part is granted, except as permitted under copyright law. The user shall not modify, merge, or incorporate any form or portion of a licensed program with other program material, create a derivative work from a licensed program, or use a licensed program in a network without written permission from Symbol. The user agrees to maintain Symbol’s copyright notice on the licensed programs delivered hereunder, and to include the same on any authorized copies it makes, in whole or in part. The user agrees not to decompile, disassemble, decode, or reverse engineer any licensed program delivered to the user or any portion thereof.

Symbol reserves the right to make changes to any software or product to improve reliability, function, or design.

Symbol does not assume any product liability arising out of, or in connection with, the application or use of any product, circuit, or application described herein.

No license is granted, either expressly or by implication, estoppel, or otherwise under any Symbol Technologies, Inc., intellectual property rights. An implied license only exists for equipment, circuits, and subsystems contained in Symbol products.

Symbol, Spectrum One, and Spectrum24 are registered trademarks of Symbol Technologies, Inc. Other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies and are hereby acknowledged.

Symbol Technologies, Inc. One Symbol Plaza Holtsville, New York 11742-1300 http://www.symbol.com

Page 5 of the Symbol Technologies P470 user manual — Chapter 2. Set Up
Pagina 5 · klik om te vergroten
Pagina 5

Contents

About This Manual

Introduction ix Chapter Descriptions ix Notational Conventions ix Related Publications x Service Information x

Symbol Support Center xi Warranty xiii

Warranty Coverage and Procedure xiv General xiv

Chapter 1. The P470/P370 RF Scanner

Introduction 1-1 Rechargeable Battery 1-2 The Cradle 1-2 Quick Startup Instructions 1-3 Commonly Used P470/P370 Programming Bar Code 1-4

Chapter 2. Set Up

Introduction 2-1 Unpacking 2-1 Setting Up the Cradle 2-1

Connecting to a Host 2-1 Wall Mounting 2-4 Pairing the Scanner with the Cradle 2-6 Optimizing RF Performance 2-7

Mounting 2-7 Coexistence in Spectrum24 Environments 2-7 Phaser-to-Phaser Co-Existence 2-8

Page 6 of the Symbol Technologies P470 user manual — Chapter 5. Parameter Menus
Pagina 6 · klik om te vergroten
Pagina 6

Charging the Battery 2-8

Using the Cradle 2-9 Using the UBC 2000 2-9 Battery Charge 2-9

Chapter 3. Operation

Introduction 3-1 Default Application 3-1

Initial Powerup 3-2 Scan and Transmit Application 3-2 Eliminating Repetitive Scanning 3-4 Communication Errors 3-5

RF Communication Errors 3-5 Host / Cradle Communication Errors 3-6 System Menu 3-7 123Scan 3-17 Suffix Values 3-18 Scanning 3-22

Scan the Entire Symbol 3-22 Hold at an Angle 3-23 Decode Zone 3-24 Keypad Operation 3-26 Troubleshooting 3-29

Chapter 4. Maintenance And Specifications

Introduction 4-1 Maintenance 4-1 Changing the Battery 4-1

Removing the Battery 4-2 Replacing the Battery 4-2 Charge Status LED Indications 4-3 Technical Specifications 4-4 Cradle Pin-outs 4-6 Beeper Indications / Default Application Error Codes 4-7

Chapter 5. Parameter Menus

Introduction 5-1 Operational Parameters 5-1 Set Default Parameter 5-7 Communication Protocol 5-8

Scan & Transmit Application 5-8

Page 7 of the Symbol Technologies P470 user manual
Pagina 7 · klik om te vergroten
Pagina 7

Host Type 5-9

RS-232C Host Types 5-9 Host Response Timeout 5-12 RF Channel 5-13 RF Retries 5-13 Sleep Time 5-15 Decimal Separator 5-16 Key Click 5-17 Beeper Tone 5-18 Beeper Volume 5-19 Power Detect Beep 5-20 Beep After Good Decode 5-21 Laser On Time 5-22 Transmit “No Read” Message 5-23 Linear Code Type Security Level 5-24

Linear Security Level 1 5-24 Linear Security Level 2 5-24 Linear Security Level 3 5-25 Linear Security Level 4 5-25 Bi-directional Redundancy 5-26 Autodiscriminate Response Time 5-27 Enable/Disable UPC-E/UPC-A/UPC-E1 5-28 Enable/Disable EAN-8/EAN-13 5-29 Enable/Disable Bookland EAN 5-30 Decode UPC/EAN Supplementals 5-31 Decode UPC/EAN Supplemental Redundancy 5-32 Transmit UPC-A/UPC-E/UPC-E1 Check Digit 5-33 UPC-A Preamble 5-34 UPC-E Preamble 5-35 UPC-E1 Preamble 5-36 Convert UPC-E to UPC-A 5-37 Convert UPC-E1 to UPC-A 5-38 EAN-8 Zero Extend 5-39 Convert EAN-8 to EAN-13 Type 5-40 UPC/EAN Security Level 5-41

UPC/EAN Security Level 0 5-41 UPC/EAN Security Level 1 5-41 UPC/EAN Security Level 2 5-42 UPC/EAN Security Level 3 5-42 UPC/EAN Coupon Code 5-43 Enable/Disable Code 128 5-44 Enable/Disable UCC/EAN-128 5-45 Lengths for Code 128 5-45 Enable/Disable Code 39 5-46

Contents

Page 8 of the Symbol Technologies P470 user manual
Pagina 8 · klik om te vergroten
Pagina 8

Enable/Disable Trioptic Code 39 5-47 Set Lengths for Code 39 5-48 Code 39 Check Digit Verification 5-50 Transmit Code 39 Check Digit 5-51 Enable/Disable Code 39 Full ASCII 5-52 Convert Code 39 to Code 32 5-53 Code 32 Prefix 5-54 Enable/Disable Code 93 5-55 Set Lengths for Code 93 5-56 Enable/Disable Interleaved 2 of 5 5-58 Set Lengths for Interleaved 2 of 5 5-59 I 2 of 5 Check Digit Verification 5-61 Transmit I 2 of 5 Check Digit 5-62 Convert I 2 of 5 to EAN-13 5-63 Enable/Disable Discrete 2 of 5 5-64 Set Lengths for Discrete 2 of 5 5-65 Enable/Disable Codabar 5-67 Set Lengths for Codabar 5-68 CLSI Editing 5-70 NOTIS Editing 5-71 Enable/Disable MSI Plessey 5-72 Set Lengths for MSI Plessey 5-73 MSI Plessey Check Digits 5-75 Transmit MSI Plessey Check Digit 5-76 MSI Plessey Check Digit Algorithm 5-77 Transmit Code ID Character 5-78

Symbol Code ID Characters 5-78 Pause Duration 5-80 RS-232C Parameters 5-81

Baud Rate 5-81 Baud Rate (Continued) 5-82 Parity 5-83 Parity (Continued) 5-84 Check Receive Errors 5-85 Hardware Handshaking 5-86 Hardware Handshaking (Continued) 5-87 Hardware Handshaking (Continued) 5-88 Software Handshaking 5-88 Software Handshaking (Continued) 5-89 Software Handshaking (Continued) 5-90 Host Serial Response Time-out 5-90 RTS Line State 5-91 Stop Bit Select 5-92 ASCII Format 5-92

Page 9 of the Symbol Technologies P470 user manual — Index
Pagina 9 · klik om te vergroten
Pagina 9

Intercharacter Delay 5-93 MCL-Net Parameters 5-93

MCL-Net Baud Rate 5-93 MCL-Net Baud Rate (Continued) 5-95 MCL-Net Hex Addressing Mode 5-96 Scanner Address 5-97 MCL-Net Transmit Retries 5-97 MCL-Net Frame Timeout 5-97 Scanner Decode Beep Type 5-98 Long Range Scanning Bar Codes 5-99

Aim Mode 5-99 Aim Duration 5-100 Numeric Bar Codes 5-101 Cancel 5-103

Appendix A. Bar Code Information

UCC/EAN-128 A-1 AIM Code Identifiers A-3

Appendix B. Automatic Project Download

Appendix C. Radio Channels

Cordless Phaser RF Channels Per Country C-1

Appendix D. Messages and Error Codes

Introduction D-1 Messages D-1 Communication Errors D-2

Scanning Transmission Range D-2

Index

Feedback

Contents

Page 10 of the Symbol Technologies P470 user manual
Pagina 10 · klik om te vergroten
Pagina 10
Page 10 of the Symbol Technologies P470 user manual
Page 11 of the Symbol Technologies P470 user manual — Notational Conventions
Pagina 11 · klik om te vergroten
Pagina 11

About This Manual

Introduction

The P470/P370 RF Scanners Product Reference Guide provides general instructions for setup, operation, troubleshooting, maintenance, and programming the P370 (industrial) and P470 (retail) cordless RF scanners.

Chapter Descriptions

  • Chapter 1, The P470/P370 RF Scanner , describes the scanner and quick startup instructions.
  • Chapter 2, Set Up , explains how to set up the scanner.
  • Chapter 3, Operation , explains how to operate the scanner.
  • Chapter 4, Maintenance And Specifications , talks about the maintenance and the specifications of the scanner and the cradle.
  • Chapter 5, Parameter Menus , has all the optional parameter bar codes for personalizing your scanner.
  • Appendix A, Bar Code Information , has information about bar codes.
  • Appendix B, Automatic Project Download , describes the AutoLoad feature.
  • Appendix C, Radio Channels , lists the available RF channels per Country.
  • Appendix D, Messages and Error Codes , describes possible error codes displayed on the scanner.

Notational Conventions

The following conventions are used in this document:

Page 12 of the Symbol Technologies P470 user manual — Service Information
Pagina 12 · klik om te vergroten
Pagina 12
  • Italics are used to highlight specific items in the general text, and to identify chapters and sections in this and related documents.
  • Bullets (
  • ) indicate:
  • action items
  • lists of alternatives
  • lists of required steps that are not necessarily sequential
  • Sequential lists (e.g., those that describe step-by-step procedures) appear as numbered lists.

Related Publications

  • P470/P370 RF Scanner Quick Reference Guide , p/n 72-38493-xx
  • PL 370/470 Cradle Quick Reference Guide , p/n 72-38494-xx
  • MCL Designer for Phaser Series User’s Guide , p/n 70-37689-xx.

Service Information

If you have a problem with your equipment, contact the Symbol Support Center for your region. See page xi for contact information. Before calling, have the model number, serial number, and several of your bar code symbols at hand.

Call the Support Center from a phone near the scanning equipment so that the service person can try to talk you through your problem. If the equipment is found to be working properly and the problem is symbol readability, the Support Center will request samples of your bar codes for analysis at our plant.

If your problem cannot be solved over the phone, you may need to return your equipment for servicing. If that is necessary, you will be given specific directions.

during shipment if the approved shipping container is not used. Shipping the units improperly can possibly void the warranty. If the original shipping container was not kept, contact Symbol to have another sent to you.

Page 13 of the Symbol Technologies P470 user manual — Symbol Support Center
Pagina 13 · klik om te vergroten
Pagina 13

Symbol Support Center

For service information, warranty information or technical assistance contact or call the Symbol Support Center in:

Canada Symbol Technologies Canada, Inc. 2540 Matheson Boulevard East Mississauga, Ontario, Canada L4W 4Z2 905-629-7226

Symbol Technologies, Inc. One Symbol Plaza Holtsville, New York 11742-1300 1-800-653-5350

United Kingdom Symbol Technologies Symbol Place Winnersh Triangle, Berkshire RG41 5TP United Kingdom 0800 328 2424 (Inside UK) +44 118 945 7529 (Outside UK)

Asia/Pacific Symbol Technologies Asia, Inc. 230 Victoria Street #04-05 Bugis Junction Office Tower Singapore 188024 337-6588 (Inside Singapore) +65-337-6588 (Outside Singapore)

Australia Symbol Technologies Pty. Ltd. 432 St. Kilda Road Melbourne, Victoria 3004 1-800-672-906 (Inside Australia) +61-3-9866-6044 (Outside Australia)

Austria/Österreich Symbol Technologies Austria GmbH Prinz-Eugen Strasse 70 Suite 3 2.Haus, 5.Stock 1040 Vienna, Austria 1-505-5794 (Inside Austria) +43-1-505-5794 (Outside Austria)

Denmark/Danmark Symbol Technologies AS Gydevang 2, DK-3450 Allerod, Denmark 7020-1718 (Inside Denmark) +45-7020-1718 (Outside Denmark)

Europe/Mid-East Distributor Operations Contact your local distributor or call +44 118 945 7360

About This Guide · United States 1

Page 14 of the Symbol Technologies P470 user manual — Symbol Support Center
Pagina 14 · klik om te vergroten
Pagina 14

Finland/Suomi Oy Symbol Technologies Kaupintie 8 A 6 FIN-00440 Helsinki, Finland 9 5407 580 (Inside Finland) +358 9 5407 580 (Outside Finland)

France Symbol Technologies France Centre d'Affaire d'Antony 3 Rue de la Renaissance 92184 Antony Cedex, France 01-40-96-52-21 (Inside France) +33-1-40-96-52-50 (Outside France)

Germany/Deutchland Symbol Technologies GmbH Waldstrasse 68 D-63128 Dietzenbach, Germany 6074-49020 (Inside Germany) +49-6074-49020 (Outside Germany)

Italy/Italia Symbol Technologies Italia S.R.L. Via Cristoforo Columbo, 49 20090 Trezzano S/N Navigilo Milano, Italy 2-484441 (Inside Italy) +39-02-484441 (Outside Italy)

Latin America Sales Support 7900 Glades Road Suite 340 Boca Raton, Florida 33434 USA 1-800-347-0178 (Inside United States) +1-561-483-1275 (Outside United States)

Mexico/México Symbol Technologies Mexico Ltd. Torre Picasso Boulevard Manuel Avila Camacho No 88 Lomas de Chapultepec CP 11000 Mexico City, DF, Mexico 5-520-1835 (Inside Mexico) +52-5-520-1835 (Outside Mexico)

Norway/Norge Symbol Technologies Trollasveien 36 Postboks 72 1414 Trollasen, Norway 66810600 (Inside Norway) +47-66810600 (Outside Norway)

Symbol Technologies Kerkplein 2, 7051 CX Postbus 24 7050 AA Varsseveld, Netherlands 315-271700 (Inside Netherlands) +31-315-271700 (Outside Netherlands)

Netherlands/Nederland

Page 15 of the Symbol Technologies P470 user manual — Warranty
Pagina 15 · klik om te vergroten
Pagina 15

South Africa Symbol Technologies Africa Inc. Block B2 Rutherford Estate 1 Scott Street Waverly 2090 Johannesburg Republic of South Africa 11-4405668 (Inside South Africa) +27-11-4405668 (Outside South Africa)

Spain/España Symbol Technologies S.A. Edificioi la Piovera Azul C. Peonias, No. 2 - Sexta Planta 28042 Madrid, Spain +913244000 (Inside Spain) +34-9-1-320-39-09 (Outside Spain)

Sweden/Sverige Symbol Technologies AB Albygatan 109D Solna Sweden 84452900 (Inside Sweden) +46 84452900 (Outside Sweden)

1Customer support is available 24 hours a day, 7 days a week.

If you purchased your Symbol product from a Symbol Business Partner, contact that Business Partner for service.

For the latest version of this guide go to:http://www.symbol.com/manuals

Warranty

Symbol Technologies, Inc. (“Symbol”) manufactures its hardware products in accordance with industry-standard practices. Symbol warrants that for a period of twelve (12) months from date of shipment, products will be free from defects in materials and workmanship. This warranty is provided to the original owner only and is not transferable to any third party. It shall not apply to any product (i) which has been repaired or altered unless done or approved by Symbol, (ii) which has not been maintained in accordance with any operating or handling instructions supplied by Symbol, (iii) which has been subjected to unusual physical or electrical stress, misuse, abuse, power shortage, negligence or accident or (iv) which has been used other than in accordance with the product operating and handling instructions. Preventive maintenance is the responsibility of customer and is not covered under this warranty. Wear items and accessories having a Symbol serial number, will carry a 90-day limited warranty. Non- serialized items will carry a 30-day limited warranty.

About This Guide

Page 16 of the Symbol Technologies P470 user manual — General
Pagina 16 · klik om te vergroten
Pagina 16

Warranty Coverage and Procedure

During the warranty period, Symbol will repair or replace defective products returned to Symbol’s manufacturing plant in the US. For warranty service in North America, call the Symbol Support Center at 1-800-653-5350. International customers should contact the local Symbol office or support center. If warranty service is required, Symbol will issue a Return Material Authorization Number. Products must be shipped in the original or comparable packaging, shipping and insurance charges prepaid. Symbol will ship the repaired or replacement product freight and insurance prepaid in North America. Shipments from the US or other locations will be made F.O.B. Symbol’s manufacturing plant. Symbol will use new or refurbished parts at its discretion and will own all parts removed from repaired products. Customer will pay for the replacement product in case it does not return the replaced product to Symbol within 3 days of receipt of the replacement product. The process for return and customer’s charges will be in accordance with Symbol’s Exchange Policy in effect at the time of the exchange. Customer accepts full responsibility for its software and data including the appropriate backup thereof. Repair or replacement of a product during warranty will not extend the original warranty term. Symbol’s Customer Service organization offers an array of service plans, such as on-site, depot, or phone support, that can be implemented to meet customer’s special operational requirements and are available at a substantial discount during warranty period.

General

Except for the warranties stated above, Symbol disclaims all warranties, express or implied, on products furnished hereunder, including without limitation implied warranties of merchantability and fitness for a particular purpose. The stated express warranties are in lieu of all obligations or liabilities on part of Symbol for damages, including without limitation, special, indirect, or consequential damages arising out of or in connection with the use or performance of the product. Seller’s liability for damages to buyer or others resulting from the use of any product, shall in no way exceed the purchase price of said product, except in instances of injury to persons or property. Some states (or jurisdictions) do not allow the exclusion or limitation of incidental or consequential damages, so the preceding exclusion or limitation may not apply to you.

Page 17 of the Symbol Technologies P470 user manual — Chapter 1 The P470/P370 RF Scanner
Pagina 17 · klik om te vergroten
Pagina 17

Chapter 1 The P470/P370 RF Scanner

Introduction

The P470/P370 cordless RF scanners bring new flexibility and economy to data capture and data management in both industrial and retail operations. The scanner communicates with your host computer through radio transmission instead of through a cable. With the RF scanner, you are free to scan and transmit without a physical cable, from as far away as 100 feet (30.5 meters) even without a direct line of sight. This lets you take the scanner to where the work is, whether on the loading dock, the plant floor, the warehouse, or the POS checkout area. There are several versions available:

  • P470: cordless retail scanner
  • P370: cordless industrial scanner
  • P370 ALR: cordless industrial ALR scanner

Unless otherwise noted, the term Phaser refers to all versions of the scanner.

Page 18 of the Symbol Technologies P470 user manual — Figure 1-1. Scanner and Cradle
Pagina 18 · klik om te vergroten
Pagina 18

Rechargeable Battery

In the handle of the scanner, there is a rechargeable lithium-ion battery. This provides all power to the scanner during cordless operation. It provides 10 hours of use in a typical application. When fully depleted, the battery can be recharged to full charge in about 3-1/2 hours.

The Cradle

The PL 370/470 Cradle acts as a:

  • stand
  • 2-way RF transmitter
  • communication interface with the host
  • battery charger for the cordless scanner.

The cradle can sit on a desktop or be wall-mounted, whichever is more convenient. The cradle receives data from the scanner via the antenna on the side of the cradle. The cradle then transmits that data to the host device via an attached cable. It also acts as a holder for the scanner.

The cradle also provides power for charging the scanner’s battery (in the scanner). The cradle has a charge status indicator light that shows the status of the battery charging (Refer to Table 4-1 on page 4-3).

Charge Status Indicator Light

Figure 1-1. Scanner and Cradle

There are two versions of the cradle:

  • PL 470 Cradle: cordless retail version
  • PL 370 Cradle: cordless industrial version.

Unless otherwise noted, the term Cradle refers to both versions of the cradle.

Page 19 of the Symbol Technologies P470 user manual — Quick Startup Instructions
Pagina 19 · klik om te vergroten
Pagina 19

The P470/P370 RF Scanner

Quick Startup Instructions

Below is an index of Quick Startup Instructions to help get you up and going quickly. These instructions are also on the back cover of this guide for easy reference. The index is listed in a step by step order beginning with step 1, Setting up the System.

Mandatory steps are designated by an asterisk (*). If an item has multiple pages referenced, the most important reference is in bold.

1. Setting Up the System
  • Connecting the cradle to a host * 2-1

- RS-232 connection 2-2

- Synapse connection (keyboard wedge, USB, etc.) 2-3

  • Charging the battery * 1-2, 2-8
  • Pairing the scanner with the cradle * 2-6

- RF channel 3-8, 5-13, C-1

- Coexisting in Spectrum24 environments 2-7

2. Using the Default Applications
  • Overview of Scan and Transmit application* 3-2
  • Keypad operation 3-2, 3-3, 3-26
  • Eliminating repetitive scanning 3-4
  • Selecting the host communication protocol 3-2, 3-8, 5-8

- RS-232 baud rate 5-81

3. Programming an Advanced Data Formatting Rule Using 123Scan 3-17
  • Suffix values (appending Enter key and Tab) 3-18
4. Troubleshooting Problems
  • Troubleshooting table 3-28
  • Communication errors 3-5, D-2
  • Beeper indications and default application error codes 4-7
  • Cradle LED indications 4-3

PRG Page

Page 20 of the Symbol Technologies P470 user manual — Commonly Used P470/P370 Programming Bar Code
Pagina 20 · klik om te vergroten
Pagina 20
Symbol Technologies P470 — Commonly Used P470/P370 Programming Bar Code diagram (page 20)
Afb. 2 · Commonly Used P470/P370 Programming Bar Code

Below are commonly used programming bar codes. You can cut this page out of the guide, or make a copy of the bar codes using a high quality copying machine.

Reset Default Application (Clears previously programmed ADF rules and/or

Page 21 of the Symbol Technologies P470 user manual — Connecting to a Host
Pagina 21 · klik om te vergroten
Pagina 21

Chapter 2

Set Up

Introduction

This chapter covers the procedures for setting up the RF scanner and its accessories.

Unpacking

Remove the scanner from its packing and inspect it for damage. If the scanner was damaged in transit, call one of the telephone numbers listed in the section Symbol Support Center on page xi. KEEP THE PACKING. It is the approved shipping container and should be used if you ever need to return your equipment for servicing.

Setting Up the Cradle

The basic steps to set up the cradle are listed below and described in more detail in the following sections.

  • connecting the cradle to a host
  • mounting the cradle, if desired
  • pairing the scanner to the cradle.

Connecting to a Host

With some host types, the scanner is unable to answer host terminal polls if the appropriate host type is not selected. This may result in an error message generated by the host. To correct this situation, select the proper parameter set and initialize the host terminal. See Chapter 5, Parameter Menus for more information.

Page 22 of the Symbol Technologies P470 user manual — Figure 2-2. Power Supply Port
Pagina 22 · klik om te vergroten
Pagina 22

There are two basic host communications options available:

  • using an RS-232 cable
  • using a Synapse cable.

RS-232 Connection

1. Make sure all host devices are powered down.
2. Plug the connector at the end of the cradle’s cable into the appropriate RS-232 receiving port on the host device.
3. Plug the other end of the cable into the COM1 connector on the cradle.

COM1

Figure 2-1. Ports on the Cradle

4. Connect the power connector of the power supply into the Power port on the cradle.
5. Connect the appropriate line cord to the power supply and into an AC receptacle.
6. The indicator light on the cradle blinks, signifying successful power-up.

Figure 2-2. Power Supply Port

Power port

Page 23 of the Symbol Technologies P470 user manual — Figure 2-3. Synapse and Adapter Cable
Pagina 23 · klik om te vergroten
Pagina 23
7. Rotate the antenna to the vertical position.

Using A Synapse Cable

1. Make sure all host devices are powered down.

IMPORTANT

Before power is provided to the cradle (step 6), the following steps must be completed. The Synapse cable must be connected to the cradle (step 2) AND the flying power lead plugged in (step 4). If the cables are not connected in this sequence, the Synapse Interface Adapter will not operate properly.

2. Connect the Synapse cable to the cradle (see Figure 2-1 on page 2-2 ).
3. Connect the other end of the Synapse cable to the Synapse Interface adapter.
4. The Synapse cable has a flying power lead. Connect this lead to the receptacle in the Synapse Interface adapter, as shown in Figure 2-3 . See the Synapse guide for details.

