Gebruiksaanwijzing /service van het product 3030 van de fabrikant Vermont Castings
Ga naar pagina of 26
Tested and listed to ANSI Z21.11.2a-2001, Unvented Heaters This is an unvented gas-fired heater. It uses air (Oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer to Page 7. UVS27R, UVS27M V ent Free Gas Heaters Models 3030, 3031, 3032, 3033 20005004 10/04 Rev .
2 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 Installation and Operating Instructions Shell Dimensions ............................................................................................................... 4 Clearance Requirements ..
3 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 Installation & Operating Instructions In order to ensure safe and effective installation, this unit must be installed only by a qualified age.
4 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 Shell Dimensions Drawing Not to Scale Fig. 1 UVS27 freestanding shell dimensions. C L C L 9" (229mm) 26 ³⁄₄ " (680mm) 25" (63.
5 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 Hearth Requirements The Freestanding Stove and Hearthmount Shell must be installed on rigid flooring.
6 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 Gas Specifications Max. Min. Input Input Mode l Fuel Gas Cont rol BT U /h BT U /h UVS27RN Nat Milli volt 2 8, 00 0 19,500 UVS27RP Prop Millivol t 28,000 19,500 UVS27MN Nat Millivolt 28,000 19,500 UVS27MP Prop Millivolt 28,000 19,500 Firebox weight / shipping 1 10 lbs.
7 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 Pr ovide For Adequate V entilation Any space within a home can be classified in the following categories: 1) Unusually Tight Construction 2) Confined Space 3) Unconfined Space First, determine which classification defines the intended space.
8 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 Example: A room that is 18' x 12' x 8' has a volume of 1728 cubic feet, ( length x width x height). An adjoining open kitchen that is 10' x 12' x 8' has a volume of 960 cubic feet.
9 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 Assembly Procedures Refer to the specific assembly instructions for the shell appropriate to your UVS27R or UVS27M Heater installation.
10 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 Screw & W asher Support Shelf Back Panel Side Plate ST106 Fig. 7 The sides must be at right angles to the back panel in order for the firebox to fit properly . ST125 Firebox washer align 10/15/99 djt Steel T ab Side Plate ST125 Fig.
11 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 ST346 Fig. 12 Attach snapstat to inner shroud. Rheostat Retaining Nut Control Knob FK104 Fig. 13 Attach rheostat to bracket. ST345 Fig. 11 Correct position of fan skirt installation. Install ON/OFF Switch The switch assembly parts are found in the parts bag.
12 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 Glass & Catalyst Installation CA UTION: Air shutter on Natural Gas units must be adjusted when installing glass and catalyst for proper operation. LP units do not use an air shutter . 1. Remove screen.
13 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 90¡ Left Burner Leg Injector Orifices ST353a Fig. 20 Be sure injector orifices remain at 90 ° to the base. shoulders are inside the burner . 5. Replace rear , left and right log bracket assembly and replace logs.
14 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 Install Log Set 1. Remove the logs from their packaging, and inspect each piece for damage. DO NO T INST ALL DAM- AGED LOGS. 2. Install the rear log by placing it on the sheet metal shelf at the back of the firebox.
15 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 Complete the Installation 1. Install the screen frame by sliding the hooks over the top front edge of the firebox and resting the bottom on the support brackets.
16 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 Operation Your First Fire Read these instructions carefully and familiarize yourself with the burner controls shown on Page 18. Locate the pilot assembly, Figure 28. Follow the lighting instructions on Page 17 exactly.
17 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 3. Open control access panel. 4. Push in gas control knob slightly and turn clockwise to "OFF". Do not force. 5. Close control access panel. 1. STOP! Read the safety information above. 2.
18 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 Tr oubleshooting Follow these procedures in the order presented. W ARNING TURN OFF HEA TER AND ALLO W T O COOL COMPLETEL Y BEFORE SER VICING. CONDITION POSSIBLE CAUSE SOLUTION No spark at pilot when Ignitor is operated.
19 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 Tr oubleshooting cont’ d. CONDITION POSSIBLE CAUSE SOLUTION Pilot lights but flame goes out when Control Knob is released. 1. Control Knob not fully depressed or held in long enough. 2. Gas supply line shut-of f valve is not fully open.
20 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 The following procedures will help ensure that your heater continues to perform safely and efficiently. Firebox Cleaning and Inspection Cleanliness is critical to correct operation of the heater.
21 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 Catalytic Combustor The combustor should be cleaned annually to ensure optimal performance. Follow the procedure below. Remove the Combustor Module 1. Be sure the heater is COLD. 2. Remove the top grille, screen and top plate.
22 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 PILO T O N O F F PILOT ADJ L O H I TPTH TH TP 1a 1b 1c 2a,b 6 8 5 21 19 20 4 11 12 13 7 15 9a,b 18 22 3 16a,b,c,d 10a 10b 14a,b 17 1d HI OFF PIL.
23 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 UVS27R, UVS27M V ent Free Gas Heater s Models 3030, 3031, 3032, 3033 (continued) Ref. Description UVS27 2a. Manifold Assy . - UVS27R 20003739 2b. Manifold Assy . - UVS27M 20004935 3. Damper Steel Handle/Screw (Stardance Operable Door Only) 5004265 4.
24 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 UVS27R, UVS27M V ent Free Gas Heater s Models 3030, 3031, 3032, 3033 (continued) Shell Enamel Part Numbers - Hearthmount Color T op Left End Rig.
25 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 Optional Accessories A vailab le Fan Kits FK28 Fan Assemb ly The FK28 fan kit helps distribute heated air from within the firebox out into the room. The fan is controlled by a snapstat that turns power on and off as the firebox temperature rises above and falls below a preset temperature.
26 Vermont Castings UVS27 Vent-Free Gas Heater 20005004 © CFM Specialty Home Products BASIC WARRANTY CFM Specialty Home Products (hereinafter referred to collectively as the Company) warrants that yo.
Een belangrijk punt na aankoop van elk apparaat Vermont Castings 3030 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Vermont Castings 3030 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Vermont Castings 3030 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Vermont Castings 3030 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Vermont Castings 3030 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Vermont Castings 3030 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Vermont Castings 3030 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Vermont Castings 3030 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.