Document No. 49-0002-011 Rev. B Installation, Operation & Diagnostics for the MIU202T Industrial Grade, Bell 202T Standalone Modem.
Document No. 49-0002-011 Rev. B Telenetics Corporation 25111 Arctic Ocean Lake Forest, California 92630 (949)455-4000 Fax (949)455-4010.
MIU202T Installation, Operation & Diagnostic s Edition: December 28, 2000 Page 1 TABLE OF CONTENTS 1. STANDARDS .............................................................................................. 2 2. PRODUCT OVERVIEW ..................
MIU202T Installation, Operation & Diagnostic s Edition: December 28, 2000 Page 2 1. STANDARDS Meets FCC Rules Part J, Subpart 15, Class A for radiated em issions.
MIU202T Installation, Operation & Diagnostic s Edition: December 28, 2000 Page 3 3. GENERAL PRODUCT SPECIFICATIONS Dimensions: 5.3 x 4.0 x 1.375 inches Weight: 1 l b Voltage Supply : Standard Model: 40 to 270VDC 40 to 270VAC, 50/60Hz LV Model (Suffix “-LV”): 9 to 36VDC Current Requirements : 12VDC 24VDC 125VDC 120VAC 220VAC 65mA 27m A 7.
MIU202T Installation, Operation & Diagnostic s Edition: December 28, 2000 Page 4 4. MODEM SPECIFICATIONS Modulation: Bell202T Modulation Type: FSK Synch/Async: Asynchronous Only Data Rate: 0 – 1.
MIU202T Installation, Operation & Diagnostic s Edition: December 28, 2000 Page 5 Other Features Receiver Equalization: Compromise Equalization Self Test Diagnostics: None Local Analog Loopback: Se.
MIU202T Installation, Operation & Diagnostic s Edition: December 28, 2000 Page 6 5. ANALOG LINE SPECIFICATIONS The MIU202T contains analog circuit ry for connection to the public conditioned or unconditi oned, Bell type 3002, 2 or 4-wi re, full duplex voice grade leased lines or metallic lines (eg; pilot wires).
MIU202T Installation, Operation & Diagnostic s Edition: December 28, 2000 Page 7 6. ANALOG MICROWAVE INTERFACE The MIU202Tis designed to interface to a Microwave radio voice channel network with the fo llowing specifications: Phase Jitter (10 to 300Hz)1 degree peak-to-peak, max.
MIU202T Installation, Operation & Diagnostic s Edition: December 28, 2000 Page 8 Crosstalk (unintelligib le): Adjacent channel 28dBrnc0 ma ximum (24 455B weighted noise at 0 dBmO dB rnc0 typical).
MIU202T Installation, Operation & Diagnostic s Edition: December 28, 2000 Page 9 7. POWER CONNECTIONS.
MIU202T Installation, Operation & Diagnostic s Edition: December 28, 2000 Page 10 8. SERIAL DATA PORT PIN-OUTS.
MIU202T Installation, Operation & Diagnostic s Edition: December 28, 2000 Page 11 9. DIP SWITCH FUNCTIONS IMPORTANT NOTE: Invert m odem to view di p switches as shown above Table 1 Switch Function.
MIU202T Installation, Operation & Diagnostic s Edition: December 28, 2000 Page 12 Table 2: RTS/CTS Delay Time 2 Wire 4 Wire Switched Carrier Constant Carrier Switch 4 Switch 5 Switch 9 Soft Carrie.
MIU202T Installation, Operation & Diagnostic s Edition: December 28, 2000 Page 13 10. MODEM CONFIGURATION The following table provi des the Dip Switch setti ngs required for most modem application.
MIU202T Installation, Operation & Diagnostic s Edition: December 28, 2000 Page 14 11. LED INDICATOR.
MIU202T Installation, Operation & Diagnostic s Edition: December 28, 2000 Page 15 12. OUTLINE DRAWING & MOUNTING.
MIU202T Installation, Operation & Diagnostic s Edition: December 28, 2000 Page 16 13. DIAGNOSTICS The following pages provide hard ware techniques for diagnosing comm unication problems and t hereby isolating the problem at the local modem, the remote modem or the interconn ecting line.
MIU202T Installation, Operation & Diagnostic s Edition: December 28, 2000 Page 17 Set Dip Switch 1 OFF (TxA = -10dBm) and Di p Switch 3 OFF (RxA = -43dBm). CD will be ON. Run a test message at TxD and verify that the sam e message is received at RxD with no data errors.
MIU202T Installation, Operation & Diagnostic s Edition: December 28, 2000 Page 18 (c) REMOTE DIGITAL LOOPBACK – 4/Wire Network (Figure 5) Configure both the local and rem ote modem s as follows:.
MIU202T Installation, Operation & Diagnostic s Edition: December 28, 2000 Page 19 (d) LINE DIAGNOSTICS (i) Typical m odem configurati on for 4-wire Point-to-Point system… Switch 1 = ON (TxA = 0dBm ) Switch 3 = ON (RxA = -33dBm ) Switch 4 = OFF (RTS/CTS = 1m s) Switch 5 = OFF (RTS/CTS = 1m s) Switch 6 = ON (Constant Carrier mode).
MIU202T Installation, Operation & Diagnostic s Edition: December 28, 2000 Page 20.
MIU202T Installation, Operation & Diagnostic s Edition: December 28, 2000 Page 21.
MIU202T Installation, Operation & Diagnostic s Edition: December 28, 2000 Page 22.
MIU202T Installation, Operation & Diagnostic s Edition: December 28, 2000 Page 23 Addendum: 202T built on 1224 printed circuit board. Test Functions: A mom entary push button swit ch and two yellow LED’s are provi ded to perform the test funct ions.
Een belangrijk punt na aankoop van elk apparaat Telenetics MIU202T Modem (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Telenetics MIU202T Modem heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Telenetics MIU202T Modem vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Telenetics MIU202T Modem leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Telenetics MIU202T Modem krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Telenetics MIU202T Modem bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Telenetics MIU202T Modem kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Telenetics MIU202T Modem . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.