Synapse Interface Adapter (Module)

Figure 2-3. Synapse and Adapter Cable

5. Connect the Synapse Interface adapter to the host.
6. Connect the power supply to the cradle (see Figure 2-2 ).
Show 5 more labels / short text on this page
Set Up · To Host · Synapse Cable · Flying Power Lead · To Cradle
Page 24 of the Symbol Technologies P470 user manual — Figure 2-5. Placement of Cables
Pagina 24 · klik om te vergroten
Pagina 24
7. Connect the appropriate line cord to the power supply and into an AC receptacle.
8. The indicator light on the cradle blinks, signifying successful power-up.
9. Scan the appropriate Synapse bar codes to set up the Synapse cable for your specifications.
10. Rotate the antenna to the vertical position.

Wand Emulation, OCIA, OCR, Keyboard Wedges

See the appropriate Synapse cable instructions. An adapter cable is required.

Wall Mounting

Before wall-mounting the cradle, the scanner support tab must be changed from the desk- mount position to the wall-mount position.

1. Lift the scanner support tab out of the top part of the cradle and replace it in the wall-mount position.

Desk Mount Wall Mount

Figure 2-4. Scanner Support Tab

2. Seat the cables from the bottom of the cradle in the grooves along the length of it so that the bottom of the cradle is smooth.

Figure 2-5. Placement of Cables

Cable Grooves

Page 25 of the Symbol Technologies P470 user manual — Figure 2-6. Securing Cradle to Wall
Pagina 25 · klik om te vergroten
Pagina 25
3. Fasten the two screws provided into the wall where the cradle will hang, leaving about 1/8” (0.3 cm) of the screw outside the wall for the cradle’s wall mounting sockets (A template is provided for you in the PL 370/470 Quick Reference Guide p/n 72-38494-xx).
4. Place the cradle over the screw heads and slide down until it fits into place. Slight pressure upwards should not move the cradle.

Figure 2-6. Securing Cradle to Wall

5. Position the antenna vertically (pointing toward the ceiling).
6. Place the scanner in the cradle.

Set Up

Page 26 of the Symbol Technologies P470 user manual — Pairing the Scanner with the Cradle
Pagina 26 · klik om te vergroten
Pagina 26

Pairing the Scanner with the Cradle

The scanner and cradle must be paired for communication to occur.

To pair the scanner with the cradle:

1. Scan the pairing bar code on the top of the cradle.

To pair a long range scanner (P370 ALR) to a regular P370 cradle, attach the “spare pairing bar code” label to the cradle. This 15 mil bar code, packaged with the cradle, can be scanned by the P370 ALR at a distance of approximately two feet from the cradle.

2. The scanner may briefly display the “pairing search for channel” message while the scanner searches for the base. Once the base is detected, information is exchanged (addressing, RF channels, etc.) between the scanner and the cradle.

during over-the-air pairing. To reduce the pairing time, place the scanner in the cradle.

3. After the exchange is complete, the scanner and cradle are paired.

Successful pairing is indicated by a warble beep and the base’s LED will flash. If pairing is unsuccessful, the scanner emits a Lo/Hi beep and displays the following message:

Pairing Unsuccessful Push ENTER & Try Again

The pairing of a scanner to a cradle is one-to-one. Only one scanner can be paired to a cradle at any point in time. If you pair a second scanner to an in use cradle, the cradle’s connection to the first scanner will be broken and the connection re-established with the second scanner.

To pair a scanner to a different cradle, scan its pairing bar code located on the top of the cradle.

Page 27 of the Symbol Technologies P470 user manual — Select a Channel Outside the Spectrum24 band
Pagina 27 · klik om te vergroten
Pagina 27

Optimizing RF Performance

Mounting

The RF scanner and cradle are equipped with a 2.4 GHz point-to-point radio that has an RF transmission range of 100 feet (30.5 meters) even without a direct line of sight.

In addition to being a 2-way RF transmitter, the cradle is a battery charger and should be mounted in an accessible location like on a table or desktop. For optimum RF performance, especially in difficult environments, mount the cradle on a wall as high as possible.

Coexistence in Spectrum24 Environments

If you operate your scanner or cradle in close proximity to a Spectrum24 device, maintain a buffer of 3 feet or greater between the transmitters. A Spectrum24 device includes but is not limited to a terminal with a Spectrum24 radio, PC with a Spectrum24 card, or a Spectrum24 Access Point. If a scanner or cradle is less than 3 ft. from a 2.4 GHz Spectrum24 transmitter (antenna), especially an Access Point, your communication performance may degrade.

Select a Channel Outside the Spectrum24 band

In the unlikely event that Spectrum24 radio traffic causes interference between the scanner and the cradle, you can change the scanner’s RF channel to one that minimizes or eliminates the interference.

Phaser cordless scanners have three channels that are not within the Spectrum24 band, 81, 82, and 83*. As a rule of thumb, the Cordless systems operated closest to Spectrum24 devices should use these channels. For instructions on how to change the scanner’s RF channel, see System Setup Options on page 3-8.

In applications with low scanning/data transmission duty cycles, you may assign the same channel to more than one cordless scanner.

After channels 81, 82 and 83, the next best channels to use are 60 through 80; the higher the channel the better. See Appendix C, Radio Channels for a list of available radio channels per country.

* Not available in some countries.

Set Up

Page 28 of the Symbol Technologies P470 user manual — Charging the Battery
Pagina 28 · klik om te vergroten
Pagina 28

Phaser-to-Phaser Co-Existence

Up to three P470/370 scanners within listening range (100 feet) of each other can be operated on the same channel with little or no interference, assuming average scanning rates.

For higher than average scanning rates, P470/370 scanners within listening range (100 feet) of each other should be operated on different channels, set apart by at least one channel (for example, 2, 4, 6, etc.). Cordless Phaser scanners support up to 82 communication channels. Not all channels are available in all countries. Refer to Appendix C, Radio Channels for more information.

Increase the number of RF Retries

If the scanner’s transmission is not received by the cradle or the base’s acknowledgment response is not received by the scanner (see Communication Errors on page 3-5), the scanner retransmits the lost or corrupted data. The scanner attempts 4 RF Retries (default) but can be programmed to attempt up to 8.

Depending on your particular RF environment, additional retries may cause your scanner transaction time to increase in the presence of heavy Spectrum24 traffic.

Charging the Battery

Before its first use, the scanner’s battery must be charged. It can be charged:

  • Using the cradle
  • Using the UBC 2000.
Page 29 of the Symbol Technologies P470 user manual — Battery Charge
Pagina 29 · klik om te vergroten
Pagina 29

Using the Cradle

1. Set up the cradle as described in Setting Up the Cradle on page 2-1. .

Figure 2-7. Placing the Scanner into the Cradle

2. Insert the scanner into the cradle so that the nose of the scanner and tip of the handle seat into the receptacles. The scanner displays “UNIT CRADLED” when properly inserted in the cradle.
3. The battery charges automatically. A full charge of a depleted battery takes approximately 3-1/2 hours.

The cradle recharges batteries in the scanner only when the scanner is in the cradle. A scanner with a depleted battery starts charging immediately upon insertion into the cradle, whereas a scanner with a partially charged battery begins charging after approximately 15 minutes. Note that the scanner can be removed from the cradle at any time.

Using the UBC 2000

The battery can be charged using the Universal Battery Charger UBC 2000. The UBC adapter for the P470/P370 scanner battery is required. Refer to the UBC 2000 guide for information on recharging the battery using the UBC 2000.

Battery Charge

When the battery’s charge is almost depleted, the scanner emits 4 high tone beeps, when the trigger is pulled, indicating that it must be recharged.

Set Up

Page 30 of the Symbol Technologies P470 user manual — Using the Cradle
Pagina 30 · klik om te vergroten
Pagina 30
Page 30 of the Symbol Technologies P470 user manual — Using the Cradle
Page 31 of the Symbol Technologies P470 user manual — Default Application
Pagina 31 · klik om te vergroten
Pagina 31

Chapter 3 Operation

Introduction

This chapter covers how to use the cordless Phaser scanner.

Default Application

The cordless scanner is shipped from the factory with a default scan and transmit application.

This application allows users to scan and view data, enter quantities, and manually enter alphanumeric data.

When the unit is powered up, it displays the system start-up banner. Alternatively, the scanner can be reset manually by pressing the key, then the key. When the scanner is powered up or reset, the system banner appears as follows:

Symbol Technologies · Phaser RF

Page 32 of the Symbol Technologies P470 user manual — Numeric Data Entry
Pagina 32 · klik om te vergroten
Pagina 32

Initial Powerup

After a few seconds, the System Banner is replaced by the system initialization screen.

Symbol Technologies Initializing...

After initialization, the scanner enters the Scan & Transmit application. The default communication protocol is RS232/Synapse.

If a Synapse cable is attached, the scanner automatically overrides the default settings.

Scan and Transmit Application

The scan and transmit application allows you to:

  • Display and simultaneously transmit data to a host
  • Eliminate repetitive scanning with a quantity entry feature
  • Manually enter alphanumeric data if no bar code is present.

If the scanner powers down, pull the trigger or press the key to wake it up.

The scan and transmit screen appears as follows:

SKU:

In this mode, scanned bar codes are automatically transmitted to the cradle and then the host in real time.

Numeric Data Entry

The default application also allows you to manually enter data if no bar code is present.

By default, this feature is enabled. To disable alphanumeric data entry via the keypad, go to the symbologies tab inside 123Scan and remove the “X” from the check box next to “Keypad”. (This does not disable the quantity entry feature discussed in Eliminating Repetitive Scanning on page 3-4.)

Page 33 of the Symbol Technologies P470 user manual — Alpha Data Entry
Pagina 33 · klik om te vergroten
Pagina 33

With keypad entry enabled (default setting out of the box), press the key after keying in data. During data entry, the key corrects keying errors digit by digit, and the then combination clears the screen so you can start over. If your entry exceeds 34 characters, the characters will scroll off the visible portion of the screen, but are retained for storage.

Alpha Data Entry

To enter alpha characters via the keypad (with keypad enabled, page 3-26), press the key once to put the scanner in Alpha Mode.

Numeric buttons 1 through 9 are associated with the alpha characters. For example, the letters A, B and C are located on numeric button 7. Press the button with the letter you desire - once for the letter A, twice for the letter B, or three times for the letter C. You can continue entering alpha characters or switch to numerics. Press to send the data.

To return to numeric entry mode after entering alpha characters, press the key again. For example, to manually enter 17ABF5, do the following steps:

1 Press numeric button 1.

7 Press numeric button 7.

A Press button once, then numeric button 7 once. Wait for one second (you will hear a low pitched beep).

B Press numeric button 7 twice.

F Press numeric button 8 three times.

5 Press button once, then numeric button 5 once, then .

For more information, refer to Keypad Operation on page 3-26.

Operation · Data Action

Page 34 of the Symbol Technologies P470 user manual — Eliminating Repetitive Scanning
Pagina 34 · klik om te vergroten
Pagina 34

Eliminating Repetitive Scanning

To eliminate repetitive scanning of identical items, you can enter a quantity prior to scanning a bar code. This quantity entry feature can also be used when manually entering bar code data.

To enter a quantity, press the * key. The following screen with a default value of “1” will appear:

Quantity1 ^ _____________

To enter the value you desire, key in the quantity followed by the key. Next, the bar code data entry screen reappears. Scan the item’s bar code. The scanner sends the bar code data to the host the keyed-in amount of times. For instance, if you type in a quantity of 6 then scan a bar code, the scanner sends that bar code data to the host six times as if the bar code had been scanned six times.

If you have accidentally entered this screen, it will automatically be exited after 5 seconds or by pressing the key without entering a quantity.

Page 35 of the Symbol Technologies P470 user manual — RF Communication Errors
Pagina 35 · klik om te vergroten
Pagina 35

Communication Errors

A communication error occurs when the scanner, cradle or host fails to properly communicate. When a communication error occurs using the default application, the scanner emits 4 beeps (LO HI LO HI) and displays a "Failed Communication" error message, like the one shown below. The three-digit error code on the scanner screen indicates what type of communication problem occurred. Error code 015 generally indicates the scanner is out of RF range, not properly paired to the base, or the base may have lost power. For a detailed list of all the error codes see Appendix D, Messages and Error Codes and Beeper Indications / Default Application Error Codes on page 4-7.

Failed Communication Error 015 Push ENTER

To return to the application, press .

Three types of communication errors can occur:

1. The RF transmitted data was NOT received by the cradle.
2. The cradle received the RF transmitted data, but the scanner did NOT receive a cradle's acknowledgment.
3. The host and cradle are not communicating properly.

RF Communication Errors

1. If the RF transmitted data was NOT received by the cradle, move the scanner closer to the cradle to reestablish communication, then re-scan the bar code. If the communication has been reestablished, the scanner will sound a good decode beep and no error beeps. Resume normal scanning.

2. If the cradle received the RF transmitted data, but the scanner did NOT receive a cradle's acknowledgment, move the scanner closer to the cradle to reestablish communication, then re-scan the bar code. If the communication has been reestablished, the scanner will sound a good decode beep and no error beeps. In this scenario data may have been transmitted to the host. If the cradle had previously sent data to the host, it will NOT pass this re-scanned data to the host. Resume normal scanning.

For additional information see Optimizing RF Performance on page 2-7.

Operation

Page 36 of the Symbol Technologies P470 user manual — Host / Cradle Communication Errors
Pagina 36 · klik om te vergroten
Pagina 36

Host / Cradle Communication Errors

3. If the host and cradle are not communicating properly, insure the cabling is properly connected, baud rate is properly set, and correct COM port has been selected.
Page 37 of the Symbol Technologies P470 user manual — System Menu
Pagina 37 · klik om te vergroten
Pagina 37

System Menu

The system menu allows the user to set up the operation of the scanner, such as loading a new application, set the scanner’s RF channel, setting the scanner ID, etc.

Enter the System Menu by scanning the bar code below or by entering a keypad sequence.

Commonly used System Menu programming bar codes have been consolidated on page 1-4.

Enter System Menu Bar Code

To access the System Menu using the keypad sequence, press the , then the key, followed by the key, then the key.

When you enter the system menu, the following screen appears:

Phaser Setup 0. System Setup

Below is the list of available options. Press the Up and Down arrow keys to scroll through them. Press to select a menu option. You can also select a menu option directly by typing the associated menu option number and then pressing .

0. System Setup 1. App. Control 2. Parameter Control 3. System Status 4. Version 9. Return to App.

The system menu options are described below.

Operation

Page 38 of the Symbol Technologies P470 user manual — System Setup Options
Pagina 38 · klik om te vergroten
Pagina 38

System Setup Options

System Setup allows you to configure the scanner’s basic settings such as setting an RF channel.

0. Set Com Protocol -RS232/Synapse -MCL NET -Back to Com Protocol

Sets the communication protocol used by the default application. The options are MCL-Net or RS232/Synapse. If RS232/Synapse is selected, the scanner automatically identifies whether an RS- 232 or Synapse interface is required. To cancel the change, press the then keys, and to accept the change, press the key.

1. Set RF Channel Allows the user to set/change the RF channel used for communication between the scanner and cradle.

The cordless Phaser scanner operates on a single, programmable channel (frequency) between 2.402 GHz (channel 02) and 2.483 GHz (channel 83).

A maximum of 81 channels are available. Not all channels are available in all countries. If a channel is not legal to use in your country, an error beep will be heard instead of a successful warble. For a list of Channel Availability by Country, see Appendix C, Radio Channels.

Channel54 New Channel: _ _

To cancel the change, press the then keys, and to accept the change, press the key.

2. Set Contrast Sets the display contrast. The scanner displays the current contrast setting. Use the up and down arrow keys to change the contrast. The default contrast is 7, and the range is from 0 to 15, with 0 being the lightest and 15 being the darkest. To cancel the change, press the then keys, and to accept the change, press the key.
3. Set Scanner ID Sets the scanner ID. The scanner displays its current ID, and the user may key in a new value between 1 and 254. The default is 001. To cancel the change, press the then keys, and to accept the change, press the key.
9. Back to Main Returns the user to the system menu.

Option Description

Page 39 of the Symbol Technologies P470 user manual — Load New App. <ENTER>=YES <BK>=NO
Pagina 39 · klik om te vergroten
Pagina 39

App. Control

App. Control allows you to control your application, specifically, load new applications on your scanner, reset your default applications, etc.

You can load a new application or system code by either scanning the appropriate bar code or entering the appropriate keypad value as indicated on the display.

0. Load App Puts the scanner into a mode to receive MCL-Designer application downloads and MCL-Link commands from the host. To enter this mode using the key pad, select this option on the system menu. The following screen displays:

Load New App. <ENTER>=YES <BK>=NO

OR To enter this mode from an application without entering the system menu or entering key strokes, scan the bar code below.

Load New MCL-Designer Application

Scanner ready, on PC start download

When this screen displays, the scanner is ready to accept the download. On the PC Utility, initiate the download. After downloading is complete, the system menu is exited and the application initiated. To exit this mode and prevent the download of a new application, press the then keys.

Operation · Option Description

Page 40 of the Symbol Technologies P470 user manual — Reset Default App? <ENTER>=YES <BK>=NO
Pagina 40 · klik om te vergroten
Pagina 40
1. Set Default App Reinstalls the default application and returns all parameters to their factory settings (values listed in Table 5-1 ). The default application overwrites any MCL-Designer application and/or ADF rules. This option may be used to restore functionality to a scanner which has been loaded with a defective application. To enter this mode using the key pad, select this option on the system menu. Prior to resetting the default application, the user is prompted to confirm this operation:

Reset Default App? <ENTER>=YES <BK>=NO

Press the key to confirm the choice (Yes) or the key to cancel the choice (No). If you entered “Set Default App” from the System Menu, upon resetting the default application, you will return to the System Menu.

OR To enter this mode from an application without entering the system menu or entering key strokes, scan the bar code below.

Reset Default Application (Clears previously programmed ADF rules and/or

If you entered the “Set Default App” mode using the bar code above, the default application will automatically be reset, the System Menu exited, and the application re-initiated.

Option Description · MCL-Designer applications)

Page 41 of the Symbol Technologies P470 user manual — System Menu
Pagina 41 · klik om te vergroten
Pagina 41
2. Enable AutoLoad AutoLoad App.

Enables the automatic application download feature in the default application. This allows the user to remove the scanner from the box, pair it with the cradle, place the scanner in the cradle and automatically download a new application to the scanner.

In order for this feature to operate properly, the cradle must be connected to a host running MCL-Link, and the user’s host must be configured properly with specific files in specific locations (See Appendix A). If the user does not set up the host in the required manner, the scanner reverts to normal charging mode. This feature is enabled by default, but may be disabled by use of this System Menu item.

Selecting Enable will enable this feature; Disable will disable this feature. To exit without changing this setting, press then .

Operation · Option Description · -Enable -Disable

Page 42 of the Symbol Technologies P470 user manual — Load New System Code <ENTER>=YES <BK>=NO
Pagina 42 · klik om te vergroten
Pagina 42
3. System Code Updates the scanner operating system (Firmware). To enter this mode using the key pad, select this option on the system menu.

Load New System Code <ENTER>=YES <BK>=NO

Press the key to confirm the choice (Yes) or the key to cancel the choice (No).

OR To enter this mode from an application without entering the system menu or entering key strokes, scan the bar code below.

Place unit in cradle on PC start download

Place the scanner in the cradle before initiating the download from the PC Utility. After the download is complete, the system menu is exited and the application initiates. To exit this mode and prevent the download of new firmware, press and hold the key for 30 seconds. In addition, power to the cradle must be cycled (powered off then on) before it will communicate with the scanner again.

Option Description · System Code

Page 43 of the Symbol Technologies P470 user manual — Load New Base Code <ENTER>=YES <BK>=NO
Pagina 43 · klik om te vergroten
Pagina 43
4. Base Station Code Updates the cradle’s operating system (Firmware). To enter this mode using the key pad, select this option on the system menu.

Load New Base Code <ENTER>=YES <BK>=NO

Press the key to confirm the choice (Yes) or the key to cancel the choice (No).

OR To enter this mode from an application without entering the system menu or entering key strokes, scan the bar code below.

Base Station ready, on PC start download

To start the download to the cradle, press the start button on the PC Utility. Note: You will automatically exit this message after 15 seconds and return to the application, even if the PC download is NOT initiated.

To exit this mode and prevent the download of new firmware or if the PC download is not initiated, the power to the cradle must be cycled (powered off then on) before it will communicate with the scanner again. No action is required on the scanner side.

9. Back to Main Returns the user to the system menu.

Operation · Option Description · Base Station Code

Page 44 of the Symbol Technologies P470 user manual — System Status
Pagina 44 · klik om te vergroten
Pagina 44

Parameter Control

Parameter Control allows you to control the scanner parameters such as Scan Parameters and Set Default Params.

0. Scan Parameters This feature only works when used with an application generated with MCL-Designer and allows you to program your scanner by scanning the bar codes in Chapter 5, Parameter Menus . Parameters already set in your MCL-Designer generated application can not be overridden by scanning bar codes. When you see the following screen, you can begin scanning parameter bar codes:

Scan Parameters to quit

After scanning the desired bar codes, press then to exit this mode.

1. Set Default Param Restores the default parameters in the scanner. The default parameters overwrite any scanned parameters. Prior to resetting the default parameters, you are prompted to confirm your choice.
9. Back to Main Returns the user to the system menu.

System Status

System Status allows you to perform system checks such as Battery Check.

0. Battery Check Checks the battery charge level. Good indicates the battery does not require recharging. Low/Recharge indicates the scanner requires a recharge. When the battery is close to complete discharge, the following message displays:
9. Back to Main Returns the user to the system menu.

Option Description · Option Description · Recharge Battery

Page 45 of the Symbol Technologies P470 user manual — Version
Pagina 45 · klik om te vergroten
Pagina 45

Version

0. Scanner Version This option displays the version of firmware (operating system) run by the scanner. For example, the firmware version shown on the display below is NBRVRAAG, also called Revision “G” (which is the last letter of the firmware’s full name NBRVRAAG).

To enter this mode using the keypad, select this option on the System Menu. The following screen displays.

ScannerNBRVRAAG MCL: 4.1

If you entered “Scanner Version” from the System Menu, after 15 seconds or by pressing , you will return to the System Menu.

OR To enter this mode from an application outside of the System Menu, scan the bar code below.

If you entered “Scanner Version” using the bar code above, after 15 seconds or by pressing , you will automatically exit the System Menu and re-enter the application.

Operation · Scanner Firmware Version

Page 46 of the Symbol Technologies P470 user manual — Return to App
Pagina 46 · klik om te vergroten
Pagina 46
1. Cradle Version This option displays the version of firmware (operating system) run by the cordless scanner’s cradle. For example, the firmware version shown on the display below is NBRVCAAF, also called Revision “F” (which is the last letter of the firmware’s full name NBRVCAAF).

To enter this mode using the keypad, select this option on the System Menu. The following screen displays.

CradleNBRVCAAF

If you entered “Cradle Version” from the System Menu, after 15 seconds or by pressing , you will return to the System Menu.

OR To enter this mode from an application outside of the System Menu, scan the bar code below.

If you entered “Cradle Version” using the bar code above, after 15 seconds or by pressing , you will automatically exit the System Menu and re-enter the application.

9. Back to Main Returns the user to the system menu.

Return to App

Return to App. Return to App exits the system menu and returns to the application. To do this, press then .

Cradle Firmware Version

Page 47 of the Symbol Technologies P470 user manual — 123Scan
Pagina 47 · klik om te vergroten
Pagina 47

123Scan

123Scan is an intuitive Windows based utility that allows you to customize your scanner setup and generate Advanced Data Formatting (ADF) rules. An Advanced Data Formatting rule gives you the ability to modify the bar code data before sending it to the host such as appending a carriage return, or some other prefix/suffix value, to the bar code data. This enhances capability between bar code data and your host software, allowing you to program the scanner rather than modifying your host application. The cordless scanner can be programmed via a cordless (RF) download or by scanning 123Scan generated programming bar codes. Scanner programming is saved in a setup file which can be distributed electronically (Web site, floppy disk, E-mail, or fax).

A copy of 123Scan is on the CD included with your scanner. It is also available on the Symbol Web site http://www.symbol.com. Use the web site’s search tool to find “123Scan” and select the P470/370 product line.

with the default application only and will not work with applications created with MCL-Designer.

To download a 123Scan generated ADF rule, scan the bar code below, then initiate the download on the PC utility.

To remove previously programmed ADF rules from the scanner, scan the bar code below.

Reset Default Application (Clears previously programmed ADF rules)

Operation · Load 123Scan File

Page 48 of the Symbol Technologies P470 user manual — Suffix Values
Pagina 48 · klik om te vergroten
Pagina 48
Symbol Technologies P470 — Suffix Values diagram (page 48)
Afb. 3 · Suffix Values

123Scan generated programming bar codes for two commonly used suffixes (Enter and Tab) have been included in this Product Reference Guide.

To append an Enter key* to the transmitted bar code data, scan all nine (9) ADF rule bar codes and then the Reset Scanner bar code, in that order.

