Gebruiksaanwijzing /service van het product VMH10TNB van de fabrikant Vanguard Heating
Ga naar pagina of 28
Save this manual for future reference. VENT -FREE NA TURAL GAS COMP ACT CLASSIC HEAR TH ® FIREPLACE OWNER’S OPERA TION AND INST ALLA TION MANUAL ® Shown with Optional Cabinet Mantel/Hearth Base Ac.
2 107031 VENT -FREE NA TURAL GAS COMP ACT FIREPLACE VMH10TNB ® SAFETY INFORMA TION Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the fireplace may not be working properly.
3 107031 OWNER’S MANUAL PRODUCT IDENTIFICA TION LOCAL CODES Install and use fireplace with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANS Z223.1 , also known as NFPA 54*. *Available from: American National Standards Institute, Inc.
4 107031 VENT -FREE NA TURAL GAS COMP ACT FIREPLACE VMH10TNB ® ASSEMBL Y ASSEMBLING FIREPLACE Tools Required: • Phillips screwdriver • 5/16" hex wrench • slotted screwdriver • scissors Installing Log 1. Lift screen up and pull out to remove.
5 107031 OWNER’S MANUAL AIR FOR COMBUSTION AND VENTILA TION Today’s homes are built more energy effi- cient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in.
6 107031 VENT -FREE NA TURAL GAS COMP ACT FIREPLACE VMH10TNB ® DETERMINING FRESH-AIR FLOW FOR FIREPLACE LOCATION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space.
7 107031 OWNER’S MANUAL AIR FOR COMBUSTION AND VENTILA TION Continued Figure 5 - Ventilation Air from Inside Building Shown with Optional Mantel VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space.
8 107031 VENT -FREE NA TURAL GAS COMP ACT FIREPLACE VMH10TNB ® CAUTION: If you install the fireplace in a home garage • fireplace pilot and burner must be at least 18 inches above floor.
9 107031 OWNER’S MANUAL Figure 8 - Mounting Clearances As Viewed From Front of Fireplace Shown with Op- tional Mantel Top Of Mantel Can Be Flush With Wall Left Side CEILING Right Side 36" Minimum INST ALLA TION Continued Continued 36 5/8" 25 7/8" 51 3/4" 26 7/8" Figure 10 - Rough Opening for Installing in Corner 1.
10 107031 VENT -FREE NA TURAL GAS COMP ACT FIREPLACE VMH10TNB ® 13" 16" 19" 21" 2 1 /2" 6" 8" 10" Note: All vertical measurements are from top of fireplace opening to bottom of mantel shelf. All measurements are in inches.
11 107031 OWNER’S MANUAL Assembling Brass Trim (Brass trim shipped with mantel) 1. Remove packaging from three remain- ing pieces of brass trim. 2. Locate two adjusting plates with set screws, and two shims in the hardware packet. 3. Align shim under adjusting plate as shown in Figure 15.
12 107031 VENT -FREE NA TURAL GAS COMP ACT FIREPLACE VMH10TNB ® 4. Carefully disconnect green and white wires at their insulated connectors. 5. In top of the heater cabinet, locate the four mounting holes on the outer cas- ing. Align these four holes with those on the blower bracket assembly .
13 107031 OWNER’S MANUAL For Built-In Installation WARNING: A licensed elec- trician must connect the wiring harness to electrical supply fol- lowing all local codes. Electri- cian must provide a clamp on the box cover to secure the wir- ing. Wiring should be routed through the bushing in the hole on the outer casing of heater.
14 107031 VENT -FREE NA TURAL GAS COMP ACT FIREPLACE VMH10TNB ® CONNECTING TO GAS SUPPLY WARNING: A qualified ser- vice person must connect fire- place to gas supply. Follow all local codes. IMPORTANT: Check gas line pressure be- fore connecting fireplace to gas line.
15 107031 OWNER’S MANUAL INST ALLA TION Continued Figure 24 - Removing Log Base Assembly From Fireplace CONNECTING FIREPLACE TO GAS SUPPLY Installation Items Needed • Phillips screwdriver • sealant (resistant to propane/L P gas, not provided) 1.
