E6581295 ⑥ TOSVERT VF-AS1/PS1 Option Instruction Manual DEV002Z-1 * The data given in this manual are subject to change without notice. © Toshiba Schneider Inverter Corporation 2005 All rights reserved. NOTICE 1. Make sure that this instruction manual is delivered to the end user of the DeviceNet option for the VF-AS1/PS1.
E6581295 ⑥ - 1 - Safety precautions On the inverter and in its instruction m anual, important information is contained for preventing injuries to users and damages to assets and for proper use of the device.
E6581295 ⑥ - 2 - ■ General Operation Danger Disassembly prohibited ▼ Never disassemble, modify or repair. Doing so could result in electric shock, fire and injury. For repairs, call your sales agency. Prohibited ▼ Do not attach this option to any inverter other than the VF-AS1/PS1.
E6581295 ⑥ - 3 - ■ Wiring Danger Mandatory ▼ Shut off power when installing and wiring this option. Wait at least 15 minutes and check to make sure that the charge lamp (VF-AS1/PS1) is no longer lit. ▼ Tighten the screws on the terminal block to t he specified torque (Refer to Section 4.
E6581295 ⑥ - 4 - Introduction Thank you for purchasing a “VF-AS1/PS1 DeviceNet Option (DEV002Z),” for TOSVERT VF-AS1/PS1 inverter. Installing this option in the VF-AS1/PS1 and using it together, data communication can be made with a host computer or other device via DeviceNet.
E6581295 ⑥ - 5 - Contents 1. OVERVIEW .................................................................................................................... ..........................6 2. EXTERIOR FEATURES .............................................
E6581295 ⑥ - 6 - 1. Overview The DEV002Z interface allows the VF-AS1/PS1 inverter to be connected into a DeviceNet network. DeviceNet supports a maximum of 64 nodes, allowing for the Master unit and the configuration tool a maximu m of 62 devices can be connected to the network.
E6581295 ⑥ - 7 - 2. Exterior features The external view of this option and the name of each part are shown below: Danger Prohibited ▼ Do not change the switch setting when the power is on. It could lead to electric shocks, or the option might breaks down or get damaged.
E6581295 ⑥ - 8 - 2.2. DeviceNet indicator The DEV002Z option has a two-color (red and green) LED as a means of indicating the MNS (module/network status), which works basically in accordance with DeviceNet specifications. LED Status Item displayed Off Not Powered/Not On–line Device is not on-line.
E6581295 ⑥ - 9 - 3. Installing the DEV002Z Install the DeviceNet option to VF-AS1/PS1 as f ol lows : * When this option is used together with the IO card option, attach this option to the fr ont panel side. (1) Turn off input power of VF-AS1/PS1 and wait for at least 15 minutes and then check that the CHARGE lamp on VF-AS1/PS1 is no longer lit.
E6581295 ⑥ - 10 - 4. Connecting to the network 4.1. Installation method (1) Attach DeviceNet cable to DeviceNe t connector. (Refer to Section 2.1). (Be careful not to short-circuit adjacent terminals on DeviceNet connector). <Recommended cable> Thin branch cables: Device Net-specific thin cable.
E6581295 ⑥ - 11 - 4.2. Network Grounding Please note the following points regarding the grounding of a DeviceNet network. - Do not connect the G/E terminal to a power ground or any other potential noise-producing ground connection (such as a driv e’s “E” terminal).
E6581295 ⑥ - 12 - 4.3. Setting a MAC ID number and a network baud rate Configure MAC ID and network baud rate by the dip switch on the DeviceNet option . • MAC ID configuration The MAC ID must be unique and not matc h any other device on the network.
E6581295 ⑥ - 13 - 5. Communications-related parameters On the network, the VF-AS1/PS1 (including the DEV002Z) serves as a slave device. Using the parameters listed below, set the slave device on the net work and its mode of operation. These settings can also be made by the use of configuration tools and the EDS file.
E6581295 ⑥ - 14 - 5.1. f851 : Communication Loss Action Setting (Network breaks) This parameter sets up the VF-AS1/PS1 res ponse to a loss of communications with the DeviceNet network. 0: Stop and Communication release The inverter decelerates the motor to a stop and gives an alarm (the leftmost LED flashes).
E6581295 ⑥ - 15 - 5.3. f830 : Assembly Object Setting The Input/Output Instance of DEV002Z is set up by this parameter. The DEV002Z supports both the standard Device Net AC Drive profile Instances 20/70, 21/71 and user defined Inst ances 100/150, 101/151, 102/152.
E6581295 ⑥ - 16 - Data composition of output instance 100 Byte bit Specifications 0 1 Supplement 0 0 Preset speed #1* 1 0 1 Preset speed #2* 1 0 2 Preset speed #3* 1 0 3 Preset speed #4* 1 Preset sp.
E6581295 ⑥ - 17 - Data composition of output instance 150 Byte bit Specifications 0 1 Supplement 0 0 Fault FL No output Output - 0 1 Fault No trip Tripped The rtry status and the trip retention status are also regarded as tripped statuses.
E6581295 ⑥ - 18 - 6. DeviceNet Local/Remote Operation The example below shows how to configure t he VF-AS1/PS1 for local / remote operation. <Terminal function> F terminal ............ O perating command R terminal ............ Device Net/Local (Terminal in this example) switch ing RR/S4 terminal.
E6581295 ⑥ - 19 - 7. Specifications Item Specifications Model number DEV002Z DeviceNet Device type: AC drive Connector: Plug type Indicator: MNS (Module / Network status) MAC ID setup: DIP switch Ba.
Een belangrijk punt na aankoop van elk apparaat Toshiba DEV002Z (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Toshiba DEV002Z heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Toshiba DEV002Z vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Toshiba DEV002Z leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Toshiba DEV002Z krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Toshiba DEV002Z bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Toshiba DEV002Z kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Toshiba DEV002Z . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.