Page 49 of the Symbol Technologies P470 user manual — Suffix Values
Pagina 49 · klik om te vergroten
Pagina 49
Symbol Technologies P470 — Suffix Values diagram (page 49)
Afb. 4 · Suffix Values

Operation

Page 50 of the Symbol Technologies P470 user manual — Suffix Values
Pagina 50 · klik om te vergroten
Pagina 50

To append a Tab* to the transmitted bar code data, scan all nine (9) ADF rule bar codes and then the Reset Scanner bar code, in that order.

Symbol Technologies P470 — Suffix Values diagram (page 50)
Afb. 5 · Suffix Values
Page 51 of the Symbol Technologies P470 user manual — Suffix Values
Pagina 51 · klik om te vergroten
Pagina 51
Symbol Technologies P470 — Suffix Values diagram (page 51)
Afb. 6 · Suffix Values

Operation

Page 52 of the Symbol Technologies P470 user manual — Figure 3-1. Scanning a Bar Code
Pagina 52 · klik om te vergroten
Pagina 52

Scanning

The scanner ships with the default application and default parameters and is ready-to-use right out of the box. If this is not what you need for your application, refer to the MCL Designer Manual for programming instructions and Chapter 5, Parameter Menus for scanning and communications parameters. If you need assistance, contact your local supplier or Symbol Support Center.

1. Make sure the bar code is in the correct scanning range. Aim and press the trigger. The scanner has read the symbol when:
  • You hear a beep.
  • The LED above the screen turns green.
  • The red laser turns off.

Figure 3-1. Scanning a Bar Code

Scan the Entire Symbol

  • Your scan beam must cross every bar and space on the symbol.
  • The larger the symbol, the farther away you should hold the scanner.
  • Hold the scanner closer for symbols with bars that are close together.
  • A short, high tone beep indicates a good decode.
Page 53 of the Symbol Technologies P470 user manual — Figure 3-2. Maximum Tilt Angles and Dead Zone
Pagina 53 · klik om te vergroten
Pagina 53

Right Wrong

Symbol Technologies P470 — Right Wrong diagram (page 53)
Afb. 7 · Right Wrong

Hold at an Angle

Do not hold the scanner directly over the bar code. Laser light reflecting directly back into the scanner from the bar code is known as specular reflection. This strong light can “blind” the scanner and make decoding difficult. The area where specular reflection occurs is known as a “dead zone.”

You can tilt the scanner up to 65° forward or back and still achieve a successful decode. Simple practice quickly shows what tolerances to work within.

Shaded area represents dead zone ( 2 ) +_

Scan Beam Scan Beam

Bar Code Bar Code Bar Code

Figure 3-2. Maximum Tilt Angles and Dead Zone

Operation

Page 54 of the Symbol Technologies P470 user manual — Figure 3-3. P470/P370 1D Scanner - Decode Zone
Pagina 54 · klik om te vergroten
Pagina 54

Decode Zone

15.6 in. 39.6 cm

10 in. 25.4 cm

5 in. 12.7 cm

0 in. 0 cm

5 in. 12.7 cm

10 in. 25.4 cm

7.5 mil

15.6 in. 39.6 cm

100% UPC

0 in. 0 cm 5 in. 12.7 cm 10 in. 25.4 cm 15 in. 38.1 cm 20 in. 50.8 cm 25 in. 63.5 cm 30 in. 76.2 cm 35 in. 88.9 cm 40 in. 101.6 cm 45 in. 114.3 cm

Distance From Front Of Scanner

Figure 3-3. P470/P370 1D Scanner - Decode Zone

Show 9 more labels / short text on this page
Width · Of · Field · 5 mil · 10 mil · 15 mil · 20 mil · 40 mil · 55 mil
Page 55 of the Symbol Technologies P470 user manual — Figure 3-4. P370 ALR Scanner - Decode Zone
Pagina 55 · klik om te vergroten
Pagina 55

20.0 in. 50.4 cm

15.0 in. 38.1 cm

10 in. 25.4 cm

5 in. 12.7 cm

0 in. 0 cm

5 in. 12.7 cm

100% UPC

10 in. 25.4 cm

15.0 in. 38.1 cm

20.0 in. 50.8 cm

0 in. 0 cm 35 in. 88.9 cm 70 in. 177.8 cm 105 in. 266.7 cm 140 in. 355.6 cm 175 in. 444.5 cm 210 in. 533.4 cm 245 in. 622.3 cm 280 in. 711.2 cm 315 in. 800.1 cm

350 in. 889.0 cm 385 in. 977.9 cm

Distance From Front Of Scanner

Figure 3-4. P370 ALR Scanner - Decode Zone

Show 9 more labels / short text on this page
Operation · Width · Of · Field · 15 Mil · 40 Mil · 55 Mil · 70 Mil Reflective · 100 Mil Reflective
Page 56 of the Symbol Technologies P470 user manual — Keypad Operation
Pagina 56 · klik om te vergroten
Pagina 56

Keypad Operation

Instead of scanning a bar code, you can enter the bar code data using the keypad on the top of the scanner. By default, this feature is enabled. To disable alphanumeric data entry via the keypad, go to the symbologies tab inside 123Scan and remove the “X” from the check box next to “Keypad”. (This does not disable the quantity entry feature discussed in Eliminating Repetitive Scanning on page 3-4.)

For additional information on 123Scan, see 123Scan on page 3-17.

To enter numeric data, type the numeric value desired and press . A beep lets you know that the entry was accepted. See Figure 3-5 on page 3-27.

To enter alpha characters, press the key once to put the scanner in Alpha Mode.

Numeric buttons 1 through 9 are associated with the alpha characters. For example, the letters A, B and C are located on numeric button 7. Press the button with the letter you desire - once for the letter A, twice for the letter B, or three times for the letter C. You can continue entering alpha characters or switch to numerics. Press to save or send the data.

To return to numeric entry mode after entering alpha characters, press the key again. For example, to manually enter 17ABF5, do the following steps:

1 Press numeric button 1.

7 Press numeric button 7.

A Press button once, then numeric button 7 once. Wait for one second (you will hear a low pitched beep).

B Press numeric button 7 twice.

F Press numeric button 8 three times.

5 Press button once, then numeric button 5 once, then .

Every time you press the button with the letter you desire, you hear a low-pitched beep to let you know that the entry was registered. Although the entry is registered, it has not been

Data Action

Page 57 of the Symbol Technologies P470 user manual — Figure 3-5. Scanner Keypad
Pagina 57 · klik om te vergroten
Pagina 57

transferred to the host yet. A high-pitched beep lets you know that the entry has been transferred to the host.

To return to numeric mode, press the Mode key again. Pressing the Enter key saves the data.

To put a decimal point (.) into numeric data, type in the numbers before the decimal point, then press the mode key, press the decimal, and press the mode key again. Now resume typing in the values to the right of the decimal.

To enter a dash (-), press the mode key once, then the zero (0) key twice.

To enter a blank space ( ), press the mode key once, then the zero (0) key three times.

The Function key in combination with a numeric key can be programmed to launch an operation. For more information on how to program these keys for additional tasks and operations, refer to the MCL Designer User’s Guide p/n 70-37689-XX.

Figure 3-5. Scanner Keypad

Operation

Page 58 of the Symbol Technologies P470 user manual — Table 3-1. Troubleshooting Table
Pagina 58 · klik om te vergroten
Pagina 58

Troubleshooting

Refer to Appendix D, Messages and Error Codes for additional troubleshooting information.

Table 3-1. Troubleshooting Table

General problem solving • Check that the power supply is attached to the cradle.

  • Check for loose cable connections at the cradle, AC power supply, or host device.
  • Make sure the scanner and cradle have been successfully paired.
  • Check the scanner’s battery charge level. See Battery Check on page 3-14 .
  • Make sure the device is programmed to read the type of bar code you want to scan.
  • Check the symbol to make sure it is not defaced.
  • Try scanning another similar symbol of the same code type.
  • Be sure you’re within the proper scanning decode range.
  • Make sure you are within the proper RF transmission range.
  • Cycle power (power off then on) to the base.
  • Reboot (reset) the scanner (hold down the ENTER key for about 30 seconds) and try scanning again.

The scanner emits error beeps after decoding a bar code.

  • Check that the cradle is powered up and that it’s cable connections are secure. See Setting Up the Cradle on page 2-1.
  • Check that the scanner is successfully paired with the cradle. See Pairing the Scanner with the Cradle on page 26 .
  • Check that you are within transmitting range. See Communication Errors on page 3-5 and Appendix D, Messages and Error Codes .

Problem Solution

Page 59 of the Symbol Technologies P470 user manual — Table 3-1. Troubleshooting Table (Continued)
Pagina 59 · klik om te vergroten
Pagina 59

Table 3-1. Troubleshooting Table (Continued)

  • For MCL-Designer generated applications, put the scanner into “Scan Parameter” mode in the system menu (see Scan Parameters on page 3-14).

The scanner does not scan the programming bar codes in this PRG.

  • For the default application running on a previous version of firmware (Revision F or lower, such as E), put the scanner into “Scan Parameter” mode in the system menu (see Scan Parameters on page 3-14). For instructions on how to check the scanner’s firmware version, see Version on page 3-15.

The PC cannot download an application to the scanner.

  • Check to make sure you are using an RS-232 cable. The application can not be downloaded to a scanner using a Synapse cable.
  • Make sure the scanner and cradle are successfully paired.
  • Check to make sure the power supply is connected to the base.
  • If the problem continues, cycle power to the base (powered off then on).

Received an 015 communication error while using a Synapse cable.

  • The cables connected to the cradle were not connected in the correct sequence. Before power is applied to the cradle, the Synapse cable must be connected to the cradle AND the flying power lead plugged in. See Using A Synapse Cable on page 2-3 for more information
  • To pair a long range P370 ALR scanner with a PL370 cradle, attach the spare pairing bar code label to the cradle and scan the bar code. For additional information, see Pairing the Scanner with the Cradle on page 2-6 .

The P370 ALR scanner will not pair with a PL370 cradle.

Operation · Problem Solution

Page 60 of the Symbol Technologies P470 user manual — Table 3-1. Troubleshooting Table (Continued)
Pagina 60 · klik om te vergroten
Pagina 60

Table 3-1. Troubleshooting Table (Continued)

  • Software download to the scanner while the scanner is running the default application.

The Scanner will not load my ADF rule.

  • Check that the scanner is successfully paired with the cradle (see page 2-6 ).
  • Check that the cradle and PC are connected using an RS-232 cable.
  • Software download or scanning a bar code sheet while the scanner is running an MCL-Designer generated application
  • Erase the MCL-Designer application from the scanner’s memory by scanning the “Reset Default Application” bar code on page 3-10 .
  • The default application is now reinstalled and an ADF rule can be loaded.

contact your distributor or call the Symbol Support Center. See Symbol Support Center on page page xi for the telephone number.

Problem Solution

Page 61 of the Symbol Technologies P470 user manual — Changing the Battery
Pagina 61 · klik om te vergroten
Pagina 61

Chapter 4 Maintenance And Specifications

Introduction

This chapter explains how to maintain your scanner and the specifications for it.

Maintenance

  • Do not allow any abrasive material to touch the scanner window.
  • Remove any dirt particles with a damp cloth.
  • Wipe the scanner window using a damp cloth, and if necessary, a non-ammonia based detergent.
  • Do not spray water or other cleaning liquids directly into the scanner window.
  • If the contacts between the scanner and cradle become dirty, clean them with either a pencil eraser or a cotton swab dampened with alcohol.
  • If a significant decrease in battery life is noticed and does not correspond to increased usage, consider replacing the battery.

Changing the Battery

Once a battery is fully charged, it will generally last up to 10 hours without being returned to the cradle. By returning it to the cradle during the day, you extend this time.

Page 62 of the Symbol Technologies P470 user manual — Removing the Battery
Pagina 62 · klik om te vergroten
Pagina 62
Symbol Technologies P470 — Removing the Battery diagram (page 62)
Afb. 8 · Removing the Battery
1. Slide the release latch down using center indent and remove the cover.
2. Slide the battery toward the bottom of the scanner and then pull the bottom of the battery back and out of the scanner.
1. Place the top portion of the battery (curved side up, contacts toward top) into the scanner and then slide it up the handle.
3. Slide the release latch up to secure the cover in place.
Page 63 of the Symbol Technologies P470 user manual — Table 4-1. Cradle LED Indications
Pagina 63 · klik om te vergroten
Pagina 63

Charge Status LED Indications

The LED indicator on the cradle uses flashing patterns to display the charger status, as shown in the table below.

Table 4-1. Cradle LED Indications

Off The scanner is not in the cradle or has not been properly inserted into the cradle.

Blinking Slowly The scanner is properly seated in the cradle and charging will begin shortly.

Blinking Rapidly The battery is actively charging.

On Battery charging is complete.

Maintenance And Specifications · LED Status

Page 64 of the Symbol Technologies P470 user manual — Table 4-2. Technical Specification s
Pagina 64 · klik om te vergroten
Pagina 64

Technical Specifications

Table 4-2. Technical Specification s

Decode Capability The RF scanner can be programmed to decode the following code types: UPC/EAN, Bookland EAN, Code 11, Code 39, Code 39 Full ASCII, Trioptic Code 39, Code 93, Codabar, Interleaved 2 of 5, Code 128, EAN 128, Discrete 2 of 5, MSI Plessey, and Coupon Code. The RF scanner can auto-discriminate between all of the above code types except for Code 39 and Code 39 Full ASCII.

Scanner Beeper Operation User-selectable: Enabled, Disabled.

Scan Repetition Rate 35 (± 5) scans/sec (bidirectional)

Roll (Skew) Tolerance ± 30° from normal

Pitch ± 65° from normal

Yaw ± 60° from normal

Decode Depth of Field See Decode Zone on page 3-24.

Print Contrast Minimum 20% absolute dark/light differential, measured at the wavelength of the laser diode.

Artificial Lighting 450 ft. candles 4844 lux

Sunlight 10,000 ft. candles 107,640 lux

P370 (Industrial) P470 (Retail)

-4° to 122°F -20° to 50°C 32° to 104°F 0° to 40°C

Storage Temperature -40° to 140°F -40° to 60°C

Sealing P370: All components sealed to IP 54 specification against wind blown dust and rain.

Humidity 5% to 95% (non-condensing)

P370 (Industrial) P470 (Retail)

P3706-ft. (1.8 m) P470: 5-ft. (1.5 m) Drops to concrete over entire temperature range
Show 4 more labels / short text on this page
Item Description · Ambient Light Immunity · Operating Temperature · Durability (Scanner)
Page 65 of the Symbol Technologies P470 user manual — Table 4-2. Technical Specifications (Continued)
Pagina 65 · klik om te vergroten
Pagina 65

Table 4-2. Technical Specifications (Continued)

Height 7.0 in. (17.8 cm)

Width 9.2 in. (13.5 cm)

Depth 3.5 in. (9.8 cm)

Laser Classifications CDRH Class II, IEC Class 1, IEC Class 2

Maintenance And Specifications · Item Description · Dimensions

Page 66 of the Symbol Technologies P470 user manual — 9 CTS - IN
Pagina 66 · klik om te vergroten
Pagina 66

Cradle Pin-outs

The following table shows the pin-outs for COM1 on the cradle.

Table 4-3. Pin-outs

6 RXD IN

7 TXD OUT

8 DTR (Tied HI)

9 CTS - IN

10 RTS - OUT

Show 7 more labels / short text on this page
Pin Cradle · Pin 1 · 1 Reserved · 2 VCC (Out) · 3 Ground · 4 Synapse Data · 5 Synapse Clock
Page 67 of the Symbol Technologies P470 user manual — N/A
Pagina 67 · klik om te vergroten
Pagina 67

Beeper Indications / Default Application Error Codes

Table 4-4 list beep sequence and their meanings for standard beeps programmed into the scanner. Other applications written for the scanner can have their own beep sequences and therefore are not listed in this table. See your System Administrator for beep sequences and their meanings.

For additional information on Error Codes, see Communication Errors on page 3-5.

Table 4-4. Beeper Indications

Beeper Sequence Indication Default Application

Short high tone A bar code symbol was decoded (if decode beeper is enabled).

N/A

4 Beeps - long low A host transmission error occurred. Data was not successfully sent to the host device. This occurs if a unit is not properly configured. Check option settings.

Error code 003 Error code 009 Error code 018 Error code 247 Error code 249 Error code 253

5 Beeps - low tone Convert or format error. Error code 002 Error code 008

Hi/Hi/Hi/Lo tone RS-232 receive error. Error code 005

4 Beeps - short Hi Battery requires recharging. Low Battery

4 Beeps - Lo/Hi/Lo/Hi An RF transmission error has occurred. Move closer to the cradle and re-scan the bar code.

Error code 015 Error code 016 Error code 017 Error code 024

Short high tone Correct entry scanned or correct menu sequence performed.

N/A

Show 4 more labels / short text on this page
Maintenance And Specifications · Error Codes · Standard Use · Parameter Menu Scanning
Page 68 of the Symbol Technologies P470 user manual — N/A
Pagina 68 · klik om te vergroten
Pagina 68

Table 4-4. Beeper Indications (Continued)

Beeper Sequence Indication Default Application

Long Lo/Long Hi tone Input error, incorrect bar code or

N/A

“Cancel” scanned, wrong entry, incorrect bar code programming sequence; remain in program mode.

Hi/Lo tone Keyboard parameter selected. Enter value using bar code keypad.

N/A

Hi/Lo/Hi/Lo tone Successful program exit with change in the parameter setting.

N/A

4 Beeps - Lo/Hi/Lo/Hi followed by 2 Beeps - Lo/Hi

Correct entry scanned or correct menu sequence performed in the scanner but communication error with cradle has occurred.

N/A

Error Codes

Page 69 of the Symbol Technologies P470 user manual — Operational Parameters
Pagina 69 · klik om te vergroten
Pagina 69

Chapter 5 Parameter Menus

Introduction

This chapter has the optional parameter bar codes necessary to program the RF scanner.

Operational Parameters

The RF scanner is shipped with the settings shown in Table 5-1. These default values are stored in non-volatile memory and are preserved even when the scanner is powered down. You can change these default values by scanning the appropriate bar codes included in this manual. These new values replace the standard default values in memory. The default parameter values can be recalled by scanning the bar code in the section Set Default Parameter on page 5-7.

The scanner automatically detects which cable it is attached to, either an RS-232 or a Synapse cable. If it is attached to an RS-232 cable and has either an ICL, Nixdorf, or Fujitsu host interface, then scan the appropriate bar code from page 5-10 after power up. Any other RS-232 host interface works with the default setting.

If it is attached to a Synapse cable, plug everything together as described on page 2-3 and then follow the directions that come with the Synapse cable for setting up the host interface.

Page 70 of the Symbol Technologies P470 user manual — Table 5-1. Default Tabl e
Pagina 70 · klik om te vergroten
Pagina 70

The following table lists the defaults for all parameters. If you wish to change any option, scan the appropriate bar code(s). An asterisk (*) next to a bar code indicates the default.

Table 5-1. Default Tabl e

Parameter Default Page Number

Set Default Parameter All Defaults 5-7

Scan & Transmit Application RS232/Synapse 5-8

RS-232 Host Type Standard 5-9

Host Response Timeout 5 seconds 5-12

RF Channel No Default Setting 5-13

RF Retries 4 5-13

Sleep Time 10 seconds 5-15

Decimal Separator Decimal Point (.) 5-16

Key Click Enabled 5-17

Beeper Tone High Frequency 5-18

Beeper Volume High 5-19

Power Detect Beep Enabled 5-20

Beep After Good Decode Enabled 5-21

Laser On Time 3.0 seconds 5-22

Transmit “No Read” Message Disabled 5-23

Linear Code Type Security Levels 1 5-24

Bi-directional Redundancy Disabled 5-26

Autodiscriminate Response Time 1.0 second 5-27

Communication Protocol · Beeper Options · Decode Options

Page 71 of the Symbol Technologies P470 user manual — UPC/EAN
Pagina 71 · klik om te vergroten
Pagina 71

Table 5-1. Default Table (Continued)

Parameter Default Page Number

UPC/EAN

Bookland EAN Disabled 5-30

Decode UPC/EAN Supplementals Ignore 5-31

Decode UPC/EAN Supplemental Redundancy

Transmit UPC-A Check Digit Enabled 5-33

Transmit UPC-E Check Digit Enabled 5-33

Transmit UPC-E1 Check Digit Enabled 5-33

UPC-A Preamble System Character 5-34

UPC-E Preamble System Character 5-35

UPC-E1 Preamble System Character 5-36

Convert UPC-E to A Disabled 5-37

Convert UPC-E1 to A Disabled 5-38

EAN-8 Zero Extend Disabled 5-39

Convert EAN-8 to EAN-13 Type Type is EAN-13 5-40

UPC/EAN Security Levels 0 5-41

UPC/EAN Coupon Code Disabled 5-43

Show 6 more labels / short text on this page
Parameter Menus · UPC-A Enabled 5-28 · UPC-E Enabled 5-28 · UPC-E1 Disabled 5-28 · EAN-8 Enabled 5-29 · EAN-13 Enabled 5-29
Page 72 of the Symbol Technologies P470 user manual — Table 5-1. Default Table (Continued)
Pagina 72 · klik om te vergroten
Pagina 72

Table 5-1. Default Table (Continued)

Parameter Default Page Number

Code 128 Enabled 5-44

Code 39 Enabled 5-46

Trioptic Code 39 Disabled 5-47

Set Length(s) for Code 39 2 to 55 5-49

Code 39 Check Digit Verification Disabled 5-50

Transmit Code 39 Check Digit Disabled 5-51

Code 39 Full ASCII Conversion Disabled 5-52

Convert Code 39 to Code 32 Disabled 5-53

Code 32 Prefix Disabled 5-54

Code 93 Disabled 5-55

Set Length(s) for Code 93 4-55 5-56

Interleaved 2 of 5

Interleaved 2 of 5 Enabled 5-58

Set Length(s) for I 2 of 5 14 5-59

I 2 of 5 Check Digit Verification Disabled 5-61

Transmit I 2 of 5 Check Digit Disabled 5-62

Convert I 2 of 5 to EAN 13 Disabled 5-63

Show 4 more labels / short text on this page
Code 128 · UCC/EAN-128 Enabled 5-45 · Code 39 · Code 93
Page 73 of the Symbol Technologies P470 user manual — Table 5-1. Default Table (Continued)
Pagina 73 · klik om te vergroten
Pagina 73

Table 5-1. Default Table (Continued)

Parameter Default Page Number

Discrete 2 of 5

Discrete 2 of 5 Disabled 5-64

Set Length(s) for D 2 of 5 12 5-65

Set Lengths for Codabar 5-55 5-69

CLSI Editing Disabled 5-70

NOTIS Editing Disabled 5-71

MSI Plessey Disabled 5-72

Set Length(s) for MSI Plessey Any Length 5-74

MSI Plessey Check Digits One 5-75

Transmit MSI Plessey Check Digit Disabled 5-76

MSI Plessey Check Digit Algorithm Mod 10/Mod 10 5-77

Transmit Code ID Character None 5-79

Show 5 more labels / short text on this page
Parameter Menus · Codabar · Codabar Disabled 5-67 · MSI Plessey · Data Options
Page 74 of the Symbol Technologies P470 user manual — RS-232C
Pagina 74 · klik om te vergroten
Pagina 74

Table 5-1. Default Table (Continued)

Parameter Default Page Number

RS-232C

RS-232 Parameters Standard 5-81

Baud Rate 9600 5-82

Check Receive Errors Disabled 5-85

Hardware Handshaking None 5-87

Software Handshaking None 5-88

Host Serial Response Time-out 2 Sec. 5-90

RTS Line State (cable use only) Low 5-91

Stop Bit Select 1 5-92

ASCII Format 8-Bit 5-92

Intercharacter Delay 0 5-93

MCL-Net Baud Rate 38400 5-93

MCL-Net Hex Addressing Mode Disabled 5-96

Scanner Address 001 5-97

MCL-Net Transmit Retries 3 5-97

MCL-Net Frame Timeout 500 ms 5-97

Scanner Decode Beep Type 1 5-98

Long Range Scanning Bar Codes

Aim Mode Sequential trigger/Aim 5-99

Aim Duration 0.8 Sec 5-100

Parity None 5-83 · MCL-Net

Page 75 of the Symbol Technologies P470 user manual — SET ALL DEFAULTS
Pagina 75 · klik om te vergroten
Pagina 75

Set Default Parameter

Scanning this bar code returns all parameters to the values listed in Table 5-1 (factory settings), but does not erase any programmed ADF rules.

SET ALL DEFAULTS

Parameter Menus

Page 76 of the Symbol Technologies P470 user manual — *RS232/SYNAPSE
Pagina 76 · klik om te vergroten
Pagina 76

Communication Protocol

The bar codes below set the communication protocol used by the Scan & Transmit default application.

The communication options are RS232/Synapse or MCL-Net. If you select RS232/ Synapse, the scanner automatically identifies whether an RS232 or Synapse interface is required. MCL-Net allows the scanner to communicate with a host running MCL-Link or MCL-Link Lite.

