Instruction Manual ON OFF POWER ALARM INPUT UNIT C-AL80(L) C-AL80(H) Thank you for purchasing TOA's Alarm Input Unit. Please carefully follow the instructions in this manual in order to ensure long, trouble-free use of your Alarm Input Unit.
2 T ABLE OF CONTENTS 1. SAFETY PRECA UTIONS ................................................................................ 3 2. GENERAL DESCRIPTION ............................................................................. 4 3. HANDLING PRECA UTIONS .
3 1. SAFETY PRECA UTIONS • Before installation or use, be sure to carefully read all the instructions in this section in order to ensure long, trouble-free operation. • Be sure to follow all the precautionary instructions in this section, which contain important warnings regarding safety.
4 Indicates a potentially hazardous situation which could result in moderate or minor personal injury, and/or property damage if ignored or mishandled. CA UTION When Installing the Alarm Input Unit • Never insert nor remove the power supply plug with wet hands, as an electric shock may result.
5 1 2 3 4 Cov er The inside of the cov er ON OFF POWER ON OFF UNIT No. LEVEL REMOTE OFF ABBREVIA TION No.9001 REMOTE ALARM ABBREVIA TION No.1 REMOTE ON EDGE 1234 12 34 (1) Power Switch [ON/OFF ] Used to turn power on and off. (2) Power Indicator Lights when the Power switch is set to ON.
6 [Rear P anel] 5 6 7 8 9 10 11 ALARM/ / REMOTE IN CAMERA SELECT OUT ALARM / REMOTE OUT MASTER / SLA VE RS-232C OFF ON TERMINA TION (5) Power Inlet Connects to the supplied power supply cord. (6) Alarm/Remote Input Terminal [Alarm/Remote Input] Use the Mode Selection switch (4) to perform input function settings.
7 123 4 1 32 33 64 65 96 97 128 129 160 161 192 193 224 225 256 Master Unit's Switch Setting Master Unit 1 Slav e Unit 2 Slav e Unit 3 Slav e Unit 4 Slav e Unit 5 Slav e Unit 6 Slav e Unit 7 Slav e Unit 8 123 4 LEVEL REMO TE OFF ABBREVIA TION No.
8 3 REMO TE OFF REMO TE ON 4 LEVEL EDGE 5.3. Alarm/Remote Output Settings It cannot be used. Please fix to the "Remote OFF" (Factory-preset position: "Remote OFF") 5.4. Alarm Interval Settings Set the alarm time interval to "Edge" or "Level" with Model Selection switch 4.
9 12 3 4 G N D 56 7 8 G N D 91 0 1 1 1 2 G N D 13 14 15 16 G N D 17 18 19 20 G N D 21 22 23 24 G N D 25 26 27 28 G N D 29 30 31 32 G N D 6. USING THE ALARM/REMO TE FUNCTION 6.1. Alarm/Remote Input The Alarm/Remote input terminals on the rear panel are designed to be used for both alarm and remote inputs.
10 7. CONNECTION EXAMPLE 7.1. Connection to the C-RM500 Remote Controller Monitor C-RM500 Alarm Input Unit C-AL80 Alarm/Remote Input RS-232C Sensor Sensor 1 4 6 9 5,10 Sensor 1 4 6 9 5,10 Multi-Switch.
11 Unit Number Setting switch (3) Unit Number Setting switch (3) Unit Number Setting switch (3) Unit Number Setting switch (3) C-AL80 Alarm Input Unit Master Unit Slave Unit 1 Slave Unit 2 Slave Unit 7 123 4 Unit No. OFF ON 123 4 Unit No. OFF ON 123 4 Unit No.
12 123 4 123 4 123 4 123 4 123 4 123 4 123 4 123 4 Unit No. switch setting Master Unit Slave Unit 1 Slave Unit 2 Slave Unit 3 Slave Unit 4 Slave Unit 5 Slave Unit 6 Slave Unit 7 123 4 Unit Number ON OFF 8.
13 1 4 2 5 3 1 4 2 5 3 1 4 2 5 3 Master/Slave terminal Master/Slave terminal • Master/Slave Terminal Cable Type Use the supplied DIN plug and the twisted pair cable with plug for connection between the Master/Slave terminals. Refer to the figure shown below and note the correct polarity when making the connection.
14 A R A R M U N I T C - A L 8 0 C-AL80 5x12 S-tight screw (supplied with MB-23B) Fiber washer (supplied with MB-23B) supplied with MB-23B M4x12 binding head screw (supplied with MB-23B) 9. RA CK MOUNTING When mounting the C-AL80 Unit in an equipment rack, remove 4 plastic feet on the bottom plate and attach an optional MB-23B mounting bracket.
15 Cause • The supplied AC cord is not connected to the C-AL80 Unit's Power inlet and AC outlet. • The C-AL80 Unit is not correctly connected to the Remote Controller. • The C-AL80 Unit's Mode Selection switch is not set to "Alarm.
(L) : AC110 – 120 V, 50/60 Hz (H) : AC220 – 240 V, 50/60 Hz 3 W(60 mA) 6 W(60 mA) 32 channels, no-voltage make contact input, open voltage : 5V DC, short-circuit current : max.
Een belangrijk punt na aankoop van elk apparaat TOA Electronics C-AL80(H) (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen TOA Electronics C-AL80(H) heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens TOA Electronics C-AL80(H) vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding TOA Electronics C-AL80(H) leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over TOA Electronics C-AL80(H) krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van TOA Electronics C-AL80(H) bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de TOA Electronics C-AL80(H) kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met TOA Electronics C-AL80(H) . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.