August, 1999 ICC #10207-000 “MICRO” A DJUSTA BLE SPEED DRIVE INTERFA CE MDB-100 MODBUS RTU / A SCII COMMUNICA TIONS INTERFA CE FOR THE TOSHIBA VF-S7 SERIES A DJUSTA BLE SPEED DRIVE.
1 Introduction Thank you f or purchasing t he ICC MDB-100 Modbus RTU / ASCII Comm unicat ions Interf ace f or the Toshiba VF-S7 Ser ies Micro Adjustable Speed Dr ive. Before using the MDB-100 interf ace, please familiar ize yourself with the product and be sure t o thoroug hly read the inst ructions and precaut ions cont ained in t his manual.
2 Usage Precautions • Please use the MDB-100 only when the ambient tem perature of the environm ent into which the MDB-100 is ins talled is within the following specif ied temper ature lim its: Oper.
3 TABLE OF CONTENTS 1. Interface Package Diagram .................................................................. 4 2. Feature Summary.................................................................................. 5 3. Installing The MDB-100 ....
4 1. Interf ace P ac k ag e Diag r am Note that t he above diag r am shows the MDB-100 with its cover removed. However, it is only necessary to remove the cover in or der t o initially config ure the MDB-100. Once conf ig ured, the cover should be r einst alled t o pr event damage and dust accumulation.
5 2. F ea tur e Summary The MDB-100 interf ace provides a wide array of network data access and dr ive control f eatures. Com bined with the f lexible data access methods and universal acceptance of t he Modbus network, t his allows powerful net worked control and monitoring system s t o be desig ned.
6 Programmable Pointer Regist ers 32 progr am m able point er register s ar e pr ovided for user def inition. By using t hese register s, f req uent ly-accessed dr ive paramet er s that may be scatter ed t hr oughout the register m ap can be g rouped tog et her and accessed with a single holding reg ist er read or write comm and.
7 3. Installing T he MDB-100 The MDB-100 connects to each drive via the drive’s communication por t , located on the right -hand side of t he drive enclosure under a small snap-on cover.
8 6. Repeat steps 1, 2, 4 and 5 above to connect anot her drive to Channel B on the MDB-100, if desired. 7. Remove the cover of the MDB-100 by removing the 4 cover screws. 8. Config ure the Modbus network character istics such as baud r at e, parity etc.
9 4. Equipment Specifica tions Item Specif ication Operating Environment Indoors, less t han 1000m above sea level, do not expose to direct sunlight or corrosive / explosive gasses Operating Temper at.
10 6. Stor ag e And W arr anty 6.1 Storage Observe the f ollowing points when the MD B-100 interf ace is not used imm ediat ely aft er pur chase or when it is not used f or an extended period of time. • Avoid storing the MDB-100 in places that ar e hot or humid, or t hat cont ain large quantit ies of dust or m et allic dust.
11 7. Netw or k Char acteristics Configura tion The MDB-100 interf ace board uses an 8-position DI P switch (labeled SW 1) t o config ure the Modbus network communication char act er ist ics.
12 A Note A bout Modbus Communi cation Formats Accordi ng to the Modicon Modbus Protocol Reference Guide , t he specificat ions f or both Modbus ASCII and RTU comm unication modes are as f ollows: A SCII Mod e Coding System: .
13 8. Modb us Sta tion Addr ess Selection The MDB-100 interf ace provides two diff er ent methods f or conf ig uring t he node’s station address. O ne m ethod uses the inverter num ber par am eter r.
14 Hold ing Register Wri t e Dat a Meaning 0x5A5A Reset the MDB-100 0xFEBA Reset the MDB-100 and return MDB-100 config uration reg isters to f actory def ault values.
15 9. Modicon Pr og ra mming 9.1 Supported Modbus Commands The MDB-100 interf ace supports 5 Modbus commands: comm and 1 ( 0x01: read coil status), com m and 3 ( 0x03: read holding reg isters), com m and 5 ( 0x05: f orce sing le coil), comm and 6 ( 0x06: pr eset sing le register ) and command 16 (0x10: pr eset multiple reg isters).
16 data will be the data obtained f rom reg isters 0xFE03, 0xFE04, 0xFE06, and 0xFD00 (in that order ) . Note that t he set t ings of t he pr og rammable address r egisters (0x6000 ∼ 0x601F) are stored in the MDB-100’s nonvolatile EEPROM. Ther ef ore, do not write t o any of these reg ister s m ore than 100,000 t imes.
17 For setting 2 (coast stop) , the drive will coast stop (f r ee run) if it was running. T his action clears bit #10 in the select ed drive’s communication comm and bit st r uct ure (reg ister 0x7A00 / 0xFA00 - also the same data as write-only coil #10 / #26) and set s bit #11 (same as coil #11 / #27).