Scan & Transmit Application

This communication protocol is used for the real time scanning and transmission of data to a host when a cable is attached to the cradle.

*RS232/SYNAPSE

MCL-NET

default applications and will not work with applications created with MCL-Designer.

Page 77 of the Symbol Technologies P470 user manual — Table 5-2. Terminal Specific RS-232C
Pagina 77 · klik om te vergroten
Pagina 77

Host Type

RS-232C Host Types

Most RS-232C hosts work fine with the default settings, however, three RS-232C hosts are set up with their own parameter default settings. Selecting the ICL, Fujitsu or Nixdorf RS- 232C host interface sets the defaults listed below. These defaults take precedence over Standard RS-232 defaults. So, if you select the Fujitsu RS-232C first, and then select the Standard RS-232 defaults, the Fujitsu defaults still take precedence. To return to the factory set defaults, scan the SET ALL DEFAULTS bar code on page 5-7.

Table 5-2. Terminal Specific RS-232C

NIXDORF

Parameter Standard ICL FUJITSU

Transmit Code ID No Yes Yes Yes

Data Transmission Format Data as is Data/Suffix Data/Suffix Data/Suffix

Suffix CR/LF CR CR CR

Baud Rate 9600

Parity None Even None Odd

Hardware Handshaking None RTS/CTS Option 3

None RTS/CTS Option 3

Software Handshaking None

Serial Response Time-out 2 Sec. 9.9 Sec. 2 Sec. 9.9 Sec.

Stop Bit Select One

ASCII Format 8-Bit

Beep On <BEL> Disabled

RTS Line State Low High Low *Low = No data to send

*In the Nixdorf Mode B, if CTS is Low, transmission of scan data is disabled. When CTS is High, bar code data is transmitted to the host.

Parameter Menus · Mode A/ · Mode B

Page 78 of the Symbol Technologies P470 user manual — FUJITSU RS-232C
Pagina 78 · klik om te vergroten
Pagina 78

Scan the appropriate bar code below to select an RS-232C Host Interface.

Symbol Technologies P470 — Host Type diagram (page 78)
Afb. 9 · Host Type

*STANDARD RS-232C

Symbol Technologies P470 — *STANDARD RS-232C diagram (page 78)
Afb. 10

ICL RS-232C

Symbol Technologies P470 — ICL RS-232C diagram (page 78)
Afb. 11

NIXDORF RS-232C Mode A

Symbol Technologies P470 — ICL RS-232C diagram (page 78)
Afb. 12

NIXDORF RS-232C Mode B

Symbol Technologies P470 — ICL RS-232C diagram (page 78)
Afb. 13

FUJITSU RS-232C

OPOS

Page 79 of the Symbol Technologies P470 user manual — Table 5-3. Terminal Specific Code ID Characters
Pagina 79 · klik om te vergroten
Pagina 79

Code ID Characters for RS232C Host Types

Selecting the ICL, Fujitsu, or Nixdorf RS-232C host interface enables the transmission of Code ID Characters as listed below. These Code ID Characters are not programmable and are separate from the Transmit Code ID feature. The Transmit Code ID feature should not be enabled for these hosts.

Table 5-3. Terminal Specific Code ID Characters

ICL FUJITSU NIXDORF

UPC-A “A” “A” “A”

UPC-E “E” “E” “C0”

EAN-8 “FF” “FF” “B”

EAN-13 “F” “F” “A”

Code 39 “C” None “M”

Codabar “N” None “N”

Code 128 “L” None “K”

I 2 of 5 “I” None “I”

Code 93 None None “L”

D 2 of 5 “H” None “H”

UCC/EAN 128 “L” None “P”

MSI/Plessey None None “O”

Bookland EAN “F” “F” “A”

Trioptic None None None

Parameter Menus

Page 80 of the Symbol Technologies P470 user manual — Host Response Timeout
Pagina 80 · klik om te vergroten
Pagina 80

Host Response Timeout

This parameter indicates how long the scanner will wait for a response from the cradle, after the cradle has sent its data to the attached host device. The timeout ranges from 5 seconds to 64 seconds, in 1 second increments. The default is 5 seconds.To change the timeout value, scan the bar code below, then scan two bar codes using the Numeric Bar Codes on page 5-101.

HOST RESPONSE TIMEOUT (RANGE OF 5 TO 64 SECONDS)

Page 81 of the Symbol Technologies P470 user manual — 3 RETRIES
Pagina 81 · klik om te vergroten
Pagina 81

RF Channel

Selects the RF channel used for radio transmissions and reception. The channel ranges are nation dependent (see Appendix C, Radio Channels for a list of Channel Availability by Country). To enter a range, scan the bar code below followed by 2 digits from the numeric bar code section (starting on page 5-101) to set the desired channel. If the channel is not legal for your country, an error beep will be heard instead of a successful warble. It is recommended that each scanner/cradle pair be set to a different channel than neighboring scanner/cradle pairs.

RF Retries

On a transmission, the radio will try to send the data a certain number of times prior to giving up if the receiving cradle is not responding. The following parameter allows the user to select how many retries should be tried. For additional information, see Increase the number of RF Retries on page 2-8.

3 RETRIES

*4 RETRIES

Parameter Menus · RF Channel

Page 82 of the Symbol Technologies P470 user manual — RF Channel
Pagina 82 · klik om te vergroten
Pagina 82
Symbol Technologies P470 — RF Channel diagram (page 82)
Afb. 14 · RF Channel
Page 83 of the Symbol Technologies P470 user manual — SLEEP TIME (RANGE OF 5 TO 32 SECONDS)
Pagina 83 · klik om te vergroten
Pagina 83

Sleep Time

Scan the bar code below to select how long the scanner will “stay awake” (not power down) in seconds after a trigger pull or a key press. First scan this bar code, then enter a range from 05 to 32, using the Numeric Bar Codes on page 5-101. It can stay awake from 5 seconds to 32 seconds.

programmed may affect the battery life time for that session before needing a charge.

Symbol Technologies P470 — Sleep Time diagram (page 83)
Afb. 15 · Sleep Time

SLEEP TIME (RANGE OF 5 TO 32 SECONDS)

Parameter Menus

Page 84 of the Symbol Technologies P470 user manual — COMMA (,)
Pagina 84 · klik om te vergroten
Pagina 84

Decimal Separator

Scan the appropriate bar code below to select what separator to display when you hit the decimal point key on the keypad. Choose DECIMAL POINT (.) or COMMA (,).

Symbol Technologies P470 — Decimal Separator diagram (page 84)
Afb. 16 · Decimal Separator

*DECIMAL POINT (.)

Symbol Technologies P470 — *DECIMAL POINT (.) diagram (page 84)
Afb. 17

COMMA (,)

Page 85 of the Symbol Technologies P470 user manual — DISABLE
Pagina 85 · klik om te vergroten
Pagina 85

Key Click

Scan the appropriate bar code below to select whether the keypad click is enabled or not. Choose ENABLE or DISABLE.

Symbol Technologies P470 — Key Click diagram (page 85)
Afb. 18 · Key Click

*ENABLE

Symbol Technologies P470 — *ENABLE diagram (page 85)
Afb. 19

DISABLE

Parameter Menus

Page 86 of the Symbol Technologies P470 user manual — *HIGH FREQUENCY
Pagina 86 · klik om te vergroten
Pagina 86

Beeper Tone

Scan the appropriate bar code below to select a decode beep frequency (tone). Choose LOW FREQUENCY, MEDIUM FREQUENCY, or HIGH FREQUENCY.

Symbol Technologies P470 — Beeper Tone diagram (page 86)
Afb. 20 · Beeper Tone

LOW FREQUENCY

Symbol Technologies P470 — LOW FREQUENCY diagram (page 86)
Afb. 21

MEDIUM FREQUENCY

Symbol Technologies P470 — MEDIUM FREQUENCY diagram (page 86)
Afb. 22

*HIGH FREQUENCY

Page 87 of the Symbol Technologies P470 user manual — *HIGH VOLUME
Pagina 87 · klik om te vergroten
Pagina 87

Beeper Volume

Scan the appropriate bar code below to select a beeper volume. Choose LOW VOLUME, MEDIUM VOLUME, or HIGH VOLUME.

Symbol Technologies P470 — Beeper Volume diagram (page 87)
Afb. 23 · Beeper Volume

LOW VOLUME

Symbol Technologies P470 — LOW VOLUME diagram (page 87)
Afb. 24

MEDIUM VOLUME

Symbol Technologies P470 — MEDIUM VOLUME diagram (page 87)
Afb. 25

*HIGH VOLUME

Parameter Menus

Page 88 of the Symbol Technologies P470 user manual — POWER DETECT BEEP DISABLED
Pagina 88 · klik om te vergroten
Pagina 88

Power Detect Beep

Scan the appropriate barcode below to enable or disable the Power Detection Beep.

POWER DETECT BEEP DISABLED

*POWER DETECT BEEP ENABLED

Page 89 of the Symbol Technologies P470 user manual — DO NOT BEEP AFTER GOOD DECODE
Pagina 89 · klik om te vergroten
Pagina 89

Beep After Good Decode

Scan the appropriate bar code below to select whether or not the scanner beeps after a good decode. If DO NOT BEEP is selected, the beeper still operates during parameter menu scanning and indicates error conditions.

Symbol Technologies P470 — Beep After Good Decode diagram (page 89)
Afb. 26 · Beep After Good Decode

*BEEP AFTER GOOD DECODE

Symbol Technologies P470 — *BEEP AFTER GOOD DECODE diagram (page 89)
Afb. 27

DO NOT BEEP AFTER GOOD DECODE

Parameter Menus

Page 90 of the Symbol Technologies P470 user manual — LASER ON TIME
Pagina 90 · klik om te vergroten
Pagina 90

Laser On Time

This parameter sets the maximum time decode processing continues during a scan attempt. It is programmable in 0.1 second increments from 0.5 to 9.9 seconds.

Scan the bar code below to set a Laser On Time. Next scan two numeric bar codes beginning on page 5-101 that correspond to the desired time. Time less than 1.0 second must have a leading zero. For example, to set a Time On of 0.5 seconds, scan the bar code below, then scan the “0” and “5” bar codes. If you make an error, or wish to change your selection, scan CANCEL on page 5-103.

may affect the battery life time for that session before needing a charge.

Symbol Technologies P470 — Laser On Time diagram (page 90)
Afb. 28 · Laser On Time

LASER ON TIME

Page 91 of the Symbol Technologies P470 user manual — *DISABLE NO READ
Pagina 91 · klik om te vergroten
Pagina 91

Transmit “No Read” Message

Scan the appropriate bar code below to select whether or not a “No Read” message is transmitted. When enabled, if a symbol does not decode, “NR” is transmitted. When disabled, if a symbol does not read, nothing is sent to the host.

Symbol Technologies P470 — Transmit “No Read” Message diagram (page 91)
Afb. 29 · Transmit “No Read” Message

ENABLE NO READ

Symbol Technologies P470 — ENABLE NO READ diagram (page 91)
Afb. 30

*DISABLE NO READ

Parameter Menus

Page 92 of the Symbol Technologies P470 user manual — LINEAR SECURITY LEVEL 2
Pagina 92 · klik om te vergroten
Pagina 92

Linear Code Type Security Level

The scanner offers four levels of decode security for linear code types (e.g., Code 39, Interleaved 2 of 5). Higher security levels are selected for decreasing levels of bar code quality. As security levels increase, the scanner’s aggressiveness decreases.

Select the security level appropriate for your bar code quality.

Linear Security Level 1

The following code types must be successfully read twice before being decoded:

MSI Plessey 4 or less

D 2 of 5 8 or less

I 2 of 5 8 or less

Symbol Technologies P470 — Linear Security Level 1 diagram (page 92)
Afb. 31 · Linear Security Level 1

*LINEAR SECURITY LEVEL 1

Linear Security Level 2

All code types must be successfully read twice before being decoded.

Symbol Technologies P470 — *LINEAR SECURITY LEVEL 1 diagram (page 92)
Afb. 32

LINEAR SECURITY LEVEL 2

Code Type Length · Codabar All

Page 93 of the Symbol Technologies P470 user manual — LINEAR SECURITY LEVEL 4
Pagina 93 · klik om te vergroten
Pagina 93

Linear Code Type Security Level (Continued)

Linear Security Level 3

Code types other than the following must be successfully read twice before being decoded. The following codes must be read three times:

MSI Plessey 4 or less

D 2 of 5 8 or less

I 2 of 5 8 or less

Symbol Technologies P470 — Linear Code Type Security Level (Continued) diagram (page 93)
Afb. 33 · Linear Code Type Security Level (Continued)

LINEAR SECURITY LEVEL 3

Linear Security Level 4

All code types must be successfully read three times before being decoded.

Symbol Technologies P470 — LINEAR SECURITY LEVEL 3 diagram (page 93)
Afb. 34

LINEAR SECURITY LEVEL 4

Parameter Menus · Code Type Length

Page 94 of the Symbol Technologies P470 user manual — *DISABLE BI-DIRECTIONAL REDUNDANCY
Pagina 94 · klik om te vergroten
Pagina 94

Bi-directional Redundancy

This parameter is only valid when a Linear Code Type Security Level (see page 5-24) is enabled. When this parameter is enabled, a bar code must be successfully scanned in both directions (forward and reverse) before being decoded.

Symbol Technologies P470 — Bi-directional Redundancy diagram (page 94)
Afb. 35 · Bi-directional Redundancy

ENABLE BI-DIRECTIONAL REDUNDANCY

Symbol Technologies P470 — ENABLE BI-DIRECTIONAL REDUNDANCY diagram (page 94)
Afb. 36

*DISABLE BI-DIRECTIONAL REDUNDANCY

Page 95 of the Symbol Technologies P470 user manual — Autodiscriminate Response Time
Pagina 95 · klik om te vergroten
Pagina 95

Autodiscriminate Response Time

This parameter extends the length of time during which the scanner tries to detect which host it is connected to on power up.

must be used.

Symbol Technologies P470 — Autodiscriminate Response Time diagram (page 95)
Afb. 37 · Autodiscriminate Response Time
Symbol Technologies P470 — Autodiscriminate Response Time diagram (page 95)
Afb. 38 · Autodiscriminate Response Time

Parameter Menus · *1 second · 5 seconds

Page 96 of the Symbol Technologies P470 user manual — ENABLE UPC-E1 *DISABLE UPC-E1
Pagina 96 · klik om te vergroten
Pagina 96

Enable/Disable UPC-E/UPC-A/UPC-E1

Scan the appropriate bar code below to enable or disable UPC-E or UPC-A.

Symbol Technologies P470 — Enable/Disable UPC-E/UPC-A/UPC-E1 diagram (page 96)
Afb. 39 · Enable/Disable UPC-E/UPC-A/UPC-E1
Symbol Technologies P470 — Enable/Disable UPC-E/UPC-A/UPC-E1 diagram (page 96)
Afb. 40 · Enable/Disable UPC-E/UPC-A/UPC-E1

*ENABLE UPC-E DISABLE UPC-E

Symbol Technologies P470 — *ENABLE UPC-E DISABLE UPC-E diagram (page 96)
Afb. 41
Symbol Technologies P470 — *ENABLE UPC-E DISABLE UPC-E diagram (page 96)
Afb. 42

*ENABLE UPC-A DISABLE UPC-A

Symbol Technologies P470 — *ENABLE UPC-A DISABLE UPC-A diagram (page 96)
Afb. 43
Symbol Technologies P470 — *ENABLE UPC-A DISABLE UPC-A diagram (page 96)
Afb. 44

ENABLE UPC-E1 *DISABLE UPC-E1

Page 97 of the Symbol Technologies P470 user manual — DISABLE EAN-13
Pagina 97 · klik om te vergroten
Pagina 97

Enable/Disable EAN-8/EAN-13

Scan the appropriate bar code below to enable or disable EAN-8 or EAN-13.

Symbol Technologies P470 — Enable/Disable EAN-8/EAN-13 diagram (page 97)
Afb. 45 · Enable/Disable EAN-8/EAN-13

*ENABLE EAN-8

Symbol Technologies P470 — *ENABLE EAN-8 diagram (page 97)
Afb. 46

DISABLE EAN-8

Symbol Technologies P470 — DISABLE EAN-8 diagram (page 97)
Afb. 47

*ENABLE EAN-13

Symbol Technologies P470 — *ENABLE EAN-13 diagram (page 97)
Afb. 48

DISABLE EAN-13

Parameter Menus

Page 98 of the Symbol Technologies P470 user manual — *DISABLE BOOKLAND EAN
Pagina 98 · klik om te vergroten
Pagina 98

Enable/Disable Bookland EAN

Scan the appropriate bar code below to enable or disable Bookland EAN.

Symbol Technologies P470 — Enable/Disable Bookland EAN diagram (page 98)
Afb. 49 · Enable/Disable Bookland EAN

ENABLE BOOKLAND EAN

Symbol Technologies P470 — ENABLE BOOKLAND EAN diagram (page 98)
Afb. 50

*DISABLE BOOKLAND EAN

Page 99 of the Symbol Technologies P470 user manual — AUTODISCRIMINATE UPC/EAN SUPPLEMENTALS
Pagina 99 · klik om te vergroten
Pagina 99

Decode UPC/EAN Supplementals

Supplementals are characters (either 2 or 5) that are added on according to specific code format conventions (e.g., UPC A+2, UPC E+2, EAN 8+2). Three options are available.

  • If Decode UPC/EAN with supplementals is selected, UPC/EAN symbols without supplemental characters are not decoded.
  • If Ignore UPC/EAN with supplementals is selected, UPC/EAN symbols with supplemental characters are decoded and the supplemental characters are ignored.
  • If Autodiscriminate UPC/EAN supplementals is selected, UPC/EAN symbols, either with or without supplementals, are decoded. If selected, choose an appropriate Decode UPC/EAN Supplemental Redundancy value from the next page.

read or ignore supplemental characters.

Symbol Technologies P470 — Decode UPC/EAN Supplementals diagram (page 99)
Afb. 51 · Decode UPC/EAN Supplementals

DECODE UPC/EAN WITH SUPPLEMENTALS

Symbol Technologies P470 — DECODE UPC/EAN WITH SUPPLEMENTALS diagram (page 99)
Afb. 52

*IGNORE UPC/EAN WITH SUPPLEMENTALS

Symbol Technologies P470 — *IGNORE UPC/EAN WITH SUPPLEMENTALS diagram (page 99)
Afb. 53

AUTODISCRIMINATE UPC/EAN SUPPLEMENTALS

Parameter Menus

Page 100 of the Symbol Technologies P470 user manual — DECODE UPC/EAN SUPPLEMENTAL REDUNDANCY
Pagina 100 · klik om te vergroten
Pagina 100

Decode UPC/EAN Supplemental Redundancy

With Autodiscriminate UPC/EAN Supplementals selected, this option adjusts the number of times a symbol without supplementals is decoded before transmission. The range is from two to 20 times. Five or above is recommended when decoding a mix of UPC/EAN symbols with and without supplementals, and the autodiscriminate option is selected.

Scan the bar code below to select a decode redundancy value. Next scan two numeric bar codes beginning on page 5-101. Single digit numbers must have a leading zero. If you make an error, or wish to change your selection, scan CANCEL on page 5-103.

Symbol Technologies P470 — Decode UPC/EAN Supplemental Redundancy diagram (page 100)
Afb. 54 · Decode UPC/EAN Supplemental Redundancy

DECODE UPC/EAN SUPPLEMENTAL REDUNDANCY

Page 101 of the Symbol Technologies P470 user manual — DO NOT TRANSMIT UPC-E1 CHECK DIGIT
Pagina 101 · klik om te vergroten
Pagina 101

Transmit UPC-A/UPC-E/UPC-E1 Check Digit

Scan the appropriate bar code below to transmit the symbol with or without the UPC-A, UPC-E, or UPC-E1 check digit.

Symbol Technologies P470 — Transmit UPC-A/UPC-E/UPC-E1 Check Digit diagram (page 101)
Afb. 55 · Transmit UPC-A/UPC-E/UPC-E1 Check Digit

*TRANSMIT UPC-A CHECK DIGIT

Symbol Technologies P470 — *TRANSMIT UPC-A CHECK DIGIT diagram (page 101)
Afb. 56

DO NOT TRANSMIT UPC-A CHECK DIGIT

Symbol Technologies P470 — DO NOT TRANSMIT UPC-A CHECK DIGIT diagram (page 101)
Afb. 57

*TRANSMIT UPC-E CHECK DIGIT

Symbol Technologies P470 — *TRANSMIT UPC-E CHECK DIGIT diagram (page 101)
Afb. 58

DO NOT TRANSMIT UPC-E CHECK DIGIT

Symbol Technologies P470 — DO NOT TRANSMIT UPC-E CHECK DIGIT diagram (page 101)
Afb. 59

*TRANSMIT UPC-E1 CHECK DIGIT

Symbol Technologies P470 — *TRANSMIT UPC-E1 CHECK DIGIT diagram (page 101)
Afb. 60

DO NOT TRANSMIT UPC-E1 CHECK DIGIT

Parameter Menus

Page 102 of the Symbol Technologies P470 user manual — *SYSTEM CHARACTER (<SYSTEM CHARACTER> <DATA>)
Pagina 102 · klik om te vergroten
Pagina 102

UPC-A Preamble

Three options are given for lead-in characters for UPC-A symbols transmitted to the host device: transmit system character only, transmit system character and country code (“0” for USA), and no preamble transmitted. The lead-in characters are considered part of the symbol.

Symbol Technologies P470 — UPC-A Preamble diagram (page 102)
Afb. 61 · UPC-A Preamble

NO PREAMBLE

(<DATA>)

Symbol Technologies P470 — NO PREAMBLE diagram (page 102)
Afb. 62

*SYSTEM CHARACTER (<SYSTEM CHARACTER> <DATA>)

Symbol Technologies P470 — *SYSTEM CHARACTER (<SYSTEM CHARACTER> <DATA>) diagram (page 102)
Afb. 63

SYSTEM CHARACTER & COUNTRY CODE (< COUNTRY CODE> <SYSTEM CHARACTER> <DATA>)

Page 103 of the Symbol Technologies P470 user manual — *SYSTEM CHARACTER (<SYSTEM CHARACTER> <DATA>)
Pagina 103 · klik om te vergroten
Pagina 103

UPC-E Preamble

Three options are given for lead-in characters for UPC-E symbols transmitted to the host device: Transmit system character only, transmit system character and country code (“0” for USA), and no preamble transmitted. The lead-in characters are considered part of the symbol.

Symbol Technologies P470 — UPC-E Preamble diagram (page 103)
Afb. 64 · UPC-E Preamble

NO PREAMBLE

(<DATA>)

Symbol Technologies P470 — NO PREAMBLE diagram (page 103)
Afb. 65

*SYSTEM CHARACTER (<SYSTEM CHARACTER> <DATA>)

Symbol Technologies P470 — *SYSTEM CHARACTER (<SYSTEM CHARACTER> <DATA>) diagram (page 103)
Afb. 66

SYSTEM CHARACTER & COUNTRY CODE (< COUNTRY CODE> <SYSTEM CHARACTER> <DATA>)

Parameter Menus

Page 104 of the Symbol Technologies P470 user manual — *SYSTEM CHARACTER (<SYSTEM CHARACTER> <DATA>)
Pagina 104 · klik om te vergroten
Pagina 104

UPC-E1 Preamble

Three options are given for lead-in characters for UPC-E1 symbols transmitted to the host device: Transmit system character only, transmit system character and country code (“0” for USA), and no preamble transmitted. The lead-in characters are considered part of the symbol.

Symbol Technologies P470 — UPC-E1 Preamble diagram (page 104)
Afb. 67 · UPC-E1 Preamble

NO PREAMBLE

(<DATA>)

Symbol Technologies P470 — NO PREAMBLE diagram (page 104)
Afb. 68

*SYSTEM CHARACTER (<SYSTEM CHARACTER> <DATA>)

Symbol Technologies P470 — *SYSTEM CHARACTER (<SYSTEM CHARACTER> <DATA>) diagram (page 104)
Afb. 69

SYSTEM CHARACTER & COUNTRY CODE (< COUNTRY CODE> <SYSTEM CHARACTER> <DATA>)

Page 105 of the Symbol Technologies P470 user manual — *DO NOT CONVERT UPC-E TO UPC-A (DISABLE)
Pagina 105 · klik om te vergroten
Pagina 105

Convert UPC-E to UPC-A

This parameter converts UPC-E (zero suppressed) decoded data to UPC-A format before transmission. After conversion, data follows UPC-A format and is affected by UPC-A programming selections (e.g., Preamble, Check Digit).

Scanning DO NOT CONVERT UPC-E TO UPC-A allows you to transmit UPC-E (zero suppressed) decoded data.

