TIC-LF494B Field Intelligent Device Series Sanitary Electromagnetic Flowmeter Introduction Sanitary electromagnetic flowmeters LF490 series are designed for applications ha ndling food and beverages.
TIC-LF494B 2 Specifications Overall Specifications Measurement range in terms of flow velocity: 0 –1.0 ft/s to 0 – 32.8 ft/s (0 – 0.3 m/s to 0 –10 m/s ) 0 – 0.3 ft/s to 0 – 1.0 ft/s (0 – 0.1 m/s to 0 – 0.3 m/s) range is available optionally.
TIC-LF494B 3 Model LF610 and LF612 converters Input signals Analog signal — the voltage signal from detector, proportional to process flow rate (for LF612 separate type converter). Digital input DI (opt.) Signal type: 20 to 30Vdc voltage signal Input resistance: 2.
TIC-LF494B 4 • Digital output: OFF • LCD display: No display • PROFIBUS: No communication Power supply: One of the following can be selected: • 100 to 240Vac, 50/60Hz (std.
TIC-LF494B 5 Installation Dimensions (Combined type) Clamp connection Unit : inch(mm) ØD1 L1 8.86( 225) 5 .63( 143) 1.42 ( 36 ) 5.16 ( 131 ) (L 2 ) Note1: Clamp (Joi nt) size i s different from m eter size of LF490 and LF494. See the following tab le.
TIC-LF494B 6 Dimensions (Separate type) Clamp connection 3 .4 6 ( 88 ) 3.58 ( 91 ) ( 単位 :mm ) ΦD1 L1 4.96 ( 126 ) 1.57 ( 40 ) (L2) R ( PT ) 1/ 2 M a l e sc r e w 1.38 ( 36 ) Note1: Clam p (Joint) size is different from meter size of LF490. See the following table.
TIC-LF494B 7 LF490, LF494 Detectors Pipe (weld ing) Normal type For English unit Meter size (inch) Joint size (ISO2852) L1 (inch) L2 (inch) D1 (inch) D2 (inch) D3 (inch) Weight (lbs ) 1 (1S) 2 S 0.85 0.11 2.52 0.91 1.00 Approx.0.4 1-1/2 (1-1/2S) 2 1/2 S 0.
TIC-LF494B 8 矢視 A 信号ケーブ ル グラ ン ド 電源ケーブ ルグラ ン ド 封止栓 励磁 ケーブ ルグラ ン ド 電流出力ケ ー ブルグ ラ ンド 接地端子 (M 4 ) 取付金具 4- φ 11 取付金具 82 (36 ) 1 5 6 13 15 1 17 8 20 0 151 74 ± 0 .
TIC-LF494B 9 T erm inal bo ard Conne cte d dete ctor IV wire 5.5 mm 2 or more Power switch (Ex ter nal do ubl e- pol e powe r sw itch ) Thi ck w alle d ste el cond uit Si gn al ca b le Pow er cabl e (.
TIC-LF494B 10 Wiring Precautions (1) Explosion proof type flowme ters are not provided cable glands. Refer to the part Cable connection port at detector and converter. (2) Connect the grounding wire (IV wire 5.5mm² or more) to a good earth ground (10 0 Ω or less ground resistance).
TIC-LF494B 11 Calibration Range If the calibration range is not specified, the standard range as shown below will be used. If the range is specified, we will use the specified range for calibration. Table 4. Standard Flow Range Standard flow range Meter size inch(mm) Flow rate (gal/min) Flow rate (m³/h) Flow velocity (m/s) 1 (25) 75 6 3.
TIC-LF494B 12 Table 5. Specification Code (Sanitary type detector LF490 Series) Model Specification Code Type 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Description Normal Ex.
TIC-LF494B 13 Table 6. Specification Code for converters Model Specific ation Code 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Contents LF600 type LF602 type L F 6 1 Electromagne tic flowmeter converter 0 Combin.
TIC-LF494B 14 This Page Intentionally Blank.
TIC-LF494B 15 This Page Intentionally Blank.
TIC-LF494B TIC-LF494B Specifications are subject to change without notice. Printed in Japan 2008-5 (TDOC) © TOSHIBA Corporation 2008 All Rights Reserved. http://www.toshiba.com/ind/ ISO9001 and ISO1400 1 are certified. Misuse of this product can result in damages to property or hum an injury.
Een belangrijk punt na aankoop van elk apparaat Toshiba TIC-LF494B (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Toshiba TIC-LF494B heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Toshiba TIC-LF494B vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Toshiba TIC-LF494B leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Toshiba TIC-LF494B krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Toshiba TIC-LF494B bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Toshiba TIC-LF494B kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Toshiba TIC-LF494B . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.