18 The response delay time r value is read only upon MDB-100 initialization, req uiring the unit to be r eset if t he value is changed f or t he new value to tak e ef f ect . This setting is also non- volatile ( writt en t o t he MDB-100’s EEPROM). T her ef ore, do not write to this reg ister more t han 100, 000 times.
19 10. Modbus Pr ogr amming Interface 10.1 Overview Three t ypes of Modbus data may be accessed via the MDB-100. These are holding register s ( 4x reference) , r ead-only coils (0x reference) and write- only coils (0x ref er ence) .
20 Figure 2: MDB- 100 Hol di ng Register Mappi ng Dr i ve A Co m m . Nu m b e rs M DB- 100 H oldin g R e gi s t e r Ma p Dr i ve B Co m m . Nu m b e rs FFFF F0 0 0 D r ive B regi ster s FFFF F0 0 0 EF.
21 Table 1: Holding Regist er M appi ng General Overview Register # Name / Function Factory Setting Adj ustment Range 0000 ∼ 05FF Access d riv e A -- -- 6000 ∼ 601F Non-volatile program m able poi.
22 Sections 10.2 to 10. 4 specif y the communicat ion num ber → holding regist er mappings and coil def initions f or all current VF- S7 communication number s.
23 the MDB-100 does not place any restrictions on coils mark ed as “Reserved”. These coils may be written to at any time. The data or f unction associated with these coils is entirely defined by the connect ed dr ive.
24 10.2 Holding Registers Drive Reg. # (hex) Title Function M ax (hex:dec) Min (hex:dec) Run Mode Modify A B 0000 8000 AU1 Automa tic accelera tion and deceleration tim e 1 0 Yes A B 0001 8001 AU2 Aut.
25 Drive Reg. # (hex) Title Function M ax (hex:dec) Min (hex:dec) Run Mode Modify A B 0023 8023 Sr6 Preset speed 6 UL LL Yes A B 0024 8024 Sr7 Preset speed 7 UL LL Yes A B 0100 8100 F100 Low speed signal output frequenc y FH 0:0.0 Yes A B 0101 8101 F101 Speed reac h signal output frequenc y FH 0:0.
26 Drive Reg. # (hex) Title Function M ax (hex:dec) Min (hex:dec) Run Mode Modify A B 0241 8241 F241 Run f requency FH 0:0.0 Yes A B 0242 8242 F242 Run f requency hy ster esis FH 0:0.
27 Drive Reg. # (hex) Title Function M ax (hex:dec) Min (hex:dec) Run Mode Modify A B 0292 8292 F292 Pres et speed 13 UL LL Yes A B 0293 8293 F293 Pres et speed 14 UL LL Yes A B 0294 8294 F294 Pres et speed 15 UL LL Yes A B 0300 8300 F300 PW M c arrier fr equency (kHz) * 16:2.
28 Drive Reg. # (hex) Title Function M ax (hex:dec) Min (hex:dec) Run Mode Modify A B 0505 8505 F505 Ac celeration & deceler ation pattern #1 & #2 switching frequenc y UL 0:0.
29 Status Monitori ng Par ameter s (read-only) Drive Comm # (hex) Function A B 7D00 FD00 Current output fr equency A B 7E00 FE00 Output Frequency (saves trip frequenc y ) A B 7E01 FE01 Status (saves t.
30 Trip Data C odes Displa y Da ta Trip Ty pe nErr 0000 No trip OC1 0001 Overcurr ent dur ing acceleration OC2 0002 Overcurr ent dur ing deceleration OC3 0003 Overcurr ent dur ing constant-speed r un .
31 10.3 Write-Only Coils Coil # S7 A SD Function OFF ON 31 Comm and s ource Local Network 30 Frequenc y c omm and sourc e Local Network 29 Fault reset N/A Reset 28 Emergency OFF com m and N/A Tr ip .
32 10.4 Read-Only Coils Coil # S7 A SD Function OFF ON 131 Drive B online / off line status Offline Online 130 Reserved Alway s “0” 129 Reserved Alway s “0” 128 Reserved Alway s “0” 127 Re.
33 11. Notes.
34.
35.
36.
2202 Ti m berlo ch P lace, Suite 210 The Woodl ands, TX USA 773 80-1163 Tel: [281 ] 367 -3007 Fax: [281] 367-2177 W orl d Wide Web h ttp: //www.i ccdesi gns.
Een belangrijk punt na aankoop van elk apparaat Toshiba MDB-100 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Toshiba MDB-100 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Toshiba MDB-100 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Toshiba MDB-100 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Toshiba MDB-100 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Toshiba MDB-100 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Toshiba MDB-100 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Toshiba MDB-100 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.