Symbol Technologies P470 — Convert UPC-E to UPC-A diagram (page 105)
Afb. 70 · Convert UPC-E to UPC-A

CONVERT UPC-E TO UPC-A

(ENABLE)

Symbol Technologies P470 — CONVERT UPC-E TO UPC-A diagram (page 105)
Afb. 71

*DO NOT CONVERT UPC-E TO UPC-A (DISABLE)

Parameter Menus

Page 106 of the Symbol Technologies P470 user manual — *DO NOT CONVERT UPC-E1 TO UPC-A (DISABLE)
Pagina 106 · klik om te vergroten
Pagina 106

Convert UPC-E1 to UPC-A

This parameter converts UPC-E1 decoded data to UPC-A format before transmission. After conversion, data follows UPC-A format and is affected by UPC-A programming selections (e.g., Preamble, Check Digit).

Scanning DO NOT CONVERT UPC-E1 TO UPC-A allows you to transmit UPC-E1 decoded data.

Symbol Technologies P470 — Convert UPC-E1 to UPC-A diagram (page 106)
Afb. 72 · Convert UPC-E1 to UPC-A

CONVERT UPC-E1 TO UPC-A

(ENABLE)

Symbol Technologies P470 — CONVERT UPC-E1 TO UPC-A diagram (page 106)
Afb. 73

*DO NOT CONVERT UPC-E1 TO UPC-A (DISABLE)

Page 107 of the Symbol Technologies P470 user manual — *DISABLE EAN ZERO EXTEND
Pagina 107 · klik om te vergroten
Pagina 107

EAN-8 Zero Extend

If this parameter is enabled, five leading zeros are added to decoded EAN-8 symbols to make them compatible in format to EAN-13 symbols.

Disabling this parameter returns EAN-8 symbols to their normal format.

Symbol Technologies P470 — EAN-8 Zero Extend diagram (page 107)
Afb. 74 · EAN-8 Zero Extend

ENABLE EAN ZERO EXTEND

Symbol Technologies P470 — ENABLE EAN ZERO EXTEND diagram (page 107)
Afb. 75

*DISABLE EAN ZERO EXTEND

Parameter Menus

Page 108 of the Symbol Technologies P470 user manual — TYPE IS EAN-8
Pagina 108 · klik om te vergroten
Pagina 108

Convert EAN-8 to EAN-13 Type

When EAN Zero Extend is enabled, this parameter gives you the option of labeling the extended symbol as either an EAN-13 bar code, or an EAN-8 bar code.

When EAN Zero Extend is disabled, this parameter has no effect on bar code data.

Symbol Technologies P470 — Convert EAN-8 to EAN-13 Type diagram (page 108)
Afb. 76 · Convert EAN-8 to EAN-13 Type

*TYPE IS EAN-13

Symbol Technologies P470 — *TYPE IS EAN-13 diagram (page 108)
Afb. 77

TYPE IS EAN-8

Page 109 of the Symbol Technologies P470 user manual — UPC/EAN SECURITY LEVEL 1
Pagina 109 · klik om te vergroten
Pagina 109

UPC/EAN Security Level

The scanner offers four levels of decode security for UPC/EAN bar codes. Increasing levels of security are provided for decreasing levels of bar code quality. There is an inverse relationship between security and scanner aggressiveness, so be sure to choose only that level of security necessary for any given application.

UPC/EAN Security Level 0

This is the default setting which allows the scanner to operate in its most aggressive state, while providing sufficient security in decoding “in-spec” UPC/EAN bar codes.

Symbol Technologies P470 — UPC/EAN Security Level 0 diagram (page 109)
Afb. 78 · UPC/EAN Security Level 0

*UPC/EAN SECURITY LEVEL 0

UPC/EAN Security Level 1

As bar code quality levels diminish, certain characters become prone to mis-decodes before others (i.e., 1, 2, 7, 8). If you are experiencing mis-decodes of poorly printed bar codes, and the mis-decodes are limited to these characters, select this security level.

Symbol Technologies P470 — *UPC/EAN SECURITY LEVEL 0 diagram (page 109)
Afb. 79

UPC/EAN SECURITY LEVEL 1

Parameter Menus

Page 110 of the Symbol Technologies P470 user manual — UPC/EAN SECURITY LEVEL 3
Pagina 110 · klik om te vergroten
Pagina 110

UPC/EAN Security Level (Continued)

UPC/EAN Security Level 2

If you are experiencing mis-decodes of poorly printed bar codes, and the mis-decodes are not limited to characters 1, 2, 7, and 8, select this security level.

Symbol Technologies P470 — UPC/EAN Security Level (Continued) diagram (page 110)
Afb. 80 · UPC/EAN Security Level (Continued)

UPC/EAN SECURITY LEVEL 2

UPC/EAN Security Level 3

If you have tried Security Level 2, and are still experiencing misdecodes, select this security level. Be advised that selecting this option is an extreme measure against mis-decoding severely out of spec bar codes. Selection of this level of security significantly impairs the decoding ability of the scanner. If this level of security is necessary, you should try to improve the quality of your bar codes.

Symbol Technologies P470 — UPC/EAN SECURITY LEVEL 2 diagram (page 110)
Afb. 81

UPC/EAN SECURITY LEVEL 3

Page 111 of the Symbol Technologies P470 user manual — *DISABLE UPC/EAN COUPON CODE
Pagina 111 · klik om te vergroten
Pagina 111

UPC/EAN Coupon Code

When this parameter is enabled, the scanner decodes UPC-A, UPC-A with 2 supplemental characters, UPC-A with 5 supplemental characters, and UPC-A/EAN128 bar codes. AUTODISCRIMINATE UPC/EAN SUPPLEMENTALS on page 5-31 must be enabled.

Symbol Technologies P470 — UPC/EAN Coupon Code diagram (page 111)
Afb. 82 · UPC/EAN Coupon Code

ENABLE UPC/EAN COUPON CODE

Symbol Technologies P470 — ENABLE UPC/EAN COUPON CODE diagram (page 111)
Afb. 83

*DISABLE UPC/EAN COUPON CODE

Parameter Menus

Page 112 of the Symbol Technologies P470 user manual — DISABLE CODE 128
Pagina 112 · klik om te vergroten
Pagina 112

Enable/Disable Code 128

Scan the appropriate bar code below to enable or disable Code 128.

Symbol Technologies P470 — Enable/Disable Code 128 diagram (page 112)
Afb. 84 · Enable/Disable Code 128

*ENABLE CODE 128

Symbol Technologies P470 — *ENABLE CODE 128 diagram (page 112)
Afb. 85

DISABLE CODE 128

the barcode to be scanned when using Code 128.

Page 113 of the Symbol Technologies P470 user manual — DISABLE UCC/EAN-128
Pagina 113 · klik om te vergroten
Pagina 113

Enable/Disable UCC/EAN-128

Scan the appropriate bar code below to enable or disable UCC/EAN-128. (See Appendix A, Bar Code Information for details on UCC/EAN-128.)

Symbol Technologies P470 — Enable/Disable UCC/EAN-128 diagram (page 113)
Afb. 86 · Enable/Disable UCC/EAN-128

*ENABLE UCC/EAN-128

Symbol Technologies P470 — *ENABLE UCC/EAN-128 diagram (page 113)
Afb. 87

DISABLE UCC/EAN-128

Lengths for Code 128

No length setting is required for Code 128. The default setting is Any Length.

Parameter Menus

Page 114 of the Symbol Technologies P470 user manual — DISABLE CODE 39
Pagina 114 · klik om te vergroten
Pagina 114

Enable/Disable Code 39

Scan the appropriate bar code below to enable or disable Code 39.

Symbol Technologies P470 — Enable/Disable Code 39 diagram (page 114)
Afb. 88 · Enable/Disable Code 39

*ENABLE CODE 39

Symbol Technologies P470 — *ENABLE CODE 39 diagram (page 114)
Afb. 89

DISABLE CODE 39

Page 115 of the Symbol Technologies P470 user manual — *DISABLE TRIOPTIC CODE 39
Pagina 115 · klik om te vergroten
Pagina 115

Enable/Disable Trioptic Code 39

Trioptic Code 39 symbols always contain six characters. Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneously. If you get an error beep when enabling Trioptic Code 39, disable Code 39 Full ASCII and try again. To enable or disable Trioptic Code 39, scan the appropriate bar code below.

Symbol Technologies P470 — Enable/Disable Trioptic Code 39 diagram (page 115)
Afb. 90 · Enable/Disable Trioptic Code 39

ENABLE TRIOPTIC CODE 39

Symbol Technologies P470 — ENABLE TRIOPTIC CODE 39 diagram (page 115)
Afb. 91

*DISABLE TRIOPTIC CODE 39

Parameter Menus

Page 116 of the Symbol Technologies P470 user manual — CODE 39 - TWO DISCRETE LENGTHS
Pagina 116 · klik om te vergroten
Pagina 116

Set Lengths for Code 39

Lengths for Code 39 may be set for any length, one or two discrete lengths, or lengths within a specific range. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains. If Code 39 Full ASCII is enabled, Length Within a Range or Any Length are the preferred options.

One Discrete Length - This option allows you to decode only those codes containing a selected length. For example, if you select Code 39 One Discrete Length, then scan 1, 4, only Code 39 symbols containing 14 characters are decoded. Numeric bar codes begin on page 5-101. If you make an error, or wish to change your selection, scan CANCEL on page 5-103.

Symbol Technologies P470 — Set Lengths for Code 39 diagram (page 116)
Afb. 92 · Set Lengths for Code 39

CODE 39 - ONE DISCRETE LENGTH

Two Discrete Lengths - This option allows you to decode only those codes containing two selected lengths. For example, if you select Code 39 Two Discrete Lengths, then scan 0, 2, 1, 4, only Code 39 symbols containing 2 or 14 characters are decoded. Numeric bar codes begin on page 5-101. If you make an error, or wish to change your selection, scan CANCEL on page 5-103.

Symbol Technologies P470 — CODE 39 - ONE DISCRETE LENGTH diagram (page 116)
Afb. 93

CODE 39 - TWO DISCRETE LENGTHS

Page 117 of the Symbol Technologies P470 user manual — CODE 39 - ANY LENGTH
Pagina 117 · klik om te vergroten
Pagina 117

Set Lengths for Code 39 (Continued)

Length Within Range - This option allows you to decode a code type within a specified range. For example to decode Code 39 symbols containing between 4 and 12 characters, first scan Code 39 Length Within Range. Then scan 0, 4, 1 and 2 (single digit numbers must always be preceded by a leading zero). Numeric bar codes begin on page 5-101. If you make an error, or wish to change your selection, scan CANCEL on page 5-103.

Symbol Technologies P470 — Set Lengths for Code 39 (Continued) diagram (page 117)
Afb. 94 · Set Lengths for Code 39 (Continued)

CODE 39 - LENGTH WITHIN RANGE

Any Length - Scanning this option allows you to decode Code 39 symbols containing any number of characters.

Symbol Technologies P470 — CODE 39 - LENGTH WITHIN RANGE diagram (page 117)
Afb. 95

CODE 39 - ANY LENGTH

Parameter Menus

Page 118 of the Symbol Technologies P470 user manual — *DISABLE CODE 39 CHECK DIGIT
Pagina 118 · klik om te vergroten
Pagina 118

Code 39 Check Digit Verification

When enabled, this parameter checks the integrity of a Code 39 symbol to ensure it complies with specified algorithms.

Only those Code 39 symbols which include a modulo 43 check digit are decoded when this parameter is enabled.

Symbol Technologies P470 — Code 39 Check Digit Verification diagram (page 118)
Afb. 96 · Code 39 Check Digit Verification

ENABLE CODE 39 CHECK DIGIT

Symbol Technologies P470 — ENABLE CODE 39 CHECK DIGIT diagram (page 118)
Afb. 97

*DISABLE CODE 39 CHECK DIGIT

Page 119 of the Symbol Technologies P470 user manual — *DO NOT TRANSMIT CODE 39 CHECK DIGIT (DISABLE)
Pagina 119 · klik om te vergroten
Pagina 119

Transmit Code 39 Check Digit

Scan the appropriate bar code below to transmit the data with or without the check digit.

Symbol Technologies P470 — Transmit Code 39 Check Digit diagram (page 119)
Afb. 98 · Transmit Code 39 Check Digit

TRANSMIT CODE 39 CHECK DIGIT

(ENABLE)

Symbol Technologies P470 — TRANSMIT CODE 39 CHECK DIGIT diagram (page 119)
Afb. 99

*DO NOT TRANSMIT CODE 39 CHECK DIGIT (DISABLE)

Parameter Menus

Page 120 of the Symbol Technologies P470 user manual — *DISABLE CODE 39 FULL ASCII
Pagina 120 · klik om te vergroten
Pagina 120

Enable/Disable Code 39 Full ASCII

Scan the appropriate bar code below to enable or disable Code 39 Full ASCII.

When enabled, the ASCII character set assigns a code to letters, punctuation marks, numerals, and most control keystrokes on the keyboard.

The first 32 codes are non-printable and are assigned to keyboard control characters such as BACKSPACE and RETURN. The other 96 are called printable codes because all but SPACE and DELETE produce visible characters.

Code 39 Full ASCII interprets the bar code special character ($ + % /) preceding a Code 39 character and assigns an ASCII character value to the pair. For example, when Code 39 Full ASCII is enabled and a +B is scanned, it is interpreted as b, %J as ?, and $H emulates the keystroke BACKSPACE. Scanning ABC$M will output the keystroke equivalent of ABC ENTER. Refer to the ASCII table in Appendix A.

Code 39 Full ASCII and Trioptic Code 39 cannot be enabled simultaneously. If you get an error beep when enabling Code 39 Full ASCII, disable Trioptic Code 39 and try again.

The scanner does not autodiscriminate between Code 39 and Code 39 Full ASCII.

Symbol Technologies P470 — Enable/Disable Code 39 Full ASCII diagram (page 120)
Afb. 100 · Enable/Disable Code 39 Full ASCII

ENABLE CODE 39 FULL ASCII

Symbol Technologies P470 — ENABLE CODE 39 FULL ASCII diagram (page 120)
Afb. 101

*DISABLE CODE 39 FULL ASCII

the barcode to be scanned when using Code 39 Full ASCII.

Page 121 of the Symbol Technologies P470 user manual — CONVERT CODE 39 TO CODE 32
Pagina 121 · klik om te vergroten
Pagina 121

Convert Code 39 to Code 32

Scan the appropriate bar code below to enable or disable converting Code 39 to Code 32.

Symbol Technologies P470 — Convert Code 39 to Code 32 diagram (page 121)
Afb. 102 · Convert Code 39 to Code 32

CONVERT CODE 39 TO CODE 32

(ENABLE)

Symbol Technologies P470 — CONVERT CODE 39 TO CODE 32 diagram (page 121)
Afb. 103

*DO NOT CONVERT CODE 39 TO CODE 32 (DISABLE)

Parameter Menus

Page 122 of the Symbol Technologies P470 user manual — *DISABLE CODE 32 PREFIX
Pagina 122 · klik om te vergroten
Pagina 122

Code 32 Prefix

Scan the appropriate bar code below to enable or disable the prefix character “A” to all Code 32 bar codes.

function.

Symbol Technologies P470 — Code 32 Prefix diagram (page 122)
Afb. 104 · Code 32 Prefix

ENABLE CODE 32 PREFIX

Symbol Technologies P470 — ENABLE CODE 32 PREFIX diagram (page 122)
Afb. 105

*DISABLE CODE 32 PREFIX

Page 123 of the Symbol Technologies P470 user manual — *DISABLE CODE 93
Pagina 123 · klik om te vergroten
Pagina 123

Enable/Disable Code 93

Scan the appropriate bar code below to enable or disable Code 93.

Symbol Technologies P470 — Enable/Disable Code 93 diagram (page 123)
Afb. 106 · Enable/Disable Code 93

ENABLE CODE 93

Symbol Technologies P470 — ENABLE CODE 93 diagram (page 123)
Afb. 107

*DISABLE CODE 93

Parameter Menus

Page 124 of the Symbol Technologies P470 user manual — CODE 93 - TWO DISCRETE LENGTHS
Pagina 124 · klik om te vergroten
Pagina 124

Set Lengths for Code 93

Lengths for Code 93 may be set for any length, one or two discrete lengths, or lengths within a specific range. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s) the code contains.

One Discrete Length - This option allows you to decode only those codes containing a selected length. For example, if you select Code 93 One Discrete Length, then scan 1, 4, only Code 93 symbols containing 14 characters are decoded. Numeric bar codes begin on page 5-101. If you make an error, or wish to change your selection, scan CANCEL on page 5-103.

Symbol Technologies P470 — Set Lengths for Code 93 diagram (page 124)
Afb. 108 · Set Lengths for Code 93

CODE 93 - ONE DISCRETE LENGTH

Two Discrete Lengths - This option allows you to decode only those codes containing two selected lengths. For example, if you select Code 93 Two Discrete Lengths, then scan 0, 2, 1, 4, only Code 93 symbols containing 2 or 14 characters are decoded. Numeric bar codes begin on page 5-101. If you make an error, or wish to change your selection, scan CANCEL on page 5-103.

Symbol Technologies P470 — CODE 93 - ONE DISCRETE LENGTH diagram (page 124)
Afb. 109

CODE 93 - TWO DISCRETE LENGTHS

Page 125 of the Symbol Technologies P470 user manual — CODE 93 - ANY LENGTH
Pagina 125 · klik om te vergroten
Pagina 125

Set Lengths for Code 93 (Continued)

Length Within Range - This option allows you to decode a code type within a specified range. For example to decode Code 93 symbols containing between 4 and 12 characters, first scan Code 93 Length Within Range. Then scan 0, 4, 1 and 2 (single digit numbers must always be preceded by a leading zero). Numeric bar codes begin on page 5-101. If you make an error, or wish to change your selection, scan CANCEL on page 5-103.

Symbol Technologies P470 — Set Lengths for Code 93 (Continued) diagram (page 125)
Afb. 110 · Set Lengths for Code 93 (Continued)

CODE 93 - LENGTH WITHIN RANGE

Any Length - Scanning this option allows you to decode Code 93 symbols containing any number of characters.

Symbol Technologies P470 — CODE 93 - LENGTH WITHIN RANGE diagram (page 125)
Afb. 111

CODE 93 - ANY LENGTH

Parameter Menus

Page 126 of the Symbol Technologies P470 user manual — DISABLE INTERLEAVED 2 OF 5
Pagina 126 · klik om te vergroten
Pagina 126

Enable/Disable Interleaved 2 of 5

Scan the appropriate bar code below to enable or disable Interleaved 2 of 5.

Symbol Technologies P470 — Enable/Disable Interleaved 2 of 5 diagram (page 126)
Afb. 112 · Enable/Disable Interleaved 2 of 5

*ENABLE INTERLEAVED 2 OF 5

Symbol Technologies P470 — *ENABLE INTERLEAVED 2 OF 5 diagram (page 126)
Afb. 113

DISABLE INTERLEAVED 2 OF 5

Page 127 of the Symbol Technologies P470 user manual — Set Lengths for Interleaved 2 of 5
Pagina 127 · klik om te vergroten
Pagina 127

Set Lengths for Interleaved 2 of 5

Lengths for I 2 of 5 may be set for any length, one or two discrete lengths, or lengths within a specific range. The length of a code refers to the number of characters (i.e., human readable characters) the code contains and includes check digits.

One Discrete Length - This option allows you to decode only those codes containing a selected length. For example, if you select I 2 of 5 One Discrete Length, then scan 1, 4, the only I 2 of 5 symbols decoded are those containing 14 characters. Numeric bar codes begin on page 5-101. If you make an error, or wish to change your selection, scan CANCEL on page 5-103.

Symbol Technologies P470 — Set Lengths for Interleaved 2 of 5 diagram (page 127)
Afb. 114 · Set Lengths for Interleaved 2 of 5

I 2 of 5 - ONE DISCRETE LENGTH

Two Discrete Lengths - This option allows you to decode only those codes containing two selected lengths. For example, if you select I 2 of 5 Two Discrete Lengths, then scan 0, 2, 1, 4, the only I 2 of 5 symbols decoded are those containing 2 or 14 characters. Numeric bar codes begin on page 5-101. If you make an error, or wish to change your selection, scan CANCEL on page 5-103.

Symbol Technologies P470 — Set Lengths for Interleaved 2 of 5 diagram (page 127)
Afb. 115 · Set Lengths for Interleaved 2 of 5

I 2 of 5 - TWO DISCRETE LENGTHS

Parameter Menus

Page 128 of the Symbol Technologies P470 user manual — Set Lengths for Interleaved 2 of 5 (Continued)
Pagina 128 · klik om te vergroten
Pagina 128

Set Lengths for Interleaved 2 of 5 (Continued)

Length Within Range - This option allows you to decode a code type within a specified range. For example to decode I 2 of 5 symbols containing between 4 and 12 characters, first scan I 2 of 5 Length Within Range. Then scan 0, 4, 1 and 2 (single digit numbers must always be preceded by a leading zero). Numeric bar codes begin on page 5-101. If you make an error, or wish to change your selection, scan CANCEL on page 5-103.

Symbol Technologies P470 — Set Lengths for Interleaved 2 of 5 (Continued) diagram (page 128)
Afb. 116 · Set Lengths for Interleaved 2 of 5 (Continued)

I 2 of 5 - LENGTH WITHIN RANGE

Any Length - Scanning this option allows you to decode I 2 of 5 symbols containing any number of characters.

Symbol Technologies P470 — Set Lengths for Interleaved 2 of 5 (Continued) diagram (page 128)
Afb. 117 · Set Lengths for Interleaved 2 of 5 (Continued)

I 2 of 5 - ANY LENGTH

Page 129 of the Symbol Technologies P470 user manual — OPCC CHECK DIGIT
Pagina 129 · klik om te vergroten
Pagina 129

I 2 of 5 Check Digit Verification

When enabled, this parameter checks the integrity of an I 2 of 5 symbol to ensure it complies with a specified algorithm, either USS (Uniform Symbology Specification), or OPCC (Optical Product Code Council).

Symbol Technologies P470 — I 2 of 5 Check Digit Verification diagram (page 129)
Afb. 118 · I 2 of 5 Check Digit Verification

*DISABLE

Symbol Technologies P470 — *DISABLE diagram (page 129)
Afb. 119

USS CHECK DIGIT

Symbol Technologies P470 — USS CHECK DIGIT diagram (page 129)
Afb. 120

OPCC CHECK DIGIT

Parameter Menus

Page 130 of the Symbol Technologies P470 user manual — (ENABLE)
Pagina 130 · klik om te vergroten
Pagina 130

Transmit I 2 of 5 Check Digit

Scan the appropriate bar code below to transmit the data with or without the check digit.

Symbol Technologies P470 — Transmit I 2 of 5 Check Digit diagram (page 130)
Afb. 121 · Transmit I 2 of 5 Check Digit

TRANSMIT I 2 of 5 CHECK DIGIT

(ENABLE)

Symbol Technologies P470 — (ENABLE) diagram (page 130)
Afb. 122

*DO NOT TRANSMIT I 2 of 5 CHECK DIGIT (DISABLE)

Page 131 of the Symbol Technologies P470 user manual — (ENABLE)
Pagina 131 · klik om te vergroten
Pagina 131

Convert I 2 of 5 to EAN-13

This parameter converts a 14 character I 2 of 5 code into EAN-13, and transmits to the host as EAN-13. In order to accomplish this, the I 2 of 5 code must be enabled, one length must be set to 14, and the code must have a leading zero and a valid EAN-13 check digit.

Symbol Technologies P470 — Convert I 2 of 5 to EAN-13 diagram (page 131)
Afb. 123 · Convert I 2 of 5 to EAN-13

CONVERT I 2 of 5 to EAN-13

(ENABLE)

Symbol Technologies P470 — (ENABLE) diagram (page 131)
Afb. 124

*DO NOT CONVERT I 2 of 5 to EAN-13 (DISABLE)

Parameter Menus

Page 132 of the Symbol Technologies P470 user manual — ENABLE DISCRETE 2 OF 5
Pagina 132 · klik om te vergroten
Pagina 132

Enable/Disable Discrete 2 of 5

Scan the appropriate bar code below to enable or disable Discrete 2 of 5.

ENABLE DISCRETE 2 OF 5

*DISABLE DISCRETE 2 OF 5

Page 133 of the Symbol Technologies P470 user manual — Set Lengths for Discrete 2 of 5
Pagina 133 · klik om te vergroten
Pagina 133

Set Lengths for Discrete 2 of 5

Lengths for D 2 of 5 may be set for any length, one or two discrete lengths, or lengths within a specific range. The length of a code refers to the number of characters (i.e., human readable characters) the code contains, and includes check digits.

One Discrete Length - This option allows you to decode only those codes containing a selected length. For example, if you select D 2 of 5 One Discrete Length, then scan 1, 4, the only D 2 of 5 symbols decoded are those containing 14 characters. Numeric bar codes begin on page 5-101. If you make an error, or wish to change your selection, scan CANCEL on page 5-103.

