1 THIS MANUAL CONT AINS IMPORT ANT INFORMA TION REGARDING SAFETY , OP- ERA TION, MAINTENANCE AND STORAGE OF THIS PRODUCT . BEFORE USING, READ AND UNDERST AND ALL CAUTIONS, W ARNINGS, INSTRUCTIONS AND PRODUCT LABELS, PLUS YOUR VEHICLE’S BA TTER Y MANUF ACTURER GUIDELINES.
2 Important Safety Instructions Read and understand all W arnings, Cautions and Notes before operating ElectroMate™. W arnings aler t the user to hazardous conditions that can cause personal injur y . Cautions aler t the user to conditions that can cause proper ty damage.
3 Contents 1. INTRODUCTION --------------------------------------------------------------- 4 2. GENERAL DESCRIPTION ----------------------------------------------- 5,6,7 2.1 Additional Key Features ---------------------------------------------- 7 2.2 Applications --------------------------------------------------------- 7,8 3.
4 1. INTRODUCTION Congratulations on selecting the V ector ElectroMate™ Model VEC097 Auxiliar y AC/DC Power System. ElectroMate is an advanced power and jump-star t system with unique features that set it far above the value and utility of ordinar y jump-star ters, portable tire compressors and auxiliar y AC and DC Power Supplies.
5 2. GENERAL DESCRIPTION This advanced system design is ideal for emergencies and can also enhance your fun by powering AC or DC appliances on the road, field location, in the garage and at the campsite. Please read this guide carefully before use to ensure best perfor mance and avoid damage to the system or items that you are using it with.
6 BA TTER Y CLAMPS CHARGER STORAGE HA TCH Jump-Star t Cables and Pr otection ElectroMate is equipped with extra heavy duty 78 inch (2 meters) long, 9mm 2 diameter cables and heavy duty clamps. The cable storage area and cables are shown in Figure 3. T o release clamps from unit squeeze handles.
7 For excellent light distribution, the light can be hooked onto the cross member of the extended handle. The fluorescent light can be completely removed from the Main Unit’ s storage channel and powered from any DC accessor y socket in vehicle, vessel or portable 12 volt DC supply .
8 NOTE: Other appliances may also be used with the ElectroMate as long as they do not exceed the 30 ampere DC limit of the units’ cigarette lighter type socket or the 1800 watt AC limit of the power inverter . Call V ector toll-free (866) 584-4446 for information on V ector AC and DC appliances.
9 4. USE AS A 12 VOL T DC POR T ABLE POWER SUPPL Y W ARNING: NEVER INSER T A CIGARETTE LIGHTER IN ELECTROMA TE’S ACCESSORY SOCKET . 1. Lift up the cover of one of the 12 V olt DC Accessor y Sockets. 2. Insert the 12 VOLT DC plug from the appliance into the Accessor y Socket.
10 simulates a shor t to ground and pops the breaker . This turns of f the outlets. Pressing the RESET button allows the outlets to turn on and provide power . Use with Appliances Make sure the AC appliance can operate on 110/120 V olts, 60 Hz AC modified sine wave (MSW) as most appliances sold in the USA can.
11 5.3 Operating Time V ector recommends that the operator recharge the batter y system as frequently as possible using the supplied VEC077EM Batter y Charger . This will guard against any unexpected shutdown of the equipment and will ensure that there is always sufficient batter y capacity .
12 AIR HOSE COOLING F AN DC PLUG ANALOG PRESSURE GAUGE ON/OFF SWITCH TIRE CHUCK DC CORD STORAGE HA TCH SAFE - Do not use the inverter near flammable materials or in any location that may accumulate flammable fumes or gases. The switch and clamp connections can cause sparks.
13 6.1 Compressor Use IMPORT ANT : Read Instructions carefully to avoid possible injur y or proper ty damage. The Compressor may be used by removing the air hose from it’ s storage channel and fitting the tire chuck to the tire or inflatable. An On/Off switch located on the compressor controls the power .
14 6.5 Inflating Items Without a a Tire Stem Three inflation adapters are stored in the compressor’ s DC Cord Storage Hatch. Select and connect the appropriate adapter to the compressor’ s tire chuck. Insert the adapter into the item to be inflated.
15 8.1 AC Recharge Recharge requires the use of the supplied VEC077EM Automatic Batter y Charger . The charger must be powered from a 110 volt AC, 60 Hz North American standard household AC receptacle. T ypical recharge time is ten hours CAUTION: NEVER OPERA TE THE VEC077EM CHARGER FROM ELECTROMA TE’S POWER INVERTER.
16 T o check the batter y status, press the Batter y Status Display Push-button. If the Jump-Starter’ s batter y is fully discharged, it is recommended that the host vehicle or boat’ s engine being used for recharging be left operating while the unit is being charged using the 12 V olt DC/DC method.
17 11. Specifications: Jump-Star t Clamps ..................................................... 400 Amps - Heavy Duty Copper Jumper Cables ........................................................................... 9mm 2 W elding Cable Batter y ......
18 Appendix B Extending Operating Time Longer operating time can be realized by connecting ElectroMate to an exter- nal batter y . The external batter y will combine the Ampere Hour hour ratings of connected batteries.
19 T r oubleshooting – Appendix C SYMPTOM POSSIBLE CAUSE CORRECTIVE ACTION Inverter Alarm Sounds Low battery voltage Check Batter y Level Display and recharge batter y if low Inverter will not operate Batter y below 10.
20 © 2002 VECTOR MANUF ACTURING, Ltd. FT . LAUDERDALE, FL 33312 MADE IN CHINA 1 YEAR LIMITED W ARRANTY REGISTRA TION FORM This V ector Manufacturing, Ltd. product is warranted, to the original purchaser only , to be free of defects in materials and workmanship for One Y ear from the date of purchase without additional charge.
Een belangrijk punt na aankoop van elk apparaat Vector ElectroMate VEC097 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Vector ElectroMate VEC097 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Vector ElectroMate VEC097 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Vector ElectroMate VEC097 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Vector ElectroMate VEC097 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Vector ElectroMate VEC097 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Vector ElectroMate VEC097 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Vector ElectroMate VEC097 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.