Gebruiksaanwijzing /service van het product VMH3000TPS van de fabrikant Vanguard Heating
Ga naar pagina of 24
Save this manual for future reference. VENT -FREE PROP ANE/LP GAS MINI-HEAR TH ® HEA TER OWNER’S OPERA TION AND INST ALLA TION MANUAL VMH3000TPS Shown With Optional Mantel Which Features a Built-In Base This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes.
2 106056-01 GAS RESIDENTIAL HEA TERS ® LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANS Z223.1 , also known as NFPA 54*. *Available from: American National Standards Institute, Inc.
3 106056 OWNER’S MANUAL PRODUCT IDENTIFICA TION Figure 1 - Vent-Free Gas Log Propane/LP Gas Space Heater UNP ACKING 1. Remove heater from carton. 2. Remove all protective packaging ap- plied to heater for shipment. 3. Make sure your heater includes two hardware packets.
4 106056-01 GAS RESIDENTIAL HEA TERS ® Attaching Brass Front Trim to Front Panel 1. Locate brass front trim in brass trim package. 2. Slide the head of two truss-head screws from hardware packet into each end of brass front trim (see Figure 5). 3. Line up screws with holes in front panel (see Figure 4).
5 106056 OWNER’S MANUAL AIR FOR COMBUSTION AND VENTILA TION Today’s homes are built more energy effi- cient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in.
6 106056-01 GAS RESIDENTIAL HEA TERS ® DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space.
7 106056 OWNER’S MANUAL VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must.
8 106056-01 GAS RESIDENTIAL HEA TERS ® WARNING: Never install the heater • in a bedroom or a bathroom • in a recreational vehicle • where curtains, furniture, clothing, or other flammable objec.
9 106056 OWNER’S MANUAL Thermostat Sensing Bulb Clamp THERMOSTAT SENSING BULB The thermostat sensing bulb has been placed inside the heater for protection during shipping. Locating Thermostat Sensing Bulb 1. Remove front panel of heater (see Fig- ure 2, page 3).
10 106056-01 GAS RESIDENTIAL HEA TERS ® Attaching To Wall Anchor Method For attaching mounting bracket to hollow walls (wall areas between studs) or solid walls (concrete or masonry) 1. Drill holes at marked locations using 5/16" drill bit. For solid walls (concrete or masonry), drill at least 1" deep.
11 106056 OWNER’S MANUAL INST ALLA TION Continued Mounting Heater to Optional Hearth Base 1. Lay heater on its back on a table with the bottom of heater overhanging the edge of the table. 2. Remove 2 shipping screws in bottom of heater . Discard shipping screws.
12 106056-01 GAS RESIDENTIAL HEA TERS ® Installation must include a manual shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up.
13 106056 OWNER’S MANUAL ON POSITION OFF POSITION CHECKING GAS CONNECTIONS Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect heater and its individual manual shutof f v alve from gas supply piping system.
14 106056-01 GAS RESIDENTIAL HEA TERS ® PILOT LO OFF HI IGNITOR OPERA TING HEA TER FOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS Figure 24 - Control Knob In The OFF Position Control Knob Ignitor Button 1. STOP! Read the safety inf ormation, column 1.
15 106056 OWNER’S MANUAL OPERA TING HEA TER Continued THERMOSTAT CONTROL OPERATION The thermostatic control used on this heater differs from standard thermostats. Standard thermostats simply turn on and off the burner. The thermostat used on this heater senses the room temperature.
16 106056-01 GAS RESIDENTIAL HEA TERS ® TROUBLESHOOTING WARNING: Turn off and un- plug heater and let cool before servicing. Only a qualified ser- vice person should service and repair heater. REMEDY 1. Replace ignitor 2. Replace ignitor 3. Reconnect ignitor cable 4.
17 106056 OWNER’S MANUAL REMEDY 1. Clean burner (see Cleaning and Mainte- nance , page 19) or replace burner orifice 2. Replace burner orifice 3. Contact local propane/LP company 1. Contact local propane/LP company 2. Clean burner (see Cleaning and Mainte- nance , page 19) or replace burner orifice 1.
18 106056-01 GAS RESIDENTIAL HEA TERS ® TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone.
19 106056 OWNER’S MANUAL CLEANING AND MAINTENANCE CABINET Air Passageways • Use a vacuum cleaner or pressurized air to clean. Exterior • Use a soft cloth dampened with a mild soap and water mixture. W ipe the cabi- net to remove dust. CAUTION: You must keep control areas, burner, and circu- lating air passageways of heater clean.
20 106056-01 GAS RESIDENTIAL HEA TERS ® 12-1 12-2 1 2 9 10 10 11 12 13 14 15 17 19 20 23 24 25 8 6 6 21 7 1 3 5 18 16 4 22 26 1 ILLUSTRA TED PAR TS BREAKDOWN VMH3000TPS.
21 106056 OWNER’S MANUAL P ARTS LIST VMH3000TPS This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 19 of this manual. KEY VMH3000TPS NO. PART NO. DESCRIPTION QTY.
22 106056-01 GAS RESIDENTIAL HEA TERS ® TECHNICAL SER VICE You may have further questions about in- stallation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-323-5190. You can also visit DESA International’s Technical Service web site at www.
23 106056 OWNER’S MANUAL MANUAL SHUTOFF VALVE GA5010 Manual shutoff valve with 1/8" NPT tap. HEARTH BASE - GHB802 SERIES For locating heater on the floor. Includes brass trim. Complete installation instruc- tions included. ACCESSORIES Purchase these heater accessories from your local dealer.
2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.desatech.com INTERNA TIONAL 106056-01 REV. A 06/99 LIMITED WARRANTY VENT-FREE PROPANE/LP MINI-HEARTH ® GAS HEATERS DESA Internati.
Een belangrijk punt na aankoop van elk apparaat Vanguard Heating VMH3000TPS (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Vanguard Heating VMH3000TPS heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Vanguard Heating VMH3000TPS vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Vanguard Heating VMH3000TPS leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Vanguard Heating VMH3000TPS krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Vanguard Heating VMH3000TPS bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Vanguard Heating VMH3000TPS kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Vanguard Heating VMH3000TPS . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.