Symbol Technologies P470 — Set Lengths for Discrete 2 of 5 diagram (page 133)
Afb. 125 · Set Lengths for Discrete 2 of 5

D 2 of 5 - ONE DISCRETE LENGTH

Two Discrete Lengths - This option allows you to decode only those codes containing two selected lengths. For example, if you select D 2 of 5 Two Discrete Lengths, then scan 0, 2, 1, 4, the only D 2 of 5 symbols decoded are those containing 2 or 14 characters. Numeric bar codes begin on page 5-101. If you make an error, or wish to change your selection, CANCEL on page 5-103.

Symbol Technologies P470 — Set Lengths for Discrete 2 of 5 diagram (page 133)
Afb. 126 · Set Lengths for Discrete 2 of 5

D 2 of 5 - TWO DISCRETE LENGTHS

Parameter Menus

Page 134 of the Symbol Technologies P470 user manual — Set Lengths for Discrete 2 of 5 (Continued)
Pagina 134 · klik om te vergroten
Pagina 134

Set Lengths for Discrete 2 of 5 (Continued)

Length Within Range - This option allows you to decode a code type within a specified range. For example to decode D 2 of 5 symbols containing between 4 and 12 characters, first scan D 2 of 5 Length Within Range. Then scan 0, 4, 1 and 2 (single digit numbers must always be preceded by a leading zero). Numeric bar codes begin on page 5-101. If you make an error, or wish to change your selection, scan CANCEL on page 5- 103.

Symbol Technologies P470 — Set Lengths for Discrete 2 of 5 (Continued) diagram (page 134)
Afb. 127 · Set Lengths for Discrete 2 of 5 (Continued)

D 2 of 5 - LENGTH WITHIN RANGE

Any Length - Scanning this option allows you to decode D 2 of 5 symbols containing any number of characters.

Symbol Technologies P470 — Set Lengths for Discrete 2 of 5 (Continued) diagram (page 134)
Afb. 128 · Set Lengths for Discrete 2 of 5 (Continued)

D 2 of 5 - ANY LENGTH

Page 135 of the Symbol Technologies P470 user manual — *DISABLE CODABAR
Pagina 135 · klik om te vergroten
Pagina 135

Enable/Disable Codabar

Scan the appropriate bar code below to enable or disable Codabar.

Symbol Technologies P470 — Enable/Disable Codabar diagram (page 135)
Afb. 129 · Enable/Disable Codabar

ENABLE CODABAR

Symbol Technologies P470 — ENABLE CODABAR diagram (page 135)
Afb. 130

*DISABLE CODABAR

Parameter Menus

Page 136 of the Symbol Technologies P470 user manual — CODABAR - TWO DISCRETE LENGTHS
Pagina 136 · klik om te vergroten
Pagina 136

Set Lengths for Codabar

Lengths for Codabar may be set for any length, one or two discrete lengths, or lengths within a specific range. The length of a code refers to the number of characters (i.e., human readable characters) the code contains. It also includes any start or stop characters.

One Discrete Length - This option allows you to decode only those codes containing a selected length. For example, if you select Codabar One Discrete Length, then scan 1, 4, the only Codabar symbols decoded are those containing 14 characters. Numeric bar codes begin on page 5-101. If you make an error, or wish to change your selection, scan CANCEL on page 5-103.

Symbol Technologies P470 — Set Lengths for Codabar diagram (page 136)
Afb. 131 · Set Lengths for Codabar

CODABAR - ONE DISCRETE LENGTH

Two Discrete Lengths - This option allows you to decode only those codes containing two selected lengths. For example, if you select Codabar Two Discrete Lengths, then scan 0, 2, 1, 4, the only Codabar symbols decoded are those containing 2 or 14 characters. Numeric bar codes begin on page 5-101. If you make an error, or wish to change your selection, scan CANCEL on page 5-103.

Symbol Technologies P470 — CODABAR - ONE DISCRETE LENGTH diagram (page 136)
Afb. 132

CODABAR - TWO DISCRETE LENGTHS

Page 137 of the Symbol Technologies P470 user manual — CODABAR - ANY LENGTH
Pagina 137 · klik om te vergroten
Pagina 137

Set Lengths for Codabar (Continued)

Length Within Range - This option allows you to decode a code type within a specified range. For example to decode Codabar symbols containing between 4 and 12 characters, first scan Codabar Length Within Range. Then scan 0, 4, 1 and 2 (single digit numbers must always be preceded by a leading zero). Numeric bar codes begin on page 5-101. If you make an error, or wish to change your selection, scan CANCEL on page 5- 103.

Symbol Technologies P470 — Set Lengths for Codabar (Continued) diagram (page 137)
Afb. 133 · Set Lengths for Codabar (Continued)

CODABAR - LENGTH WITHIN RANGE

Any Length - Scanning this option allows you to decode Codabar symbols containing any number of characters.

Symbol Technologies P470 — CODABAR - LENGTH WITHIN RANGE diagram (page 137)
Afb. 134

CODABAR - ANY LENGTH

Parameter Menus

Page 138 of the Symbol Technologies P470 user manual — *DISABLE CLSI EDITING
Pagina 138 · klik om te vergroten
Pagina 138

CLSI Editing

If enabled, this parameter strips the start and stop characters and inserts a space after the first, fifth, and tenth characters of a 14-character Codabar symbol.

Symbol Technologies P470 — CLSI Editing diagram (page 138)
Afb. 135 · CLSI Editing

ENABLE CLSI EDITING

Symbol Technologies P470 — ENABLE CLSI EDITING diagram (page 138)
Afb. 136

*DISABLE CLSI EDITING

Page 139 of the Symbol Technologies P470 user manual — *DISABLE NOTIS EDITING
Pagina 139 · klik om te vergroten
Pagina 139

NOTIS Editing

If enabled, this parameter strips the start and stop characters from a decoded Codabar symbol.

Symbol Technologies P470 — NOTIS Editing diagram (page 139)
Afb. 137 · NOTIS Editing

ENABLE NOTIS EDITING

Symbol Technologies P470 — ENABLE NOTIS EDITING diagram (page 139)
Afb. 138

*DISABLE NOTIS EDITING

Parameter Menus

Page 140 of the Symbol Technologies P470 user manual — *DISABLE MSI PLESSEY
Pagina 140 · klik om te vergroten
Pagina 140

Enable/Disable MSI Plessey

Scan the appropriate bar code below to enable or disable MSI Plessey.

Symbol Technologies P470 — Enable/Disable MSI Plessey diagram (page 140)
Afb. 139 · Enable/Disable MSI Plessey

ENABLE MSI PLESSEY

Symbol Technologies P470 — ENABLE MSI PLESSEY diagram (page 140)
Afb. 140

*DISABLE MSI PLESSEY

Page 141 of the Symbol Technologies P470 user manual — MSI PLESSEY - TWO DISCRETE LENGTHS
Pagina 141 · klik om te vergroten
Pagina 141

Set Lengths for MSI Plessey

Lengths for MSI Plessey may be set for any length, one or two discrete lengths, or lengths within a specific range. The length of a code refers to the number of characters (i.e., human readable characters) the code contains, and includes check digits.

One Discrete Length - This option allows you to decode only those codes containing a selected length. For example, if you select MSI Plessey One Discrete Length, then scan 1, 4, the only MSI Plessey symbols decoded are those containing 14 characters. Numeric bar codes begin on page 5-101. If you make an error, or wish to change your selection, scan CANCEL on page 5-103.

Symbol Technologies P470 — Set Lengths for MSI Plessey diagram (page 141)
Afb. 141 · Set Lengths for MSI Plessey

MSI PLESSEY - ONE DISCRETE LENGTH

Two Discrete Lengths - This option allows you to decode only those codes containing two selected lengths. For example, if you select MSI Plessey Two Discrete Lengths, then scan 0, 2, 1, 4, the only MSI Plessey symbols decoded are those containing 2 or 14 characters. Numeric bar codes begin on page 5-101. If you make an error, or wish to change your selection, scan CANCEL on page 5-103.

Symbol Technologies P470 — MSI PLESSEY - ONE DISCRETE LENGTH diagram (page 141)
Afb. 142

MSI PLESSEY - TWO DISCRETE LENGTHS

Parameter Menus

Page 142 of the Symbol Technologies P470 user manual — *MSI PLESSEY - ANY LENGTH
Pagina 142 · klik om te vergroten
Pagina 142

Set Lengths for MSI Plessey (Continued)

Length Within Range - This option allows you to decode a code type within a specified range. For example to decode MSI Plessey symbols containing between 4 and 12 characters, first scan MSI Plessey Length Within Range. Then scan 0, 4, 1 and 2 (single digit numbers must always be preceded by a leading zero). Numeric bar codes begin on page 5-101. If you make an error, or wish to change your selection, scan CANCEL on page 5-103.

Symbol Technologies P470 — Set Lengths for MSI Plessey (Continued) diagram (page 142)
Afb. 143 · Set Lengths for MSI Plessey (Continued)

MSI PLESSEY - LENGTH WITHIN RANGE

Any Length - Scanning this option allows you to decode MSI Plessey symbols containing any number of characters.

codes.

Symbol Technologies P470 — MSI PLESSEY - LENGTH WITHIN RANGE diagram (page 142)
Afb. 144

*MSI PLESSEY - ANY LENGTH

Page 143 of the Symbol Technologies P470 user manual — TWO MSI PLESSEY CHECK DIGITS
Pagina 143 · klik om te vergroten
Pagina 143

MSI Plessey Check Digits

These check digits at the end of the bar code verify the integrity of the data. At least one check digit is always required. Check digits are not automatically transmitted with the data.

Symbol Technologies P470 — MSI Plessey Check Digits diagram (page 143)
Afb. 145 · MSI Plessey Check Digits

*ONE MSI PLESSEY CHECK DIGIT

Symbol Technologies P470 — *ONE MSI PLESSEY CHECK DIGIT diagram (page 143)
Afb. 146

TWO MSI PLESSEY CHECK DIGITS

Parameter Menus

Page 144 of the Symbol Technologies P470 user manual — *DO NOT TRANSMIT MSI PLESSEY CHECK DIGIT (DISABLE)
Pagina 144 · klik om te vergroten
Pagina 144

Transmit MSI Plessey Check Digit

Scan the appropriate bar code below to transmit the data with or without the check digit.

Symbol Technologies P470 — Transmit MSI Plessey Check Digit diagram (page 144)
Afb. 147 · Transmit MSI Plessey Check Digit

TRANSMIT MSI PLESSEY CHECK DIGIT

(ENABLE)

Symbol Technologies P470 — TRANSMIT MSI PLESSEY CHECK DIGIT diagram (page 144)
Afb. 148

*DO NOT TRANSMIT MSI PLESSEY CHECK DIGIT (DISABLE)

Page 145 of the Symbol Technologies P470 user manual — *MOD 10/MOD 10
Pagina 145 · klik om te vergroten
Pagina 145

MSI Plessey Check Digit Algorithm

When the two MSI Plessey check digits option is selected, an additional verification is required to ensure integrity. Either of the two following algorithms may be selected.

Symbol Technologies P470 — MSI Plessey Check Digit Algorithm diagram (page 145)
Afb. 149 · MSI Plessey Check Digit Algorithm

MOD 10/MOD 11

Symbol Technologies P470 — MOD 10/MOD 11 diagram (page 145)
Afb. 150

*MOD 10/MOD 10

Parameter Menus

Page 146 of the Symbol Technologies P470 user manual — K = UCC/EAN-128
Pagina 146 · klik om te vergroten
Pagina 146

Transmit Code ID Character

A code ID character identifies the code type of a scanned bar code. This may be useful when the scanner is decoding more than one code type. The code ID character precedes the decoded symbol.

The user may select no code ID character, a Symbol Code ID character, or an AIM Code ID character. The Symbol Code ID characters are listed below; see Appendix A, Bar Code Information for AIM Identifiers.

Symbol Code ID Characters

A = UPC-A, UPC-E, EAN-8, EAN-13

B = Code 39

D = Code 128

E = Code 93

F = Interleaved 2 of 5

G = Discrete 2 of 5, or Discrete 2 of 5 IATA

J = MSI Plessey

K = UCC/EAN-128

L = Bookland EAN

M = Trioptic Code 39

N = Coupon Code

C = Codabar

Page 147 of the Symbol Technologies P470 user manual — *NONE
Pagina 147 · klik om te vergroten
Pagina 147

Transmit Code ID Character (Continued)

Symbol Technologies P470 — Transmit Code ID Character (Continued) diagram (page 147)
Afb. 151 · Transmit Code ID Character (Continued)

SYMBOL CODE ID CHARACTER

Symbol Technologies P470 — SYMBOL CODE ID CHARACTER diagram (page 147)
Afb. 152

AIM CODE ID CHARACTER

Symbol Technologies P470 — AIM CODE ID CHARACTER diagram (page 147)
Afb. 153

*NONE

Parameter Menus

Page 148 of the Symbol Technologies P470 user manual — PAUSE DURATION
Pagina 148 · klik om te vergroten
Pagina 148

Pause Duration

This parameter allows a pause to be inserted at any point in the data transmission. Pauses are set by scanning the bar code below followed by a two digit number (i.e. two bar codes), and are measured in 1/10 second intervals. For example, scanning bar codes “0” and “1” inserts a 1/10 second pause; “0” and “5” gives you a 1/2 second delay. Numeric bar codes begin on page 5-101. If you make an error, or wish to change your selection, scan CANCEL on page 5-103.

Symbol Technologies P470 — Pause Duration diagram (page 148)
Afb. 154 · Pause Duration

PAUSE DURATION

Page 149 of the Symbol Technologies P470 user manual — BAUD RATE 2400
Pagina 149 · klik om te vergroten
Pagina 149

RS-232C Parameters

Baud Rate

Baud rate is the number of bits of data transmitted per second. The scanner's baud rate setting should match the data rate setting of the host device. If not, data may not reach the host device or may reach it in distorted form.

Symbol Technologies P470 — RS-232C Parameters diagram (page 149)
Afb. 155 · RS-232C Parameters

BAUD RATE 600

Symbol Technologies P470 — BAUD RATE 600 diagram (page 149)
Afb. 156

BAUD RATE 1200

Symbol Technologies P470 — BAUD RATE 1200 diagram (page 149)
Afb. 157

BAUD RATE 2400

Parameter Menus

Page 150 of the Symbol Technologies P470 user manual — BAUD RATE 38,400
Pagina 150 · klik om te vergroten
Pagina 150

Baud Rate (Continued)

Symbol Technologies P470 — Baud Rate (Continued) diagram (page 150)
Afb. 158 · Baud Rate (Continued)

BAUD RATE 4800

Symbol Technologies P470 — BAUD RATE 4800 diagram (page 150)
Afb. 159

*BAUD RATE 9600

Symbol Technologies P470 — *BAUD RATE 9600 diagram (page 150)
Afb. 160

BAUD RATE 19,200

Symbol Technologies P470 — BAUD RATE 19,200 diagram (page 150)
Afb. 161

BAUD RATE 38,400

Page 151 of the Symbol Technologies P470 user manual — EVEN
Pagina 151 · klik om te vergroten
Pagina 151

Parity

A parity check bit is the most significant bit of each ASCII coded character. Select the parity type according to host device requirements.

If you select ODD parity, the parity bit has a value 0 or 1, based on data, to ensure that an odd number of 1 bits are contained in the coded character.

Symbol Technologies P470 — Parity diagram (page 151)
Afb. 162 · Parity

ODD

If you select EVEN parity, the parity bit has a value 0 or 1, based on data, to ensure that an even number of 1 bits are contained in the coded character.

Symbol Technologies P470 — ODD diagram (page 151)
Afb. 163

EVEN

Parameter Menus

Page 152 of the Symbol Technologies P470 user manual — *NONE
Pagina 152 · klik om te vergroten
Pagina 152

Parity (Continued)

Select MARK parity and the parity bit is always 1.

Symbol Technologies P470 — Parity (Continued) diagram (page 152)
Afb. 164 · Parity (Continued)

MARK

Select SPACE parity and the parity bit is always 0.

Symbol Technologies P470 — MARK diagram (page 152)
Afb. 165

SPACE

If no parity is required, select NONE.

Symbol Technologies P470 — SPACE diagram (page 152)
Afb. 166

*NONE

Page 153 of the Symbol Technologies P470 user manual — *DO NOT CHECK FOR RECEIVED ERRORS
Pagina 153 · klik om te vergroten
Pagina 153

Check Receive Errors

Select whether or not the parity, framing, and overrun of received characters are checked. The type of parity used is selectable through the PARITY parameter.

Symbol Technologies P470 — Check Receive Errors diagram (page 153)
Afb. 167 · Check Receive Errors

CHECK FOR RECEIVED ERRORS

Symbol Technologies P470 — CHECK FOR RECEIVED ERRORS diagram (page 153)
Afb. 168

*DO NOT CHECK FOR RECEIVED ERRORS

Parameter Menus

Page 154 of the Symbol Technologies P470 user manual — Hardware Handshaking
Pagina 154 · klik om te vergroten
Pagina 154

Hardware Handshaking

The data interface consists of an RS-232C port. The port has been designed to operate either with or without the hardware handshaking lines, RTS, Request to Send, and CTS, Clear to Send.

If Standard RTS/CTS handshaking is selected, scan data is transmitted according to the following sequence:

  • The scanner reads the CTS line for activity. If CTS is asserted, the scanner waits up to two seconds for the host to negate the CTS line. If, after two seconds (default), the CTS line is still asserted, the scanner sounds a transmit error and any scanned data is lost.
  • When the CTS line is negated, the scanner asserts the RTS line and waits up to two seconds for the host to assert CTS. When the host asserts CTS, data is transmitted. If, after two seconds (default), the CTS line is not asserted, the scanner sounds a transmit error and discards the data.
  • When data transmission is complete, the scanner negates RTS 10 msec after sending the last character.
  • The host should respond by negating CTS. The scanner checks for a negated CTS upon the next transmission of data.

During the transmission of data, the CTS line should be asserted. If CTS is deasserted for more than 50 ms between characters, the transmission is aborted, the scanner sounds a transmission error, and the data is discarded.

If the above communications sequence fails, the scanner issues an error indication. In this case, the data is lost and must be rescanned.

If Hardware Handshaking and Software Handshaking are both enabled, Hardware Handshaking will take precedence.

is an 8 ms delay for the information to travel between the host and the scanner. If this setup is necessary, scan the Intercharacter Delay bar code on page 5-93 and set the delay for 10 ms or more.

Page 155 of the Symbol Technologies P470 user manual — RTS/CTS OPTION 1
Pagina 155 · klik om te vergroten
Pagina 155

Hardware Handshaking (Continued)

Scan the bar code below if no Hardware Handshaking is desired.

Symbol Technologies P470 — Hardware Handshaking (Continued) diagram (page 155)
Afb. 169 · Hardware Handshaking (Continued)

*NONE

Scan the bar code below to select Standard RTS/CTS Hardware Handshaking.

Symbol Technologies P470 — *NONE diagram (page 155)
Afb. 170

STANDARD RTS/CTS

When RTS/CTS Option 1 is selected, the cradle asserts RTS before transmitting and ignores the state of CTS. The scanner deasserts RTS when the transmission is complete.

Symbol Technologies P470 — STANDARD RTS/CTS diagram (page 155)
Afb. 171

RTS/CTS OPTION 1

Parameter Menus

Page 156 of the Symbol Technologies P470 user manual — *NONE
Pagina 156 · klik om te vergroten
Pagina 156

Hardware Handshaking (Continued)

When Option 2 is selected, RTS is always high or low (user-programmed logic level). However, the scanner waits for CTS to be asserted before transmitting data. If CTS is not asserted within two seconds (default), the scanner issues an error indication and discards the data.

Symbol Technologies P470 — Hardware Handshaking (Continued) diagram (page 156)
Afb. 172 · Hardware Handshaking (Continued)

RTS/CTS OPTION 2

When Option 3 is selected, the scanner asserts RTS prior to any data transmission, regardless of the state of CTS. The scanner waits up to two seconds (default) for CTS to be asserted. If CTS is not asserted during this time, the scanner issues an error indication and discards the data. The scanner deasserts RTS when transmission is complete.

Symbol Technologies P470 — RTS/CTS OPTION 2 diagram (page 156)
Afb. 173

RTS/CTS OPTION 3

Software Handshaking

This parameter offers control of the data transmission process in addition to, or instead of, that offered by hardware handshaking. There are five options.

If Software Handshaking and Hardware Handshaking are both enabled, Hardware Handshaking takes precedence.

None

When this option is selected, data is transmitted immediately.

Symbol Technologies P470 — None diagram (page 156)
Afb. 174 · None

*NONE

Page 157 of the Symbol Technologies P470 user manual — ENQ
Pagina 157 · klik om te vergroten
Pagina 157

Software Handshaking (Continued)

ACK/NAK

When this option is selected, after transmitting data, the cradle expects either an ACK, Acknowledge, or NAK, Negative Acknowledge, response from the host. Whenever a NAK is received, the cradle transmits the same data again and waits for either an ACK or NAK. After three unsuccessful attempts to send data when NAKs are received, the cradle issues an error indication and discards the data.

The cradle waits up to the programmable Host Serial Response Time-out to receive an ACK or NAK. If the cradle does not get a response in this time, it issues an error indication and discards the data. There are no retries when a time-out occurs.

Symbol Technologies P470 — ACK/NAK diagram (page 157)
Afb. 175

ACK/NAK

ENQ

When this option is selected, the cradle waits for an ENQ, Enquiry, character from the host before transmitting data. If an ENQ is not received within two seconds, the cradle issues an error indication and discards the data. The host must transmit an ENQ character at least every two seconds to prevent transmission errors.

Symbol Technologies P470 — ACK/NAK diagram (page 157)
Afb. 176

ENQ

ACK/NAK with ENQ

This combines the two previous options.

Symbol Technologies P470 — ENQ diagram (page 157)
Afb. 177

Parameter Menus · ACK/NAK with ENQ

Page 158 of the Symbol Technologies P470 user manual — HOST SERIAL RESPONSE TIME-OUT
Pagina 158 · klik om te vergroten
Pagina 158

Software Handshaking (Continued)

XON/XOFF

An XOFF, Transmit Off, character turns the scanner transmission off until the scanner receives an XON, Transmit On, character. There are two situations for XON/XOFF:

  • XOFF is received before the scanner has data to send. When the scanner has data to send, it then waits for an XON character before transmission. The scanner waits up to two seconds to receive the XON. If the XON is not received within this time, the scanner issues an error indication and discards the data.
  • XOFF is received during a transmission. Data transmission then stops after sending the current byte. When the scanner receives an XON character, it sends the rest of the data message. The scanner waits indefinitely for the XON.
Symbol Technologies P470 — XON/XOFF diagram (page 158)
Afb. 178

XON/XOFF

Host Serial Response Time-out

This parameter specifies how long the scanner waits for an ACK, NAK or CTS before determining that a transmission error has occurred. This only applies when in one of the ACK/NAK Software Handshaking modes, or RTS/CTS Hardware Handshaking option.

The delay period can range from 0.0 to 9.9 seconds in 0.1 second increments. After scanning the bar code below, scan two numeric bar codes beginning on page 5-101. If you make an error, or wish to change your selection, scan CANCEL on page 5-103.

Symbol Technologies P470 — XON/XOFF diagram (page 158)
Afb. 179

HOST SERIAL RESPONSE TIME-OUT

Page 159 of the Symbol Technologies P470 user manual — HOST: HIGH RTS
Pagina 159 · klik om te vergroten
Pagina 159

RTS Line State

Scan the appropriate bar code below to set the idle state of the Serial Host RTS line. Choose LOW RTS line state or HIGH RTS line state.

Symbol Technologies P470 — RTS Line State diagram (page 159)
Afb. 180 · RTS Line State

*HOST: LOW RTS

Symbol Technologies P470 — *HOST: LOW RTS diagram (page 159)
Afb. 181

HOST: HIGH RTS

Parameter Menus

Page 160 of the Symbol Technologies P470 user manual — *8-BIT
Pagina 160 · klik om te vergroten
Pagina 160

Stop Bit Select

The stop bit(s) at the end of each transmitted character marks the end of transmission of one character and prepares the receiving device for the next character in the serial data stream. The number of stop bits (one or two) selected depends on the number the receiving terminal is programmed to accommodate. Set the number of stop bits to match host device requirements.

Symbol Technologies P470 — Stop Bit Select diagram (page 160)
Afb. 182 · Stop Bit Select

*1 STOP BIT

Symbol Technologies P470 — *1 STOP BIT diagram (page 160)
Afb. 183

2 STOP BITS

ASCII Format

This parameter allows the cradle to interface with devices requiring a 7-bit or 8-bit ASCII protocol.