16 107031 VENT -FREE NA TURAL GAS COMP ACT FIREPLACE VMH10TNB ® ON POSITION OFF POSITION Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect appliance with its appliance main gas valve (control valve) and equip- ment shutoff valve from gas supply pip- ing system.
17 107031 OWNER’S MANUAL CAUTION: Do not try to adjust heating levels by using the equip- ment shutoff valve. Figure 29 - Pilot (Actual Pilot May Vary From Illustration) OPERA TING FIREPLACE FOR YOU.
18 107031 VENT -FREE NA TURAL GAS COMP ACT FIREPLACE VMH10TNB ® TO TURN OFF GAS TO APPLIANCE Thermostat Control Operation The thermostat used on this fireplace senses the room temperature. At times the room may exceed the set tempera- ture. If so, the burner will shut off.
19 107031 OWNER’S MANUAL BURNER FLAME PATTERN Figure 33 shows a correct burner flame pattern. Figure 34 shows an incorrect burner flame pattern. The incorrect burner flame pattern shows the flame consistently higher than one inch above the log.
20 107031 VENT -FREE NA TURAL GAS COMP ACT FIREPLACE VMH10TNB ® TROUBLESHOOTING POSSIBLE CAUSE 1. Ignitor cable pinched or wet 2. Ignitor electrode not connected to ignitor cable 3. Broken ignitor cable 4. Bad piezo ignitor 5. Ignitor electrode broken 6.
21 107031 OWNER’S MANUAL OBSERVED PROBLEM Burner does not light after ODS/pilot is lit Delayed ignition of burner Burner backfiring during combustion Slight smoke or odor during initial operation Fireplace produces a whistling noise when burner is lit White powder residue forming within burner box or on adjacent walls or furniture REMEDY 1.
22 107031 VENT -FREE NA TURAL GAS COMP ACT FIREPLACE VMH10TNB ® TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building.
23 107031 OWNER’S MANUAL CLEANING AND MAINTENANCE CABINET Air Passageways • Use a vacuum cleaner or pressurized air to clean. Exterior • Use a soft cloth dampened with a mild soap and water mixture. W ipe the cabi- net to remove dust. WARNING: Turn off fireplace and let cool before cleaning.
24 107031 VENT -FREE NA TURAL GAS COMP ACT FIREPLACE VMH10TNB ® ILLUSTRA TED PA R T S BREAKDOWN VMH10TNB 23 28 31 8 35 37 13 14 3 8 32 11 10 4 7 29 1 3 2 3 42 9 17 19 6 22 30 21 40 27 38 38 16 15 18 .
25 107031 OWNER’S MANUAL P ARTS LIST VMH10TNB This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 26 of this manual. KEY VMH10TNA NO. PART NO. DESCRIPTION QTY.
26 107031 VENT -FREE NA TURAL GAS COMP ACT FIREPLACE VMH10TNB ® SPECIFICA TIONS REPLACEMENT PA R T S Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty. PARTS UNDER WARRANTY Contact authorized dealers of this product.
27 107031 OWNER’S MANUAL ACCESSORIES Purchase these fireplace accessories from your local dealer. If they cannot supply these accessories call DESA International’s Sales Department at 1-800-458-2472 for referral information. You can also write to the ad- dress listed on the back page of this manual.
2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.desatech.com 107031-01 REV. A 03/00 INTERNA TIONAL LIMITED WARRANTY VENT-FREE NATURAL GAS COMPACT CLASSIC HEARTH ® FIREPLACE DESA.
Een belangrijk punt na aankoop van elk apparaat Vanguard Heating VMH10TNB (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Vanguard Heating VMH10TNB heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Vanguard Heating VMH10TNB vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Vanguard Heating VMH10TNB leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Vanguard Heating VMH10TNB krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Vanguard Heating VMH10TNB bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Vanguard Heating VMH10TNB kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Vanguard Heating VMH10TNB . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.