Symbol Technologies P470 — 2 STOP BITS diagram (page 160)
Afb. 184

7-BIT

Symbol Technologies P470 — 7-BIT diagram (page 160)
Afb. 185

*8-BIT

Page 161 of the Symbol Technologies P470 user manual — BAUD RATE 600
Pagina 161 · klik om te vergroten
Pagina 161

Intercharacter Delay

Select the intercharacter delay option matching host requirements. The intercharacter delay gives the host system time to service its receiver and perform other tasks between characters. The delay period can range from no delay to 99 ms in 1 ms increments (if you are using a cradle and RTS/CTS handshaking, the delay period can range from 5 ms to 99 ms). After scanning the bar code below, scan two bar codes beginning on page 5-101 to set the desired time-out. If you make an error, or wish to change your selection, scan CANCEL on page 5-103.

Symbol Technologies P470 — Intercharacter Delay diagram (page 161)
Afb. 186 · Intercharacter Delay

INTERCHARACTER DELAY

MCL-Net Parameters

MCL-Net Baud Rate

Baud rate is the number of bits of data transmitted per second. Scan the appropriate bar code below to set the MCL-Net baud rate. The default baud rate is 38400.

Symbol Technologies P470 — INTERCHARACTER DELAY diagram (page 161)
Afb. 187

BAUD RATE 600

Parameter Menus

Page 162 of the Symbol Technologies P470 user manual — BAUD RATE 1200
Pagina 162 · klik om te vergroten
Pagina 162

BAUD RATE 1200

BAUD RATE 2400

Page 163 of the Symbol Technologies P470 user manual — BAUD RATE 4800
Pagina 163 · klik om te vergroten
Pagina 163

MCL-Net Baud Rate (Continued)

BAUD RATE 4800

BAUD RATE 9600

BAUD RATE 19200

*BAUD RATE 38400

Parameter Menus

Page 164 of the Symbol Technologies P470 user manual — *MCL-NET HEX ADDRESSING DISABLED
Pagina 164 · klik om te vergroten
Pagina 164

MCL-Net Hex Addressing Mode

Scan the appropriate bar code below to set the MCL-Net Hex addressing mode. The default mode is Disabled.

*MCL-NET HEX ADDRESSING DISABLED

MCL-NET HEX ADDRESSING ENABLED

Page 165 of the Symbol Technologies P470 user manual — MCL-NET FRAME TIMEOUT
Pagina 165 · klik om te vergroten
Pagina 165

Scanner Address

Scan the following barcode, followed by 3 digits from the numeric barcode section (starting on page 5-101), to set the address of the scanner (scanner ID).

The number of scanner addresses (scanner ID’s) varies with the selected communication protocol.

  • RS-232/Synapse range from 001 to 254
  • MCL Link Lite (MCL Net) range from 001 to 002
  • MCL Link (MCL Net) range from 001 to 254
Symbol Technologies P470 — Scanner Address diagram (page 165)
Afb. 188 · Scanner Address

SCANNER ADDRESS

MCL-Net Transmit Retries

Scan the following barcode, followed by 2 digits from the numeric barcode section (starting on page 5-101), to define the number of retries in the range 1 to 10.

Symbol Technologies P470 — SCANNER ADDRESS diagram (page 165)
Afb. 189

MCL-NET RETRIES

MCL-Net Frame Timeout

Scan the following barcode, followed by 2 digits from the numeric barcode section (starting on page 5-101), to define the amount of time to wait for an ACK or NAK from the host before retransmitting. The timeout is in 100 ms increments in the range 100 ms to 3000 ms.

Symbol Technologies P470 — MCL-NET RETRIES diagram (page 165)
Afb. 190

MCL-NET FRAME TIMEOUT

Parameter Menus

Page 166 of the Symbol Technologies P470 user manual — Scanner Decode Beep Type
Pagina 166 · klik om te vergroten
Pagina 166
Symbol Technologies P470 — Scanner Decode Beep Type diagram (page 166)
Afb. 191 · Scanner Decode Beep Type

Select the type of beep for the scanner. This parameter is useful when two or more systems are installed in proximity of each other. Unique patterns can be set up to distinguish each system’s receipt of bar code data.

Page 167 of the Symbol Technologies P470 user manual — Option 2: Trigger Release to Scan
Pagina 167 · klik om te vergroten
Pagina 167

Long Range Scanning Bar Codes

The P370 ALR (Long Range) scanner has an aiming feature which allows the positioning of the laser beam when scanning bar codes. Aiming mode and Aiming duration can be set using the bar codes below. You cannot program this feature into the standard range P370 scanner.

Aim Mode

There are two Aiming options supported by the Phaser ALR cordless scanner, trigger pull to scan (default) and trigger release to scan.

Option 1: Trigger Pull to Scan (Default)

When you pull the trigger, the aim dot will be active for a user-selectable duration of time. After this time, the aiming dot automatically turns into a standard laser scanning beam for a full decode session. After the aiming dot turns into a scanning beam, the laser will stay on until the user-selectable laser-on timeout occurs, a decode occurs, or the trigger is released. If the trigger is released during the aim mode, the laser shut off and no decode session occurs.

³ 2 0 5 1 B 0 0 *Trigger Pull to Scan (Default)

Option 2: Trigger Release to Scan

When you pull the trigger, the aiming dot will appear. The aiming dot remains present while the trigger is pulled or until a 60 second timeout occurs. When the trigger is released, the aiming dot turns into a standard laser scanning beam for a full decode session. The laser stays on until a decode occurs or until the user-selectable laser-on timeout occurs. If the trigger is pulled again while in a decode session, the scanner returns to its aiming mode.

Trigger Release to Scan

Parameter Menus

Page 168 of the Symbol Technologies P470 user manual — Aim Duration
Pagina 168 · klik om te vergroten
Pagina 168

Aim Duration

When the scanner is in Trigger Pull to Scan mode (default mode), Aim Duration sets the amount of time the aiming dot is seen before turning into a scanning beam. This parameter has no affect when the scanner is in the Trigger Release to Scan mode.

The Aim Duration is programmable in 0.1 second increments, from 0 to 9.9 seconds. If set to 0, no aiming pattern appears before a decode session. The default value is 0.8 seconds.

To set an aim duration, scan the barcode below. Then, scan two numeric barcodes, beginning on page 5-101, that correspond to the desired aim duration. Durations less than 1.0 second must have a leading zero. For example, to set an aim duration of 0.5 seconds, scan the barcode below, followed by the '0' and the '5' barcodes. If you make an error or wish to change your selection, scan the CANCEL barcode on page 5-103.

Aim Duration

Page 169 of the Symbol Technologies P470 user manual — Numeric Bar Codes
Pagina 169 · klik om te vergroten
Pagina 169

Numeric Bar Codes

For parameters requiring specific numeric values, scan the appropriately numbered bar code(s).

Parameter Menus

Page 170 of the Symbol Technologies P470 user manual — Numeric Bar Codes (Continued)
Pagina 170 · klik om te vergroten
Pagina 170

Numeric Bar Codes (Continued)

Page 171 of the Symbol Technologies P470 user manual — CANCEL
Pagina 171 · klik om te vergroten
Pagina 171

Numeric Bar Codes (Continued)

Cancel

If you make an error, or wish to change your selection, scan the bar code below.

CANCEL

Parameter Menus

Page 172 of the Symbol Technologies P470 user manual — Cancel
Pagina 172 · klik om te vergroten
Pagina 172
Page 172 of the Symbol Technologies P470 user manual — Cancel
Page 173 of the Symbol Technologies P470 user manual — A-1
Pagina 173 · klik om te vergroten
Pagina 173

Appendix A Bar Code Information

UCC/EAN-128

UCC/EAN-128 is a convention for printing data fields with standard Code 128 bar code symbols. UCC/EAN-128 symbols are distinguished by a leading FNC 1 character as the first or second character in the symbol. Other FNC 1 characters are used to delineate fields.

When EAN-128 symbols are read, they are transmitted after special formatting strips off the leading FNC 1 character and replaces other FNC 1 characters with the ASCII 29 GS control character.

When AIM symbology identifiers are transmitted, the modifier character indicates the position of the leading FNC 1 character according to AIM guidelines. For example, ]c1 indicates a UCC/EAN-128 symbol with a leading FNC1 character.

Standard Code 128 bar codes which do not have a leading FNC 1 may still be used, but are not encoded according to the EAN-128 convention. Standard Code 128 and UCC/EAN- 128 may be mixed in an application. The scanner autodiscriminates between these symbols and can enable or disable one or both code types via bar code menus. The following table indicates the behavior of the scanner in each of the four possible parameter settings.

A-1

Page 174 of the Symbol Technologies P470 user manual — A-2
Pagina 174 · klik om te vergroten
Pagina 174

Table A-1. Reading Standard Code128 & UCC/EAN 1 2 8

UCC/EAN-128 Effect and Example

Disable Disable No Code 128 symbols can be read.

Disable Enable Read only symbols with leading FNC 1.

Examples: FNC1ABCDFNC1E will be read as ABCD29E AFNC1BCDFNC1E will be read as ABCD29E FNC1FNC1ABCDFNC1E will be read as ABCD29E ABCDFNC1E can not be read ABCDE can not be read

Enable Disable Read only symbols without leading FNC 1.

Examples: FNC1ABCDFNC1E can not be read AFNC1BCDFNC1E can not be read FNC1FNC1ABCDFNC1E can not be read ABCDFNC1E will be read as ABCD29E ABCDE will be read as ABCDE

Enable Enable Read both types of symbols.

Examples: FNC1ABCDFNC1E will be read as ABCD29E AFNC1BCDFNC1E will be read as ABCD29E FNC1FNC1ABCDFNC1E will be read as ABCD29E ABCDFNC1E will be read as ABCD29E ABCDE will be read as ABCDE

A-2

Standard Code 128

Page 175 of the Symbol Technologies P470 user manual — A-3
Pagina 175 · klik om te vergroten
Pagina 175

AIM Code Identifiers

Each AIM Code Identifier contains the three-character string ]cm where:

] = Flag Character (ASCII 93) c = Code Character (see Table A-2) m = Modifier Character (see Table A-3)

Table A-2. Code Characters

Code Character Code Type

E UPC/EAN

I Interleaved 2 of 5

S D2 of 5, IATA 2 of 5

X Bookland EAN, Code 39 Trioptic, Coupon Code

A-3

Show 7 more labels / short text on this page
Bar Code Information · A Code 39 · C Code 128/EAN-128 · F Codabar · G Code 93 · H Code 11 · M MSI Plessey
Page 176 of the Symbol Technologies P470 user manual — A-4
Pagina 176 · klik om te vergroten
Pagina 176

The modifier character is the sum of the applicable option values based on the following table.

Table A-3. Modifier Characters

Code Type Option Value Option

Code 39 0 No check character or Full ASCII processing.

1 Reader has checked one check character.

3 Reader has checked and stripped check character.

4 Reader has performed Full ASCII character conversion.

5 Reader has performed Full ASCII character conversion and checked one check character.

7 Reader has performed Full ASCII character conversion and checked and stripped check character.

Example: A Full ASCII bar code with check character W, A+I+MI+DW, is transmitted as ]A7AimId where 7 = (3+4).

Trioptic Code 39 0 No option specified at this time. Always transmit 0.

ExampleA Trioptic bar code 412356 is transmitted as ]X0 412356

Code 128 0 Standard data packet, no Function code 1 in first symbol position.

1 Function code 1 in first symbol character position.

2 Function code 1 in second symbol character position.

Example: A Code (EAN) 128 bar code with Function 1 character in the first position, FNC1 Aim Id is transmitted as ]C1AimId

I 2 of 5 0 No check digit processing.

1 Reader has validated check digit.

3 Reader has validated and stripped check digit.

Example: An I 2 of 5 bar code without check digit, 4123, is transmitted as ]I04123

A-4

Page 177 of the Symbol Technologies P470 user manual — A-5
Pagina 177 · klik om te vergroten
Pagina 177

Table A-3. Modifier Characters (Continued)

Code Type Option Value Option

Codabar 0 No check digit processing.

1 Reader has checked check digit.

3 Reader has stripped check digit before transmission.

ExampleA Codabar bar code without check digit, 4123, is transmitted as ]F0 4123

Code 93 0 No options specified at this time. Always transmit 0.

ExampleA Code 93 bar code 012345678905 is transmitted as ]G0 012345678905

MSI Plessey 0 Single check digit checked.

1 Two check digits checked.

2 Single check digit verified and stripped before transmission.

3 Two check digits verified and stripped before transmission.

Example: An MSI Plessey bar code 4123, with a single check digit checked, is transmitted as ]M04123

D 2 of 5 0 No options specified at this time. Always transmit 0.

ExampleA D 2 of 5 bar code 4123, is transmitted as ]S0 4123

UPC/EAN 0 Standard packet in full EAN country code format, which is 13 digits for UPC-A and UPC-E (not including supplemental data).

1 Two-digit supplement data only.

2 Five-digit supplement data only.

4 EAN-8 data packet.

ExampleA UPC-A bar code 012345678905 is transmitted as ]E0 0012345678905

Bookland EAN 0 No options specified at this time. Always transmit 0.

ExampleA Bookland EAN bar code 123456789X is transmitted as ]X0 123456789X

A-5

Bar Code Information

Page 178 of the Symbol Technologies P470 user manual — A-6
Pagina 178 · klik om te vergroten
Pagina 178

According to AIM standards, a UPC with supplemental bar code is transmitted in one of the following formats:

]E0 (UPC chars) (terminator) ]E2 (supplemental) (terminator) or

]E2 (supplemental) (terminator) ]E0 (UPC chars) (terminator)

In the scanner, however, the format is changed to:

]E0 (UPC chars) ]E2 (supplemental)

Therefore, a UPC with two supplemental characters, 01234567890510, is transmitted to the host as a 21-character string, ]E00012345678905]E110.

Table A-4. Symbol Code Identifier Characters

Code Type Symbol Identifier

UPC-A, UPC-E, EAN-13, EAN-8 A

Interleaved 2 of 5 F

Discrete 2 of 5, D 2 of 5 IATA G

UCC/EAN 128 K

Trioptic Code 39 M

A-6

Show 7 more labels / short text on this page
Code 39 B · Codabar C · Code 128 D · Code 93 E · MSI Plessey J · Bookland EAN L · PDF417, MicroPDF417 X
Page 179 of the Symbol Technologies P470 user manual — 1023 $W CTRL W 1047 / /
Pagina 179 · klik om te vergroten
Pagina 179

Table A-5. ASCII Character Set

Code 39 Encode Char.

Code 39 Encode Char

1000 %U CTRL 2 1024 $X CTRL X

1001 $A CTRL A 1025 $Y CTRL Y

1002 $B CTRL B 1026 $Z CTRL Z

1003 $C CTRL C 1027 %A CTRL [

1004 $D CTRL D 1028 %B CTRL \

1005 $E CTRL E 1029 %C CTRL ]

1006 $F CTRL F 1030 %D CTRL 6

1007 $G CTRL G 1031 %E CTRL -

1008 $H CTRL H 1032 Space Space

1009 $I CTRL I 1033 /A !

1010 $J CTRL J 1034 /B ‘

1011 $K CTRL K 1035 /C #

1012 $L CTRL L 1036 /D $

1013 $M CTRL M 1037 /E %

1014 $N CTRL N 1038 /F &

1015 $O CTRL O 1039 /G ‘

1016 $P CTRL P 1040 /H (

1017 $Q CTRL Q 1041 /I )

1018 $R CTRL R 1042 /J *

1019 $S CTRL S 1043 /K +

1020 $T CTRL T 1044 /L ,

1021 $U CTRL U 1045 - -

1022 $V CTRL V 1046 . .

1023 $W CTRL W 1047 / /

A-7

Show 6 more labels / short text on this page
Bar Code Information · ASCII Value · Full ASCII · Keystroke ASCII Value · Full ASCII · Keystroke
Page 180 of the Symbol Technologies P470 user manual — A-8
Pagina 180 · klik om te vergroten
Pagina 180

Table A-5. ASCII Character Set (Continued)

Code 39 Encode Char.

Code 39 Encode Char

1048 0 0 1073 I I

1049 1 1 1074 J J

1050 2 2 1075 K K

1051 3 3 1076 L L

1052 4 4 1077 M M

1053 5 5 1078 N N

1054 6 6 1079 O O

1055 7 7 1080 P P

1056 8 8 1081 Q Q

1057 9 9 1082 R R

1058 /Z : 1083 S S

1059 %F ; 1084 T T

1060 %G < 1085 U U

1061 %H = 1086 V V

1062 %I > 1087 W W

1063 %J ? 1088 X X

1064 %V @ 1089 Y Y

1065 A A 1090 Z Z

1066 B B 1091 %K [

1067 C C 1092 %L \

1068 D D 1093 %M ]

1069 E E 1094 %N ^

1070 F F 1095 %O _

1071 G G 1096 %W ‘

1072 H H 1097 +A a

A-8

Show 5 more labels / short text on this page
ASCII Value · Full ASCII · Keystroke ASCII Value · Full ASCII · Keystroke
Page 181 of the Symbol Technologies P470 user manual — A-9
Pagina 181 · klik om te vergroten
Pagina 181

Table A-5. ASCII Character Set (Continued)

Code 39 Encode Char.

Code 39 Encode Char

1098 +B b 1113 +Q q

1099 +C c 1114 +R r

1100 +D d 1115 +S s

1101 +E e 1116 +T t

1102 +F f 1117 +U u

1103 +G g 1118 +V v

1104 +H h 1119 +W w

1105 +I i 1120 +X x

1106 +J j 1121 +Y y

1107 +K k 1122 +Z z

1108 +L l 1123 %P {

1109 +M m 1124 %Q |

1110 +N n 1125 %R }

1111 +O o 1126 %S ~

1112 +P p 1127 Undefined

A-9

Show 6 more labels / short text on this page
Bar Code Information · ASCII Value · Full ASCII · Keystroke ASCII Value · Full ASCII · Keystroke
Page 182 of the Symbol Technologies P470 user manual — 3001 PA 1 3009 CMD 7 3017 °
Pagina 182 · klik om te vergroten
Pagina 182

Table A-5. ASCII Character Set (Continued)

ALT Keys Keystroke ALT Keys Keystroke ALT Keys Keystroke

2064 ALT 2 2075 ALT K 2086 ALT V

2065 ALT A 2076 ALT L 2087 ALT W

2066 ALT B 2077 ALT M 2088 ALT X

2067 ALT C 2078 ALT N 2089 ALT Y

2068 ALT D 2079 ALT O 2090 ALT Z

2069 ALT E 2080 ALT P 2091 ALT [

2070 ALT F 2081 ALT Q 2092 ALT \

2071 ALT G 2082 ALT R 2093 ALT ]

2072 ALT H 2083 ALT S 2094 ALT 6

2073 ALT I 2084 ALT T 2095 ALT -

2074 ALT J 2085 ALT U

Misc. Key Keystroke Misc. Key Keystroke Misc. Key Keystroke

3001 PA 1 3009 CMD 7 3017 °

3002 PA 2 3010 CMD 8 3018 1/2

3003 CMD 1 3011 CMD 9 3019 ¶

3004 CMD 2 3012 CMD 10 3020 §

3005 CMD 3 3013 ¥ 3021 |

3006 CMD 4 3014 £ 3022 0/00

3007 CMD 5 3015 ¤

3008 CMD 6 3016 ¬

A-10

Page 183 of the Symbol Technologies P470 user manual — A-11
Pagina 183 · klik om te vergroten
Pagina 183

Table A-5. ASCII Character Set (Continued)

PF Keys Keystroke PF Keys Keystroke PF Keys Keystroke

4001 PF 1 4009 PF 9 4017 PF 17

4002 PF 2 4010 PF 10 4018 PF 18

4003 PF 3 4011 PF 11 4019 PF 19

4004 PF 4 4012 PF 12 4020 PF 20

4005 PF 5 4013 PF 13 4021 PF 21

4006 PF 6 4014 PF 14 4022 PF 22

4007 PF 7 4015 PF 15 4023 PF 23

4008 PF 8 4016 PF 16 4024 PF 24

F Keys Keystroke F Keys Keystroke F Keys Keystroke

5001 F 1 5014 F 14 5027 F 27

5002 F 2 5015 F 15 5028 F 28

5003 F 3 5016 F 16 5029 F 29

5004 F 4 5017 F 17 5030 F 30

5005 F 5 5018 F 18 5031 F 31

5006 F 6 5019 F 19 5032 F 32

5007 F 7 5020 F 20 5033 F 33

5008 F 8 5021 F 21 5034 F 34

5009 F 9 5022 F 22 5035 F 35

5010 F 10 5023 F 23 5036 F 36

5011 F 11 5024 F 24 5037 F 37

5012 F 12 5025 F 25 5038 F 38

5013 F 13 5026 F 26 5039 F 39

A-11

Bar Code Information

Page 184 of the Symbol Technologies P470 user manual — A-12
Pagina 184 · klik om te vergroten
Pagina 184

Table A-5. ASCII Character Set (Continued)

6042 * 6049 1 6056 8

6043 + 6050 2 6057 9

6044 Undefined 6051 3 6058 Enter

6045 - 6062 4 6059 Num Lock

6046 . 6063 5 6060 00

6047 / 6064 6

6048 0 6065 7

7001 Break 7008 Backspace 7015 Up Arrow

7002 Delete 7009 Tab 7016 Dn Arrow

7003 Pg Up 7010 Print Screen 7017 Left Arrow

7004 End 7011 Insert 7018 Right Arrow

7005 Pg Dn 7012 Home 7019 Back Tab

7006 Pause 7013 Enter

7007 Scroll Lock 7014 Escape

A-12

Show 14 more labels / short text on this page
Numeric · Keystroke Numeric · Keystroke Numeric · Keystroke · Keypad · Keypad · Keypad · Extended · Keystroke Extended · Keystroke Extended · Keystroke · Keypad · Keypad · Keypad
Page 185 of the Symbol Technologies P470 user manual — B-1
Pagina 185 · klik om te vergroten
Pagina 185

Appendix B Automatic Project Download

The Phaser P470/P370 RF scanner is shipped from the factory with a pre-installed default application. This fully functional application allows the scanner to be used “out of the box”. If you need to load your own application into the scanner, the “Automatic Project Download” feature will simplify the process.

When the default application is running, and the scanner is placed into its paired cradle, the scanner will query the MCL-Link host for data in a file named “PHASER.CFG”. The scanner will use the information in this file to find the project directory which the user wishes to have loaded into the scanner, and will then execute the PROJECT.CMD” script which exists in the directory. This script will automatically download all program and data files relevant to the project to the scanner and will reset the scanner making it ready to run the user’s application.

In order to utilize this mechanism, the user needs only generate the PHASER.CFG file and place it in the directory specified in the MCL-Link setup screen as the “General path for data files”. Any text editor may be used to create this file; the contents of the file are as follows:

X|

The X| at the beginning of the line are required for the MCL-Net CR command to recognize this file and read the data. The path name should include the entire path hierarchy. Also, all backslashes (\) in the path name should be replaced with the string “\5C”, so that the MCL code running on the scanner does not inadvertently convert part of the path name to the equivalent Hex Character.

An example PHASER.CFG file is shown below:

x|c:\5Cmcl-p460\5Cdesigner\5Csample1.prj

B-1

Page 186 of the Symbol Technologies P470 user manual — B-2
Pagina 186 · klik om te vergroten
Pagina 186

The PROJECT.CMD file will be automatically generated by the MCL-Designer application.

B-2

Page 187 of the Symbol Technologies P470 user manual — Table C-1. RF Channels Per Country
Pagina 187 · klik om te vergroten
Pagina 187

Appendix C Radio Channels

Cordless Phaser RF Channels Per Country

The cordless Phaser scanner operates continuously on a single, programmable channel (frequency) between 2.402 GHz (channel 02) and 2.483 GHz (channel 83).

A maximum of 82 channels are available. Not all channels are available in all countries. If a channel is not legal to use in your country, an error beep will be heard instead of a successful warble.

See Table C-1 for a list of channel availability by Country.

operation in all countries listed in Table C-1, not all country configurations are available for order. Consult your local Symbol reseller for more information.

Table C-1. RF Channels Per Country

ARGENTINA 82 2 83

AUSTRALIA 82 2 83

AUSTRIA 82 2 83

BELGIUM 82 2 83

Country Total Channels · First Channel · Last Channel

Page 188 of the Symbol Technologies P470 user manual — Table C-1. RF Channels Per Country (Cont’d)
Pagina 188 · klik om te vergroten
Pagina 188

Table C-1. RF Channels Per Country (Cont’d)

BOLIVIA 82 2 83

BRAZIL 82 2 83

CANADA 82 2 83

CHILE 82 2 83

COLOMBIA 82 2 83

COSTARICA 82 2 83

CZECH REPUBLIC 82 2 83

DENMARK 82 2 83

DOMINICAN REPUBLIC 82 2 83

FINLAND 82 2 83

FRANCE 7 47 53

GERMANY 82 2 83

GREECE 82 2 83

GUATEMALA 82 2 83

HONDURAS 82 2 83

HONG KONG 82 2 83

HUNGARY 82 2 83

INDONESIA 82 2 83

ICELAND 82 2 83

IRELAND 82 2 83

ISRAEL 36 20 55

ITALY 82 2 83

JAPAN 80 2 81

KOREA 82 2 83

Country Total Channels · First Channel · Last Channel

Page 189 of the Symbol Technologies P470 user manual — Table C-1. RF Channels Per Country (Cont’d)
Pagina 189 · klik om te vergroten
Pagina 189

Table C-1. RF Channels Per Country (Cont’d)

LUXEMBOURG 82 2 83

MALAYSIA 82 2 83

MEXICO 32 52 83

NETHERLANDS 82 2 83

NEW ZEALAND 82 2 83

NICARAGUA 82 2 83

NORWAY 82 2 83

PERU 82 2 83

PHILIPPINES 82 2 83

POLAND 82 2 83

PORTUGAL 82 2 83

ROMANIA 82 2 83

RUSSIA 82 2 83

SAUDI ARABIA 82 2 83

SINGAPORE 37 47 83

SLOVENIA 82 2 83

SOUTH AFRICA 82 2 83

SPAIN 27 47 73

SWEDEN 82 2 83

SWITZERLAND 82 2 83

TAIWAN 80 2 81

THAILAND 82 2 83

TURKEY 82 2 83

UNITED ARAB EMIRATES 82 2 83

Show 4 more labels / short text on this page
Radio Channels · Country Total Channels · First Channel · Last Channel
Page 190 of the Symbol Technologies P470 user manual — Table C-1. RF Channels Per Country (Cont’d)
Pagina 190 · klik om te vergroten
Pagina 190

Table C-1. RF Channels Per Country (Cont’d)

UNITED KINGDOM 82 2 83

URUGUAY 82 2 83

UNITED STATES (US) 82 2 83

VENEZUELA 82 2 83

Country Total Channels · First Channel · Last Channel

Page 191 of the Symbol Technologies P470 user manual — D-1
Pagina 191 · klik om te vergroten
Pagina 191

Appendix D Messages and Error Codes

Introduction

This Appendix contains information on messages and error codes displayed on the scanner.

Messages

The scanner displays messages when certain actions are performed. If the scanner displays a message that is unfamiliar, contact the Symbol Support Center on page xi.

Table D-1. Scanner Messages

Unit Cradled Scanner is properly inserted in the cradle

Battery Temperature Out Of Range

Battery temperature is out of range. Contact a Symbol Support Center on page xi.

Pairing Unsuccessful Push ENTER & Try Again

The scanner has not been successfully paired with the base (cradle). Press ENTER and then try to pair the scanner and cradle again.

Failed to initiate download-Press ENTER

New firmware was not successfully downloaded to the device. This message can be displayed while downloading new firmware to either the scanner or base. Cycle power (power off then on) to the base and try again.

D-1

Message Description

Page 192 of the Symbol Technologies P470 user manual — D-2
Pagina 192 · klik om te vergroten
Pagina 192

Table D-1. Scanner Messages (Continued)

Recharge Battery Battery is close to complete discharge. Recharge the battery

Communication Errors

Scanning Transmission Range

A communication error will occur when the scanner, cradle or host fails to properly communicate. When a communication error occurs while using the default application, the scanner emits 4 beeps (LO HI LO HI) and displays a "Failed Communication" error message.

Failed Communication Error 015 Push ENTER

The three-digit error code on the scanner's screen indicates what type of communication problem has occurred. For example, error code 015 generally indicates the scanner is out of RF range, is not properly paired with the base, or the base may have lost power. For a complete list of error codes, see Table D-2.

Table D-2. Error Codes

Error Code Type Description

002 Serial Protocol Error RS-232 host does not recognize character(s) transmitted from scanner.

003 Serial Protocol Error Handshaking failure.

005 Serial Protocol Error Scanner does not recognize character(s) transmitted from RS-232 host.

008 SYNAPSE Error Synapse host does not recognize character(s) transmitted from scanner.

009 SYNAPSE Error Synapse transmission failed. Synapse cable may not be properly installed.

D-2

Message Description

Page 193 of the Symbol Technologies P470 user manual — D-3
Pagina 193 · klik om te vergroten
Pagina 193

Messages and Error Codes

Table D-2. Error Codes

Error Code Type Description

015 RF Communication Error

Scanner is out of range, not properly paired to a base or the base may have lost power.

016 RF Communication Error

The base to which the scanner is paired has been paired with another scanner.

017 RF Communication Error

Scanner is out of range.

018 MCL-Link Error A Synapse cable cannot communicate with MCL-Link. Reconnect to the host using an RS-232 cable and then cycle power (power off then on) to the base.

020 RF Communication Error

Previous RF transmission not yet complete.

021 Memory Allocation Error For repeated occurrence contact Customer Service.

024 RF Communication Error

The base is not responding. Cycle power (power off then on) to the base.

247 MCL-Link Error MCL-Link responded with a busy message.

249 MCL-Link Error MCL-Link rejected the command.

253 MCL-Link Error MCL-Link or 123Scan did not respond. The base may not be properly connected to the host. make sure the RS-232 cable is properly connected and the base is receiving power. If the problem persists, cycle power (power off then on) to the base.

display but are reported in System Variable 97 immediately after the execution of the offending command (SO, SI, NO or NI).

D-3

Page 194 of the Symbol Technologies P470 user manual — D-4
Pagina 194 · klik om te vergroten
Pagina 194

D-4

Page 195 of the Symbol Technologies P470 user manual — Inhoudsopgave
Pagina 195 · Inhoud
Inhoud

Inhoud

About This Manualp.11Introductionp.11Chapter Descriptionsp.11Notational Conventionsp.11Related Publicationsp.12Service Informationp.12Symbol Support Centerp.13Warrantyp.15Warranty Coverage and Procedurep.16Generalp.16Chapter 1 The P470/P370 RF Scannerp.17Introductionp.17Rechargeable Batteryp.18The Cradlep.18Quick Startup Instructionsp.19Commonly Used P470/P370 Programming Bar Codep.20Chapter 2 Set Upp.21Introductionp.21Unpackingp.21Setting Up the Cradlep.21Connecting to a Hostp.21Wall Mountingp.24Pairing the Scanner with the Cradlep.26Optimizing RF Performancep.27Mountingp.27Coexistence in Spectrum24 Environmentsp.27Phaser-to-Phaser Co-Existencep.28Charging the Batteryp.28Using the Cradlep.29Using the UBC 2000p.29Battery Chargep.29Chapter 3 Operationp.31Introductionp.31Default Applicationp.31Initial Powerupp.32Scan and Transmit Applicationp.32Eliminating Repetitive Scanningp.34Communication Errorsp.35RF Communication Errorsp.35Host / Cradle Communication Errorsp.36System Menup.37123Scanp.47Suffix Valuesp.48Scanningp.52Scan the Entire Symbolp.52Hold at an Anglep.53Decode Zonep.54Keypad Operationp.56Troubleshootingp.58Chapter 4 Maintenance And Specificationsp.61Introductionp.61Maintenancep.61Changing the Batteryp.61Removing the Batteryp.62Replacing the Batteryp.62Charge Status LED Indicationsp.63Technical Specificationsp.64Cradle Pin-outsp.66Beeper Indications / Default Application Error Codesp.67Chapter 5 Parameter Menusp.69Introductionp.69Operational Parametersp.69Set Default Parameterp.75Communication Protocolp.76Scan & Transmit Applicationp.76Host Typep.77RS-232C Host Typesp.77Host Response Timeoutp.80RF Channelp.81RF Retriesp.81Sleep Timep.83Decimal Separatorp.84Key Clickp.85Beeper Tonep.86Beeper Volumep.87Power Detect Beepp.88Beep After Good Decodep.89Laser On Timep.90Transmit “No Read” Messagep.91Linear Code Type Security Levelp.92Linear Security Level 1p.92Linear Security Level 2p.92Linear Security Level 3p.93Linear Security Level 4p.93Bi-directional Redundancyp.94Autodiscriminate Response Timep.95Enable/Disable UPC-E/UPC-A/UPC-E1p.96Enable/Disable EAN-8/EAN-13p.97Enable/Disable Bookland EANp.98Decode UPC/EAN Supplementalsp.99Decode UPC/EAN Supplemental Redundancyp.100Transmit UPC-A/UPC-E/UPC-E1 Check Digitp.101UPC-A Preamblep.102UPC-E Preamblep.103UPC-E1 Preamblep.104Convert UPC-E to UPC-Ap.105Convert UPC-E1 to UPC-Ap.106EAN-8 Zero Extendp.107Convert EAN-8 to EAN-13 Typep.108UPC/EAN Security Levelp.109UPC/EAN Security Level 0p.109UPC/EAN Security Level 1p.109UPC/EAN Security Level 2p.110UPC/EAN Security Level 3p.110UPC/EAN Coupon Codep.111Enable/Disable Code 128p.112Enable/Disable UCC/EAN-128p.113Lengths for Code 128p.113Enable/Disable Code 39p.114Enable/Disable Trioptic Code 39p.115Set Lengths for Code 39p.116Code 39 Check Digit Verificationp.118Transmit Code 39 Check Digitp.119Enable/Disable Code 39 Full ASCIIp.120Convert Code 39 to Code 32p.121Code 32 Prefixp.122Enable/Disable Code 93p.123Set Lengths for Code 93p.124Enable/Disable Interleaved 2 of 5p.126Set Lengths for Interleaved 2 of 5p.127I 2 of 5 Check Digit Verificationp.129Transmit I 2 of 5 Check Digitp.130Convert I 2 of 5 to EAN-13p.131Enable/Disable Discrete 2 of 5p.132Set Lengths for Discrete 2 of 5p.133Enable/Disable Codabarp.135Set Lengths for Codabarp.136CLSI Editingp.138NOTIS Editingp.139Enable/Disable MSI Plesseyp.140Set Lengths for MSI Plesseyp.141MSI Plessey Check Digitsp.143Transmit MSI Plessey Check Digitp.144MSI Plessey Check Digit Algorithmp.145Transmit Code ID Characterp.146Symbol Code ID Charactersp.146Pause Durationp.148RS-232C Parametersp.149Baud Ratep.149Baud Rate (Continued)p.150Parityp.151Parity (Continued)p.152Check Receive Errorsp.153Hardware Handshakingp.154Hardware Handshaking (Continued)p.155Hardware Handshaking (Continued)p.156Software Handshakingp.156Software Handshaking (Continued)p.157Software Handshaking (Continued)p.158Host Serial Response Time-outp.158RTS Line Statep.159Stop Bit Selectp.160ASCII Formatp.160Intercharacter Delayp.161MCL-Net Parametersp.161MCL-Net Baud Ratep.161MCL-Net Baud Rate (Continued)p.163MCL-Net Hex Addressing Modep.164Scanner Addressp.165MCL-Net Transmit Retriesp.165MCL-Net Frame Timeoutp.165Scanner Decode Beep Typep.166Long Range Scanning Bar Codesp.167Aim Modep.167Aim Durationp.168Numeric Bar Codesp.169Cancelp.171Appendix A Bar Code Informationp.173UCC/EAN-128p.173AIM Code Identifiersp.175Appendix B Automatic Project Downloadp.185Appendix C Radio Channelsp.187Cordless Phaser RF Channels Per Countryp.187Appendix D Messages and Error Codesp.191Introductionp.191Messagesp.191Communication Errorsp.192Scanning Transmission Rangep.192Indexp.195Numericsp.195Ap.195Bp.195Cp.196Dp.196Ep.197Fp.197Hp.197Ip.197Kp.197Lp.197Mp.197Np.197Op.197Pp.197Qp.198Rp.198Sp.198Tp.198Up.199Vp.199Wp.199Yp.199Quick Startup Instructionsp.202
Page 196 of the Symbol Technologies P470 user manual — C
Pagina 196 · klik om te vergroten
Pagina 196

check digit algorithm 5-77 check digits 5-75 enable/disable 5-72 set lengths 5-73, 5-74 transmit check digit 5-76 numeric bar codes . . 5-101, 5-102, 5-103 pause duration 5-80 RS-232C parameters

C carriage return 3-17, 3-18 charge status indicator light 1-2 charge status LED indications 4-3 charging the battery 2-8, D-1 code identifier A-3 co-existence

phaser-to-phaser 2-8 Spectrum24 2-7 communication protocol 3-2, 3-8, 5-8

handshaking 5-89 set default 5-7 sleep time 5-15 system code 3-12 system menu 1-4, 3-7 transmit code ID character 5-78, 5-79 transmit "no read" 5-23 UPC-A/UPC-E

MCL-Net 3-8, 5-8, 5-9, 5-93 RS232 2-2, 3-8, 5-8, 5-10, 5-81 scan & transmit app 3-2, 3-8, 5-2, 5-8 Synapse 2-3, 3-8, 5-8 connecting to a host 2-1 cradle 1-2, 2-1

transmit check digit 5-33 UPC/EAN

charging in the cradle 2-9 description of basic operation . . . 1-2, 4-3 LED indicator status 4-3 pin outs 4-6 setting up the cradle 2-1, 2-6, 2-7

bookland EAN 5-30 convert EAN-8 to EAN-13 type . 5-40 convert UPC-E to UPC-A . . 5-37, 5-38 coupon code 5-43 EAN zero extend 5-39 EAN-8/EAN-13 5-29 enable/disable 5-28 security level 5-41, 5-42 supplemental redundancy 5-32 supplementals 5-31 UPC-A preamble 5-34 UPC-E preamble 5-35 UPC-E1 preamble 5-36 battery 1-2

D data formatting 3-17 dead zone 3-23 decode depth of field 3-24 decode options 5-23 decode symbologies/capability 4-4 Default Application 3-1

Scan and Transmit Application . . 3-2, 5-8 default settings 5-2

battery charge 2-8, 2-9, 4-7 battery temperature range message . . D-1 changing 4-2 changing/replacing 4-1 charging 2-9 checking battery charge level 3-14 beeper

resetting default application 3-10 resetting default scanning parameter . . 5-7 table of default parameters 5-2 default table 5-2 depth of field/decode zone 3-24 Dimensions 4-5 downloading

ADF rules 3-17 applications 3-9 automatic upgrade process B-1 durability 4-4

beeper indications 4-7 beeper operation 4-4 beeper tone 5-18 beeper volume 5-19 boot up the scanner 3-1, 3-27

Index-2

Page 197 of the Symbol Technologies P470 user manual — K keypad
Pagina 197 · klik om te vergroten
Pagina 197

E eliminating repetitive scanning 3-4 ENABLE UPC-E1 5-28 error beep sequences 4-7 error codes 3-5, 4-7, D-2 error messages and codes D-1 Exit System Menu 3-16

loading system code 3-12

M maintenance 4-1 Manual Data Entry

alpha data 3-3, 3-26 decimal points 3-27 example keying in data 3-26 numeric data 3-3 maximum tilt angles 3-23 MCL Net 3-8, 5-8

F firmware version 3-7, 3-15 formatting data 3-17

baud rate 5-6, 5-93, 5-95 frame timeout 5-6, 5-97 hex addressing mode 5-6, 5-96 parameters 5-93 scanner address 5-6 transmit retries 5-6, 5-97 messages D-1

H hardware handshaking 5-86 humidity 4-4

I instructions

N notational conventions ix numeric bar codes 5-101, 5-102 numeric data entry 3-2, 3-26

quick startup 1-3 introduction 1-1

K keypad

access the system menu 3-7 alpha data entry 3-3 enabling/disabling the keypad 3-26 entering a blank space 3-27

O Operational parameters 5-1

P P370 ALR (see ALR) 5-99 pairing long range scanners 2-6 pairing the scanner and cradle 2-6 parameters

a dash 3-27 a decimal point 3-27 example keying in data 3-27 manually resetting the scanner . 3-1, 3-28 numeric data entry 3-2 operation and layout 3-26 quantity entry 3-4

clear an ADF rule 3-17 reset default application 3-10 set all defaults 5-7 table of default settings 5-2 pause duration 5-80 pin outs

L laser classification 4-5 LED status on cradle 4-3 loading

cradle 4-6 pitch 4-4 Power Detect Beep 5-20 print contrast minimum 4-4

loading base station code 3-13 loading new applications 3-9

Index · Index-3

Page 198 of the Symbol Technologies P470 user manual — Q
Pagina 198 · klik om te vergroten
Pagina 198

Q quick startup instructions 1-3

clearing ADF rules 3-17 default application 3-10 default scanning parameters 5-7 set length

R reboot scanner 3-1, 3-28 Related Publication x resetting the scanner 3-1, 3-28 Returns to Application 3-16 RF

codabar 5-68 code 39 5-48 code 93 5-56 discrete 2 of 5 5-65 interleaved 2 of 5 5-59 MSI Plessey 5-73 Set Scanner ID 3-8 setup

optimizing RF performance 2-7 pairing scanner to cradle 2-6 RF channel 3-8, 5-13, C-1 RF communication errors . . 3-5, 3-28, D-1 RF retries 2-8, 5-13 roll tolerance 4-4 RS-232C 2-2, 3-8, 5-8, 5-10

quick startup instructions 1-3 sleep time 5-15 software version

see firmware version 3-7, 3-15 spare pairing bar code 2-6 specular reflection 3-23 stay awake 5-15 suffix values

ASCII format 5-92 baud rate 5-81, 5-82 check receive errors 5-85 hardware handshaking . . 5-86, 5-87, 5-88 host serial response time-out 5-90 host types 5-9 intercharacter delay 5-93 parity 5-83, 5-84 RTS line state 5-91 software handshaking . . . 5-88, 5-89, 5-90 stop bit select 5-92

Enter (carriage return) 3-18 Tab 3-20 symbol code identifier characters A-6 symbol support center xi Synapse connectivity 2-3, 3-8, 5-8 system code

bar code 3-12 system menu 3-7

S Scan and Transmit Application 3-2

accessing 3-7 Back To Main 3-8, 3-13, 3-14 Battery Check 3-14 exiting system menu 3-16 load new application 3-9 navigating the system menu 3-7 Set Contrast 3-8 set default application 3-10 Set Default Params 3-14 set RF channel 3-8 version 3-7, 3-15

communication protocol .3-2, 3-8, 5-2, 5-8 manual alphanumeric entry 3-2, 3-3 quantity entry 3-2, 3-4 scan repetition rate 4-4 scanner address 5-97 Scanner Decode Beep Type 5-98 scanner decode beep type 5-98 scanner emits transmit errors 3-28 scanner ID 3-8, 5-97 Scanning 3-2 scanning

T tab 3-20

eliminating repetition 3-4 service information x

set defaults · Index-4

Page 199 of the Symbol Technologies P470 user manual — U
Pagina 199 · klik om te vergroten
Pagina 199

technical specifications 4-4 temperature

unit cradled message 2-9, D-1 unpacking 2-1

battery D-1 operating 4-4 storage 4-4 transmit code ID character 5-78, 5-79 trigger pull to scan 5-99 trigger release to scan 5-99 troubleshooting 3-28

V version 3-7, 3-15

W wake up 3-2 working range 3-24

messages and error codes D-1

U UCC/EAN-128 A-1

Y yaw 4-4

Index · Index-5

Page 200 of the Symbol Technologies P470 user manual — U
Pagina 200 · klik om te vergroten
Pagina 200

Index-6

Page 201 of the Symbol Technologies P470 user manual — What can we do to further improve our manuals? ___________________________________________________________ ___________________________________________________________
Pagina 201 · klik om te vergroten
Pagina 201

Tell Us What You Think...

We’d like to know what you think about this Manual. Please take a moment to fill out this questionnaire and fax this form to: (631) 738-3318, or mail to:

Symbol Technologies, Inc. One Symbol Plaza M/S B-4 Holtsville, NY 11742-1300 Attention: Technical Publications Manager

User’s Manual Title:

(please include revision level)

How familiar were you with this product before using this manual?

Very familiar Slightly familiar Not at all familiar

Did this manual meet your needs? If not, please explain. ___________________________________________________________ ___________________________________________________________

What topics need to be added to the index, if applicable?

What topics do you feel need to be better discussed? Please be specific

What can we do to further improve our manuals?

Thank you for your input—We value your comments.

Page 202 of the Symbol Technologies P470 user manual — 72-38495-03 Revision B — December 2001
Pagina 202 · klik om te vergroten
Pagina 202

Quick Startup Instructions

Below is an index of Quick Startup Instructions to help get you up and going quickly. The index is listed in a step by step order beginning with step 1, Setting up the System.

Mandatory steps are designated by an asterisk (*). If an item has multiple pages referenced, the most important reference is in bold.

1. Setting Up the System
  • Connecting the cradle to a host * 2-1

- RS-232 connection 2-2

- Synapse connection (keyboard wedge, USB, etc.) 2-3

  • Charging the battery * 1-2, 2-8
  • Pairing the scanner with the cradle * 2-6

- RF channel 3-8, 5-13, C-1

- Coexisting in Spectrum24 environments 2-7

2. Using the Default Applications
  • Overview of Scan and Transmit application* 3-2
  • Keypad operation 3-2, 3-3, 3-26
  • Eliminating repetitive scanning 3-4
  • Selecting the host communication protocol 3-2, 3-8, 5-8

- RS-232 baud rate 5-81

3. Programming an Advanced Data Formatting Rule Using 123Scan 3-17
  • Suffix values (appending Enter key and Tab) 3-18
4. Troubleshooting Problems
  • Troubleshooting table 3-28
  • Communication errors 3-5, D-2
  • Beeper indications and default application error codes 4-7
  • Cradle LED indications 4-3

Symbol Technologies, Inc. One Symbol Plaza, Holtsville N.Y. 11742-1300

72-38495-03 Revision B — December 2001

PRG Page

Codes weergeven

Foutcodes

Wat de op het display getoonde foutcodes betekenen en hoe u ze wist.

CodeBetekenisOplossing
002RS-232 host does not recognize character(s) transmitted from scanner. p.192
003Handshaking failure. p.192
005Scanner does not recognize character(s) transmitted from RS-232 host. p.192
008Synapse host does not recognize character(s) transmitted from scanner. p.192
009Synapse transmission failed. Synapse cable may not be properly installed. p.192
Probleemoplossing

Probleemoplossing

Veelvoorkomende problemen, mogelijke oorzaken en oplossingen.

ProbleemMogelijke oorzaakOplossing
General problem solving• Check that the power supply is attached to the cradle. • Check for loose cable connections at the cradle, AC power supply, or host device. • Make sure the scanner and cradle have been successfully paired. • Check the scanner’s battery charge level. See Battery Check on page 3-14. • Make sure the device is programmed to read the type of bar code you want to scan. • Check the symbol to make sure it is not defaced. • Try scanning another similar symbol of the same code type. • Be sure you’re within the proper scanning decode range. • Make sure you are within the proper RF transmission range. • Cycle power (power off then on) to the base. • Reboot (reset) the scanner (hold down the ENTER key for about 30 seconds) and try scanning again. p.58
The scanner emits error beeps after decoding a bar code.• Check that the cradle is powered up and that it’s cable connections are secure. See Setting Up the Cradle on page 2-1. • Check that the scanner is successfully paired with the cradle. See Pairing the Scanner with the Cradle on page 2- 6. • Check that you are within transmitting range. See Communication Errors on page 3-5 and Appendix D, Messages and Error Codes. p.58
The scanner does not scan the programming bar codes in this PRG.• For MCL-Designer generated applications, put the scanner into “Scan Parameter” mode in the system menu (see Scan Parameters on page 3-14). • For the default application running on a previous version of firmware (Revision F or lower, such as E), put the scanner into “Scan Parameter” mode in the system menu (see Scan Parameters on page 3-14). For instructions on how to check the scanner’s firmware version, see Version on page 3-15. p.59
The PC cannot download an application to the scanner.• Check to make sure you are using an RS-232 cable. The application can not be downloaded to a scanner using a Synapse cable. • Make sure the scanner and cradle are successfully paired. • Check to make sure the power supply is connected to the base. • If the problem continues, cycle power to the base (powered off then on). p.59
Received an 015 communication error while using a Synapse cable.• The cables connected to the cradle were not connected in the correct sequence. Before power is applied to the cradle, the Synapse cable must be connected to the cradle AND the flying power lead plugged in. See Using A Synapse Cable on page 2-3 for more information p.59
The P370 ALR scanner will not pair with a PL370 cradle.• To pair a long range P370 ALR scanner with a PL370 cradle, attach the spare pairing bar code label to the cradle and scan the bar code. For additional information, see Pairing the Scanner with the Cradle on page 2-6. p.59
The Scanner will not load my ADF rule.• Software download to the scanner while the scanner is running the default application. • Check that the scanner is successfully paired with the cradle (see page 2-6). • Check that the cradle and PC are connected using an RS-232 cable. • Software download or scanning a bar code sheet while the scanner is running an MCL-Designer generated application • Erase the MCL-Designer application from the scanner’s memory by scanning the “Reset Default Application” bar code on page 3-10. • The default application is now reinstalled and an ADF rule can be loaded. p.60

Vraag stellen over de Symbol Technologies P470

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Symbol Technologies P470

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Symbol Technologies P470 handleiding-pdf

202 pagina's·1.7 MB·Scanner·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…